Introduction
The iLO RESTful API for HPE iLO 6 is a programming interface enabling state-of-the-art server management. This document contains helpful information about how to interact with the iLO RESTful API. The iLO RESTful API uses the basic HTTP operations (GET, PUT, POST, DELETE, and PATCH) to submit or return a JSON formatted resource to or from a URI on iLO 6.
With modern scripting languages, you can easily write simple REST clients for RESTful APIs. Most languages, like Python, can transform JSON into internal-data structures, like dictionaries, allowing for easy access to data. This enables you to write custom code directly to the iLO RESTful API, instead of using intermediate tools such as HPE’s HPQLOCFG or CONREP.
Redfish Conformance
iLO 6’s Redfish conformance details are available in this document in the Managing Hewlett Packard Enterprise Servers Using the RESTful API.
Key benefits of the iLO RESTful API
The iLO RESTful API is becoming the main management interface for Hewlett Packard Enterprise servers with iLO 6. Its feature set will become larger than the existing iLO XML API (RIBCL) and IPMI interfaces. Using the iLO RESTful API, you can take full inventory of the server, control power and reset, configure BIOS and iLO settings, fetch event logs, as well as many other functions.
The iLO RESTful API follows the trend of the Internet in moving to a common pattern for new software interfaces. Many web services in a variety of industries use REST APIs because they are easy to implement, easy to consume, and offer scalability advantages over previous technologies.
HPE OneView, OpenStack, and many other server management APIs are now REST APIs. Most Hewlett Packard Enterprise Management software offerings, as well as the entire Software Defined Infrastructure, are built upon REST APIs.
The iLO RESTful API has the additional advantage of consistency across all present and projected server architectures. The same data model works for traditional rack-mount servers, blades, as well as newer types of systems. This advantage comes because the data model is designed to self-describe the service’s capabilities to the client and has room for flexibility designed in from the start.
Changelog
The HPE iLO 6 Redfish service implements the DMTF Redfish specification version 1.6.0 and the schemas implemented by iLO 6 adhere to the DMTF Redfish schema bundle 8010_2021.4.
For a better understanding of the conformance to the DMTF Redfish, read the Redfish versioning paragraph of this article.
iLO 6 v1.50 new features and changes
New URIs
- No new URIs added in this release.
HTTP methods - additions and deprecations
- No changes have been made to HTTP methods in this release.
Deprecated URIs
- No URIs deprecated in this release.
Redfish actions - additions and deprecations
- No changes have been made to supported Redfish Actions for this release.
Schema updates
AccountService.v1_5_0.AccountService
- Added
Oem.Hpe.TwoFactorAuth
: This property indicates whether two factor authentication is enabled or not.
- Added
ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
- Added
Oem.Hpe.SMTPForTFAEnabled
: Indicates whether SMTP for Two Factor Authentication is enabled.
- Added
iLO 6 v1.45 new features and changes
New URIs
- No new URIs added in this release.
HTTP methods - additions and deprecations
- No changes have been made to HTTP methods in this release.
Deprecated URIs
- No URIs deprecated in this release.
Redfish actions - additions and deprecations
redfish/v1/ComponentIntegrity/{@ComponentIntegrity}
- Added
ComponentIntegrity.SPDMGetSignedMeasurements
: This action gets the SPDM Signed Measurements. The following parameters are added: Nonce
(string) : A set of bytes as a hex-encoded string that is signed with the measurements. The value should be unique.Target
(string): Link to invoke actionTitle
(string) : Friendly action nameSlotId
(integer): The slot identifier for the certificate containing the private key to generate the signature over the measurements.MeasurementIndices
(array): An array of indices that identify the measurement blocks to sign.- Added
ComponentIntegrity.TPMGetSignedMeasurements
: This action gets the TPM Signed Measurements.The following parameters are added: Nonce
(string) : A set of bytes as a hex-encoded string that is signed with the measurements. The value should be unique.Target
(string): Link to invoke actionTitle
(string) : Friendly action nameSlotId
(integer): The slot identifier for the certificate containing the private key to generate the signature over the measurements.MeasurementIndices
(array): An array of indices that identify the measurement blocks to sign.
- Added
Schema updates
#ComponentIntegrity.v1_2_0.ComponentIntegrity
- Added
SPDM.MeasurementSet
Measurements
array has the following values:LastUpdated
: The date and time when information for the measurement was last updated.Measurement
: The measurement data.MeasurementHashAlgorithm
: The hash algorithm used to compute the measurement.MeasurementIndex
: The index of the measurement.MeasurementType
: Supports the following values;ImmutableROM
,MutableFirmware
,HardwareConfiguration
,FirmwareConfiguration
,MutableFirmwareVersion
,MutableFirmwareSecurityVersionNumber
,MeasurementManifest
SecurityVersionNumber
: The security version number the measurement represents.
- Added
TPM
TPM.ComponentCommunication.Sessions
:SessionId
: The identifier for an active session or communication channel between two components.SessionType
:Plain
,EncryptedAuthenticated
andAuthenticatedOnly
are the supported values
- Added
TPM.MeasurementSet.Measurements
:LastUpdated
: The date and time when information for the measurement was last updated.Measurement
: The measurement data.MeasurementHashAlgorithm
: The hash algorithm used to compute the measurement.PCR
: The Platform Configuration Register (PCR) bank of the measurement.NonceSizeBytesMaximum
: The maximum number of bytes that can be specified in the Nonce parameter of the TPMGetSignedMeasurements action.
- Added
#ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
- Added
Oem.Hpe.KcsEnabled
: Indicates whether KCS interface is enabled or disabled for the BMC.
- Added
iLO 6 v1.40 new features and changes
New URIs
- No new URIs added in this release.
HTTP methods - additions and deprecations
- No changes have been made to HTTP methods in this release.
Deprecated URIs
- No URIs deprecated in this release.
Redfish actions - additions and deprecations
- Added POST for
redfish/v1/ComponentIntegrity/{@ComponentIntegrity}
Schema updates
#ComponentIntegrity.v1_0_0.ComponentIntegrity
updated to#ComponentIntegrity.v1_2_0.ComponentIntegrity
#HpeComponentInstallSet.v1_1_0.HpeComponentInstallSet
updated to#HpeComponentInstallSet.v1_2_0.HpeComponentInstallSet
#HpeComponentUpdateTask.v1_2_0.HpeComponentUpdateTask
updated to#HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
#HpeiLOSnmpService.v2_3_0.HpeiLOSnmpService
updated to#HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
- Added
SNMPv1RequestsEnabled
andSNMPv1TrapEnabled
to indicate if the SNMPv1 Queries and SNMPv1 Traps are enabled respectively. - Added
SNMPv3RequestsEnabled
andSNMPv3TrapEnabled
to indicate if the SNMPv3 Queries and SNMPv3 Traps are enabled respectively.
- Added
#Memory.v1_14_0.Memory
- MemoryList
- Added
BoardMemoryType
toMemoryCollection
. The memory collection now lists HBM memory as members, in supported Gen11 servers.
#SessionService.v1_0_0.SessionService
- Added
SessionTimeout
: This is the number of seconds of inactivity that a session may have before the session service closes the session. Here the value0
means no timeout or infinite timeout.
- Added
iLO 6 v1.35 new features and changes
New URIs
- No new URIs added in this release.
HTTP methods - additions and deprecations
- No changes have been made to HTTP methods in this release.
Deprecated URIs
- No URIs deprecated in this release.
Redfish actions - additions and deprecations
- No changes have been made to supported Redfish Actions for this release.
Schema updates
#HpeSecurityService.v2_3_1.HpeSecurityService
updated to#HpeSecurityService.v2_4_0.HpeSecurityService
iLO 6 v1.30 new features and changes
New URIs
- No new URIs added in this release.
HTTP methods - additions and deprecations
- No changes have been made to HTTP methods in this release.
Deprecated URIs
- No URIs deprecated in this release.
Redfish actions - additions and deprecations
- No changes have been made to supported Redfish Actions for this release.
Schema updates
#HpeServerPCISlot.v2_1_1.HpeServerPCISlot
updated to#HpeServerPCISlot.v2_2_0.HpeServerPCISlot
- Added
SegmentNumber
: Depicts PCI slot segment group number value.
- Added
#MemoryChunks.v1_2_3.MemoryChunks
- Added
Unsupported
as a property underOem.Hpe.AmpModeStatus
- Added
#SoftwareInventory.v1_2_0.SoftwareInventory
- Added
Oem.Hpe.Version
- Added
iLO 6 v1.20 new features and changes
New URIs
- No new URIs added in this release.
HTTP methods - additions and deprecations
- Added PATCH for
redfish/v1/Chassis/{@chassisId}/PCIeDevices/{@PCIeDeviceId}}
- Deprecated POST for
/redfish/v1/systems/{item}/secureboot/securebootdatabases
Deprecated URIs
- No URIs deprecated in this release.
Redfish actions - additions and deprecations
No changes have been made to supported Redfish Actions for this release.
Schema updates
#Drive.v1_14_0.Drive
HotspareType
:Read-only
updated toFalse
.
#EventDestination.v1_0_0.EventDestination
updated to#EventDestination.v1_12_0.EventDestination
- Added
SubscriptionType
: The subscription type for events.RedfishEvent
is the supported value.
- Added
#HpeServerPciDevice.v2_0_0.HpeServerPciDevice
updated to#HpeServerPciDevice.v2_1_0.HpeServerPciDevice
- Added
DeviceResourceId
: PCI device resource ID or hash ID.
- Added
PCIeDevice.v1_5_0.PCIeDevice
- Added
AssetTag
: The user-assigned asset tag for this PCIe device.
- Added
#Signature.v1_0_0.Signature
updated to#Signature.v1_0_2.Signature
#Storage.v1_12_0.Storage
- Added
Actions
: AddedStorage.ResetToDefaults
, an action to reset the system. - Added
Parameters
: The following parameters have been added :ResetType
,target
andtitle
.
- Added
#Thermal.v1_7_1.Thermal
- Added
Oem.Hpe.MainSensorName
toTemperatures
: Sensor name of main temperature sensor that has atleast one sub sensor.
- Added
iLO 6 v1.10 new features and changes
New URIs
/redfish/v1/ComponentIntegrity
(GET, PATCH)#ComponentIntegrityCollection.ComponentIntegrityCollection
- A Collection of ComponentIntegrity resource instances./redfish/v1/ComponentIntegrity/{@ComponentIntegrity}
(GET)#ComponentIntegrity.v1_0_0.ComponentIntegrity
- The ComponentIntegrity resource provides critical and pertinent security information about a specific device, system, software element, or other managed entity.ComponentIntegrityEnabled
: Indicates whether security protocols are enabled for the component.ComponentIntegrityType
: The property is of type string that supports the following values:SPDM
- Security Protocol and Data Model (SPDM) protocol,TPM
- Trusted Platform Module (TPM), andOEM
- OEM-specific.ComponentIntegrityTypeVersion
: The version of the security technology.SPDM
(Security Protocol and Data Module): The status of the verification of the identity of the component.Success
andFailure
are the supported values. Added the following properties:SPDM.IdentityAuthentication
,SPDM.IdentityAuthentication.ResponderAuthentication
, andSPDM.IdentityAuthentication.ResponderAuthentication.VerificationStatus
toSPDM
.TargetComponentURI
: The link to the the component whose integrity that this resource reports.
#CertificateCollection.CertificateCollection
- A Collection of Certificate resource instances. The following resource instances are added in this schema:/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/KEK/Certificates
(GET, POST)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/KEKDefault/Certificates
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/PK/Certificates
(GET, POST)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/PKDefault/Certificates
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/db/Certificates
(GET, POST)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbDefault/Certificates
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbr/Certificates
(GET, POST)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbrDefault/Certificates
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbt/Certificates
(GET, POST)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbtDefault/Certificates
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbx/Certificates
(GET, POST)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbxDefault/Certificates
(GET)
#Certificate.v1_1_0.Certificate
updated to#Certificate.v1_6_0.Certificate
: The Certificate resource describes an X509 certificate. The following resource instances are added in this schema:/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/KEK/Certificates/{@CertificateId}
(GET, DELETE)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/KEKDefault/Certificates/{@CertificateId}
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/PK/Certificates/{@CertificateId}
(GET, DELETE)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/PKDefault/Certificates/{@CertificateId}
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/db/Certificates/{@CertificateId}
(GET,DELETE)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbDefault/Certificates/{@CertificateId}
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbr/Certificates/{@CertificateId}
(GET, DELETE)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbrDefault/Certificates/{@CertificateId}
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbt/Certificates/{@CertificateId}
(GET, DELETE)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbtDefault/Certificates/{@CertificateId}
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbx/Certificates/{@CertificateId}
(GET, DELETE)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbxDefault/Certificates/{@CertificateId}
(GET)
#SignatureCollection.SignatureCollection
: A collection of Signature resource instances. The following resource instances are added in this schema:/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/db/Signatures
(GET, POST)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbDefault/Signatures
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbr/Signatures
(GET, POST)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbrDefault/Signatures
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbt/Signatures
(GET, POST)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbtDefault/Signatures
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbx/Signatures
(GET, POST)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbxDefault/Signatures
(GET)
#Signature.v1_0_0.Signature
: The Signature schema describes a signature or a hash.- Added
SignatureString
: The string for the signature. - Added
SignatureType
: The format of the signature. - Added
SignatureTypeRegistry
:UEFI
(a signature defined in the UEFI Specification) is the supported value. - Added
UefiSignatureOwner
: The UEFI signature owner for the signature. The following resource instances are added in this schema: /redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/db/Signatures/{@SignatureId}
(GET,DELETE)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbDefault/Signatures/{@SignatureId}
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbr/Signatures/{@SignatureId}
(GET,DELETE)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbrDefault/Signatures/{@SignatureId}
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbt/Signatures/{@SignatureId}
(GET,DELETE)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbtDefault/Signatures/{@SignatureId}
(GET)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbx/Signatures/{@SignatureId}
(GET,DELETE)/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/dbxDefault/Signatures/{@SignatureId}
(GET)
- Added
/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases
(GET,POST)#SecureBootDatabaseCollection.SecureBootDatabaseCollection
- A collection of SecureBootDatabase resource instances.#SecureBootDatabase.v1_0_0.SecureBootDatabase
: The SecureBootDatabase schema describes a UEFI Secure Boot database used to store certificates or hashes.- Added
Certificates
: A link to the collection of certificates contained in the UEFI Secure Boot database. - Added
DatabaseId
: The property contains the name of the UEFI Secure Boot database. - Added
Signatures
: A link to the collection of signatures contained in the UEFI Secure Boot database. - Added
Actions
: SecureBootDatabase.ResetKeys
: Action to perform reset of the Secure Boot Database Keys.- Added
Parameters
: - Added
ResetKeysType (string)
(the parameter specifies what type of reset action to perform). The values areDeleteAllKeys
(delete all Secure Boot Database keys on next boot) andResetAllKeysToDefault
(reset to default Secure Boot Database keys on next boot).
- Added
/redfish/v1/Systems/{@systemsId}/SecureBoot/SecureBootDatabases/{@SecureBootDatabaseId}
(GET, DELETE)/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/PK
(GET)/redfish/v1/systems/{item}/secureboot/securebootdatabases/db
(GET)/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbdefault
(GET)/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr
(GET)/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault
(GET)/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt
(GET)/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault
(GET)/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx
(GET)/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault
(GET)/redfish/v1/systems/{item}/secureboot/securebootdatabases/kek
(GET)/redfish/v1/systems/{item}/secureboot/securebootdatabases/kekdefault
(GET)/redfish/v1/systems/{item}/secureboot/securebootdatabases/pkdefault
(GET)
/redfish/v1/Systems/{@systemId}/LogServices/DPU/Entries
(GET,POST) #LogEntryCollection.LogEntryCollection
- A Collection of LogEntry resource instances.
/redfish/v1/Systems/{@systemId}/LogServices/DPU/Entries/{@entriesId}
(GET,PATCH) #LogEntry.v1_11_0.LogEntry
- Defines the record format of a log.
/redfish/v1/Systems/{@systemId}/Storage/{@storageId}/Controllers/{@StorageControllerId}
(GET) #StorageController.v1_0_0.StorageController
: Describes a storage controller and its properties. The storage controller represents a physical or virtual storage device that produces volumes.
/redfish/v1/systems/{item}/ethernetinterfaces/{item}
(GET,PATCH,POST) #EthernetInterface.v1_4_1.EthernetInterface
:The EthernetInterface resource describes a single, logical ethernet interface or network interface controller (NIC).
/redfish/v1/managers/{item}/backuprestoreservice
(GET,PATCH) #HpeiLOBackupRestoreService.v2_2_0.HpeiLOBackupRestoreService
: The HpeiLOBackupRestoreService resource describes the properties for using the BMC backup and restore features.
HTTP methods - additions and deprecations
No changes have been made to HTTP methods in this release.
Deprecated URIs
BaseNetworkAdapters
deprecated/redfish/v1/systems/{item}/basenetworkadapters/{item}
NetworkPorts
deprecated/redfish/v1/Chassis/{@ChassisId}/NetworkAdapters/{@nicId}/NetworkPorts
/redfish/v1/Chassis/{@ChassisId}/NetworkAdapters/{@nicId}/NetworkPorts/{@portId}
/redfish/v1/Chassis/{@ChassisId}/NetworkAdapters/{@nicId}/NetworkPorts/{@portId}/HpeEVB
/redfish/v1/Chassis/{@ChassisId}/NetworkAdapters/{@nicId}/NetworkPorts/{@portId}/HpeLLDP
/redfish/v1/Chassis/{@ChassisId}/NetworkAdapters/{@nicId}/NetworkPorts/{@portId}/Settings
/redfish/v1/Systems/{@systemsId}/NetworkInterfaces/{@nicId}/NetworkPorts
/redfish/v1/Systems/{@systemsId}/NetworkInterfaces/{@nicId}/NetworkPorts/{@portId}
/redfish/v1/Systems/{@systemsId}/NetworkInterfaces/{@nicId}/NetworkPorts/{@portId}/HpeEVB
/redfish/v1/Systems/{@systemsId}/NetworkInterfaces/{@nicId}/NetworkPorts/{@portId}/HpeLLDP
/redfish/v1/Systems/{@systemsId}/NetworkInterfaces/{@nicId}/NetworkPorts/{@portId}/Settings
For more information, refer to (Deprecated for iLO 6)
Redfish actions - additions and deprecations
No changes have been made to supported Redfish Actions for this release.
Schema updates
#Certificate.v1_1_0.Certificate
updated to#Certificate.v1_6_0.Certificate
- Added
Issuer
andSubject
: City
: The city or locality of the organization of the entity.CommonName
: The fully qualified domain name of the entity.Country
: The country of the organization of the entity.DisplayString
: A human-readable string for this identifier.Email
: The email address of the contact within the organization of the entity.Organization
: The name of the organization of the entity.OrganizationalUnit
: The name of the unit or division of the organization of the entity.State
: The state, province, or region of the organization of the entity.
- Added
#Chassis.v1_10_2.Chassis
updated to #Chassis.v1_19_2.Chassis
- Deprecated
IndicatorLED
: A fall back is provided in theComputerSystem
schema, for clients who want to continue usingIndicatorLED
. - Added
LocationIndicatorActive
: An indicator allowing an operator to physically locate this resource. This property replacesIndicatorLED
and is in-line with the updated DMTF schema. - Added
EnvironmentalClass
: The ASHRAE Environmental Class for the chassis. The following are the supported values: A2 - ASHRAE Environmental Class ‘A2’, A3 - ASHRAE Environmental Class ‘A3’, and A4 - ASHRAE Environmental Class ‘A4’. - Added
Location.PartLocation
: LocationOrdinalValue
: The number that represents the location of the part. If LocationType isslot
and this unit is in slot 2, the LocationOrdinalValue is 2.LocationType
: The location types for PartLocation. The following are the supported values:Null
,Slot
,Bay
,Connection
,Socket
, andEmbedded
.Orientation
: The orientation for the ordering of the part location ordinal value. The following are the supported values:Null
,FrontToBack
,BackToFront
,TopToBottom
,BottomToTop
,LeftToRight
, andRightToLeft
.Reference
: The reference area for the location of the part. The following are the supported values:Null
,Top
,Bottom
,Front
,Rear
,Left
,Right
, andMiddle
.ServiceLabel
: The label of the part location, such as a silk-screened name or a printed label.
Location.Placement
: AdditionalInfo
: Area designation or other additional info.Rack
: The name of a rack location within a row.RackOffset
: The vertical location of the item, in terms of RackOffsetUnits.RackOffsetUnits
: The type of rack unit in use. he following are the supported values: Null
, OpenU
(a rack unit that is equal to 1.89 inches (48 mm)), and EIA_310
(a rack unit that is equal to 1.75 inches (44.45 mm).Row
: The name of the row.CpuMezzProgrammableLogicDevice
to Oem.Hpe.Firmware
: The firmware version of the CPLD (System Programmable Logic Device).Oem.Hpe.TelcoModeEnabled
: This property indicates if Telco mode is enabled on the server. #ComputerSystem.v1_10_0.ComputerSystem
updated to #ComputerSystem.v1_17_0.ComputerSystem
- Deprecated
IndicatorLED
- Added
Oem.Hpe.IndicatorLED
: The state of the indicator LED. The following are the supported values:Null
,Lit
,Blinking
andOff
. This is a fall back added for clients that want to continue to useIndicatorLED
- Added
LocationIndicatorActive
: An indicator allowing an operator to physically locate this resource. This property replacesIndicatorLED
and is in-line with the updated DMTF schema. - Added
BootProgress
: LastState
: SmartNIC device operating system status. The following are the supported values:OSBootStarted
,OSRunning
andOEM
.OemLastState
: SmartNIC device operating system oem status. The following are the supported values:OSServicesReady
,OSServicesOffline
,OSHalting
andOSHalted
.
Oem.Hpe.AvailableSystemCapabilities
: Indicates SmartNIC DPU supports OS-triggered DPC. OSTriggeredDPC
is the supported value.Oem.Hpe.BootProgress
: OemResetReason
: The Smart NIC Device Operating system OEM reset reason. The following are the supported values: Unknown
, OSNormal
, BMCNormal
, OSCrash
, HWWatchdog
and Thermal
.ResetReason
: The Smart NIC Device Operating system reset reason .The following are the supported values: OEM
, Unknown
, OSNormal
, BMCNormal
, OSCrash
, HWWatchdog
and Thermal
. Oem.Hpe.EnabledSystemCapabilities
: Indicates SmartNIC DPU supports OS-triggered DPC. OSTriggeredDPC
is the supported value.OsReadyTimeout
to Oem.Hpe.IntegrationConfig
.Kernel.Version
to Oem.Hpe.OperatingSystem
: SmartNIC device operating system kernel version.PowerState
: This is the current power state of the system. Added the following supported values: PoweringOn
and PoweringOff
.SystemType
: The type of computer system that this resource represents. DPU
is added to the supported values.ComputerSystem.SetSimpleUpdateStatus
: Added the following Parameters: Message (string)
: Message to be displayedTaskState (string)
: TaskState identifies the type of Action to be performed. The following are the supported values: New
, Starting
, Running
,Suspended
,Interrupted
,Pending
, Stopping
, Completed
, Killed
,Exception
and Service
.PercentComplete (integer)
: Percentage of task complete. TaskStatus (string)
: Current status of the ongoing task. The following are the supported values: Ok
, Warning
and Critical
. #Drive.v1_7_0.Drive
upgraded to Drive.v1_14_0.Drive
- Deprecated
IndicatorLED
- Added
Oem.Hpe.IndicatorLED
: The state of the indicator LED. The following are the supported values:Null
,Lit
,Blinking
andOff
. This is a fall back added for clients that want to continue to useIndicatorLED
- Added
LocationIndicatorActive
: An indicator allowing an operator to physically locate this resource. This property replacesIndicatorLED
and is in-line with the updated DMTF schema.
#HpeSecureEraseReport.v1_1_0.HpeSecureEraseReport
DeviceType
:PCIControllers
added as supported value.
#HpeSecurityService.v2_3_1.HpeSecurityService
- Added
ComponentIntegrityPolicy
:NoPolicy
andHaltBootOnSPDMFailure
are the supported values. - Added
GlobalComponentIntegrity
:Enabled
andDisabled
are the supported values. - Added the following to
TrustedOSSecurity
: EnableBackgroundScan
: Enables or disables background scan of host OS software.LastScanResult
: Health of the host after the last scan done by Trusted OS Security scan engine. The following are the supported values:OK
,Critical
,Unknown
.LastScanTime
: The time stamp of the last Trusted OS Security scan.OnIntegrityFailure
: Sets the policy for how the Trusted OS Security check handles integrity failures. The following are the supported values:NoAction
,Alert
,PowerOff
,PowerOffForce
,Reset
,ForceNMI
.ScanEverySeconds
: Sets the interval between Trusted OS Security scans in second increments.
#HpeServerDevice.v2_1_0.HpeServerDevice
- Added
FirmwareVersion
: ComponentName
: Name of GPU coresVersionString
: Version String of GPU cores
#LogService.v1_0_0.LogService
updated to LogService.v1_1_0.LogService
- Added
DateTime
: The current date and time, with UTC offset, that the Log Service uses to set or read time. - Added
DateTimeLocalOffset
: The UTC offset that the current DateTime proeprtu value contains in the+HH:MM
format. - Added
ServiceEnabled
: An indication of whether this service is enabled.
#Manager.v1_5_1.Manager
DateTime
:Read Only
updated toTRUE
iLOSelfTestResults[{item}].SelfTestName
following are the supported values:SecureElement
#Memory.v1_7_1.Memory
updated to #Memory.v1_14_0.Memory
- Added the value
DDR5
to the supported values inMemoryDeviceType
.
#NetworkAdapter.v1_5_0.NetworkAdapter
upgraded to #NetworkAdapter.v1_9_0.NetworkAdapter
- Added
Location.PartLocation
: LocationOrdinalValue
: The number that represents the location of the part. If LocationType isslot
and this unit is in slot 2, the LocationOrdinalValue is 2.LocationType
: The location types for PartLocation. The following are the supported values:Null
,Slot
,Bay
,Connector
,Socket
andEmbedded
.Orientation
: The orientation for the ordering of the part location ordinal value. The following are the supported values:Null
,FrontToBack
,BackToFront
,TopToBottom
,BottomToTop
,LeftToRight
andRightToLeft
.Reference
: The reference area for the location of the part. The following are the supported values:Null
,Top
,Bottom
,Front
,Rear
,Left
,Right
andMiddle
.ServiceLabel
: The label of the part location, such as a silk-screened name or a printed label.
Location.Placement
: AdditionalInfo
: Area designation or other additional info.Rack
: The name of a rack location within a row.RackOffset
: The vertical location of the item, in terms of RackOffsetUnits.RackOffsetUnits
: The type of rack unit in use. The following are the supported values: Null
, OpenU
and EIA_310
.Row
: The name of the row. Oem.Hpe.FcPorts
: is an array containing elements of: PortNumber
: Port NumberWWNN
: World Wide Node NameWWPN
: World Wide Port Name Oem.Hpe.PhysicalPorts
: BadReceives
: A count of frames that were received by the adapter but which had an error. This counter is the sum of mib items cpqNicIfPhysAdapterAlignmentErrors
, cpqNicIfPhysAdapterFCSErrors
, cpqNicIfPhysAdapterFrameTooLongs
, and cpqNicIfPhysAdapterInternalMacReceiveErrors
. If this counter increments frequently, check the more detailed error statistics and take appropriate action.BadTransmits
: A count of frames that were not transmitted by the adapter because of an error. This counter is the sum of MIB items cpqNicIfPhysAdapterDeferredTransmissions, cpqNicIfPhysAdapterLateCollisions, cpqNicIfPhysAdapterExcessiveCollisions, cpqNicIfPhysAdapterCarrierSenseErrors, and cpqNicIfPhysAdapterInternalMacTransmitErrors. If this counter increments frequently, check the more detailed error statistics and take appropriate action.FullDuplex
: Full-duplex data transmission means that data can be transmitted in both directions on a signal carrier at the same time.GoodReceives
: A count of frames successfully received by the physical adapter.GoodTransmits
: A count of frames successfully transmitted by the physical adapter.IPv4Addresses
: This is the IPv4 Address. The following value is added: Address
, LinkStatus
: The link status of this interface (port). The following are the supported values: LinkUp
,NoLink
,LinkDown
and Null
.MacAddress
: The port MAC address.SpeedMbps
: An estimate of the interface’s current bandwidth in Megabits per second. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth.StructuredName
:PCI device structured name in UTF-8 format (e.g. ‘NIC.LOM.1.1’ - see PCIDevices in /rest/v1/Systems/x/PCIDevices
)Team
: If a port is configured for NIC teaming, the name of the configured link between the physical ports that form a logical network adapter. This value is displayed for system NICs only (embedded and stand-up).UEFIDevicePath
: UEFIDevice Path for correlation purposes. #NetworkDeviceFunction.v1_5_0.NetworkDeviceFunction
updated to #NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
#PCIeDevice.v1_4_0.PCIeDevice
updated to #PCIeDevice.v1_5_0.PCIeDevice
- Added
Oem.Hpe.FirmwareVersion
: ComponentName
: Name of GPU coresVersionString
: Version string of GPU cores
#Port.v1_5_0.Port
updated to #Port.v1_6_1.Port
- Added
AssociatedWorldWideNames
toFibreChannel
#Power.v1_3_0.Power
- Added
Oem.Hpe.Domains
: DomainName
:Power Supply Domain Name. The following values are supported:System
andGPU
.HighEfficiencyMode
: The redundant power supply mode that will be used when redundant power supplies are configured. The following values are supported:Null
,Auto
,Balanced
,Even
,Odd
andNoSupport
.PowerSupplies
:PowerSupplies
is an array containing elements of:PowerSupplies[{item}].@odata.id
PowerSupplyRedundancy
: This indicates if the Power Supply is redundant or not. The following values are supported:Redundant
,NonRedundant
,FailedRedundant
andUnknown
.
Oem.Hpe.HighEfficiencyMode
: Added NoSupport
to supported values.PowerSupplies.Oem.Hpe.Domain
: This indicates the domain of the specific power supply. The following values are supported: System
and GPU
.Oem.Hpe.HighEfficiencyMode
: NoSupport
added as a supported value.#ServiceRoot.v1_5_1.ServiceRoot
updated to #ServiceRoot.v1_13_0.ServiceRoot
- Added
ComponentIntegrity
: The URI to the collection resource.
#Thermal.v1_7_1.Thermal
Temperatures[{item}].PhysicalContext
: Added the following enum values:LiquidInlet
,LiquidOutlet
,CPUSubsystem
,GPUSubsystem
,FPGA
,Accelerator
,ASIC
,PowerSubsystem
,Rectifier
,MemorySubsystem
,Chassis
,Fan
,CoolingSubsystem
,Motor
,Transformer
,ACUtilityInput
,ACStaticBypassInput
,ACMaintenanceBypassInput
,DCBus
,ACOutput
,ACInput
,TrustedModule
,Board
,Transceiver
,Battery
andPump
#UpdateService.v1_1_1.UpdateService
updated to #UpdateService.v1_2_1.UpdateService
#VirtualMedia.v1_2_0.VirtualMedia
updated to #VirtualMedia.v1_3_0.VirtualMedia
Adapting from iLO 5
This section is a guide to help client code adapt from the iLO 5 RESTful API to the iLO 6 RESTful API.
Introduction
The iLO 6 RESTful API is fully conformant with Redfish. Any remaining support for the pre-Redfish iLO RESTful API has been removed and is replaced by the Redfish equivalents. HPE continues to extend the Redfish data model to enable value for the customer.
Deprecated for iLO 6
BaseNetworkAdapters deprecated
From iLO 6 v1.10 onwards, the BaseNetworkAdapters
URI (Systems/1/BaseNetworkAdapters
and underlying resources) are deprecated. The corresponding properties are moved to the standard NetworkAdapter
API Chassis/1/NetworkAdapters
.
For iLO 6, Chassis/1/NetworkAdapters
will list all types of Nics such as DCi, RDE, and Non-RDE/Non-DCi BaseNetwork Adapters where Chassis/1/NetworkAdapters
used to list only DCi and RDE Nics until iLO 5.
The HpeBaseNetworkAdapter
(OEM) schema in iLO is no longer supported from iLO 6 v1.10 and all those properties are used as part of NetworkAdapter
(DMTF) schema, and a few properties as OEM
properties under Chassis/1/NetworkAdapters
.
Thus, the BaseNetwork Adapters will be listed under Chassis/1/NetworkAdapters
with ResourceId as Chassis/1/NetworkAdapters/DA******
.
NetworkAdapters Properties
/Actions
are not supported for BaseNetworkAdapters as below:
- All Write support (POST/PATCH) including ResetSettingsToDefault
, FlushConfigurationToNVM
, and so on are not supported.
- Links to NetworkDeviceFunctions
and NetworkPorts
are not supported as Ports
, Oem.Hpe.PhysicalPorts[]
and Oem.Hpe.FcPorts[]
list the port details.
S.No | Property under BaseNetworkAdapters | Property under NetworkAdapters | Standard/OEM under NetworkAdapters |
---|---|---|---|
1 | Name | Name | As per DMTF |
2 | Manufacturer | Manufacturer | As per DMTF |
3 | SerialNumber | SerialNumber | As per DMTF |
4 | PartNumber | PartNumber | As per DMTF |
5 | Location | Location.PartLocation.LocationType | As per DMTF |
Location.PartLocation.ServiceLabel | As per DMTF | ||
Location.PartLocation.LocationOrdinalValue | As per DMTF | ||
6 | Firmware.Current.VersionString | Controllers.FirmwarePackageVersion | As per DMTF |
Controllers.ControllerCapabilities.NetworkPortCount(count of PhysPort/FcPort | As per DMTF | ||
Controllers.PartLocation.LocationType | As per DMTF | ||
Controllers.PartLocation.ServiceLabel | As per DMTF | ||
Controllers.PartLocation.LocationOrdinalValue | As per DMTF | ||
7 | Status.Health | Status.Health | As per DMTF |
8 | Status.State | Status.State | As per DMTF |
9 | PhysicalPorts[].FullDuplex | Oem.Hpe.PhysicalPorts[].FullDuplex | OEM |
10 | PhysicalPorts[].IPv4Addresses[] | Oem.Hpe.PhysicalPorts[].IPv4Addresses[] | OEM |
11 | PhysicalPorts[].IPv6Addresses[] | Oem.Hpe.PhysicalPorts[].IPv6Addresses[] | OEM |
12 | PhysicalPorts[].LinkStatus | Oem.Hpe.PhysicalPorts[].LinkStatus | OEM |
13 | PhysicalPorts[].MacAddress | Oem.Hpe.PhysicalPorts[].MacAddress | OEM |
14 | PhysicalPorts[].Name | Oem.Hpe.PhysicalPorts[].Name | OEM |
15 | PhysicalPorts[].SpeedMbps | Oem.Hpe.PhysicalPorts[].SpeedMbps | OEM |
16 | PhysicalPorts[].BadReceives | Oem.Hpe.PhysicalPorts[].BadReceives | OEM |
17 | PhysicalPorts[].BadTransmits | Oem.Hpe.PhysicalPorts[].Transmits | OEM |
17 | PhysicalPorts[].GoodReceives | Oem.Hpe.PhysicalPorts[].GoodReceives | OEM |
18 | PhysicalPorts[].GoodTransmits | Oem.Hpe.PhysicalPorts[].GoodTransmits | OEM |
18 | PhysicalPorts[].Oem.Hpe.Team | Oem.Hpe.PhysicalPorts[].Team | OEM |
PhysicalPorts[].UEFIDevicePath | OEM | ||
PhysicalPorts[].StatusHealth | OEM | ||
PhysicalPorts[].StatusState | OEM | ||
19 | FcPorts[].PortNumber | Oem.hpe.FcPorts[].PortNumber | OEM |
FcPort[].WWNN | Oem.hpe.FcPort[].WWNN | OEM | |
FcPort[].WWPN | Oem.hpe.FcPort[].WWPN | OEM | |
20 | StructuredName | OEM.Hpe.StructuredName | OEM |
UEFIDevicePath | Oem.Hpe.UEFIDevicePath | OEM |
NetworkPorts deprecated
From iLO 6 v1.10 onwards, the NetworkPorts
URI and underlying resources are deprecated. The corresponding properties are moved to the standard Port
API as DMTF Redfish standard specification deprecates the NetworkPort.json
with the implementation of Port.json
.
Deprecated NetworkPorts
URIs:
/redfish/v1/Chassis/1/NetworkAdapters/1/NetworkPorts
/redfish/v1/Chassis/1/NetworkAdapters/1/NetworkPorts/1
/redfish/v1/Chassis/1/NetworkAdapters/1/NetworkPorts/1/HpeEVB
/redfish/v1/Chassis/1/NetworkAdapters/1/NetworkPorts/1/HpeLLDP
/redfish/v1/Chassis/1/NetworkAdapters/1/NetworkPorts/1/Settings
redfish/v1/Systems/1/NetworkInterfaces/1/NetworkPorts
/redfish/v1/Systems/1/NetworkInterfaces/1/NetworkPorts/1
/redfish/v1/Systems/1/NetworkInterfaces/1/NetworkPorts/1/HpeEVB
/redfish/v1/Systems/1/NetworkInterfaces/1/NetworkPorts/1/HpeLLDP
/redfish/v1/Systems/1/NetworkInterfaces/1/NetworkPorts/1/Settings
HPE Smart Storage Model (OEM) deprecated
HPE initially developed the SmartStorage
Redfish OEM data model for HPE ProLiant DL580 Gen 8 server. This model supported inventory (GET) and monitoring (Events) features.
In HPE ProLiant Gen 10, the SmartStorageConfig
resource was added to support configuration. This OEM model used a proprietary API that only supports the SR line of storage controllers. This OEM storage model is removed starting with iLO 6 / HPE ProLiant Gen 11 servers.
Customers are encouraged to use the open standard DMTF Redfish Storage Model.
The following OEM specific SmartStorageConfig
and SmartStorage
resources are removed in iLO 6/Gen 11:
HpeSmartStorage
HpeSmartStorageArrayController
HpeSmartStorageDiskDrive
HpeSmartStorageLogicalDrive
HpeSmartStorageStorageEnclosure
HpeSmartStorageHostBusAdapter
Detail of All Property Changes
Schemas Deprecated in iLO 6 v1.05
HpeBaseNetworkAdapter Deprecated
@odata.type: #HpeBaseNetworkAdapter.v2_0_0.HpeBaseNetworkAdapter
See BaseNetworkAdapters deprecated.
NetworkPort Deprecated
@odata.type: #NetworkPort.v1_2_5.NetworkPort
HpeNetworkPortEVB Deprecated
@odata.type: #HpeNetworkPortEVB.v1_2_0.HpeNetworkPortEVB
HpeNetworkPortLLDP Deprecated
@odata.type: #HpeNetworkPortLLDP.v1_2_0.HpeNetworkPortLLDP
HpeSmartStorage Deprecated
@odata.type: #HpeSmartStorage.v2_0_0.HpeSmartStorage
See HPE Smart Storage Model (OEM) deprecated.
Property Replacements and Removals
EthernetInterface Renames and Removals
@odata.type: #EthernetInterface.v1_4_1.EthernetInterface
Property | Replacement | Note |
---|---|---|
/Oem/Hpe/SharedNetworkPortOptions/NIC | Deprecated the supported values of OEM properties in the HpeiLOEthernetNetworkInterface schema. |
The following are the supported values: LOM (the LOM NIC is configured to be shared), FlexibleLOM (the FlexibleLOM NIC is configured to be shared.), and FlexibleLOM/OCP (the FlexibleLOM/OCP is configured to be shared.) |
/Oem/Hpe/SupportsFlexibleLOM | Deprecated the supported value of OEM property in HpeiLOEthernetNetworkInterface schema. |
None. |
/Oem/Hpe/SupportsLOM | Deprecated the supported value of OEM property in HpeiLOEthernetNetworkInterface schema. |
None. |
HpeSecureEraseReport Renames and Removals
@odata.type: #HpeSecureEraseReport.v1_0_0.HpeSecureEraseReport
Property | Replacement | Note |
---|---|---|
DeviceType/SmartStorage | Version deprecated in iLO 6 v1.05. | Deprecated the supported value SmartStorage . |
ServiceRoot Renames and Removals
@odata.type: #ServiceRoot.v1_13_0.ServiceRoot
Property | Replacement | Note |
---|---|---|
/Oem/Hpe/CACLoginUri | Deprecated OEM property. Deprecated in HpeiLOServiceExt schema. URI for the CAC based authentication. |
None. |
Thermal Renames and Removals
@odata.type: #Thermal.v1_7_1.Thermal
Property | Change | Note |
---|---|---|
/Temperatures/{item}/PhysicalContext | Deprecated a few supported values in Temperatures (array) in Temperatures[{item}]PhysicalContext. | None. |
Property Additions to existing Types
Certificate Additions
@odata.type: #Certificate.v1_1_0.Certificate
Property | Change | Note |
---|---|---|
/UefiSignatureOwner | Added in iLO 6 v1.05 | The UEFI signature owner for the certificate. |
Chassis Additions
@odata.type: #Chassis.v1_10_2.Chassis
Property | Change | Note |
---|---|---|
Oem/Hpe/Firmware/SecondarySystemProgrammableLogicDevice | Added OEM property (HpeServerChassis schema). Secondary Complex programmable logic device (CPLD). |
None. |
Oem/Hpe/Firmware/SecondarySystemProgrammableLogicDevice.Current | Added OEM property (HpeServerChassis schema). The current firmware version. |
None. |
Oem/Hpe/Firmware/SecondarySystemProgrammableLogicDevice.Current.VersionString | Added OEM property (HpeServerChassis schema). The firmware version of the CPLD. |
None. |
Oem/Hpe/TelcoModeEnabled | Added OEM property (HpeServerChassis schema). This property indicates if Telco mode is enabled on the server. |
None. |
ComputerSystem Additions
@odata.type: #ComputerSystem.v1_13_0.ComputerSystem
Property | Change | Note |
---|---|---|
Oem/Hpe/PostMode | Added the supported value PostToWait to OEM property (HpeComputerSystemExt ). Server boots until Discovery Completes, then indefinitely waits. |
None. |
EthernetInterface Additions
@odata.type: EthernetInterface.v1_4_1.EthernetInterface
Property | Change | Note |
---|---|---|
/Oem.Hpe.SharedNetworkPortOptions/NIC | Added OEM property supported values (HpeiLOEthernetNetworkInterface schema). |
Selects the system NIC that is to be shared with this management processor. The following are the supported values: OCP1 (the OCP1 NIC is configured to be shared), OCP2 (the OCP2 NIC is configured to be shared), and EmbeddedNIC (the EmbeddedNIC is configured to be shared). |
/Oem/Hpe/SupportsEmbeddedNIC | Added OEM property (HpeiLOEthernetNetworkInterface schema). Indicates whether this system supports LOM. Only applies to Shared Network Port. |
None. |
/Oem/Hpe/SupportsOCP1 | Added OEM property (HpeiLOEthernetNetworkInterface schema). Indicates whether the system supports OCP1. Only applies to Shared Network Port. |
None. |
/Oem/Hpe/SupportsOCP2 | Added OEM property (HpeiLOEthernetNetworkInterface schema). Indicates whether the system supports OCP2. Only applies to Shared Network Port. |
None. |
EventDestination Additions
@odata.type: #EventDestination.v1_0_0.EventDestination
Property | Change | Note |
---|---|---|
/RegistryPrefixes (array) | Version added iLO 6 v1.05. Replaces the older EventType based event subscription. The list of the prefixes of the message registries that can be used for the RegistryPrefix property on a subscription. If this property is absent or contains an empty array, the service does not support RegistryPrefix-based subscriptions. This property shall contain the array of the prefixes of the message registries that shall be allowed for an event subscription. | None |
EventService Additions
@odata.type: #EventService.v1_7_2.EventService
Property | Change | Note |
---|---|---|
/RegistryPrefixes (array) | Version added in iLO 6 v1.05. Replaces the older EventType based event subscription. The list of the prefixes of the message registries that can be used for the RegistryPrefix property on a subscription. If this property is absent or contains an empty array, the service does not support RegistryPrefix-based subscriptions. This property shall contain the array of the prefixes of the message registries that shall be allowed for an event subscription. | None |
HpeSecureEraseReport Additions
@odata.type: #HpeSecureEraseReport.v1_1_0.HpeSecureEraseReport
Property | Replacement | Note |
---|---|---|
DeviceType/PCIControllers | Version added in iLO 6 v1.05. | This indicates the device type is PCI Controllers . |
HpeServerDevice Additions
@odata.type: #HpeServerDevice.v2_1_0.HpeServerDevice
Property | Change | Note |
---|---|---|
/DeviceType/Embedded SATA Controller | Version added in iLO 6 v1.05. | Added supported value Embedded SATA Controller . |
Memory Additions
@odata.type: #Memory.v1_14_1.Memory
Property | Change | Note |
---|---|---|
/MemoryDeviceType/DDR5 | Version added in iLO 6 v1.05. | Added the supported value. The Memory resource describes a memory module. |
Port Additions
@odata.type: #Port.v1_6_1.Port
Property | Change | Note |
---|---|---|
/PortProtocol | Version added in iLO 6 v1.05 | The protocol being sent over this port. Added supported values. The following are the supported values:SAS - Serial Attached SCSI, MultiProtocol - Multiple Protocols, PCIe - PCI Express, AHCI - Advanced Host Controller Interface (AHCI), UHCI - Universal Host Controller Interface (UHCI), SATA - Serial AT Attachment, USB - Universal Serial Bus (USB), NVMe - Non-Volatile Memory Express (NVMe), iSCSI - Internet SCSI, FCP - Fibre Channel Protocol for SCSI, FICON - FIbre CONnection (FICON), NVMeOverFabrics - NVMe over Fabrics, SMB - Server Message Block (SMB). Also known as the Common Internet File System (CIFS), NFSv3 - Network File System (NFS) version 3, NFSv4 - Network File System (NFS) version 4, HTTP - Hypertext Transport Protocol (HTTP), HTTPS - Hypertext Transfer Protocol Secure (HTTPS), FTP - File Transfer Protocol (FTP), SFTP - SSH File Transfer Protocol (SFTP), iWARP - Internet Wide Area RDMA Protocol (iWARP), RoCE - RDMA over Converged Ethernet Protocol, RoCEv2 - RDMA over Converged Ethernet Protocol Version 2, I2C - Inter-Integrated Circuit Bus, TCP - Transmission Control Protocol (TCP), UDP - User Datagram Protocol (UDP), TFTP - Trivial File Transfer Protocol (TFTP), NVLink - NVLink, OEM - OEM-specific, DisplayPort - DisplayPort, HDMI - HDMI, VGA - VGA, DVI - DVI. |
BIOS Updates for iLO 6
The BIOS schema updated from Bios.v1_0_0.Bios
to Bios.v1_0_5.Bios
NOTE: Supported Bios attributes will vary across different platforms.
Attributes Added
AccessControlService (Access Control Service)
AllowLoginWithIlo (Allow login with %s accounts)
Amd5LevelPage (AMD 5-Level Page)
AmdCdma (AMD Cacheable Direct Memory Access)
AmdCstC2Latency (ACPI CST C2 Latency)
AmdDmaRemapping (AMD DMA Remapping)
AMDPerformanceWorkloadProfile (AMD Performance Workload Profile)
AmdL1Prefetcher (L1 Stream HW Prefetcher)
AmdL2Prefetcher (L2 Stream HW Prefetcher)
AmdMemPStates (Memory PStates)
AmdMemoryBurstRefresh (DRAM Burst Refresh Mode)
AmdPeriodicDirectoryRinse (AMD Periodic Directory Rinse)
AmdSecureMemoryEncryption (AMD Secure Memory Encryption)
AmdSecureNestedPaging (AMD Secure Nested Paging)
AmdXGMILinkSpeed (AMD xGMI Link Speed)
ApplicationPowerBoost (Infinity Fabric Power Management)
DramControllerPowerDown (DRAM Controller Power Down)
EmbSata3Aspm (SATA Power Management(SALP))
EmbSata3PCIeOptionROM (PCIe Option ROM)
EmbSata4Aspm (SATA Power Management(SALP))
EmbSata4Enable (SATA Device Disable)
EmbSata4PCIeOptionROM (PCIe Option ROM)
EmbeddedIpxe (Embedded iPXE)
EmsConsole (EMS Console)
EnabledCoresPerProc (Enabled Cores per Processor)
HourFormat (Hour Format)
InfinityFabricPstate (Infinity Fabric Performance State)
IpmiWatchdogTimerAction (IPMI Watchdog Timer Action)
IpmiWatchdogTimerStatus (IPMI Watchdog Timer)
IpmiWatchdogTimerTimeout (IPMI Watchdog Timer Timeout)
IpxeAutoStartScriptLocation (iPXE Auto-Start Script Location)
IpxeBootOrder (Add Embedded iPXE to Boot Order)
IpxeScriptAutoStart (iPXE Script Auto-Start)
IpxeScriptVerification (iPXE Script Verification)
IpxeStartupUrl (Network Location for iPXE Auto-Start Script)
LastLevelCacheAsNUMANode (Last-Level Cache (LLC) As NUMA Node)
MicrosoftSecuredCoreSupport (Microsoft(R) Secured-core Support)
MinimumSevAsid (Minimum SEV ASID)
Ocp2AuxiliaryPower (OCP Slot 2 Auxiliary Power)
OmitBootDeviceEvent (Omit Boot Device Event)
PackagePowerLimitControlMode (Package Power Limit Control Mode)
PackagePowerLimitValue (Package Power Limit value)
PatrolScrubDuration (Patrol Scrub Duration)
PlatformRASPolicy (Platform RAS Policy)
PciSlot9Aspm (PCIe Power Management(ASPM))
PciSlot10Aspm (PCIe Power Management(ASPM))
PciSlot10Bifurcation (PCIe Slot 10 Bifurcation)
PciSlot10Enable (PCIe Device Disable)
PciSlot10LinkSpeed (PCIe Link Speed)
PciSlot9Bifurcation (PCIe Slot 9 Bifurcation)
PciSlot9Enable (PCIe Device Disable)
PciSlot9LinkSpeed (PCIe Link Speed)
PciSlot9OptionROM (PCIe Option ROM)
PciSlot10OptionROM (PCIe Option ROM)
PciSlot11Aspm (PCIe Power Management(ASPM))
PciSlot11Bifurcation (PCIe Slot 11 Bifurcation)
PciSlot11Enable (PCIe Device Disable)
PciSlot11LinkSpeed (PCIe Link Speed)
PciSlot11OptionROM (PCIe Option ROM)
PciSlot12Aspm (PCIe Power Management(ASPM))
PciSlot12Bifurcation (PCIe Slot 12 Bifurcation)
PciSlot12Enable (PCIe Device Disable)
PostAsr (POST ASR)
PostAsrDelay (POST ASR Timer)
PostScreenMode (POST Screen Mode)
ProcAMDBoost (AMD Core Performance Boost)
ProcAMDBoostControl (AMD Fmax Boost Limit Control)
ProcAmdFmax (AMD Fmax Boost Limit)
ProcAmdIoVt (AMD I/O Virtualization Technology)
ProcSMT (AMD SMT Option)
Pstate0Frequency (Pstate0 Frequency (MHz))
RedundantPowerSupplyGpuDomain (Redundant Power Supply Mode - GPU Domain)
RedundantPowerSupplySystemDomain (Redundant Power Supply Mode - System Domain)
SataSanitize (SATA Sanitize)
SciRasSupport (SCI RAS Support)
Slot<SlotNumber(1-23)> MctpBroadcastSupport (PCIe Slot {SlotNumber(1-23)} MCTP Broadcast Support)
:Slot{SlotNumber(1-23)}NicBoot{BootNumber(1-8)}
SpeculativeLockScheduling (Page Table Entry Speculative Lock Scheduling)
TPM2StorageDisable (TPM 2.0 Storage Hierarchy)
TransparentSecureMemoryEncryption (Transparent Secure Memory Encryption)
UefiShellPhysicalPresenceKeystroke (Physical Presence with Keystroke)
Attributes Deprecated
AdjSecPrefetch (Adjacent Sector Prefetch)
AsrStatus (ASR Status)
AsrTimeoutMinutes (ASR Timeout)
BootMode (Boot Mode)
ChannelInterleaving (Channel Interleaving)
CoreBoosting (Core Boosting)
DcuIpPrefetcher (DCU IP Prefetcher)
DirectToUpi (Direct To UPI (D2K))
EmbNicAspm (PCIe Power Management(ASPM))
EmbNicEnable (PCIe Device Disable)
EmbNicLinkSpeed (PCIe Link Speed)
EmbNicPCIeOptionROM (PCIe Option ROM)
EmbSas1Aspm (PCIe Power Management(ASPM))
EmbSas1Boot (Embedded SAS Controller 1)
EmbSas1Enable (PCIe Device Disable
EmbSas1LinkSpeed (PCIe Link Speed)
EmbSas1PcieOptionROM (PCIe Option ROM)
EmbeddedSata (Embedded SATA Configuration)
EmbSata4PCIeOptionROM (PCIe Option ROM)
EnergyEfficientTurbo (Energy Efficient Turbo)
EnergyPerfBias (Energy/Performance Bias)
EnhancedProcPerf (Enhanced Processor Performance
FlexLom1Aspm (PCIe Power Management(ASPM))
FlexLom1Enable (PCIe Device Disable)
FlexLom1LinkSpeed (PCIe Link Speed)
FlexLom1PCIeOptionROM (PCIe Option ROM)
HwPrefetcher (HW Prefetcher)
IntelDmiLinkFreq (Intel DMI Link Frequency)
IntelNicDmaChannels (Intel NIC DMA Channels (IOAT))
IntelPerfMonitoring (Intel Performance Monitoring Support)
IntelProcVtd (Intel(R) VT-d)
IntelSpeedSelect (Intel(R) Speed Select)
IntelTxt (Intel(R) TXT Support)
IntelUpiFreq (Intel UPI Link Frequency)
IntelUpiLinkEn (Intel UPI Link Enablement)
IntelUpiPowerManagement (Intel UPI Link Power Management)
InternalSDCardSlot (Internal SD Card Slot)
LlcPrefetch (LLC Prefetch)
LocalRemoteThreshold (Local/Remote Threshold)
MemFastTraining (Memory Fast Training)
MemMirrorMode (Memory Mirroring Mode)
MemoryControllerInterleaving (Memory Controller Interleaving)
MemoryRemap (Memory Remap)
MinProcIdlePkgState (Minimum Processor Idle Power Package C-State)
NodeInterleaving (Node Interleaving)
NvDimmNMemFunctionality (NVDIMM-N Support)
NvDimmNMemInterleaving (NVDIMM-N Interleaving)
NvDimmNSanitizePolicy (NVDIMM-N Sanitize/Erase on Next Reboot Policy)
NvdimmLabelSupport (NVDIMM-N OS Label Support)
NvmeFormat<Number (1-50) (NVMe Drive <Number(1-50)>)
OpportunisticSelfRefresh (Opportunistic Self-Refresh)
PciPeerToPeerSerialization (PCI Peer to Peer Serialization)
PciResourcePadding (NVMe PCIe Resource Padding)
PersistentMemBackupPowerPolicy (Persistent Memory Backup Power Policy)
PersistentMemScanMem (Persistent Memory Integrity Check)
StaleAtoS (Stale A to S)
SubNumaClustering (Sub-NUMA Clustering)
Tpm20SoftwareInterfaceOperation (TPM 2.0 Software Interface Operation)
TpmFips (Current TPM FIPS mode)
TpmFipsModeSwitch (TPM FIPS Mode Switch)
TpmModeSwitchOperation (TPM Mode Switch Operation)
TpmOperation (TPM 1.2 Operation)
TpmType (Current TPM Type)
UefiOptimizedBoot (UEFI Optimized Boot)
UncoreFreqScaling (Uncore Frequency Scaling)
UpiPrefetcher (UPI Prefetcher)
Getting Started
Tips for Using the RESTful API
The RESTful API for HPE iLO is available on HPE ProLiant Gen11 servers running iLO 6 with the iLO Standard license, although some features in the data might not be available without an Advanced license.
To access the RESTful API, you need an HTTPS-capable client, such as a web browser with the Postman REST Client plugin extension or cURL (a popular command line HTTP utility).
RESTful Interface Tool and Python Examples
Although not a requirement, you can use the RESTful Interface Tool with the RESTful API. This command line tool provides a level of abstraction and convenience above direct access to the RESTful API. For details see: http://www.hpe.com/info/restfulapi.
**Python: See ex1_functionname() in the Python example code. This means look for the specified function name in the python example code.
Also, Hewlett Packard Enterprise published example Python code that implements a number of common operations in a RESTful API client. This code can be downloaded at https://github.com/HewlettPackard/python-ilorest-library. In some cases the examples in this document may refer to examples in the Python code with this notation:
If you prefer not to implement a client in Python, this serves as a good pseudocode implementing the logic required to perform an operation.
Example REST API operation with cURL
> curl https://{iLO}/redfish/v1/ -i --insecure -L
- -i returns HTTP response headers
- –insecure bypasses TLS/SSL certification verification
- -L follows HTTP redirect
The above command returns JSON like this:
{
"@odata.context": "/redfish/v1/$metadata#ServiceRoot",
"@odata.etag": "W/\"B869D8CC\"",
"@odata.id": "/redfish/v1/",
"@odata.type": "#ServiceRoot.v1_1_0.ServiceRoot",
"AccountService": {
"@odata.id": "/redfish/v1/AccountService/"
},
"Chassis": {
"@odata.id": "/redfish/v1/Chassis/"
},
"EventService": {
"@odata.id": "/redfish/v1/EventService/"
},
"Id": "v1",
"JsonSchemas": {
"@odata.id": "/redfish/v1/Schemas/"
},
"Links": {
"Sessions": {
"@odata.id": "/redfish/v1/SessionService/Sessions/"
}
},
"Managers": {
"@odata.id": "/redfish/v1/Managers/"
},
"Name": "HPE RESTful Root Service",
"Oem": {
"Hpe": {
"@odata.type": "#HpeiLOServiceExt.v2_0_0.HpeiLOServiceExt",
"Links": {
"ResourceDirectory": {
"@odata.id": "/redfish/v1/ResourceDirectory/"
}
},
"Manager": [
{
"DefaultLanguage": "en",
"FQDN": "edited",
"HostName": "ILO",
"Languages": [
{
"Language": "en",
"TranslationName": "English",
"Version": "1.10"
}
],
"ManagerFirmwareVersion": "1.10",
"ManagerType": "iLO 6"
}
],
"Moniker": {
"ADVLIC": "iLO Advanced",
"BMC": "iLO",
"BSYS": "BladeSystem",
"CLASS": "Baseboard Management Controller",
"IPROV": "Intelligent Provisioning",
"PRODABR": "iLO",
"PRODFAM": "Integrated Lights-Out",
"PRODGEN": "iLO 6",
"PRODNAM": "Integrated Lights-Out 6",
"PRODTAG": "HPE iLO 6",
"STDLIC": "iLO Standard",
"SUMGR": "Smart Update Manager",
"SYSFAM": "ProLiant",
"VENDABR": "HPE",
"VENDNAM": "Hewlett Packard Enterprise",
"WWW": "www.hpe.com",
"WWWAHSV": "www.hpe.com/servers/ahsv",
"WWWBMC": "www.hpe.com/info/ilo",
"WWWDOC": "www.hpe.com/support/ilo-docs",
"WWWERS": "www.hpe.com/services/getconnected",
"WWWGLIS": "reserved for liconf URI",
"WWWIOL": "www.hpe.com/info/insightonline",
"WWWLIC": "www.hpe.com/info/ilo/licensing",
"WWWPASS": "www.hpe.com/support/hpesc",
"WWWPRV": "www.hpe.com/info/privacy",
"WWWSUP": "www.hpe.com/support/ilo6",
"WWWSWLIC": "www.hpe.com/software/SWLicensing"
},
"Sessions": {
"CertCommonName": "edited",
"CertificateLoginEnabled": false,
"KerberosEnabled": false,
"LDAPAuthLicenced": true,
"LDAPEnabled": false,
"LocalLoginEnabled": true,
"LoginFailureDelay": 0,
"LoginHint": {
"Hint": "POST to /Sessions to login using the following JSON object:",
"HintPOSTData": {
"Password": "password",
"UserName": "username"
}
},
"SecurityOverride": false,
"ServerName": "edited"
},
"Time": "2017-04-03T05:05:01Z"
}
},
"RedfishVersion": "1.0.0",
"Registries": {
"@odata.id": "/redfish/v1/Registries/"
},
"SessionService": {
"@odata.id": "/redfish/v1/SessionService/"
},
"Systems": {
"@odata.id": "/redfish/v1/Systems/"
},
"UUID": "edited",
"UpdateService": {
"@odata.id": "/redfish/v1/UpdateService/"
}
}
Let’s perform our first GET operation using the RESTful API. We will do an HTTP GET on the iLO HTTPS port, typically port 443 (although it could be different if you have previously configured iLO to use another port). Your client should be prepared to handle the HTTPS certificate challenge. The interface is not available over open HTTP (port 80), so you must use HTTPS.
Our GET operation will be against a resource at /redfish/v1/
(with a trailing slash):
It is best to perform this initial GET with a tool like the CURL or the Postman REST Client mentioned above. Later you will want to do this with your own scripting code, but for now it’s useful to see the HTTP header information exchanged using a browser.
CURL is a command line utility available for many Operating Systems that enables easy access to the RESTful API. CURL is available at https://curl.se. Note that all the CURL examples will use a flag –insecure. This causes CURL to bypass validation of the HTTPS certificate. In real use iLO should be configured to use a user-supplied certificate and this option is not necessary. Notice also that we use the –L option to force CURL to follow HTTP redirect responses. If iLO changes URI locations for various items, it can indicate to the client where the new location is and automatically follow the new link.
In JSON, there is no strong ordering of property names, so iLO may return JSON properties in any order. Likewise, iLO cannot assume the order of properties in any submitted JSON. This is why the best scripting data structure for a RESTful client is a dictionary: a simple set of unordered key/value pairs. This lack of ordering is also the reason you see embedded structure within objects (objects within objects). This allows us to keep related data together that is more logically organized, aesthetically pleasing to view, and helps avoid property name conflicts or ridiculously long property names. It also allows us to use identical blocks of JSON in many places in the data model, like status.
HTTP Resource Operations
Operation | HTTP Command | Description |
---|---|---|
Create | POST resource URI (payload = resource data) | Creates a new resource or invokes a custom action. A synchronous POST returns the newly created resource. |
Read | GET resource URI | Returns the requested resource representation. |
Update | PATCH or PUT resource URI (payload = update data) | Updates an existing resource. You can only PATCH properties that are marked readonly = false in the schema. |
Delete | DELETE resource URI | Deletes the specified resource. |
HTTP Status Return Codes
Return Status | Description |
---|---|
2xx | Successful operation. |
308 | The resource has moved |
4xx | Client-side error with message returned |
5xx | iLO error with error message returned |
Navigating the Data Model
The Redfish API is designed to be implemented on many different models of servers and other IT infrastructure devices for years to come. These devices may be quite different from one another. For this reason, the Redfish API does not specify the URIs to various resources. For example, a client cannot assume the BIOS version information is always at a particular URI.
This is more complex for the client, but is necessary to make sure the data model can change to accommodate various future server architectures without requiring specification changes. As an example, if the BIOS version is at /redfish/v1/Systems/1
, and a client assumed it is always there, the client would then break when the interface is implemented on a different type of architecture with many compute nodes, each with its own BIOS version, or on other vendor implementations.
