Reset-OVEnclosureDevice
Syntax
Reset-OVEnclosureDevice
[-InputObject] <Object>
[-Component] <String>
[-DeviceID] <Int32>
[-Efuse]
[-Async]
[-ApplianceConnection <Object>]
[<CommonParameters>]
Reset-OVEnclosureDevice
[-InputObject] <Object>
[-Component] <String>
[-DeviceID] <Int32>
[-Reset]
[-Async]
[-ApplianceConnection <Object>]
[<CommonParameters>]
Description
This Cmdlet will assist server administrators in performing various power operations with HPE Synergy enclosure resources. The following resources are supported with their supported operation:
- HPE Synergy Appliance Bay - EFuse
- HPE Synergy Frame Link Module - EFuse or Reset
- Device Bay - EFuse or Reset
- HPE Synergy Fabric Module Device - EFuse
E-Fuse stands for Electronic Fuse. Setting the power state of a device to "E-Fuse" (or "Reset" for an Enclosure Manager) will reset the bay, but it will soon return to a normal running state. An E-Fuse will turn off power to the bay and then turn it back on. If the bay was powered off before the E-Fuse operation it will be powered on afterwards. A "Reset" will do a hard reset of the bay without affecting the power. E-Fuse on a device bay will power-cycle the whole blade including the iLO.
A reset on the active Synergy Frame Link Module causes a failover to the standby Synergy Frame Link Module. The reset will fail if the Synergy Frame Link Module's firmware is being updated. An E-Fuse against an active Synergy Frame Link Module is not allowed.
Info
Minimum required privileges: Infrastructure administrator, Server administrator
Examples
Example 1
$Enclosure = Get-OVEnclosure -Name Enclosure1 -ErrorAction Stop
Reset-OVEnclosureDevice -Enclosure $Enclosure -Component FLM -DeviceID 1 -EFuse
Reset the FLM in slot 1 by performing an EFuse.
Example 2
$Enclosure = Get-OVEnclosure -Name Enclosure1 -ErrorAction Stop
Reset-OVEnclosureDevice -Enclosure $Enclosure -Component ICM -DeviceID 3 -EFuse
Reset the ICM in interconnect bay 3 by performing an EFuse.
Example 3
$Task = Get-OVEnclosure -Name Enclosure1 -ErrorAction Stop | Reset-OVEnclosureDevice -Component Device -DeviceID 4 -Reset
Reset the device in bay 4 by requesting it to reset itself.
Example 4
$Task = Get-OVEnclosure -Name Enclosure1 -ErrorAction Stop | Reset-OVEnclosureDevice -Component Appliance -DeviceID 1 -EFuse
Reset the appliance device in bay 1 by performing an EFuse.
Parameters
-InputObject <Object>
The Synergy Frame resource from Get-OVEnclosure.
| Aliases | Enclosure |
|---|---|
| Required? | True |
| Position? | Named |
| Default value | |
| Accept pipeline input? | true (ByValue) |
| Accept wildcard characters? | False |
-Component <String>
The embedded component to perform the action against. Allowed value:
- FLM - Frame Link Module. Both EFuse and Reset are supported.
- Appliance - Management Appliance; Synergy Compser or Synergy Image Streamer. Only supported method is EFuse.
- ICM - Synergy Fabric Interconnect Module. Only supported method is EFuse.
- Device - Synergy Device (e.g. Compute Node populated in Bay 1). Both EFuse and Reset are supported.
| Aliases | None |
|---|---|
| Required? | True |
| Position? | Named |
| Default value | |
| Accept pipeline input? | false |
| Accept wildcard characters? | False |
-DeviceID <Int32>
The corrisponding bay ID.
| Aliases | None |
|---|---|
| Required? | True |
| Position? | Named |
| Default value | 0 |
| Accept pipeline input? | false |
| Accept wildcard characters? | False |
-Reset <SwitchParameter>
Reset power to the device. Only supported with certain component types.
| Aliases | None |
|---|---|
| Required? | False |
| Position? | Named |
| Default value | False |
| Accept pipeline input? | false |
| Accept wildcard characters? | False |
-Efuse <SwitchParameter>
EFuse will take away and then present power back to the device. Supported with all component types.
| Aliases | None |
|---|---|
| Required? | False |
| Position? | Named |
| Default value | False |
| Accept pipeline input? | false |
| Accept wildcard characters? | False |
-Async <SwitchParameter>
Use this parameter to immediately return the async task. By default, the Cmdlet will wait for the task to complete.
| Aliases | None |
|---|---|
| Required? | False |
| Position? | Named |
| Default value | False |
| Accept pipeline input? | false |
| Accept wildcard characters? | False |
-ApplianceConnection <Object>
Specify one or more [HPEOneView.Appliance.Connection] object(s) or Name property value(s).
Default Value: ${Global:ConnectSessions}
| Aliases | Appliance |
|---|---|
| Required? | True |
| Position? | Named |
| Default value | (${Global:ConnectedSessions} | ? Default) |
| Accept pipeline input? | true (ByPropertyName) |
| Accept wildcard characters? | False |
-WhatIf <SwitchParameter>
| Aliases | wi |
|---|---|
| Required? | False |
| Position? | Named |
| Default value | |
| Accept pipeline input? | false |
| Accept wildcard characters? | False |
-Confirm <SwitchParameter>
| Aliases | cf |
|---|---|
| Required? | False |
| Position? | Named |
| Default value | |
| Accept pipeline input? | false |
| Accept wildcard characters? | False |
<CommonParameters>
This cmdlet supports the common parameters: Verbose, Debug, ErrorAction, ErrorVariable, WarningAction, WarningVariable, OutBuffer, PipelineVariable, and OutVariable. For more information, see about_CommonParameters (http://go.microsoft.com/fwlink/?LinkID=113216)
Input Types
Resource from Get-OVEnclosure.
Return Values