Redfish 1.6 (iLO 6 v1.05) URI Templates
As of Redfish 1.6, a number of resource types have URI template specifications to be compatible with OpenAPI 3.0. Please see the Redfish 1.6 CSDL schema for details on URI templates for specific types.
A client must still perform GET operations on a Redfish API service in order to discover what resources are available. For instance, just because a Chassis has a template of /redfish/v1/Chassis/{ChassisId}
means that a client must still GET /redfish/v1/Chassis
in order to find the valid values of {ChassisId}
.
Iterating Collections
curl https://{iLO}/redfish/v1/systems/ -i --insecure -u username:password -L
import sys
import redfish
# When running remotely connect using the iLO address, iLO account name,
# and password to send https requests
iLO_host = "https://{iLO}"
login_account = "admin"
login_password = "password"
## Create a REDFISH object
REDFISH_OBJ = redfish.RedfishClient(base_url=iLO_host,username=login_account, \
password=login_password, default_prefix='/redfish/v1')
# Login into the server and create a session
REDFISH_OBJ.login(auth="session")
# Do a GET on a given path
response = REDFISH_OBJ.get("/redfish/v1/systems/", None)
# Print out the response
sys.stdout.write("%s\n" % response)
# Logout of the current session
REDFISH_OBJ.logout()
JSON response example:
{
"@odata.id": "/redfish/v1/systems/",
"@odata.context": "/redfish/v1/$metadata/",
"@odata.type": "#ComputerSystemCollection.ComputerSystemCollection",
"Members@odata.count": 1,
"Members": [
{
"@odata.id": "/redfish/v1/systems/1/"
}
]
}
Many operations will require you to locate the resource you wish to use. Most of these resources are members of “collections” (arrays of similar items). The method to find collections members is consistent for compute nodes, chassis, management processors, and many other resources in the data model.
Find a Compute Node
curl https://{host}/redfish/v1/systems/{item}/ -i --insecure -u username:password -L
import sys
import redfish
# When running remotely connect using the iLO address, iLO account name,
# and password to send https requests
iLO_host = "https://{iLO}"
login_account = "admin"
login_password = "password"
## Create a REDFISH object
REDFISH_OBJ = redfish.RedfishClient(base_url=iLO_host,username=login_account, \
password=login_password, default_prefix='/redfish/v1')
# Login into the server and create a session
REDFISH_OBJ.login(auth="session")
# Do a GET on a given path
response = REDFISH_OBJ.get("/redfish/v1/systems/{item}/", None)
# Print out the response
sys.stdout.write("%s\n" % response)
# Logout of the current session
REDFISH_OBJ.logout()
JSON response example:
{
"@odata.context": "/redfish/v1/$metadata#Systems/Members/$entity",
"@odata.id": "/redfish/v1/Systems/1/",
"@odata.type": "#ComputerSystem.1.0.1.ComputerSystem",
...
...
"SerialNumber": "Kappa",
"Status": {
"Health": "Warning",
"State": "Enabled"
},
"SystemType": "Physical",
"UUID": "00000000-0000-614B-7070-610000000000"
}
A Compute node represents a logical computer system with attributes such as processors, memory, BIOS, power state, firmware version, etc. To find a compute node GET /redfish/v1/systems
and iterate the “Members” array in the returned JSON. Each member has a link to a compute node.
Find a compute node by iterating the systems collection at /redfish/v1/systems/
.
You can then GET the compute node, PATCH values, or perform Actions.
Find a Chassis
curl https://{host}/redfish/v1/chassis/{item}/ -i --insecure -u username:password -L
import sys
import redfish
# When running remotely connect using the iLO address, iLO account name,
# and password to send https requests
iLO_host = "https://{iLO}"
login_account = "admin"
login_password = "password"
## Create a REDFISH object
REDFISH_OBJ = redfish.RedfishClient(base_url=iLO_host,username=login_account, \
password=login_password, default_prefix='/redfish/v1')
# Login into the server and create a session
REDFISH_OBJ.login(auth="session")
# Do a GET on a given path
response = REDFISH_OBJ.get("/redfish/v1/chassis/{item}/", None)
# Print out the response
sys.stdout.write("%s\n" % response)
# Logout of the current session
REDFISH_OBJ.logout()
JSON response example:
{
"@odata.context": "/redfish/v1/$metadata#Chassis/Members/$entity",
"@odata.id": "/redfish/v1/Chassis/1/",
"@odata.type": "#Chassis.1.0.0.Chassis",
"ChassisType": "RackMount",
...
...
"Status": {
"Health": "Warning",
"State": "Enabled"
},
"Thermal": {
"@odata.id": "/redfish/v1/Chassis/1/Thermal/"
}
}
A Chassis represents a physical or virtual container of compute resources with attributes such as FRU information, power supplies, temperature, etc. To find a chassis GET /redfish/v1/chassis
and iterate the “Members” array in the returned JSON. Each member has a link to a chassis.
Find a chassis by iterating the chassis collection at /redfish/v1/chassis/
.
You can then GET the chassis, PATCH values, or perform Actions.
Find the iLO 6 Management Processor
curl https://{host}/redfish/v1/managers/{item}/ -i --insecure -u username:password -L
import sys
import redfish
# When running remotely connect using the iLO address, iLO account name,
# and password to send https requests
iLO_host = "https://{iLO}"
login_account = "admin"
login_password = "password"
## Create a REDFISH object
REDFISH_OBJ = redfish.RedfishClient(base_url=iLO_host,username=login_account, \
password=login_password, default_prefix='/redfish/v1')
# Login into the server and create a session
REDFISH_OBJ.login(auth="session")
# Do a GET on a given path
response = REDFISH_OBJ.get("/redfish/v1/managers/{item}/", None)
# Print out the response
sys.stdout.write("%s\n" % response)
# Logout of the current session
REDFISH_OBJ.logout()
JSON response example:
{
"@odata.context": "/redfish/v1/$metadata#Managers/Members/$entity",
"@odata.id": "/redfish/v1/Managers/1/",
"@odata.type": "#Manager.1.0.0.Manager",
...
...
"Status": {
"State": "Enabled"
},
"UUID": null,
"VirtualMedia": {
"@odata.id": "/redfish/v1/Managers/1/VirtualMedia/"
}
}
A Manager represents a management processor (or “BMC”) that manages chassis and compute resources. For HPE ProLiant Gen11 Servers, the manager is iLO 6. Managers contain attributes such as networking state and configuration, management services, security configuration, etc. To find a manager GET /redfish/v1/managers
and iterate the “Members” array in the returned JSON. Each member has a link to a chassis.
Find a manager by iterating the manager collection at /redfish/v1/managers/
.
You can then GET the manager, PATCH values, or perform Actions.
OData query options
Redfish is an OData-derived protocol with resources linking to other resources using @odata.id
:
{"@odata.id": "/redfish/v1/link_to_some_other_resource"}
The iLO 6 Redfish implementation offers several OData services aiming at facilitating the consumption of data by Redfish clients.
As an example, the OData $expand
query option causes the OData service to automatically replace a link with the results of an internal GET of the indicated URI. This is essential to allow the API to scale for clients. An example use case is to expand an event log to return the log entries inline with the collection and reduce the number of GETs required by the client.
Examples of client requests to expand (in the general OData case) looks like:
GET /redfish/v1/some_resource?$expand=*($levels=1)
- Expand any references 1 level. Levels is assumed to be 1 by default so this is the same asGET /redfish/v1/some_resource?$expand=*
GET /redfish/v1/some_resource?$expand=*($levels=3)
- Expand any references 3 levels deep. This case could require loop detection (For example, system expanding a link to chassis expanding a link back to system).GET /redfish/v1/some_resource?$expand=.
- Expand any references EXCEPT those found under the Links section.GET /redfish/v1/some_resource?$expand=./Oem/Hpe
- Expand any references found in the Oem/Hpe section of the resource.
OData query options supported by iLO 6 are presented below along with use case examples.
iLO 6 $expand
Using the rules above, iLO 6 supports $expand
in this way:
$expand
is applicable to HTTP GET only.
$expand=.
, $expand=*
, and $expand=($levels=n)
result in the same behavior:
- Expands all links in both root and Oem/Hpe sections not inside the
Links
sections. - Levels is always interpreted as 1, regardless of n. This is to avoid the potential for expanding recursively for interlinked resources.
- The
Links
section is never expanded. This is to avoid expanding the Chassis and Manager related links on GET operations to System.
NOTE:
The root resource at /redfish/v1/
is available without authentication and has navigational links that can be expanded. An $expand
request does not result in expansion unless valid authentication credentials are supplied.
iLO 6 $expand
examples
The first example in the right pane retrieves the ChassisCollection
without the $expand
query option:
GET /redfish/v1/Chassis/
{
"@odata.context": "/redfish/v1/$metadata#ChassisCollection.ChassisCollection",
"@odata.etag": "W/\"AA6D42B0\"",
"@odata.id": "/redfish/v1/Chassis",
"@odata.type": "#ChassisCollection.ChassisCollection",
"Description": "Computer System Chassis View",
"Name": "Computer System Chassis",
"Members": [
{
"@odata.id": "/redfish/v1/Chassis/1"
}
],
"Members@odata.count": 1
}
The next example retrieves the same ChassisCollection
with the $expand=.
query option:
GET /redfish/v1/Chassis/?$expand=.
{
"@odata.context": "/redfish/v1/$metadata#ChassisCollection.ChassisCollection",
"@odata.etag": "W/\"5DDB6CFA\"",
"@odata.id": "/redfish/v1/Chassis/",
"@odata.type": "#ChassisCollection.ChassisCollection",
"Description": "Computer System Chassis View",
"Name": "Computer System Chassis",
"Members": [
{
"@odata.context": "/redfish/v1/$metadata#Chassis.Chassis",
"@odata.id": "/redfish/v1/Chassis/1/",
"@odata.type": "#Chassis.v1_19_0.Chassis",
"Id": "1",
"AssetTag": "",
"ChassisType": "RackMount",
"EnvironmentalClass": "A2",
"Links": {
"ManagedBy": [
{
"@odata.id": "/redfish/v1/Managers/1/"
}
],
"ComputerSystems": [
{
"@odata.id": "/redfish/v1/Systems/1/"
}
],
"Drives": [
{
"@odata.id": "/redfish/v1/Systems/1/Storage/DA000006/Drives/DA000006/"
},
............
],
"Members@odata.count": 1
}
iLO 6 only
query option
iLO 6 supports the only
query parameter documented in the Redfish API specification. This query parameter is ignored except on collections with only one member. Examples include the ComputerSystemCollection
, ChassisCollection
, and ManagerCollection
.
iLO 6 only
example
The example in the right pane retrieves the chassis collection without the only
query option.
GET /redfish/v1/Chassis/
{
"@odata.context": "/redfish/v1/$metadata#ChassisCollection.ChassisCollection",
"@odata.etag": "W/\"AA6D42B0\"",
"@odata.id": "/redfish/v1/Chassis/",
"@odata.type": "#ChassisCollection.ChassisCollection",
"Description": "Computer System Chassis View",
"Name": "Computer System Chassis",
"Members": [
{
"@odata.id": "/redfish/v1/Chassis/1/"
}
],
"Members@odata.count": 1
}
The following example in the right pane retrieves the a chassis collection of a system with only one chassis, using the only
query option.
GET /redfish/v1/Chassis/?only
{
"@odata.context": "/redfish/v1/$metadata#Chassis.Chassis",
"@odata.etag": "W/\"E623AF83\"",
"@odata.id": "/redfish/v1/Chassis/1/",
"@odata.type": "#Chassis.v1_19_0.Chassis",
"Id": "1",
"AssetTag": "",
"ChassisType": "RackMount",
"EnvironmentalClass": "A2",
"Links": {
"ManagedBy": [
{
"@odata.id": "/redfish/v1/Managers/1/"
}
],
.....
"PCIeDevices": {
"@odata.id": "/redfish/v1/Chassis/1/PCIeDevices/"
},
"PCIeSlots": {
"@odata.id": "/redfish/v1/Chassis/1/PCIeSlots/"
},
"Power": {
"@odata.id": "/redfish/v1/Chassis/1/Power/"
},
"PowerState": "On",
"SKU": "P54199-B21",
"SerialNumber": "TWA22525A1",
"Status": {
"Health": "OK",
"State": "Enabled"
},
"Thermal": {
"@odata.id": "/redfish/v1/Chassis/1/Thermal/"
}
}
The next example in the right pane uses the only
query option to retrieve the chassis collection of a system containing a Pensando Data Processor Unit (DPU).
GET /redfish/v1/Chassis/?only
{
"@odata.context": "/redfish/v1/$metadata#ChassisCollection.ChassisCollection",
"@odata.etag": "W/\"570254F2\"",
"@odata.id": "/redfish/v1/Chassis",
"@odata.type": "#ChassisCollection.ChassisCollection",
"Description": "Computer System Chassis View",
"Name": "Computer System Chassis",
"Members": [
{
"@odata.id": "/redfish/v1/Chassis/1"
},
{
"@odata.id": "/redfish/v1/Chassis/2"
}
],
"Members@odata.count": 2
}
iLO 6 $filter
query option
The odata.org official site defines the $filter
query as the following:
“The $filter
system query option allows clients to filter a collection of resources that are addressed by a request URL. The expression specified with $filter
is evaluated for each resource in the collection, and only items where the expression evaluates to true are included in the response.”.
Six logical operators (Equals, Not Equals, Greater Than…) can be applied to the $filter
query. They are defined in the OData specifications.
iLO 6 $filter
examples
The following example retrieves the “iLO Dedicated Network Interface” properties (output abbreviated).
GET /redfish/v1/Managers/1/EthernetInterfaces/?$filter=Name eq ‘Manager Dedicated Network Interface’
{
"@odata.context": "/redfish/v1/$metadata#EthernetInterfaceCollection.EthernetInterfaceCollection",
"@odata.etag": "W/\"3E2CCBB8\"",
"@odata.id": "/redfish/v1/Managers/1/EthernetInterfaces/",
"@odata.type": "#EthernetInterfaceCollection.EthernetInterfaceCollection",
"Description": "Configuration of Manager Network Interfaces",
"Name": "Manager Network Interfaces",
"Members": [
{
"@odata.context": "/redfish/v1/$metadata#EthernetInterface.EthernetInterface",
"@odata.id": "/redfish/v1/Managers/1/EthernetInterfaces/1/",
"@odata.type": "#EthernetInterface.v1_4_1.EthernetInterface",
"Id": "1",
"AutoNeg": true,
"Name": "Manager Dedicated Network Interface",
"NameServers": [],
"DHCPv4": {
"DHCPEnabled": false,
"UseDNSServers": false,
"UseDomainName": false,
"UseGateway": false,
"UseNTPServers": false,
"UseStaticRoutes": false
},
"DHCPv6": {
"OperatingMode": "Stateful",
"UseDNSServers": false,
"UseDomainName": false,
"UseNTPServers": false,
"UseRapidCommit": false
},
"Description": "Configuration of this Manager Network Interface",
"FQDN": null,
"FullDuplex": true,
"HostName": "ILOTWA22525A1",
.......
"Status": {
"Health": "OK",
"State": "Enabled"
},
"VLAN": {
"VLANEnable": false,
"VLANId": null
}
}
],
"Members@odata.count": 1
}
The next example retrieves only Integrated Management Log (IML) entries with severity Repaired
.
GET /redfish/v1/Systems/1/LogServices/IML/Entries/?$filter=Oem.Hpe.Severity eq ‘Repaired’
{
"@odata.context": "/redfish/v1/$metadata#LogEntryCollection.LogEntryCollection",
"@odata.etag": "W/\"CA3EE996\"",
"@odata.id": "/redfish/v1/Systems/1/LogServices/IML/Entries",
"@odata.type": "#LogEntryCollection.LogEntryCollection",
"Description": "Integrated Management Logs view",
"Name": "Integrated Management Logs view",
"Members": [
{
"@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
"@odata.id": "/redfish/v1/Systems/1/LogServices/IML/Entries/39",
"@odata.type": "#LogEntry.v1_11_0.LogEntry",
"Id": "39",
"Created": "2022-09-25T04:39:05Z",
"EntryType": "Oem",
"Message": "System Overheating (Temperature Sensor 1, Location Ambient, Temperature 43)",
"Name": "Integrated Management Log",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeLogEntry.HpeLogEntry",
"@odata.type": "#HpeLogEntry.v2_4_0.HpeLogEntry",
"Categories": [
"Cooling"
],
"Class": 2,
"ClassDescription": "Environment",
"Code": 19,
"Count": 1,
"EventNumber": 56,
"LearnMoreLink": "http://www.hpe.com/support/class0x0002code0x0013-gen11",
"RecommendedAction": "Check fans, processor heat sink and air baffles installation.",
"Repaired": true,
"Severity": "Repaired",
"Updated": "2022-09-25T04:39:10Z"
}
},
"OemRecordFormat": "Hpe-IML",
"Severity": "OK"
},
.....
{
"@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
"@odata.id": "/redfish/v1/Systems/1/LogServices/IML/Entries/92",
"@odata.type": "#LogEntry.v1_11_0.LogEntry",
"Id": "92",
"Created": "2022-09-25T06:19:17Z",
"EntryType": "Oem",
"Message": "Automatic Operating System Shutdown Initiated Due to Overheat Condition",
"Name": "Integrated Management Log",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeLogEntry.HpeLogEntry",
"@odata.type": "#HpeLogEntry.v2_4_0.HpeLogEntry",
"Categories": [
"Other"
],
"Class": 14,
"ClassDescription": "OS",
"Code": 2,
"Count": 1,
"EventNumber": 109,
"LearnMoreLink": "http://www.hpe.com/support/class0x000ecode0x0002-gen11",
"RecommendedAction": "Check simultaneously logged messages for cause of shutdown and address those issues accordingly.",
"Repaired": true,
"Severity": "Repaired",
"Updated": "2022-09-25T06:19:22Z"
}
},
"OemRecordFormat": "Hpe-IML",
"Severity": "OK"
}
],
"Members@odata.count": 16
}
The following example retrieves IML entries created after a specific date.
GET /redfish/v1/Systems/1/LogServices/IML/Entries/?$filter=Created gt ‘2022-10-04T06:19:22Z’
{
"@odata.context": "/redfish/v1/$metadata#LogEntryCollection.LogEntryCollection",
"@odata.etag": "W/\"EC19D60B\"",
"@odata.id": "/redfish/v1/Systems/1/LogServices/IML/Entries",
"@odata.type": "#LogEntryCollection.LogEntryCollection",
"Description": "Integrated Management Logs view",
"Name": "Integrated Management Logs view",
"Members": [
{
"@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
"@odata.id": "/redfish/v1/Systems/1/LogServices/IML/Entries/102",
"@odata.type": "#LogEntry.v1_11_0.LogEntry",
"Id": "102",
"Created": "2022-10-04T16:11:32Z",
"EntryType": "Oem",
"Message": "Maintenance note: Starting F10 GUI",
"Name": "Integrated Management Log",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeLogEntry.HpeLogEntry",
"@odata.type": "#HpeLogEntry.v2_4_0.HpeLogEntry",
"Categories": [
"Maintenance"
],
"Class": 33,
"ClassDescription": "Maintenance",
"Code": 2,
"Count": 1,
"EventNumber": 119,
"Severity": "Informational",
"Updated": "2022-10-04T16:11:32Z"
}
},
"OemRecordFormat": "Hpe-IML",
"Severity": "OK"
},
.......
{
"@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
"@odata.id": "/redfish/v1/Systems/1/LogServices/IML/Entries/105",
"@odata.type": "#LogEntry.v1_11_0.LogEntry",
"Id": "105",
"Created": "2022-10-04T16:25:34Z",
"EntryType": "Oem",
"Message": "Firmware flashed (Broadcom NetXtreme-E BCM5741x adapters 222.1.68.0)",
"Name": "Integrated Management Log",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeLogEntry.HpeLogEntry",
"@odata.type": "#HpeLogEntry.v2_4_0.HpeLogEntry",
"Categories": [
"Administration"
],
"Class": 32,
"ClassDescription": "System Revision",
"Code": 2,
"Count": 1,
"EventNumber": 122,
"Severity": "Informational",
"Updated": "2022-10-04T16:25:34Z"
}
},
"OemRecordFormat": "Hpe-IML",
"Severity": "OK"
}
],
"Members@odata.count": 4
}
iLO 6 $count
query option
The $count
system query option allows Redfish clients to request a count of the matching resources included with the resources in the response.
iLO 6 $count
example
/redfish/v1/systems/1/logservices/SL/Entries/?$count=true
{
"@odata.context": "/redfish/v1/$metadata#LogEntryCollection.LogEntryCollection",
"@odata.etag": "W/\"75983E8D\"",
"@odata.type": "#LogEntryCollection.LogEntryCollection",
"Description": "Security Logs view",
"Name": "Security Logs",
"Members": [],
"Members@odata.count": 31
}
iLO 6 $top
and $skip
query options
The $top
system query option requests the number of items in the queried collection to be included in the result. The $skip
query option requests the number of items in the queried collection that are to be skipped and not included in the result.
iLO 6 $top
and $skip
examples
Retrieve the top (first) ten IML log entries:
GET /redfish/v1/Systems/1/LogServices/IML/Entries/?$top=10
{
"@odata.context": "/redfish/v1/$metadata#LogEntryCollection.LogEntryCollection",
"@odata.etag": "W/\"7E02C697\"",
"@odata.id": "/redfish/v1/Systems/1/LogServices/IML/Entries",
"@odata.type": "#LogEntryCollection.LogEntryCollection",
"Description": "Integrated Management Logs view",
"Name": "Integrated Management Logs view",
"Members": [
{
"@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
"@odata.id": "/redfish/v1/Systems/1/LogServices/IML/Entries/1",
"@odata.type": "#LogEntry.v1_11_0.LogEntry",
"Id": "1",
"Created": "2001-01-01T00:26:39Z",
"EntryType": "Oem",
"Message": "IML Cleared ( user: System Administrator)",
"Name": "Integrated Management Log",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeLogEntry.HpeLogEntry",
"@odata.type": "#HpeLogEntry.v2_4_0.HpeLogEntry",
"Categories": [
"Maintenance",
"Administration"
],
"Class": 33,
"ClassDescription": "Maintenance",
"Code": 1,
"Count": 1,
"EventNumber": 18,
"Severity": "Informational",
"Updated": "2001-01-01T00:26:39Z"
}
},
"OemRecordFormat": "Hpe-IML",
"Severity": "OK"
},
...
{
"@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
"@odata.id": "/redfish/v1/Systems/1/LogServices/IML/Entries/10",
"@odata.type": "#LogEntry.v1_11_0.LogEntry",
"Id": "10",
"Created": "2022-09-15T15:42:14Z",
"EntryType": "Oem",
"Message": "Insufficient Fan Solution",
"Name": "Integrated Management Log",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeLogEntry.HpeLogEntry",
"@odata.type": "#HpeLogEntry.v2_4_0.HpeLogEntry",
"Categories": [
"Cooling"
],
"Class": 2,
"ClassDescription": "Environment",
"Code": 52,
"Count": 2,
"EventNumber": 27,
"LearnMoreLink": "http://www.hpe.com/support/class0x0002code0x0034-gen11",
"RecommendedAction": "Replace any failed or missing fans in the system.",
"Repaired": false,
"Severity": "Critical",
"Updated": "2022-09-15T15:52:10Z"
}
},
"OemRecordFormat": "Hpe-IML",
"Severity": "Critical"
}
],
"Members@odata.count": 10
}
The request below returns IML entries starting at the 22th record (the Members@odata.count
is 31).
GET /redfish/v1/Systems/1/LogServices/IML/Entries/?$skip=21
{
"@odata.context": "/redfish/v1/$metadata#LogEntryCollection.LogEntryCollection",
"@odata.etag": "W/\"2B9C6986\"",
"@odata.id": "/redfish/v1/Systems/1/LogServices/IML/Entries",
"@odata.type": "#LogEntryCollection.LogEntryCollection",
"Description": "Integrated Management Logs view",
"Name": "Integrated Management Logs view",
"Members": [
{
"@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
"@odata.id": "/redfish/v1/Systems/1/LogServices/IML/Entries/19",
"@odata.type": "#LogEntry.v1_11_0.LogEntry",
"Id": "19",
"Created": "2022-05-18T14:55:37Z",
"EntryType": "Oem",
"Message": "HPE Ethernet 1Gb 4-port 331i Adapter - NIC Connectivity status changed to OK for adapter in slot 0, port 1",
"Name": "Integrated Management Log",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeLogEntry.HpeLogEntry",
"@odata.type": "#HpeLogEntry.v2_4_0.HpeLogEntry",
"Categories": [
"Hardware"
],
...
"Severity": "Repaired",
"Updated": "2022-05-18T14:55:37Z"
}
},
"OemRecordFormat": "Hpe-IML",
"Severity": "OK"
},
...
],
"Members@odata.count": 10
}
iLO 6 $select
query option
The $select
query option allows Redfish clients to requests a limited set of properties.
iLO 6 $select
examples
The following example retrieves the RedfishVersion
property of an iLO 6 based server.
GET /redfish/v1/?$select=RedfishVersion
{
"@odata.context": "/redfish/v1/$metadata#ServiceRoot.ServiceRoot",
"@odata.etag": "W/\"217FDE58\"",
"@odata.id": "/redfish/v1",
"@odata.type": "#ServiceRoot.v1_13_0.ServiceRoot",
"RedfishVersion": "1.13.0"
}
The following example returns the ChassisType
, and ServiceLabel
properties of a Data Processor Unit card.
GET /redfish/v1/Chassis/2/?$select=ChassisType,Location/PartLocation/ServiceLabel
{
"@odata.context": "/redfish/v1/$metadata#Chassis.Chassis",
"@odata.etag": "W/\"1B982357\"",
"@odata.id": "/redfish/v1/Chassis/2/",
"@odata.type": "#Chassis.v1_11_2.Chassis",
"ChassisType": "Card",
"Location": {
"PartLocation": {
"ServiceLabel": "PCIe Slot 1"
}
}
}
Authentication and Sessions
The following shows the error displayed on
GET /redfish/v1/systems/
when no authentication is attempted:
401 Forbidden
{
"error": {
"@Message.ExtendedInfo": [
{
"MessageId": "Base.1.0.NoValidSession"
}
],
"code": "iLO.0.10.ExtendedInfo",
"message": "See @Message.ExtendedInfo for more information."
}
}
If you perform an HTTP operation on any other resource other than the root /redfish/v1/
resource, you will receive an HTTP 401 (Forbidden)
error indicating that you don’t have the authentication needed to access the resource.
Basic Authentication
curl https://{iLO}/redfish/v1/systems/ -i --insecure -u username:password -L
import sys
import redfish
# When running remotely connect using the iLO address, iLO account name,
# and password to send https requests
iLO_host = "https://{iLO}"
login_account = "admin"
login_password = "password"
## Create a REDFISH object
REDFISH_OBJ = redfish.RedfishClient(base_url=iLO_host,username=login_account, \
password=login_password, default_prefix='/redfish/v1')
# Login into the server and create a session
REDFISH_OBJ.login(auth="basic")
# Logout of the current session
REDFISH_OBJ.logout()
The RESTful API allows you to use HTTP Basic Authentication using a valid iLO user name and password.
Creating and Using Sessions
curl -H "Content-Type: application/json" -H "OData-Version: 4.0" -X POST --data "@data.json" https://{iLO}/redfish/v1/SessionService/Sessions/ --insecure
import redfish
# When running remotely connect using the iLO address, iLO account name,
# and password to send https requests
iLO_host = "https://{iLO}"
login_account = "admin"
login_password = "password"
## Create a REDFISH object
REDFISH_OBJ = redfish.RedfishClient(base_url=iLO_host,username=login_account, \
password=login_password, default_prefix='/redfish/v1')
# Login into the server and create a session
REDFISH_OBJ.login(auth="session")
Contents of data.json
{
"UserName": "<your username>",
"Password": "<your password>"
}
Successful headers from iLO:
Cache-Control: no-cache
Connection: keep-alive
Content-length: 163
Content-type: application/json; charset=utf-8
Date: Tue, 14 Jun 2016 22:23:39 GMT
ETag: W/"C84E3EA9"
Link: </redfish/v1/SessionService/Sessions/{item}/>; rel=self
Location: https://{iLO}/redfish/v1/SessionService/Sessions/{item}/
OData-Version: 4.0
Server: HPE-iLO-Server/1.30
X-Auth-Token: c3c5f437f94bc24428fe930bbf50904f
X-Frame-Options: sameorigin
X_HP-CHRP-Service-Version: 1.0.3
Successful response from iLO:
{
"error": {
"@Message.ExtendedInfo": [
{
"MessageID": "Base.0.10.Created"
}
],
"code": "iLO.0.10.ExtendedInfo",
"message": "See @Message.ExtendedInfo for more information."
}
}
For more complex multi-resource operations, you should log in and establish a session. To log in, iLO has a session manager object at the documented URI /redfish/v1/sessions/
. To create a session POST a JSON object to the Session manager:
If the session is created successfully, you receive an HTTP 201 (Created) response from iLO. There will also be two important HTTP response headers.
X-Auth-Token Your session token (string). This is a unique string for your login session. It must be included as a header in all subsequent HTTP operations in the session.
Location The URI of the newly created session resource. iLO allocates a new session resource describing your session. This is the URI that you must DELETE against in order to log out. If you lose this location URI, you can find it by crawling the HREF links in the Sessions collection. Store this URI to facilitate logging out.
Using a Session
To use a session, simply include the X-Auth-Token
header supplied by the login response in all REST requests.
Log Out of a Session
curl -X "DELETE" https://{iLO}/redfish/v1/SessionService/Sessions/{item}/ -u admin:password --insecure
import redfish
# When running remotely connect using the iLO address, iLO account name,
# and password to send https requests
iLO_host = "https://{iLO}"
login_account = "admin"
login_password = "password"
## Create a REDFISH object
REDFISH_OBJ = redfish.RedfishClient(base_url=iLO_host,username=login_account, \
password=login_password, default_prefix='/redfish/v1')
# Login into the server and create a session
REDFISH_OBJ.login(auth="session")
# Logout of the current session
REDFISH_OBJ.logout()
iLO supports a limited number of simultaneous sessions. If you do not log out of a session it will expire automatically after a time of inactivity. However, it is good practice to log out when finished with a session.
To log out perform an HTTP DELETE
to the URI that was returned in the “Location” header when you created the session.
Performing Actions
Example of a system resource advertising an available action:
{
"Actions": {
"#ComputerSystem.Reset": {
"ResetType@Redfish.AllowableValues": [
"On",
"ForceOff",
"ForceRestart",
"Nmi",
"PushPowerButton"
],
"target": "/redfish/v1/Systems/1/Actions/ComputerSystem.Reset"
}
}
}
This action may be invoked by performing:
curl --header "Content-Type: application/json" --request POST --data '{"ResetType": "ForceRestart"}' https://{iLO}/redfish/v1/Systems/1/Actions/ComputerSystem.Reset -u username:password --insecure
REST resources usually support HTTP GET to read the current state, and some support modification and removal with HTTP POST, PUT, PATCH, or DELETE.
There are some resources that support other types of operations not easily mapped to HTTP operations. For this reason the Redfish specification defines “Actions”. Actions are HTTP POST operations with a specifically formatted JSON request including the operation to perform and any parameters. For instance, it is not enough to simply tell a server to reset, but it is also necessary to specify the type of reset: cold boot, warm boot, PCI reset, etc. Actions are often used when the operation causes iLO 6 not just to update a value, but to change system state.
In Redfish, the available actions that can be invoked are identified by a “target” property in the resource’s “Actions” object definitions. The parameters identify the supported values with the annotation @Redfish.AllowableValues.
Actions on HPE-specific Extensions
Actions on HPE-specific extensions are invoked in the same way. Find the target
URI for the action and POST a JSON request with parameters.
curl --header "Content-Type: application/json" --request POST --data '{"PushType": "PressAndHold"}' https://{iLO}//redfish/v1/Systems/1/Actions/Oem/Hpe/HpeComputerSystemExt.PowerButton/ -u username:password --insecure
The embedded extensions may also have Actions not specified by the Redfish standard. They are invoked in a similar way. The POST URI may include indicate the HPE specific nature of the action.
The older pre-Redfish form of the Action invocation requires you to specify "Target": "/Oem/Hp"
as one of the properties in the body of the request.
It is recommended that you use the Redfish version of the action invocation.
Managing iLO 6 Users
iLO 6 supports both local user authentication as well as directory authentication.
- Role based local user administration via Redfish
- Directory Authentication configuration via Redfish
All user account modifications require the client to be authenticated with the “Administer User Accounts” privilege (UserConfigPriv
in the Redfish ManagerAccount
)
Local User Administration
iLO 6 has a local user database enabling consistent user management for all interfaces including the Web interface (GUI) as well as the Redfish API. The iLO 6 local user accounts are managed in the AccountService (/redfish/v1/AccountService
). An Accounts
collection in the AccountService enables clients to create, modify, or remove local user accounts.
GET /redfish/v1/AccountService/Accounts/
{
"@odata.context": "/redfish/v1/$metadata#ManagerAccountCollection.ManagerAccountCollection",
"@odata.etag": "W/\"21C260DB\"",
"@odata.id": "/redfish/v1/AccountService/Accounts/",
"@odata.type": "#ManagerAccountCollection.ManagerAccountCollection",
"Description": "iLO User Accounts",
"Name": "Accounts",
"Members": [
{
"@odata.id": "/redfish/v1/AccountService/Accounts/1/"
}
],
"Members@odata.count": 1
}
A local user account consists of a user name, password, and a set of privileges. The RoleId
describes one of three defined Redfish roles based upon assigned privileges. The Oem/Hpe/LoginName
property is a description of the account.
NOTE: Due to a terminology mismatch between the Redfish standard and historical iLO products, the Properties for UserName
and LoginName
are reversed in Redfish vs. the iLO 6 Web interface:
Redfish Property | GUI Term | Description | Example |
---|---|---|---|
UserName | Login Name | The user identity string used with a password to log into iLO 6 | jsmith |
Oem/Hpe/LoginName | User Name | The descriptive name of the user | Jane Smith - Director of IT |
GET /redfish/v1/AccountService/Accounts/1/
{
"@odata.context": "/redfish/v1/$metadata#ManagerAccount.ManagerAccount",
"@odata.etag": "W/\"D9DF9F68\"",
"@odata.id": "/redfish/v1/AccountService/Accounts/1/",
"@odata.type": "#ManagerAccount.v1_1_3.ManagerAccount",
"Id": "1",
"Description": "iLO User Account",
"Links": {
"Role": {
"@odata.id": "/redfish/v1/AccountService/Roles/Administrator/"
}
},
"Name": "User Account",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeiLOAccount.HpeiLOAccount",
"@odata.type": "#HpeiLOAccount.v2_2_0.HpeiLOAccount",
"LoginName": "Jane Smith - Director of IT",
"Privileges": {
"HostBIOSConfigPriv": true,
"HostNICConfigPriv": true,
"HostStorageConfigPriv": true,
"LoginPriv": true,
"RemoteConsolePriv": true,
"SystemRecoveryConfigPriv": true,
"UserConfigPriv": true,
"VirtualMediaPriv": true,
"VirtualPowerAndResetPriv": true,
"iLOConfigPriv": true
},
"ServiceAccount": false
}
},
"Password": null,
"RoleId": "Administrator",
"UserName": "jsmith"
}
Note that
Password
is always shown asnull
even though its PATCHable with a new password
Roles and Privileges
iLO 6 uses a set of privileges assigned to each user account to grant and restrict access to features. iLO 6’s privileges are:
Redfish | iLO Web Interface (GUI) |
---|---|
LoginPriv | Login |
RemoteConsolePriv | Remote Console |
VirtualPowerAndResetPriv | Virtual Power and Reset |
VirtualMediaPriv | Virtual Media |
HostBIOSConfigPriv | Host BIOS |
iLOConfigPriv | Configure iLO Settings |
UserConfigPriv | Administer User Accounts |
HostNICConfigPriv | Host NIC |
HostStorageConfigPriv | Host Storage |
SystemRecoveryConfigPriv | Recovery Set |
Roles
You can use RoleId
to create users with specific starting privileges.
On a GET of the local user account, RoleId
is synthesized based upon the enabled privileges. iLO 6 does not store a separate RoleId
value. For this reason, modifications to raw privileges may or may not result in a changed RoleId
based upon iLO’s mapping.
If the PATCH includes both RoleID
and individual privileges, the privileges corresponding to the RoleId are assigned to the local user account first, and then the explicit privileges are assigned.
PATCH /redfish/v1/AccountService/Accounts/{accountId}
{
"RoleId": "Administrator",
"Oem": {
"Hpe": {
"Privileges": {
"SystemRecoveryConfigPriv": true
}
}
}
}
will set all iLO 6 privileges as long as the account performing the operation already has sufficient privilege to grant these privileges.
Privileges granted on Local Account Creation by RoleId
RoleId | Privileges |
---|---|
Administrator | HostBIOSConfigPriv, HostNICConfigPriv, HostStorageConfigPriv, LoginPriv, RemoteConsolePriv, UserConfigPriv, VirtualMediaPriv, VirtualPowerAndResetPriv, iLOConfigPriv |
Operator | HostBIOSConfigPriv, HostNICConfigPriv, HostStorageConfigPriv, LoginPriv, RemoteConsolePriv, VirtualMediaPriv, VirtualPowerAndResetPriv |
ReadOnly | LoginPriv |
RoleId shown on an existing Local User Account by Privilege
The RoleId
reported is the smallest superset of assigned privileges.
Privileges | RoleId |
---|---|
LoginPriv only | ReadOnly |
iLOConfigPriv or UserConfigPriv or SystemRecoveryConfigPriv and anything else | Administrator |
any other combination | Operator |
Creating a new Local User Account
The simplest possible new local user account create operation is to POST to the Accounts collection, as shown in the example in the right pane.
PATCH /redfish/v1/AccountService/Accounts/{accountId}
{
"UserName": "jsmith",
"Password": "passwordexample"
}
The next example in the right pane creates a user account jsmith
with the default ReadOnly
RoleId and only the iLO 6 Login privilege. Notice that Oem/Hpe/LoginName
defaults to the provided UserName
unless it is specifically specified.
NOTE: Each local user account must have a unique UserName
.
GET /redfish/v1/AccountService/Accounts/{accountId}
{
"@odata.context": "/redfish/v1/$metadata#ManagerAccount.ManagerAccount",
"@odata.etag": "W/\"B103601C\"",
"@odata.id": "/redfish/v1/AccountService/Accounts/12/",
"@odata.type": "#ManagerAccount.v1_1_3.ManagerAccount",
"Id": "12",
"Description": "iLO User Account",
"Links": {
"Role": {
"@odata.id": "/redfish/v1/AccountService/Roles/ReadOnly/"
}
},
"Name": "User Account",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeiLOAccount.HpeiLOAccount",
"@odata.type": "#HpeiLOAccount.v2_2_0.HpeiLOAccount",
"LoginName": "jsmith",
"Privileges": {
"HostBIOSConfigPriv": false,
"HostNICConfigPriv": false,
"HostStorageConfigPriv": false,
"LoginPriv": true,
"RemoteConsolePriv": false,
"SystemRecoveryConfigPriv": false,
"UserConfigPriv": false,
"VirtualMediaPriv": false,
"VirtualPowerAndResetPriv": false,
"iLOConfigPriv": false
},
"ServiceAccount": false
}
},
"Password": null,
"RoleId": "ReadOnly",
"UserName": "jsmith"
}
Creating a new Account using a RoleId
You may specify a RoleId
with a new user account, as shown in the right pane.
POST /redfish/v1/AccountService/Accounts/
{
"UserName": "jsmith",
"Password": "passwordexample",
"RoleId": "Operator"
}
This results in:
GET /redfish/v1/AccountService/Accounts/{accountId}
{
"@odata.context": "/redfish/v1/$metadata#ManagerAccount.ManagerAccount",
"@odata.etag": "W/\"6C16FDE3\"",
"@odata.id": "/redfish/v1/AccountService/Accounts/14/",
"@odata.type": "#ManagerAccount.v1_1_3.ManagerAccount",
"Id": "14",
"Description": "iLO User Account",
"Links": {
"Role": {
"@odata.id": "/redfish/v1/AccountService/Roles/Operator/"
}
},
"Name": "User Account",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeiLOAccount.HpeiLOAccount",
"@odata.type": "#HpeiLOAccount.v2_2_0.HpeiLOAccount",
"LoginName": "jsmith",
"Privileges": {
"HostBIOSConfigPriv": true,
"HostNICConfigPriv": true,
"HostStorageConfigPriv": true,
"LoginPriv": true,
"RemoteConsolePriv": true,
"SystemRecoveryConfigPriv": false,
"UserConfigPriv": false,
"VirtualMediaPriv": true,
"VirtualPowerAndResetPriv": true,
"iLOConfigPriv": false
},
"ServiceAccount": false
}
},
"Password": null,
"RoleId": "Operator",
"UserName": "jsmith"
}
Creating a new Account with specific Privileges
You may also create a local user with specific privileges, as shown in the right pane.
POST /redfish/v1/AccountService/Accounts/
{
"UserName": "jsmith",
"Password": "passwordexample",
"Oem": {
"Hpe": {
"LoginName": "Director of IT",
"Privileges": {
"LoginPriv": true,
"VirtualMediaPriv": true,
"VirtualPowerAndResetPriv": true
}
}
}
}
This results in the following new local user account:
GET /redfish/v1/AccountService/Accounts/{accountId}
{
"@odata.context": "/redfish/v1/$metadata#ManagerAccount.ManagerAccount",
"@odata.etag": "W/\"E8037663\"",
"@odata.id": "/redfish/v1/AccountService/Accounts/15/",
"@odata.type": "#ManagerAccount.v1_1_3.ManagerAccount",
"Id": "15",
"Description": "iLO User Account",
"Links": {
"Role": {
"@odata.id": "/redfish/v1/AccountService/Roles/Operator/"
}
},
"Name": "User Account",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeiLOAccount.HpeiLOAccount",
"@odata.type": "#HpeiLOAccount.v2_2_0.HpeiLOAccount",
"LoginName": "Director of IT",
"Privileges": {
"HostBIOSConfigPriv": false,
"HostNICConfigPriv": false,
"HostStorageConfigPriv": false,
"LoginPriv": true,
"RemoteConsolePriv": false,
"SystemRecoveryConfigPriv": false,
"UserConfigPriv": false,
"VirtualMediaPriv": true,
"VirtualPowerAndResetPriv": true,
"iLOConfigPriv": false
},
"ServiceAccount": false
}
},
"Password": null,
"RoleId": "Operator",
"UserName": "jsmith"
}
Modifying a Local User Account
The following properties are modifiable on an existing local user account:
* UserName
* Password
- this is always returned as null, but you may PATCH it with a value to change the password
* RoleId
- PATCHing RoleId
on an existing local user account will reset it’s existing privileges with those mapped to the RoleId.
* Oem/Hpe/LoginName
* Oem/Hpe/Privileges/*
- any of the privileges may be modified with true or false
Adding and Removing Privileges
Local user account privileges may be modified with a PATCH to the URI of the desired ManagerAccount
resource, as shown in the example in the right pane.
PATCH /redfish/v1/AccountService/Accounts/{accountId}/
{
"Oem": {
"Hpe": {
"Privileges": {
"VirtualMediaPriv": true,
"VirtualPowerAndResetPriv": true
}
}
}
}
Changing Roles
See the example in the right pane.
PATCH /redfish/v1/AccountService/Accounts/{accountId}/
{
"RoleId": "Operator"
}
results in HTTPS status 200:
{
"error": {
"code": "iLO.0.10.ExtendedInfo",
"message": "See @Message.ExtendedInfo for more information.",
"@Message.ExtendedInfo": [
{
"MessageId": "Base.1.0.AccountModified"
}
]
}
}
Changing Password
Local user account passwords may be modified with a PATCH to the URI of the desired ManagerAccount
resource, as shown in the example in the right pane.
PATCH /redfish/v1/AccountService/Accounts/{accountId}/
{
"Password": "newpassword"
}
Removing a Local User Account
A local user account can be removed with a DELETE to the URI of desired ManagerAccount
resource, as shown in the example in the right pane.
DELETE /redfish/v1/AccountService/Accounts/{accountId}/
Directory Authentication
Enabling or Disabling Local User Accounts
See the examples in the right pane for more information.
PATCH /redfish/v1/AccountService/
{
"LocalAccountAuth": "Disabled"
}
or
json { "LocalAccountAuth": "Enabled" }
Note: Disabling local user accounts is not allowed if both Directory Authentication and Kerberos Authentication are disabled.
Configuring Active Directory Authentication
See the examples in the right pane for examples of configuring active directory authentication.
PATCH /redfish/v1/AccountService/
Example 1 (Using default Active Directory server port 636):
{
"LDAP": {
"ServiceEnabled": true,
"ServiceAddresses": [
"<Active Directory Server host name>"
]
}
}
Example 2 (Using explicit/custom Active Directory server port):
{
"LDAP": {
"ServiceEnabled": true,
"ServiceAddresses": [
"<Active Directory Server host name>:4646"
]
}
}
Configuring LDAP Authentication
See the examples in the right pane for examples of configuring LDAP authentication.
PATCH /redfish/v1/AccountService/
Example 1 (Using default OpenLDAP server port 636):
{
"LDAP": {
"AccountProviderType": "LDAPService",
"ServiceEnabled": true,
"ServiceAddresses": [
"<LDAP Server host name>"
]
}
}
Example 2 (Using explicit/custom OpenLDAP server port):
{
"LDAP": {
"AccountProviderType": "LDAPService",
"ServiceEnabled": true,
"ServiceAddresses": [
"<LDAP Server host name>:4646"
]
}
}
Disable Active Directory and LDAP Authentication (Generic LDAP)
See the example in the right pane for more information.
PATCH /redfish/v1/AccountService/
{
"LDAP": {
"AccountProviderType": "ActiveDirectoryService",
"ServiceEnabled": false,
}
}
Enable and Configure HPE Extended Schema Authentication (for Active Directory only)
See the example in the right pane for more information.
PATCH /redfish/v1/AccountService/
{
"LDAP": {
"ServiceEnabled": true,
"ServiceAddresses": [
"<Active Directory Server host name>"
],
"Authentication": {
"Username": "CN=testdevice,CN=Users,DC=ilotest2,DC=com"
}
},
"Oem": {
"Hpe": {
"DirectorySettings": {
"LdapAuthenticationMode": "ExtendedSchema"
}
}
}
}
Add User Search Contexts
See the examples in the right pane for more information.
PATCH /redfish/v1/AccountService/
Sample Payload-1 (Add two new User Search Contexts, with no existing User Search Context present):
{
"LDAP": {
"LDAPService": {
"SearchSettings": {
"BaseDistinguishedNames": [
"CN=Users,DC=domain,DC=com",
"DC=domain,DC=com"
]
}
}
}
}
Sample Payload-2 (Add a new User Search Context, with two existing User Search Contexts present):
{
"LDAP": {
"LDAPService": {
"SearchSettings": {
"BaseDistinguishedNames": [
"CN=Users,DC=domain,DC=com",
"DC=domain,DC=com",
"DC=testdomain,DC=com"
]
}
}
}
}
Delete User Search Contexts
See the examples in the right pane for more information.
PATCH /redfish/v1/AccountService/
Sample Payload-1 (To delete one/multiple User Search Contexts):
Assume you have three existing User Search Contexts, e.g. “CN=Users,DC=domain,DC=com”, “DC=domain,DC=com” and “DC=testdomain,DC=com”. To delete one, exclude it from the payload and keep the ones to be retained.
{
"LDAP": {
"LDAPService": {
"SearchSettings": {
"BaseDistinguishedNames": [
"CN=Users,DC=domain,DC=com",
"DC=domain,DC=com"
]
}
}
}
}
Sample Payload-2 (To delete all User Search Contexts):
{
"LDAP": {
"LDAPService": {
"SearchSettings": {
"BaseDistinguishedNames": [
""
]
}
}
}
}
Import LDAP Server CA Certificate
See the example in the right pane for more information.
POST /redfish/v1/AccountService/ExternalAccountProviders/LDAP/Certificates/
{
"CertificateString": "-----BEGIN CERTIFICATE-----
MIIEHTCCAwWgAwIBAgIQe8LmWgF5edKw01/avJg69DANBgkqhkiG9w0BAQsFADCB
…………………………………………………………………………………………………………………………………
…………………………………………………………………………………………………………………………………
Ow==
-----END CERTIFICATE-----"
}
View LDAP Server CA Certificate Status
See the example in the right pane for more information.
GET /redfish/v1/AccountService/
The property Oem/Hpe/DirectorySettings/LdapCaCertificateLoaded
indicates the status of the certificate.
View LDAP Server CA Certificate Details
GET /redfish/v1/AccountService/ExternalAccountProviders/LDAP/Certificates/{certId}/
NOTE: The LDAP provider supports a single certificate.
{
"@odata.context": "/redfish/v1/$metadata#Certificate.Certificate",
"@odata.etag": "W/\"A1110A63\"",
"@odata.id": "/redfish/v1/AccountService/ExternalAccountProviders/LDAP/Certificates/1/",
"@odata.type": "#Certificate.v0_9_0.Certificate",
"Id": "1",
"Issuer": "/C=US/O=Hewlett Packard Enterprise Company/OU=Infrastructure Services/CN=Hewlett Packard Enterprise Private Root CA",
"Name": "LDAP Certificate",
"SerialNumber": "7BC2E65A017979D2B0D35FDABC983AF4",
"Subject": "/C=US/O=Hewlett Packard Enterprise Company/OU=Infrastructure Services/CN=Hewlett Packard Enterprise Private Root CA",
"ValidNotAfter": "2025-03-16T23:59:59Z",
"ValidNotBefore": "2015-03-17T00:00:00Z"
}
Add new Directory Groups (No Existing Groups)
See the example in the right pane for more information.
PATCH /redfish/v1/AccountService/
Sample Payload: “Administrator” and “Operator” are predefined Redfish RoleIds. “LDAP” can also be used instead of “ActiveDirectory”.
{
"ActiveDirectory": {
"RemoteRoleMapping": [
{
"LocalRole": "Administrator",
"RemoteGroup": "TestGroup1"
},
{
"LocalRole": "Operator",
"RemoteGroup": "TestGroup2"
}
]
}
}
View Directory Groups
See the example in the right pane for more information.
GET /redfish/v1/AccountService/
See the properties under
RemoteRoleMapping
created by the Add operation (fragment of the response):
{
"RemoteRoleMapping": [
{
"LocalRole": "dirgroup4c6c827762dd20dc530c52ef",
"RemoteGroup": "TestGroup1"
},
{
"LocalRole": "dirgroupeb9a3afc9cd9d126249c3aed",
"RemoteGroup": "TestGroup2"
}
]
}
Add New Directory Groups to Existing Groups
See the example in the right pane for more information.
PATCH /redfish/v1/AccountService/
Assume two directory groups (TestGroup1 and TestGroup2 as in the steps above) are present. Use the LocalRole and RemoteGroup values for the existing directory groups from the step above in the payload. Add an additional group “TestGroup3” with “ReadOnly” Redfish Role. “LDAP” can also be used instead of “ActiveDirectory”.
{
"ActiveDirectory": {
"RemoteRoleMapping": [
{
"LocalRole": "dirgroup4c6c827762dd20dc530c52ef",
"RemoteGroup": "TestGroup1"
},
{
"LocalRole": "dirgroupeb9a3afc9cd9d126249c3aed",
"RemoteGroup": "TestGroup2"
},
{
"LocalRole": "ReadOnly",
"RemoteGroup": "TestGroup3"
}
]
}
}
Delete Directory Groups
See the example in the right pane for more information.
PATCH /redfish/v1/AccountService/
Sample Payload-1 (To delete one/multiple Directory Groups): Assume you have three existing directory groups, e.g. “TestGroup1”, “TestGroup2” and “TestGroup3”. To delete “TestGroup3”, exclude it from the payload and keep the ones to be retained. “LDAP” can also be used instead of “ActiveDirectory”.
{
"ActiveDirectory": {
"RemoteRoleMapping": [
{
"LocalRole": "dirgroup4c6c827762dd20dc530c52ef",
"RemoteGroup": "TestGroup1"
},
{
"LocalRole": "dirgroupeb9a3afc9cd9d126249c3aed",
"RemoteGroup": "TestGroup2"
}
]
}
}
Sample Payload-2 (To delete all Directory Groups): “LDAP” can also be used instead of “ActiveDirectory”.
{
"ActiveDirectory": {
"RemoteRoleMapping": [
{}
]
}
}
View Directory Group Privileges
See the example in the right pane for more information.
GET /redfish/v1/AccountService/Roles/
{
"@odata.context": "/redfish/v1/$metadata#RoleCollection.RoleCollection",
"@odata.etag": "W/\"08A22FCA\"",
"@odata.id": "/redfish/v1/AccountService/Roles/",
"@odata.type": "#RoleCollection.RoleCollection",
"Description": "iLO Roles Collection",
"Name": "Roles",
"Members": [
{
"@odata.id": "/redfish/v1/AccountService/Roles/Administrator/"
},
{
"@odata.id": "/redfish/v1/AccountService/Roles/Operator/"
},
{
"@odata.id": "/redfish/v1/AccountService/Roles/ReadOnly/"
},
{
"@odata.id": "/redfish/v1/AccountService/Roles/dirgroup4c6c827762dd20dc530c52ef/"
},
{
"@odata.id": "/redfish/v1/AccountService/Roles/dirgroupeb9a3afc9cd9d126249c3aed/"
}
],
"Members@odata.count": 5
}
GET /redfish/v1/AccountService/Roles/{directoryGroupId}/
{
"@odata.context": "/redfish/v1/$metadata#Role.Role",
"@odata.etag": "W/\"D17157B3\"",
"@odata.id": "/redfish/v1/AccountService/Roles/dirgroup4c6c827762dd20dc530c52ef/",
"@odata.type": "#Role.v1_2_1.Role",
"Id": "dirgroup4c6c827762dd20dc530c52ef",
"AssignedPrivileges": [
"Login",
"ConfigureSelf",
"ConfigureManager",
"ConfigureUsers"
],
"Description": "iLO Directory Group Role",
"IsPredefined": false,
"Name": "Group Role",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeDirectoryGroup.HpeDirectoryGroup",
"@odata.type": "#HpeDirectoryGroup.v1_0_0.HpeDirectoryGroup",
"GroupDn": "TestGroup1",
"GroupSid": ""
}
},
"OemPrivileges": [
"RemoteConsolePriv",
"VirtualMediaPriv",
"VirtualPowerAndResetPriv",
"HostBIOSConfigPriv",
"HostNICConfigPriv",
"HostStorageConfigPriv"
],
"RoleId": "dirgroup4c6c827762dd20dc530c52ef"
}
Modify Directory Group Privileges
See the examples in the right pane for more information.
PATCH /redfish/v1/AccountService/Roles/{directoryGroupId}/
Sample Payload-1 (Update AssignedPrivileges): Add/Remove the privileges in the AssignedPrivileges[] array.
{
"AssignedPrivileges": [
"Login",
"ConfigureSelf",
"ConfigureUsers"
]
}
Sample Payload-2 (Update OemPrivileges): Add/Remove the privileges in the OemPrivileges[] array.
{
"OemPrivileges": [
"RemoteConsolePriv",
"VirtualPowerAndResetPriv",
"HostNICConfigPriv",
"HostStorageConfigPriv"
]
}
Enable, Configure, Disable Kerberos Authentication
See the examples in the right pane for more information.
PATCH /redfish/v1/AccountService/
Disable
{
"ActiveDirectory": {
"ServiceEnabled": false
}
}
Enable Sample Payload-1 (Using default KDC server port 88):
Where
“TESTKDCREALM.COM”
is the Kerberos Realm.
{
"ActiveDirectory": {
"ServiceEnabled": true,
"ServiceAddresses": [
"testkdc.hpe.com@TESTKDCREALM.COM"
]
}
}
Enable Sample Payload-2 (Using explicit/custom KDC server port):
{
"ActiveDirectory": {
"ServiceEnabled": true,
"ServiceAddresses": [
"testkdc.hpe.com:8888@TESTKDCREALM.COM"
]
}
}
Import Kerberos Keytab File
See the example in the right pane for more information.
POST /redfish/v1/AccountService/Actions/Oem/Hpe/HpeiLOAccountService.ImportKerberosKeytab/
{
"ImportUri": "http://<URI of keytab file>"
}
Start Directory Test
See the examples in the right pane for more information.
POST on /redfish/v1/AccountService/DirectoryTest/Actions/HpeDirectoryTest.StartTest/
Sample Payload-1 (No parameters):
{
}
Sample Payload-2 (with Test User Name and password):
{
"TestUserName": "TestUser1",
"TestUserPassword": "TestPassword1"
}
Sample Payload-3 (with all parameters):
{
"TestUserName": "TestUser1",
"TestUserPassword": "TestPassword1",
"DirectoryAdminDn": "CN=Administrator,CN=Users,DC=ilotest2,DC=com",
"DirectoryAdminPassword": "AdminPassword"
}
Stop Directory Test
See the example in the right pane for more information.
POST /redfish/v1/AccountService/DirectoryTest/Actions/HpeDirectoryTest.StopTest/
(empty payload)
{
}
View Directory Test Result
See the example in the right pane for more information.
GET /redfish/v1/AccountService/DirectoryTest/
{
"@odata.context": "/redfish/v1/$metadata#HpeDirectoryTest.HpeDirectoryTest",
"@odata.etag": "W/\"6B3F28F1\"",
"@odata.id": "/redfish/v1/AccountService/DirectoryTest/",
"@odata.type": "#HpeDirectoryTest.v1_0_0.HpeDirectoryTest",
"Id": "DirectoryTest",
"Actions": {
"#HpeDirectoryTest.StartTest": {
"target": "/redfish/v1/AccountService/DirectoryTest/Actions/HpeDirectoryTest.StartTest/"
},
"#HpeDirectoryTest.StopTest": {
"target": "/redfish/v1/AccountService/DirectoryTest/Actions/HpeDirectoryTest.StopTest/"
}
},
"OverallStatus": "NotRun",
"TestResults": [
{
"Notes": "",
"Status": "NotRun",
"TestName": "Directory Server DNS Name"
},
{
"Notes": "",
"Status": "NotRun",
"TestName": "Ping Directory Server"
},
{
"Notes": "",
"Status": "NotRun",
"TestName": "Connect to Directory Server"
},
{
"Notes": "",
"Status": "NotRun",
"TestName": "Connect using SSL"
},
{
"Notes": "",
"Status": "NotRun",
"TestName": "Bind to Directory Server"
},
{
"Notes": "",
"Status": "NotRun",
"TestName": "Directory Administrator login"
},
{
"Notes": "",
"Status": "NotRun",
"TestName": "User Authentication"
},
{
"Notes": "",
"Status": "NotRun",
"TestName": "User Authorization"
},
{
"Notes": "",
"Status": "NotRun",
"TestName": "Directory User Contexts"
},
{
"Notes": "",
"Status": "NotRun",
"TestName": "LOM Object exists"
}
]
}
Implementation of Two Factor Authentication (TFA) in Redfish
Two Factor Authentication is a security feature that enhances security while logging in and creating a user session. TFA uses a One Time Password (OTP) token along with the username and password credentials. When a Microsoft Active Directory user logs in, the user needs to provide the 6 digit token (OTP) received over email.
Two Factor Authentication (TFA) is applicable for Microsoft Active Directory users when enabled
.
Pre-requisites for using Two Factor Authentication
- Both
TwoFactorAuth
andSMTPForTFAEnabled
must beenabled
andtrue
respectively. - To enable
TwoFactorAuth
, the following should be enabled:LDAPAuthenticationMode
LDAPService
SMTPForTFAEnabled
Enabling SMTP For Two Factor Authentication
SMTPForTFAEnabled
indicates SMTP for Two Factor Authentication (TFA). Perfom GET
on /redfish/v1/AccountService
. The supported values are Enabled
and Disabled
.
NOTE: To enable SMTPForTFAEnabled
, AlertMailSenderDomain
and AlertMailSMTPServer
should be set correctly.
GET /redfish/v1/AccountService
{
"SNMPService": {
"@odata.id": "/redfish/v1/Managers/1/SnmpService"
},
"RemoteSyslogEnabled": false,
"RemoteSyslogPort": 514,
"RemoteSyslogServer": "stuv",
"SMTPForTFAEnabled": false,
"SNMPTrapPort": 162,
"SerialOverLanLogging": false,
"VirtualMediaEncryptionEnabled": true,
"WebProxyConfiguration": {
"ProxyPassword": null,
"ProxyPort": null
}
}
To enable SMTPForTFAEnabled
, perform PATCH
on /redfish/v1/Managers/1/NetworkProtocol
. The supported values are true
and false
.
PATCH /redfish/v1/Managers/1/NetworkProtocol
PATCH Payload
{
"Oem": {
"Hpe": {
"SMTPForTFAEnabled": "true"
}
}
}
{
"error":{
"code": "iLO.0.10ExtendedInfo",
"message": "See @Message.ExtendedInfo for more information",
"@Message.ExtendedInfo": {
"MessageId": "Base.1.4.Success"
}
}
}
Enabling Two Factor Authentication
TwoFactorAuth
indicates if Two Factor Authentication (TFA) is enabled or not. Perform GET
on /redfish/v1/AccountService
. The supported values are Enabled
and Disabled
.
NOTE: Attempting to authenticate using Basic-Auth
when TFA is enabled
will result in a 401 Unauthorized No Valid Session
response if the user account used is a Microsoft Active Directory user.
GET /redfish/v1/AccountService
{
"DirectorTest" : {
"@odata.id": "/redfish/v1/AccountService/DirectoryTest"
},
"EnforcePasswordComplexity": false,
"KerberosSettings": {
"KDCServerPort": 88,
"KerberosRealm": "ILOQA.COM"
},
"MinPasswordLength": 8,
"TwoFactorAuth": "Enabled"
}
To enable or disable TwoFactorAuth
, perform PATCH
on /redfish/v1/AccountService
. The supported values are Enabled
and Disabled
.
PATCH /redfish/v1/AccountService
PATCH Payload
{
"Oem": {
"Hpe": {
"TwoFactorAuth": "Enabled"
}
}
}
{
"error":{
"code": "iLO.0.10ExtendedInfo",
"message": "See @Message.ExtendedInfo for more information",
"@Message.ExtendedInfo": {
"MessageId": "Base.1.4.Success"
}
}
}
NOTE : Both TwoFactorAuth
and SMTPForTFAEnabled
should be enabled
and true
respectively to enable Two Factor Authentication.
Creating a User Session
When Two Factor Authentication is enabled
and the Microsoft Active Directory user credentials are entered, a OneTimePasscodeSent
response message appears and an One Time Password (OTP) will be sent to the configured Microsoft Active Directory user email id.
To obtain the One Time Password (OTP) perform POST
on /redfish/v1/Sessions
POST /redfish/v1/Sessions
POST Payload
{
"UserName": "jason",
"Password": "words123"
}
{
"error":{
"code": "iLO.0.10ExtendedInfo",
"message": "See @Message.ExtendedInfo for more information",
"@Message.ExtendedInfo": [
{
"MessageArgs": [
"configured mail"
],
"MessageId": "Base.1.17.OneTimePasscodeSent"
}
]
}
}
This OTP is entered in the POST
payload as a Token
along with the Microsoft Active Directory user credentials.
The Token is 6 digit positive non-zero integer value.
POST /redfish/v1/Sessions
POST Payload
{
"UserName": "jason",
"Password": "words123",
"Token": "123456"
}
{
"@odata.context": "/redfish/v1/$metadata#Session.Session",
"@odata.etag": "W/_\"3F61854C",
"@odata.id": "/redfish/v1/SessionService/Sessions/fewe0000648857f74474c42",
"@oata.type": "Session.v1_0_0.Session",
"Id": "jason0000648857f74474c42"
}
Managing Time in iLO 6
iLO 6 obtains the date and time from one of several sources and is not manually configurable.
- Network Time Protocol (NTP) Servers
- System UEFI during Boot
- BladeSystem C-Class Onboard Administrator
The configurable iLO 6 Time/Date related configuration properties are:
- Time zone
- Network Time Protocol Server addresses
- Option to synchronize the host to iLO 6’s date and time during first boot after AC power is applied (
PropagateTimeToHost
boolean)
iLO 6 Date and Time
iLO 6 current date and time is available in the main Manager
resource at /redfish/v1/Managers/{id}
GET /redfish/v1/Managers/{id}
"DateTime": "2019-01-06T17:11:53Z",
"DateTimeLocalOffset": "-06:00",
Date/Time Service Resource
A link exists in /redfish/v1/Managers/{id}
to the iLO 6 Date/Time Service. See Oem/Hpe/Links/DateTimeService
. This points to a DateTime
resource at /redfish/v1/Managers/{id}/DateTime
.
Time Zone Management
Time Zone configuration is performed with a PATCH to the DateTime
resource at /redfish/v1/Managers/{id}/DateTime
.
The available time zones are available in the TimeZoneList
property. Take note of the Index
value of the time zone you wish iLO 6 to be configured with. Then PATCH
the TimeZone.Index
property:
PATCH /redfish/v1/Managers/{id}/DateTime
{
"TimeZone": {
"Index": 4
}
}
If the operation is successful, iLO 6 will respond with HTTP 200 OK
and ResetRequired
. An iLO 6 reset is required for date and time operations to be applied. After a successful PATCH the ConfigurationSettings
property will contain SomePendingReset
indicating that some settings have changed but will not take effect until iLO 6 is reset.
If the time zone is configured to be managed by DHCP, iLO 6 will respond with HTTP 400
and SNTPConfigurationManagedByDHCPAndIsReadOnly
(see Using DHCP Supplied Time Settings).
Configuring Network Time Protocol (NTP)
The currently configured Network Time Protocol (NTP) servers are available in the DateTime
resource at /redfish/v1/Managers/{id}/DateTime
.
GET /redfish/v1/Managers/{id}/DateTime
{
"NTPServers": [
"<NTP server 1>",
"<NTP server 2>"
]
}
If NTP is not being managed by DHCP, you may PATCH server addresses into the StaticNTPServers
array.
PATCH /redfish/v1/Managers/{id}/DateTime
{
"StaticNTPServers": [
"<NTP server 1>",
"<NTP server 2>"
]
}
or to set one address
{
"StaticNTPServers": [
"<NTP server 1>"
]
}
If the operation is successful, iLO 6 will respond with HTTP 200 OK
and ResetRequired
. An iLO 6 reset is required for date and time operations to be applied. After a successful PATCH the ConfigurationSettings
property will contain SomePendingReset
indicating that some settings have changed but will not take effect until iLO 6 is reset.
If the time zone is configured to be managed by DHCP, iLO 6 will respond with HTTP 400
and SNTPConfigurationManagedByDHCPAndIsReadOnly
(see Using DHCP Supplied Time Settings).
Example Use Cases
NOTE: The examples in this section use a pseudo-code syntax for clarity. JSON pointer syntax is used to indicate specific properties.
Changing Boot Settings
UEFI boot structured name string
This UEFI boot structured name string is unique and represents each UEFI boot option in the system. Software can identify and manipulate devices using the string’s fixed format as defined in this specification. Software can assume that the string unique for each boot device in the UEFI BootOrder.
The UEFI boot structured name string is divided into sections separated by ‘.’ characters, using the following format:
- DeviceType: The first section describes the device type (For example,
HD,
CD,
NIC,
andPCI.
). - Location: The second and the third section together describes the location of the device
(for example,
Slot.7
orEmb.4
). - Instance: The third section is used with the
Location
section to describe the device location (for example, the slot number or embedded instance number). - Sub-instance: The fourth section is optional, and is used as a sub-instance number in case of multiple boot options using the same instance. For example, this can be the port number for a multi-port NIC.
- Qualifier: The fifth section is optional, and describes the logical protocol (for example, IPv4, IPv6, and iSCSI).
UEFI boot structured name string examples
Table 1 Examples
Name | Description |
---|---|
HD.Emb.4.2 | The second instance of a hard drive in embedded SA controller bay 4 |
NIC.Slot.7.2.IPv4 | Port 2 of a NIC in PCIe slot 7, which is enabled for PXE IPv4 |
NIC.FlexLOM.1.1.IPv6 | Port 1 of an embedded NIC FlexLOM, which is enabled for PXE IPv6 |
PCI.Slot.6.1 | PCIe card in slot 6 |
HD.FrontUSB.2.2 | Second partition of a flash drive in front USB port 2 |
Table 2 Examples of currently supported Structured Boot Strings
Device Type | Location | Instance | Sub instance | Qualifier | Structure Boot String Examples |
---|---|---|---|---|---|
Smart Array Hard Drive | Embedded | Bay number | Incremental by LUN | HD.Emb.1.1 | |
Slot | Slot number | Incremental by LUN | HD.Slot.1.1 | ||
Smart Array Controller | Embedded | Controller Instance | 1 | RAID.Emb.1.1 | |
Slot | Slot number | 1 | RAID.Slot.1.1 | ||
Dynamic Smart Array Controller (Software RAID) | Embedded | 1 | 1 | Storage.Emb.1.1 | |
Slot | Controller Instance | 1 | Storage.Slot.1.1 | ||
SATA Hard Drive | Embedded | SATA port # 1 | HD.Emb.1.1 | ||
SATA Controller | Embedded | Controller Instance | 1 | SATA.Emb.1.1 | |
All other storage controllers (FC, SAS, etc…) | Embedded | 1 | 1 | Storage.Emb.1.1 | |
Slot | Slot # | 1 | Storage.Slot.1.1 | ||
Network Adapter | LOM | NIC number, 1 for 1st NIC, 2 for 2nd NIC | Port number | IPv4 or IPv6 or iSCSI or FCoE | NIC.LOM.1.2.IPv4, NIC.LOM.1.2.IPv6 |
FlexibleLOM | FlexibleLOM number, 1 for 1st FlexLOM, 2 for 2nd FlexLOM | Port Number | IPv4 or IPv6 or iSCSI or FCoE | NIC.FlexLOM.2.1.IPv4, NIC.FlexLOM.2.1.IPv6 | |
Slot | Slot Number | Port number | IPv4 or IPv6 or iSCSI or FCoE | NIC.Slot.3.2.Ipv4 | |
Fiber Channel Adapter | Slot | Slot number | Port number | IPv4 or IPv6 or iSCSI or FCoE | PCI.Slot.3.1 |
OS Boot entry (such as Embedded HD.Slot.1.2 “Windows Boot Manager”) | Slot | Embedded | Incremental | HD.Emb.1.2, HD.Slot.1.2 | |
USB Key | Front USB | USB Port # | Incremental by LUN | HD.FrontUSB.1.1 | |
Rear USB | USB Port # | Incremental by LUN | HD.RearUSB.1.1 | ||
Internal USB | USB Port # | HD.InternalUSB.1.1 | |||
iLO virtual media | HD.Virtual.1.1 | ||||
ISO image | iLO virtual media | CD.Virtual.2.1 | |||
Virtual Install Disk (VID) | Embedded store | USB Port # | HD.VirtualUSB.1.1 | ||
Embedded User Partition | Embedded store | USB Port # | HD.VirtualUSB.2.1 | ||
USB CD/DVD | Front USB | USB Port # | CD.FrontUSB.1.1 | ||
Rear USB | USB Port # | CD.RearUSB.1.1 | |||
Internal USB | USB Port # | xxxxxxxx | |||
SD card | SD slot | USB Port # | HD.SD.1.1 | ||
Floppy | Front USB, Rear USB | USB Port # | FD.FrontUSB.1.1, FD.RearUSB.1.1 | ||
Embedded UEFI Shell | Embedded | 1 | 1 | Shell.Emb.1.1 | |
UEFI applications (embedded in the ROM firmware) (Diag, System Utility, etc..) | Embedded | 1 | Incremental | App.Emb.1.1, App.Emb.1.2, App.Emb.1.3 | |
File | URL | Different URL Increased by 1 | 1 | File.URL.1.1 | |
HPE RAM Disk Device | RAM Memory | 1 | Port Number | RAMDisk.Emb.1.1 | |
Special USB device class with Device Path: UsbClass(0xFFFF, 0xFFFF, 0xFF, 0xFF, 0xFF) | Any USB device in the system | 1 | Generic.USB.1.1 | ||
Empty slot, no device | Slot | Slot number | 1 | PCI.Slot.2.1 | |
Unknown device | Embedded Slot Unknown location | Slot number or 1 | Incremental | Unknown.Slot.1.1, Unknown.Unknown.1.1 | |
NVMe | Slot | Slot number | NVMe drive number (The number is based on bus enumeration sequence). | NVMe.Slot.1.1 | |
NVMe | Embedded | Bay number | 1 (Each drive bay has 1 NVMe drive.) | NVMe.Emb.1.1 |
Change UEFI boot order example
For more information click on the python tab.
For a full Redfish example click here: change_boot_order.py
The BIOS current configuration object contains a link to a separate read-only resource of type HpeServerBootSettings
that lists the UEFI Boot Order current configuration. This is the system boot order when the system is configured in the UEFI Boot Mode. The UEFI Boot Order current configuration resource contains a BootSources
property, which is an array of UEFI boot sources. Each object in that array has a unique StructuredBootString,
among other properties that identify that boot source.
The UEFI boot order list itself is represented in a separate PersistentBootConfigOrder
property that is an ordered array of boot sources, each referenced by its StructuredBootString
. In addition, a DesiredBootDevices
property lists a separate ordered list of desired boot sources that might not be listed in the BootSources
property. This is useful for configuring boot from a specific SCSI or FC LUN or iSCSI target that might have not been configured (and discovered by BIOS) yet.
As with the BIOS current configuration resource, the UEFI Boot Order current configuration resource is read only (as evident by the allow header, which do not list PATCH
as an allowed operation). To change the UEFI Boot Order, you need to follow the link to a separate Settings resource that you can perform a PATCH
operation on that contains the pending UEFI Boot Order settings, and update that PersistentBootConfigOrder
and/or the DesiredBootDevices
properties in that Settings resource. The settings remain pending until next reboot, and the results are reflected back in the @Redfish.Settings
property in the UEFI Boot Order current configuration resource.
Prerequisites: Minimum required session ID privileges: Configure
- Iterate through
/redfish/v1/Systems/
and choose a memberComputerSystem
. Find a child resource of typeHpeServerBootSettings
that allowsPATCH
operations (there might be more than one, but for this exercise, choose the first one).{ilo-ip-address}/redfish/v1/Systems/1/BIOS/Boot/Settings/
- Obtain the UEFI boot order.
GET {ilo-ip-address}/redfish/v1/Systems/1/BIOS/Boot/Settings/
- Create a new JSON object with the
PersistentBootConfigOrder
property and change the boot order. - Change the UEFI boot order. You only need to send the updated
PersistentBootConfigOrder
property in the request body.PATCH {ilo-ip-address}/redfish/v1/Systems/1/BIOS/Boot/Settings/
When the sever is reset, the new boot order is validated and used.
Reset a Server
Server power control is a system-node-level entity, not a chassis-level control. For example, you can turn on one node in a multi-node chassis. You control power by performing an HTTP operation on a computer system node object.
Some operations in the interface are not truly RESTful GET,
PUT,
POST,
DELETE,
or PATCH.
They are called custom actions and are performed with an HTTP POST
containing a specific request payload. Typically, actions are defined when the action you want to perform is not adequately represented by the properties available in the type. For example, a power button is not readable, so you cannot GET
the status of the power button. In this case, pressing the power button is an action.
Actions are POST
operations with an Action
property that names the action to perform and zero or more parameter properties.
Reset a server example
curl --header "Content-Type: application/json" --request POST --data '{"ResetType": "ForceRestart"}' https://{iLO}/redfish/v1/Systems/1/Actions/ComputerSystem.Reset -u username:password --insecure
Prerequisites
Minimum required session ID privileges: Configure
- Iterate through
/redfish/v1/Systems
collection and choose a memberComputerSystem
that allowsPOST
operations.{ilo-ip-address}/redfish/v1/Systems/1
- Get the “Actions” -> “#ComputerSystem.Reset” -> “target” Uri.
- Construct an Action object to submit to iLO.
{"ResetType":"ForceRestart"}
- Reset the server by posting the body to the target Uri.
POST {ilo-ip-address}/redfish/v1/Systems/1/Actions/ComputerSystem.Reset/
The server resets and reboots.
Download Active Health System Data
For more information click on the python tab.
For a full Redfish example click here: get_ahs_data.py
Active Health System (AHS) data may be accessed by first discovering the resource of type HpiLOActiveHealthSystem
. This is typically at https://{iLO}/redfish/v1/managers/{item}/activehealthsystem/
. Refer to the section on Iterating Collections for details on how to navigate the data model.
- Iterate the Managers collection at
https://{iLO}/redfish/v1/managers/
. For traditional iLO-based server architectures there is a single manager representing iLO 6 itself. - Find the
Link
property referring to theHpiLOActiveHealthSystem
and follow that link. - GET the
HpiLOActiveHealthSystem
resource and look for the URI indicated byLinks.AHSLocation.extref
. - Perform a GET to this URI with the following query parameters to define the download time range and embed customer case information:
from
: the starting date of the download range (in YYYY-MM-DD format)to
: the ending date of the download range (in YYYY-MM-DD format)case_no
: case identification stringco_name
: company or organization namecontact
: contact nameemail
: contact email addressphone
: contact phone number
If successful, the response is an HTTP 200 level status code and a binary download which can be saved to a file.
Finding the iLO mac address
For more information click on the python tab.
For a full Redfish example click here: find_ilo_mac_address.py
Before you search for the iLO mac address, you must create an instance of a RestObject
or RedfishObject
. The class constructor takes the iLO hostname/IP address, iLO login username, and password as arguments. The class also initializes a login session, gets systems resources, and message registries.
Adding an iLO user account
For more information click on the python tab.
For a full Redfish example click here: add_user_account.py
Before you add an iLO user account, you must create an instance of a RestObject
or RedfishObject
. The class constructor takes the iLO hostname/IP address, iLO login username, and password as arguments. The class also initializes a login session, gets systems resources, and message registries.
Setting a license key
curl -H "Content-Type: application/json" -X POST --data "@data.json" https://{iLO}/redfish/v1/Managers/1/LicenseService/ -u username:password --insecure
Contents of data.json
{“LicenseKey”: “xxxxx-xxxxx-xxxxx-xxxxx-xxxxx”}
For a full Redfish example click here: set_license_key.py
Before you set a license key, you must create an instance of a RestObject
or RedfishObject
. The class constructor takes the iLO hostname/IP address, iLO login username, and password as arguments. The class also initializes a login session, gets systems resources, and message registries.
Changing an iLO user account
For more information click on the python tab.
For full Redfish examples click here: modify_user_account.py, remove_account.py
Before you change an iLO user account, you must create an instance of a RestObject
or RedfishObject
. The class constructor takes the iLO hostname/IP address, iLO login username, and password as arguments. The class also initializes a login session, gets systems resources, and message registries.
Chunked Transfer Coding
iLO 6 responds to all HTTP operations using Chunked Transfer Coding. This enables features like $expand
that require very large responses.
URI Remapping from /rest to /redfish
For iLO 6, accesses to the /rest/v1/x
URI pattern result in HTTP 308 redirect to /redfish/v1/x/
. Additionally, access to /redfish/v1/x
redirects to /redfish/v1/x/
.
OData-Version HTTP Header Requirements
iLO 6 assumes all requests to Redfish REST resources are Redfish requests. The service does not behave differently based upon the presence or absence of the OData-Version
header.
The only required header for a GET operation is the authorization (X-Auth-Token
or Authorization
) header, except for the root resource at /redfish/v1/
which requires no headers.
Schema Type Changes
To preserve OData conformance, Redfish transitioned the format of @odata.type
properties, and iLO 6 follows this change. The type.<major>.<minor>.<errata>.type
format has changed to type.v<major>_<minor>_<errata>.type
. Also, the type name cannot be parsed programmatically and should be considered opaque. To determine the version of a resource, do not split the type/version by the ‘.’ delimiter.
For example:
iLO | @odata.type Format |
---|---|
iLO 6 | "@odata.type": "ComputerSystem.v1_17_0.ComputerSystem" |
POST Actions
In Redfish, an "Actions"
property informs the client which actions are supported on a resource and how to invoke them.
Advertising Available Actions
The pre-Redfish form of advertising Available Actions is replaced in iLO 6 with Redfish Actions
.
iLO 6 example of advertised action:
{
"Actions": {
"#ComputerSystem.Reset": {
"target": "/redfish/v1/Systems/1/Actions/ComputerSystem.Reset",
"ResetType@Redfish.AllowableValues": [
"On",
"ForceOff",
"GracefulRestart",
"ForceRestart",
"Nmi",
"GracefulRestart",
"ForceOn",
"PushPowerButton"
]
}
}
}
Invoking Actions
iLO 6 action invoke example:
POST /redfish/v1/Systems/1/Actions/ComputerSystem.Reset
{
"ResetType": "On"
}
Note that the URI of the POST matches the "target"
property in "Actions"
.
iLO 6 Data Model Changes
ServiceRoot (/redfish/v1/
)
TrustedModules (TPM)
Output example
"TrustedModules": [
{
"FirmwareVersion": "1.257",
"InterfaceType": "TPM2_0",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeTrustedModuleExt.HpeTrustedModuleExt",
"@odata.type": "#HpeTrustedModuleExt.v2_0_0.HpeTrustedModuleExt",
"VendorName": "STMicro"
}
},
"Status": {
"Health": "OK",
"State": "Enabled"
}
}
]
iLO 6 Security State
Similar to iLO 5, iLO 6 features the security state setting ("SecurityState"
) readable and settable via the REST API.
{
"Oem": {
"Hpe": {
"SecurityState": "HighSecurity"
}
}
}
The possible values include:
Production
HighSecurity
FIPS
CNSA
You may PATCH these settings, but iLO 6 enforces strict limitations on how security states can transition. Any unsupported transition results in an error.
Allowed Transitions
Transition | Notes |
---|---|
Production <–> HighSecurity | You may transition freely between Production mode and High Security mode, subject to authentication and privileges. |
Production or HighSecurity –> FIPS | You may transition into FIPS mode. Transitions out of FIPS mode are complex and beyond the scope of the RESTful API. |
Impact on Local iLO RESTful API Access (via iLOrest utility and Channel Interface)
Similar to iLO 5, iLO 6 limits access to the local interface in HighSecurity and FIPS modes to authorized users only.
When performing local BIOS configuration changes, the following conditions apply:
Local REST Access | No BIOS Password | BIOS Password Set |
---|---|---|
Production Mode | No authorization required | Requires BIOS Configuration Privilege |
High Security Mode | Requires BIOS Configuration Privilege | Requires BIOS Configuration Privilege |
Remote REST Access | No BIOS Password | BIOS Password Set |
---|---|---|
Production Mode | Requires BIOS Configuration Privilege | Requires BIOS Configuration Privilege |
High Security Mode | Requires BIOS Configuration Privilege | Requires BIOS Configuration Privilege |
Notice that iLO is not validating against the BIOS setup password, but is using the presence of the BIOS password to require BIOS Configuration Privilege.
On-Service JSON Schema
The on-service schema collection remains at /redfish/v1/schema/
and does not change to the Redfish example of /redfish/v1/JsonSchema
. Because URIs are opaque, this is left where it is without violating the spec and preserving compatibility.
The existing collection of SchemaFileCollection
and SchemaFile
resources are now Redfish conformant using JsonSchemaFileCollection
and JsonSchemaFile
.
iLO 5 and iLO 6 |
---|
/redfish/v1/schemas: “@odata.type”: “#JsonSchemaFileCollection.JsonSchemaFileCollection” |
/redfish/v1/schemas/{item}: “@odata.type”: “#JsonSchemaFile.v1_0_0.JsonSchemaFile" |
iLO 6 example:
{
"Uri": "/redfish/v1/registrystore/en/BiosAttributeRegistryP89.v1_0_0.json"
}
On-Service Message Registries
Message Registries available in the service conform to Redfish.
The HpCommon
registry is renamed to HpeCommon
and changed to version 2.0.0.
The iLO registry version is also changed to 2.0.0. The base remains at 1.0.0 because that is a Redfish standard registry.
iLO 6 |
---|
“@odata.type”: “#MessageRegistry.1.0.0.MessageRegistry” |
RegistryVersion |
OwningEntity (== Hewlett Packard Enterprise) |
The collection of Message Registries is listed as:
iLO 5 and iLO 6 @odata.type |
---|
"#MessageRegistryFileCollection.MessageRegistryFileCollection" |
The collection items pointing to the registries change type:
iLO 5 and iLO 6 @odata.type |
---|
"#MessageRegistryFile.1.0.0.MessageRegistryFile" |
The only difference between SchemaFile/JsonSchemaFile and MessageRegistryFile is the property substitution Schema for Registry.
iLO 6 Software/Firmware Update Service
The Redfish standard schema package DSP8010 version 2016.2 introduced the UpdateService
schema, enabling firmware and software inventory, and simple firmware updates. The iLO 6 Update Service is conformant with the UpdateService
schema, but significantly expands the capabilities to include a component repository, an update queue, and install sets.
Concepts and Terms
Term | Definition |
---|---|
Inventory | The installed or running versions of software or firmware. |
Target | The object of a firmware or software update (e.g. BIOS, iLO, Network Adapter, software package). |
Update | The process of applying updated firmware or software to applicable targets. |
Update Agent | The software or firmware agent that applies an update to one or more targets. Update Agents include Smart Update Manager (SUM), UEFI BIOS, and iLO 6. Different types of updates might be supported by specific update agents. |
Activate | The process of making updated firmware of software active (for example, a BIOS update is activated when the server reboots). |
Component | A package containing one or more software or firmware update images (also known as a Smart Component ). Components are typically delivered with the Support Pack for ProLiant (SPP) in EXE, RPM, or ZIP files. |
Component Signature File (.compsig ) |
A file containing information about a component, including a digital signature. This enables iLO to verify the integrity and authenticity of a variety of component formats. The .compsig files are also available with the SPP and must be uploaded with the component. SUM automatically uploads the right .compsig file with components. |
iLO Repository | A persistent storage location on the server that can hold software or firmware update components. |
Update Task Queue | An iLO managed queue of update operations. iLO might not be the actual update agent. Other update agents include Smart Update Manager (SUM) and the UEFI BIOS. |
Install Set | A pre-defined sequence of update tasks managed using the iLO REST API that can be added to the Update Task Queue with an Invoke action. |
Maintenance Window | A defined time window that may be used with an Update Task create or Install Set Invoke commands to associate a time with the operation. |
Redfish Update Service Operations
The Update Service is available as a link (UpdateService
) from the Redfish root resource (/redfish/v1/
). The Update Service complies with the Redfish UpdateService
schema.
Firmware and Software Inventory
The firmware and software inventory is maintained in two separate collections (FirmwareInventory
and SoftwareInventory
). These collections support the iLO 6 $expand
operation, allowing a client to fetch the entire collection with one GET operation.
Each member item conforms to the Redfish SoftwareInventory
schema.
Item (generic) at /redfish/v1/UpdateService/FirmwareInventory/{item}
HTTP Allow: GET
SimpleUpdate Action
The SimpleUpdate
action with the ImageURI
parameter causes iLO to fetch an image from a web server and flash it directly. Only certain types of images may be supplied, including iLO firmware binaries and UEFI firmware binaries. Smart Components are not supported. The list of supported binaries is the same as those that can be updated through iLO’s Web user interface.
Smart Components may be uploaded to the iLO Repository and a task created to cause UEFI or SUM to perform the update.
POST /redfish/v1/UpdateService/Actions/UpdateService.SimpleUpdate/
{
"ImageURI": "<uri to binary image for iLO to flash>"
}
HttpPushUri
The HttpPushUri property indicates the URI to POST a firmware component that iLO can flash. Only certain types of images may be supplied including iLO firmware binaries and UEFI firmware binaries. Smart Components are not supported. The list of supported binaries is the same as those that can be updated through iLO’s Web user interface.
The POST must be of Content-Type: “multipart/form-data”
-----------------------------64062213329524
Content-Disposition: form-data; name="sessionKey"
<value of X-Auth-Token here>
-----------------------------64062213329524
Content-Disposition: form-data; name="<component-filename>"; filename="<component-filename>"
Content-Type: application/octet-stream
<binary image>
iLO validates the uploaded binary image and flashes any applicable targets immediately. If the update is for iLO itself, iLO automatically resets at the end of the flash process and activates the new firmware upon restart.
Software and Firmware Management Flow
Evaluating Current Software and Firmware Inventory to iLO Repository Components
This is the general pseudocode to correlate applicable updates in the iLO Repository to updatable items from the inventory.
- Use the FirmwareInventory and SoftwareInventory data to evaluate the current software and firmware running on the server.
for component in /redfish/v1/updateservice/componentrepository:
for inventory_item in /redfish/v1/updateservice/firmwareinventory:
# if "DeviceClass" is populated in the inventory item
if DeviceClass in inventory_item:
# if present and not matching, move along
if component.DeviceClass != inventory_item.DeviceClass:
continue
# if we made this this far, either inventory item doesn't have DeviceClass or they match
for target in component.Targets:
if target in item.Oem.Hpe.Targets:
return inventory_item, component # return correlated
- Upload new components to the iLO Repository
- Optionally create or modify Install Sets to bundle multiple components in the iLO Repository into an ordered list of update operations.
- Optionally create Maintenance Windows to specify pre-determined time ranges for update tasks to be executed.
- Create tasks individually or Invoke an Install Set to populate the task list. Use either a time range for each task or specify a Maintenance Window to automatically associate the timed window with the created tasks.
- Monitor update operations and handle any errors
- Optionally remove any completed Tasks, Maintenance Windows, Install Sets, or components that are no longer required.
Software and Firmware Management Operations
iLO Repository
The iLO Repository is a persistent storage location for update components including Smart Component files (.EXE
, .RPM
, etc.), as well as raw binary files (.BIN
). Additions to the repository require a digital signature for iLO to verify the integrity and authenticity of the component. For raw .BIN
files, this information is contained within the file. For Smart Components, the information is in a separate Component Signature file (.compsig
) that must be supplied when adding a component.
The Repository is available in the REST API as a child of the Update Service.
- GET root (
/redfish/v1/
). - GET the destination of the
UpdateService
link. - GET the destination of the
Oem/Hpe/ComponentRepository
link.
Additions to the repository are made via the UpdateService
actions. Removals are made by DELETE on repository collection members.
Upload Components
See details on the HttpPushUri in the Update Service resource first. The upload process can alternatively be used to add components to the iLO Repository. As with update, the POST must be a multipart/form-data.
The following HTTP headers must be supplied:
# build the HTTP headers
# 'Content-Type': 'multipart/form-data',
headers = {'Accept': 'application/json',
'Expect':'',
'OData-Version': '4.0',
'X-Auth-Token': sessionkey,
'Cookie': 'sessionKey=' + sessionkey}
The HTTP POST body:
-----------------------------64062213329524
Content-Disposition: form-data; name="sessionKey"
<value of X-Auth-Token here>
-----------------------------64062213329524
Content-Disposition: form-data; name="parameters"
Content-Type: application/json
{
"UploadCurrentEtag": "<client-defined-string>",
}
-----------------------------64062213329524
Content-Disposition: form-data; name="compsig"; filename="compsig-filename"
Content-Type: application/octet-stream
<binary content of component signature file>
-----------------------------64062213329524
Content-Disposition: form-data; name="file"; filename="component-filename"
Content-Type: application/octet-stream
<binary content of component file>
The new compsig
part enables the client to push the component signature file with the payload.
The parameters
part enables clients to add parameters to the upload like execution parameters.
‘parameters’ part in multi-part POST
The following parameters may be specified in a JSON object as part of the upload. All parameters are optional and the ‘Parameters’ multi-part may be optional.
Parameter Name | JSON type | Description |
---|---|---|
UpdateRepository | boolean | If true, adds the component to the repository. This is ignored and assumed true for components flashable by UEFI or SUT/SUM. |
UploadCurrentEtag | string | client-selected-etag-string-reported back in ‘UploadCurrentEtag’ |
UpdateTarget | boolean | If true, iLO immediately flashes the binary. This is ignored and assumed false for components flashable by UEFI or SUT/SUM. |
Section | integer | Section number for huge uploads (see below) starting at 0. |
NOTE: The two free-form parameters, ExecutionParameters
and Configuration
(used by SUM to communicate to the components) are not supplied here, but can be PATCHed later once the components are in the Repository.
iLO self-flash example:
{
"UploadCurrentEtag": "<client-defined-string>",
"UpdateRepository": true,
"UpdateTarget": true
}
Smart Component example:
{
"UploadCurrentEtag": "<client-defined-string>"
}
Waiting for Uploads to Complete
After uploading the component, iLO must verify and write the contents to the repository. The client may track this progress by polling on Oem/Hpe/State
property in the UpdateService
. Values are:
State | Detail |
---|---|
Uploading | iLO is processing the upload - Clients likely won’t see this State because this state occurs during the upload POST. |
Verifying | iLO is verifying the integrity and authenticity of the upload. |
Writing | iLO is writing the upload to the repository. |
Updating | iLO is updating one or more targets applicable to the upload. |
Complete | The operation is complete without errors. |
Error | The operation encountered errors. |
The client should wait for Complete
before progressing.
Inventory Components in iLO Repository
The iLO Repository is a collection that supports the $expand operation. Perform a GET operation on the collection and its members to inventory the repository.
Available data for each member includes:
Property | PATCHable? | Detail |
---|---|---|
Name | No | Component Name |
Filename | No | Unique file name |
Version | No | Version as a string |
SizeBytes | No | Size in Bytes |
Criticality | Yes | Recommended, optional, critical. |
Created | No | Time the component was added to the repository. |
Locked | No | True if the component is referenced by a task or install set. |
ComponentUri | No | URI of the component binary. |
Activates | No | A hint of when a component activates (for example, after reboot). |
Configuration | Yes | For Smart Update Manager use only. |
ExecutionParameters | Yes | The command line passed to the component when launched. |
Remove Components
Perform a DELETE operation on the repository collection member to remove it from the repository.
Free Space
The free and total space of the iLO Repository in bytes is available as part of the Repository Collection.
{
"@odata.context": "/redfish/v1/$metadata#ComponentRepository",
"@odata.etag": "W/\"FF1B13FE\"",
"@odata.id": "/redfish/v1/UpdateService/ComponentRepository/",
"@odata.type": "#HpeComponentCollection.HpeComponentCollection",
"Description": "Component Collection",
"Members@odata.count": 0,
"Name": "Component Collection",
"Oem": {
"Hpe": {
"@odata.type": "#HpeComponentRepositoryInformation.v2_0_0.HpeComponentRepositoryInformation",
"ComponentCount": 0,
"FreeSizeBytes": 1073102848,
"TotalSizeBytes": 1073168384
}
}
}
Correlating Components with Current Software and Firmware Version Inventory
There is not a one-to-one correspondence between installed firmware or software and update components. For example, a component might carry firmware for several network controllers.
This algorithm shows how to correlate current version inventory with available components:
for component in componentrepository:
for inventory_item in inventory:
# if "DeviceClass" is populated in the inventory item
if DeviceClass in inventory_item:
# if present and not matching, move along
if component.DeviceClass != inventory_item.DeviceClass:
continue
# if we made this this far, either inventory item doesn't have DeviceClass or they match
for target in component.Targets:
if target in item.Oem.Hpe.Targets:
return inventory_item, component # return correlated
Tasks
Update Agents and Strong Queue Order
Different updates must be performed in different ways:
- Using iLO 6 over the management network
- During server power on by UEFI BIOS
- Under an Operating System with SUM
The UpdateableBy
property indicates which “update agent” may perform the update.
For an update to be applied to a running operating system, SUM or SUT must run on the OS. SUM/SUT checks for pending tasks that include RuntimeAgent
in the UpdateableBy
property.
For an update to be applied during UEFI POST, UEFI checks for pending tasks that include Uefi
in the UpdateableBy
property.
For an update to be applied any time by iLO, iLO checks for pending tasks that include Bmc
in the UpdateableBy
property. Note that items that are updateable by iLO are never marked as updatable by any other agent.
Because of the strong ordering of the task queue, updaters do not bypass another pending item or exception item to find something to update. This can result in task queue stalls. For example, if the top of the queue is marked as Uefi
update, and the second item is marked RuntimeAgent
, SUM/SUT won’t process their item until the system has rebooted, and UEFI has processed its top item.
Updaters process the queue in order, looking at the task state:
Task State |
Updater Behavior |
---|---|
Pending | Mark as InProgress and begin task. |
InProgress | Do nothing and stop processing the queue - a task item is in progress by another updater (assuming this task is not yours). |
Expired | Do nothing and stop processing the queue - the task item has expired, and because of strong queue ordering, all following tasks are not processed. |
Exception | Do nothing and stop processing the queue - the task item has failed, and because of strong queue ordering, all following tasks are not processed. |
Complete | Iterate to next task and examine its State. |
Canceled | Iterate to next task and examine its State. |
Creating Update Tasks
Create a new Task resource to schedule Update tasks. POST a new task object to the tasks collection pointed to by UpdateService
Oem/Hpe/UpdateTaskQueue
:
Example that enables an component to be updated by either SUM or UEFI:
{
"Name": "Unique Client supplied friendly name of this task item.",
"UpdatableBy": [
"Uefi",
"RuntimeAgent"
],
"Command": "ApplyUpdate",
"Component": "<component-name>",
"TPMOverride": true
}
Example that enables an binary component to be updated by iLO:
{
"Name": "Unique Client supplied friendly name of this task item.",
"UpdatableBy": [
"Bmc"
],
"Command": "ApplyUpdate",
"Component": "<component-name>"
}
This creates a new task in the Pending
state at the end of the queue. If it assigned to the Bmc
and is at the top of the queue, iLO starts operating on it immediately. Otherwise, the new task is operated on as soon as an updater runs and finds the new task.
Creating Scheduled Tasks
A client may specify a time window for a task. Time is always relative to iLO’s clock. Two options exist for creating scheduled tasks: explicit time ranges or Maintenance Windows.
Explicit Time Range: Include StartAfter
and Expire
in Task Create POST
StartAfter
and Expire
are two times that can be included in the task create POST operation. You may specify either or both. Each must be formatted as an ISO 8601 time string.
Tasks in the Pending
state will not begin execution until iLO time is after StartAfter
. If for some reason an update does not start and remains in a Pending
state until after the Expire
time, it will never be executed and the State will be Expired. This can happen for instance if a task is to be executed by UEFI and no reboot happens during the time window.
Maintenance Window
See the section on Maintenance Windows later for more details on the use of Maintenance Windows.
If a client creates a Maintenance Window, this window may be specified (by Id
) in the creation of a task.
Example that uses a Maintenance Window
{
"Name": "Unique Client supplied friendly name of this task item.",
"UpdatableBy": [
"Bmc"
],
"Command": "ApplyUpdate",
"Component": "<component-name>",
"MaintenanceWindow": "<maintenance-window-id>"
}
Creating Wait Tasks
Wait tasks can be used to insert time between two other tasks. The UpdatableBy
property should contain only one update agent chosen based upon the updater that needs the time.
Example that causes UEFI to Wait for 30 seconds:
{
"Name": "Pause 30 seconds",
"UpdatableBy": [
"Uefi"
],
"Command": "Wait",
"WaitTimeSeconds": 30
}
WaitTimeSeconds
can be in the range 0-3600 seconds.s
Retiring and Removing Tasks
The REST client that creates an update task is expected to DELETE the task upon completion after the final status/log information is obtained.
Tasks are removed by performing a DELETE operation on the task collection member. The entire queue can be cleared by deleting all tasks. InProgress
tasks should not be deleted even though the REST API will allow it. This might be useful if the task list is stalled and needs to be cleared.
iLO automatically removes completed tasks (State
is Complete
) after 24 hours, but tasks in any other state are not removed.
Handling Exceptions
If a task cannot complete it will report a State
value of Exception
. Tasks in this state do not automatically clear and require attention to clear. You may remove the task and re-add it later if there is a condition corrected that improves its chances of executing to completion.
Stalls in the Task Queue
Tasks can be added to the task queue that cannot execute to completion. In this case, the task queue might stall waiting for attention or the appropriate updater to execute. Examples may include the following:
- A task requires the UEFI BIOS to execute it (
Uefi
). In this case the task does not execute until the server is rebooted. - A task requires SUM or SUT to execute it (
RuntimeAgent
). In this case the task does not execute until either SUM or SUT is executed on the server. If neither is installed, the task waits forever. - A task might result in an exception state. In this case, the task will remain in the queue and no further tasks will be executed until the Task Queue is cleared and reset.
- A task may be scheduled to execute during a time range in the past or in the future.
Maintenance Windows
Tasks can be created and Install Sets invoked with either an explicit time range (specifying StartAfter
and Expire
times) or by referring by Id
to a Maintenance Window.
The Maintenance Window collection is pointed to by UpdateService
Oem/Hpe/MaintenanceWindows
:
A special feature of Maintenance Windows is that any task associated with a Maintenance Window may be rescheduled by PATCHing the Maintenance Window instead of modifying multiple tasks.
Creating Maintenance Windows
POST a new object to the Maintenance Window collection:
{
"Name": "unique name of the Maintenance Window.",
"StartAfter": "ISO 8601 Redfish-style time string of earliest execution - null for no start time specified",
"Expire": "ISO 8601 Redfish-style time string after which we will automatically change state to Expired - null for no expire time"
}
Any of these properties may be PATCHed to modify an existing Maintenance Window.
Referring to Maintenance Windows
Each Maintenance Window has an Id
string property. Use this value with the MaintenanceWindow
property when creating a task or invoking an install set.
Removing Maintenance Windows
Maintenance Windows are removed by performing a DELETE operation on the Maintenance Window member.
Maintenance Windows will eventually be outdated with times in the past and should be removed.
Install Sets
Create a new install set resource to create Install Sets. POST a new install set object to the install set collection pointed to by UpdateService
Oem/Hpe/InstallSets
:
Creating Install Sets
POST a new install set object to the install set collection:
{
"Name": "unique name of the install set.",
"IsRecovery": false,
"Sequence": [
{
"Name": "Client supplied friendly name of this task item.",
"UpdatableBy": [
"Uefi",
"RuntimeAgent"
],
"Command": "ApplyUpdate",
"Filename": "Name of the file as it appears in the repository."
}
]
}
Invoking Install Sets
Install Sets are invoked by performing the Invoke
action on the install set member item. The Invoke action has no parameters.
Invoking an install set causes iLO to append the task queue with new tasks, each corresponding to the items in the Sequence array.
POST /redfish/v1/updateservice/installsets/{id}/Actions/HpeComponentInstallSet.Invoke
Content-Type: application/json
{
"ClearTaskQueue": true,
}
Scheduled Install Sets
A client may specify a time window for an Install Set. Time is always relative to iLO’s clock. Two options exist for creating scheduled tasks: explicit time ranges or Maintenance Windows.
Explicit Time Range: Include StartAfter
and Expire
in Invoke
StartAfter
and Expire
are two times that can be included in Invoke
Action. You may specify either or both. Each must be formatted as an ISO 8601 time string.
Each task in the Install Set will be created with this explicit time range. Tasks in the Pending
state will not begin execution until iLO time is after StartAfter
. If for some reason an update does not start and remains in a Pending
state until after the Expire
time, it will never be executed and the State will be Expired. This can happen for instance if a task is to be executed by UEFI and no reboot happens during the time window.
POST /redfish/v1/updateservice/installsets/{id}/Actions/HpeComponentInstallSet.Invoke
Content-Type: application/json
{
"ClearTaskQueue": true,
"StartAfter": "ISO 8601 Redfish-style time string of earliest execution - null for no start time specified",
"Expire": "ISO 8601 Redfish-style time string after which we will automatically change state to Expired - null for no expire time"
}
Install sets and Maintenance Windows
If a client creates a Maintenance Window, this window may be specified (by Id
) in the Install Set Invoke
.
POST /redfish/v1/updateservice/installsets/{id}/Actions/HpeComponentInstallSet.Invoke
Content-Type: application/json
{
"ClearTaskQueue": true,
"MaintenanceWindow": "<maintenance-windows-Id>"
}
Removing Install Sets
Install Sets are removed by performing a DELETE operation on the install set member.
Using Install Sets for Rollback and Baseline Management
iLO does not maintain a specific rollback
architecture. Instead, a client might maintain alternate versions of the same deliverable in the iLO Repository, and maintain multiple (up to 8) install sets in the InstallSets collection.
Firmware Recovery Install Set
SystemRecoveryConfigPriv
One of the install sets on the system might be marked with a property "IsRecovery": true
. If true, the install set is reserved to hold only critical firmware recovery components.
Administrate Recovery Set
iLO user privilege is required to modify or remove this install set. This is called SystemRecoveryConfigPriv
in the REST API’s Account privileges. This privilege enables users to alter or remove this recovery install set.
The recovery install set should only be modified with care and hold a minimal set of firmware updates needed to make the server bootable. These firmware image file must be directly flashable by iLO. The order is important because the install set is the order of update.
Firmware Verification
Firmware Verification, available with the iLO Advanced Premium Security Edition, enables you to run an on-demand verification scan or implement scheduled scans.
To respond to detected issues, choose between logging the results, or logging the results and initiating a repair action that uses a recovery install set.
Depending on the scan results, information is logged in the Active Health System Log and the Integrated Management Log.
The following firmware items are verified:
- iLO 6
- System UEFI BIOS
- System Programmable Logic Device (CPLD)
- Server Platform Services (SPS) Firmware
- Innovation Engine (IE) Firmware
When a firmware verification scan is in progress, you cannot install firmware updates or upload firmware to the iLO Repository.
Configuring Firmware Verification
Available with iLO Advanced Premium Security Edition
Firmware Verification scan options:
- Enable Background Scan (
EnableBackgroundScan
) enables or disables Firmware Verification scanning. When enabled, iLO scans the supported installed firmware for file corruption. - Integrity Failure Action (
OnIntegrityFailure
) determines the action iLO takes when a problem is found during a Firmware Verification scan.- To log the results, patch
LogOnly
. - To log the results and initiate a repair action, patch
LogAndRepairAutomatically
.
- To log the results, patch
If a problem is detected for a supported firmware item, iLO checks for the affected firmware type in a protected install set. By default, this set is the System recovery set. If a firmware image is available, iLO flashes that firmware image to complete the repair.
- Scan Interval (“
ScanEveryDays
”) sets the background scan frequency in days. Valid values are from 1 to 365.
GET /redfish/v1/UpdateService/
{
"Oem": {
"Hpe": {
"FirmwareIntegrity": {
"EnableBackgroundScan": true,
"LastScanResult": "OK",
"LastScanTime": "2017-05-31T19:14:54Z",
"OnIntegrityFailure": "LogAndRepairAutomatically",
"ScanEveryDays": 14
}
}
}
}
Initiating a Firmware Verification Scan
Available with iLO Advanced Premium Security Edition
You may manually start a firmware verification scan by invoking the action StartFirmwareIntegrityCheck
. You must have the iLO Advanced Premium Security Edition license to use this feature.
POST /redfish/v1/UpdateService/Actions/Oem/Hpe/HpeiLOUpdateServiceExt.StartFirmwareIntegrityCheck
Managing BIOS with Redfish
The link to the Bios
resource is defined in Redfish. See UEFI BIOS section for more details.
iLO 6 example Bios link
{
"Bios": {
"@odata.id": "/redfish/v1/Systems/1/Bios"
}
}
BIOS Current/Pending Settings Resources
- All BIOS Attributes name/value pairs that are referenced in the Attribute Registry are moved from the top level of the resource to be grouped under an “Attributes” Redfish property.
- New Actions on BIOS resources.
- ResetBios to reset BIOS configuration to defaults.
- ChangePassword to change BIOS passwords.
Reading BIOS Current Settings
To GET the current BIOS configuration:
curl https://{iLO}/redfish/v1/systems/1/bios/settings/ -i --insecure -u username:password -L
# Make sure the DMTF redfish library is not loaded before loading
# the HPE python-ilorest-library:
# pip uninstall redfish
# pip install python-ilorest-library
import sys
import json
from redfish import RedfishClient
# When running remotely, connect using the iLO address, iLO account name,
# and password to send https requests.
SYSTEM_URL = "https://{BMC}"
LOGIN_ACCOUNT = "username"
LOGIN_PASSWORD = "password"
ca_cert_data = {}
# Create a REST object
REDFISHOBJ = RedfishClient(base_url=SYSTEM_URL, username=LOGIN_ACCOUNT, password=LOGIN_PASSWORD, ca_cert_data=ca_cert_data)
# Login
REDFISHOBJ.login()
# Get the resource you need.
response = REDFISHOBJ.get("/redfish/v1/systems/1/bios/")
print('Response: '+json.dumps(response.dict, indent=4, sort_keys=True))
Response
{
"@Redfish.Settings": {
"@odata.type": "#Settings.v1_0_0.Settings",
"ETag": "5DFD7F66",
"Messages": [
{
"MessageId": "Base.1.0.Success"
}
],
"SettingsObject": {
"@odata.id": "/redfish/v1/systems/1/bios/settings/"
},
"Time": "2001-05-07T20:28:28+00:00"
},
"@odata.context": "/redfish/v1/$metadata#Bios.Bios",
"@odata.etag": "W/\"D230AB047BF85050500CD97692925EA4\"",
"@odata.id": "/redfish/v1/systems/1/bios/",
"@odata.type": "#Bios.v1_0_0.Bios",
"Actions": {
"#Bios.ChangePassword": {
"target": "/redfish/v1/systems/1/bios/Actions/Bios.ChangePasswords/"
},
"#Bios.ResetBios": {
"target": "/redfish/v1/systems/1/bios/Actions/Bios.ResetBios/"
}
},
"AttributeRegistry": "BiosAttributeRegistryU32.v1_1_20",
"Attributes": {
"AcpiHpet": "Enabled",
"AcpiRootBridgePxm": "Enabled",
...
...
"XptPrefetcher": "Enabled",
"iSCSIPolicy": "SoftwareInitiator"
},
"Id": "bios",
"Name": "BIOS Current Settings",
"Oem": {
"Hpe": {
"@odata.type": "#HpeBiosExt.v2_0_0.HpeBiosExt",
"Links": {
"BaseConfigs": {
"@odata.id": "/redfish/v1/systems/1/bios/baseconfigs/"
},
"Boot": {
"@odata.id": "/redfish/v1/systems/1/bios/boot/"
},
"Mappings": {
"@odata.id": "/redfish/v1/systems/1/bios/mappings/"
},
"TlsConfig": {
"@odata.id": "/redfish/v1/systems/1/bios/tlsconfig/"
},
"iScsi": {
"@odata.id": "/redfish/v1/systems/1/bios/iscsi/"
}
},
"SettingsObject": {
"UnmodifiedETag": "W/\"7F8B308F162455555532A6400C9EEBC3\""
}
}
}
}
The iLO RESTful API enables UEFI BIOS configuration. The link to the BIOS configuration is from the computer system object.
Changing Pending Settings and understanding “@Redfish.Settings”
The current configuration object for BIOS is read-only. This object contains a link to a Settings resource that you can perform a PATCH operation on. This is the pending settings
. If you GET the Settings resource, the returned information shows that you can perform PATCH operations. You can change properties and then perform a PATCH patch operation using the Settings URI. Changes to pending settings do not take effect until the server is reset. Before the server is reset, the current and pending settings are independently available. After the server is reset, the pending settings are applied and you can view any errors in the @Redfish.Settings
property on the main object.
There are benefits to handling BIOS settings in this way:
- Enables offline components (for example, BIOS) to process changes to settings in a deferred manner.
- Allows current and pending values to remain available for review until the offline component processes the pending settings.
- Avoids the need for complex job queues.
Updating the BIOS settings example
curl -H "Content-Type: application/json" -X PATCH --data "@data.json" https://{iLO}/redfish/v1/Systems/1/bios/settings/ -u username:password --insecure
Contents of data.json
{“Attributes”:{“AdminName”: “NewName”}}
For a full Redfish example click here: change_bios_setting.py
The minimum required session ID privileges is Configure.
- Iterate through
/redfish/v1/Systems
and choose a member ComputerSystem. Result ={ilo-ip-address}/redfish/v1/Systems/1/BIOS
- Find a link in the
Oem/Hp/links
calledBios
and note theBiosURI
. GET BiosObj
fromBiosURI
and note that it only allowsGET
(this is the current settings).- Find a link in
BiosObj
calledSettings
and note this URI. - Obtain the BIOS settings using the URI from step 4.
GET {ilo-ip-address}/redfish/v1/Systems/1/BIOS/Settings
- Create a new JSON object with the
AdminName
property changed to{"Attributes":{"AdminName":"Joe Smith"}}
. - Update the BIOS settings. You only need to send the updated
AdminName
property in the request body.PATCH {ilo-ip-address}/redfish/v1/Systems/1/BIOS/Settings
- Obtain the BIOS settings to verify you made the change to the AdminName property.
GET {ilo-ip-address}/redfish/v1/Systems/1/BIOS/Settings
When the server is reset, the BIOS settings are validated and adopted.
Settings Result Report
The result of applying new settings is Redfish conformant in iLO 6.
iLO 6 example:
{
"@Redfish.Settings": {
"@odata.type": "#Settings.v1_0_0.Settings",
"ETag": "92EB7D02",
"Messages": [
{
"MessageId": "Base.1.0.PropertyUnknown",
"RelatedProperties": [
"#/Attributes/ProcTurboMode"
]
},
{
"MessageId": "Base.1.0.Success"
}
],
"SettingsObject": {
"@odata.id": "/redfish/v1/Systems/1/Bios/Settings"
},
"Time": "2012-03-07T14:44.30-05:00"
}
}
BIOS Defaults and Passwords
Actions are POST operations to perform a specific request, such as a system reset or a password change. The Bios resource has 2 actions:
Reset Bios Settings
UEFI BIOS Supports a POST Action to reset settings.
iLO 6 Reset BIOS Settings Action
{
"Actions": {
"#Bios.ResetBios": {
"target": "/redfish/v1/Systems/1/Bios/Actions/Bios.ResetBios/"
}
}
}
POST /redfish/v1/Systems/1/Bios/Actions/Bios.ResetBios/
no body
Change BIOS password
UEFI BIOS supports a new POST action to change the BIOS password.
"Actions": {
"#Bios.ChangePassword": {
"target": "/redfish/v1/Systems/1/Bios/Actions/Bios.ChangePassword"
}
}
The body of the action should contain:
{
"PasswordName": "Administrator | User",
"OldPassword" : "OldPasswordText",
"NewPassword" : "NewPasswordText"
}
The target link is where the body of the action should be posted.
Reading BIOS Defaults example
The BIOS current configuration object contains a link to a separate read-only object, BaseConfigs
, which lists the BIOS default settings. To get the BIOS BaseConfigs
resource:
curl https://{iLO}/redfish/v1/systems/1/bios/BaseConfigs/ -i --insecure -u username:password -L
import sys
from redfish import AuthMethod, redfish_logger, redfish_client
# When running remotely, connect using the iLO address, iLO account name,
# and password to send https requests.
iLO_host = "https://16.84.27.67"
login_account = "admin"
login_password = "password"
## Create a REDFISH object
REDFISH_OBJ = redfish_client(base_url=iLO_host,username=login_account,password=login_password,default_prefix="/redfish/v1")
# Login into the server and create a session
REDFISH_OBJ.login(auth="session")
# Do a GET on a given path
response = REDFISH_OBJ.get("/redfish/v1/systems/1/bios/BaseConfigs/", None)
# Print out the response
sys.stdout.write("%s\n" % response)
# Logout of the current session
REDFISH_OBJ.logout()
The results looks something like this:
Response
{
"@odata.context": "/redfish/v1/$metadata#HpeBaseConfigs.HpeBaseConfigs",
"@odata.etag": "W/\"1BAB2532EC201D1D1DFED6F112252823\"",
"@odata.id": "/redfish/v1/systems/1/bios/baseconfigs/",
"@odata.type": "#HpeBaseConfigs.v2_0_0.HpeBaseConfigs",
"BaseConfigs": [
{
"default": {
"AcpiHpet": "Enabled",
"AcpiRootBridgePxm": "Enabled",
"AcpiSlit": "Enabled",
...
...
"XptPrefetcher": "Auto",
"iSCSIPolicy": "SoftwareInitiator"
}
}
],
"Capabilities": {
"BaseConfig": true,
"BaseConfigs": false
},
"Id": "baseconfigs",
"Name": "BIOS Default Settings"
}
Notice that BaseConfigs
contains an array of default sets (or base configuration sets). Each base config set contains a list of BIOS properties and their default values. The default base config set contains the BIOS manufacturing defaults. It is possible for BaseConfigs
to contain other sets, like default.user
for user custom defaults.
BIOS resources and attribute registry overview
The BIOS resources are formatted differently than most other resources. BIOS resources do conform to a schema type as all objects do. However, BIOS settings vary widely across server types and BIOS revisions, so it is extremely difficult to publish a standard schema defining all the possible BIOS setting properties. Furthermore, it is not possible to communicate some of the advanced settings such as inter-setting dependencies, and menu structure in json-schema. Therefore, BIOS uses an Attribute Registry.
BIOS Attribute Access
Redfish moves the system-specific BIOS attributes from the top level of the resource into an Attributes
sub-object:
iLO 6 BIOS Settings Example:
{
"Attributes": {
"AdminEmail": "",
"AdminName": "",
"AdminPhone": ""
}
}
Attribute registry
The BIOS Current Configuration resource has a property called AttributeRegistry
. This property indicates the name and version of a registry file that defines the properties in the BIOS configuration. It also includes information about interdependencies between settings.
Due to their size, BIOS Attribute Registries are compressed JSON resources (gzip), so the returned HTTP headers indicate a content-encoding of gzip
. The REST client will need to decompress the resource. This is done automatically in many web clients (like the Postman plugin).
BIOS attribute registry structure
The BIOS attribute registries contains three top-level arrays:
- Menus: Array containing the BIOS attributes menus and their hierarchy. This can be used (for instance) to build a user interface that resembles the local BIOS Setup, or to group
properties that are related such as
ProcessorOptions
andUsbOptions.
- Attributes: Array containing BIOS attributes and information about the attributes such as type, values, etc.
- Dependencies: Array containing a list of dependencies of BIOS attributes on this server.
This includes inter-setting dependencies that might cause one BIOS setting to change its value or its
ReadOnly
property based on the value of another BIOS setting. - BaseConfigs: Array containing a list of default manufacturing settings of BIOS attributes.
This is equivalent to reading the BaseConfigs resource and parsing the object named
default.
BIOS attributes
Each BIOS attribute in the attribute registry includes:
- Type of each BIOS attribute (enum, string, numeric, or Boolean).
- Possible values for enum type attributes.
- Display strings (localized to the registry language) for the attributes and their possible values.
- Help text and warning text (localized).
- Location and display order information, including menu hierarchy for an attribute. BIOS 25
- Value limits, including maximum, minimum, and step values for numeric attributes, and minimum and maximum character lengths, as well as regular expressions for string attributes.
- And other meta-data.
Changes to BIOS Attribute Enum Values
Attribute names/enum values cannot start with digits, per OData requirements.
iLO 6 example:
{
"AsrTimeoutMinutes": "TimeOut10",
"SerialConsoleBaudRate": "Baud115200",
}
BIOS HPE OEM Resources
All the remaining HPE OEM resources remain similar to iLO 5, except for following:
- Includes the Redfish conformance changes
- Major version change to v2_0_0
The impacted resources are:
HpeBiosMapping
HpeServerBootSettings
HpeBaseConfigs
HpeiSCSISoftwareInitiator
Existing BIOS HPE OEM Resources
The following new HPE BIOS OEM resources are added in iLO 5 that exists in iLO 6:
HpeBiosExt.v2_0_0.HpeBiosExt
- Provider HPE BIOS OEM extensions toBIOS.v1_0_0
resource, specifically in thelinks.Oem
property.
Disabling IPMI Interrupt Support
NOTE: On iLO6 1.10, disabling IPMI Interrupt Support and rebooting the server helps to run the IPMI in-band operation in Windows operating system. See IPMI in-band operation fails to work in Windows OS .
PATCH Payload
PATCH
/redfish/v1/systems/1/bios/oem/hpe/service/Settings
{
"Attributes": {
"KcsIpmiInterrupt": "Disabled"
}
}
Perform system reboot
POST Payload
POST
/redfish/v1/Systems/1/Actions/ComputerSystem.Reset/
{
"ResetType": "GracefulRestart"
}
Enabling and Disabling the KCS interface feature for iLO
IPMI over Keyboard Controller Style (KCS) enables management of the computer system and monitoring of the operations from within the host Operating System (OS).
You can enable/ disable the KCS interface feature for iLO Redfish API using PATCH
. To enable KCS change the value to true
.
PATCH Payload
PATCH
/redfish/v1/Managers/1/NetworkProtocol
{
"Oem": {
"Hpe":{
"KcsEnabled": false
}
}
}
Resetting all BIOS and boot order settings to factory defaults
- Iterate through
/redfish/v1/Systems/
and choose a memberComputerSystem.
Find the BIOS settings resource by following theBios
property link.- BiosSettingsURI =
{ilo-ip-address}/redfish/v1/Systems/1/BIOS/Settings/
- BiosSettingsURI =
- Obtain the BIOS and boot order pending settings.
- GET @
{ilo-ip-address}/redfish/v1/Systems/1/BIOS/Settings/
- GET @
- Create a new JSON object with the
RestoreManufacturingDefaults
property and change the value toYes
. Be sure to include the top level JSONAttributes
property.- JSON = {“Attributes”:{“RestoreManufacturingDefaults”:“Yes”}}
- Make a PATCH request with the new JSON to the
BiosSettingsUri
. You only need to send the updatedRestoreManufacturingDefaults
property in the request body.PATCH {"Attributes":{"RestoreManufacturingDefaults":"Yes"}} @ {ilo-ip-address}/redfish/v1/Systems/1/BIOS/Settings/
Reverting BIOS UEFI settings to default example
curl -H "Content-Type: application/json" -X POST --data "@data.json" https://{iLO}/redfish/v1/Systems/1/bios/settings/ -u username:password --insecure
Contents of data.json
{“Attributes”:{“BaseConfig”: “default”}}
For a full Redfish example click here: bios_revert_default.py
The BIOS Settings resource supports a special feature that allows you to revert BIOS settings to default for the selected resource. This is accomplished by performing the PATCH or PUT operation on a special property in the BIOS settings object: {“BaseConfig”: “default”}. This can be combined with other property sets to first set default values and then set specific settings all in one operation.
NOTE: The BaseConfig
property might not already exist in the BIOS or BIOS Settings resources. To determine if the BIOS resource supports reverting the settings to default, GET
the BIOS BaseConfigs
resource, and view the Capabilities
property.
- Iterate through
/redfish/v1/Systems/
and choose a memberComputerSystem
. Find the BIOS settings resource by following theBios
property link.- BiosSettingsURI =
{ilo-ip-address}/redfish/v1/Systems/1/BIOS/Settings/
- BiosSettingsURI =
- Obtain the BIOS pending settings.
- GET @
{ilo-ip-address}/redfish/v1/Systems/1/BIOS/Settings/
- GET @
- Create a new JSON object with the
BaseConfig
property and change the value todefault
. Be sure to include the top level JSONAttributes
property.- JSON = {“Attributes”:{“BaseConfig”:“default”}}
- Make a PUT request with the new JSON to the
BiosSettingsUri
. You only need to send the updatedBaseConfig
property in the request body.PUT {"Attributes":{"BaseConfig":"default"}} @ {ilo-ip-address}/redfish/v1/Systems/1/BIOS/Settings/
When the sever is reset, the BIOS UEFI settings are reverted to default.
NOTE:
- You might also view the default values for BIOS settings by finding the resource type
HpeBaseConfigs.
{ilo-ip-address}/redfish/v1/Systems/1/BIOS/BaseConfigs
BaseConfig
can be combined with other property values to first reset everything to default and then apply some specific settings in one operation.
Redfish conformant HPE Links
With a Redfish conformant BIOS resource structure, some HPE-specific links are moved into an HPE specific section.
iLO 6 example of HPE-specific links:
{
"Links": {
"Oem": {
"Hpe": {
"@odata.type": "#HpeBiosExt.v2_0.0.HpeBiosExt",
"BaseConfigs": {
"@odata.id": "/redfish/v1/Systems/1/BIOS/BaseConfigs"
},
"Boot": {
"@odata.id": "/redfish/v1/Systems/1/BIOS/Boot"
},
"Mappings": {
"@odata.id": "/redfish/v1/Systems/1/BIOS/Mappings"
},
"iScsi": {
"@odata.id": "/redfish/v1/Systems/1/BIOS/iScsi"
}
}
}
}
}
Enabling BIOS UEFI Secure Boot example
curl -H "Content-Type: application/json" -X PATCH --data "@data.json" https://{iLO}/redfish/v1/Systems/1/SecureBoot/ -u username:password --insecure
Contents of data.json
{“SecureBootEnable”:true}
For a full Redfish example click here: enable_secure_boot.py
The minimum required session ID privileges is Configure.
- Iterate through
/redfish/v1/Systems/
and choose a member ComputerSystem. Find a child resource of typeSecureBoot
that allowsPATCH
operations (there might be more than one, but for this exercise, choose the first one).{ilo-ip-address}/redfish/v1/Systems/1/SecureBoot/
- Obtain the secure boot settings.
GET {ilo-ip-address}/redfish/v1/Systems/1/SecureBoot/
- Create a new JSON object with the
SecureBootEnable
property changed to{"SecureBootEnable":true}.
- Update the secure boot settings. Send the updated
SecureBootEnable
property in the request body.PATCH {ilo-ip-address}/redfish/v1/Systems/1/SecureBoot/
When the sever is reset, the boot settings are validated and adopted.
iSCSI Software Initiator Configuration
The iSCSI Software Initiator allows you to configure an iSCSI target device to be used as a boot source. The BIOS current configuration object contains a link to a separate resource of type HpeiSCSISoftwareInitiator.
The BIOS current configuration resource and the iSCSI Software Initiator current configuration resources are read-only. To change iSCSI settings, you need to follow another link to the Settings
resource, which allows PUT
and PATCH
operations.
The iSCSI target configurations are represented in an iSCSISources
property, that is an array of objects, each containing the settings for a single target. The size of the array represents the total number of iSCSI boot sources that can be configured at the same time. Many mutable properties exist, including iSCSIAttemptInstance,
which can be set to a unique integer in the range [1, N], where N is the boot sources array size. By default, this instance number is 0 for all objects, indicating that the object should be ignored when configuring iSCSI.
Each object also contains two read-only properties—StructuredBootString
and UEFIDevicePath
, which are only populated after the target has been successfully configured as a boot source. More information about each property is available in the corresponding schema. The iSCSI initiator name is represented by the iSCSIInitiatorName
property.
An additional read-only property, iSCSINicSources,
is only shown in the iSCSI current configuration resource. This property is an array of strings representing the possible NIC instances that can be used as targets for iSCSI boot configuration. To confirm which NIC device each string corresponds to, it is recommended to cross-reference two other resources:
- A resource of type
HpeBiosMapping
can be found through aMappings
link in the BIOS current configurations resource. Within itsBiosPciSettingsMappings
property is an array of mappings between BIOS-specific device strings (such as theNIC
source string) and aCorrelatableID
string that can be used to refer to the same device in non-BIOS contexts. - A collection of
HpeServerPciDevices
may be found through a PCIDevices link in theComputerSystem
resource. The specific PCI device corresponding to the NIC instance can be found by searching for theCorrelatableID
that will usually match aUEFIDevicePath.
Once theHpeServerPciDevice
resource is found, you have access to all the human-readable properties useful for describing a NIC source.
Changing the iSCSISources
and iSCSIInitiatorName
settings can be done through PATCH
operations, very similar to how HpeBios
settings are changed. However, whereas all BIOS settings are located in a single flat object, iSCSI settings are nested into arrays and sub-objects.
When doing a PATCH
operation, use empty objects ({}
) in place of those boot source objects that you do not want to alter.
The following example covers a situation where you have configured two iSCSI boot sources, and you would like to edit some existing settings, and add a third source.
- Iterate through
/redfish/v1/Systems
and choose a memberComputerSystem.
Find a child resource of typeHpiSCSISoftwareInitiator
that allows PATCH operations.{ilo-address}/redfish/v1/Systems/1/BIOS/iSCSI/Settings/
- Inspect the existing
iSCSIBootSources
array. You need to inspect theiSCSIBootAttemptInstance
property of each object to find the boot sources you prefer to change. - Create a new JSON object with the iSCSIBootSources property.
- Use an empty object in the position of instance 1 to indicate that it should not be modified. Use an object in the position of instance 2 containing the properties that should be modified—all omitted properties will remain unmodified.
- To add a new boot source, find any position of instance 0 and replace it with an object containing all the new settings, and most importantly, a new unique value of iSCSIBootAttemptInstance.
- Change the iSCSI software initiator settings.
PATCH {ilo-address}/redfish/v1/Systems/1/BIOS/iSCSI/Settings/
Example iSCSI Software Initiator configuration
Existing example resource:
{
"iSCSISources": [
{
"iSCSIAttemptInstance": 1,
...
},
{
"iSCSIAttemptInstance": 2,
...
},
{
"iSCSIAttemptInstance": 0,
...
},
{
"iSCSIAttemptInstance": 0,
...
}
],
...
}
{
"iSCSISources": [
{},
{
"iSCSIConnectRetry": 2
},
{
"iSCSIAttemptInstance": 3,
"iSCSIAttemptName": "Name",
"iSCSINicSource": "NicBootX"
...
},
{}
]
}
HTTPS Boot TLS Configuration
TLS Certificates Resource has three resources within the RESTful API tree:
- Current Settings Resource (read-only) : redfish/v1/systems/1/bios/tlsconfig/
- Contains current TLS certificates resource configuration data present in the system
- Pending Settings Resource (read/write) : redfish/v1/systems/1/bios/tlsconfig/settings/
- Writable resource used to configure TLS certificates settings
- Modifiable properties:
- "Ciphers"
- Set the desired supported ciphers
- "HostnameCheck"
- Enable/Disable host name checking
- "ProtocolVersion"
- Set the desired protocol version
- "VerifyMode"
- Set the verification method (PEER/NONE)
- "NewCertificates"
- An array of the certificates to be installed
- "DeleteCertificates"
- An array of the fingerprints of the certificates to be deleted
- Read Only properties that gets modified internally:
- "Certificates"
- An array of all the installed certificates
- "TlsCaCertificateCount"
- The number of the installed certificates
- TLS Default Settings Resource (read-only) : redfish/v1/systems/1/bios/tlsconfig/baseconfigs/ Holds the default values of the resource
Installing Certificates
The certificates are X509 keys. In PEM format, the certificates are encoded in a series of strings with new line characters between them:
This an example of a certificate in a PEM format:
—–BEGIN CERTIFICATE—– MIIEHTCCAwWgAwIBAgIQe8LmWgF5edKw01/avJg69DANBgkqhkiG9w0BAQsFADCB kTELMAkGA1UEBhMCVVMxKzApBgNVBAoTIkhld2xldHQgUGFja2FyZCBFbnRlcnBy aXNlIENvbXBhbnkxIDAeBgNVBAsTF0luZnJhc3RydWN0dXJlIFNlcnZpY2VzMTMw
It should be modified to add the new line characters:
—–BEGIN CERTIFICATE—–\r\nMIIGxDCCBaygAwIBAgIQUkL9757013wOQ2heZMCLizANBgkqhkiG9w0BAQsFADCB\r\nkTELMAkGA1UEBhMCVVMxKzApBgNVBAo TIkhld2xldHQgUGFja2FyZCBFbnRlcnBy\r\naXNlIENvbXBhbnkxIDAeBgNVBAsTF0luZnJhc3RydWN0dXJlIFNlcnZpY2VzMTMw\r\n
Notice the “\r\n” added at the beginning of the certificate and at end of each line in the certificate body. Finally, the certificate needs to be PUT (only a PUT would work) through the API (Postman,..), as many as needed to be installed. See the examples in the right pane for more information:
PUT /redfish/v1/Systems/{item}/bios/tlsconfig/settings/
{
"NewCertificates": [
{
"X509Certificate":"-----BEGIN CERTIFICATE-----\r\nMIIGxDCCBaygAwIBAgIQUkL9757013wOQ2heZMCLizANBg......"
}
]
}
Once installed, it will look like this after rebooting:
{
"@odata.context": "/redfish/v1/$metadata#HpeTlsConfig.HpeTlsConfig",
"@odata.etag": "W/\"DAE5B73CD430CFCFCF7E180C05FE6C9E\"",
"@odata.id": "/redfish/v1/systems/1/bios/tlsconfig/settings/",
"@odata.type": "#HpeTlsConfig.v1_0_0.HpeTlsConfig",
"Certificates": [
{
"FingerPrint": "54:8C:8B:45:55:30:47:8D:43:8D:44:BF:33:E0:C5:A5:44:1E:E9:5E:B2:0A:AC:A6:CA:59:B6:D9:7B:FC:83:A9",
"Issuer": "C=US, O=Whatever, OU=Infrastructure Services, CN=Whatever Private Root CA",
"SerialNumber": "5242FDEF9EF4D77CE43685E64C08B8B",
"Subject": "O=Whatever, CN=John Smith, OU=XXX-WEB-H, OU=Computer Name - Smith.John, OU=Employment Status - Employees, OU=SmartCard, emailAddress=John.Smith@whatever.com",
"ValidNotAfter": "07/11/2017 23:59",
"ValidNotBefore": "07/11/2016 00:00"
}
],
"Ciphers": "AES128-SHA:AES256-SHA:AES128-SHA256:AES256-SHA256:AES128-GCM-SHA256:AES256-GCM-SHA384",
"DeleteCertificates": [],
"HostnameCheck": "Enabled",
"Id": "settings",
"Name": "TLS Pending Settings",
"NewCertificates": [],
"ProtocolVersion": "AUTO",
"TlsCaCertificateCount": 1,
"VerifyMode": "NONE"
}
Deleting Certificates
When a certificate is installed, a new field is created with the Fingerprint of that certificate (SHA256). To remove a certificate, PUT the fingerprint to remove
PUT /redfish/v1/Systems/1/bios/tlsconfig/settings/
{
"DeleteCertificates": [
{
"FingerPrint": "54:8C:8B:45:55:30:47:8D:43:8D:44:BF:33:E0:C5:A5:44:1E:E9:5E:B2:0A:AC:A6:CA:59:B6:D9:7B:FC:83:A9"
}
]
}
You can delete more than one certificate at a time.
Resetting the resource to its default settings
See the example in the right pane for more information.
PUT /redfish/v1/Systems/1/bios/tlsconfig/settings/
{
"BaseConfig": "Default"
}
The default resource would look like:
{
"@odata.context": "/redfish/v1/$metadata#HpeTlsConfig.HpeTlsConfig",
"@odata.etag": "W/\"F5B8B30487AB151515845B0C2CC520E0\"",
"@odata.id": "/redfish/v1/systems/1/bios/tlsconfig/settings/",
"@odata.type": "#HpeTlsConfig.v1_0_0.HpeTlsConfig",
"Certificates": [],
"Ciphers": "AES128-SHA:AES256-SHA:AES128-SHA256:AES256-SHA256:AES128-GCM-SHA256:AES256-GCM-SHA384",
"DeleteCertificates": [],
"HostnameCheck": "Disabled",
"Id": "settings",
"Name": "TLS Current Settings",
"NewCertificates": [],
"ProtocolVersion": "AUTO",
"TlsCaCertificateCount": 0,
"VerifyMode": "PEER"
}
Examples of other changes
- Modifying Ciphers
PATCH /redfish/v1/Systems/1/bios/tlsconfig/settings/
{
"Ciphers": "AES128-SHA:AES256-SHA"
}
- Modifying VerifyMode PEER or NONE.
PATCH /redfish/v1/Systems/1/bios/tlsconfig/settings/
{
"VerifyMode": "PEER"
}
- Modifying HostnameCheck Can not be changed if VerifyMode is set to NONE.
PATCH /redfish/v1/Systems/1/bios/tlsconfig/settings/
{
"HostnameCheck": "Enabled"
}
- Modifying ProtocolVersion “AUTO”, “1.0”, “1.1” or “1.2”.
PATCH /redfish/v1/Systems/1/bios/tlsconfig/settings/
{
"ProtocolVersion": "1.1"
}
SSL certificates
SSL protocol is a standard for encrypting data so that it cannot be viewed or modified while in transit on the network. This protocol uses a key to encrypt and decrypt the data. Generally, the longer the key, the better the encryption.
A certificate is a small data file that connects an SSL key to a server. The certificate contains the server name and the server public key. Only the server has the corresponding private key, and this is how it is authenticated.
A certificate must be signed to be valid. If it is signed by a Certificate Authority (CA), and that CA is trusted, all certificates signed by the CA are also trusted. A self-signed certificate is one in which the owner of the certificate acts as its own CA. By default, iLO creates a self-signed certificate for use in SSL connections. This certificate enables iLO to work without additional configuration steps.
IMPORTANT: Using a self-signed certificate is less secure than importing a trusted certificate. Hewlett Packard Enterprise recommends importing a trusted certificate to protect the security of the iLO processor.
Manually obtaining and importing an SSL certificate
iLO allows you to create a Certificate Signing Request that you can send to a Certificate Authority to obtain a trusted SSL certificate to import into iLO.
An SSL certificate works only with the keys generated with its corresponding CSR. If iLO is reset to the factory default settings, or another CSR is generated before the certificate that corresponds to the previous CSR is imported, the certificate does not work. In that case, a new CSR must be generated and used to obtain a new certificate from a CA.
Obtain a trusted certificate from a Certificate Authority (CA)
Prerequisites:
- Configure iLO Settings privilege.
Enter the following details when you create a CSR: * City or Locality (L)—The city or locality where the company or organization that owns this iLO subsystem is located. * Common Name (CN)—The FQDN of this iLO subsystem. * Country ©—The two-character country code that identifies the country where the company or organization that owns this iLO subsystem is located. Enter the two-letter abbreviation in capital letters. * Organization Name (O)—The name of the company or organization that owns this iLO subsystem. * Organizational Unit (OU)—(Optional) The unit within the company or organization that owns this iLO subsystem. * State (ST)—The state where the company or organization that owns this iLO subsystem is located.
POST
/redfish/v1/managers/{item}/securityservice/httpscert/HpeHttpsCert.GenerateCSR
{
"City": "<City>",
"CommonName": "<CommonName>",
"Country": "<Country>",
"IncludeIP": <true or false>,
"OrgName": "<OrgName>",
"OrgUnit": "<OrgUnit>",
"State": "<State>"
}
Importing a trusted certificate
Prerequisites:
- Configure iLO Settings privilege.
POST
/redfish/v1/managers/{item}/securityservice/httpscert/HpeHttpsCert.ImportCertificate
{
"Certificate": "<text>"
}
Automatic Certificate Enrollment
From iLO5 2.60 onwards, iLO supports obtaining and renewing SSL certificate automatically using the Simple Certificate Enrollment Protocol (SCEP). Currently, iLO supports these features on the Microsoft Network Device Enrollment Service (NDES).
By default the feature is disabled. To enable automatic certificate enrollment for iLO, you must first configure the following services on the certificate enrollment server: - Configure the Certificate Authority (CA). CA is the server that runs the Certificate Services and issues certificates. - Configure NDES. NDES is the Certificate Enrollment Server.
NOTE: This feature is not supported when iLO is in CNSA security state.
Enabling Automatic Certificate Enrollment
Prerequisites:
- iLO5 2.60 or later
- Configure iLO Settings privilege
- URL of the certificate enrollment server
- Challenge password
- CA certificate of the certificate enrollment server must be imported. (See Obtain a trusted certificate from a Certificate Authority (CA)).
- Configure CSR
- A license that supports this feature is installed. (For information about the available license types and the features they support, see the licensing documentation.
NOTE: If Enrollment Service is enabled, removal and manual import of certificate is not allowed.
To enable Automatic Certificate Enrollment, perform PATCH
on /redfish/v1/Managers/1/SecurityService/AutomaticCertificateEnrollment
PATCH
/redfish/v1/Managers/1/SecurityService/AutomaticCertificateEnrollment
PATCH Payload:
{
"AutomaticCertificateEnrollmentSettings" : {
"ServiceEnabled" : true,
"ServerUrl" : "<CertificateServerURL>",
"ChallengePassword" : "<ChallengePassword>"
}
}
Updating certificate enrollment settings
Prerequisites:
- Configure iLO Settings privilege
NOTE: Updating the settings does not initiate certificate enrollment. To start the enrollment, first disable the service and enable it again.
To view the automatic certificate enrollment settings, perform GET
on
GET
/redfish/v1/Managers/1/SecurityService/AutomaticCertificateEnrollment
{
"@odata.context": "/redfish/v1/$metadata#HpeAutomaticCertEnrollment.HpeAutomaticCertEnrollment",
"@odata.etag": "W/\"<ETAG>\"",
"@odata.id": "/redfish/v1/Managers/1/SecurityService/AutomaticCertificateEnrollment/",
"@odata.type": "#HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment",
"Id": "AutomaticCertificateEnrollment",
"Actions": {
"#HpeAutomaticCertEnrollment.ImportCACertificate": {
"Certificate@Redfish.AllowableValues": [
"Certificate"
],
"target": "/redfish/v1/Managers/1/SecurityService/AutomaticCertificateEnrollment/Actions/HpeAutomaticCertEnrollment.ImportCACertificate/"
}
},
"AutomaticCertificateEnrollmentSettings": {
"CACertificateName": "Unavailable",
"CertificateEnrollmentStatus": "Disabled",
"ChallengePassword": null,
"ServerUrl": "",
"ServiceEnabled": false
},
"HttpsCertCSRSubjectValue": {
"City": "<City>",
"CommonName": "<CommonName>",
"Country": "<Country>",
"IncludeIP": false,
"OrgName": "<OrgName>",
"OrgUnit": "<OrgUnit>",
"State": "<State>"
}
}
Modifying Webserver CSR subject contents
To modify the webserver CSR subject contents, perform PATCH
on /redfish/v1/Managers/1/SecurityService/AutomaticCertificateEnrollment
PATCH
/redfish/v1/Managers/1/SecurityService/AutomaticCertificateEnrollment
PATCH Payload:
{
"HttpsCertCSRSubjectValue": {
"City": "<City>",
"CommonName": "<CommonName>",
"Country": "<Country>",
"IncludeIP": false,
"OrgName": "<OrgName>",
"OrgUnit": "<OrgUnit>",
"State": "<State>"
}
}
Renewing automatically managed SSL certificate
When the certificate enrollment service is enabled and the certificate is about to expire (that is 30 days from the expiry date), iLO initiates certificate renewal automatically. As soon as iLO initiates certificate renewal, the certificate enrollment status will change to InProgress
.
Certificate enrollment status will change to Success
when the renewal is successful. For information on renewal status, see the Security Logs. You must reset iLO manually after successful renewal. The newly trusted certificate will be in use only after iLO reset.
Certificate enrollment status will change to Failed
if the renewal fails. For more information on cause of failure and
recommended actions, see the Security Logs.
Viewing webserver certificate
Webserver certificate whether self-signed, manually imported or issued automatically can be viewed by performing GET
on redfish/v1/managers/1/securityservice/httpscert/
GET
redfish/v1/managers/1/securityservice/httpscert/
{
"@odata.context": "/redfish/v1/$metadata#HpeHttpsCert.HpeHttpsCert",
"@odata.etag": "W/\"<ETAG>\"",
"@odata.id": "/redfish/v1/Managers/1/SecurityService/HttpsCert/",
"@odata.type": "#HpeHttpsCert.v2_0_0.HpeHttpsCert",
"Id": "HttpsCert",
"Actions": {
"#HpeHttpsCert.GenerateCSR": {
"target": "/redfish/v1/Managers/1/SecurityService/HttpsCert/Actions/HpeHttpsCert.GenerateCSR/"
},
"#HpeHttpsCert.ImportCertificate": {
"target": "/redfish/v1/Managers/1/SecurityService/HttpsCert/Actions/HpeHttpsCert.ImportCertificate/"
}
},
"CertificateSigningRequest": null,
"X509CertificateInformation": {
"Issuer": "CN = <CommonName>, O = <OrgName>, OU = <OrgUnit>, L = <Region>, ST = <State>, C = <Country>",
"SerialNumber": "<SerialNumber>",
"Subject": "CN = <CommonName>, O = <OrgName>, OU = <OrgUnit>, L = <Region>, ST = <State>, C = <Country>",
"ValidNotAfter": "2037-05-26T10:07:53Z",
"ValidNotBefore": "2022-05-27T10:07:53Z"
}
}
Disabling enrollment service
Disabling enrollment service does not remove the certificate generated using the service. To remove the certificate, see Removing an SSL certificate.
When the service is disabled, iLO does not initiate renewal of the certificate automatically.
Prerequisites:
- Configure iLO Settings privilege
To disable Automatic Certificate Enrollment, perform PATCH
on /redfish/v1/Managers/1/SecurityService/AutomaticCertificateEnrollment
PATCH
/redfish/v1/Managers/1/SecurityService/AutomaticCertificateEnrollment
PATCH Payload:
{
"AutomaticCertificateEnrollmentSettings" : {
"ServiceEnabled" : false
}
}
Removing an SSL certificate
Use this feature to remove an SSL certificate and regenerate the iLO self-signed certificate.
NOTE: If Certificate Enrollment Service is enabled, removal and manual import of certificate is not allowed.
You might want to remove a certificate for the following reasons: - The certificate expired. - The certificate contains invalid information. - There are security concerns related to the certificate. - An experienced support organization recommended that you remove the certificate.
Prerequisites:
- Configure iLO Settings privilege
DELETE
/redfish/v1/managers/{item}/securityservice/httpscert/
Security Service
The HpeSecurityService
resource type contains security links and properties mentioned in the Resource definition section of this document. This section provides technical detail concerning several server management identities, including the Server Identity (DevID).
DevID is a standard (based on IEEE 802.1AR) way to uniquely identify a server across networks. DevID is uniquely bound to a server that enables a server to prove its identity in various industry standards and protocols that authenticate, provision, and authorize communicating devices. iLO supports factory provisioned server identity (iLO IDevID) and user defined server identity (iLO LDevID). iLO also stores the system certificates (System IDevID and System IAK).
Following are the different server management identities described in this section:
iLO IDevID
iLO can be provisioned with server identity in the factory. This factory provisioned server identity is called iLO IDevID. HPE servers can be securely on boarded into a customer network using the IDevID for 802.1X authentication. iLO IDevID has life time validity and is immutable.
To instruct the HPE factory to provision a server with an IDevID, include either SKU P41905-B21 (if you do not have a TPM2.0 module) or P42104-B21 (if you have a TPM2.0 module) in your order.
iLO does not allow you to update or delete IDevID since it is immutable.
You can view the iLO IDevID certificate using the RESTful API GET command toward /redfish/v1/Managers/{@managerId}/SecurityService/iLOIDevID/Certificates/{@certId}
iLO LDevID
IDevID can be supplemented by a user defined server identity, called iLO LDevID. iLO LDevID is unique in the administrative domain, in which the server is used. HPE servers can be securely on boarded into a customer network using the LDevID for 802.1X authentication. iLO LDevID can be used on servers that do not have iLO IDevID. LDevID helps in facilitating the enrollment (authentication and authorization of credentials) by local network administrators. iLO allows to import, view, and delete LDevID outside the factory.
Importing an LDevID certificate
NOTE: LDevID certificate import requires the system in the FIPS security state. You can retrieve this state with a GET request toward the HpeSecurityService
URI.
Follow these steps in sequence to import an LDevID certificate:
- Generate a Certificate Signing Request (CSR) for LDevID. iLO allows creation of a CSR in PEM format for LDevID using the RESTful API POST command toward
/redfish/v1/CertificateService/Actions/CertificateService.GenerateCSR
with a body containing the location where the signed certificate will have to be posted. See example in right pane.
A successful response body contains the CSR as well as a link to the destination of the signed certificate in the CertificateCollection
object.
iLO LDevID CSR generation: POST /redfish/v1/CertificateService/Actions/CertificateService.GenerateCSR
{
"CertificateCollection": {
"@odata.id": "/redfish/v1/Managers/1/SecurityService/iLOLDevID/Certificates/"
}
}
Send this CSR to your favorite Certificate Authority to obtain a signed certificate.
Import the signed LDevID certificate into iLO. iLO allows import of LDevID certificate in PEM format using the RESTful API POST command toward
/redfish/v1/Managers/{@managerId}/SecurityService/iLOLDevID/Certificates/
with a body containing theCertificateType
andCertificateString
properties.
NOTE: Replace non ASCII characters like CRLF or CR with literally “\n” in the CertificateString
property.
Import signed LDevID certificate: POST /redfish/v1/Managers/{@managerId}/SecurityService/iLOLDevID/Certificates/
{
"CertificateType": "PEM",
"CertificateString": "-----BEGIN CERTIFICATE-----\n<Contents of the trusted certificate>\n-----END CERTIFICATE-----\n"
}
Before importing, iLO validates the input certificate with the following parameters:
- The public key in the certificate matches the one generated with its corresponding CSR.
- The signing and hashing algorithms used in the certificate are FIPS compliant.
NOTE: iLO supports import of LDevID certificates up to 16 KB size.
Viewing the imported LDevID certificate
To view the imported LDevID certificate, use the following RESTful API GET command toward /redfish/v1/Managers/{@managerId}/SecurityService/iLOLDevID/Certificates/{@certId}
Deleting the imported LDevID certificate
To delete the imported LDevID certificate, use the following RESTful API DELETE command toward /redfish/v1/Managers/{@managerId}/SecurityService/iLOLDevID/Certificates/{@certId}
Updating an LDevID certificate
You cannot update a LDevID certificate. To replace a certificate, you must delete the existing LDevID certificate and generate a new certificate. See Importing an LDevID certificate.
NOTE: In case LDevID certificate is lost due to secure erase, you can restore it using the Backup and Restore feature or replace it.
System IDevID certificate
iLO can be provisioned with the server host identity, available for use by the operating system. This factory provisioned system identity is called System IDevID, whose corresponding private key is stored in TPM. System IDevID follows the TCG proposal for TPM2.0 implementation of an IDevID. You have to order a specific server SKU (P42104-B21) for obtaining System IDevID.
iLO does not allow you to update or delete the certificate.
You can only view the certificate using the RESTful API GET command toward /redfish/v1/Managers/{@managerId}/SecurityService/SystemIDevID/Certificates/{@certId}
System IAK certificate
iLO can be provisioned with the System Initial Attestation Key (IAK) certificate in the factory. This is similar to System IDevID but used for TPM-based attestation. The corresponding private key is stored in TPM. System IAK follows the TCG proposal for TPM2.0 implementation of an IDevID. You have to order a specific server SKU (P42104-B21) for obtaining System IAK certificate.
iLO does not allow you to update or delete the certificate.
You can only view the certificate using the RESTful API GET command toward /redfish/v1/Managers/{@managerId}/SecurityService/SystemIAK/Certificates/{@certId}
NOTE: iLO IDevID, iLO LDevID, System IDevID, and System IAK are preserved across iLO security state transitions, reset to factory defaults.
Platform certificate
iLO can be provisioned with the platform certificate which is an attribute certificate that functions as a signed manifest for the hardware chassis or configuration used to detect supply chain tampering. This certificate is TCG compliant. You have to order a specific server SKU (P42104-B21) for obtaining Platform certificate.
iLO does not allow you to update or delete the platform certificate.
You can only view the certificate using the RESTful API GET command toward /redfish/v1/Managers/{@managerId}/SecurityService/PlatformCert/Certificates/{@certId}
Granularity to enable/disable specific TLS versions
The HpeSecurityService
resource type includes a property called TLSVersion
.
This section details the TLSversion
property which displays the status (Enabled
/ Disabled
) of different TLS versions supported and how they can be modified in different security states.
HPE iLO Standard, that comes with every HPE ProLiant Gen11 or later server, gives customers the ability to configure servers in one of three security states (Production, High Security, and FIPS). With an iLO Advanced license, customers have a fourth security state available to them that needs the highest-level encryption capabilities of CNSA.
iLO features the following security states:
- Production
- High Security
- FIPS (Federal Information Processing Standards)
- CNSA (Commercial National Security Algorithm)
NOTE: * TLS versions 1.0 and 1.1 can be enabled or disabled only in Production mode but they are disabled in higher security modes such as High Security, FIPS, and CNSA. * Tools that do not support TLS 1.2 will not be able to connect to iLO when TLS 1.0 and 1.1 are disabled.
For more information on iLO security states, see the iLO encryption settings
of the HPE iLO 6 User Guide.
Viewing status of TLS versions enabled/disabled
To view the enabled/disabled status of TLS versions, perform GET
on /redfish/v1/Managers/1/SecurityService/
GET
/redfish/v1/Managers/1/SecurityService/
{
...
"TLSVersion": {
"TLS1_0": "Disabled",
"TLS1_1": "Enabled",
"TLS1_2": "Enabled"
}
...
}
NOTE: In iLO 6 v1.05, iLO responds with the status of TLSVersion
property as "TLS1_0": "Disabled"
, "TLS1_1": "Enabled"
, and "TLS1_2": "Enabled"
for GET on /redfish/v1/Managers/1/SecurityService/
.
Modifying the enable/disable status of specific TLS versions
In iLO6 1.05 and iLO6 1.10, the TLSVersion properties are not PATCHable through Redfish. The workaround is to update them through iLO GUI, see “Enabling the Production security state” of the iLO 6 User Guide
NOTE:
- TLS1_0 and TLS1_1 can be enabled only in Production mode. In High Security Mode, they are disabled and only TLS1_2 is enabled.
- Performing an update on TLS versions using the enum values
Enabled
andDisabled
results in the API returningiLO.2.15.PropertyValueBadParam
.
iLO automatically resets after enabling or disabling TLS versions.
Enabling/disabling the TLS versions triggers an event and creates an alert for that event. The message arguments include TLS version being modified, its Status, and the user who requested for the change for the alert.
Updating TLS versions creates an entry in the Security Log
. See Security Logs
Examples of entries (Description) in the Security Log
after performing updating on TLS versions:
TLS Version 1.0 is Disabled by: username
TLS Version 1.0 is Enabled by: username
TLS Version 1.1 is Disabled by: username
TLS Version 1.1 is Enabled by: username
Managing the iLO Redfish Host Interface (“Virtual NIC”)
iLO 6 adds a virtual network interface to access iLO’s HTTPS resources (including the Redfish API and the Web GUI) to the host.
When accessing iLO 6 through the virtual network interface, authentication is enforced.
Enabling the Virtual NIC
The Virtual NIC (also known as the Redfish Host API) is disabled by default but may be enabled either though the Web GUI or by a Redfish operation. An iLO reset is required for this change to take effect.
PATCH /redfish/v1/Managers/{managerId}/
{
"Oem": {
"Hpe": {
"VirtualNICEnabled": true
}
}
}
Using the Virtual NIC
When enabled, software running on the server operating system may access the iLO 6 Web GUI or Redfish API using IP address 16.1.15.1
. Normal authentication is required.
NOTE: The Virtual NIC does NOT act as a passthrough to traffic on the iLO 6 network connection. It is a separate network connection into iLO’s resources.
Disabling the Virtual NIC
The Virtual NIC may be disabled either though the Web GUI or by a Redfish operation. An iLO reset is required for this change to take effect.
PATCH /redfish/v1/Managers/{managerId}/
{
"Oem": {
"Hpe": {
"VirtualNICEnabled": false
}
}
}
Secure Erase
The secure erase process resets iLO and deletes all licenses stored there, resets BIOS settings, and deletes all AHS and warranty data stored on the system. The secure erase process also erases supported non-volatile storage data and deletes any deployment settings profiles. iLO reboots multiple times after the process is initiated.
NOTE: Securely erasing the server can take up to a day to complete.
Secure erase erases supported non-volatile storage data and returns the server to the manufacturing default state. The feature complies with specification NIST SP 800-88 Revision 1, Guidelines for Media Sanitization. For more information about NIST SP 800-88, see https://nvlpubs.nist.gov/nistpubs/specialpublications/nist.sp.800-88r1.pdf. Section 2.5 of the specification describes the level of sanitization. The appendix recommends minimum sanitization levels for media. Secure erase implements the NIST SP 800-88 Revision 1 Sanitization Recommendations for Purging user data and returns the server and supported components to the default state. This feature automates many of the tasks you follow in the Statement of Volatility document for a server. To view what was erased successfully, see View secure erase report. The process can take up to a day to fully erase and reset all user data. When you activate secure erase, iLO 6 does not allow firmware update or reset operations. DO NOT perform any iLO 6 configuration changes until this process is completed.
Secure erase access methods
You can initiate the secure erase process from the following products:
- Intelligent Provisioning 3.30 or later
- The iLO RESTful API
Prerequisites
- User account must have all iLO 6 permissions, including
SystemRecoveryConfigPriv
. - iLO Advanced license.
- Set the iLO security setting on the system maintenance switch to the OFF position.
- Disconnect any FCoE, iSCSI, external SAS, and Fibre Channel storage before using secure erase.
- Disable Server Configuration Lock. For instructions, see the UEFI System Utilities User Guide.
- Disable Smart Storage Encryption. For instructions, see the
Clearing the encryption configuration
section in the HPE Smart Array SR Secure Encryption Installation and User Guide. - For c-Class and Synergy users: Remove HPE OneView or Virtual Connect profiles assigned to the system.
Process flow
- User initiates secure erase.
- Upon reboot, BIOS erases configuration, system time, TPM configuration and user data (drives and persistent memory). The system powers off after completion.
- iLO 6 then erases key NVRAM and NAND data, and then automatically resets.
Initiating secure erase through Redfish
To initiate secure erase, perform a POST
on /redfish/v1/Systems/<index>/Actions/Oem/Hpe/HpeComputerSystemExt.SecureSystemErase/
.
The payload for this POST includes two properties:
Property | Type | Description |
---|---|---|
SystemRomAndiLOErase | Boolean | Reset the system BIOS settings and iLO to manufacturing defaults. It also erases the Active Health System (AHS) user data in the NAND. |
UserDataErase | Boolean | Erase all the user data on the system including TPMs, persistent memory devices, storage controller configurations, RAID settings, and data from the hard drives attached to the system. USB and other removable media will be excluded. |
NOTE: The POST operation payload requires both the SystemRomAndiLOErase
and UserDataErase
parameters to be set to true
to initiate the secure erase process.
NOTE: Once you initiate this process, it cannot be undone.
POST /redfish/v1/Systems/1/Actions/Oem/Hpe/HpeComputerSystemExt.SecureSystemErase/
{
"SystemROMAndiLOErase" : true,
"UserDataErase": true
}
This returns a response indicating that a server system reset is required.
returns
{
"error": {
"code": "iLO.0.10.ExtendedInfo",
"message": "See @Message.ExtendedInfo for more information.",
"@Message.ExtendedInfo": [
{
"MessageId": "iLO.2.7.SystemResetRequired"
}
],
}
}
The client must then initiate a server reset using the Reset action in the ComputerSystem resource.
POST
/redfish/v1/Systems/{id}/Actions/ComputerSystem.Reset
{
"ResetType": "ForceRestart"
}
At this point the UEFI BIOS will begin erasing configuration information.
Monitor status of secure erase
Once the secure erase is initiated, perform GET
on /redfish/v1/Systems/1/
. This resource includes an object Oem.Hpe
which contains the status value properties for the secure erase previously initiated. This includes the following properties:
Property | Type | Description |
---|---|---|
UserDataEraseStatus | Status (Enum) |
Reports the overall user data erase status |
UserDataEraseComponentStatus.{ComponentName} | Status (Enum) |
Indicates the erase status of the individual components |
ElapsedEraseTimeInMinutes | Integer | Reports the time elapsed since the erase started |
EstimatedEraseTimeInMinutes | Integer | Reports the approximate time (in minutes) for the overall erase process |
The Status
enum takes the following values - Idle
, Initiated
, InProgress
, CompletedWithSuccess
, CompletedWithErrors
, Failed
.
View secure erase report
The client must then initiate a server reset using the Reset action in the ComputerSystem resource.
To view the secure erase report for each of the individual drives or disks installed, perform GET
on /redfish/v1/systems/1/Oem/Hpe/EraseReport/{reportId}
.
> curl https://{iLO}/redfish/v1/sytems/1/Oem/Hpe/EraseReport/2 -i --insecure -L
{
"ResetType" : "ForceRestart",
"DeviceType" : "NVMeDrive",
"DeviceIdentifier" : "NVMe M.2 Drive Slot 1 Bay 1",
"SerialNumber" : "<serialNumber>",
"EraseStatus" : "CompletedWithSuccess",
"EraseType" : "PURGE",
"StartTime" : "2019-05-30T08:40:13Z",
"EndTime" : "2019-05-30T08:40:13Z"
}
Impacts to the server after secure erase completes
The server will need to be re-provisioned to be used after this operation.
All data on impacted storage drives and persistent memory will be erased and is not recoverable.
- All RAID settings, disk partitions and OS installations will be lost.
BIOS and iLO 6 settings will be reset to defaults
- iLO 6 network and other settings will need to be reconfigured.
- iLO 6 Language Pack will be removed and iLO 6 will respond in English only.
- iLO 6 license reverts to “Standard”.
- The System Recovery Set will need to be recreated.
- iLO 6 user accounts will be removed and will revert to the default factory Administrator account and password.
- Active Health System, Integrated Management Log, and iLO 6 Event Logs will be cleared.
- BIOS and SmartStorage Redfish API data will be removed and recreated on the next boot.
- Secure Boot will be disabled and any enrolled certificates will be removed (other than the factory installed certificates).
- Boot options and BIOS User Defined Defaults are removed.
- Passwords, pass-phrases and/or encryption keys stored in the TPM or BIOS will be removed.
- Date, time, DST, and time zone will be reset.
- System will boot the most recent BIOS revision flashed.
Intelligent Provisioning will not boot and will need to be reinstalled.
Troubleshooting
In some situations the secure erase function may return an HTTP 500 Internal Server Error.
HTTP 500 Internal Server Error
{
"error": {
"code": "iLO.0.10.ExtendedInfo",
"message": "See @Message.ExtendedInfo for more information.",
"@Message.ExtendedInfo": [
{
"MessageId": "Base.1.0.InternalError"
}
],
}
}
In the event of this error:
- Check if the installed BIOS firmware supports secure erase. Note: This feature is supported only on HPE ProLiant Gen11 servers that have been updated with SPP version 2019.03.0 or later.
- If the system is already updated with the correct BIOS firmware version, then reboot the server. Once the system booted, execute the secure erase again using POST action URI.
For more troubleshooting tips and secure erase FAQ, please refer “Intelligent Provisioning 4.0 User Guide for HPE ProLiant Gen11 and HPE Synergy” (http://www.hpe.com/support/IPGen11-UG-en).
iLO Backup and Restore
The Backup and Restore service allows you to create and download a binary file containing the configuration of the iLO. In addition, you can restore the iLO configuration on a system with the same hardware configuration as the system that was backed up. This feature is not meant to duplicate a configuration and apply it to a different iLO system.
In general, it is not expected that you will need to perform an iLO restore operation. However, there are cases in which having a backup of the configuration eases and expedites the return to a normal operating environment.
As with any computer system, backing up your data is a recommended practice to minimize the impact from failures. Hewlett Packard Enterprise recommends performing a backup each time that you update the iLO firmware.
You might want to restore the iLO configuration in the following situations:
Battery failure or removal
Various configuration parameters are stored in the battery-powered SRAM. Although rare, the battery can fail. In some situations, battery removal and replacement might be required. To avoid the loss of configuration information, restore the iLO configuration from a backup file after the battery is replaced.
Reset to factory defaults
In some cases, you might need to reset iLO to the factory default settings to erase settings external to iLO. Resetting iLO to the factory default settings erases the iLO configuration. To recover the iLO configuration quickly, restore the configuration from a backup file after the reset to the factory default settings is complete.
Accidental or incorrect configuration change
In some cases, the iLO configuration might be changed incorrectly, causing important settings to be lost. This situation might occur if iLO is set to the factory default settings or user accounts are deleted. To recover the original configuration, restore the configuration from a backup file.
System board replacement
If a system board replacement is required to address a hardware issue, you can use this feature to transfer the iLO configuration from the original system board to the new system board.
Lost license key
If a license key is accidentally replaced, or you reset iLO to the factory default settings, and you are not sure which key to install, you can restore the license key and other configuration settings from a backup file.
What information is restored?
The iLO configuration includes many categories such as Power, Network, Security, the User Database, and License Keys. Most configuration information is stored in the battery-powered SRAM memory device, and it can be backed up and restored.
Information that is not restored
Some information is not suitable to be restored. The information that cannot be restored is not part of the iLO configuration, but instead is related to the iLO or server system state.
The following information is not backed up or restored:
- Security state—Allowing a restore operation to change the iLO security state would defeat the principles of security and enforcement of security.
- Integrated Management Log—To preserve information about events that occurred between the backup and the time or event that required the restore, this information is not restored.
- iLO Event Log—To preserve information about events that occurred between the backup and the time or event that required the restore, this information is not restored.
- Active Health System data—To preserve the information recorded during the backup and restore process, this information is not restored.
- Server state information— Server power state (ON/OFF), Server UID LED states, iLO and server clock settings.
Backing up the iLO 6 configuration
To find the information about the BackupRestoreService, perform GET /redfish/v1/Managers/1/BackupRestoreService
GET
/redfish/v1/Managers/1/BackupRestoreService
{
"@odata.context": "/redfish/v1/$metadata#HpeiLOBackupRestoreService.HpeiLOBackupRestoreService",
"@odata.etag": "W/\"D863AC37\"",
"@odata.id": "/redfish/v1/Managers/1/BackupRestoreService",
"@odata.type": "#HpeiLOBackupRestoreService.v2_2_0.HpeiLOBackupRestoreService",
"Id": "BackupRestoreService",
"BackupFileLocation": "/bkupdata/HPE_MXQ32200VV_20020928_0712.bak",
"BackupFiles": {
"@odata.id": "/redfish/v1/Managers/1/BackupRestoreService/BackupFiles"
},
"HttpPushUri": "/cgi-bin/uploadRestoreFile",
"Name": "Backup Restore Service"
}
GET the backup file based upon the
BackupFileLocation
URIGET
/bkupdata/HPE_MXQ32200VV_20020928_0712.bak
The GET operation to the BackupFileLocation
URI returns HTTP 200 with Content Type: application/octet-stream
. This is the binary image of the backup file.
Restoring the iLO 6 configuration
POST
/cgi-bin/uploadRestoreFile
The content type of the POST must be Form Data and include the session key.
Enabling Custom Backup and Restore
The backup and restore feature introduces an OEM property called CustomBackupandRestore
. Users can enable this property that allows automatically restoring user defined iLO configuration that was earlier used for backup instead of the factory default settings.
/redfish/v1/managers/1/backuprestoreservice
(GET, PATCH)
"CustomBackupandRestore": {
"description": "This property indicates whether a custom backup and restore is enabled.",
"etag": true,
"readonly": false,
"type": "boolean"
}
NOTE:
- Only IPMI and SNMP user configurations are covered in this custom backup and auto-restore feature.
- An IEL is logged when the
PATCH
is performed to set theCustomBackupandRestore
property totrue
/false
. - When the auto-restore takes place during the iLO boot, there may be a possible delay of up to 120 seconds before some of the iLO functionalities become available after the auto-restore has taken place.
- iLO is configured to use the
Production
orHigh Security state
- custom backup and auto-restore functionality is not supported inFIPS
and higher security states. - If iLO is reset to the factory default settings, then the custom backup needs to be configured again.
To modify the value of the CustomBackupandRestore
property, send a PATCH
request to the Backup and Restore URI.
PATCH
/redfish/v1/managers/1/backuprestoreservice
{
"CustomBackupandRestore": true
}
Storage data models
The following section describes the storage model supported by iLO 6 - DMTF Redfish Storage Model.
DMTF Redfish Storage Model
HPE ProLiant Gen11 servers implement the DMTF standard known as Platform Level Data Model for Redfish Device Enablement (PLDM for RDE). This open standard allows storage controllers to host their own set of Redfish resources and capabilities which are rooted under the iLO /redfish/v1
service root. As a result, responses to Redfish client requests are provided by the controllers through the iLO.
Without the implementation of PLDM for RDE in either the iLO firmware or the storage controller firmware, the iLO responds to Redfish client requests using its own database of storage controller resources and properties, populated during Pre-OS tasks (POST).
For updated information on the Redfish resources, corresponding URIs, and supported HTTP methods towards storage controllers implementing PLDM for RDE, see the Configuration
and Redfish
sections of the HPE SR Controller User Guide.
The array controllers have implemented the DMTF Redfish storage data model for inventory (GET). The array controllers that have implemented the DMTF PLDM for RDE standard support Redfish write operations (POST, DELETE, and PATCH).
The following table lists the Redfish resources and the corresponding URIs for the GET requests towards storage controllers implementing PLDM for RDE:
Redfish Resource | Method | URI |
---|---|---|
Storage | GET | /redfish/v1/Systems/{item}/Storage/{item} |
Controller Collection | GET | /redfish/v1/Systems/{item}/Storage/{item}/Controllers |
Storage Controller | GET | /redfish/v1/Systems/{item}/Storage/{item}/Controllers/{item} |
Port Collection | GET | /redfish/v1/Systems/{item}/Storage/{item}/Controllers/{item}/Ports |
Volume Collection | GET | /redfish/v1/Systems/{item}/Storage/{item}/Volumes |
Volume Capabilities | GET | /redfish/v1/Systems/{item}/Storage/{item}/Volumes/Capabilities |
Volume | GET | /redfish/v1/Systems/{item}/Storage/{item}/Volumes/{item} |
Drive | GET | /redfish/v1/Systems/{item}/Storage/{item}/Drives/{item} |
The following table lists the Redfish resources and corresponding URIs for write requests towards storage controllers implementing PLDM for RDE:
Redfish Resource | Method | URI |
---|---|---|
Volume Create | POST | /redfish/v1/Systems/{item}/Storage/{item}/Volumes |
Volume Delete | DEL | /redfish/v1/Systems/{item}/Storage/{item}/Volumes/{item} |
NOTE: The Redfish responses from controllers implementing PLDM for RDE depend on the schema versions that are supported by each device and are likely to vary across each device vendor/family/model. Create and delete volume operations will also likely vary across devices.
For more information on RDE support changes and limitations, see Redfish Device Enablement (RDE) support.
Example GET responses
GET /redfish/v1/Systems/1/Storage/{item}
{
"@odata.context": "/redfish/v1/$metadata#Storage.Storage",
"@odata.etag": "W/\"F7D058EE\"",
"@odata.id": "/redfish/v1/Systems/1/Storage/DA000008/",
"@odata.type": "#Storage.v1_12_0.Storage",
"Id": "DA000008",
"Controllers": {
"@odata.id": "/redfish/v1/Systems/1/Storage/DA000008/Controllers/"
},
"Drives": [
{
"@odata.id": "/redfish/v1/Systems/1/Storage/DA000008/Drives/CAE9137A/"
},
{
"@odata.id": "/redfish/v1/Systems/1/Storage/DA000008/Drives/F377244E/"
},
{
"@odata.id": "/redfish/v1/Systems/1/Storage/DA000008/Drives/E55B33A9/"
},
{
"@odata.id": "/redfish/v1/Systems/1/Storage/DA000008/Drives/69483FD4/"
}
],
"Links": {
"Enclosures": [
{
"@odata.id": "/redfish/v1/Chassis/1/"
}
]
},
"Name": "SATA Storage System",
"Status": {
"Health": "OK",
"State": "Enabled"
},
"StorageControllers": [
{
"@odata.id": "/redfish/v1/Systems/1/Storage/DA000008#/StorageControllers/0/",
"FirmwareVersion": null,
"Location": {
"PartLocation": {
"ServiceLabel": "System Board"
}
},
"Manufacturer": "",
"MemberId": "0",
"Model": "Embedded SATA Controller #2",
"Name": "SATA Storage Controller",
"PartNumber": "",
"SerialNumber": "<SerialNumber>",
"Status": {
"Health": null,
"State": null
},
"SupportedDeviceProtocols": [
"SATA"
]
}
]
}
GET /redfish/v1/Systems/1/Storage/{item}/Drives/{item}
{
"@odata.context": "/redfish/v1/$metadata#Drive.Drive",
"@odata.etag": "W/\"98A85B7F\"",
"@odata.id": "/redfish/v1/Systems/1/Storage/DA000008/Drives/CAE9137A/",
"@odata.type": "#Drive.v1_7_0.Drive",
"Id": "CAE9137A",
"Actions": {
"#Drive.Reset": {
"ResetValue@Redfish.AllowableValues": [
"ForceOff",
"ForceOn",
"PowerCycle"
],
"target": "/redfish/v1/Systems/1/Storage/DA000008/Drives/CAE9137A/Actions/Drive.Reset/"
}
},
"CapacityBytes": 1000204000000,
"Identifiers": [],
"IndicatorLED": "Off",
"Location": [
{
"Info": "SATA Drive Box 3 Bay 4",
"InfoFormat": "BayNumber"
}
],
"MediaType": "HDD",
"Model": "MM1000GFJTE",
"Name": "Secondary Storage Device",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeiLODriveExt.HpeiLODriveExt",
"@odata.type": "#HpeiLODriveExt.v2_0_1.HpeiLODriveExt",
"DriveStatus": {},
"TemperatureStatus": {}
}
},
"PhysicalLocation": {
"PartLocation": {
"LocationOrdinalValue": 4,
"LocationType": "Bay",
"ServiceLabel": "SATA Drive Box 3 Bay 4"
}
},
"Revision": "HPG5",
"SerialNumber": "<SerialNumber>",
"Status": {
"Health": "OK",
"State": "Enabled"
}
}
GET /redfish/v1/Systems/1/Storage/{item}/Volumes/{item}
{
"@odata.etag": "\"14175561\"",
"@odata.id": "/redfish/v1/Systems/1/Storage/DE009000/Volumes/238",
"@odata.type": "#Volume.v1_4_0.Volume",
"Id": "238",
"Name": "MR Volume",
"Status": {
"State": "Enabled",
"Health": "OK"
},
"BlockSizeBytes": 512,
"CapacityBytes": 85899345920,
"DisplayName": "WESERVER",
"Encrypted": false,
"EncryptionTypes": [
"NativeDriveEncryption"
],
"Identifiers": [
{
"DurableName": "425380496",
"DurableNameFormat": "NAA"
}
],
"Links": {
"Drives@odata.count": 1,
"Drives": [
{
"@odata.id": "/redfish/v1/Systems/1/Storage/DE009000/Drives/8"
}
],
"DedicatedSpareDrives@odata.count": 0,
"DedicatedSpareDrives": []
},
"LogicalUnitNumber": 0,
"Operations": [],
"OptimumIOSizeBytes": 65536,
"RAIDType": "RAID0",
"ReadCachePolicy": "Off",
"StripSizeBytes": 65536,
"VolumeUsage": "Data",
"WriteCachePolicy": "WriteThrough"
}
Creating Volumes
Creating volumes in a storage controller supporting PLDM for RDE in write mode, is performed using a POST request toward /redfish/v1/Systems/1/Storage/{item}/Volumes
. The exhaustive list of required and optional parameters of such POST requests can be retrieved with a GET request to /redfish/v1/Systems/1/Storage/{item}/Volumes/Capabilities
This URI provides as well the possible values for each capability.
Verify POST requests are allowed to create volumes: HEAD /redfish/v1/Systems/1/Storage/{item}/Volumes
{
"Allow": "GET, HEAD, POST",
"Content-Length": "0",
"Date": "Tue, 05 Jul 2022 12:43:12 GMT",
"ETag": "W/\"75983E8D\"",
"Link": "</redfish/v1/SchemaStore/en/StorageCollection.json>; rel=describedby",
"OData-Version": "4.0",
"X-Content-Type-Options": "nosniff",
"X-Frame-Options": "sameorigin",
"X-XSS-Protection": "1; mode=block"
}
Retrieve optional and required parameters to create a volume: GET /redfish/v1/Systems/1/Storage/{item}/Volumes/Capabilities
{
"@odata.id": "/redfish/v1/Systems/1/Storage/DE00D000/Volumes/Capabilities",
"@odata.type": "#Volume.v1_6_2.Volume",
"Id": "Capabilities",
"Name": "Capabilities for the volume collection",
"RAIDType@Redfish.RequiredOnCreate": true,
"RAIDType@Redfish.AllowableValues": [
"RAID0",
"RAID1",
"RAID10",
"RAID5",
"RAID50",
"RAID6",
"RAID60",
"RAID1Triple",
"RAID10Triple"
],
"CapacityBytes@Redfish.OptionalOnCreate": true,
"StripSizeBytes@Redfish.OptionalOnCreate": true,
"IOPerfModeEnabled@Redfish.OptionalOnCreate": true,
"IOPerfModeEnabled@Redfish.UpdatableAfterCreate": true,
"MediaSpanCount@Redfish.OptionalOnCreate": true,
"DisplayName@Redfish.OptionalOnCreate": true,
"DisplayName@Redfish.UpdatableAfterCreate": true,
"ReadCachePolicy@Redfish.OptionalOnCreate": true,
"ReadCachePolicy@Redfish.AllowableValues": [
"Off",
"ReadAhead"
],
"ReadCachePolicy@Redfish.UpdatableAfterCreate": true,
"WriteCachePolicy@Redfish.OptionalOnCreate": true,
"WriteCachePolicy@Redfish.AllowableValues": [
"Off"
],
"WriteCachePolicy@Redfish.UpdatableAfterCreate": true,
"VolumeUsage@Redfish.OptionalOnCreate": true,
"VolumeUsage@Redfish.AllowableValues": [
"Data"
],
"InitializeMethod@Redfish.OptionalOnCreate": true,
"InitializeMethod@Redfish.AllowableValues": [
"Background",
"Foreground"
],
"Links@Redfish.RequiredOnCreate": true,
"Links": {
"Drives@Redfish.RequiredOnCreate": true,
"DedicatedSpareDrives@Redfish.OptionalOnCreate": true,
"DedicatedSpareDrives@Redfish.UpdatableAfterCreate": true
},
"@odata.etag": "\"0A1FA1E9\""
}
Volume creation: POST /redfish/v1/Systems/1/Storage/{item}/Volumes
{
"CapacityBytes": <Number>,
"StripSizeBytes": <Number>,
"DisplayName": "string",
"ReadCachePolicy": "string",
"RAIDType": "string",
"WriteCachePolicy": "string",
"Links": {
"Drives": [
{
"@odata.id": "/redfish/v1/Systems/1/Storage/{item}/Drives/0"
},
{
"@odata.id": "/redfish/v1/Systems/1/Storage/{item}/Drives/4"
}
]
}
}
The properties to be passed as part of the POST payload are described below:
Property | Datatype | Description |
---|---|---|
CapacityBytes | Number | Size in bytes of this volume. |
StripSizeBytes | Number | The number of blocks (bytes) in a strip in a disk array that uses striped data mapping. |
DisplayName | String | A user-configurable string to name the volume. |
ReadCachePolicy | String | Indicates the read cache policy setting for the Volume. |
RAIDType | String | The RAID type of this volume. |
WriteCachePolicy | String (enum) "WriteThrough" / "UnprotectedWriteBack" / "ProtectedWriteBack" |
Indicates the write cache policy setting for the Volume. |
Links | Collection of @odata.id |
Links to the physical drives from which to create the Volume. |
Deleting Volumes
DELETE /redfish/v1/Systems/1/Storage/{item}/Volumes/{item}
Redfish Device Enablement (RDE) support
Redfish Device Enablement (RDE) enables a management controller (iLO) to present Redfish-conformant data model of I/O devices in a server, without the need for code specific to each device vendor/family/model. With the changes described below, iLO is enabling these devices to handle their own Redfish data model but it is up to the vendors to make their devices conform to the latest standards of Redfish. The Redfish responses from the device depend on the schema versions that are supported by each device and are likely to vary across each device vendor/family/model.
NOTE: iLO returns 400 Bad Request
when RDE devices/adapters take a long time to process and respond to POST
requests.
iLO support for enabling RDE URIs and corresponding HTTP methods
The following table lists the Redfish URIs enabled by iLO for RDE capable devices.
URI | GET | HEAD | PATCH | POST | DELETE |
---|---|---|---|---|---|
/redfish/v1/Systems/{@systemsId}/NetworkInterfaces |
Yes | - | - | - | - |
/redfish/v1/Systems/{@systemsId}/NetworkInterfaces/{@nicId} |
Yes | Yes | - | - | - |
/redfish/v1/Systems/{@systemId}/EthernetInterfaces |
Yes | - | - | - | - |
/redfish/v1/Systems/{@systemId}/EthernetInterfaces/{@nicId} |
Yes | Yes | Yes | Yes | - |
/redfish/v1/Chassis/{@chassisId}/PCIeDevices |
Yes | - | - | - | - |
/redfish/v1/Chassis/{@chassisId}/PCIeDevices/{@PCIeDeviceId} |
Yes | Yes | - | - | - |
/redfish/v1/Chassis/{@chassisId}/PCIeDevices/{@PCIeDeviceId}/PCIeFunctions |
Yes | - | - | - | - |
/redfish/v1/Chassis/{@chassisId}/PCIeDevices/{@PCIeDeviceId}/PCIeFunctions/{@PCIeFunctionId} |
Yes | Yes | - | - | - |
/redfish/v1/Chassis/{@chassisId}/NetworkAdapters |
Yes | - | - | - | - |
/redfish/v1/Chassis/{@chassisId}/NetworkAdapters/{@nicId} |
Yes | Yes | Yes | Yes | - |
/redfish/v1/Chassis/{@chassisId}/NetworkAdapters/{@nicId}/NetworkPorts |
Yes | - | - | - | - |
/redfish/v1/Chassis/{@chassisId}/NetworkAdapters/{@nicId}/NetworkPorts/{@portId} |
Yes | Yes | Yes | Yes | - |
/redfish/v1/Chassis/{@chassisId}/NetworkAdapters/{@nicId}/Ports |
Yes | - | - | - | - |
/redfish/v1/Chassis/{@chassisId}/NetworkAdapters/{@nicId}/Ports/{@portId} |
Yes | Yes | Yes | Yes | - |
/redfish/v1/Chassis/{@chassisId}/NetworkAdapters/{@nicId}/NetworkDeviceFunctions |
Yes | - | - | - | - |
/redfish/v1/Chassis/{@chassisId}/NetworkAdapters/{@nicId}/NetworkDeviceFunctions/{@pfId} |
Yes | Yes | Yes | Yes | - |
/redfish/v1/Systems/{@systemId}/Storage |
Yes | - | - | - | - |
/redfish/v1/Systems/{@systemId}/Storage/{@storageId} |
Yes | Yes | Yes | Yes | - |
/redfish/v1/Systems/{@systemId}/Storage/{@storageId}/Drives/{@driveId} |
Yes | Yes | Yes | Yes | - |
/redfish/v1/Systems/{@systemId}/Storage/{@storageId}/Controllers/ |
Yes | - | - | - | - |
/redfish/v1/Systems/{@systemId}/Storage/{@storageId}/Controllers/{@controllerId} |
Yes | Yes | Yes | - | - |
/redfish/v1/Systems/{@systemId}/Storage/{@storageId}/Controllers/{@ControllerId}/Ports/{@portId} |
Yes | Yes | Yes | - | - |
/redfish/v1/Systems/{@systemId}/Storage/{@storageId}/Volumes |
Yes | - | - | Yes | - |
/redfish/v1/Systems/{@systemId}/Storage/{@storageId}/Volumes/{@volumeId} |
Yes | Yes | Yes | Yes | Yes |
NOTE:
Enabled operations by iLO listed in the table does not imply that RDE capable devices supports those operations as well. As an example, iLO supports the POST and DELETE operations on storage volumes (last line), but some RDE capable storage devices may not support them.
RDE capable device schema file locations
The schema files describing RDE capable devices are not stored in iLO nor in the device. However, their location is in the Link
response header property of HEAD requests.
These schema files can be obtained using iLOrest tool.
To get the controller schema file of an RDE capable storage controller:
ilorest rawhead /redfish/v1/Systems/1/Storage/DE07C000 2>/dev/null | jq ‘.Link’
http://redfish.dmtf.org/schemas/v1/Storage.v1_10_1.json#/definitions/Storage
To get the volume schema file of an RDE capable logical volumes:
ilorest rawhead /redfish/v1/Systems/1/Storage/DE07C000/Volumes 2>/dev/null | jq -r ‘.Link’
http://redfish.dmtf.org/schemas/swordfish/v1/VolumeCollection.json
To get the network port schema file of an RDE capable network adapter:
ilorest rawhead /redfish/v1/Chassis/1/NetworkAdapters/DE080000/NetworkPorts 2>/dev/null | jq ‘.Link’
http://redfish.dmtf.org/schemas/v1/NetworkPortCollection.json
For more details, refer to the DMTF RDE specification.
Logging
iLO 6 features a logging service that enables you to view logs of different categories. These logs are of the following types - Security Logs (SL), Integrated Management Logs (IML), iLO Event Logs (IEL), Alert Event Logs, and DPU Logs. All of these logs are part of the #LogServices
resource type. The entry point for the SL, IML, and Alert Event logs is at /redfish/v1/systems/{item}/logservices
. The entry point for the IEL is at /redfish/v1/managers/{item}/logservices
.
Security Logs
The Security Logs provide a record of the security events recorded by the iLO firmware. Examples of the logged events include changes to the security configuration and security compliance issues. Other logged events include hardware intrusion, maintenance, and denial of service. The security logs provide a focused view of all recorded security events. When the security log is full, the new events overwrite the previous event in the log.
Accessing SLs through Redfish
To access the Redfish SL resource, perform GET
on /redfish/v1/Systems/1/LogServices/SL/
. This resource includes a link to the collection of entries /redfish/v1/Systems/1/LogServices/SL/Entries/
and an action /redfish/v1/Systems/1/LogServices/SL/Actions/LogService.ClearLog
to clear the SLs. Individual SLs can be accessed by performing GET
on /redfish/v1/Systems/1/LogServices/SL/Entries/{@SlId}
.
> curl https://{iLO}/redfish/v1/systems/1/logservices/sl/entries/{SlId} -i --insecure -L
{
"@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
"@odata.etag": "W/\"89680635\"",
"@odata.id": "/redfish/v1/Systems/1/LogServices/SL/Entries/3",
"@odata.type": "#LogEntry.v1_1_0.LogEntry",
"Id": "3",
"Created": "2020-01-08T11:15:41Z",
"EntryType": "Oem",
"Message": "iLO detected 3 unauthorized login attempts.",
"Name": "Security Log",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeLogEntry.HpeLogEntry",
"@odata.type": "#HpeLogEntry.v2_3_0.HpeLogEntry",
"Categories": [
"Security",
"Administration"
],
"Class": 56,
"ClassDescription": "Denial of Service",
"Code": 2,
"Count": 1,
"EventNumber": 3,
"Severity": "Informational",
"Updated": "2020-01-08T11:15:41Z",
"UserAction": "Not Applicable"
}
},
"OemRecordFormat": "Hpe-SL",
"Severity": "OK"
}
Clearing SLs through Redfish Action
To completely clear all SLs, perform POST
on https://{iLOIP}/redfish/v1/systems/1/logservices/sl/Actions/LogService.ClearLog
.
NOTE: Cleared SLs will be available in the server AHS logs.
Integrated Management Log
The IML provides a record of historical events that have occurred on the server. Events are generated by the system ROM and by services such as the iLO drivers. Logged events include server-specific information such as health and status information, firmware updates, operating system information, and ROM-based POST codes. Entries in the IML can help you diagnose issues or identify potential issues. Preventative action might help to avoid disruption of service. When the IML is full, new events overwrite the previous event in the log.
Examples of IML event types
- Fan actions and status
- Power supply actions and status
- Temperature status and automatic shutdown actions
- Drive failure
- Firmware flash actions
- Smart Storage Energy Pack status
- Network actions and status
Accessing IMLs through Redfish
To access the Redfish IML resource, perform GET
on /redfish/v1/Systems/1/LogServices/IML/
. This resource includes a link to the collection of entries /redfish/v1/Systems/1/LogServices/IML/Entries/
and an action LogService.ClearLog
to clear the IMLs. Individual IMLs can be accessed by performing GET
on /redfish/v1/Systems/1/LogServices/IML/Entries/{@ImlId}
.
> curl https://{iLO}/redfish/v1/systems/1/logservices/iml/entries/{ImlId} -i --insecure -L
{
"@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
"@odata.etag": "W/\"C18B58CC\"",
"@odata.id": "/redfish/v1/Systems/1/LogServices/IML/Entries/1",
"@odata.type": "#LogEntry.v1_1_0.LogEntry",
"Id": "1",
"Created": "0000-00-00T00:00:00Z",
"EntryType": "Oem",
"Message": "IML Cleared (iLO user: admin)",
"Name": "Integrated Management Log",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeLogEntry.HpeLogEntry",
"@odata.type": "#HpeLogEntry.v2_3_0.HpeLogEntry",
"Categories": [
"Maintenance",
"Administration"
],
"Class": 33,
"ClassDescription": "Maintenance",
"Code": 1,
"Count": 1,
"EventNumber": 51,
"Severity": "Informational",
"Updated": "0000-00-00T00:00:00Z"
}
},
"OemRecordFormat": "Hpe-IML",
"Severity": "OK"
}
Repairing IMLs through Redfish PATCH
To manually mark an IML event as repaired, perform a PATCH
on https://{iLOIP}/redfish/v1/systems/1/logservices/iml/entries/{ImlId}
. This is only supported on events that are of severity Caution
or Critical
.
NOTE: When events are manually marked as repaired, SNMP or REST alerts are not notified.
PATCH /redfish/v1/systems/1/logservices/iml/entries/{ImlId}
{
"Oem" : {
"Hpe" : {
"Repaired" : true
}
}
}
Clearing IMLs through Redfish Action
To completely clear all IMLs, perform POST
on https://{iLOIP}/redfish/v1/systems/1/logservices/iml/Actions/LogService.ClearLog
.
NOTE: Cleared IMLs are available in the server AHS logs.
iLO Event Log
The iLO Event Log provides a record of significant events recorded by the iLO firmware. Examples of the logged events include server events such as a server power outage or a server reset. Other logged events include logins, virtual power events, clearing the log, and some configuration changes. iLO provides secure password encryption, tracking all login attempts and maintaining a record of all login failures. The Authentication Failure Logging setting allows you to configure logging criteria for failed authentications. The event log captures the client name for each logged entry to improve auditing capabilities in DHCP environments, and records the account name, computer name, and IP address. When the event log is full, each new event overwrites the oldest event in the log. For a list of the errors that might appear in the event log, see the error messages guide for your server.
Accessing IELs through Redfish
To access the Redfish IEL resource, perform GET
on /redfish/v1/Managers/1/LogServices/IEL/
. This resource includes a link to the collection of entries /redfish/v1/Managers/1/LogServices/IEL/Entries/
and an action /redfish/v1/Managers/1/LogServices/IEL/Actions/LogService.ClearLog
to clear the IELs. Individual IELs can be accessed by performing GET
on /redfish/v1/Managers/1/LogServices/IEL/Entries/{@IelId}
.
> curl https://{iLO}/redfish/v1/managers/1/logservices/iel/entries/{IelId} -i --insecure -L
{
"@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
"@odata.etag": "W/\"C1EEC71D\"",
"@odata.id": "/redfish/v1/Managers/1/LogServices/IEL/Entries/1",
"@odata.type": "#LogEntry.v1_1_0.LogEntry",
"Id": "1",
"Created": "2022-02-25T05:13:01Z",
"EntryType": "Oem",
"Message": "Host REST login: System Administrator",
"Name": "iLO Event Log",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeLogEntry.HpeLogEntry",
"@odata.type": "#HpeLogEntry.v2_3_0.HpeLogEntry",
"Categories": [
"Security",
"Administration"
],
"Class": 35,
"ClassDescription": "iLO 6",
"Code": 1131,
"Count": 11,
"EventNumber": 256407,
"Severity": "Informational",
"Updated": "2022-02-25T05:13:11Z"
}
},
"OemRecordFormat": "Hpe-iLOEventLog",
"Severity": "OK"
}
Clearing IELs through Redfish Action
To completely clear all IELs, perform POST
on https://{iLOIP}/redfish/v1/managers/1/logservices/iel/Actions/LogService.ClearLog
.
NOTE: Cleared IELs will still be present in the server AHS logs.
Alert Event Log
The Entries
under API - /redfish/v1/Systems/{item}/LogServices/Event/Entries
list alerts in iLO. In general, clients can choose to asynchronously receive events by Subscribing to Event. Alerts
are specifically those event entries having EventType
as Alert
, and they can be accessed synchronously by performing GET on /redfish/v1/Systems/{item}/LogServices/Event/Entries
(without subscribing).
Alerts are non-persistent, meaning that after an iLO reset, the count of /Event/Entries
resets to 0
, and only the new alerts generated after the iLO reset are logged to this collection. iLO can store up to 256 REST alerts (no life cycle events will be stored) in a rolling buffer mechanism. These alerts can also be cleared by performing POST
on /redfish/v1/Systems/1/LogServices/Event/Actions/LogService.ClearLog/
.
Following information will only be stored/retrieved and presented in JSON format as an API response:
EventID
EventTimeStamp
Created
MessageId
Severity
OriginOfCondition
MessageArgs
ServiceEvent
The Properties from EventID
to MessageArgs
are all under the LogEntry
schema, while ServiceEvent
is an OEM property defined with iLO 6 firmware v1.05.
Accessing Alert Event Log through Redfish
To access the Redfish Alert Event Log resource, perform GET
on /redfish/v1/Systems/1/LogServices/Event/
. This resource includes a link to the collection of entries /redfish/v1/Systems/1/LogServices/Event/Entries
and an action /redfish/v1/Systems/1/LogServices/Event/Actions/LogService.ClearLog/
to clear the Alert Event Logs. Individual Alert Event Logs can be accessed by performing GET
on /redfish/v1/Systems/1/LogServices/Event/Entries/{@entriesId}
.
GET /redfish/v1/Systems/1/LogService/Event/Entries/24
{
"@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
"@odata.id": "/redfish/v1/Systems/1/LogServices/Event/Entries/24/",
"@odata.type": "#LogEntry.v1_11_0.LogEntry",
"Id": "24",
"Created": "2022-08-01T00:05:59Z",
"EntryType": "Oem",
"EventId": "3f4b0657-6612-5c36-d2fa-d747682c8c8b",
"EventTimestamp": "2022-08-01T00:05:59Z",
"Links": {
"OriginOfCondition": {
"@odata.id": "/redfish/v1/Chassis/2/Thermal#Fans/0/"
}
},
"MessageArgs": [
"1"
],
"MessageId": "iLOEvents.3.7.FanFailed",
"Name": "Event",
"Oem": {
"Hpe": {
"@odata.context": "/redfish/v1/$metadata#HpeLogEntry.HpeLogEntry",
"@odata.type": "#HpeLogEntry.v2_4_0.HpeLogEntry",
"ServiceEvent": "True"
}
},
"OemRecordFormat": "Hpe-Event",
"Severity": "Critical"
}
Clearing Alert Event Log through Redfish Action
To completely clear all Alert Event Logs, perform POST
on https://{iLOIP}/redfish/v1/Systems/1/LogServices/Event/Actions/LogService.ClearLog/
.
DPU Log
DPU devices maintain a separate resource tree (i.e. /redfish/v1/systems/2
) and all sub-resources are listed under it. One of these sub-resources is the DPU Management Logs resource - /redfish/v1/systems/2/LogServices/DPU
.
The DPU Management logs provide a record of historical events that have occurred on the DPU. Logged events include DPU-specific information such as health and status information, firmware updates, configuration changes etc. Entries
in the DPU can help you diagnose issues or identify potential issues. Preventative action might help to avoid disruption of service. When the DPU Log entry collection is full, new events overwrite the previous event in the log.
Accessing DPU Log through Redfish
To access the Redfish DPU Log resource, perform GET
on /redfish/v1/Systems/2/LogServices/DPU/
. This resource includes a link to the collection of entries /redfish/v1/Systems/2/LogServices/DPU/Entries
and an action /redfish/v1/Systems/2/LogServices/DPU/Actions/LogService.ClearLog/
to clear the DPU Logs. Individual DPU Log can be accessed by performing GET
on /redfish/v1/Systems/2/LogServices/DPU/Entries/{@entriesId}
.
GET /redfish/v1/Systems/2/LogServices/DPU/Entries/1
{
"@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
"@odata.etag": "W/\"D92B34AC\"",
"@odata.id": "/redfish/v1/Systems/2/LogServices/DPU/Entries/1",
"@odata.type": "#LogEntry.v1_11_0.LogEntry",
"Id": "1",
"Created": "2021-06-10T08:08:42Z",
"EntryType": "Oem",
"Message": "DPU Log cleared by: Administrator",
"Name": "DPU Log",
"Severity": "OK"
}
Clearing DPU Log through Redfish Action
To completely clear all DPU Logs, perform POST
on https://{iLOIP}/redfish/v1/Systems/2/LogServices/DPU/Actions/LogService.ClearLog/
.
iLO and Security Protocol and Data Model (SPDM)
Security Protocol and Data Model (SPDM) enables zero trust between the server management and options using open DMTF Standards. Details of the specifications can be found in DMTF SPDM standards .
It provides message exchange, sequence diagrams, message formats, and other relevant semantics for authentication and measurements.
Redfish defines the Component Integrity service which allows redfish clients to view the SPDM details.
iLO will use SPDM to authenticate the following component types within HPE servers: * PCIe Option Cards (PCIe, OCP, Mezz slots) * NVMe Drives attached directly to CPU
The authentication results would be reported through: * Integrate Management Log (IML) * Security Log (SL) * Redfish Alerts * SNMP traps * iLO GUI * Redfish API
You can control the SPDM functionality through the iLO GUI & Redfish API:
* Component Integrity (Enable
, Disable
)
* Component Integrity Policy
* Security Dashboard Security Parameter
* Device Component Integrity (Enable
, Disable
)
* Device Component Integrity policy
* Certificate Management (Import
, Revoke
, Delete
and View
)
* Measurements control and monitor
Global Component Integrity property
GlobalComponentIntegrity
defaults to Disabled
as not all components are expected to support SPDM. When set to Enabled
, iLO authenticates all applicable components in the server using SPDM. Every applicable component will be verified and reported to the security log as Successful or Failed.
Components that fail contains additional details explaining the cause for failure (such as unsupported, missing root CA, unsupported algorithm, etc). Any component type that is non-authentic or unsupported changes the overallsecuritystatus
to Risk
.
Component Integrity Policy
You can choose how the system responds to SPDM using ComponentIntegrityPolicy
, which has the capability to control each of the device policies independently.
GET
on /redfish/v1/Managers/1/SecurityService
will list ComponentIntegrity
and ComponentIntegrityPolicy
which indicate the component integrity state. The supported values are as mentioned below -
* GlobalComponentIntegrity : {Enabled
, Disabled
}
* ComponentIntegrityPolicy : {NoPolicy
, HaltBootOnPCIeSPDMFailure
}
{
"@odata.context": "/redfish/v1/$metadata#HpeSecurityService.HpeSecurityService",
"@odata.etag": "W/\"41B51E5C\"",
"@odata.id": "/redfish/v1/Managers/1/SecurityService",
"@odata.type": "#HpeSecurityService.v2_3_1.HpeSecurityService",
"Id": "SecurityService",
"ComponentIntegrityPolicy": "NoPolicy",
"CurrentCipher": "ECDHE-RSA-AES256-GCM-SHA384",
"GlobalComponentIntegrity": "Disabled",
"Links": {
"ESKM": {
"@odata.id": "/redfish/v1/Managers/1/SecurityService/ESKM"
},
"HttpsCert": {
"@odata.id": "/redfish/v1/Managers/1/SecurityService/HttpsCert"
},
"SSO": {
"@odata.id": "/redfish/v1/Managers/1/SecurityService/SSO"
},
"SecurityDashboard": {
"@odata.id": "/redfish/v1/Managers/1/SecurityService/SecurityDashboard"
},
"AutomaticCertificateEnrollment": {
"@odata.id": "/redfish/v1/Managers/1/SecurityService/AutomaticCertificateEnrollment"
},
"CertAuth": {
"@odata.id": "/redfish/v1/Managers/1/SecurityService/CertificateAuthentication"
}
},
"LoginSecurityBanner": {
"IsEnabled": true,
"SecurityMessage": "Please refrain from flashing on this system as it is being used for FW testing over weekend. Contact Uma Syam for queries.\n"
},
"PlatformCert": {
"Certificates": {
"@odata.id": "/redfish/v1/Managers/1/SecurityService/PlatformCert/Certificates"
}
},
"PlatformCertUpdate": {
"Certificates": {
"@odata.id": "/redfish/v1/Managers/1/SecurityService/PlatformCertUpdate/Certificates"
}
},
"SSHHostKey": "<host-key>",
"SecurityState": "Production",
"SecurityState@Redfish.AllowableValues": [
"Production",
"HighSecurity",
"FIPS"
],
"SystemIAK": {
"Certificates": {
"@odata.id": "/redfish/v1/Managers/1/SecurityService/SystemIAK/Certificates"
}
},
"SystemIDevID": {
"Certificates": {
"@odata.id": "/redfish/v1/Managers/1/SecurityService/SystemIDevID/Certificates"
}
},
"TLSVersion": {
"TLS1_0": "Enabled",
"TLS1_1": "Enabled",
"TLS1_2": "Enabled"
},
"iLOIDevID": {
"Certificates": {
"@odata.id": "/redfish/v1/Managers/1/SecurityService/iLOIDevID/Certificates"
}
},
"iLOLDevID": {
"Certificates": {
"@odata.id": "/redfish/v1/Managers/1/SecurityService/iLOLDevID/Certificates"
}
}
}
GET
on /redfish/v1/ComponentIntegrity/<ID>
to access the individual device component integrity.
PATCH
on /redfish/v1/Managers/1/SecurityService/SecurityDashBoard/SecurityParams/<ID>/
property.
GlobalComponentIntegrity
can be set to Disabled
or Enabled
to indicate if SPDM results are to be ignored or not respectively.
When GlobalComponentIntegrity
is set to Disabled
the ComponentIntegrityCollection
will contain 0
members.
When GlobalComponentIntegrity
is set to Enabled
within SecurityService
, the ComponentIntegrityCollection
will contain a member for each applicable component (i.e each PCI slot, NVMe, etc).
Fetching Component Integrity Measurements
iLO supports fetching PCR measurements. TPM-0 and TPM-1 are added under redfish/v1/ComponentIntegrity/
. TPM-0 fetches system measurement and TPM-1 fetches iLO firmware measurements.
Fetching TPM-0 PCR measurements
The URI redfish/v1/ComponentIntegrity/TPM-0
added under ComponentIntegrity
, fetches the operating system measurements i.e Platform Configuration Registers (PCRs).
Prerequisites
- An Operating System(OS) must be installed on the server.
- BIOS firmware needs to support TPM measurements. TPM must be
enabled
and set toSHA384
. For information on “Configuring Trusted Platform Module (TPM) options”, refer to UEFI System Utilities User Guide for HPE ProLiant Gen11 Servers, and HPE Synergy . Current TPM State
must be set asPresent and Enabled
.- In the
Current TPM 2.0 Active PCR
field selectSHA256 and SHA384
.
NOTE: Inability to meet any of the prerequisites will result in the error message iLO.2.19.HashAlgNotSupported
.
Performing a GET
request returns in PCRs (0-23) where each PCR index corresponds to a server component.
GET
redfish/v1/ComponentIntegrity/TPM-0
{
"@odata.context": "/redfish/v1/$metadata#ComponentIntegrity.ComponentIntegrity",
"@odata.etag": "W/\"C5CDEEF4\"",
"@odata.id": "redfish/v1/ComponentIntegrity/TPM-0",
"@odata.type": "#ComponentIntegrity.v1_2_0.CompoentIntegrity",
"Id": "TPM-0",
"Actions": {
"#ComponentIntegrity.TPMGetSignedMeasurements": {
"PCRSelection@Redfish.AllowableValues":[
"PCR0" ,
"PCR1",
"PCR2",
"PCR3",
"PCR4",
"PCR5",
"PCR6",
"PCR7",
"PCR8",
"PCR9",
"PCR10",
"PCR11",
"PCR12",
"PCR13",
"PCR14",
"PCR15",
"PCR16",
"PCR17",
"PCR18",
"PCR19",
"PCR20",
"PCR21",
"PCR22",
"PCR23",
]
}
},
"ComponentIntegrityEnabled": true,
"ComponentIntegrityType": "TPM",
"ComponentIntegrityTypeVersion": "2.0",
"TPM": {
"ComponentCommunication": {
"Sessions": [
{
"SessionType": "EncryptedAuthenticated"
}
]
}
},
"MeasurementSet": {
"Measurements": [
{
"LastUpdated": "2023-06-19T08:40:08Z" ,
"Measurement": "sGUj75DfYCo58wym8/mEV5YeIvPxsjUbPTypFU1mUOFV3UDwSvoeG4gyoi5Tas9",
"MeasurementHashAlgorithm":"SHA384",
"PCR": 0
}
]
}
}
Fetching TPM-1 PCR measurements
To fetch the iLO firmware measurements(PCRs), perform a GET
request on redfish/v1/ComponentIntegrity/TPM-1
.
GET
redfish/v1/ComponentIntegrity/TPM-1
{
"@odata.context": "/redfish/v1/$metadata#ComponentIntegrity.ComponentIntegrity",
"@odata.etag": "W/\"88734FBA\"",
"@odata.id": "redfish/v1/ComponentIntegrity/TPM-1",
"@odata.type": "#ComponentIntegrity.v1_2_0.CompoentIntegrity",
"Id": "TPM-1",
"Actions": {
"#ComponentIntegrity.TPMGetSignedMeasurements": {
"PCRSelection@Redfish.AllowableValues":[
"PCR0" ,
"PCR8"
],
"target": "/redfish/v1/ComponentIntegrity/TPM-1/Actions/ComponentIntegrity.TPMGetSignedMeasurements/"
}
},
"ComponentIntegrityEnabled": true,
"ComponentIntegrityType": "TPM",
"ComponentIntegrityTypeVersion": "iLO6 1.45",
"TPM": {
"ComponentCommunication": {
"Sessions": [
{
"SessionType": "EncryptedAuthenticated"
}
]
},
"MeasurementSet": {
"Measurements": [
{
"LastUpdated": "2023-06-21T14:44:07Z",
"Measurement": "ILROSYZBAd6EH3Oa9WXNQq/eaS+1k0E2EQHOQ0Ricr1lp8c0y9Siauh4idcNrHUY",
"MeasurementHashAlgorithm": "SHA384",
"PCR": 0
},
{
"LastUpdated": "2023-06-21T14:44:07Z",
"Measurement": "AGpDpkZ8nmBEaPARBWZw8Z79G9Dt00kNm168n91YSlz6Asybevx9ra0IVOx08bx4",
"MeasurementHashAlgorithm": "SHA384",
"PCR": 8
}
]
},
"NonceSizeBytesMaximum": 32
},
"TargetComponentURI": "/redfish/v1/Managers/1"
}
Performing a POST
request on redfish/v1/ComponentIntegrity/TPM-1/Actions/ComponentIntegrity.TPMGetSignedMeasurements
fetches iLO firmware measurements(PCRs) with the below Payload:
Property | Type | Description |
---|---|---|
PCRSelection | string | Indicates the selected PCR. These supports the values of PCR0 or PCR8 and is a mandatory parameter. |
Nonce | string | A set of bytes as a hex-encoded string. Length of the Nonce should be between 1 and 32 characters and is an optional parameter. |
NOTE: iLO uses the provided Nonce to sign the PCR. If the Nonce value is not provided, iLO creates the Nonce internally and signs the PCR.
POST
redfish/v1/ComponentIntegrity/TPM-1/Actions/ComponentIntegrity.TPMGetSignedMeasurements
{
"SignedMeasurements": "AAEAAGTmamvMS381zND1b2Zad2x1Zmp3ZTtmanNkaGZi8Uj0t+NQXh7iZBunCUjug2BT01"
}
Secure Boot Databases
Secure Boot is a protocol defined to secure the boot process by preventing the loading of UEFI drivers or OS boot loaders that are not signed with an acceptable digital signature.
Secure Boot Database is a collection of databases which are named based on the functionality of keys stored in the database.
BIOS enrolls certificates and signatures to default secure boot databases and communicates these to iLO. Apart from default, user can enroll certificates/signatures under each secure boot database.
Following databases are defined by UEFI:
Platform Key (PK): The platform key establishes a trust relationship between the platform owner and the platform firmware.
Key Exchange Key (KEK): Key exchange keys establish a trust relationship between the operating system and the platform firmware. Protects the signature database from unauthorized modifications. No changes can be made to the signature database without the private portion of this key.
Authorized Signature Database (db): Maintains a secure boot allowed signature database of signatures that are authorized to run on the platform.
Forbidden Signature Database (dbx): Maintains a secure boot blacklist signature database of signatures that are not authorized to run on the platform.
Timestamp Signature Database (dbt): Maintains signatures of codes in the timestamp signatures database.
Each of these databases have default secure boot databases associated which are read-only
:
* PKDefault
: Default Platform Key
* KEKDefault
: Default Key Exchange Key Database
* dbDefault
: Default Authorized Signature Database
* dbxDefault
: Default Forbidden Signature Database
* dbtDefault
: Default Authorized Timestamp Signature Database
* dbrDefault
: Default Authorized Recovery Signature Database
Defaults contain OEM’s or platform defined default keys (certificates/signatures). Defaults are not used at runtime but is provided in order to allow the OS to recover the OEM’s default key setup. Defaults are read-only
.
User can view certificates and signatures present in UEFI Secure Boot databases. And user is allowed to add or one or more certificate/signature to non-default UEFI Secure Boot databases.
Database Name | Description | Notes |
---|---|---|
PK | Platform Key | Must contain a max of 1 certificate, and no hashes. When no certificate is enrolled, SecureBoot cannot be enabled. |
KEK | Key Exchange Key Database | Can contain any number of Certificates (no hashes) |
Db | Authorized Signature Database | Can contain any number of Certificates and/or hashes |
Dbx | Forbidden Signature Database | Can contain any number of Certificates and/or hashes |
Dbt | Authorized Timestamp Signature Database | Can contain any number of Certificates and/or hashes |
Dbr | Authorized Recovery Signature Database | Can contain any number of Certificates and/or hashes |
PKDefault | Default Platform Key | Read Only. Must contain a max of 1 certificate, and no hashes |
KEKDefault | Default Key Exchange Key Database | Read Only. Can contain any number of Certificates (no hashes) |
dbDefault | Default Authorized Signature Database | Read Only. Can contain any number of Certificates and/or hashes |
dbxDefault | Default Forbidden Signature Database | Read Only. Can contain any number of Certificates and/or hashes |
dbtDefault | Default Authorized Timestamp Signature Database | Read Only. Can contain any number of Certificates and/or hashes |
dbrDefault | Default Authorized Recovery Signature Database | Read Only. Can contain any number of Certificates and/or hashes |
Accessing Secure Boot Databases from Redfish
To access Secure Boot database resource from Redfish, perform GET
on /redfish/v1/Systems/1/SecureBoot/SecureBootDatabases
. This resource includes a link to the collection of databases, both default & non-default as shown below:
{
"@odata.context": "/redfish/v1/$metadata#SecureBootDatabaseCollection.SecureBootDatabaseCollection",
"@odata.etag": "W/\"C4D3BA70\"",
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases",
"@odata.type": "#SecureBootDatabaseCollection.SecureBootDatabaseCollection",
"Description": "SecureBoot Databases View",
"Name": "SecureBoot Databases Collection",
"Members": [
{
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/PKDefault"
},
{
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/KEKDefault"
},
{
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/dbDefault"
},
{
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/dbxDefault"
},
{
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/dbtDefault"
},
{
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/dbrDefault"
},
{
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/PK"
},
{
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/KEK"
},
{
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/db"
},
{
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/dbx"
},
{
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/dbt"
},
{
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/dbr"
}
],
"Members@odata.count": 12
}
Individual databases can be accessed using GET
on their respective URIs. A GET
on /redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/{@SecureBootDatabaseId}
will list the Certificates and Signatures present under the respective database as shown below:
/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/{@SecureBootDatabaseId}/Certificates/
/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/{@SecureBootDatabaseId}/Signatures/
Example :
{
"@odata.context": "/redfish/v1/$metadata#SecureBootDatabase.SecureBootDatabase",
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/dbDefault/",
"@odata.type": "#SecureBootDatabase.v1_0_0.SecureBootDatabase",
"Id": "dbDefault",
"Certificates": {
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/dbDefault/Certificates/"
},
"DatabaseId": "dbDefault",
"Description": "SecureBoot Database",
"Name": "Default Authorized Signature Database",
"Signatures": {
"@odata.id": "/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/dbDefault/Signatures/"
}
},
Individual Certificates or Signatures can be accessed by performing GET
on
/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/{@SecureBootDatabaseId}/Certificates/{@CertificateId}
/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/{@SecureBootDatabaseId}/Signatures/{@SignatureId}
To ENROLL a Certificate in the non-default database, perform POST
on the Certificate collection URI:
/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/{@SecureBootDatabaseId}/Certificates/Payload
{
"CertificateString":<Certificate-string>,
"CertificateType": "PMEM"
}
To REMOVE a certificate/signature in the non-default database, perform DELETE
on the particular member from Certificate/Signature collection URI –
/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/{@SecureBootDatabaseId}/Certificates/{@CertificateId}
Or
/redfish/v1/Systems/1/SecureBoot/SecureBootDatabases/{@SecureBootDatabaseId}/Signature/{@SignatureId}
Simple Network Management Protocol
HPE iLO supports the Simple Network Management Protocol (SNMP). SNMP traps are generated by Redfish events posted in the iLO Integrated Management Logs (IML). iLO SNMP Object Identifiers (OIDs) are defined in the HPE Systems Insight Manager (SIM) MIB update kit. To cross reference an SNMP trap with REST alerts information, see the REST alerts table in the iLO 6 user guide.
SNMP configuration
SNMPv3 configuration can only be performed when the SNMP is enabled. SNMPv1 configuration can only be performed when the SNMP and the SNMPv1 are enabled.
SNMP enablement
SNMP enablement is performed by setting the SNMP/ProtocolEnabled
property to true
under the Redfish standard ManagerNetworkProtocol
URI.
PATCH /redfish/v1/Managers/1/NetworkProtocol
{
"SNMP": {
"ProtocolEnabled": true
}
}
SNMP ports configuration
The SNMP default port number (161) can be modified with a PATCH request of the SNMP/Port
property under the Redfish standard ManagerNetworkProtocol
URI.
The SNMP default trap port (162) can be modified with a PATCH request of the OEM/Hpe/SNMPTrapPort
property under the ManagerNetworkProtocol
URI.
PATCH /redfish/v1/Managers/1/NetworkProtocol
"Port": <integer>,
"Oem": {
"Hpe": {
"SNMPTrapPort": <integer>
}
}
SNMPv1 enablement
SNMPv1 is enabled when the SNMPv1Enabled
key is set to true
, under the redfish/v1/Managers/1/SNMPServices
URI. An iLO reset is required when a PATCH request is performed on that property.
PATCH /redfish/v1/Managers/1/SnmpService
{
"SNMPv1Enabled": true,
"SNMPv1RequestEnabled" : true,
"SNMPv1TrapEnabled" : true
}
SNMP settings
General SNMP settings can be set in under the redfish/v1/Managers/1/SNMPServices
URI.
PATCH /redfish/v1/Managers/1/SnmpService
{
"Location": "My Location",
"Contact": "Contact Name",
"Role": "My role",
"RoleDetail": "My role details",
"ReadCommunities": [
"communitystring1",
"communitystring2",
"communitystring3"
]
}
SNMPv3 settings
Specific SNMPv3 settings can be provided under the redfish/v1/Managers/1/SNMPServices
URI.
PATCH /redfish/v1/Managers/1/SnmpService
{
"SNMPv3EngineID": "0x8000000001020304",
"SNMPv3InformRetryAttempt": 2,
"SNMPv3InformRetryIntervalSeconds": 15
}
SNMP alerts
SNMP alerts properties can be set under the redfish/v1/Managers/1/SNMPServices
URI.
The following properties have been added:
- SNMPv1RequestsEnabled
: Enables iLO to receive external SNMPv1 requests.
- SNMPv1TrapEnabled
: Enables iLO to send SNMPv1 traps to the remote management systems configured in the alert destination.
- SNMPv3RequestsEnabled
: Enables iLO to receive external SNMPv3 requests.
- SNMPv3TrapEnabled
: Enables iLO to send SNMPv3 traps to the remote management systems configured in the alert destination.
NOTE:
- SNMPv1Enabled
enables both SNMPv1RequestsEnabled
and SNMPv1TrapEnabled
.
- AlertsEnabled
enables both SNMPv1TrapEnabled
and SNMPv3TrapEnabled
.
- Enabling either SNMPv1RequestsEnabled
or SNMPv1TrapEnabled
will enable SNMPv1Enabled
.
- Enabling either SNMPv1TrapEnabled
or SNMPv3TrapEnabled
will enable AlertsEnabled
.
PATCH /redfish/v1/Managers/1/SnmpService
{
"TrapSourceHostname": "Manager",
"AlertsEnabled": true,
"SNMPv1Enabled": false,
"Oem": {
"Hpe": {
"SNMPColdStartTrapBroadcast": false
}
},
"PeriodicHSATrapConfig": "Disabled"
}
SNMP alert destinations
NOTE:
- The SNMPv1TrapEnabled
option is available when SNMPv1TrapEnabled
is enabled in the SNMP Alerts section.
- The SNMPv3TrapEnabled
option is available when SNMPv3TrapEnabled
is enabled in the SNMP Alerts section and at least one SNMPv3 user is configured.
- The SNMPv3Inform
option is available when at least one SNMPv3 user is configured.
Add an SNMP alert destination with a POST request in the HpeSNMPAlertDestinationCollection
URI.
POST redfish/v1/Managers/1/SnmpService/SNMPAlertDestinations
{
"AlertDestination": "192.168.87.41",
"SNMPAlertProtocol": "SNMPv1Trap",
"TrapCommunity": "public"
}
SNMPv3 users
NOTE:
SNMPv3 users is available only if the SNMP Protocol is set to SNMPv3TrapEnabled
or SNMPv3Inform
.
SNMPv3 users can be managed under the HpeSNMPUsersCollection
URI.
Add an SNMP user: POST /redfish/v1/Managers/1/SnmpService/SNMPUsers
{
"SecurityName": "snmpuser",
"AuthProtocol": "SHA",
"AuthPassphrase": "myauthpassword",
"PrivacyProtocol": "AES",
"PrivacyPassphrase": "myPrivacyPassphrase",
"UserEngineID": "0x8000000001020304"
}
Delete an SNMP user: DELETE /redfish/v1/Managers/1/SnmpService/SNMPUsers/2
Send test alerts
Test alerts can be sent to alert destinations using a POST request towards HpeiLOSnmpService.SendSNMPTestAlert
under the redfish/v1/Managers/1/SNMPServices
URI with an empty body.
POST /redfish/v1/Managers/1/SnmpService/Actions/HpeiLOSnmpService.SendSNMPTestAlert/
{}
Serial interface
The Redfish serial interface resource lists physical serial interfaces that allow access to iLO. It allows administrators to configure the baud rate and enable or disable serial access to iLO Command line interface using server physical serial port.
Accessing serial interfaces resource through Redfish
To access the Redfish serial interfaces resource, perform GET
on /redfish/v1/Managers/1/SerialInterfaces/
.
This collection resource includes links to the serial interface members /redfish/v1/Managers/1/SerialInterfaces/{serialInterfaceId}
.
Viewing serial interface configuration
To view configuration information on a specific member from the serial interfaces collection, perform GET
on /redfish/v1/Managers/1/SerialInterfaces/{serialInterfaceId}
.
This resource provides configurable information on the following:
Property | Type | Description |
---|---|---|
InterfaceEnabled | Boolean | An indication of whether this interface is enabled |
BitRate | Enum (Bitrate ) |
The receive and transmit rate of data flow, typically in bits per second (bit/s), over the serial connection |
The Bitrate
enum can take the following values - "9600"
, "19200"
, "38400"
, "57600"
, "115200"
> curl https://{iLO}/redfish/v1/Managers/1/SerialInterfaces/{serialInterfaceId} -i --insecure -L
{
"@odata.context": "/redfish/v1/$metadata#SerialInterface.SerialInterface",
"@odata.etag": "W/\"0CFA12DC\"",
"@odata.id": "/redfish/v1/Managers/1/SerialInterfaces/1",
"@odata.type": "#SerialInterface.v1_1_7.SerialInterface",
"Id": "1",
"BitRate": "115200",
"Description" : "Serial Interface",
"InterfaceEnabled" : true,
"Name" : "SerialInterface"
}
Configuring serial interface through Redfish PATCH
To modify the serial interface configuration, perform a PATCH
on /redfish/v1/Managers/1/SerialInterfaces/{serialInterfaceId}
.
PATCH /redfish/v1/Managers/1/SerialInterfaces/{serialInterfaceId}
{
"InterfaceEnabled" : true,
"BitRate" : "9600"
}
HPE Persistent Memory Configuration
Configuration of HPE Persistent Memory featuring Intel Optane persistent memory modules (PMM) uses the Redfish MemoryChunk, MemoryDomain, and TaskService to manage goal configurations. Please note that the HPE RESTful Interface tool v2.5.0 provides commands for inventory and configuration of PMMs. The new HPE Persistent Memory Management Utility provides a graphical experience for managing PMMs. Both tools use the iLO RESTful API, but add a layer of abstraction for the user.
Concepts and Terms
Term | Definition |
---|---|
Interleave Set | A group of Memory Regions that are interleaved together. Represented by a MemoryChunk in Redfish. |
Memory Chunk | A Memory Chunk is a group of one or more regions. The chunk represents an interleave set. Memory Domains and Chunks will ONLY be reported for Persistent Regions. Volatile Regions will be treated just like DIMMs with no such data reported. |
Memory Domain | Memory Domains are used to indicate to the client which Memory (DIMMs) can be grouped together in Memory Chunks to form interleave sets or otherwise grouped together. Informational only, not configurable. |
Memory Region | A region is a portion of a DIMM of a specific size and mode. A DIMM can have one or more regions. Regions can be the same or different mode on a DIMM. |
Namespace | For PMM, this is a device made available in filesystem (OS) source. |
Overview
To create a MemoryChunk and Regions required, POST a MemoryChunk to the MemoryChunkCollection in a specific MemoryDomain. In the POST, list the DIMMs that should be included in MemorySet for the MemoryChunk, based on the InterleavableMemorySets
in the MemoryDomain. All DIMMs on the socket related to the MemoryDomain must be configured in a MemoryChunk in order for the configuration to succeed.
To delete a MemoryChunk, DELETE the MemoryChunk from the MemoryChunkCollection. Deleting a MemoryChunk will result in the corresponding memory region being set to volatile memory.
POST will only be supported for persistent Memory Chunks. Remaining capacity will be configured as volatile. Only persistent Memory Chunks will be reported in the system, since volatile interleaving is not reported for standard DIMMs.
Only one Interleaved MemoryChunk is supported, and that Interleaved MemoryChunk must include all DIMMs on that socket. This matches what is specified in the MemoryDomain’s InterleavableMemorySets
. If several POST requests are issued to configure multiple Interleaved MemoryChunks on a socket, iLO will reject the POST. iLO ensures all CPU installed PMMs are included in the memory set for a POST that is creating an interleaved Memory Chunk. This also checks for duplicate DIMM entries.
Memory Population Violations
If the memory population rules are violated, then configuration through the iLO RESTful API is not supported. Configuration may fail or have unexpected results.
MemoryChunk POST properties
AddressRangeType
: requiredMemoryChunkSizeMiB
: optional, default value is 0. Maximum is the sum total of the CapacityMiB of each Memory in theInterleaveSets
. Specify this orMemoryChunkSizePercentage
, but not both. In order to create the PMM goal configuration, sizes will be converted to a percentage. During this conversion, the size may change slightly.IsMirrorEnabled
: optional, default value is falseIsSpare
: optional, default is false.InterleaveSets
: required. Must match one of theInterleavableMemorySets
in the corresponding MemoryDomain. IfInterleaveSet
is empty, all possible Memory in the Memory Domain will be included in the Memory Chunk by default. BIOS will use best interleaving.Oem.Hpe.MemoryChunkSizePercentage
: optional, default value is 0. Specify this orMemoryChunkSizeMiB
, but not both.MemoryChunkSizePercentage
is recommended.
Note: The values specified by MemoryChunkSizeMiB
or MemoryChunkSizePercentage
must be the same across all POST requests on a given socket (Memory Domain).
Example MemoryChunk POST
The example below is a POST body for creating a MemoryChunk using the MemoryChunkSizePercentage
property. The PMMs on processor 1 in slots 6 and 7 will be interleaved and provisioned to 50% persistent memory (App Direct) mode. The remaining 50% is set to volatile (memory) mode.
POST /redfish/v1/Systems/1/MemoryDomains/PROC1MemoryDomain/MemoryChunks/
{
"AddressRangeType": "PMEM",
"Oem": {
"Hpe": {
"MemoryChunkSizePercentage": 50
}
},
"InterleaveSets": [
{
"Memory" : { "@odata.id": "/redfish/v1/Systems/1/Memory/proc1dimm6/"}
},
{
"Memory" : { "@odata.id": "/redfish/v1/Systems/1/Memory/proc1dimm7/"}
}
]
}
Configuration Tasks
Since the POST and DELETE modifications to the MemoryChunks are applied on system reboot, iLO will create a Task for each request. The Tasks are managed by the TaskService. On success, the POST and DELETE responses will include information about the corresponding Task. All the staged Tasks will be provided to BIOS on reboot. BIOS will process all the Tasks, in order, to create new Goal Configurations for each impacted PMMs. If Goal Configurations cannot be created, then ALL of the Tasks will fail, and the Task status will report the reason for the failure. PATCH to the MemoryChunk is not supported, so reconfiguration of existing configurations must first DELETE the existing MemoryChunks before creating a new configuration.
Example response to a MemoryChunk POST:
Status: 202 Accepted
{
"@odata.context": "/redfish/v1/$metadata#Task.Task",
"@odata.etag": "W/\"D793BCE6\"",
"@odata.id": "/redfish/v1/TaskService/Tasks/1545/",
"@odata.type": "#Task.v1_3_0.Task",
"Id": "1545",
"Description": "iLO Task",
"Messages": [
{}
],
"Name": "Task 1545",
"Payload": {
"HttpOperation": "POST",
"JsonBody": "{\"AddressRangeType\":\"PMEM\",\"InterleaveSets\":[{\"Memory\":{\"@odata.id\":\"/redfish/v1/Systems/1/Memory/proc1dimm6/\"}},{\"Memory\":{\"@odata.id\":\"/redfish/v1/Systems/1/Memory/proc1dimm7/\"}}],\"Oem\":{\"Hpe\":{\"MemoryChunkSizePercentage\":100}}}",
"TargetUri": "/redfish/v1/Systems/1/MemoryDomains/PROC1MemoryDomain/MemoryChunks/"
},
"StartTime": "2019-03-06T16:18:50Z",
"TaskMonitor": "/redfish/v1/TaskService/TaskMonitors/1545/",
"TaskState": "New"
}
POST and Task limits
iLO will limit the total number of Tasks to a minimum of 192.
Configuration Sequencing
The intent of configuration will only be inferred from the sequence in which the requests are made. As such, any DELETE requests must precede any POST requests relating to MemoryDomains on the same socket. A DELETE request and a POST request may be performed in the same reboot, as long as they follow this rule.
Example 1: Reconfigure to Change Interleaving
Start: Example configuration is two PMMs, A1 and A2, of 16 GiB each on a single socket on the same memory controller. There are two existing MemoryChunks, MC1 and MC2, for 100% persistent memory non-interleaved.
Goal: Reconfigure these two PMMs to be 100% persistent memory interleaved.
Solution: The client would first issue a DELETE request on MC1 and a separate DELETE request on MC2. This would create two New Tasks in the
TaskService. The client would then issue a POST request on the MemoryDomain’s Memory Chunk Collection. The POST body includes DIMMs A1 and A2 in the corresponding InterleaveSets
with an
Oem.Hpe.MemoryChunkSizePercentage
of 100% or a MemoryChunkSizeMiB
of 32GiB. This would result in three New Tasks in the TaskService queue to be consumed on
reboot. See details steps below:
- Delete MC1.
DELETE
/redfish/v1/Systems/1/MemoryDomains/PROC1MemoryDomain/MemoryChunks/MC1
- Delete MC2.
DELETE
/redfish/v1/Systems/1/MemoryDomains/PROC1MemoryDomain/MemoryChunks/MC2
- Create new configuration: Option 1 using MemoryChunkSizePercentage
POST
/redfish/v1/Systems/1/MemoryDomains/PROC1MemoryDomain/MemoryChunks
{
"AddressRangeType": "PMEM",
"Oem": {
"Hpe": {
"MemoryChunkSizePercentage": 100
}
},
"InterleaveSets": [
{
"Memory": {
"@odata.id": "/redfish/v1/Systems/1/Memory/A1/"
}
},
{
"Memory": {
"@odata.id": "/redfish/v1/Systems/1/Memory/A2/"
}
}
]
}
- Create new configuration: Option 2 using MemoryChunkSizeMiB
POST
/redfish/v1/Systems/1/MemoryDomains/PROC1MemoryDomain/MemoryChunks
{
"AddressRangeType": "PMEM",
"MemoryChunkSizeMiB": 32768,
"InterleaveSets": [
{
"Memory": {
"@odata.id": "/redfish/v1/Systems/1/Memory/A1/"
}
},
{
"Memory": {
"@odata.id": "/redfish/v1/Systems/1/Memory/A2/"
}
}
]
}
- Reboot system to apply changes staged in iLO as Tasks.
Example 2: Reconfigure to change Memory Provisioning on Two-Socket System
Start: Example configuration is two PMMs, A1 and A2, of 16GiB each on a single socket on the same memory controller. There are two existing MemoryChunks, MC1 and MC2, for 100% persistent memory non-interleaved. Also, two PMMs, B1 and B2, of 16GiB each on a single socket (separate than A1 and A2) on the same memory controller with two existing MemoryChunks, MC3 and MC4, for 100% persistent memory non-interleaved.
Goal: Reconfigure these four PMMs to be 50% persistent memory non-interleaved. The remaining 50% is volatile (memory mode).
Solution: The client would first issue separate DELETE requests on MC1, MC2, MC3, and MC4. This would create four New Tasks in the TaskService. The client would then issue a POST request on the Memory Chunk Collection of the MemoryDomain corresponding to A1 with A1 in the corresponding InterleaveSets
and an Oem.Hpe.MemoryChunkSizePercentage
of 50% or a MemoryChunkSizeMiB
of 16GiB. The client would repeat this POST request on the MemoryDomains corresponding to A2, B1, and B2 with each of those respective DIMMs in their own InterleaveSets
. This would result in eight New Tasks in the TaskService queue that would be consumed on reboot. See detailed steps below:
- Delete MC1.
DELETE
/redfish/v1/Systems/1/MemoryDomains/PROC1MemoryDomain/MemoryChunks/MC1
- Delete MC2.
DELETE
/redfish/v1/Systems/1/MemoryDomains/PROC1MemoryDomain/MemoryChunks/MC2
- Delete MC3.
DELETE
/redfish/v1/Systems/1/MemoryDomains/PROC2MemoryDomain/MemoryChunks/MC3
- Delete MC4.
DELETE
/redfish/v1/Systems/1/MemoryDomains/PROC2MemoryDomain/MemoryChunks/MC4
- Create new configuration using MemoryChunkSizePercentage for A1.
POST
/redfish/v1/Systems/1/MemoryDomains/PROC1MemoryDomain/MemoryChunks
{
"AddressRangeType": "PMEM",
"Oem": {
"Hpe": {
"MemoryChunkSizePercentage": 50
}
},
"InterleaveSets": [
{
"Memory": {
"@odata.id": "/redfish/v1/Systems/1/Memory/A1/"
}
}
]
}
- Create new configuration using MemoryChunkSizePercentage for A2.
POST
/redfish/v1/Systems/1/MemoryDomains/PROC1MemoryDomain/MemoryChunks
{
"AddressRangeType": "PMEM",
"Oem": {
"Hpe": {
"MemoryChunkSizePercentage": 50
}
},
"InterleaveSets": [
{
"Memory": {
"@odata.id": "/redfish/v1/Systems/1/Memory/A2/"
}
}
]
}
- Create new configuration using MemoryChunkSizePercentage for B1.
POST
/redfish/v1/Systems/1/MemoryDomains/PROC2MemoryDomain/MemoryChunks
{
"AddressRangeType": "PMEM",
"Oem": {
"Hpe": {
"MemoryChunkSizePercentage": 50
}
},
"InterleaveSets": [
{
"Memory": {
"@odata.id": "/redfish/v1/Systems/1/Memory/B1/"
}
}
]
}
- Create new configuration using MemoryChunkSizePercentage for B2.
POST
/redfish/v1/Systems/1/MemoryDomains/PROC2MemoryDomain/MemoryChunks
{
"AddressRangeType": "PMEM",
"Oem": {
"Hpe": {
"MemoryChunkSizePercentage": 50
}
},
"InterleaveSets": [
{
"Memory": {
"@odata.id": "/redfish/v1/Systems/1/Memory/B2/"
}
}
]
}
- Reboot system to apply changes staged in iLO as Tasks.
Managing Apollo Drive Bay Mapping
The HPE Apollo 2000 System with the HPE Apollo r2800 Chassis (including the Storage Expander Backplane) supports 24 SFF HPE SmartDrives. The SFF drive bays can be assigned to specific server nodes.
CAUTION: Changing the drive bay mapping configuration might cause data loss or data corruption. For example, consider a configuration with drive bays two through seven assigned to node 1, with the drives configured as a RAID0 volume. Data corruption might occur if you change the drive bay mapping so that the configured drives are no longer available.
Prerequisites
- HPE iLO 5 firmware 1.20 or later
- Storage enclosure processor firmware 1.00 or later
- Chassis firmware 1.2.10 or later
Getting host port topology details
The HostPortsInfo JSON object displays the node number and SAS controller associated with each server host port. Before you change the drive bay mapping, HPE recommends using the following REST API to view and understand the PortNumber mapping:
GET /redfish/v1/Chassis/1/AccHddService
This action returns the HostPortsInfo JSON object.
{
"HostPortsInfo": [
{
"NodeNumber": 1,
"PortNumber": 1,
"SlotNumber": 1
},
{
"NodeNumber": 2,
"PortNumber": 2,
"SlotNumber": 1
},
{
"NodeNumber": 3,
"PortNumber": 3,
"SlotNumber": 1
},
{
"NodeNumber": 4,
"PortNumber": 4,
"SlotNumber": 1
}
]
}
Getting current and pending drive bay mapping
GET /redfish/v1/Chassis/1/AccHddService/zone
This action returns the CurrentZoneConfiguration and PendingZoneConfiguration JSON objects.
The CurrentZoneConfiguration JSON object displays the current drive bay mapping in the chassis.
{
"CurrentZoneConfiguration": {
"HostPort": [
{
"BayNumber": [ 1, 2, 3, 4, 5, 6 ],
"PortNumber": 1
},
{
"BayNumber": [ 7, 8, 9, 10, 11, 12 ],
"PortNumber": 2
},
{
"BayNumber": [ 13, 14, 15, 16, 17, 18 ],
"PortNumber": 3
},
{
"BayNumber": [ 19, 20, 21, 22, 23, 24 ],
"PortNumber": 4
},
{
"PortNumber": null
}
]
}
}
Note: The value PortNumber null indicates that a drive bay is not assigned.
The PendingZoneConfiguration JSON object displays the pending drive bay mapping configuration. This configuration will not be applied until all nodes remain powered off for at least 5 seconds.
{
"PendingZoneConfiguration": {
"HostPort": [
{
"BayNumber": [ 1, 2, 3, 4 ],
"PortNumber": 1
},
{
"BayNumber": [ 7, 8, 9, 10 ],
"PortNumber": 2
},
{
"BayNumber": [ 13, 14, 15, 16 ],
"PortNumber": 3
},
{
"BayNumber": [ 19, 20, 21, 22 ],
"PortNumber": 4
},
{
"BayNumber": [ 5, 6, 11, 12, 17, 18, 23, 24 ],
"PortNumber": null
}
]
}
}
Note: The value PortNumber null indicates that a drive bay is not assigned.
Configuring drive bay mapping
You can make drive bay mapping configuration changes from any server node. The changes take effect when all server nodes in the Apollo 2000 system chassis are powered off and the Chassis firmware is able to reset the Storage Expander backplane. All nodes must remain powered off for at least 5 seconds after you initiate the configuration change.
The following example shows three drive bays assigned to each node.
POST /redfish/v1/Chassis/1/AccHddService/Zone/Actions/HpeServerAccHddZone.ConfigureZone
{
"HostPort": [
{
"BayNumber": [
1,
2,
3
],
"PortNumber": 1
},
{
"BayNumber": [
7,
8,
9
],
"PortNumber": 2
},
{
"BayNumber": [
13,
14,
15
],
"PortNumber": 3
},
{
"BayNumber": [
19,
20,
21
],
"PortNumber": 4
}
]
}
This action returns a response indicating that all server nodes in the chassis must remain powered off for at least 5 seconds for the changes to take effect.
{
"error": {
"code": "iLO.0.10.ExtendedInfo",
"message": "See @Message.ExtendedInfo for more information.",
"@Message.ExtendedInfo": [
{
"MessageId": "iLO.2.9.ChassisResetRequired"
}
]
}
}
Setting drive bay mapping to the default configuration
The default configuration divides the 24 SFF drive bays by the number of server host ports in the Apollo 2000 Chassis. In a configuration with four 1U servers, the default drive bay configuration is six drive bays allocated to each of the four server slots. In a configuration with two 2U servers, the default drive bay configuration is 12 drive bays allocated to each of the two server slots.
POST an empty JSON object to URI to set drive bay mapping to the default configuration.
POST /redfish/v1/Chassis/1/AccHddService/Zone/Actions/HpeServerAccHddZone.LoadDefault
{}
This action returns a response indicating that all server nodes in the chassis must remain powered off for at least 5 seconds for the changes to take effect.
{
"error": {
"code": "iLO.0.10.ExtendedInfo",
"message": "See @Message.ExtendedInfo for more information.",
"@Message.ExtendedInfo": [
{
"MessageId": "iLO.2.9.ChassisResetRequired"
}
]
}
}
Error messages and registries in the iLO RESTful API
HTTP response 400
{
"error": {
"@Message.ExtendedInfo": [
{
"MessageId": "iLO.0.9.InvalidLicenseKey"
}
],
"code": "iLO.0.10.ExtendedInfo",
"message": "See @Message.ExtendedInfo for more information."
}
}
"InvalidLicenseKey": {
"Description": "The license key is not valid.",
"Message": "The license key is not valid.",
"Severity": "Warning",
"NumberOfArgs": 0,
"ParamTypes": [],
"Resolution": "Retry the operation using a valid license key."
}
Error messages appear in several places in the iLO RESTful API.
- An immediate response to an HTTP operation.
- A
SettingsResult
in the data model where other providers, such as BIOS, processed the settings at some point and want to communicate status in the model.
All error cases use a basic error JSON structure called ExtendedInfo
. The most important property in ExtendedInfo
is MessageId
, a string containing a lookup key into a message registry.
MessageId
helps to keep the iLO service small by keeping much of the explanatory text for an error out of the code. Instead, iLO supplies an ExtendedInfo
response, where the MessageId
provides enough information so that you can look up more details from another file.
For example, if you POST
to the iLO license service to install an iLO license, but you supply an incorrect LicenseKey
string, iLO responds with an error similar to the following:
HTTP response 400 is the standard RESTful API response to an error. In the example above, the error is easy to understand, but some errors are not easy to understand. To display a more meaningful error message, parse the string iLO.0.9.InvalidLicenseKey
into the following
components:
iLO.0.9
—This is the base name of the message registry to consult. Look for a matching registry file.InvalidLicenseKey
—This is the lookup key into the message registry.
The search returns a result similar to the following:
Many error messages can also return parameters. These parameters may be plugged into the strings in the registry to form detailed messages tailored to the instance of the error message.
RESTful Events and the Event Service
iLO 6 features an event subscription service that enables you to subscribe to receive notifications when the REST data changes or when certain alerts occur. These notifications are in the form of HTTPS POST
operations to a URI of your choice.
The event service is located in the data model at /redfish/v1/EventService.
This resource includes a link to a collection of subscriptions (called Subscriptions
located at /redfish/v1/EventService/Subscriptions
).
Subscribing for Events examples
POST /redfish/v1/EventService/Subscriptions/
{
"Destination": "https://myeventreciever/eventreceiver",
"RegistryPrefixes": [
"StorageDevice",
"NetworkDevice",
"iLOEvents",
"ResourceEvent"
],
"HttpHeaders": {
"Header": "HeaderValue"
},
"Context": "context string",
"Oem": {
"Hpe": {
"DeliveryRetryIntervalInSeconds": 30,
"RequestedMaxEventsToQueue": 20,
"DeliveryRetryAttempts": 5,
"RetireOldEventInMinutes": 10
}
}
}
In order to receive events, you must provide an HTTPS server accessible to iLO’s network with a URI you designate as the target for iLO-initiated HTTPS POST operations.
Construct a JSON object conforming to the type ListenerDestination
(see example) and POST
this to the collection indicated by the Subscriptions
link at /redfish/v1/EventService/Subscriptions
. If you receive an HTTP 201 Created response, a new subscription has been added. Note that iLO does not test the destination URI during this phase, so if the indicated URI is not valid, this will not be flagged until events are emitted and the connection to the destination fails.
Example POST payload to create a new subscription
Much of the above content depends entirely upon your needs and setup:
Destination
must be an HTTPS URI accessible to iLO’s network.RegistryPrefixes
in the example is everything but you could remove registries from the array.HttpHeaders
gives you an opportunity to specify any arbitrary HTTP headers you need for the eventPOST
operation. Note that the subscription is readable viaGET
to an authorized iLO user.Context
may be any string.
Using the RESTful Interface Tool
Although not a requirement, you can use the RESTful Interface Tool with the RESTful API. This command line tool provides a level of abstraction and convenience above direct access to the RESTful API. For more information, see: http://www.hpe.com/info/resttool.
Client Best Practices
When developing a client for the RESTful API, be sure to not code based upon assumptions that are not guaranteed. The reason avoiding these assumptions is so important is that implementations may vary across systems and firmware versions, and we want your code to work consistently.
API Architecture
The RESTful API is a hypermedia API by design. This is to avoid building in restrictive assumptions to the data model that will make it difficult to adapt to future hardware implementations. A hypermedia API avoids these assumptions by making the data model discoverable via links between resources.
The client should not interact with a URI as if it will remain static. Only specific top-level URIs (any URI in this sample code) can be assumed as static.
All URIs, with the exception of known top-level URIs, must be discovered dynamically by following the href links in the data model. Clients should not make assumptions about the URIs for the resource members of a collection. For instance, the URI of a collection member will NOT always be /redfish/v1/.../collection/1
, or 2.
Traversing the data model
Although the resources in the data model are linked together, because of cross link references between resources, a client may not assume the resource model is a tree. It is a graph instead, so any crawl of the data model should keep track of visited resources to avoid an infinite traversal loop.
A reference to another resource is any property called href (@odata.id in Redfish) no matter where it occurs in a resource.
An external reference to a resource outside the data model is referred to by a property called extref
. Any resource referred to by extref
should not be assumed to follow the conventions of the API.
HTTP POST to Create
When POSTing to create a resource (e.g. create an account or session), a successful response includes a Location HTTP header indicating the resource URI of the newly created resource. The POST may also include a representation of the newly created object in a JSON response body but may not. Do not assume the response body, but test it. It may also be an ExtendedError object.
HTTP Redirect
All clients must correctly handle HTTP redirect (for example, 308, 301, and so on.). iLO 6 will use redirection as a way to alias portions of the data model and to migrate the data model to the Redfish specified URIs (for example, /redfish/…).
Other Web Resources
Redfish DMTF standard at http://www.dmtf.org/standards/redfish.
HPE RESTful API Home page: http://www.hpe.com/info/restfulapi.
Example Python code: https://github.com/HewlettPackard/python-ilorest-library.
Resource Map
URI | Type |
---|---|
/redfish/v1/ |
ServiceRoot |
/redfish/v1/AccountService |
AccountService |
/redfish/v1/AccountService/Accounts |
Collection of ManagerAccount |
/redfish/v1/AccountService/Accounts/{item} |
ManagerAccount |
/redfish/v1/AccountService/DirectoryTest |
HpeDirectoryTest |
/redfish/v1/AccountService/ExternalAccountProviders/LDAP/Certificates |
Collection of Certificate |
/redfish/v1/AccountService/ExternalAccountProviders/LDAP/Certificates/{item} |
Certificate |
/redfish/v1/AccountService/Roles |
Collection of Role |
/redfish/v1/AccountService/Roles/{item} |
Role |
/redfish/v1/AccountService/UserCertificateMapping |
Collection of HpeiLOAccountCertificateMap |
/redfish/v1/AccountService/UserCertificateMapping/{item} |
HpeiLOAccountCertificateMap |
/redfish/v1/CertificateService |
CertificateService |
/redfish/v1/CertificateService/CertificateLocations |
CertificateLocations |
/redfish/v1/Chassis |
Collection of Chassis |
/redfish/v1/Chassis/{item} |
Chassis |
/redfish/v1/Chassis/{item}/AccHddService |
HpeServerAccHddService |
/redfish/v1/Chassis/{item}/AccHddService/Zone |
HpeServerAccHddZone |
/redfish/v1/Chassis/{item}/Devices |
Collection of HpeServerDevice |
/redfish/v1/Chassis/{item}/Devices/{item} |
HpeServerDevice |
/redfish/v1/Chassis/{item}/NetworkAdapters |
Collection of NetworkAdapter |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item} |
NetworkAdapter |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/NetworkDeviceFunctions |
Collection of NetworkDeviceFunction |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/NetworkDeviceFunctions/{item} |
NetworkDeviceFunction |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/NetworkDeviceFunctions/{item}/Settings |
NetworkDeviceFunction |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/Ports |
Collection of Port |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/Ports/{item} |
Port |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/Ports/{item}/Settings |
Port |
/redfish/v1/Chassis/{item}/NetworkAdapters/{item}/Settings |
NetworkAdapter |
/redfish/v1/Chassis/{item}/Power |
Power |
/redfish/v1/Chassis/{item}/Power/AccPowerService |
HpeServerAccPowerService |
/redfish/v1/Chassis/{item}/Power/AccPowerService/Calibration |
HpeServerAccPowerCalibration |
/redfish/v1/Chassis/{item}/Power/AccPowerService/NodesInfo |
HpeServerAccPowerNodesInfo |
/redfish/v1/Chassis/{item}/Power/AccPowerService/PowerLimit |
HpeServerAccPowerLimit |
/redfish/v1/Chassis/{item}/Power/AccPowerService/Zone |
HpeServerAccPowerZone |
/redfish/v1/Chassis/{item}/Power/FastPowerMeter |
HpePowerMeter |
/redfish/v1/Chassis/{item}/Power/FederatedGroupCapping |
HpeiLOFederatedGroupCapping |
/redfish/v1/Chassis/{item}/Power/PowerMeter |
HpePowerMeter |
/redfish/v1/Chassis/{item}/Thermal |
Thermal |
/redfish/v1/ComponentIntegrity |
Collection of ComponentIntegrity |
/redfish/v1/ComponentIntegrity/{item} |
ComponentIntegrity |
/redfish/v1/EventService |
EventService |
/redfish/v1/EventService/CACertificates |
Collection of HpeCertificate |
/redfish/v1/EventService/CACertificates/{item} |
HpeCertificate |
/redfish/v1/EventService/Subscriptions |
Collection of EventDestination |
/redfish/v1/EventService/Subscriptions/{item} |
EventDestination |
/redfish/v1/JsonSchemas |
Collection of JsonSchemaFile |
/redfish/v1/JsonSchemas/{item} |
JsonSchemaFile |
/redfish/v1/Managers |
Collection of Manager |
/redfish/v1/Managers/{item} |
Manager |
/redfish/v1/Managers/{item}/ActiveHealthSystem |
HpeiLOActiveHealthSystem |
/redfish/v1/Managers/{item}/BackupRestoreService |
HpeiLOBackupRestoreService |
/redfish/v1/Managers/{item}/BackupRestoreService/BackupFiles |
Collection of HpeiLOBackupFile |
/redfish/v1/Managers/{item}/BackupRestoreService/BackupFiles/{item} |
HpeiLOBackupFile |
/redfish/v1/Managers/{item}/DateTime |
HpeiLODateTime |
/redfish/v1/Managers/{item}/EmbeddedMedia |
HpeiLOEmbeddedMedia |
/redfish/v1/Managers/{item}/EthernetInterfaces |
Collection of EthernetInterface |
/redfish/v1/Managers/{item}/EthernetInterfaces/{item} |
EthernetInterface |
/redfish/v1/Managers/{item}/FederationGroups |
Collection of HpeiLOFederationGroup |
/redfish/v1/Managers/{item}/FederationGroups/{item} |
HpeiLOFederationGroup |
/redfish/v1/Managers/{item}/FederationPeers |
Collection of HpeiLOFederationPeers |
/redfish/v1/Managers/{item}/FederationPeers/{item} |
HpeiLOFederationPeers |
/redfish/v1/Managers/{item}/HostInterfaces |
Collection of HostInterface |
/redfish/v1/Managers/{item}/HostInterfaces/{item} |
HostInterface |
/redfish/v1/Managers/{item}/LicenseService |
Collection of HpeiLOLicense |
/redfish/v1/Managers/{item}/LicenseService/{item} |
HpeiLOLicense |
/redfish/v1/Managers/{item}/LogServices |
Collection of LogService |
/redfish/v1/Managers/{item}/LogServices/IEL |
LogService |
/redfish/v1/Managers/{item}/LogServices/IEL/Entries |
Collection of LogEntry |
/redfish/v1/Managers/{item}/LogServices/IEL/Entries/{item} |
LogEntry |
/redfish/v1/Managers/{item}/NetworkProtocol |
ManagerNetworkProtocol |
/redfish/v1/Managers/{item}/RemoteSupportService |
HpeRemoteSupport |
/redfish/v1/Managers/{item}/RemoteSupportService/ServiceEventLogs |
Collection of LogEntry |
/redfish/v1/Managers/{item}/RemoteSupportService/ServiceEventLogs/{item} |
LogEntry |
/redfish/v1/Managers/{item}/SecurityService |
HpeSecurityService |
/redfish/v1/Managers/{item}/SecurityService/AutomaticCertificateEnrollment |
HpeAutomaticCertEnrollment |
/redfish/v1/Managers/{item}/SecurityService/CertificateAuthentication |
HpeCertAuth |
/redfish/v1/Managers/{item}/SecurityService/CertificateAuthentication/CACertificates |
Collection of HpeCertificate |
/redfish/v1/Managers/{item}/SecurityService/CertificateAuthentication/CACertificates/{item} |
HpeCertificate |
/redfish/v1/Managers/{item}/SecurityService/ESKM |
HpeESKM |
/redfish/v1/Managers/{item}/SecurityService/HttpsCert |
HpeHttpsCert |
/redfish/v1/Managers/{item}/SecurityService/PlatformCert/Certificates |
Collection of Certificate |
/redfish/v1/Managers/{item}/SecurityService/PlatformCert/Certificates/{item} |
Certificate |
/redfish/v1/Managers/{item}/SecurityService/SSO |
HpeiLOSSO |
/redfish/v1/Managers/{item}/SecurityService/SecurityDashboard |
HpeiLOSecurityDashboard |
/redfish/v1/Managers/{item}/SecurityService/SecurityDashboard/SecurityParams |
Collection of HpeiLOSecurityParam |
/redfish/v1/Managers/{item}/SecurityService/SecurityDashboard/SecurityParams/{item} |
HpeiLOSecurityParam |
/redfish/v1/Managers/{item}/SecurityService/SystemIAK/Certificates |
Collection of Certificate |
/redfish/v1/Managers/{item}/SecurityService/SystemIAK/Certificates/{item} |
Certificate |
/redfish/v1/Managers/{item}/SecurityService/SystemIDevID/Certificates |
Collection of Certificate |
/redfish/v1/Managers/{item}/SecurityService/SystemIDevID/Certificates/{item} |
Certificate |
/redfish/v1/Managers/{item}/SecurityService/iLOIDevID/Certificates |
Collection of Certificate |
/redfish/v1/Managers/{item}/SecurityService/iLOIDevID/Certificates/{item} |
Certificate |
/redfish/v1/Managers/{item}/SecurityService/iLOLDevID/Certificates |
Collection of Certificate |
/redfish/v1/Managers/{item}/SecurityService/iLOLDevID/Certificates/{item} |
Certificate |
/redfish/v1/Managers/{item}/SerialInterfaces |
Collection of SerialInterface |
/redfish/v1/Managers/{item}/SerialInterfaces/{item} |
SerialInterface |
/redfish/v1/Managers/{item}/SnmpService |
HpeiLOSnmpService |
/redfish/v1/Managers/{item}/SnmpService/SNMPAlertDestinations |
Collection of HpeSNMPAlertDestination |
/redfish/v1/Managers/{item}/SnmpService/SNMPAlertDestinations/{item} |
HpeSNMPAlertDestination |
/redfish/v1/Managers/{item}/SnmpService/SNMPUsers |
Collection of HpeSNMPUser |
/redfish/v1/Managers/{item}/SnmpService/SNMPUsers/{item} |
HpeSNMPUser |
/redfish/v1/Managers/{item}/VirtualMedia |
Collection of VirtualMedia |
/redfish/v1/Managers/{item}/VirtualMedia/{item} |
VirtualMedia |
/redfish/v1/Registries |
Collection of MessageRegistryFile |
/redfish/v1/Registries/{item} |
MessageRegistryFile |
/redfish/v1/ResourceDirectory |
HpeiLOResourceDirectory |
/redfish/v1/SessionService |
SessionService |
/redfish/v1/SessionService/Sessions |
Collection of Session |
/redfish/v1/SessionService/Sessions/{item} |
Session |
/redfish/v1/Systems |
Collection of ComputerSystem |
/redfish/v1/Systems/{item} |
ComputerSystem |
/redfish/v1/Systems/{item}/Bios |
Bios |
/redfish/v1/Systems/{item}/Bios/Kmsconfig/Baseconfigs |
HpeBaseConfigs |
/redfish/v1/Systems/{item}/Bios/Kmsconfig/Settings |
HpeKmsConfig |
/redfish/v1/Systems/{item}/Bios/Serverconfiglock/Baseconfigs |
HpeBaseConfigs |
/redfish/v1/Systems/{item}/Bios/Serverconfiglock/Settings |
HpeServerConfigLock |
/redfish/v1/Systems/{item}/Bios/Settings |
Bios |
/redfish/v1/Systems/{item}/Bios/baseconfigs |
HpeBaseConfigs |
/redfish/v1/Systems/{item}/Bios/boot |
HpeServerBootSettings |
/redfish/v1/Systems/{item}/Bios/boot/Settings |
HpeServerBootSettings |
/redfish/v1/Systems/{item}/Bios/boot/baseconfigs |
HpeBaseConfigs |
/redfish/v1/Systems/{item}/Bios/iscsi |
HpeiSCSISoftwareInitiator |
/redfish/v1/Systems/{item}/Bios/iscsi/Settings |
HpeiSCSISoftwareInitiator |
/redfish/v1/Systems/{item}/Bios/iscsi/baseconfigs |
HpeBaseConfigs |
/redfish/v1/Systems/{item}/Bios/mappings |
HpeBiosMapping |
/redfish/v1/Systems/{item}/Bios/tlsconfig |
HpeTlsConfig |
/redfish/v1/Systems/{item}/Bios/tlsconfig/Settings |
HpeTlsConfig |
/redfish/v1/Systems/{item}/Bios/tlsconfig/baseconfigs |
HpeBaseConfigs |
/redfish/v1/Systems/{item}/BootOptions |
Collection of BootOption |
/redfish/v1/Systems/{item}/BootOptions/{item} |
BootOption |
/redfish/v1/Systems/{item}/EthernetInterfaces |
Collection of EthernetInterface |
/redfish/v1/Systems/{item}/EthernetInterfaces/{item} |
EthernetInterface |
/redfish/v1/Systems/{item}/LogServices |
Collection of LogService |
/redfish/v1/Systems/{item}/LogServices/DPU |
LogService |
/redfish/v1/Systems/{item}/LogServices/DPU/Entries |
Collection of LogEntry |
/redfish/v1/Systems/{item}/LogServices/DPU/Entries/{item} |
LogEntry |
/redfish/v1/Systems/{item}/LogServices/Event |
LogService |
/redfish/v1/Systems/{item}/LogServices/Event/Entries |
Collection of LogEntry |
/redfish/v1/Systems/{item}/LogServices/Event/Entries/{item} |
LogEntry |
/redfish/v1/Systems/{item}/LogServices/IML |
LogService |
/redfish/v1/Systems/{item}/LogServices/IML/Entries |
Collection of LogEntry |
/redfish/v1/Systems/{item}/LogServices/IML/Entries/{item} |
LogEntry |
/redfish/v1/Systems/{item}/LogServices/SL |
LogService |
/redfish/v1/Systems/{item}/LogServices/SL/Entries |
Collection of LogEntry |
/redfish/v1/Systems/{item}/LogServices/SL/Entries/{item} |
LogEntry |
/redfish/v1/Systems/{item}/Memory |
Collection of Memory |
/redfish/v1/Systems/{item}/Memory/{item} |
Memory |
/redfish/v1/Systems/{item}/MemoryDomains |
Collection of MemoryDomain |
/redfish/v1/Systems/{item}/MemoryDomains/{item} |
MemoryDomain |
/redfish/v1/Systems/{item}/MemoryDomains/{item}/MemoryChunks |
Collection of MemoryChunks |
/redfish/v1/Systems/{item}/MemoryDomains/{item}/MemoryChunks/{item} |
MemoryChunks |
/redfish/v1/Systems/{item}/NetworkInterfaces |
Collection of NetworkInterface |
/redfish/v1/Systems/{item}/NetworkInterfaces/{item} |
NetworkInterface |
/redfish/v1/Systems/{item}/NetworkInterfaces/{item}/NetworkDeviceFunctions |
Collection of NetworkDeviceFunction |
/redfish/v1/Systems/{item}/NetworkInterfaces/{item}/NetworkDeviceFunctions/{item} |
NetworkDeviceFunction |
/redfish/v1/Systems/{item}/NetworkInterfaces/{item}/Ports |
Collection of Port |
/redfish/v1/Systems/{item}/NetworkInterfaces/{item}/Ports/{item} |
Port |
/redfish/v1/Systems/{item}/NetworkInterfaces/{item}/Ports/{item}/Settings |
Port |
/redfish/v1/Systems/{item}/PCIDevices |
Collection of HpeServerPciDevice |
/redfish/v1/Systems/{item}/PCIDevices/{item} |
HpeServerPciDevice |
/redfish/v1/Systems/{item}/PCISlots |
Collection of HpeServerPCISlot |
/redfish/v1/Systems/{item}/PCISlots/{item} |
HpeServerPCISlot |
/redfish/v1/Systems/{item}/Processors |
Collection of Processor |
/redfish/v1/Systems/{item}/Processors/{item} |
Processor |
/redfish/v1/Systems/{item}/SecureBoot |
SecureBoot |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases |
Collection of SecureBootDatabase |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/KEK |
SecureBootDatabase |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/KEK/Certificates |
Collection of Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/KEK/Certificates/{item} |
Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/KEKDefault |
SecureBootDatabase |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/KEKDefault/Certificates |
Collection of Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/KEKDefault/Certificates/{item} |
Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/PK |
SecureBootDatabase |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/PK/Certificates |
Collection of Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/PK/Certificates/{item} |
Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/PKDefault |
SecureBootDatabase |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/PKDefault/Certificates |
Collection of Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/PKDefault/Certificates/{item} |
Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/db |
SecureBootDatabase |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/db/Certificates |
Collection of Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/db/Certificates/{item} |
Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/db/Signatures |
Collection of Signature |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/db/Signatures/{item} |
Signature |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbDefault/Certificates |
Collection of Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbDefault/Signatures |
Collection of Signature |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbDefault/Signatures/{item} |
Signature |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbr |
SecureBootDatabase |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbr/Certificates |
Collection of Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbr/Certificates/{item} |
Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbr/Signatures |
Collection of Signature |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbr/Signatures/{item} |
Signature |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbrDefault |
SecureBootDatabase |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbrDefault/Certificates |
Collection of Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbrDefault/Certificates/{item} |
Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbrDefault/Signatures |
Collection of Signature |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbrDefault/Signatures/{item} |
Signature |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbt |
SecureBootDatabase |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbt/Certificates |
Collection of Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbt/Certificates/{item} |
Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbt/Signatures |
Collection of Signature |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbt/Signatures/{item} |
Signature |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbtDefault |
SecureBootDatabase |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbtDefault/Certificates |
Collection of Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbtDefault/Certificates/{item} |
Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbtDefault/Signatures |
Collection of Signature |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbtDefault/Signatures/{item} |
Signature |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbx |
SecureBootDatabase |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbx/Certificates |
Collection of Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbx/Certificates/{item} |
Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbx/Signatures |
Collection of Signature |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbx/Signatures/{item} |
Signature |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbxDefault |
SecureBootDatabase |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbxDefault/Certificates |
Collection of Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbxDefault/Certificates/{item} |
Certificate |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbxDefault/Signatures |
Collection of Signature |
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/dbxDefault/Signatures/{item} |
Signature |
/redfish/v1/Systems/{item}/Storage |
Collection of Storage |
/redfish/v1/Systems/{item}/Storage/{item}/Controllers/ |
Collection of StorageController |
/redfish/v1/Systems/{item}/Storage/{item}/Controllers/{item} |
StorageController |
/redfish/v1/Systems/{item}/Storage/{item}/Controllers/{item}/Ports/{item} |
Port |
/redfish/v1/Systems/{item}/Storage/{item}/StorageControllers/{item}/Ports/{item} |
Port |
/redfish/v1/Systems/{item}/USBDevices |
Collection of HpeUSBDevice |
/redfish/v1/Systems/{item}/USBDevices/{item} |
HpeUSBDevice |
/redfish/v1/Systems/{item}/USBPorts |
Collection of HpeUSBPort |
/redfish/v1/Systems/{item}/USBPorts/{item} |
HpeUSBPort |
/redfish/v1/Systems/{item}/WorkloadPerformanceAdvisor |
Collection of HpeWorkloadPerformanceAdvisor |
/redfish/v1/Systems/{item}/WorkloadPerformanceAdvisor/{item} |
HpeWorkloadPerformanceAdvisor |
/redfish/v1/TaskService |
TaskService |
/redfish/v1/TaskService/Tasks |
Collection of Task |
/redfish/v1/TaskService/Tasks/{item} |
Task |
/redfish/v1/TelemetryService |
TelemetryService |
/redfish/v1/TelemetryService/MetricDefinitions |
Collection of MetricDefinition |
/redfish/v1/TelemetryService/MetricDefinitions/{item} |
MetricDefinition |
/redfish/v1/TelemetryService/MetricReportDefinitions |
Collection of MetricReportDefinition |
/redfish/v1/TelemetryService/MetricReportDefinitions/{item} |
MetricReportDefinition |
/redfish/v1/TelemetryService/MetricReports/{item} |
MetricReport |
/redfish/v1/TelemetryService/MetricsReport |
Collection of MetricReport |
/redfish/v1/TelemetryService/Triggers |
Collection of Triggers |
/redfish/v1/TelemetryService/Triggers/{item} |
Triggers |
/redfish/v1/UpdateService |
UpdateService |
/redfish/v1/UpdateService/ComponentRepository |
Collection of HpeComponent |
/redfish/v1/UpdateService/ComponentRepository/{item} |
HpeComponent |
/redfish/v1/UpdateService/FirmwareInventory |
Collection of SoftwareInventory |
/redfish/v1/UpdateService/FirmwareInventory/{item} |
SoftwareInventory |
/redfish/v1/UpdateService/InstallSets |
Collection of HpeComponentInstallSet |
/redfish/v1/UpdateService/InstallSets/{item} |
HpeComponentInstallSet |
/redfish/v1/UpdateService/InvalidImageRepository |
Collection of HpeInvalidImage |
/redfish/v1/UpdateService/InvalidImageRepository/{item} |
HpeInvalidImage |
/redfish/v1/UpdateService/MaintenanceWindows |
Collection of HpeMaintenanceWindow |
/redfish/v1/UpdateService/MaintenanceWindows/{item} |
HpeMaintenanceWindow |
/redfish/v1/UpdateService/SoftwareInventory |
Collection of SoftwareInventory |
/redfish/v1/UpdateService/SoftwareInventory/{item} |
SoftwareInventory |
/redfish/v1/UpdateService/UpdateTaskQueue |
Collection of HpeComponentUpdateTask |
/redfish/v1/UpdateService/UpdateTaskQueue/{item} |
HpeComponentUpdateTask |
/redfish/v1/systems/{item}/bios/Kmsconfig |
HpeKmsConfig |
/redfish/v1/systems/{item}/bios/Serverconfiglock |
HpeServerConfigLock |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbdefault |
SecureBootDatabase |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbdefault/certificates/{item} |
Certificate |
redfish/v1/Chassis/{item}/BaseFrus |
Collection of HpeiLOFrus |
redfish/v1/Chassis/{item}/BaseFrus/{item} |
HpeiLOFrus |
redfish/v1/Chassis/{item}/BaseFrus/{item}/Details |
HpeiLOFrus |
redfish/v1/Chassis/{item}/MezzFrus |
Collection of HpeiLOFrus |
redfish/v1/Chassis/{item}/MezzFrus/{item} |
HpeiLOFrus |
redfish/v1/Chassis/{item}/MezzFrus/{item}/Details |
HpeiLOFrus |
redfish/v1/Chassis/{item}/PCIeDevices |
Collection of PCIeDevice |
redfish/v1/Chassis/{item}/PCIeDevices/{item} |
PCIeDevice |
redfish/v1/Chassis/{item}/PCIeDevices/{item}/PCIeFunctions |
Collection of PCIeFunction |
redfish/v1/Chassis/{item}/PCIeDevices/{item}/PCIeFunctions/{item} |
PCIeFunction |
redfish/v1/Chassis/{item}/PCIeSlots |
PCIeSlots |
redfish/v1/Systems/{item}/NetworkInterfaces/{item}/NetworkDeviceFunctions/{item}/Settings |
NetworkDeviceFunction |
redfish/v1/Systems/{item}/SecureEraseReportService |
HpeSecureEraseReportService |
redfish/v1/Systems/{item}/SecureEraseReportService/SecureEraseReportEntries |
Collection of HpeSecureEraseReport |
redfish/v1/Systems/{item}/SecureEraseReportService/SecureEraseReportEntries/{item} |
HpeSecureEraseReport |
redfish/v1/Systems/{item}/Storage/{item} |
Storage |
redfish/v1/Systems/{item}/Storage/{item}/Drives/{item} |
Drive |
redfish/v1/Systems/{item}/Storage/{item}/Volumes |
Collection of Volume |
redfish/v1/Systems/{item}/Storage/{item}/Volumes/{item} |
Volume |
Resource Definitions
Each resource in the API has a type
that defines its properties. See the Redfish specification for @odata.type
for details.
This section defines the supported types and lists the typical instances of each. Because this API document is applicable to all HPE servers using iLO 6, you may find variations such as:
- properties implemented on one type of server and not another
- resources that are read only on one type of server and not another
- the number of resources of a particular type (for example, multiple compute nodes or enclosing chassis)
Collections
Many resource types in the API are members of collections
. Collections
are groups of similar resources and are typically an array of Member links.
Redfish does not define a generic collection type
(@odata.type
) but all collections are identical in structure. A ComputerSystemCollection
is identical in structure to a ChassisCollection
although they have slightly different names. Typically, collection types are suffixed with the word collection and are recognizable by the presence of the Members
array of links.
Collections may be GET-only that may not be added to or removed from. Examples of GET-only collections are the Systems collection at /redfish/v1/systems/
. In a typical systems collection describing physical hardware, it wouldn’t make sense to be able to create or remove members using GET or DELETE.
Other collections may be editable. Examples of these might be the Accounts collection at /redfish/v1/accountservice/accounts
. The API supports the addition or removal of user accounts. To add a new member to an editable collection, perform an HTTP POST to the collection resource with a body consisting of the required JSON properties needed to create a new member (this does not necessarily require you to POST every property because many may take a unique service-assigned value or take a default value.)
For more information on collections
, see the Redfish 1.0 DMTF standard at https://www.dmtf.org/standards/redfish and the example Python code: https://github.com/HewlettPackard/python-ilorest-library.
GET https://{iLO}/redfish/v1/systems/ showing a collection response (JSON)
{
"@odata.id": "/redfish/v1/systems/",
"@odata.context": "/redfish/v1/$metadata/",
"@odata.type": "#ComputerSystemCollection.ComputerSystemCollection",
"Members@odata.count": 1,
"Members": [
{
"@odata.id": "/redfish/v1/systems/1/"
}
]
}
Properties
Collection Instances:
https://{iLO}/redfish/v1/AccountService/Accounts
https://{iLO}/redfish/v1/Chassis
https://{iLO}/redfish/v1/EventService/EventSubscriptions
https://{iLO}/redfish/v1/Managers
https://{iLO}/redfish/v1/Managers/{item}/EthernetInterfaces
https://{iLO}/redfish/v1/Managers/{item}/FederationGroups
https://{iLO}/redfish/v1/Managers/{item}/FederationPeers
https://{iLO}/redfish/v1/Managers/{item}/LicenseService
https://{iLO}/redfish/v1/Managers/{item}/LogServices
https://{iLO}/redfish/v1/Managers/{item}/LogServices/IEL/Entries
https://{iLO}/redfish/v1/Managers/{item}/VirtualMedia
https://{iLO}/redfish/v1/Registries
https://{iLO}/redfish/v1/Schemas
https://{iLO}/redfish/v1/SessionService/Sessions
https://{iLO}/redfish/v1/Systems
https://{iLO}/redfish/v1/Systems/{item}/LogServices
https://{iLO}/redfish/v1/Systems/{item}/LogServices/IML/Entries
https://{iLO}/redfish/v1/Systems/{item}/Memory
https://{iLO}/redfish/v1/Systems/{item}/NetworkAdapters
https://{iLO}/redfish/v1/Systems/{item}/PCIDevices
https://{iLO}/redfish/v1/Systems/{item}/PCISlots
https://{iLO}/redfish/v1/Systems/{item}/SmartStorage/ArrayControllers
https://{iLO}/redfish/v1/Systems/{item}/SmartStorage/ArrayControllers/{item}/DiskDrives
https://{iLO}/redfish/v1/Systems/{item}/SmartStorage/ArrayControllers/{item}/LogicalDrives
https://{iLO}/redfish/v1/Systems/{item}/SmartStorage/ArrayControllers/{item}/StorageEnclosures
https://{iLO}/redfish/v1/Systems/{item}/SmartStorage/HostBusAdapters
Members@odata.count
JSONPath: /Members@odata.count
(read only integer)
The number of members in the collection.
Members[]
JSONPath: /Members
(read only array of links)
The Members array consists of links (@odata.id
) to the members of the collection.
AccountService.v1_5_0.AccountService
@odata.type: "#AccountService.v1_5_0.AccountService"
The AccountService resource describes the BMC user account management service. It represents the properties for this service and has links to the list of accounts.
Managing User Accounts with the Accounts Collection
JSONPath: /Accounts/@odata.id
The destination of this link is a collection of user accounts (see ManagerAccount).
- You may create a new user account by POSTing a new account description the the Accounts collection. See ManagerAccount for details.
> e.g.
POST https://{iLO}/redfish/v1/accountservice/accounts/ with new account description
- You may modify an existing user by PATCHing properties to the user account resource. See ManagerAccount for details.
> e.g.
PATCH https://{iLO}/redfish/v1/accountservice/accounts/{item} with different properties
- You may remove a user account by DELETEing the resources representing the user
> e.g.
DELETE https://{iLO}/redfish/v1/accountservice/accounts/{item}
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice |
GET POST PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Accounts |
Collection of ManagerAccount |
AccountLockoutCounterResetAfter
Member of AccountService.v1_5_0.AccountService
Description | The interval of time in seconds between the last failed login attempt and reset of the lockout threshold counter. This value must be less than or equal to AccountLockoutDuration. Reset sets the counter to zero. |
Type | number |
Read Only | True |
Added | iLO6 1.05 |
AccountLockoutCounterResetEnabled
Member of AccountService.v1_5_0.AccountService
Description | The value indicates whether the threshold counter will be reset after AccountLockoutCounterResetAfter expires. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
AccountLockoutDuration
Member of AccountService.v1_5_0.AccountService
Description | The time in seconds an account is locked out. The value must be greater than or equal to the value of the AccountLockoutCounterResetAfter property. If set to 0, no lockout occurs. |
Type | number or null |
Read Only | False |
Added | iLO6 1.05 |
AccountLockoutThreshold
Member of AccountService.v1_5_0.AccountService
Description | The number of failed login attempts allowed before a user account is locked for a specified duration. A value of 0 means it is never locked. |
Type | number or null |
Read Only | False |
Added | iLO6 1.05 |
Accounts
This property references a resource of type Collection with a MemberType of ManagerAccount.
Accounts is a link ("@odata.id": URI
) to another resource.
ActiveDirectory
ActiveDirectory.AccountProviderType Member of AccountService.v1_5_0.AccountService
Description | This property contains the type of external account provider this resource references. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ActiveDirectoryService |
An external Active Directory Service. |
ActiveDirectory.Authentication ActiveDirectory.Authentication.AuthenticationType Member of AccountService.v1_5_0.AccountService
Description | This property contains the type of authentication used to connect to the external account provider. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
UsernameAndPassword |
Username and password combination. |
ActiveDirectory.Authentication.Password Member of AccountService.v1_5_0.AccountService
Description | This property is used with a PATCH or PUT to write the password for the account service. This property is null on a GET. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
ActiveDirectory.Authentication.Username Member of AccountService.v1_5_0.AccountService
Description | This property contains the distinguished name for the account service. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
ActiveDirectory.RemoteRoleMapping (array)
Member of AccountService.v1_5_0.AccountService
RemoteRoleMapping
is an array containing elements of:
RemoteRoleMapping[{item}].LocalRole Member of AccountService.v1_5_0.AccountService
Description | The name of the local role in which to map the remote user or group. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
RemoteRoleMapping[{item}].RemoteGroup Member of AccountService.v1_5_0.AccountService
Description | This property is the name of the remote group (or in the case of a Redfish Service, remote role) that will be mapped to the local role referenced by this entity. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
ActiveDirectory.ServiceAddresses (array)
Member of AccountService.v1_5_0.AccountService
ServiceAddresses
is an array containing elements of:
ServiceAddresses[{item}] Member of AccountService.v1_5_0.AccountService
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ActiveDirectory.ServiceEnabled Member of AccountService.v1_5_0.AccountService
Description | This indicates whether this service is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
AuthFailureLoggingThreshold
Member of AccountService.v1_5_0.AccountService
Description | The number of authorization failures allowed before the failure attempt is logged to the manager log. |
Type | number |
Read Only | False |
Added | iLO6 1.05 |
LDAP
LDAP.AccountProviderType Member of AccountService.v1_5_0.AccountService
Description | This property contains the type of external account provider this resource references. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ActiveDirectoryService |
An external Active Directory Service. |
LDAPService |
A generic external LDAP Service. |
LDAP.Authentication LDAP.Authentication.AuthenticationType Member of AccountService.v1_5_0.AccountService
Description | This property contains the type of authentication used to connect to the external account provider. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
UsernameAndPassword |
Username and password combination. |
LDAP.Authentication.Password Member of AccountService.v1_5_0.AccountService
Description | This property is used with a PATCH or PUT to write the password for the account service. This property is null on a GET. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
LDAP.Authentication.Username Member of AccountService.v1_5_0.AccountService
Description | This property contains the distinguished name for the account service. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
LDAP.Certificates
A link to a collection of Certificates used for the external account service.
Certificates is a link ("@odata.id": URI
) to another resource.
LDAP.LDAPService
LDAP.LDAPService.SearchSettings
LDAP.LDAPService.SearchSettings.BaseDistinguishedNames (array)
Member of AccountService.v1_5_0.AccountService
BaseDistinguishedNames
is an array containing elements of:
BaseDistinguishedNames[{item}] Member of AccountService.v1_5_0.AccountService
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
LDAP.RemoteRoleMapping (array)
Member of AccountService.v1_5_0.AccountService
RemoteRoleMapping
is an array containing elements of:
RemoteRoleMapping[{item}].LocalRole Member of AccountService.v1_5_0.AccountService
Description | The name of the local role in which to map the remote user or group. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
RemoteRoleMapping[{item}].RemoteGroup Member of AccountService.v1_5_0.AccountService
Description | This property is the name of the remote group (or in the case of a Redfish Service, remote role) that will be mapped to the local role referenced by this entity. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
LDAP.ServiceAddresses (array)
Member of AccountService.v1_5_0.AccountService
ServiceAddresses
is an array containing elements of:
ServiceAddresses[{item}] Member of AccountService.v1_5_0.AccountService
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
LDAP.ServiceEnabled Member of AccountService.v1_5_0.AccountService
Description | This indicates whether this service is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
LocalAccountAuth
Member of AccountService.v1_5_0.AccountService
Description | Controls when this service will use the accounts defined withing this AccountService as part of authentication. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Authentication via accounts defined in this AccountService is enabled. |
Disabled |
Authentication via accounts defined in this AccountService is disabled. |
MaxPasswordLength
Member of AccountService.v1_5_0.AccountService
Description | The maximum password length for this service. |
Type | number |
Read Only | True |
Added | iLO6 1.05 |
MinPasswordLength
Member of AccountService.v1_5_0.AccountService
Description | The minimum password length for this account service. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.AuthFailureDelayTimeSeconds
Member of AccountService.v1_5_0.AccountService
Description | The time in seconds to delay for each failure after AuthFailuresBeforeDelay authentication attempts have failed. Values of 2, 5, 10, and 30 seconds are valid. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
2 |
5 |
10 |
30 |
Oem.Hpe.AuthFailureLoggingThreshold
Member of AccountService.v1_5_0.AccountService
Description | This property enables you to view and configure logging criteria for failed authentications. A failed login log entry is recorded after the configured number of attempts. 0 = feature disabled; 1-3 and 5 are allowable values. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Null |
1 |
2 |
3 |
5 |
Oem.Hpe.AuthFailuresBeforeDelay
Member of AccountService.v1_5_0.AccountService
Description | The number of failed authentication attempts allowed before authentication is delayed by AuthFailureDelayTimeSeconds. Values of 0, 1, 3, and 5 are valid, with 0 indicating delay after every authentication failure. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Null |
1 |
3 |
5 |
Oem.Hpe.DefaultPassword
Member of AccountService.v1_5_0.AccountService
Description | The default password used to log in to the management processor when factory reset is performed. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DefaultUserName
Member of AccountService.v1_5_0.AccountService
Description | The default name used to log in to the management processor when factory reset is performed. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DirectorySettings
Oem.Hpe.DirectorySettings.LdapAuthenticationMode Member of AccountService.v1_5_0.AccountService
Description | Represents the LDAP authentication mode. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Directory authentication is disabled. |
DefaultSchema |
Directory Default schema or Schema-free option is selected. |
ExtendedSchema |
HPE Extended schema is selected. |
Oem.Hpe.DirectorySettings.LdapCaCertificateLoaded Member of AccountService.v1_5_0.AccountService
Description | Represents if the directory server CA certificate is loaded or not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DirectorySettings.LdapCaCertificates
A link to a collection of Certificates.
LdapCaCertificates is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.DirectorySettings.LdapServerPort Member of AccountService.v1_5_0.AccountService
Description | Represents the port number of the directory server. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DirectoryTest
The value of this property shall be a reference to a resource of type HpeDirectoryTest.
DirectoryTest is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.EnforcePasswordComplexity
Member of AccountService.v1_5_0.AccountService
Description | Enforce complexity rules when a user password is set or changed. Three of four character classes must be present; ASCII UPPERCASE, LOWERCASE, DIGITS, and Other |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.KerberosSettings
Oem.Hpe.KerberosSettings.KDCServerPort Member of AccountService.v1_5_0.AccountService
Description | Represents the port number of the KDC server. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.KerberosSettings.KerberosRealm Member of AccountService.v1_5_0.AccountService
Description | Represents the Realm of the KDC server. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.MinPasswordLength
Member of AccountService.v1_5_0.AccountService
Description | This property specifies the minimum number of characters allowed when a user password is set or changed. It must be a value from 0 to 39. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.TwoFactorAuth
Member of AccountService.v1_5_0.AccountService
Description | This property indicates two factor authentication enabled or not |
Type | string |
Read Only | False |
Added | iLO6 1.50 |
The following are the supported values:
Value |
---|
Enabled |
Disabled |
Roles
A link to a collection of Roles.
Roles is a link ("@odata.id": URI
) to another resource.
Actions
HpeiLOAccountService.ImportKerberosKeytab Member of AccountService.v1_5_0.AccountService Import the Kerberos keytab file.
Parameters:
ImportUri (string)
URI of the kerberos keytab file.
Bios.v1_0_5.Bios
@odata.type: "#Bios.v1_0_5.Bios"
The Bios schema contains properties related to the BIOS Attribute Registry. The Attribute Registry describes the system-specific BIOS attributes and Actions for changing to BIOS settings. Changes to the BIOS typically require a system reset before they take effect. It is likely that a client will find the @Redfish.Settings term in this resource, and if it is found, the client makes requests to change BIOS settings by modifying the resource identified by the @Redfish.Settings term.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bios |
GET |
/redfish/v1/systems/{item}/bios/settings |
GET POST PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Oem/Hpe/Links/Boot |
HpeServerBootSettings |
@Redfish.Settings/SettingsObject |
Bios |
Oem/Hpe/Links/TlsConfig |
HpeTlsConfig |
Oem/Hpe/Links/BaseConfigs |
HpeBaseConfigs |
Oem/Hpe/Links/Mappings |
HpeBiosMapping |
Oem/Hpe/Links/iScsi |
HpeiSCSISoftwareInitiator |
@Redfish.Settings
Member of Bios.v1_0_5.Bios See the Redfish standard schema and specification for information on common @Redfish properties.
AttributeRegistry
Member of Bios.v1_0_5.Bios
Description | The Resource ID of the Attribute Registry that has the system-specific information about a BIOS resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Attributes
AMDPerformanceWorkloadProfile (AMD Performance Workload Profile) Member of Bios.v1_0_5.Bios
Description | Provide feature sets for specific performance requirement. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
CPUIntensive |
CPU Intensive |
JavaThroughput |
Java Throughput |
JavaLatency |
Java Latency |
PowerEfficiency |
Power Efficiency |
MemoryThroughputIntensive |
Memory Throughput Intensive |
StorageIOIntensive |
Storage IO Intensive |
NICThroughputIntensive |
NIC Throughput Intensive |
NICLatencySensitive |
NIC Latency Sensitive |
VMwareVSphereOptimized |
VMware vSphere Optimized |
LinuxKVMOptimized |
Linux KVM Optimized |
ContainerOptimized |
Container Optimized |
RDBMSOptimized |
RDBMS Optimized |
BigDataAnalyticsOptimized |
Big Data Analytics Optimized |
IOTGateway |
IOT Gateway |
HPCOptimized |
HPC Optimized |
OpenStackNFV |
OpenStack NFV |
OpenStackForRealTimeKernel |
OpenStack for RealTime Kernel |
AccessControlService (Access Control Service) Member of Bios.v1_0_5.Bios
Description | If enabled, Access Control Service is enabled for the downstream port. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AcpiHpet (High Precision Event Timer (HPET) ACPI Support) Member of Bios.v1_0_5.Bios
Description | Use this option to disable the High Precision Event Timer (HPET) table and device object in ACPI. When disabled, the HPET is not available to an operating system that supports the HPET through the industry standard ACPI name space. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AcpiRootBridgePxm (Memory Proximity Reporting for I/O) Member of Bios.v1_0_5.Bios
Description | When enabled, the System BIOS reports the proximity relationship between I/O devices and system memory to the operating system. Most operating systems can use this information to efficiently assign memory resources for devices, such as network controllers and storage devices. Additionally, certain I/O devices might not be able to take advantage of I/O handling benefits if their OS drivers are not properly optimized to support this feature. See your operating system and I/O device documentation for more details. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AcpiSlit (ACPI SLIT) Member of Bios.v1_0_5.Bios
Description | The ACPI SLIT (System Locality Information Table) defines the relative access times between processors, memory subsystems, and I/O subsystems. Operating systems that support the SLIT can use this information to improve performance by allocating resources and workloads more efficiently. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AdminEmail (Administrator E-mail Address) Member of Bios.v1_0_5.Bios
Description | Enter the server administrator’s e-mail address. |
Type | String |
Read Only | False |
AdminName (Administrator Name) Member of Bios.v1_0_5.Bios
Description | Enter the server administrator’s name text. |
Type | String |
Read Only | False |
AdminOtherInfo (Administrator Other Information) Member of Bios.v1_0_5.Bios
Description | Enter the server administrator’s information text. |
Type | String |
Read Only | False |
AdminPhone (Administrator Phone Number) Member of Bios.v1_0_5.Bios
Description | Enter the server administrator’s phone number text. |
Type | String |
Read Only | False |
AdvCrashDumpMode (Advanced Crash Dump Mode) Member of Bios.v1_0_5.Bios
Description | Use this option to enable the Advanced Crash Dump Mode. When enabled, the system will be configured to log additional debug information to the Active Health System logs when an unexpected system crash is experienced. This option should only be enabled when directed by qualified service personnel |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
AllowLoginWithIlo (Allow login with %s accounts) Member of Bios.v1_0_5.Bios
Description | Allows users to login with an iLO account with the CONFIGURE_BIOS privilege. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Amd5LevelPage (AMD 5-Level Page) Member of Bios.v1_0_5.Bios
Description | Support 5-Level Page to extend the size of virtual addresses from 48 bits to 57 bits, increasing the addressable virtual memory up to 128 PB. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AmdCdma (AMD Cacheable Direct Memory Access) Member of Bios.v1_0_5.Bios
Description | Enable or disable AMD CDMA (Cacheable Direct Memory Access), which allows PCIe I/O devices to write directly to cache bypassing DRAM. This may improve performance for some PCIe devices with TLP Processing Hint capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
AmdCstC2Latency (ACPI CST C2 Latency) Member of Bios.v1_0_5.Bios
Description | Select 800us for Linux kernel prior to version 6.0, 18us for version 6.0 or later |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
800us |
800 microsecond |
18us |
18 microsecond |
AmdDmaRemapping (AMD DMA Remapping) Member of Bios.v1_0_5.Bios
Description | This configures the DMA Remapping setting. DMA Remapping protects against memory corruption and malicious DMA attacks. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AmdL1Prefetcher (L1 Stream HW Prefetcher) Member of Bios.v1_0_5.Bios
Description | Use this option to disable L1 Stream HW prefetch feature. In some cases, setting this option to disabled can improve performance. Typically, setting this option to enabled provides better performance. Only disable this option after performing application benchmarking to verify improved performance in the environment. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AmdL2Prefetcher (L2 Stream HW Prefetcher) Member of Bios.v1_0_5.Bios
Description | Use this option to disable L2 Stream HW prefetch feature. In some cases, setting this option to disabled can improve performance. Typically, setting this option to enabled provides better performance. Only disable this option after performing application benchmarking to verify improved performance in the environment. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AmdMemPStates (Memory PStates) Member of Bios.v1_0_5.Bios
Description | This setting enables memory pstates |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AmdMemoryBurstRefresh (DRAM Burst Refresh Mode) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable DRAM Burst/Postponed Refresh mode |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AmdPeriodicDirectoryRinse (AMD Periodic Directory Rinse) Member of Bios.v1_0_5.Bios
Description | Enable Periodic Directory Rinse which may help manage directory capacity more efficiently. In workloads with significant system-wide sharing, like databases and HPC applications, using a shorter period for a directory rinse operation may improve performance. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
AmdSecureMemoryEncryption (AMD Secure Memory Encryption) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable SME |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AmdSecureNestedPaging (AMD Secure Nested Paging) Member of Bios.v1_0_5.Bios
Description | Use this option to enable AMD SEV-SNP. When enabled, SEV-SNP adds strong memory integrity protection to help prevent malicious hypervisor-based attacks like data replay, memory re-mapping, and more in order to create an isolated execution environment. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AmdVirtualDrtmDevice (AMD Virtual DRTM Device) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable the AMD Virtual DRTM Device. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
AmdXGMILinkSpeed (AMD xGMI Link Speed) Member of Bios.v1_0_5.Bios
Description | Configure xGMI link speed between two processors, Auto will use the platform defined setting. Other options will force the speed to user selected. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
AmdXGMILinkSpeed16 |
16 Gbps |
AmdXGMILinkSpeed18 |
18 Gbps |
AmdXGMILinkSpeed25 |
25 Gbps |
AmdXGMILinkSpeed32 |
32 Gbps |
ApplicationPowerBoost (Infinity Fabric Power Management) Member of Bios.v1_0_5.Bios
Description | When this feature is enabled, the EPYC processor will dynamically vary the clock frequency of the Infinity Fabric based on activity level. For NUMA optimized workloads, allowing the Infinity Fabric to run slower can lead to increased overall performance due to an increase in CPU boost. Disabling this feature may be necessary for latency sensitive workloads. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
AssetTagProtection (Asset Tag Protection) Member of Bios.v1_0_5.Bios
Description | Use this option to lock Asset Tag information. When set to lock, the Asset Tag is not erased if the default system settings are restored. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Locked |
Locked |
Unlocked |
Unlocked |
AutoPowerOn (Automatic Power-On) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the server power state when AC power is applied to the system. Restore Last Power State returns the system to its previous power state when AC power is restored after an AC power loss. Note: This option is not available on all systems. Always Power On and Always Power Off causes the system to always return to the “on” and “off” state, respectively, whenever power is applied, even if the system is in the “off” state when power is lost. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AlwaysPowerOn |
Always Power On |
AlwaysPowerOff |
Always Power Off |
RestoreLastState |
Restore Last Power State |
BootOrderPolicy (Boot Order Policy) Member of Bios.v1_0_5.Bios
Description | Use this option to configure how the system attempts to boot devices per the Boot Order list when no bootable device is found. If configured to ‘Retry Boot Order Indefinitely,’ the system continuously attempts to process the Boot Order list until a bootable device is found. If configured to ‘Attempt Boot Order Once,’ the system attempts to process all items in the Boot Order list once, and if unsuccessful, waits for user input to proceed. If configured for ‘Reset After Failed Boot Attempt,’ the system attempts to process all items in the Boot Order list once, and then reboots the system. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
RetryIndefinitely |
Retry Boot Order Indefinitely |
AttemptOnce |
Attempt Boot Order Once |
ResetAfterFailed |
Reset After Failed Boot Attempt |
CollabPowerControl (Collaborative Power Control) Member of Bios.v1_0_5.Bios
Description | For operating systems that support the Processor Clocking Control (PCC) Interface, enabling this option enables the Operating System to request processor frequency changes. For Operating Systems that do not support the PCC Interface this option has no effect on system operation. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
ConsistentDevNaming (Consistent Device Naming) Member of Bios.v1_0_5.Bios
Description | Use this option to select the level of Consistent Device Naming. On supported operating systems, NIC ports are named based on their location in the system. CDN Support for LOMs Only names Embedded NICs and FlexibleLOMs. Existing NIC connections retain their names until reinstalled under the OS environment. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
LomsAndSlots |
CDN Support for LOMs and Slots |
LomsOnly |
CDN Support for LOMs Only |
Disabled |
Disabled |
CustomPostMessage (Custom POST Message) Member of Bios.v1_0_5.Bios
Description | Enter a message to be displayed on POST screen during system startup. This feature limits POST screen messaging to 62 characters, special characters are also accepted. |
Type | String |
Read Only | False |
CustomPstate0 (Custom Pstate0) Member of Bios.v1_0_5.Bios
Description | Use this option to configure Pstate0 Frequency. Auto uses the processor fused values. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Manual |
Manual |
DataFabricCStateEnable (Data Fabric C-State Enable) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Data Fabric C-States |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
ForceEnabled |
Force Enabled |
Disabled |
Disabled |
DaylightSavingsTime (Daylight Savings Time) Member of Bios.v1_0_5.Bios
Description | This option controls the Daylight Savings Time (DST) adjustment to the displayed local time. If this option is disabled, the displayed local time will not be adjusted for DST. If this option is enabled, the displayed local time will be advanced by one hour. if this option is set to BMC control, the BMC will determine whether DST should be applied for the current time zone. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
DaylightSavingsTimeDisabled |
Daylight Savings Time is disabled |
DaylightSavingsTimeEnabled |
Daylight Savings Time is enabled |
DeterminismControl (Determinism Control) Member of Bios.v1_0_5.Bios
Description | Use this option to configure AMD determinism control. Auto uses the processor fused values. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
DeterminismCtrlAuto |
Auto |
DeterminismCtrlManual |
Manual |
Dhcpv4 (DHCPv4) Member of Bios.v1_0_5.Bios
Description | When enabled, this option enables obtaining the pre-boot network IPv4 configuration from a DHCP server. Individual settings are not available. When disabled, you must configure static IP address settings individually. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
DramControllerPowerDown (DRAM Controller Power Down) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable DRAM Controller power down |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
DynamicPowerCapping (Dynamic Power Capping Functionality) Member of Bios.v1_0_5.Bios
Description | Use this option to configure when the System BIOS executes power calibration during the boot process. In Auto mode, calibration is run the first time the server is booted, and is then only run again when the server’s hardware configuration changes, configuration settings change, or if the system determines a new calibration is necessary. When disabled, the calibration does not run, and Dynamic Power Capping is not supported. When enabled, the calibration is run on every boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Enabled |
Enabled |
Disabled |
Disabled |
EmbSata1Aspm (SATA Power Management(SALP)) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Aggressive Link Power Management(SALP). |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
EmbSata1Enable (SATA Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable SATA devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
EmbSata1PCIeOptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
EmbSata2Aspm (SATA Power Management(SALP)) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Aggressive Link Power Management(SALP). |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
EmbSata2Enable (SATA Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable SATA devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
EmbSata2PCIeOptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
EmbSata3Aspm (SATA Power Management(SALP)) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Aggressive Link Power Management(SALP). |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
EmbSata3Enable (SATA Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable SATA devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
EmbSata3PCIeOptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
EmbSata4Aspm (SATA Power Management(SALP)) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Aggressive Link Power Management(SALP). |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
EmbSata4Enable (SATA Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable SATA devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
EmbSata4PCIeOptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
EmbVideoConnection (Embedded Video Connection) Member of Bios.v1_0_5.Bios
Description | When configured for Auto mode, the external video connection to the embedded video controller is automatically disabled to save power when a monitor is not attached. It is automatically enabled when a monitor is attached, including when the server is operating. When configured for Always Disabled, the external video connection to the embedded video controller is disabled, and a monitor connected to this port does not display except during system boot. This can be used for security reasons. When configured for Always Enabled, the external video connection to the embedded video controller is always enabled. This option is only required if a monitor is attached with a monitor detection that does not function properly (making AUTO mode not work properly). Note: This option does not affect Integrated Remote Console video. Also, if you press F9 or F11 during system boot, the configured video connector behavior is overridden, and the video console remains enabled. This lets you reconfigure the Embedded Video Connection option even if the video is disabled. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
AlwaysDisabled |
Always Disabled |
AlwaysEnabled |
Always Enabled |
EmbeddedDiagnostics (Embedded Diagnostics) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Embedded Diagnostics functionality. If disabled, you cannot launch Embedded Diagnostics. Enable this option to use the Embedded Diagnostics functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
EmbeddedIpxe (Embedded iPXE) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable the Embedded iPXE. When enabled, you can launch the Embedded iPXE from the pre-boot environment. When enabled, you can add the Embedded iPXE can to the UEFI Boot Order by selecting the option entitled ‘Add Embedded iPXE to Boot Order’. When disabled, the Embedded iPXE is not available in the pre-boot environment, and you cannot add it to the UEFI boot order. The Embedded iPXE is an open source network boot application embedded in system BIOS that you can use to perform network boot.This option also enables the UEFI shell command ‘ipxe’ and an entry in Embedded Application list, both can be used to launch the Embedded iPXE. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
EmbeddedSerialPort (Embedded Serial Port) Member of Bios.v1_0_5.Bios
Description | Select this option to assign the logical COM port address and associated default resources to the selected physical serial port. The operating system can overwrite this setting.Note: Embedded Serial Port and Virtual Seral Port (VSP) cannot be set to the same port. If Embedded Serial Port is changed to the same port as VSP, the VSP will automatically be reassigned. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Com1Irq4 |
COM 1; IRQ4; I/O: 3F8h-3FFh |
Com2Irq3 |
COM 2; IRQ3; I/O: 2F8h-2FFh |
Disabled |
Disabled |
EmbeddedUefiShell (Embedded UEFI Shell) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable the Embedded UEFI Shell. If enabled, you can launch the Embedded UEFI Shell from the pre-boot environment. When enabled, you can add the Embedded UEFI Shell to the UEFI Boot Order by selecting the option entitled ‘Add Embedded UEFI Shell to Boot Order’. When disabled, the Embedded UEFI Shell is not available in the pre-boot environment, and you cannot add it to the UEFI boot order. The Embedded UEFI Shell is a pre-boot command line environment that you can use for scripting and running UEFI applications. It provides CLI-based commands to configure the server, update the System BIOS and other firmware, and obtain system information and error logs. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
EmsConsole (EMS Console) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the ACPI serial port settings, which include the ability to redirect the Windows Server Emergency Management console (EMS) through either the physical or virtual serial port. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Physical |
Physical Serial Port |
Virtual |
Virtual Serial Port |
EnabledCoresPerProc (Enabled Cores per Processor) Member of Bios.v1_0_5.Bios
Description | This option enables limiting the number of enabled processor cores per physical processor. You can set the number of enabled cores to a value supported by the physical processor. Setting the value to 0 or a value larger than the number of supported cores of the installed processor will result in all processor cores in the socket being enabled. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
CoresPerProc0 |
0 |
CoresPerProc2 |
2 |
CoresPerProc4 |
4 |
CoresPerProc6 |
6 |
CoresPerProc8 |
8 |
CoresPerProc12 |
12 |
CoresPerProc16 |
16 |
CoresPerProc20 |
20 |
CoresPerProc24 |
24 |
CoresPerProc28 |
28 |
CoresPerProc32 |
32 |
CoresPerProc36 |
36 |
CoresPerProc40 |
40 |
CoresPerProc48 |
48 |
CoresPerProc56 |
56 |
CoresPerProc60 |
60 |
CoresPerProc64 |
64 |
CoresPerProc72 |
72 |
CoresPerProc80 |
80 |
CoresPerProc84 |
84 |
CoresPerProc96 |
96 |
CoresPerProc112 |
112 |
EraseUserDefaults (Erase User Defaults) Member of Bios.v1_0_5.Bios
Description | Select this option to erase the user defaults backup. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
No |
No, Cancel |
Yes |
Yes, erase the current settings. |
ExtendedAmbientTemp (Extended Ambient Temperature Support) Member of Bios.v1_0_5.Bios
Description | Use this option to enable the server to operate at higher ambient temperatures than normally supported. These options are only supported with specific hardware configurations. See your server documentation before configuring the server to enable extended ambient temperature support. Improper system operation or damage to hardware components can result from enabling these options in unsupported configurations. Selecting Enabled for 40c Ambient (ASHRAE 3) enables the server to operate in environments with ambient temperatures up to 40 degrees Celsius. Selecting Enabled for 45c Ambient (ASHRAE 4) enables the server to operate in environments with ambient temperatures up to 45 degrees Celsius. Not all servers support both 40c Ambient (ASHRAE 3) and 45c Ambient (ASHRAE 4). |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
ASHRAE3 |
Enabled for 40c Ambient (ASHRAE 3) |
ASHRAE4 |
Enabled for 45c Ambient (ASHRAE 4) |
ExtendedMemTest (Extended Memory Test) Member of Bios.v1_0_5.Bios
Description | When enabled, the system validates memory during the memory initialization process. If uncorrectable memory errors are detected, the memory is mapped out, and the failed DIMMs are logged to the Integrated Management Log (IML). Enabling this option can result in a significant increase in the server boot time. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
F11BootMenu (One-Time Boot Menu (F11 Prompt)) Member of Bios.v1_0_5.Bios
Description | Use this option to disable the POST One-Time Boot F11 Prompt. Note: When disabled, shell ‘boot’ command is not available for use. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
FCScanPolicy (Fibre Channel/FCoE Scan Policy) Member of Bios.v1_0_5.Bios
Description | Use this option to change the default Fibre Channel or FCoE policy for scanning for boot targets. When configured for Scan All Targets, each installed FC/FCoE adapter scans all available targets. When configured for Scan Configured Targets Only, the FC/FCoE adapters only scan targets that are preconfigured in the devices settings. This option overrides any individual device settings configured in the device-specific setup.This option is only supported in UEFI Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Scan All Targets |
CardConfig |
Scan Configured Targets Only |
FanFailPolicy (Fan Failure Policy) Member of Bios.v1_0_5.Bios
Description | Use this option to configure how the server reacts when fans fail, resulting in the server not having required fans in operation. When configured for “Shutdown/Halt on Critical Fan Failures,” the server cannot boot or operate when it does not have required fans operating due to one or more fan failures. When configured for “Allow Operation with Critical Fan Failures,” the server can boot and operate if it does not have required fans operating due to one or more fan failures. It is recommended that you configure the Fan Failure Policy to the default state of “Shutdown/Halt on Critical Fan Failures.” Operating without the required fans operating can result in damage to hardware components. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Shutdown |
Shutdown/Halt on Critical Fan Failures |
Allow |
Allow Operation with Critical Fan Failures |
FanInstallReq (Fan Installation Requirements) Member of Bios.v1_0_5.Bios
Description | Use this option to configure how the server reacts when all required fans are not installed. When configured for Enable Messaging, the server displays messages and log events to the Integrated Management Log (IML) when required fans are not installed. The server can still boot and operate. When configured for Disable Messaging, the server does not display messages and log events when required fans are not installed. All indications that the server is operating without required fans are removed. It is recommended that you leave Fan Installation Requirements in the default state of Enable Messaging. Operating without the required fans can result in damage to hardware components. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
EnableMessaging |
Enable Messaging |
DisableMessaging |
Disable Messaging |
HourFormat (Hour Format) Member of Bios.v1_0_5.Bios
Description | Hour format, 24 Hours/12 Hours. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
24Hours |
24 Hours |
12Hours |
12 Hours |
HttpSupport (HTTP Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the UEFI HTTP(s) boot support when in UEFI Mode, and the ‘Discover Shell Auto-Start Script using DHCP’ option under ‘Embedded UEFI Shell’ settings. When ‘Auto’ is selected, the system automatically adds HTTP(S) boot options to the UEFI Boot Order list for every network port that is enabled for Network Boot. Selecting this option enables the system to boot to the HTTP or HTTPS URLs provided by the DHCP server. Any other URLs provided by the DHCP server are ignored. When ‘HTTP only’ is selected, the system automatically adds HTTP boot options to the UEFI Boot Order list for every network port that is enabled for Network Boot. Selecting this option enables the system to boot to the HTTP URLs provided by the DHCP server, and to ignore any HTTPS or other URLs that are provided. When ‘HTTPS only’ is selected, the system automatically adds HTTPS boot options to the UEFI Boot Order list for every network port that is enabled for Network Boot. Selecting this option enables the system to boot to the HTTPS URLs provided by the DHCP server, and to ignore any HTTP or other URLs that are provided. To enable HTTPS boot either by selecting ‘Auto’ or ‘HTTPS only’, you must enroll the respective TLS certificate of the HTTPS server under Server Security > TLS(HTTPS) Options. Note: This setting only affects the HTTP boot options added for the network ports, and the Discover Shell Auto-Start Script provided by the DHCP server. Other settings, such as Boot from URL, are not affected by this setting. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
HttpsOnly |
HTTPS only |
HttpOnly |
HTTP only |
Disabled |
Disabled |
InfinityFabricPstate (Infinity Fabric Performance State) Member of Bios.v1_0_5.Bios
Description | This feature allows for customizing the performance state (P-state) of the Infinity Fabric when Infinity Fabric Power Management is disabled. The default is Auto when Infinity Fabric Power Management is Enabled. P0 is ideal for latency sensitive or I/O centric workloads, P3 is ideal for achieving best core boost frequencies. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
P0 |
P0 |
P1 |
P1 |
P2 |
P2 |
P3 |
P3 |
Auto |
Auto |
IntelligentProvisioning (Intelligent Provisioning (F10 Prompt)) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable the Intelligent Provisioning functionality. When disabled, you are prevented from entering the Intelligent Provisioning environment by pressing F10 during server boot. You must set this option to enabled to use Intelligent Provisioning functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
IpmiWatchdogTimerAction (IPMI Watchdog Timer Action) Member of Bios.v1_0_5.Bios
Description | Use this option to set the timeout action upon expiration of the watchdog timer due to a server lockup. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
PowerCycle |
Power Cycle |
PowerDown |
Power Down |
WarmBoot |
Warm Boot |
IpmiWatchdogTimerStatus (IPMI Watchdog Timer) Member of Bios.v1_0_5.Bios
Description | Use this option to enable a Boot Time (POST) IPMI compliant Watchdog Timer (WDT) that is disabled when an IPMI command is issued to the system by the user and will not automatically be disabled. The WDT will be stopped when F9 or F10 hotkey is pressed during POST. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
IpmiWatchdogTimerOff |
Disabled |
IpmiWatchdogTimerOn |
Enabled |
IpmiWatchdogTimerTimeout (IPMI Watchdog Timer Timeout) Member of Bios.v1_0_5.Bios
Description | Use this option to set the wait timer before performing the desired timeout action on the server in the event of a server lockup. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Timeout10Min |
10 Minutes |
Timeout15Min |
15 Minutes |
Timeout20Min |
20 Minutes |
Timeout30Min |
30 Minutes |
Ipv4Address (IPv4 Address) Member of Bios.v1_0_5.Bios
Description | Use this option to specify the pre-boot network IPv4 address. Enter a static IP address using dotted-decimal notation (for example, 127.0.0.1). If DHCP is used (the DHCPv4 option is enabled), this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
Ipv4Gateway (IPv4 Gateway) Member of Bios.v1_0_5.Bios
Description | Use this option to specify the pre-boot network gateway IPv4 address. Enter a static IP address using dotted-decimal notation (for example, 127.0.0.1). If DHCP is used (the DHCPv4 option is enabled), this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
Ipv4PrimaryDNS (IPv4 Primary DNS) Member of Bios.v1_0_5.Bios
Description | Use this option to specify the pre-boot network Primary DNS Server IPv4 address. Enter a static IP address using dotted-decimal notation (for example, 127.0.0.1). If DHCP is used (the DHCPv4 option is enabled), this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
Ipv4SubnetMask (IPv4 Subnet Mask) Member of Bios.v1_0_5.Bios
Description | Use this option to specify the pre-boot network subnet mask. Enter a static IP address using dotted-decimal notation (for example, 255.255.255.0). If DHCP is used (the DHCPv4 option is enabled), this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
Ipv6Address (IPv6 Address) Member of Bios.v1_0_5.Bios
Description | Use this option to specify the pre-boot network IPv6 address. Enter a static IP address in the standard colon seperated format (for example, 1234::1000). If IPv6 Config Policy is set to Automatic, this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
Ipv6ConfigPolicy (IPv6 Config Policy) Member of Bios.v1_0_5.Bios
Description | When set to Automatic, this option enables obtaining the pre-boot network IPv6 configuration automatically. Individual settings are not available. When set to Manual, you must configure static IP address settings individually. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Automatic |
Automatic |
Manual |
Manual |
Ipv6Duid (IPv6 DHCP Unique Identifier) Member of Bios.v1_0_5.Bios
Description | Use this option to control the IPv6 DHCP Unique Identifier (DUID). If configured for Auto, the DUID is set using the Universal Unique Identifier (UUID) of the server, or using the DUID-LLT method if the server UUID is not available. If configured for DUID-LLT, the DUID is set based on the Link-layer Address Plus Time [DUID-LLT] method. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
DuidLlt |
DUID-LLT |
Ipv6Gateway (IPv6 Gateway) Member of Bios.v1_0_5.Bios
Description | Use this option to specify the pre-boot network gateway IPv6 address. Enter a static IP address in the standard colon seperated format (for example, 1234::1000). If IPv6 Config Policy is set to Automatic, this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
Ipv6PrimaryDNS (IPv6 Primary DNS) Member of Bios.v1_0_5.Bios
Description | Use this option to specify the pre-boot network Primary DNS Server IPv6 address. Enter a static IP address in the standard colon seperated format (for example, 1234::1000). If IPv6 Config Policy is set to Automatic, this setting is unavailable because the value is supplied automatically. |
Type | String |
Read Only | False |
IpxeAutoStartScriptLocation (iPXE Auto-Start Script Location) Member of Bios.v1_0_5.Bios
Description | Use this option to select the location of the Embedded iPXE startup script. For the ‘File Systems on Attached Media’ option, you must name the script file “startup.ipxe” and place it on a UEFI accessible local file system, such as a FAT32 partition on a USB disk or HDD. For the ‘Network Location’ option, the file must end with a .ipxe extension, and must be placed at an HTTP/HTTPS location accessible to the system. When you select the ‘Auto’ option, the system attempts to retrieve the startup script from the network location first, followed by locally attached media. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
AttachedMedia |
File Systems on Attached Media |
NetworkLocation |
Network Location |
IpxeBootOrder (Add Embedded iPXE to Boot Order) Member of Bios.v1_0_5.Bios
Description | When enabled, this option adds the Embedded iPXE as an entry in the UEFI Boot Order list. This option is only available when the Embedded iPXE is enabled. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
IpxeScriptAutoStart (iPXE Script Auto-Start) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable execution of the user supplied startup script for the Embedded iPXE. when enabled, you can configure Embedded iPXE to execute the startup script from a local media or a network location. When disable, Embedded iPXE will perform an auto discovery of startup script. You must name the script file “startup.ipxe” |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
IpxeScriptVerification (iPXE Script Verification) Member of Bios.v1_0_5.Bios
Description | Enable this option to allow verification of iPXE script files when Secure Boot is enabled. For successful execution of script, make sure that iPXE scripts are enrolled in the Secure Boot database (db). |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
IpxeStartupUrl (Network Location for iPXE Auto-Start Script) Member of Bios.v1_0_5.Bios
Description | Use this option to configure a network URL to a iPXE startup script. This option is available and used only when the Auto-Start Script Location is set to ‘Network Location’, or ‘Auto’, and the iPXE Auto-Start Script discovery.URLs in HTTP/HTTPS are accepted using either an IPv4 or IPv6 server address. For example, the URLs can be in any of the following formats: http://192.168.0.1/file/file.ipxe, http://example.com/file/file.ipxe, https://example.com/file/file.ipxe, http://[1234::1000]/file.ipxe. The file must end with an .ipxe extension. When configured, the Embedded iPXE attempts to load and execute the startup script from the network location pointed to by this URL. When an HTTPS URL is configured, you must enroll the respective HTTPS server’s TLS certificate under Server Security > TLS(HTTPS) Options. |
Type | String |
Read Only | False |
LastLevelCacheAsNUMANode (Last-Level Cache (LLC) As NUMA Node) Member of Bios.v1_0_5.Bios
Description | When enabled, LLC As NUMA Node divides the processor’s cores into an additional NUMA domain based on the L3 cache. Enabling this feature can increase performance for workloads that are NUMA aware and optimized. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
MaxMemBusFreqMHz (Maximum Memory Bus Frequency) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the memory system to run memory at a lower maximum speed than that supported by the installed processor and DIMM configuration. Setting this option to Auto configures the system to run memory at the maximum speed supported. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
MaxMemBusFreq4800 |
4800 MHz |
MaxMemBusFreq4400 |
4400 MHz |
MaxMemBusFreq4000 |
4000 MHz |
MaxMemBusFreq3600 |
3600 MHz |
MaxMemBusFreq3200 |
3200 MHz |
MaxPcieSpeed (Maximum PCI Express Speed) Member of Bios.v1_0_5.Bios
Description | If a PCI Express device does not run properly at its optimal speed, lowering the speed at which the device is running can address this issue. This option enables you to lower the maximum PCI Express speed at which the server allows PCI Express devices to operate. You can also use it to address issues with problematic PCI Express devices. Setting this value to Maximum Supported configures the platform to run at the maximum speed supported by the platform or the PCIe device, whichever is lower. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
PerPortCtrl |
Per Port Control |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PcieGen3 |
PCIe Generation 3.0 |
PcieGen4 |
PCIe Generation 4.0 |
MemPatrolScrubbing (Memory Patrol Scrubbing) Member of Bios.v1_0_5.Bios
Description | This option corrects memory soft errors so that, over the length of the system runtime, the risk of producing multi-bit and uncorrectable errors is reduced. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
MemRefreshRate (Memory Refresh Rate) Member of Bios.v1_0_5.Bios
Description | This option controls the refresh rate of the memory controller and might affect the performance and resiliency of the server memory. It is recommended that you leave this setting in the default state unless indicated in other documentation for this server. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Refreshx1 |
1x Refresh |
Refreshx2 |
2x Refresh |
MicrosoftSecuredCoreSupport (Microsoft® Secured-core Support) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the server for Microsoft® Secured-core Support. When enabled, various virtualization and security settings will be automatically enabled. Please consult operating system documentation for more details. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
MinProcIdlePower (Minimum Processor Idle Power Core C-State) Member of Bios.v1_0_5.Bios
Description | You can only configure this option if Workload Profile is set to Custom. Use this option to select the lowest idle power state (C-state) of the processor that the operating system uses. The higher the C-state, the lower the power usage of that idle state. (C6 is the lowest power idle state supported by the processor). |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
C6 |
C6 State |
C1 |
C1 State |
NoCStates |
No C-states |
MinimumSevAsid (Minimum SEV ASID) Member of Bios.v1_0_5.Bios
Description | This configures the minimum address space identifier (ASID) that can be used for AMD Secure Encrypted Virtualization (SEV) enabled guests. ASID below this number are only available to SEV enable guest that also enable SEV-ES (Encrypted State) |
Type | Integer |
Read Only | False |
MixedPowerSupplyReporting (Mixed Power Supply Reporting) Member of Bios.v1_0_5.Bios
Description | When enabled, the server logs a message that a mixed power supply configuration is present. When disabled, the server no longer logs messages that a mixed power supply configuration is present. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NetworkBootRetry (Network Boot Retry Support) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the Network Boot Retry Support. When enabled, the system BIOS attempts to boot the network device up to the number of times configured in the Network Boot Retry Count option before attempting to boot the next network device. This setting only takes effect when attempting to boot a network device from the F12 function key and one-time boot options. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
NetworkBootRetryCount (Network Boot Retry Count) Member of Bios.v1_0_5.Bios
Description | Use this option to control the number of times the system BIOS attempts to boot a network device. The valid range is from 0 to 20. |
Type | Integer |
Read Only | False |
NicBoot1 (Embedded NIC 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot10 (Embedded NIC 10 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot11 (Embedded NIC 11 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot12 (Embedded NIC 12 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot2 (Embedded NIC 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot3 (Embedded NIC 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot4 (Embedded NIC 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot5 (Embedded NIC 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot6 (Embedded NIC 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot7 (Embedded NIC 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot8 (Embedded NIC 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NicBoot9 (Embedded NIC 9 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
NumaGroupSizeOpt (NUMA Group Size Optimization) Member of Bios.v1_0_5.Bios
Description | Use this option to configure how the System BIOS reports the size of a NUMA node (number of logical processors), which assists the Operating System in grouping processors for application use (referred to as Kgroups). The default setting of Clustered provides better performance due to optimizing the resulting groups along NUMA boundaries. However, some applications might not be optimized to take advantage of processors spanning multiple groups. In such cases, selecting the Flat option might be necessary in order for those applications to utilize more logical processors. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Flat |
Flat |
Clustered |
Clustered |
NumaMemoryDomainsPerSocket (NUMA memory domains per socket) Member of Bios.v1_0_5.Bios
Description | Select this option to configure the number of NUMA memory domains per socket.If LLC As NUMA Node is enabled, total NUMA node number depends on total CCX number. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
OneMemoryDomainPerSocket |
One memory domain per socket |
TwoMemoryDomainsPerSocket |
Two memory domains per socket |
FourMemoryDomainsPerSocket |
Four memory domains per socket |
Auto |
Auto |
NvmeOptionRom (Embedded NVM Express Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable embedded NVM Express Option ROM. When enabled, the system loads the NVM Express Option ROM provided by the system BIOS. When disabled, the system loads the NVM Express Option ROM provided by the adapter. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Ocp1AuxiliaryPower (OCP Slot 1 Auxiliary Power) Member of Bios.v1_0_5.Bios
Description | This option can be used to control if the PCIe device is granted auxiliary power. When enabled, the device is granted auxiliary power and is capable of operation however system fans may run to ensure appropriate cooling. When disabled, the device will not be able to respond to any transactions such as Wake On LAN when the server is in a auxiliary power state. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Ocp2AuxiliaryPower (OCP Slot 2 Auxiliary Power) Member of Bios.v1_0_5.Bios
Description | This option can be used to control if the PCIe device is granted auxiliary power. When enabled, the device is granted auxiliary power and is capable of operation however system fans may run to ensure appropriate cooling. When disabled, the device will not be able to respond to any transactions such as Wake On LAN when the server is in a auxiliary power state. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
OmitBootDeviceEvent (Omit Boot Device Event) Member of Bios.v1_0_5.Bios
Description | Use this option to record Omit Boot Device Event. If enabled, PCR Boot Attempt Measurements will be disabled and measurement in PCR[4] will not be recorded. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PackagePowerLimitControlMode (Package Power Limit Control Mode) Member of Bios.v1_0_5.Bios
Description | This is a per processor Package Power Limit value applicable for all populated processors in the system. AUTO uses the default processor value. Modify the power limit in watts, as instructed by qualified personnel. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Manual |
Manual |
PackagePowerLimitValue (Package Power Limit value) Member of Bios.v1_0_5.Bios
Description | This options control the package power limit allowed in Watts |
Type | Integer |
Read Only | False |
PatrolScrubDuration (Patrol Scrub Duration) Member of Bios.v1_0_5.Bios
Description | Select this option to configure the duration interval of when to run the patrol scrubber if patrol scrub is enabled.Value is in hours. |
Type | Integer |
Read Only | False |
PciSlot10Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot10Bifurcation (PCIe Slot 10 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot10Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot10LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot10OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot11Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot11Bifurcation (PCIe Slot 11 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot11Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot11LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot11OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot12Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot12Bifurcation (PCIe Slot 12 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot12Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot12LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot12OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot13Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot13Bifurcation (PCIe Slot 13 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot13Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot13LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot13OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot14Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot14Bifurcation (PCIe Slot 14 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot14Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot14LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot14OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot15Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot15Bifurcation (PCIe Slot 15 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot15Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot15LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot15OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot16Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot16Bifurcation (PCIe Slot 16 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot16Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot16LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot16OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot17Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot17Bifurcation (PCIe Slot 17 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot17Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot17LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot17OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot18Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot18Bifurcation (PCIe Slot 18 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot18Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot18LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot18OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot19Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot19Bifurcation (PCIe Slot 19 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot19Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot19LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot19OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot1Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot1Bifurcation (PCIe Slot 1 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot1Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot1LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PcieGen3 |
PCIe Generation 3.0 |
PciSlot1OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot20Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot20Bifurcation (PCIe Slot 20 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot20Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot20LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot20OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot21Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot21Bifurcation (PCIe Slot 21 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot21Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot21LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot21OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot22Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot22Bifurcation (PCIe Slot 22 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot22Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot22LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot22OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot23Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot23Bifurcation (PCIe Slot 23 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot23Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot23LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot23OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot2Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot2Bifurcation (PCIe Slot 2 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot2Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot2LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PcieGen3 |
PCIe Generation 3.0 |
PciSlot2OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot3Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot3Bifurcation (PCIe Slot 3 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot3Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot3LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PcieGen3 |
PCIe Generation 3.0 |
PciSlot3OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot4Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot4Bifurcation (PCIe Slot 4 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot4Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot4LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PcieGen3 |
PCIe Generation 3.0 |
PciSlot4OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot5Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot5Bifurcation (PCIe Slot 5 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot5Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot5LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PcieGen3 |
PCIe Generation 3.0 |
PciSlot5OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot6Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot6Bifurcation (PCIe Slot 6 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot6Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot6LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PcieGen3 |
PCIe Generation 3.0 |
PciSlot6OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot7Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot7Bifurcation (PCIe Slot 7 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot7Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot7LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PcieGen3 |
PCIe Generation 3.0 |
PciSlot7OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot8Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot8Bifurcation (PCIe Slot 8 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot8Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot8LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PcieGen3 |
PCIe Generation 3.0 |
PciSlot8OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PciSlot9Aspm (PCIe Power Management(ASPM)) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Power Management (ASPM) support for the selected device. When configured for L0s Enabled, the selected device’s link enters a standby energy savings state. When configured for L1 Enabled, the selected device’s link enters a lower power standby state at the expense of a longer exit latency. When configured for L1 and L0s Enabled, the selected device’s link enters either power savings mode, depending on link utilization, and provides the highest energy savings. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
AspmL1Enabled |
L1 Enabled |
PciSlot9Bifurcation (PCIe Slot 9 Bifurcation) Member of Bios.v1_0_5.Bios
Description | Use this option to bifurcate the selected PCIe slot. When No Bifurcation is selected, the PCIe slot will train a single link at the maximum width supported by the slot and end point. When Slot Bifurcated is selected, the PCIe slot will be bifurcated into two equal width slots. When Slot Dual Bifurcate (quadfurcate) is selected, the PCIe slot will be bifurcated into four equal width slots.Note: Only change this option if the device installed in the slot supports this capability. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoBifurcation |
No Bifurcation |
SlotBifurcated |
Bifurcate |
SlotDualBifurcated |
Dual Bifurcate |
PciSlot9Enable (PCIe Device Disable) Member of Bios.v1_0_5.Bios
Description | Select this option to enable or disable PCI devices. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
PciSlot9LinkSpeed (PCIe Link Speed) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the PCIe Link Speed for the selected device. When configured for Auto, the selected device trains at the maximum supported speed of the PCIe link. When configured for PCIe Generation 2 Link Speed, the selected device trains at a maximum of PCIe Generation 2 speed. When configured for PCIe Generation Link 1 speed, the selected device trains at a maximum of PCIe Generation 1 speed. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
PcieGen1 |
PCIe Generation 1.0 |
PcieGen2 |
PCIe Generation 2.0 |
PciSlot9OptionROM (PCIe Option ROM) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable Device Option ROM |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PerformanceDeterminism (Performance Determinism) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the AMD Processor for Performance or Power Determinism. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
PerformanceDeterministic |
Performance Deterministic |
PowerDeterministic |
Power Deterministic |
PlatformCertificate (Platform Certificate Support) Member of Bios.v1_0_5.Bios
Description | Enable/Disable Platform Certificate Support.NOTE: This feature will only build the certificate data when a TPM 2.0 device is enabled and visible. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PlatformRASPolicy (Platform RAS Policy) Member of Bios.v1_0_5.Bios
Description | This option controls the platform Resiliency and Serviceability (RAS) policy. When in Firmware First mode (default), the BIOS will monitor corrected errors and log an event for any cases where the customer needs to take action on corrected errors. The OS will not monitor and log corrected errors. In OS First mode, corrected errors are unmasked to the OS and the OS will control the policy for logging corrected errors. With some operating systems, the OS will log all corrected errors. Corrected errors are an expected and natural occurrence and there is typically no action is required based on OS logging of corrected errors. Note there is no guarantee that the BIOS can properly log corrected error events when in OS First mode. It is recommended that this option is left in its default configuration. Warranty support will only be provided for memory errors that have exceeded correctable error thresholds as determined by Customer Support. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
FirmwareFirst |
Firmware First |
OSFirst |
OS First |
PostAsr (POST ASR) Member of Bios.v1_0_5.Bios
Description | Use this option to configure POST Automatic Server Recovery (ASR).When Automatic Server Recovery is enabled, you can use this option to set the time to wait before rebooting the server in the event of a server lockup This timer is only avaiable during POST and is not enabled at operating system boot. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
PostAsrOff |
POST ASR Off |
PostAsrOn |
POST ASR On |
PostAsrDelay (POST ASR Timer) Member of Bios.v1_0_5.Bios
Description | Use this option to set the wait timer before rebooting the server in the event of a server lockup. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Delay30Min |
30 Minute Timer |
Delay20Min |
20 Minute Timer |
Delay15Min |
15 Minute Timer |
Delay10Min |
10 Minute Timer |
PostBootProgress (POST Verbose Boot Progress) Member of Bios.v1_0_5.Bios
Description | Use this option to enable verbose boot progress messaging. Because this option displays additional debug information to the screen and serial console, it might be helpful for determining why a server became unresponsive during the boot process. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Serial |
Serial Only |
All |
All |
PostDiscoveryMode (UEFI POST Discovery Mode) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the UEFI POST Discovery Mode. When Auto is selected, the system selectively starts devices which are required for booting the devices in the UEFI Boot Order list. Note: For some situations like system configuration change, the system will change to start all devices for discovering all boot devices. When Force Full Discovery is selected, the system starts all devices in the system providing full boot target availability. Note: When Force Full Discovery is selected, boot time might significantly increase. When Force Fast Discovery is selected, the system starts as few devices as possible to get minimal boot time. Note: When Force Fast Discovery is selected, some unsupported devices may not work properly. You may need to replace the unsupported device with one that supports Fast Discovery. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
ForceFullDiscovery |
Force Full Discovery |
ForceFastDiscovery |
Force Fast Discovery |
PostF1Prompt (POST F1 Prompt) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the system to display the F1 key on the server POST screen. If an error is encountered, you can press the F1 key to continue with the server power-up sequence. Select one of the following options: Delayed 20 Seconds - If an error occurs, the system pauses for 20 seconds at the F1 prompt and continues to boot the OS. Delayed 2 Seconds - If an error occurs, the system pauses for 2 seconds at the F1 prompt and continues to boot the OS. Disabled - If an error occurs, the system bypasses the F1 prompt and continues to boot the OS. Note: For critical errors, the system pauses for 20 seconds at the F1 prompt, regardless of how this option is configured. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Delayed20Sec |
Delayed 20 seconds |
Delayed2Sec |
Delayed 2 seconds |
Disabled |
Disabled |
PostScreenMode (POST Screen Mode) Member of Bios.v1_0_5.Bios
Description | Select the display mode during boot up. When set to quiet mode, only the logo and progress bar are displayed. All informational messages and boot up graphics are hidden. When set to verbose mode, all boot up messages and graphics are displayed. You can also change the display mode from quiet to verbose while booting by pressing the TAB key when hotkeys are enabled. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
QuietMode |
Quiet Mode |
VerboseMode |
Verbose Mode |
PostVideoSupport (POST Video Support) Member of Bios.v1_0_5.Bios
Description | Use this option to configure the POST Video Support setting. When set to Display All, the system will display POST video to all installed video controllers. When set to Display Embedded Only, the system will only display POST video to the embedded video controller. This option is only supported in UEFI Boot Mode and only applies to video output during the POST (pre-boot) environment. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
DisplayAll |
Display All |
DisplayEmbeddedOnly |
Display Embedded Only |
PowerButton (Power Button Mode) Member of Bios.v1_0_5.Bios
Description | Disabling this option disables the momentary power button functionality. This option does not affect the four-second power button override or the remote power control functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
PowerOnDelay (Power-On Delay) Member of Bios.v1_0_5.Bios
Description | Use this option to delay the server from turning on for a specified time. Pressing the power button (using the Virtual Power Button), or Wake-ON LAN events, and RTC Wake-up events override the delay and power on the server without any additional delay. This enables staggering when servers power-up after a power loss to prevent power usage spikes.Note that the actual delay before the server is powered on will be longer than the specified time because the server must always wait for iLO FW to initialize before the server attempts to power on. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoDelay |
No Delay |
Random |
Random Delay |
Delay15Sec |
15 Second Delay |
Delay30Sec |
30 Second Delay |
Delay45Sec |
45 Second Delay |
Delay60Sec |
60 Second Delay |
PowerRegulator (Power Regulator) Member of Bios.v1_0_5.Bios
Description | You can only configure this option if the Workload Profile is set to Custom. Use this option to configure the following Power Regulator support: - Static High Performance Mode: Processors run in their maximum power/performance state at all times, regardless of the OS power management policy. - OS Control Mode: Processors run in their maximum power/performance state at all times unless the OS enables a power management policy. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
StaticHighPerf |
Static High Performance Mode |
OsControl |
OS Control Mode |
PreBootNetwork (Pre-Boot Network Interface) Member of Bios.v1_0_5.Bios
Description | Use this option to select the network interface used for pre-boot network connections. When the selection is Auto, the system uses the first available port with a network connection. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Slot1NicPort1 |
Slot 1 NIC Port 1 |
Slot1NicPort2 |
Slot 1 NIC Port 2 |
Slot1NicPort3 |
Slot 1 NIC Port 3 |
Slot1NicPort4 |
Slot 1 NIC Port 4 |
Slot1NicPort5 |
Slot 1 NIC Port 5 |
Slot1NicPort6 |
Slot 1 NIC Port 6 |
Slot1NicPort7 |
Slot 1 NIC Port 7 |
Slot1NicPort8 |
Slot 1 NIC Port 8 |
Slot2NicPort1 |
Slot 2 NIC Port 1 |
Slot2NicPort2 |
Slot 2 NIC Port 2 |
Slot2NicPort3 |
Slot 2 NIC Port 3 |
Slot2NicPort4 |
Slot 2 NIC Port 4 |
Slot2NicPort5 |
Slot 2 NIC Port 5 |
Slot2NicPort6 |
Slot 2 NIC Port 6 |
Slot2NicPort7 |
Slot 2 NIC Port 7 |
Slot2NicPort8 |
Slot 2 NIC Port 8 |
Slot3NicPort1 |
Slot 3 NIC Port 1 |
Slot3NicPort2 |
Slot 3 NIC Port 2 |
Slot3NicPort3 |
Slot 3 NIC Port 3 |
Slot3NicPort4 |
Slot 3 NIC Port 4 |
Slot3NicPort5 |
Slot 3 NIC Port 5 |
Slot3NicPort6 |
Slot 3 NIC Port 6 |
Slot3NicPort7 |
Slot 3 NIC Port 7 |
Slot3NicPort8 |
Slot 3 NIC Port 8 |
Slot4NicPort1 |
Slot 4 NIC Port 1 |
Slot4NicPort2 |
Slot 4 NIC Port 2 |
Slot4NicPort3 |
Slot 4 NIC Port 3 |
Slot4NicPort4 |
Slot 4 NIC Port 4 |
Slot4NicPort5 |
Slot 4 NIC Port 5 |
Slot4NicPort6 |
Slot 4 NIC Port 6 |
Slot4NicPort7 |
Slot 4 NIC Port 7 |
Slot4NicPort8 |
Slot 4 NIC Port 8 |
Slot5NicPort1 |
Slot 5 NIC Port 1 |
Slot5NicPort2 |
Slot 5 NIC Port 2 |
Slot5NicPort3 |
Slot 5 NIC Port 3 |
Slot5NicPort4 |
Slot 5 NIC Port 4 |
Slot5NicPort5 |
Slot 5 NIC Port 5 |
Slot5NicPort6 |
Slot 5 NIC Port 6 |
Slot5NicPort7 |
Slot 5 NIC Port 7 |
Slot5NicPort8 |
Slot 5 NIC Port 8 |
Slot6NicPort1 |
Slot 6 NIC Port 1 |
Slot6NicPort2 |
Slot 6 NIC Port 2 |
Slot6NicPort3 |
Slot 6 NIC Port 3 |
Slot6NicPort4 |
Slot 6 NIC Port 4 |
Slot6NicPort5 |
Slot 6 NIC Port 5 |
Slot6NicPort6 |
Slot 6 NIC Port 6 |
Slot6NicPort7 |
Slot 6 NIC Port 7 |
Slot6NicPort8 |
Slot 6 NIC Port 8 |
Slot7NicPort1 |
Slot 7 NIC Port 1 |
Slot7NicPort2 |
Slot 7 NIC Port 2 |
Slot7NicPort3 |
Slot 7 NIC Port 3 |
Slot7NicPort4 |
Slot 7 NIC Port 4 |
Slot7NicPort5 |
Slot 7 NIC Port 5 |
Slot7NicPort6 |
Slot 7 NIC Port 6 |
Slot7NicPort7 |
Slot 7 NIC Port 7 |
Slot7NicPort8 |
Slot 7 NIC Port 8 |
Slot8NicPort1 |
Slot 8 NIC Port 1 |
Slot8NicPort2 |
Slot 8 NIC Port 2 |
Slot8NicPort3 |
Slot 8 NIC Port 3 |
Slot8NicPort4 |
Slot 8 NIC Port 4 |
Slot8NicPort5 |
Slot 8 NIC Port 5 |
Slot8NicPort6 |
Slot 8 NIC Port 6 |
Slot8NicPort7 |
Slot 8 NIC Port 7 |
Slot8NicPort8 |
Slot 8 NIC Port 8 |
Slot9NicPort1 |
Slot 9 NIC Port 1 |
Slot9NicPort2 |
Slot 9 NIC Port 2 |
Slot9NicPort3 |
Slot 9 NIC Port 3 |
Slot9NicPort4 |
Slot 9 NIC Port 4 |
Slot9NicPort5 |
Slot 9 NIC Port 5 |
Slot9NicPort6 |
Slot 9 NIC Port 6 |
Slot9NicPort7 |
Slot 9 NIC Port 7 |
Slot9NicPort8 |
Slot 9 NIC Port 8 |
Slot10NicPort1 |
Slot 10 NIC Port 1 |
Slot10NicPort2 |
Slot 10 NIC Port 2 |
Slot10NicPort3 |
Slot 10 NIC Port 3 |
Slot10NicPort4 |
Slot 10 NIC Port 4 |
Slot10NicPort5 |
Slot 10 NIC Port 5 |
Slot10NicPort6 |
Slot 10 NIC Port 6 |
Slot10NicPort7 |
Slot 10 NIC Port 7 |
Slot10NicPort8 |
Slot 10 NIC Port 8 |
Slot11NicPort1 |
Slot 11 NIC Port 1 |
Slot11NicPort2 |
Slot 11 NIC Port 2 |
Slot11NicPort3 |
Slot 11 NIC Port 3 |
Slot11NicPort4 |
Slot 11 NIC Port 4 |
Slot11NicPort5 |
Slot 11 NIC Port 5 |
Slot11NicPort6 |
Slot 11 NIC Port 6 |
Slot11NicPort7 |
Slot 11 NIC Port 7 |
Slot11NicPort8 |
Slot 11 NIC Port 8 |
Slot12NicPort1 |
Slot 12 NIC Port 1 |
Slot12NicPort2 |
Slot 12 NIC Port 2 |
Slot12NicPort3 |
Slot 12 NIC Port 3 |
Slot12NicPort4 |
Slot 12 NIC Port 4 |
Slot12NicPort5 |
Slot 12 NIC Port 5 |
Slot12NicPort6 |
Slot 12 NIC Port 6 |
Slot12NicPort7 |
Slot 12 NIC Port 7 |
Slot12NicPort8 |
Slot 12 NIC Port 8 |
Slot13NicPort1 |
Slot 13 NIC Port 1 |
Slot13NicPort2 |
Slot 13 NIC Port 2 |
Slot13NicPort3 |
Slot 13 NIC Port 3 |
Slot13NicPort4 |
Slot 13 NIC Port 4 |
Slot13NicPort5 |
Slot 13 NIC Port 5 |
Slot13NicPort6 |
Slot 13 NIC Port 6 |
Slot13NicPort7 |
Slot 13 NIC Port 7 |
Slot13NicPort8 |
Slot 13 NIC Port 8 |
Slot14NicPort1 |
Slot 14 NIC Port 1 |
Slot14NicPort2 |
Slot 14 NIC Port 2 |
Slot14NicPort3 |
Slot 14 NIC Port 3 |
Slot14NicPort4 |
Slot 14 NIC Port 4 |
Slot14NicPort5 |
Slot 14 NIC Port 5 |
Slot14NicPort6 |
Slot 14 NIC Port 6 |
Slot14NicPort7 |
Slot 14 NIC Port 7 |
Slot14NicPort8 |
Slot 14 NIC Port 8 |
Slot15NicPort1 |
Slot 15 NIC Port 1 |
Slot15NicPort2 |
Slot 15 NIC Port 2 |
Slot15NicPort3 |
Slot 15 NIC Port 3 |
Slot15NicPort4 |
Slot 15 NIC Port 4 |
Slot15NicPort5 |
Slot 15 NIC Port 5 |
Slot15NicPort6 |
Slot 15 NIC Port 6 |
Slot15NicPort7 |
Slot 15 NIC Port 7 |
Slot15NicPort8 |
Slot 15 NIC Port 8 |
Slot16NicPort1 |
Slot 16 NIC Port 1 |
Slot16NicPort2 |
Slot 16 NIC Port 2 |
Slot16NicPort3 |
Slot 16 NIC Port 3 |
Slot16NicPort4 |
Slot 16 NIC Port 4 |
Slot16NicPort5 |
Slot 16 NIC Port 5 |
Slot16NicPort6 |
Slot 16 NIC Port 6 |
Slot16NicPort7 |
Slot 16 NIC Port 7 |
Slot16NicPort8 |
Slot 16 NIC Port 8 |
Slot17NicPort1 |
Slot 17 NIC Port 1 |
Slot17NicPort2 |
Slot 17 NIC Port 2 |
Slot17NicPort3 |
Slot 17 NIC Port 3 |
Slot17NicPort4 |
Slot 17 NIC Port 4 |
Slot17NicPort5 |
Slot 17 NIC Port 5 |
Slot17NicPort6 |
Slot 17 NIC Port 6 |
Slot17NicPort7 |
Slot 17 NIC Port 7 |
Slot17NicPort8 |
Slot 17 NIC Port 8 |
Slot18NicPort1 |
Slot 18 NIC Port 1 |
Slot18NicPort2 |
Slot 18 NIC Port 2 |
Slot18NicPort3 |
Slot 18 NIC Port 3 |
Slot18NicPort4 |
Slot 18 NIC Port 4 |
Slot18NicPort5 |
Slot 18 NIC Port 5 |
Slot18NicPort6 |
Slot 18 NIC Port 6 |
Slot18NicPort7 |
Slot 18 NIC Port 7 |
Slot18NicPort8 |
Slot 18 NIC Port 8 |
Slot19NicPort1 |
Slot 19 NIC Port 1 |
Slot19NicPort2 |
Slot 19 NIC Port 2 |
Slot19NicPort3 |
Slot 19 NIC Port 3 |
Slot19NicPort4 |
Slot 19 NIC Port 4 |
Slot19NicPort5 |
Slot 19 NIC Port 5 |
Slot19NicPort6 |
Slot 19 NIC Port 6 |
Slot19NicPort7 |
Slot 19 NIC Port 7 |
Slot19NicPort8 |
Slot 19 NIC Port 8 |
Slot20NicPort1 |
Slot 20 NIC Port 1 |
Slot20NicPort2 |
Slot 20 NIC Port 2 |
Slot20NicPort3 |
Slot 20 NIC Port 3 |
Slot20NicPort4 |
Slot 20 NIC Port 4 |
Slot20NicPort5 |
Slot 20 NIC Port 5 |
Slot20NicPort6 |
Slot 20 NIC Port 6 |
Slot20NicPort7 |
Slot 20 NIC Port 7 |
Slot20NicPort8 |
Slot 20 NIC Port 8 |
Slot21NicPort1 |
Slot 21 NIC Port 1 |
Slot21NicPort2 |
Slot 21 NIC Port 2 |
Slot21NicPort3 |
Slot 21 NIC Port 3 |
Slot21NicPort4 |
Slot 21 NIC Port 4 |
Slot21NicPort5 |
Slot 21 NIC Port 5 |
Slot21NicPort6 |
Slot 21 NIC Port 6 |
Slot21NicPort7 |
Slot 21 NIC Port 7 |
Slot21NicPort8 |
Slot 21 NIC Port 8 |
Slot22NicPort1 |
Slot 22 NIC Port 1 |
Slot22NicPort2 |
Slot 22 NIC Port 2 |
Slot22NicPort3 |
Slot 22 NIC Port 3 |
Slot22NicPort4 |
Slot 22 NIC Port 4 |
Slot22NicPort5 |
Slot 22 NIC Port 5 |
Slot22NicPort6 |
Slot 22 NIC Port 6 |
Slot22NicPort7 |
Slot 22 NIC Port 7 |
Slot22NicPort8 |
Slot 22 NIC Port 8 |
PrebootNetworkEnvPolicy (Pre-Boot Network Environment) Member of Bios.v1_0_5.Bios
Description | Use this option to set the preference for Pre-Boot Network. If configured for Auto, all the network operations initiated in the pre boot environment occur over IPv4 or IPv6. The order of the existing network boot targets is not modified in the UEFI Boot Order list. New network boot targets are added to the end of the list using the default policy of the System BIOS. If configured for IPv4, all the network operations initiated in the pre boot environment only occur over IPv4. All existing IPv6 network boot targets are removed in the UEFI Boot Order. No new IPv6 network boot targets are added to the list. If configured for IPv6, all the network operations initiated in the pre boot environment only occur over IPv6. All existing IPv4 network boot targets in the UEFI Boot Order are removed. No new IPv4 network boot targets are added to the list. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
IPv4 |
IPv4 |
IPv6 |
IPv6 |
PrebootNetworkProxy (Pre-Boot Network Proxy) Member of Bios.v1_0_5.Bios
Description | Use this option to configure a pre-boot network proxy. When set, network operations for ‘Pre-Boot Network Interface’ are attempted through the configured proxy. The proxy must be in an HTTP URL format, and can be specified as http://IPv4_address:port, http://IPv6 address:port or http://FQDN:port. |
Type | String |
Read Only | False |
ProcAMDBoost (AMD Core Performance Boost) Member of Bios.v1_0_5.Bios
Description | AMD Core Performance Boost enables the processor to transition to a higher frequency than the processor’s rated speed if the processor has available power and is within temperature specifications. Disabling this option reduces power usage and also reduces the system’s maximum achievable performance under some workloads. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
ProcAMDBoostControl (AMD Fmax Boost Limit Control) Member of Bios.v1_0_5.Bios
Description | AMD Fmax Boost Limit setting sets the maximum processor boost frequency. Auto will allow the processor to run at the highest possible boost frequencies. Manual will allow the user to configure a lower maximum boost frequency. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AmdFmaxBoostAuto |
Auto |
AmdFmaxBoostManual |
Manual |
ProcAes (Processor AES-NI Support) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable the Advanced Encryption Standard Instruction Set (AES-NI) in the processor. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
ProcAmdFmax (AMD Fmax Boost Limit) Member of Bios.v1_0_5.Bios
Description | AMD Fmax Boost Limit setting sets the maximum processor boost frequency. |
Type | Integer |
Read Only | False |
ProcAmdIoVt (AMD I/O Virtualization Technology) Member of Bios.v1_0_5.Bios
Description | This option enables or disables capabilities provided by AMD I/O Virtualization (IOMMU) functionality. This option can be left enabled for all operating environments, including those that do not make use of this capability. When this option is enabled on systems containing 1TB or more of installed memory, 4GB of memory will be reserved near the 1TB address boundary and will not be available to the operating system. When this option is enabled on systems with less than 1TB of installed memory, the memory mapped I/O address range will begin at the 1TB address boundary which should have no impact to system operation and would not impact the memory available to the operating system. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
ProcSMT (AMD SMT Option) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable AMD SMT. When enabled, each physical processor core operates as two logical processor cores. When disabled, each physical processor core operates as only one logical processor core. Enabling this option can improve overall performance for applications that benefit from a higher processor core count. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
ProcX2Apic (Processor x2APIC Support) Member of Bios.v1_0_5.Bios
Description | x2APIC support enables operating systems to run more efficiently on high core count configurations. It also optimizes interrupt distribution in virtualized environments. In most cases, set this option to Auto. This configures the operating system to enable x2APIC support depending on the processor and chipset design. When this setting is greyed-out, X2Apic was automatically enabled. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
ForceEnabled |
Force Enabled |
ProductId (Product ID) Member of Bios.v1_0_5.Bios
Description | Use this option to set the system product ID. This value must always match the product ID sticker located on the chassis. |
Type | String |
Read Only | False |
Pstate0Frequency (Pstate0 Frequency (MHz)) Member of Bios.v1_0_5.Bios
Description | Specifies core frequency (MHz) |
Type | Integer |
Read Only | False |
RedundantPowerSupplyGpuDomain (Redundant Power Supply Mode - GPU Domain) Member of Bios.v1_0_5.Bios
Description | Use this option to configure how the system handles redundant power supply configurations. Balanced Mode shares the power delivery equally between all installed power supplies. All High Efficiency Mode options provide the most power efficient operation with redundant power supplies by keeping half of the power supplies in standby mode at lower power usage levels. The High Efficiency Mode options enable the system to select which power supply to place in standby. Auto enables the system to select between the odd or even power supply based on a semi-random distribution within a group of systems. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
BalancedMode |
Balanced Mode |
HighEfficiencyAuto |
High Efficiency Mode (Auto) |
HighEfficiencyOddStandby |
High Efficiency Mode (Odd Supply Standby) |
HighEfficiencyEvenStandby |
High Efficiency Mode (Even Supply Standby) |
RedundantPowerSupplySystemDomain (Redundant Power Supply Mode - System Domain) Member of Bios.v1_0_5.Bios
Description | Use this option to configure how the system handles redundant power supply configurations. Balanced Mode shares the power delivery equally between all installed power supplies. All High Efficiency Mode options provide the most power efficient operation with redundant power supplies by keeping half of the power supplies in standby mode at lower power usage levels. The High Efficiency Mode options enable the system to select which power supply to place in standby. Auto enables the system to select between the odd or even power supply based on a semi-random distribution within a group of systems. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
BalancedMode |
Balanced Mode |
HighEfficiencyAuto |
High Efficiency Mode (Auto) |
HighEfficiencyOddStandby |
High Efficiency Mode (Odd Supply Standby) |
HighEfficiencyEvenStandby |
High Efficiency Mode (Even Supply Standby) |
RestoreDefaults (Restore Default System Settings) Member of Bios.v1_0_5.Bios
Description | Use this option to reset all configuration settings to their default values. Changes that have been made might be lost. You must reboot the system for changes to take effect. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
No |
No, cancel the restore procedure. |
Yes |
Yes, restore the default settings. |
RestoreManufacturingDefaults (Restore Default Manufacturing Settings) Member of Bios.v1_0_5.Bios
Description | Use this option to reset all configuration settings to their default manufacturing values. Changes that have been made might be lost. If Secure Boot is enabled, related security settings might be lost. You must reboot the system for changes to take effect. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
No |
No, cancel restore procedure. |
Yes |
Yes, restore the default settings. |
RomSelection (ROM Selection) Member of Bios.v1_0_5.Bios
Description | Use this option to revert the server to a previous BIOS ROM image. The backup image is the BIOS ROM image that was used prior to the last flash event. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
CurrentRom |
Use Current ROM |
BackupRom |
Switch to Backup ROM |
SataSanitize (SATA Sanitize) Member of Bios.v1_0_5.Bios
Description | Use this option to control whether sanitize functionality is supported. When enabled, the Sanitize Freeze Lock command is not sent to supported SATA hard drives, enabling sanitize operation to function (the Sanitize command is supported). This option is only supported when the SATA controller is in AHCI mode. Sanitize operation only operates with hard drives that support the sanitize command. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SataSecureErase (SATA Secure Erase) Member of Bios.v1_0_5.Bios
Description | Use this option to control whether Secure Erase functionality is supported. When enabled, the Security Freeze Lock command is not sent to supported SATA hard drives, enabling Secure erase to function (the Secure Erase command is supported). This option is only supported when the SATA controller is in AHCI mode. Secure Erase only operates with hard drives that support the Secure Erase command. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SaveUserDefaults (Save User Defaults) Member of Bios.v1_0_5.Bios
Description | Select this option to save the current settings as the system defaults. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
No |
No, Cancel |
Yes |
Yes, Save |
SciRasSupport (SCI RAS Support) Member of Bios.v1_0_5.Bios
Description | Use this option to select the System Control Interrupt (SCI) signaling mode of operation. This setting can be used to allow how the system will signal the Operating System for certain error conditions. Certain resiliency features, such as Page Retire, require this setting to be set properly to allow the Operating System to properly react to the error event. Please consult documentation for which Operating Systems support which modes of SCI operation. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Ghesv1Support |
GHES v1 Support |
Ghesv2Support |
GHES v2 Support |
SecStartBackupImage (Backup ROM Image Authentication) Member of Bios.v1_0_5.Bios
Description | Use this option to enable cryptographic authentication of the backup ROM image on startup. When this option is disabled, only the primary image is authenticated on each startup. Enable this option to also perform cryptographic authentication of the backup ROM image. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SecureBootStatus (Secure Boot Status) Member of Bios.v1_0_5.Bios
Description | The current state of Secure Boot configuration. |
Type | Enumeration |
Read Only | True |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
SerialConsoleBaudRate (BIOS Serial Console Baud Rate) Member of Bios.v1_0_5.Bios
Description | This is the transfer rate at which data is transmitted through the serial port. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
BaudRate9600 |
9600 |
BaudRate19200 |
19200 |
BaudRate38400 |
38400 |
BaudRate57600 |
57600 |
BaudRate115200 |
115200 |
SerialConsoleEmulation (BIOS Serial Console Emulation Mode) Member of Bios.v1_0_5.Bios
Description | Use this option to select the emulation mode type. The option you select depends on the emulation you want to use in your serial terminal program (such as HyperTerminal or PuTTy). The BIOS emulation mode must match the mode you select in your terminal program. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Vt100 |
VT100 |
Ansi |
ANSI |
Vt100Plus |
VT100+ |
VtUtf8 |
VT-UTF8 |
SerialConsolePort (BIOS Serial Console Port) Member of Bios.v1_0_5.Bios
Description | Use this option to re-direct video and keystrokes through the serial port to OS boot. This option can interfere with non-terminal devices attached to the serial port. In such cases, set this option to disabled. This option is only supported in English language mode when running in the UEFI pre-boot System Utilities. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
Disabled |
Disabled |
Physical |
Physical Serial Port |
Virtual |
Virtual Serial Port |
SerialNumber (Serial Number) Member of Bios.v1_0_5.Bios
Description | Use this option to set the system serial number. This value must always match the serial number sticker located on the chassis. |
Type | String |
Read Only | False |
ServerAssetTag (Server Asset Tag) Member of Bios.v1_0_5.Bios
Description | Select this option to modify the Server Asset Tag text line. |
Type | String |
Read Only | False |
ServerConfigLockStatus (Server Configuration Lock Status) Member of Bios.v1_0_5.Bios
Description | The current state of the Server Configuration Lock feature. |
Type | Enumeration |
Read Only | True |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
ServerName (Server Name) Member of Bios.v1_0_5.Bios
Description | Select this option to modify the server name text line. |
Type | String |
Read Only | False |
ServerOtherInfo (Server Other Information) Member of Bios.v1_0_5.Bios
Description | Use this option to modify the Other Server text line. |
Type | String |
Read Only | False |
ServerPrimaryOs (Server Primary OS) Member of Bios.v1_0_5.Bios
Description | Use this option to modify the Server Primary OS text line. |
Type | String |
Read Only | False |
ServiceEmail (Service Contact E-mail Address) Member of Bios.v1_0_5.Bios
Description | Enter the server service contact e-mail address. |
Type | String |
Read Only | False |
ServiceName (Service Contact Name) Member of Bios.v1_0_5.Bios
Description | Enter the server service contact name text. |
Type | String |
Read Only | False |
ServiceOtherInfo (Service Contact Other Information) Member of Bios.v1_0_5.Bios
Description | Enter the other server service contact information text. |
Type | String |
Read Only | False |
ServicePhone (Service Contact Phone Number) Member of Bios.v1_0_5.Bios
Description | Enter the server service contact phone number text. |
Type | String |
Read Only | False |
SetupBrowserSelection (Setup Browser Selection) Member of Bios.v1_0_5.Bios
Description | Select which setup browser to use: GUI or Text. Auto mode uses text when the user enters RBSU via serial console, and uses GUI via IRC or physical terminal. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
GUI |
GUI |
Text |
Text |
Auto |
Auto |
Slot10MctpBroadcastSupport (PCIe Slot 10 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot10NicBoot1 (Slot 10 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot10NicBoot2 (Slot 10 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot10NicBoot3 (Slot 10 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot10NicBoot4 (Slot 10 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot10NicBoot5 (Slot 10 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot10NicBoot6 (Slot 10 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot10NicBoot7 (Slot 10 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot10NicBoot8 (Slot 10 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot10StorageBoot (PCIe Slot 10) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot11MctpBroadcastSupport (PCIe Slot 11 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot11NicBoot1 (Slot 11 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot11NicBoot2 (Slot 11 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot11NicBoot3 (Slot 11 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot11NicBoot4 (Slot 11 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot11NicBoot5 (Slot 11 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot11NicBoot6 (Slot 11 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot11NicBoot7 (Slot 11 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot11NicBoot8 (Slot 11 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot11StorageBoot (PCIe Slot 11) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot12MctpBroadcastSupport (PCIe Slot 12 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot12NicBoot1 (Slot 12 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot12NicBoot2 (Slot 12 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot12NicBoot3 (Slot 12 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot12NicBoot4 (Slot 12 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot12NicBoot5 (Slot 12 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot12NicBoot6 (Slot 12 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot12NicBoot7 (Slot 12 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot12NicBoot8 (Slot 12 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot12StorageBoot (PCIe Slot 12) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot13MctpBroadcastSupport (PCIe Slot 13 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot13NicBoot1 (Slot 13 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot13NicBoot2 (Slot 13 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot13NicBoot3 (Slot 13 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot13NicBoot4 (Slot 13 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot13NicBoot5 (Slot 13 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot13NicBoot6 (Slot 13 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot13NicBoot7 (Slot 13 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot13NicBoot8 (Slot 13 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot13StorageBoot (PCIe Slot 13) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot14MctpBroadcastSupport (PCIe Slot 14 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot14NicBoot1 (Slot 14 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot14NicBoot2 (Slot 14 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot14NicBoot3 (Slot 14 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot14NicBoot4 (Slot 14 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot14NicBoot5 (Slot 14 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot14NicBoot6 (Slot 14 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot14NicBoot7 (Slot 14 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot14NicBoot8 (Slot 14 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot14StorageBoot (PCIe Slot 14) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot15MctpBroadcastSupport (PCIe Slot 15 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot15NicBoot1 (Slot 15 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot15NicBoot2 (Slot 15 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot15NicBoot3 (Slot 15 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot15NicBoot4 (Slot 15 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot15NicBoot5 (Slot 15 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot15NicBoot6 (Slot 15 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot15NicBoot7 (Slot 15 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot15NicBoot8 (Slot 15 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot15StorageBoot (PCIe Slot 15) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot16MctpBroadcastSupport (PCIe Slot 16 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot16NicBoot1 (Slot 16 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot16NicBoot2 (Slot 16 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot16NicBoot3 (Slot 16 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot16NicBoot4 (Slot 16 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot16NicBoot5 (Slot 16 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot16NicBoot6 (Slot 16 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot16NicBoot7 (Slot 16 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot16NicBoot8 (Slot 16 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot16StorageBoot (PCIe Slot 16) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot17MctpBroadcastSupport (PCIe Slot 17 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot17NicBoot1 (Slot 17 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot17NicBoot2 (Slot 17 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot17NicBoot3 (Slot 17 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot17NicBoot4 (Slot 17 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot17NicBoot5 (Slot 17 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot17NicBoot6 (Slot 17 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot17NicBoot7 (Slot 17 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot17NicBoot8 (Slot 17 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot17StorageBoot (PCIe Slot 17) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot18MctpBroadcastSupport (PCIe Slot 18 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot18NicBoot1 (Slot 18 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot18NicBoot2 (Slot 18 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot18NicBoot3 (Slot 18 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot18NicBoot4 (Slot 18 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot18NicBoot5 (Slot 18 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot18NicBoot6 (Slot 18 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot18NicBoot7 (Slot 18 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot18NicBoot8 (Slot 18 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot18StorageBoot (PCIe Slot 18) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot19MctpBroadcastSupport (PCIe Slot 19 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot19NicBoot1 (Slot 19 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot19NicBoot2 (Slot 19 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot19NicBoot3 (Slot 19 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot19NicBoot4 (Slot 19 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot19NicBoot5 (Slot 19 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot19NicBoot6 (Slot 19 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot19NicBoot7 (Slot 19 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot19NicBoot8 (Slot 19 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot19StorageBoot (PCIe Slot 19) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot1MctpBroadcastSupport (PCIe Slot 1 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot1NicBoot1 (Slot 1 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1NicBoot2 (Slot 1 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1NicBoot3 (Slot 1 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1NicBoot4 (Slot 1 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1NicBoot5 (Slot 1 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1NicBoot6 (Slot 1 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1NicBoot7 (Slot 1 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1NicBoot8 (Slot 1 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot1StorageBoot (PCIe Slot 1) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot20MctpBroadcastSupport (PCIe Slot 20 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot20NicBoot1 (Slot 20 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot20NicBoot2 (Slot 20 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot20NicBoot3 (Slot 20 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot20NicBoot4 (Slot 20 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot20NicBoot5 (Slot 20 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot20NicBoot6 (Slot 20 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot20NicBoot7 (Slot 20 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot20NicBoot8 (Slot 20 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot20StorageBoot (PCIe Slot 20) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot21MctpBroadcastSupport (PCIe Slot 21 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot21NicBoot1 (Slot 21 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot21NicBoot2 (Slot 21 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot21NicBoot3 (Slot 21 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot21NicBoot4 (Slot 21 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot21NicBoot5 (Slot 21 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot21NicBoot6 (Slot 21 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot21NicBoot7 (Slot 21 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot21NicBoot8 (Slot 21 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot21StorageBoot (PCIe Slot 21) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot22MctpBroadcastSupport (PCIe Slot 22 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot22NicBoot1 (Slot 22 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot22NicBoot2 (Slot 22 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot22NicBoot3 (Slot 22 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot22NicBoot4 (Slot 22 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot22NicBoot5 (Slot 22 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot22NicBoot6 (Slot 22 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot22NicBoot7 (Slot 22 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot22NicBoot8 (Slot 22 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot22StorageBoot (PCIe Slot 22) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot23MctpBroadcastSupport (PCIe Slot 23 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot23StorageBoot (PCIe Slot 23) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot2MctpBroadcastSupport (PCIe Slot 2 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot2NicBoot1 (Slot 2 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2NicBoot2 (Slot 2 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2NicBoot3 (Slot 2 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2NicBoot4 (Slot 2 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2NicBoot5 (Slot 2 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2NicBoot6 (Slot 2 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2NicBoot7 (Slot 2 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2NicBoot8 (Slot 2 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot2StorageBoot (PCIe Slot 2) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot3MctpBroadcastSupport (PCIe Slot 3 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot3NicBoot1 (Slot 3 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3NicBoot2 (Slot 3 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3NicBoot3 (Slot 3 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3NicBoot4 (Slot 3 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3NicBoot5 (Slot 3 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3NicBoot6 (Slot 3 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3NicBoot7 (Slot 3 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3NicBoot8 (Slot 3 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot3StorageBoot (PCIe Slot 3) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot4MctpBroadcastSupport (PCIe Slot 4 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot4NicBoot1 (Slot 4 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4NicBoot2 (Slot 4 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4NicBoot3 (Slot 4 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4NicBoot4 (Slot 4 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4NicBoot5 (Slot 4 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4NicBoot6 (Slot 4 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4NicBoot7 (Slot 4 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4NicBoot8 (Slot 4 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot4StorageBoot (PCIe Slot 4) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot5MctpBroadcastSupport (PCIe Slot 5 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot5NicBoot1 (Slot 5 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5NicBoot2 (Slot 5 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5NicBoot3 (Slot 5 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5NicBoot4 (Slot 5 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5NicBoot5 (Slot 5 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5NicBoot6 (Slot 5 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5NicBoot7 (Slot 5 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5NicBoot8 (Slot 5 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot5StorageBoot (PCIe Slot 5) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot6MctpBroadcastSupport (PCIe Slot 6 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot6NicBoot1 (Slot 6 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6NicBoot2 (Slot 6 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6NicBoot3 (Slot 6 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6NicBoot4 (Slot 6 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6NicBoot5 (Slot 6 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6NicBoot6 (Slot 6 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6NicBoot7 (Slot 6 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6NicBoot8 (Slot 6 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot6StorageBoot (PCIe Slot 6) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot7MctpBroadcastSupport (PCIe Slot 7 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot7NicBoot1 (Slot 7 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot7NicBoot2 (Slot 7 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot7NicBoot3 (Slot 7 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot7NicBoot4 (Slot 7 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot7StorageBoot (PCIe Slot 7) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot8MctpBroadcastSupport (PCIe Slot 8 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot8NicBoot1 (Slot 8 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot8NicBoot2 (Slot 8 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot8NicBoot3 (Slot 8 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot8NicBoot4 (Slot 8 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot8StorageBoot (PCIe Slot 8) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
Slot9MctpBroadcastSupport (PCIe Slot 9 MCTP Broadcast Support) Member of Bios.v1_0_5.Bios
Description | Use this option to control the PCIe Management Component Transport Protocol (MCTP) Support for a given slot. This option can be used to disable MCTP support to a given PCIe endpoint that may not properly support this protocol. It is recommended that this option remain enabled for full system functionality. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Slot9NicBoot1 (Slot 9 NIC Port 1 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot9NicBoot2 (Slot 9 NIC Port 2 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot9NicBoot3 (Slot 9 NIC Port 3 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot9NicBoot4 (Slot 9 NIC Port 4 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot9NicBoot5 (Slot 9 NIC Port 5 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot9NicBoot6 (Slot 9 NIC Port 6 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot9NicBoot7 (Slot 9 NIC Port 7 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot9NicBoot8 (Slot 9 NIC Port 8 Boot) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable network boot (PXE, iSCSI or UEFI HTTP) for the selected NIC. You might need to configure the NIC firmware for the boot option to be active. This is applicable only in UEFI Boot Mode. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NetworkBoot |
Network Boot |
Disabled |
Disabled |
Slot9StorageBoot (PCIe Slot 9) Member of Bios.v1_0_5.Bios
Description | When Boot All Targets is selected, all valid boot targets attached to the storage controller are made available in the UEFI Boot Order list. If Boot No Targets is selected, no boot targets from this storage controller are made available in the UEFI Boot Order.If Boot Limit to 32 Targets is selected, 32 boot targets attached to the storage controller are made available in the UEFI Boot Order. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
AllTargets |
Boot All Targets |
ThirtyTwoTargets |
Boot Limit to 32 Targets |
NoTargets |
Boot No Targets |
SpeculativeLockScheduling (Page Table Entry Speculative Lock Scheduling ) Member of Bios.v1_0_5.Bios
Description | Disabling this forces Page Table Entry locks to only be scheduled non-speculatively. Disabling this feature will impact performance |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
Sriov (SR-IOV) Member of Bios.v1_0_5.Bios
Description | If enabled, SR-IOV support enables a hypervisor to create virtual instances of a PCI-express device, potentially increasing performance. If enabled, the BIOS allocates additional resources to PCI-express devices. You can leave this option set to enabled even if you are not using a hypervisor. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
TPM2EndorsementDisable (TPM 2.0 Endorsement Hierarchy) Member of Bios.v1_0_5.Bios
Description | Use this option to enable/disable the TPM 2.0 Endorsement Hierarchy. When the TPM 2.0 Endorsement Hierarchy is disabled, certain TPM functionality under the operating system may not operate properly. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
TPM2StorageDisable (TPM 2.0 Storage Hierarchy) Member of Bios.v1_0_5.Bios
Description | Use this option to enable/disable the TPM 2.0 Storage Hierarchy. When the TPM 2.0 Storage Hierarchy is disabled, certain TPM functionality under the operating system may not operate properly. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
ThermalConfig (Thermal Configuration) Member of Bios.v1_0_5.Bios
Description | Use this option to select the fan cooling solution for the system. Optimal Cooling provides the most efficient solution by configuring fan speeds to the minimum required speed to provide adequate cooling. Increased Cooling runs fans at higher speeds to provide additional cooling. Select Increased Cooling when third-party storage controllers are cabled to the embedded hard drive cage, or if the system is experiencing thermal issues that cannot be resolved. Maximum cooling provides the maximum cooling available on this platform. Enhanced CPU Cooling runs the fans at a higher speed to provide additional cooling to the processors. Selecting Enhanced CPU Cooling may improve system performance with certain processor intensive workloads. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
OptimalCooling |
Optimal Cooling |
IncreasedCooling |
Increased Cooling |
MaxCooling |
Maximum Cooling |
EnhancedCPUCooling |
Enhanced CPU Cooling |
ThermalShutdown (Thermal Shutdown) Member of Bios.v1_0_5.Bios
Description | Use this option to control the reaction of the system to caution level thermal events. When disabled, the System Management Firmware ignores thermal events, and the system immediately powers off in data-destructive situations. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
TimeFormat (Time Format) Member of Bios.v1_0_5.Bios
Description | This option controls how the system time is stored in the hardware Real Time Clock (RTC). When configured to ‘Coordinated Universal Time (UTC)’ (default) the local time is calculated from the associated time zone value. When configured to ‘Local Time’ the time is stored directly as local time and the time zone option does not have meaning. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Local |
Local Time |
Utc |
Coordinated Universal Time (UTC) |
TimeZone (Time Zone) Member of Bios.v1_0_5.Bios
Description | This option displays the current time zone setting for the system. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
UtcM12 |
UTC-12:00, International Date Line West |
UtcM11 |
UTC-11:00, Midway Island, Samoa |
UtcM10 |
UTC-10:00, Hawaii |
UtcM930 |
UTC-09:30, Marquesas |
UtcM9 |
UTC-09:00, Alaska |
UtcM8 |
UTC-08:00, Pacific Time(US & Canada), Tijuana, Portland |
UtcM7 |
UTC-07:00, Arizona, Chihuahua, La Paz, Mazatlan, Mountain Time (US & Canada) |
UtcM6 |
UTC-06:00, Central America, Central Time(US & Canada) |
UtcM5 |
UTC-05:00, Bogota, Lima, Quito, Eastern Time(US & Canada) |
UtcM4 |
UTC-04:00, Atlantic Time(Canada), Caracas, Santiago, Georgetown |
UtcM330 |
UTC-03:30, Newfoundland |
UtcM3 |
UTC-03:00, Brasilia, Buenos Aires, Greenland |
UtcM2 |
UTC-02:00, Mid-Atlantic |
UtcM1 |
UTC-01:00, Azores, Cape Verde Is. |
Utc0 |
UTC-00:00, Greenwich Mean Time, Casablanca, Monrovia, Dublin, London |
UtcP1 |
UTC+01:00, Amsterdam, Berlin, Bern, Rome, Paris, West Central Africa |
UtcP2 |
UTC+02:00, Athens, Bucharest, Cairo, Jerusalem |
UtcP3 |
UTC+03:00, Baghdad, Kuwait, Riyadh, Moscow, Nairobi, Istanbul |
UtcP330 |
UTC+03:30, Tehran |
UtcP4 |
UTC+04:00, Abu Dhabi, Muscat, Baku, Tbilisi, Yerevan |
UtcP430 |
UTC+04:30, Kabul |
UtcP5 |
UTC+05:00, Ekaterinburg, Islamabad, Karachi, Tashkent |
UtcP530 |
UTC+05:30, Chennai, Kolkata, Mumbai, New Delhi |
UtcP545 |
UTC+05:45, Kathmandu |
UtcP6 |
UTC+06:00, Almaty, Astana, Dhaka, Sri Jayawardenepura |
UtcP630 |
UTC+06:30, Rangoon |
UtcP7 |
UTC+07:00, Bangkok, Hanoi, Jakarta, Krasnoyarsk, Novosibirsk |
UtcP8 |
UTC+08:00, Beijing, Chongqing, Hong Kong, Urumqi, Taipei, Perth |
UtcP845 |
UTC+08:45, Eucla |
UtcP9 |
UTC+09:00, Osaka, Sapporo, Tokyo, Seoul, Yakutsk |
UtcP930 |
UTC+09:30, Adelaide, Darwin |
UtcP10 |
UTC+10:00, Canberra, Melbourne, Sydney, Guam, Hobart, Vladivostok |
UtcP1030 |
UTC+10:30, Lord Howe |
UtcP1045 |
UTC+10:45, Chatham |
UtcP11 |
UTC+11:00, Magadan, Solomon Is., New Caledonia |
UtcP12 |
UTC+12:00, Auckland, Wellington, Fiji, Kamchatka, Marshall Is. |
UtcP13 |
UTC+13:00, Nuku'alofa |
UtcP14 |
UTC+14:00, Line Islands |
Unspecified |
Unspecified Time Zone |
Tpm20SoftwareInterfaceStatus (Current TPM 2.0 Software Interface Status) Member of Bios.v1_0_5.Bios
Description | Current TPM 2.0 Software Interface Status: FIFO or CRB. |
Type | Enumeration |
Read Only | True |
Value | Description |
---|---|
NoAction |
No Action |
Fifo |
FIFO interface |
Tpm2Operation (TPM 2.0 Operation) Member of Bios.v1_0_5.Bios
Description | Use this option to perform a clear operation on the TPM. Clearing the TPM can prevent the server from booting to a TPM-aware operating system if the operating system uses TPM’s measurements. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NoAction |
No Action |
Clear |
Clear |
TpmActivePcrs (Current TPM 2.0 Active PCRs) Member of Bios.v1_0_5.Bios
Description | Current TPM 2.0 Active PCRs: SHA1, SHA256, SHA384, SHA1_SHA256, or SHA256_SHA384 |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
NotSpecified |
Not specified |
Sha1 |
SHA1 only |
Sha256 |
SHA256 only |
Sha384 |
SHA384 only |
Sha1Sha256 |
SHA1 and SHA256 |
Sha256Sha384 |
SHA256 and SHA384 |
TpmChipId (Current TPM Chip ID) Member of Bios.v1_0_5.Bios
Description | Current TPM Chip |
Type | Enumeration |
Read Only | True |
Value | Description |
---|---|
None |
None |
StMicroGen10 |
ST Micro Gen10 |
STMicroGen10Plus |
ST Micro Gen10 Plus |
STMicroGen11 |
ST Micro Gen11 |
TpmState (Current TPM State) Member of Bios.v1_0_5.Bios
Description | Current TPM device state: Not Present; Present and Disabled; Present and Enabled. |
Type | Enumeration |
Read Only | True |
Value | Description |
---|---|
NotPresent |
Not Present |
PresentDisabled |
Present and Disabled |
PresentEnabled |
Present and Enabled |
TpmUefiOpromMeasuring (TPM UEFI Option ROM Measurement) Member of Bios.v1_0_5.Bios
Description | Use this option to enable measuring the UEFI PCI option ROMs. Disabling this option skips measuring the UEFI PCI option ROMs. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
TpmVisibility (TPM Visibility) Member of Bios.v1_0_5.Bios
Description | Use this option to hide the TPM from the operating system. When the TPM is hidden, BIOS secure startup is disabled, and the TPM does not respond to any commands. Intended use is for removing the TPM option from the system without removing the actual hardware.This option will also disable the TPM 2.0 (if active) Platform, Storage and Endorsement Hierarchies. This option is grayed out when Platform Certificate Support is enabled. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Hidden |
Hidden |
Visible |
Visible |
TransparentSecureMemoryEncryption (Transparent Secure Memory Encryption) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable TSME |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UefiSerialDebugLevel (UEFI Serial Debug Message Level) Member of Bios.v1_0_5.Bios
Description | Use this option to enable UEFI Serial Debug output and verbosity level. Selecting Verbose can impact server boot time significantly. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
ErrorsOnly |
Errors Only |
Medium |
Medium |
Network |
Network |
Verbose |
Verbose |
Custom |
Custom |
UefiShellBootOrder (Add Embedded UEFI Shell to Boot Order) Member of Bios.v1_0_5.Bios
Description | When enabled, this option adds the Embedded UEFI Shell as an entry in the UEFI Boot Order list. This option is only available when the Embedded UEFI Shell is enabled. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UefiShellPhysicalPresenceKeystroke (Physical Presence with Keystroke) Member of Bios.v1_0_5.Bios
Description | Use the option to enable or disable Physical Presence with Keystroke. If enabled, a countdown starts after entering Embedded UEFI Shell and stops when a keystroke is detected. If no keystroke is detected by the end of the countdown, or if the option is disabled, certain configuration actions are prevented. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UefiShellScriptVerification (Shell Script Verification) Member of Bios.v1_0_5.Bios
Description | Enable this option to allow verification of UEFI shell script files when Secure Boot is enabled. For successful execution of script, make sure that UEFI shell scripts are enrolled in the Secure Boot database (db). |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UefiShellStartup (UEFI Shell Script Auto-Start) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable automatic execution of the Embedded UEFI Shell startup script. You can store the script file on local media or access it from a network location. You must name the script file “startup.nsh” and place it on local media or a network location accessible to the server. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UefiShellStartupLocation (Shell Auto-Start Script Location) Member of Bios.v1_0_5.Bios
Description | Use this option to select the location of the Embedded UEFI Shell startup script. For the ‘File Systems on Attached Media’ option, you must name the script file “startup.nsh” and place it on a UEFI accessible local file system, such as a FAT32 partition on a USB disk or HDD. For the ‘Network Location’ option, the file must end with a .nsh extension, and must be placed at an HTTP/HTTPS or FTP location accessible to the system. When you select the ‘Auto’ option, the system attempts to retrieve the startup script from the network location first, followed by locally attached media. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
AttachedMedia |
File Systems on Attached Media |
NetworkLocation |
Network Location |
UefiShellStartupUrl (Network Location for Shell Auto-Start Script) Member of Bios.v1_0_5.Bios
Description | Use this option to configure a network URL to a UEFI Shell startup script. This option is available and used only when the Auto-Start Script Location is set to ‘Network Location’, or ‘Auto’, and the Shell Auto-Start Script discovery using DHCP is set to ‘Disabled’. URLs in HTTP/HTTPS are accepted using either an IPv4 or IPv6 server address, or using a host name. FTP formats are accepted using either an IPv4 server address or a host name. For example, the URLs can be in any of the following formats: http://192.168.0.1/file/file.nsh, http://example.com/file/file.nsh, https://example.com/file/file.nsh, http://[1234::1000]/file.nsh. The file must end with an .nsh extension. When configured, the Embedded UEFI Shell attempts to load and execute the startup script from the network location pointed to by this URL. When an HTTPS URL is configured, you must enroll the respective HTTPS server’s TLS certificate under Server Security > TLS(HTTPS) Options. |
Type | String |
Read Only | False |
UefiShellStartupUrlFromDhcp (Discover Shell Auto-Start Script using DHCP) Member of Bios.v1_0_5.Bios
Description | Use this option to let the Shell discover its startup script URL using DHCP. This option is available only if the ‘HTTP Support’ policy is not set to ‘Disabled’ and Auto-Start Script Location is set to ‘Network Location’, or ‘Auto’. When set to ‘Enabled’, the Shell sends DHCP requests with the DHCP User Class option set to the string ‘UEFIShell’. The DHCP server must be configured to provide HTTP/HTTPS or FTP URLs when this DHCP User Class string is present in the DHCP request. The User Class option is Option 77 when using DHCP over IPv4, and Option 15 when using DHCP over IPv6. URLs in HTTP/HTTPS must use either an IPv4 or IPv6 server address, or a host name. FTP formats are accepted using either an IPv4 server address or a host name. The URL provided by the DHCP server should match the ‘HTTP Support’ policy. When ‘HTTP Support’ policy is set to ‘Auto’, any HTTP/HTTPS or FTP URL provided by the DHCP server is used. When policy is set to ‘HTTPS only’, only HTTPS URLs are used, and other URLs are ignored. When policy is set to ‘HTTP only’, only HTTP or FTP URLs are used, and other URLs are ignored. When policy is set to ‘Disabled’, the Shell does not send any DHCP request. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UefiVariableAccessFwControl (UEFI Variable Access Firmware Control) Member of Bios.v1_0_5.Bios
Description | Use this option to allow the system BIOS to completely control certain UEFI variables from being written to by other software such as an Operating System. When Disabled is selected, all UEFI variables are writable. When Enabled is selected, all changes made by software other than the system BIOS to critical UEFI variables will be blocked. For instance, new boot options the Operating System attempt to add to the top of BootOrder will actually be placed at the bottom of the BootOrder. Note: When UEFI Variable Access Firmware Control is Enabled, some Operating System functionality may not work as expected. Errors may occur while installing a new Operating System. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Disabled |
Disabled |
Enabled |
Enabled |
UrlBootFile (Boot from URL 1) Member of Bios.v1_0_5.Bios
Description | Use this option to configure a network URL to a bootable ISO or EFI file. URLs in HTTP/HTTPS are accepted using either an IPv4 or IPv6 server address, or using a host name. For example, the URLs can be in any of the following formats: http://192.168.0.1/file/image.iso, http://example.com/file/image.efi, https://example.com/file/image.efi, http://[1234::1000]/image.iso. When configured, this URL is listed as a boot option in the UEFI boot menu. Selecting this boot option downloads the file to the system memory, and configures the system to attempt to boot from it. There is no specific ordering on this option. It can be independently ordered in the boot menu. This setting requires configuring the ‘Pre-Boot Network Interface’ option if you want to access the URL location through a specific network interface. When an HTTPS URL is configured, this setting requires enrolling the respective TLS certificate of the HTTPS server under Server Security > TLS(HTTPS) Options. This option uses the IP address settings configured in this page. This is only applicable in UEFI Mode. Note: Booting from an ISO file can involve only booting a preliminary OS environment image, such as WinPE or a mini Linux, or a complete OS install image if the OS supports the HTTP Boot feature (Old OS versions may not support this). Please check your OS documentation for the HTTP Boot feature support. |
Type | String |
Read Only | False |
UrlBootFile2 (Boot from URL 2) Member of Bios.v1_0_5.Bios
Description | Use this option to configure a network URL to a bootable ISO or EFI file. URLs in HTTP/HTTPS are accepted using either an IPv4 or IPv6 server address, or using a host name. For example, the URLs can be in any of the following formats: http://192.168.0.1/file/image.iso, http://example.com/file/image.efi, https://example.com/file/image.efi, http://[1234::1000]/image.iso. When configured, this URL is listed as a boot option in the UEFI boot menu. Selecting this boot option downloads the file to the system memory, and configures the system to attempt to boot from it. There is no specific ordering on this option. It can be independently ordered in the boot menu. This setting requires configuring the ‘Pre-Boot Network Interface’ option if you want to access the URL location through a specific network interface. When an HTTPS URL is configured, this setting requires enrolling the respective TLS certificate of the HTTPS server under Server Security > TLS(HTTPS) Options. This option uses the IP address settings configured in this page. This is only applicable in UEFI Mode. Note: Booting from an ISO file can involve only booting a preliminary OS environment image, such as WinPE or a mini Linux, or a complete OS install image if the OS supports the HTTP Boot feature (Old OS versions may not support this). Please check your OS documentation for the HTTP Boot feature support. |
Type | String |
Read Only | False |
UrlBootFile3 (Boot from URL 3) Member of Bios.v1_0_5.Bios
Description | Use this option to configure a network URL to a bootable ISO or EFI file. URLs in HTTP/HTTPS are accepted using either an IPv4 or IPv6 server address, or using a host name. For example, the URLs can be in any of the following formats: http://192.168.0.1/file/image.iso, http://example.com/file/image.efi, https://example.com/file/image.efi, http://[1234::1000]/image.iso. When configured, this URL is listed as a boot option in the UEFI boot menu. Selecting this boot option downloads the file to the system memory, and configures the system to attempt to boot from it. There is no specific ordering on this option. It can be independently ordered in the boot menu. This setting requires configuring the ‘Pre-Boot Network Interface’ option if you want to access the URL location through a specific network interface. When an HTTPS URL is configured, this setting requires enrolling the respective TLS certificate of the HTTPS server under Server Security > TLS(HTTPS) Options. This option uses the IP address settings configured in this page. This is only applicable in UEFI Mode. Note: Booting from an ISO file can involve only booting a preliminary OS environment image, such as WinPE or a mini Linux, or a complete OS install image if the OS supports the HTTP Boot feature (Old OS versions may not support this). Please check your OS documentation for the HTTP Boot feature support. |
Type | String |
Read Only | False |
UrlBootFile4 (Boot from URL 4) Member of Bios.v1_0_5.Bios
Description | Use this option to configure a network URL to a bootable ISO or EFI file. URLs in HTTP/HTTPS are accepted using either an IPv4 or IPv6 server address, or using a host name. For example, the URLs can be in any of the following formats: http://192.168.0.1/file/image.iso, http://example.com/file/image.efi, https://example.com/file/image.efi, http://[1234::1000]/image.iso. When configured, this URL is listed as a boot option in the UEFI boot menu. Selecting this boot option downloads the file to the system memory, and configures the system to attempt to boot from it. There is no specific ordering on this option. It can be independently ordered in the boot menu. This setting requires configuring the ‘Pre-Boot Network Interface’ option if you want to access the URL location through a specific network interface. When an HTTPS URL is configured, this setting requires enrolling the respective TLS certificate of the HTTPS server under Server Security > TLS(HTTPS) Options. This option uses the IP address settings configured in this page. This is only applicable in UEFI Mode. Note: Booting from an ISO file can involve only booting a preliminary OS environment image, such as WinPE or a mini Linux, or a complete OS install image if the OS supports the HTTP Boot feature (Old OS versions may not support this). Please check your OS documentation for the HTTP Boot feature support. |
Type | String |
Read Only | False |
UsbBoot (USB Boot Support) Member of Bios.v1_0_5.Bios
Description | Set this option to disabled to prevent the system from booting to any USB devices connected to the server. This includes preventing boot to virtual media devices, and the embedded SD or uSD card (if supported). If this option is disabled, firmware updates from OneView will not work. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UsbControl (USB Control) Member of Bios.v1_0_5.Bios
Description | All USB Ports Enabled: Enables all USB ports and embedded devices.All USB Ports Disabled: Disables all USB ports and embedded devices.External USB Ports Disabled: Disables only external USB ports.Internal USB Ports Disabled: Disables only internal USB ports. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
UsbEnabled |
All USB Ports Enabled |
UsbDisabled |
All USB Ports Disabled |
ExternalUsbDisabled |
External USB Ports Disabled |
InternalUsbDisabled |
Internal USB Ports Disabled |
UserDefaultsState (User Defaults) Member of Bios.v1_0_5.Bios
Description | Displays whether user default settings are enabled or disabled. |
Type | Enumeration |
Read Only | True |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
UtilityLang (Utility Language) Member of Bios.v1_0_5.Bios
Description | Select this option to adjust the current language for the system. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
English |
English |
Japanese |
Japanese |
Chinese |
Chinese |
VideoOptions (Video Options) Member of Bios.v1_0_5.Bios
Description | Use this option to configure video settings in the system. When set to Add-in Video Enabled, Embedded Video Disabled, the system only displays video to the first discovered add-in video controller. When set to Both Add-in and Embedded Video Enabled, the system displays video to both the embedded and the first discovered add-in video controllers. In both modes, early system startup video is displayed to the embedded video controller. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
OptionalVideoOnly |
Add-in Video Enabled, Embedded Video Disabled |
BothVideoEnabled |
Both Add-in and Embedded Video Enabled |
VirtualInstallDisk (Virtual Install Disk) Member of Bios.v1_0_5.Bios
Description | Use this option to control the Virtual Install Disk. The Virtual Install Disk contains drivers specific to this server that an OS can use during installation. If enabled, the Virtual Install Disk appears as a drive in the operating system. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
VirtualSerialPort (Virtual Serial Port) Member of Bios.v1_0_5.Bios
Description | Use this option to assign the logical COM port address and associated default resources used by the Virtual Serial Port (VSP). VSP enables the Management Processor to present an emulated serial port to support the BIOS Serial Console and operating system serial console. Note: VSP and Embedded Serial Port cannot be set to the same port. If VSP is changed to the same port as Embedded Serial Port, the Embedded Serial Port will automatically be reassigned. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Com1Irq4 |
COM 1; IRQ4; I/O: 3F8h-3FFh |
Com2Irq3 |
COM 2; IRQ3; I/O: 2F8h-2FFh |
Disabled |
Disabled |
VlanControl (VLAN Control) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable VLAN tagging on all enabled network interfaces. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
VlanId (VLAN ID) Member of Bios.v1_0_5.Bios
Description | Use this option to set the global VLAN ID for all enabled network interfaces. Valid values are 0 to 4094.A value of 0 sets the device to send untagged frames. |
Type | Integer |
Read Only | False |
VlanPriority (VLAN Priority) Member of Bios.v1_0_5.Bios
Description | Use this option to set the priority for the VLAN tagged frames. Valid values are 0 to 7. |
Type | Integer |
Read Only | False |
WakeOnLan (Wake-On LAN) Member of Bios.v1_0_5.Bios
Description | You can configure the server to be powered on remotely when it receives a special packet. This option requires a NIC, NIC driver, and operating system that are WOL-capable. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
WorkloadProfile (Workload Profile) Member of Bios.v1_0_5.Bios
Description | Select this option to change the Workload Profile to accommodate your desired workload. Settings that are changed by the Workload Profile are grayed out and unchangeable unless in the ‘Custom’ profile. Please refer to the ‘UEFI Workload-based Performance Tuning Guide’ for details on which profiles affect which options. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
GeneralPowerEfficientCompute |
General Power Efficient Compute |
GeneralPeakFrequencyCompute |
General Peak Frequency Compute |
GeneralThroughputCompute |
General Throughput Compute |
Virtualization-PowerEfficient |
Virtualization - Power Efficient |
Virtualization-MaxPerformance |
Virtualization - Max Performance |
LowLatency |
Low Latency |
MissionCritical |
Mission Critical |
TransactionalApplicationProcessing |
Transactional Application Processing |
HighPerformanceCompute(HPC) |
High Performance Compute (HPC) |
DecisionSupport |
Decision Support |
GraphicProcessing |
Graphic Processing |
I/OThroughput |
I/O Throughput |
Custom |
Custom |
XGMIForceLinkWidth (XGMI Force Link Width) Member of Bios.v1_0_5.Bios
Description | XGMI Force Link Width setting forces the XGMI link width to a value set by the user. Auto will use the system default setting. Other options will force the user setting to be used. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
x4 |
x4 |
x8 |
x8 |
x16 |
x16 |
XGMIMaxLinkWidth (XGMI Max Link Width) Member of Bios.v1_0_5.Bios
Description | XGMI Max Link Width setting sets the maximum XGMI link width to a value set by the user. Auto will use the system default setting. Other options will force the user setting to be used. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Auto |
Auto |
x4 |
x4 |
x8 |
x8 |
x16 |
x16 |
iSCSISoftwareInitiator (iSCSI Software Initiator) Member of Bios.v1_0_5.Bios
Description | Use this option to enable or disable the iSCSI Software Initiator. When enabled, the system’s iSCSI Software Initiator will be used to access iSCSI targets on any configured NIC ports. When disabled, the system’s iSCSI Software Initiator will not attempt to access any configured iSCSI targets. |
Type | Enumeration |
Read Only | False |
Value | Description |
---|---|
Enabled |
Enabled |
Disabled |
Disabled |
BootOption.v1_0_1.BootOption
@odata.type: "#BootOption.v1_0_1.BootOption"
This is the schema definition for the BootOption resource. It represents the properties of a bootable device available in the System.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bootoptions/{item} |
GET |
Alias
Member of BootOption.v1_0_1.BootOption
Description | The alias of this Boot Source. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
BootOptionEnabled
Member of BootOption.v1_0_1.BootOption
Description | A flag that shows if the Boot Option is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
BootOptionReference
Member of BootOption.v1_0_1.BootOption
Description | The unique boot option string that is referenced in the BootOrder. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
DisplayName
Member of BootOption.v1_0_1.BootOption
Description | The user-readable display string of the Boot Option. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
UefiDevicePath
Member of BootOption.v1_0_1.BootOption
Description | The UEFI device path used to access this UEFI Boot Option. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
BootOptionCollection.BootOptionCollection
@odata.type: "#BootOptionCollection.BootOptionCollection"
A Collection of BootOption resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bootoptions |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
BootOption |
Members (array)
Member of BootOptionCollection.BootOptionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of BootOptionCollection.BootOptionCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of BootOptionCollection.BootOptionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Certificate.v1_6_0.Certificate
@odata.type: "#Certificate.v1_6_0.Certificate"
The Certificate resource describes an X509 certificate.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/externalaccountproviders/ldap/certificates/{item} |
GET PATCH DELETE |
/redfish/v1/managers/{item}/securityservice/iloidevid/certificates/{item} |
GET |
/redfish/v1/managers/{item}/securityservice/iloldevid/certificates/{item} |
GET POST DELETE |
/redfish/v1/managers/{item}/securityservice/platformcert/certificates/{item} |
GET |
/redfish/v1/managers/{item}/securityservice/systemiak/certificates/{item} |
GET |
/redfish/v1/managers/{item}/securityservice/systemidevid/certificates/{item} |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/db/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbdefault/certificates/{item} |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault/certificates/{item} |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault/certificates/{item} |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault/certificates/{item} |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kek/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kekdefault/certificates/{item} |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/pk/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/pkdefault/certificates/{item} |
GET |
CertificateString
Member of Certificate.v1_6_0.Certificate
Description | Contains PEM formatted X509 certificate or PKCS7 certificate chain (Base64 encoded). |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | text |
CertificateType
Member of Certificate.v1_6_0.Certificate
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
PEM |
A PEM encoded certificate. |
PKCS7 |
A PEM encoded PKCS7 certificate. |
Issuer
Issuer.City Member of Certificate.v1_6_0.Certificate
Description | The city or locality of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Issuer.CommonName Member of Certificate.v1_6_0.Certificate
Description | The fully qualified domain name of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Issuer.Country Member of Certificate.v1_6_0.Certificate
Description | The country of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Issuer.DisplayString Member of Certificate.v1_6_0.Certificate
Description | A human-readable string for this identifier. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Issuer.Email Member of Certificate.v1_6_0.Certificate
Description | The email address of the contact within the organization of the entity. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Issuer.Organization Member of Certificate.v1_6_0.Certificate
Description | The name of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Issuer.OrganizationalUnit Member of Certificate.v1_6_0.Certificate
Description | The name of the unit or division of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Issuer.State Member of Certificate.v1_6_0.Certificate
Description | The state, province, or region of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
SerialNumber
Member of Certificate.v1_6_0.Certificate
Description | The serial number that the Certificate Authority assigned to the certificate. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Subject
Subject.City Member of Certificate.v1_6_0.Certificate
Description | The city or locality of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Subject.CommonName Member of Certificate.v1_6_0.Certificate
Description | The fully qualified domain name of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Subject.Country Member of Certificate.v1_6_0.Certificate
Description | The country of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Subject.DisplayString Member of Certificate.v1_6_0.Certificate
Description | A human-readable string for this identifier. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Subject.Email Member of Certificate.v1_6_0.Certificate
Description | The email address of the contact within the organization of the entity. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Subject.Organization Member of Certificate.v1_6_0.Certificate
Description | The name of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Subject.OrganizationalUnit Member of Certificate.v1_6_0.Certificate
Description | The name of the unit or division of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Subject.State Member of Certificate.v1_6_0.Certificate
Description | The state, province, or region of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
UefiSignatureOwner
Member of Certificate.v1_6_0.Certificate
Description | The UEFI signature owner for this certificate. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ValidNotAfter
Member of Certificate.v1_6_0.Certificate
Description | The date on which the certificate validity period ends. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
ValidNotBefore
Member of Certificate.v1_6_0.Certificate
Description | The date on which the certificate validity period begins. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
CertificateCollection.CertificateCollection
@odata.type: "#CertificateCollection.CertificateCollection"
A Collection of Certificate resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/externalaccountproviders/ldap/certificates |
GET POST |
/redfish/v1/managers/{item}/securityservice/iloidevid/certificates |
GET |
/redfish/v1/managers/{item}/securityservice/iloldevid/certificates |
GET POST |
/redfish/v1/managers/{item}/securityservice/platformcert/certificates |
GET |
/redfish/v1/managers/{item}/securityservice/systemiak/certificates |
GET |
/redfish/v1/managers/{item}/securityservice/systemidevid/certificates |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/db/certificates |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbdefault/certificates |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr/certificates |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault/certificates |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt/certificates |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault/certificates |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx/certificates |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault/certificates |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kek/certificates |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kekdefault/certificates |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/pk/certificates |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/pkdefault/certificates |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Certificate |
Members (array)
Member of CertificateCollection.CertificateCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of CertificateCollection.CertificateCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of CertificateCollection.CertificateCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CertificateLocations.v1_0_2.CertificateLocations
@odata.type: "#CertificateLocations.v1_0_2.CertificateLocations"
The CertificateLocations schema describes a Resource that an administrator can use in order to locate all certificates installed on a given service.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/certificateservice/certificatelocations |
GET |
CertificateService.v1_0_3.CertificateService
@odata.type: "#CertificateService.v1_0_3.CertificateService"
The CertificateService schema describes a certificate service that represents the actions available to manage certificates and links to the certificates.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/certificateservice |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Links/CertificateLocations |
CertificateLocations |
CertificateLocations
The information about the location of certificates.
CertificateLocations is a link ("@odata.id": URI
) to another resource.
Actions
CertificateService.GenerateCSR Member of CertificateService.v1_0_3.CertificateService
Parameters:
City (string)
The city or locality of the organization making the request.
GivenName (string)
The given name of the user making the request.
KeyPairAlgorithm (string)
The type of key-pair for use with signing algorithms.
CertificateCollection (object)
The link to the certificate collection where the certificate is installed after the certificate authority (CA) signs the certificate.
Country (string)
The two-letter country code of the organization making the request.
KeyCurveId (string)
The curve ID to use with the key, if needed based on the KeyPairAlgorithm parameter value.
CommonName (string)
The fully qualified domain name of the component to secure.
State (string)
The state, province, or region of the organization making the request.
ContactPerson (string)
The name of the user making the request.
Email (string)
The email address of the contact within the organization making the request.
Surname (string)
The surname of the user making the request.
KeyUsage (array)
The usage of the key contained in the certificate.
UnstructuredName (string)
The unstructured name of the subject.
KeyBitLength (integer)
The length of the key, in bits, if needed based on the KeyPairAlgorithm parameter value.
Organization (string)
The name of the organization making the request.
AlternativeNames (array)
The additional host names of the component to secure.
ChallengePassword (string)
The challenge password to apply to the certificate for revocation requests.
OrganizationalUnit (string)
The name of the unit or division of the organization making the request.
Initials (string)
The initials of the user making the request.
Chassis.v1_19_0.Chassis
@odata.type: "#Chassis.v1_19_0.Chassis"
The Chassis resource describes the physical components for a system. This object represents rack mount servers, blades, and all other containers. The non-CPU/device-centric parts of the schema are accessed either directly or indirectly through this resource.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item} |
GET POST PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Links/ComputerSystems[] |
ComputerSystem |
Links/ManagedBy[] |
Manager |
Oem/Hpe/Links/Devices |
Collection of HpeServerDevice |
NetworkAdapters |
Collection of NetworkAdapter |
Power |
Power |
Thermal |
Thermal |
Links/Drives[] |
Drive |
AssetTag
Member of Chassis.v1_19_0.Chassis
Description | The chassis user-assigned asset tag. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
ChassisType
Member of Chassis.v1_19_0.Chassis
Description | This property indicates the physical form factor type of this resource. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Rack |
An equipment rack, typically a 19-inch wide freestanding unit. |
Blade |
An enclosed or semi-enclosed, typically vertically-oriented, system chassis that must be plugged into a multi-system chassis to function normally. |
Enclosure |
A generic term for a chassis that does not fit any other description. |
StandAlone |
A single, free-standing system, commonly called a tower or desktop chassis. |
RackMount |
A single system chassis designed specifically for mounting in an equipment rack. |
Card |
A loose device or circuit board intended to be installed in a system or other enclosure. |
Cartridge |
A small self-contained system intended to be plugged into a multi-system chassis. |
Row |
A collection of equipment racks. |
Pod |
A collection of equipment racks in a large, likely transportable, container. |
Expansion |
A chassis that expands the capabilities or capacity of another chassis. |
Sidecar |
A chassis that mechanically connects with another chassis to expand its capabilities or capacity. |
Zone |
A logical division or portion of a physical chassis that contains multiple devices or systems that cannot be physically separated. |
Sled |
TBD |
Shelf |
An enclosed or semi-enclosed, typically horizontally-oriented, system chassis that must be plugged into a multi-system chassis to function normally. |
Other |
A chassis that does not fit any of these definitions. |
EnvironmentalClass
Member of Chassis.v1_19_0.Chassis
Description | The ASHRAE Environmental Class for this chassis. |
Type | string or null |
Read Only | False |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
A2 |
ASHRAE Environmental Class ‘A2’. |
A3 |
ASHRAE Environmental Class ‘A3’. |
A4 |
ASHRAE Environmental Class ‘A4’. |
Location
Location.PartLocation Location.PartLocation.LocationOrdinalValue Member of Chassis.v1_19_0.Chassis
Description | The number that represents the location of the part. If LocationType is slot and this unit is in slot 2, the LocationOrdinalValue is 2. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.10 |
Location.PartLocation.LocationType Member of Chassis.v1_19_0.Chassis
Description | The location types for PartLocation. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Slot |
The slot as the type of location. |
Bay |
The bay as the type of location. |
Connector |
The connector as the type of location. |
Socket |
The socket as the type of location. |
Embedded |
Embedded within a part. |
Location.PartLocation.Orientation Member of Chassis.v1_19_0.Chassis
Description | The orientation for the ordering of the part location ordinal value. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
FrontToBack |
The ordering for LocationOrdinalValue is front to back. |
BackToFront |
The ordering for the LocationOrdinalValue is back to front. |
TopToBottom |
The ordering for the LocationOrdinalValue is top to bottom. |
BottomToTop |
The ordering for LocationOrdinalValue is bottom to top. |
LeftToRight |
The ordering for the LocationOrdinalValue is left to right. |
RightToLeft |
The ordering for the LocationOrdinalValue is right to left. |
Location.PartLocation.Reference Member of Chassis.v1_19_0.Chassis
Description | The reference area for the location of the part. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Top |
The part is in the top of the unit. |
Bottom |
The part is in the bottom of the unit. |
Front |
The part is in the front of the unit. |
Rear |
The part is in the rear of the unit. |
Left |
The part is on the left side of of the unit. |
Right |
The part is on the right side of the unit. |
Middle |
The part is in the middle of the unit. |
Location.PartLocation.ServiceLabel Member of Chassis.v1_19_0.Chassis
Description | The label of the part location, such as a silk-screened name or a printed label. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Location.Placement Location.Placement.AdditionalInfo Member of Chassis.v1_19_0.Chassis
Description | Area designation or other additional info. |
Type | string or null |
Read Only | False |
Added | iLO6 1.10 |
Location.Placement.Rack Member of Chassis.v1_19_0.Chassis
Description | The name of a rack location within a row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.10 |
Location.Placement.RackOffset Member of Chassis.v1_19_0.Chassis
Description | The vertical location of the item, in terms of RackOffsetUnits. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.10 |
Location.Placement.RackOffsetUnits Member of Chassis.v1_19_0.Chassis
Description | The type of rack unit in use. |
Type | string or null |
Read Only | False |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OpenU |
A rack unit that is equal to 48 mm (1.89 in). |
EIA_310 |
A rack unit that is equal to 1.75 in (44.45 mm). |
Location.Placement.Row Member of Chassis.v1_19_0.Chassis
Description | The name of the row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.10 |
LocationIndicatorActive
Member of Chassis.v1_19_0.Chassis
Description | An indicator allowing an operator to physically locate this resource. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.10 |
Manufacturer
Member of Chassis.v1_19_0.Chassis
Description | The chassis manufacturer. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Model
Member of Chassis.v1_19_0.Chassis
Description | The chassis model number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
NetworkAdapters
The collection of network adapters contained within this chassis.
NetworkAdapters is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.BayNumber
Member of Chassis.v1_19_0.Chassis
Description | The bay number of the node or the blade. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.BaysConsumedHeight
Member of Chassis.v1_19_0.Chassis
Description | The number of enclosure bays this chassis consumes in height. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.BaysConsumedWidth
Member of Chassis.v1_19_0.Chassis
Description | The number of enclosure bays this chassis consumes in width. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ChassisPowerWatts
Member of Chassis.v1_19_0.Chassis
Description | The total power consumed by the chassis and nodes. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ElConfigOverride
Member of Chassis.v1_19_0.Chassis
Description | The value indicates if Thermal Configuration includes Edgeline specific options. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.EnclosureCPLD
Member of Chassis.v1_19_0.Chassis
Description | The CPLD version of the enclosure. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EnclosureDateTime
Member of Chassis.v1_19_0.Chassis
Description | The date and time in a Moonshot EL chassis (enclosure). |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | date-time |
Oem.Hpe.EnclosureIndicatorLED
Member of Chassis.v1_19_0.Chassis
Description | The enclosure indicator LED that is used to identify the enclosure. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The state of the Indicator LED cannot be determined. |
Lit |
The Indicator LED is on. |
Blinking |
The Indicator LED is blinking. |
Off |
The Indicator LED is off. |
Oem.Hpe.EnclosureModel
Member of Chassis.v1_19_0.Chassis
Description | Type of enclosure. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EnclosureUUID
Member of Chassis.v1_19_0.Chassis
Description | The UUID of the enclosure. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware
Oem.Hpe.Firmware.ChassisControllerVersion Oem.Hpe.Firmware.ChassisControllerVersion.Current Oem.Hpe.Firmware.ChassisControllerVersion.Current.VersionString Member of Chassis.v1_19_0.Chassis
Description | The firmware version of the chassis controller. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.CpuMezzProgrammableLogicDevice Oem.Hpe.Firmware.CpuMezzProgrammableLogicDevice.Current Oem.Hpe.Firmware.CpuMezzProgrammableLogicDevice.Current.VersionString Member of Chassis.v1_19_0.Chassis
Description | The firmware version of the CPLD. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Oem.Hpe.Firmware.PlatformDefinitionTable Oem.Hpe.Firmware.PlatformDefinitionTable.Current Oem.Hpe.Firmware.PlatformDefinitionTable.Current.VersionString Member of Chassis.v1_19_0.Chassis
Description | The version of the Intelligent Platform Abstraction Data. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.PowerManagementController Oem.Hpe.Firmware.PowerManagementController.Current Oem.Hpe.Firmware.PowerManagementController.Current.VersionString Member of Chassis.v1_19_0.Chassis
Description | The firmware version of the Power Monitor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.PowerManagementControllerBootloader Oem.Hpe.Firmware.PowerManagementControllerBootloader.Current Oem.Hpe.Firmware.PowerManagementControllerBootloader.Current.Family Member of Chassis.v1_19_0.Chassis
Description | The family type of the Power Monitor hardware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.PowerManagementControllerBootloader.Current.VersionString Member of Chassis.v1_19_0.Chassis
Description | The firmware version of the Power Monitor boot loader. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.SASProgrammableLogicDevice Oem.Hpe.Firmware.SASProgrammableLogicDevice.Current Oem.Hpe.Firmware.SASProgrammableLogicDevice.Current.VersionString Member of Chassis.v1_19_0.Chassis
Description | The firmware version of the SAS controller. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.SPSFirmwareVersionData Oem.Hpe.Firmware.SPSFirmwareVersionData.Current Oem.Hpe.Firmware.SPSFirmwareVersionData.Current.VersionString Member of Chassis.v1_19_0.Chassis
Description | The SPS FW Version number, aka ME FW Version, AAAA.BBBB.CCCC.DDDD.E |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.SecondarySystemProgrammableLogicDevice Oem.Hpe.Firmware.SecondarySystemProgrammableLogicDevice.Current Oem.Hpe.Firmware.SecondarySystemProgrammableLogicDevice.Current.VersionString Member of Chassis.v1_19_0.Chassis
Description | The firmware version of the CPLD. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.SystemProgrammableLogicDevice Oem.Hpe.Firmware.SystemProgrammableLogicDevice.Current Oem.Hpe.Firmware.SystemProgrammableLogicDevice.Current.VersionString Member of Chassis.v1_19_0.Chassis
Description | The firmware version of the CPLD. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.IPv4Address
Member of Chassis.v1_19_0.Chassis
Description | The IPv4 address of the chassis manager. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Images
Oem.Hpe.Images.Front Oem.Hpe.Images.Front.extref Member of Chassis.v1_19_0.Chassis
Description | The URI of an external resource. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Oem.Hpe.Images.Model Oem.Hpe.Images.Model.extref Member of Chassis.v1_19_0.Chassis
Description | The URI of an external resource. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Oem.Hpe.Location
Oem.Hpe.Location.GeographicLocation Oem.Hpe.Location.GeographicLocation.RackName Member of Chassis.v1_19_0.Chassis
Description | The name of the chassis enclosure. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Location.LocationInRack Oem.Hpe.Location.LocationInRack.RackLdsPartNumber Member of Chassis.v1_19_0.Chassis
Description | The chassis rack part number. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Location.LocationInRack.RackLdsProductDescription Member of Chassis.v1_19_0.Chassis
Description | The chassis rack product description. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Location.LocationInRack.RackUHeight Member of Chassis.v1_19_0.Chassis
Description | The chassis rack U height. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Location.LocationInRack.RackUUID Member of Chassis.v1_19_0.Chassis
Description | The chassis rack UUID. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Location.LocationInRack.TagVersion Member of Chassis.v1_19_0.Chassis
Description | The chassis rack tag version. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Location.LocationInRack.ULocation Member of Chassis.v1_19_0.Chassis
Description | The chassis rack U location. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Location.LocationInRack.UPosition Member of Chassis.v1_19_0.Chassis
Description | The chassis U position in the rack. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Location.LocationOfChassis Oem.Hpe.Location.LocationOfChassis.UUID Member of Chassis.v1_19_0.Chassis
Description | The chassis UUID provided by SMBIOS. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.MCTPEnabledOnServer
Member of Chassis.v1_19_0.Chassis
Description | Indicates if MCTP is enabled on the server or not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.NodePowerWatts
Member of Chassis.v1_19_0.Chassis
Description | The total power being consumed by this node. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.OnboardAdministrator
Oem.Hpe.OnboardAdministrator.IPv4Address Member of Chassis.v1_19_0.Chassis
Description | IPv4 address of the chassis. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.OnboardAdministrator.IPv6
Oem.Hpe.OnboardAdministrator.IPv6.DHCPv6Address (array)
Member of Chassis.v1_19_0.Chassis
DHCPv6Address
is an array containing elements of:
DHCPv6Address[{item}] Member of Chassis.v1_19_0.Chassis
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | ipv6 |
Oem.Hpe.OnboardAdministrator.IPv6.SLAACAddress (array)
Member of Chassis.v1_19_0.Chassis
SLAACAddress
is an array containing elements of:
SLAACAddress[{item}] Member of Chassis.v1_19_0.Chassis
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | ipv6 |
Oem.Hpe.OnboardAdministrator.IPv6.StaticAddress (array)
Member of Chassis.v1_19_0.Chassis
StaticAddress
is an array containing elements of:
StaticAddress[{item}] Member of Chassis.v1_19_0.Chassis
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | ipv6 |
Oem.Hpe.OnboardAdministrator.MacAddress Member of Chassis.v1_19_0.Chassis
Description | MAC address of the chassis. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PcieMini2SlotRiser
Member of Chassis.v1_19_0.Chassis
Description | PCIE mini 2 slot riser is a platform dependent value used to identify installation of this riser. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NotInstalled |
The PCIE mini 2 slot riser is not installed. The PCIE mini slot 3 and slot 4 do not exist in this Enclosure. |
InstalledWithOtherFRU |
A non recognized riser option is installed with a valid EEPROM FRU. Contact Customer Support to secure a replacement. |
InstalledWithBadFRU |
The PCIe mini 2 slot riser is installed with an invaild EEPROM FRU. Contact Customer Support to secure a replacement. |
Installed |
The PCIE mini 2 slot riser is installed. The PCIE mini slot 3 and slot 4 exist in this Enclosure. |
Oem.Hpe.PowerAlertMode
Oem.Hpe.PowerAlertMode.Activated Member of Chassis.v1_19_0.Chassis
Description | The power alert mode activation state. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PowerAlertMode.AlertPowerWatts Member of Chassis.v1_19_0.Chassis
Description | The power consumption of the system when operating in alert mode. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PowerAlertMode.SpikeWatts Member of Chassis.v1_19_0.Chassis
Description | Maximum additional power consumed when all CPUs are in Turbo Mode |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.RackName
Member of Chassis.v1_19_0.Chassis
Description | The name of the rack that contains the enclosure. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SmartStorageBattery (array)
Member of Chassis.v1_19_0.Chassis
SmartStorageBattery
is an array containing elements of:
SmartStorageBattery[{item}].BatteryWearLevelPercent Member of Chassis.v1_19_0.Chassis
Description | The battery wear level percentage. When this value reaches 100%, the battery is completely worn out and needs to be replaced. The value is null if battery wear level cannot be determined or is not supported. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
SmartStorageBattery[{item}].ChargeLevelPercent Member of Chassis.v1_19_0.Chassis
Description | State of charge of the battery. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
SmartStorageBattery[{item}].ErrorCode Member of Chassis.v1_19_0.Chassis
Description | Error code of the battery. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
GeneralFailure |
The battery has failed. |
HighInternalBatteryResistance |
The battery has failed due to high internal resistance. |
LowOpenCircuitVoltage |
The battery has failed due to a low voltage output. |
BatteryCellFailure |
The battery has failed. |
BatteryChargeTimeout |
The battery did not charge at the expected rate, indicating a faulty battery. |
OverTemperature |
The battery was disabled due to high ambient temperature, and will be re-enabled when the temperature is lowered. |
DischargeBelowMinimumVoltage |
The battery discharged below the minimum discharge voltage, and may be re-enabled upon recharging the battery. |
DischargeCurrentHigh |
The last backup failed due to exceeding the maximum discharge current. |
LoadCountExceeded |
The battery was disabled due to exceeding the maximum amount of devices supported, and will be re-enabled when the battery has been recharged or the additional devices are removed. |
BackupSucceeded |
The last backup succeeded within the expected time. |
OverCurrent |
The battery has been protected due to exceeding the output current capability. The battery should be re-enabled on the next reboot. |
PermanentFailure |
The battery has permanently failed. |
BackupTimeExceeded |
The last backup failed due to exceeding the battery discharge time limit. |
SmartStorageBattery[{item}].FailurePredicted Member of Chassis.v1_19_0.Chassis
Description | Is this battery currently predicting a failure in the near future. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
SmartStorageBattery[{item}].FirmwareVersion Member of Chassis.v1_19_0.Chassis
Description | Firmware version of the battery. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
SmartStorageBattery[{item}].Index Member of Chassis.v1_19_0.Chassis
Description | Index of the battery. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
SmartStorageBattery[{item}].MaximumCapWatts Member of Chassis.v1_19_0.Chassis
Description | Maximum capacity of the battery in watts. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
SmartStorageBattery[{item}].Model Member of Chassis.v1_19_0.Chassis
Description | Model of the battery. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
SmartStorageBattery[{item}].ProductName Member of Chassis.v1_19_0.Chassis
Description | Product name of the battery. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
SmartStorageBattery[{item}].RemainingChargeTimeSeconds Member of Chassis.v1_19_0.Chassis
Description | Remaining charging time of the battery in seconds. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
SmartStorageBattery[{item}].SerialNumber Member of Chassis.v1_19_0.Chassis
Description | Serial number of the battery. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
SmartStorageBattery[{item}].SparePartNumber Member of Chassis.v1_19_0.Chassis
Description | Spare part number of the battery. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
SmartStorageBattery[{item}].Status Member of Chassis.v1_19_0.Chassis See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.SystemMaintenanceSwitches
Oem.Hpe.SystemMaintenanceSwitches.Sw1 Member of Chassis.v1_19_0.Chassis
Description | Override iLO security. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
On |
iLO Security Override Enabled. |
Off |
No function (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw10 Member of Chassis.v1_19_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw11 Member of Chassis.v1_19_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw12 Member of Chassis.v1_19_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw2 Member of Chassis.v1_19_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw3 Member of Chassis.v1_19_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw4 Member of Chassis.v1_19_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw5 Member of Chassis.v1_19_0.Chassis
Description | BIOS/UEFI Password Disable. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
On |
Power On Password disabled. |
Off |
Power On Password enabled (Normal). |
Oem.Hpe.SystemMaintenanceSwitches.Sw6 Member of Chassis.v1_19_0.Chassis
Description | Reset Configuration. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
On |
|
Off |
Oem.Hpe.SystemMaintenanceSwitches.Sw7 Member of Chassis.v1_19_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Default). |
Oem.Hpe.SystemMaintenanceSwitches.Sw8 Member of Chassis.v1_19_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Default). |
Oem.Hpe.SystemMaintenanceSwitches.Sw9 Member of Chassis.v1_19_0.Chassis
Description | Reserved. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
On |
Switch is on. |
Off |
Switch is off (Default). |
Oem.Hpe.TelcoModeEnabled
Member of Chassis.v1_19_0.Chassis
Description | This property indicates if Telco mode is enabled on the server. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.10 |
Oem.Hpe.TrayID
Member of Chassis.v1_19_0.Chassis
Description | Tray ID is a platform dependent value used to identify what kind of server tray it is. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
PCIeDevices
The link to the collection of PCIe devices located in this chassis.
PCIeDevices is a link ("@odata.id": URI
) to another resource.
PCIeSlots
The link to the PCIe slot properties for this chassis.
PCIeSlots is a link ("@odata.id": URI
) to another resource.
PartNumber
Member of Chassis.v1_19_0.Chassis
Description | The chassis part number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PhysicalSecurity
PhysicalSecurity.IntrusionSensor Member of Chassis.v1_19_0.Chassis
Description | This indicates the known state of the physical security sensor, such as if it is hardware intrusion detected. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Normal |
No abnormal physical security conditions are detected at this time. |
HardwareIntrusion |
A door, lock, or other mechanism protecting the internal system hardware from being accessed is detected as being in an insecure state. |
TamperingDetected |
Physical tampering of the monitored entity is detected. |
PhysicalSecurity.IntrusionSensorReArm Member of Chassis.v1_19_0.Chassis
Description | This indicates how the Normal state to be restored. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Manual |
This sensor would be restored to the Normal state by a manual re-arm. |
Automatic |
This sensor would be restored to the Normal state automatically as no abnormal physical security conditions are detected. |
Power
A reference to the thermal metrics (power supplies, power policies, sensors) for this chassis.
Power is a link ("@odata.id": URI
) to another resource.
PowerState
Member of Chassis.v1_19_0.Chassis
Description | This is the current power state of the chassis. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Null |
On |
Off |
Unknown |
Reset |
SKU
Member of Chassis.v1_19_0.Chassis
Description | The chassis SKU. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SerialNumber
Member of Chassis.v1_19_0.Chassis
Description | The chassis serial number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of Chassis.v1_19_0.Chassis See the Redfish standard schema and specification for information on common Status object.
Thermal
A reference to the thermal metrics (fans, cooling, sensors) for this chassis.
Thermal is a link ("@odata.id": URI
) to another resource.
Actions
HpeServerChassis.DisableMCTPOnServer Member of Chassis.v1_19_0.Chassis There are no parameters for this action.
HpeServerChassis.FactoryResetMCTP Member of Chassis.v1_19_0.Chassis There are no parameters for this action.
HpeServerChassis.ModifyEnclosureChassisFru Member of Chassis.v1_19_0.Chassis The action to modify field of enclosure chassis FRU.
Parameters:
PartNumber (string)
Part Number of the enclosure chassis.
SerialNumber (string)
Serial Number of the enclosure chassis.
ChassisCollection.ChassisCollection
@odata.type: "#ChassisCollection.ChassisCollection"
A Collection of Chassis resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Chassis |
Members (array)
Member of ChassisCollection.ChassisCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of ChassisCollection.ChassisCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of ChassisCollection.ChassisCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
ComponentIntegrity.v1_2_0.ComponentIntegrity
@odata.type: "#ComponentIntegrity.v1_2_0.ComponentIntegrity"
The ComponentIntegrity resource provides critical and pertinent security information about a specific device, system, software element, or other managed entity.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/ComponentIntegrity/{item} |
GET POST |
ComponentIntegrityEnabled
Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Description | An indication of whether security protocols are enabled for the component. |
Type | boolean |
Read Only | False |
Added | iLO6 1.10 |
ComponentIntegrityType
Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Type | string |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
SPDM |
Security Protocol and Data Model (SPDM) protocol. |
TPM |
Trusted Platform Module (TPM). |
OEM |
OEM-specific. |
ComponentIntegrityTypeVersion
Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Description | The version of the security technology. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
SPDM
SPDM.IdentityAuthentication SPDM.IdentityAuthentication.ResponderAuthentication SPDM.IdentityAuthentication.ResponderAuthentication.VerificationStatus Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Description | The status of the verification of the identity of the component. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
Success |
Successful verification. |
Failed |
Unsuccessful verification. |
SPDM.MeasurementSet SPDM.MeasurementSet.MeasurementSpecification Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Type | string |
Read Only | True |
Added | iLO6 1.45 |
The following are the supported values:
Value | Description |
---|---|
DMTF |
DMTF. |
SPDM.MeasurementSet.Measurements (array)
Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Measurements
is an array containing elements of:
Measurements[{item}].LastUpdated Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Description | The date and time when information for the measurement was last updated. |
Type | string or null |
Read Only | True |
Added | iLO6 1.40 |
Format | date-time |
Measurements[{item}].Measurement Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Description | The measurement data. |
Type | string or null |
Read Only | True |
Added | iLO6 1.40 |
Measurements[{item}].MeasurementHashAlgorithm Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Description | The hash algorithm used to compute the measurement. |
Type | string or null |
Read Only | True |
Added | iLO6 1.40 |
Measurements[{item}].MeasurementIndex Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Description | The index of the measurement. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.45 |
Measurements[{item}].MeasurementType Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Type | string or null |
Read Only | True |
Added | iLO6 1.45 |
The following are the supported values:
Value | Description |
---|---|
ImmutableROM |
Immutable ROM. |
MutableFirmware |
Mutable firmware or any mutable code. |
HardwareConfiguration |
Hardware configuration, such as straps. |
FirmwareConfiguration |
Firmware configuration, such as configurable firmware policy. |
MutableFirmwareVersion |
Mutable firmware version. |
MutableFirmwareSecurityVersionNumber |
Mutable firmware security version number. |
MeasurementManifest |
Measurement Manifest. |
Measurements[{item}].SecurityVersionNumber Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Description | The security version number the measurement represents. |
Type | string or null |
Read Only | True |
Added | iLO6 1.45 |
Status
Member of ComponentIntegrity.v1_2_0.ComponentIntegrity See the Redfish standard schema and specification for information on common Status object.
TPM
TPM.ComponentCommunication
TPM.ComponentCommunication.Sessions (array)
Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Sessions
is an array containing elements of:
Sessions[{item}].SessionId Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Description | The identifier for an active session or communication channel between two components. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.40 |
Sessions[{item}].SessionType Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Type | string |
Read Only | True |
Added | iLO6 1.40 |
The following are the supported values:
Value | Description |
---|---|
Plain |
A plain text session without any protection. |
EncryptedAuthenticated |
An established session where both encryption and authentication are protecting the communication. |
AuthenticatedOnly |
An established session where only authentication is protecting the communication. |
TPM.MeasurementSet
TPM.MeasurementSet.Measurements (array)
Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Measurements
is an array containing elements of:
Measurements[{item}].LastUpdated Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Description | The date and time when information for the measurement was last updated. |
Type | string or null |
Read Only | True |
Added | iLO6 1.40 |
Format | date-time |
Measurements[{item}].Measurement Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Description | The measurement data. |
Type | string or null |
Read Only | True |
Added | iLO6 1.40 |
Measurements[{item}].MeasurementHashAlgorithm Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Description | The hash algorithm used to compute the measurement. |
Type | string or null |
Read Only | True |
Added | iLO6 1.40 |
Measurements[{item}].PCR Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Description | The Platform Configuration Register (PCR) bank of the measurement. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.40 |
TPM.NonceSizeBytesMaximum Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Description | The maximum number of bytes that can be specified in the Nonce parameter of the TPMGetSignedMeasurements action. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.40 |
TargetComponentURI
Member of ComponentIntegrity.v1_2_0.ComponentIntegrity
Description | The link to the the component whose integrity that this resource reports. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Actions
ComponentIntegrity.TPMGetSignedMeasurements Member of ComponentIntegrity.v1_2_0.ComponentIntegrity This action gets the TPM Signed Measurements.
Parameters:
Nonce (string)
A set of bytes as a hex-encoded string that is signed with the measurements. The value should be unique.
title (string)
Friendly action name
target (string)
Link to invoke action
PCRSelection (string)
An object that identify the PCRs to sign.
ComponentIntegrity.SPDMGetSignedMeasurements Member of ComponentIntegrity.v1_2_0.ComponentIntegrity This action gets the SPDM Signed Measurements.
Parameters:
Nonce (string)
A set of bytes as a hex-encoded string that is signed with the measurements. The value should be unique.
target (string)
Link to invoke action
title (string)
Friendly action name
SlotId (integer)
The slot identifier for the certificate containing the private key to generate the signature over the measurements.
MeasurementIndices (array)
An array of indices that identify the measurement blocks to sign.
ComponentIntegrityCollection.ComponentIntegrityCollection
@odata.type: "#ComponentIntegrityCollection.ComponentIntegrityCollection"
A Collection of ComponentIntegrity resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/ComponentIntegrity |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
ComponentIntegrity |
Members (array)
Member of ComponentIntegrityCollection.ComponentIntegrityCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of ComponentIntegrityCollection.ComponentIntegrityCollection
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Format | uri-reference |
Members@odata.count
Member of ComponentIntegrityCollection.ComponentIntegrityCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.10 |
ComputerSystem.v1_17_0.ComputerSystem
@odata.type: "#ComputerSystem.v1_17_0.ComputerSystem"
The ComputerSystem resource describes the compute node and its properties. A ComputerSystem represents a physical or virtual machine and the local resources, such as memory, CPU, and other devices that can be accessed from that machine.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item} |
GET POST PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
EthernetInterfaces |
Collection of EthernetInterface |
Oem/Hpe/Links/USBDevices |
Collection of HpeUSBDevice |
Links/Chassis[] |
Chassis |
Memory |
Collection of Memory |
Oem/Hpe/Links/USBPorts |
Collection of HpeUSBPort |
Oem/Hpe/Links/NetworkAdapters |
HpeBaseNetworkAdapterCollection |
NetworkInterfaces |
Collection of NetworkInterface |
Processors |
Collection of Processor |
SecureBoot |
SecureBoot |
Storage |
Collection of Storage |
Bios |
Bios |
LogServices |
Collection of LogService |
Oem/Hpe/Links/EthernetInterfaces |
Collection of EthernetInterface |
Oem/Hpe/Links/PCISlots |
Collection of HpeServerPCISlot |
Links/ManagedBy[] |
Manager |
Oem/Hpe/Links/PCIDevices |
Collection of HpeServerPciDevice |
AssetTag
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | A user-definable tag that is used to track this system for inventory or other client purposes. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Bios
The Bios URI.
Bios is a link ("@odata.id": URI
) to another resource.
BiosVersion
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The version of the system BIOS or primary system firmware. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Boot
Boot.BootOptions
A reference to the collection of the UEFI Boot Options associated with this Computer System.
BootOptions is a link ("@odata.id": URI
) to another resource.
Boot.BootOrder (array)
Member of ComputerSystem.v1_17_0.ComputerSystem
BootOrder
is an array containing elements of:
BootOrder[{item}] Member of ComputerSystem.v1_17_0.ComputerSystem
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Boot.BootSourceOverrideEnabled Member of ComputerSystem.v1_17_0.ComputerSystem
Description | BootSourceOverrideTarget must be specified before BootSourceOverrideEnabled can be used. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Disabled |
The system will boot normally. |
Once |
On its next boot cycle, the system will boot (one time) to the Boot Source Override Target. The value of BootSourceOverrideEnabled is then reset back to Disabled. |
Continuous |
The system will boot to the target specified in the BootSourceOverrideTarget until this property is set to Disabled. |
Boot.BootSourceOverrideMode Member of ComputerSystem.v1_17_0.ComputerSystem
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Legacy |
The system will boot in non-UEFI boot mode to the Boot Source Override Target. |
UEFI |
The system will boot in UEFI boot mode to the Boot Source Override Target. |
Boot.BootSourceOverrideTarget Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The current boot source to be used at next boot instead of the normal boot device, if BootSourceOverrideEnabled is true. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Boot.BootSourceOverrideTarget@Redfish.AllowableValues (array)
Member of ComputerSystem.v1_17_0.ComputerSystem
BootSourceOverrideTarget@Redfish.AllowableValues
is an array containing elements of:
BootSourceOverrideTarget@Redfish.AllowableValues[{item}] Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The current boot source to be used at next boot instead of the normal boot device, if BootSourceOverrideEnabled is not Disabled. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
None |
Boot from the normal boot device. |
Pxe |
Boot from the Pre-Boot EXecution (PXE) environment. |
Floppy |
Boot from the floppy disk drive. |
Cd |
Boot from the CD/DVD disc. |
Usb |
Boot from a USB device as specified by the system BIOS. |
Hdd |
Boot from a hard drive. |
BiosSetup |
Boot to the BIOS Setup Utility. |
Utilities |
Boot the manufacturer’s Utilities program(s). |
Diags |
Boot the manufacturer’s Diagnostics program. |
UefiShell |
Boot to the UEFI Shell. |
UefiTarget |
Boot to the UEFI Device specified in the UefiTargetBootSourceOverride property. |
SDCard |
Boot from an SD Card |
UefiHttp |
Boot from a UEFI HTTP network location |
Boot.UefiTargetBootSourceOverride Member of ComputerSystem.v1_17_0.ComputerSystem
Description | This property is the UEFI Device Path of the device to boot from when BootSourceOverrideTarget is UefiTarget. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Boot.UefiTargetBootSourceOverride@Redfish.AllowableValues (array)
Member of ComputerSystem.v1_17_0.ComputerSystem
UefiTargetBootSourceOverride@Redfish.AllowableValues
is an array containing elements of:
UefiTargetBootSourceOverride@Redfish.AllowableValues[{item}] Member of ComputerSystem.v1_17_0.ComputerSystem
Description | An array of structured boot strings. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
BootProgress
BootProgress.LastState Member of ComputerSystem.v1_17_0.ComputerSystem
Description | SmartNIC device operating system status |
Type | string or null |
Read Only | False |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
OSBootStarted |
The operating system has started booting. |
OSRunning |
The operating system is running. |
OEM |
The operating system state is reported in the OemLastState property. |
BootProgress.OemLastState Member of ComputerSystem.v1_17_0.ComputerSystem
Description | SmartNIC device operating system oem status |
Type | string or null |
Read Only | False |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
OSServicesReady |
The operating system services are ready. |
OSServicesOffline |
The operating system services are offline. |
OSHalting |
The operating system has started halting. |
OSHalted |
The operating system has performed a shutdown. |
EthernetInterfaces
A reference to the collection of Ethernet interfaces associated with this system.
EthernetInterfaces is a link ("@odata.id": URI
) to another resource.
HostName
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The DNS Host Name, without any domain information |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
HostingRole
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The enumerations of HostingRoles specify different features that the hosting ComputerSystem supports. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ApplicationServer |
The system hosts functionality that supports general purpose applications. |
StorageServer |
The system hosts functionality that supports the system acting as a storage server. |
Switch |
The system hosts functionality that supports the system acting as a switch. |
Appliance |
The system hosts functionality that supports the system acting as an appliance. |
BareMetalServer |
The system hosts functionality that supports the system acting as a bare metal server. |
VirtualMachineServer |
The system hosts functionality that supports the system acting as a virtual machine server. |
ContainerServer |
The system hosts functionality that supports the system acting as a container server. |
LocationIndicatorActive
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | An indicator allowing an operator to physically locate this resource. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.10 |
LogServices
The LogService collection URI for this resource.
LogServices is a link ("@odata.id": URI
) to another resource.
Manufacturer
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The manufacturer or OEM of this system. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Memory
The central memory in the system.
Memory is a link ("@odata.id": URI
) to another resource.
MemoryDomains
A reference to the collection of Memory Domains associated with this system.
MemoryDomains is a link ("@odata.id": URI
) to another resource.
MemorySummary
MemorySummary.Status Member of ComputerSystem.v1_17_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
MemorySummary.TotalSystemMemoryGiB Member of ComputerSystem.v1_17_0.ComputerSystem
Description | This is the total amount of memory in the system measured in GiB. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemorySummary.TotalSystemPersistentMemoryGiB Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The total configured, system-accessible persistent memory, measured in GiB. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Model
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The model information that the manufacturer uses to refer to this system. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
NetworkInterfaces
The collection of network interfaces partitioned to this system.
NetworkInterfaces is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.AggregateHealthStatus
Oem.Hpe.AggregateHealthStatus.AgentlessManagementService Member of ComputerSystem.v1_17_0.ComputerSystem
Description | This indicates if the Agentless Management Service is available or not. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Unavailable |
The Agentless Management Service is unavailable. |
Ready |
The Agentless Management Service is Ready. |
Oem.Hpe.AggregateHealthStatus.AggregateServerHealth Member of ComputerSystem.v1_17_0.ComputerSystem
Description | This represents the overall health state |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
Oem.Hpe.AggregateHealthStatus.BiosOrHardwareHealth Oem.Hpe.AggregateHealthStatus.BiosOrHardwareHealth.Status Member of ComputerSystem.v1_17_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.FanRedundancy Member of ComputerSystem.v1_17_0.ComputerSystem
Description | This indicates if the Fan is redundant or not. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Redundant |
The fans are Redundant. |
NonRedundant |
The fans are not Redundant. |
FailedRedundant |
The Redundant fan has failed. |
Unknown |
The Redundant state is unknown. |
Oem.Hpe.AggregateHealthStatus.Fans Oem.Hpe.AggregateHealthStatus.Fans.Status Member of ComputerSystem.v1_17_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.LiquidCooling Oem.Hpe.AggregateHealthStatus.LiquidCooling.Status Member of ComputerSystem.v1_17_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.LiquidCoolingRedundancy Member of ComputerSystem.v1_17_0.ComputerSystem
Description | This indicates if the LiquidCooling Units are redundant or not. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Redundant |
The Liquid Cooling modules are Redundant. |
NonRedundant |
The Liquid Cooling modules are not Redundant. |
FailedRedundant |
The Redundant fan has failed. |
Unknown |
The Redundant state is unknown. |
Oem.Hpe.AggregateHealthStatus.Memory Oem.Hpe.AggregateHealthStatus.Memory.Status Member of ComputerSystem.v1_17_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.Network Oem.Hpe.AggregateHealthStatus.Network.Status Member of ComputerSystem.v1_17_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.PowerSupplies Oem.Hpe.AggregateHealthStatus.PowerSupplies.PowerSuppliesMismatch Member of ComputerSystem.v1_17_0.ComputerSystem
Description | This indicates if the there is a mismatch in the power supplies. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.AggregateHealthStatus.PowerSupplies.Status Member of ComputerSystem.v1_17_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.PowerSupplyRedundancy Member of ComputerSystem.v1_17_0.ComputerSystem
Description | This indicates if the Power Supply is redundant or not. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Redundant |
The power supplies are Redundant. |
NonRedundant |
The power supplies are not Redundant. |
FailedRedundant |
The Redundant power supply has failed. |
Unknown |
The Redundant state is unknown. |
Oem.Hpe.AggregateHealthStatus.Processors Oem.Hpe.AggregateHealthStatus.Processors.Status Member of ComputerSystem.v1_17_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.SmartStorageBattery Oem.Hpe.AggregateHealthStatus.SmartStorageBattery.Status Member of ComputerSystem.v1_17_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.Storage Oem.Hpe.AggregateHealthStatus.Storage.Status Member of ComputerSystem.v1_17_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AggregateHealthStatus.Temperatures Oem.Hpe.AggregateHealthStatus.Temperatures.Status Member of ComputerSystem.v1_17_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.AvailableSystemCapabilities (array)
Member of ComputerSystem.v1_17_0.ComputerSystem
AvailableSystemCapabilities
is an array containing elements of:
AvailableSystemCapabilities[{item}] Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Indicates SmartNIC DPU supports OS-triggered DPC |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value |
---|
OSTriggeredDPC |
Oem.Hpe.Bios
Oem.Hpe.Bios.Backup Oem.Hpe.Bios.Backup.BuildNumber Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The build number of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Backup.BuildNumberString Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The string version of the build number of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Backup.Date Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The build date of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Backup.DebugBuild Member of ComputerSystem.v1_17_0.ComputerSystem
Description | True if the firmware is a debug build; False if it is not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Backup.Family Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The family of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Backup.MajorVersion Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The major version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Backup.MinorVersion Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The minor version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Backup.Time Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The build time of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Backup.VersionString Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The version string of the firmware. This value might be null if VersionString is unavailable. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Bootblock Oem.Hpe.Bios.Bootblock.BuildNumber Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The build number of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Bootblock.BuildNumberString Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The string version of the build number of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Bootblock.Date Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The build date of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Bootblock.DebugBuild Member of ComputerSystem.v1_17_0.ComputerSystem
Description | True if the firmware is a debug build; False if it is not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Bootblock.Family Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The family of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Bootblock.MajorVersion Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The major version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Bootblock.MinorVersion Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The minor version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Bootblock.Time Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The build time of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Bootblock.VersionString Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The version string of the firmware. This value might be null if VersionString is unavailable. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Current Oem.Hpe.Bios.Current.BuildNumber Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The build number of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Current.BuildNumberString Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The string version of the build number of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Current.Date Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The build date of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Current.DebugBuild Member of ComputerSystem.v1_17_0.ComputerSystem
Description | True if the firmware is a debug build; False if it is not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Current.Family Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The family of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Current.MajorVersion Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The major version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Current.MinorVersion Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The minor version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Current.Time Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The build time of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.Current.VersionString Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The version string of the firmware. This value might be null if VersionString is unavailable. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Bios.UefiClass Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The UEFI BIOS Class value defined in the UEFI specification. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Null |
1 |
2 |
3 |
Oem.Hpe.BootProgress
Oem.Hpe.BootProgress.OemResetReason Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The Smart NIC Device Operating system OEM reset reason . |
Type | string or null |
Read Only | False |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
Unknown |
unknown reason, cold start |
OSNormal |
a normal reset by ESXio |
BMCNormal |
reset by BMC |
OSCrash |
a reset after a crash by ESXio |
HWWatchdog |
a reset due to hardware watchdog |
Thermal |
a reset due to thermal shutdown |
Oem.Hpe.BootProgress.ResetReason Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The Smart NIC Device Operating system reset reason . |
Type | string or null |
Read Only | False |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
OEM |
oem value , SmartNIC DPU |
Unknown |
unknown reason, cold start |
OSNormal |
a normal reset by ESXio |
BMCNormal |
reset by BMC |
OSCrash |
a reset after a crash by ESXio |
HWWatchdog |
a reset due to hardware watchdog |
Thermal |
a reset due to thermal shutdown |
Oem.Hpe.CriticalTempRemainOff
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Indicates whether server should remain off after thermal shutdown is triggered. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.CurrentPowerOnTimeSeconds
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Displays the amount of time(in seconds) that has passed since the server was last powered on. The data is reset on iLO reset. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DeviceDiscoveryComplete
Oem.Hpe.DeviceDiscoveryComplete.AMSDeviceDiscovery Member of ComputerSystem.v1_17_0.ComputerSystem
Description | This property indicates the current AMS Device Discovery Status. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Busy |
The server has AMS loaded and iLO is discovering devices that require AMS to be loaded |
Complete |
The server has AMS loaded and iLO is finished discovering devices that require AMS to be loaded |
NoAMS |
The server does not have AMS loaded for device discovery. |
Initial |
Default state after iLO has booted. |
Oem.Hpe.DeviceDiscoveryComplete.DeviceDiscovery Member of ComputerSystem.v1_17_0.ComputerSystem
Description | This property indicates the current device discovery status of devices that are not Smart Array or AMS related. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Busy |
iLO is discovering devices. |
vAuxDeviceDiscoveryComplete |
The server is off and iLO is finished discovering devices. |
vMainDeviceDiscoveryComplete |
The server is on and iLO is finished discovering devices. |
DataIncomplete |
iLO response took longer than expected while discovering devices. |
Initial |
Default state after iLO has booted. |
Oem.Hpe.DeviceDiscoveryComplete.SmartArrayDiscovery Member of ComputerSystem.v1_17_0.ComputerSystem
Description | This property indicates the current Smart Array Storage Device Discovery Status |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Busy |
iLO is discovering Smart Array devices. If the server is shutdown before discovery is complete, this reflects an incomplete data set. |
PendingSoftwareRAID |
Pending discovery of Dynamic Smart Array. |
Complete |
iLO is finished discovering Smart Array storage. |
Initial |
Default state for Smart Array |
Cached |
Data is cached, server is offline or data not yet available. |
Oem.Hpe.ElapsedEraseTimeInMinutes
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Reports the time elapsed since the erase started |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EnabledSystemCapabilities (array)
Member of ComputerSystem.v1_17_0.ComputerSystem
EnabledSystemCapabilities
is an array containing elements of:
EnabledSystemCapabilities[{item}] Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Indicates SmartNIC DPU supports OS-triggered DPC |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value |
---|
OSTriggeredDPC |
Oem.Hpe.EndOfPostDelaySeconds
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Supported on UEFI based systems only. The number of seconds to delay before finalizing POST with the Mode action (e.g. delay before shutdown). If > 255 seconds is requested, the value is rounded up to the nearest minute. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.EstimatedEraseTimeInMinutes
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Reports the guestimate time (in minutes) for the overall erase process |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.HostOS
Oem.Hpe.HostOS.OsName Member of ComputerSystem.v1_17_0.ComputerSystem
Description | from cpqHoName if AMS is running |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.HostOS.OsSysDescription Member of ComputerSystem.v1_17_0.ComputerSystem
Description | from cpqHosysDesc if AMS is running |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.HostOS.OsType Member of ComputerSystem.v1_17_0.ComputerSystem
Description | from cpqHoOsType if AMS is running. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.HostOS.OsVersion Member of ComputerSystem.v1_17_0.ComputerSystem
Description | from cpqHoVersion if AMS is running |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.IndicatorLED
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The state of the indicator LED. |
Type | string or null |
Read Only | False |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Lit |
The Indicator LED is lit. |
Blinking |
The indicator LED is blinking. |
Off |
The Indicator LED is off. |
Oem.Hpe.IntegrationConfig
Oem.Hpe.IntegrationConfig.OsReadyTimeout Member of ComputerSystem.v1_17_0.ComputerSystem
Type | integer |
Read Only | False |
Added | iLO6 1.10 |
Oem.Hpe.IntelligentProvisioningAlwaysOn
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Always on Intelligent Provisioning is available. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.IntelligentProvisioningIndex
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Index in the Firmware Version Table for Intelligent Provisioning. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.IntelligentProvisioningLocation
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Location string of Intelligent Provisioning in Firmware Version Table. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.IntelligentProvisioningVersion
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Intelligent Provisioning Version. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.IsColdBooting
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Indicates if the system is cold booting. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.OperatingSystem
Oem.Hpe.OperatingSystem.Kernel Oem.Hpe.OperatingSystem.Kernel.Version Member of ComputerSystem.v1_17_0.ComputerSystem
Description | SmartNIC device operating system kernel version |
Type | string or null |
Read Only | False |
Added | iLO6 1.10 |
Oem.Hpe.PCAPartNumber
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The PCA part number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PCASerialNumber
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The PCA serial number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PostDiscoveryCompleteTimeStamp
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Displays the last known POST Discovery Complete time |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Oem.Hpe.PostDiscoveryMode
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The manner in which the system will operate during the discovery section of POST. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Auto |
BIOS will automatically use ForceFastBoot if the system hardware has not changed from last time of FullDiscovery or ForceFullDiscovery if the system hardware has changed. |
ForceFullDiscovery |
Server makes a full discovery of all devices. |
ForceFastBoot |
Server uses the existing cached discovery data. |
Oem.Hpe.PostMode
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The manner in which the system will operate during and at completion of POST. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Normal |
Normal operations. |
PostToShutdown |
Server boots until Discovery Completes, then shuts down. |
PostToReboot |
Server boots until Discovery Completes, then reboots. |
PostToWait |
Server boots until Discovery Completes, then indefintely waits. |
Oem.Hpe.PostState
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The current state of system POST. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
iLO was unable to determine the current server state. |
Reset |
The server is currently in reset. |
PowerOff |
The server power is off. |
InPost |
The server is booting and has not reached discovery complete. |
InPostDiscoveryStart |
The server has started to discover devices. |
InPostDiscoveryComplete |
The server has reached discovery complete and is now waiting for the installed OS to be booted. Discovery complete is the point at which it has been deemed safe to read and write the BIOS configuration information. |
FinishedPost |
The server has booted the installed OS. |
Oem.Hpe.PowerAllocationLimit
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The total amount of power allocated to the system. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PowerAutoOn
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Auto Power-On mode defines what occurs when the AC power is applied to the system. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
RemainOff |
PowerOn |
Restore |
Oem.Hpe.PowerOnDelay
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The PowerAutoOn policy delay that can also be found in the HpBios::PowerOnDelay object. Will be null if PowerAutoOn is set to RemainOff. Blades only support Minimum and RandomUpTo120Sec. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Null |
Minimum |
15Sec |
30Sec |
45Sec |
60Sec |
RandomUpTo120Sec |
Oem.Hpe.PowerOnMinutes
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The number of lifetime minutes that the server has been powered on. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PowerRegulatorMode
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Power Regulator mode. Switching to and from OS Control mode requires a server reboot to take effect. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
OSControl |
Dynamic |
Max |
Min |
Unknown |
Oem.Hpe.PowerRegulatorModesSupported (array)
Member of ComputerSystem.v1_17_0.ComputerSystem
PowerRegulatorModesSupported
is an array containing elements of:
PowerRegulatorModesSupported[{item}] Member of ComputerSystem.v1_17_0.ComputerSystem
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SMBIOS
Oem.Hpe.SMBIOS.extref Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The URI of an external resource. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Oem.Hpe.ServerFQDN
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The IP address or FQDN of the server. Host software like AMS is required to obtain this value from the OS. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.ServerIntelligentDiagnosticsModeEnabled
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Indicates the current state of server Intelligent Diagnostics mode. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ServerSafeModeEnabled
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Indicates the current state of server Safe Mode. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ServerSignature
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The CRC32 of: All Device Signatures combined together, Server Slot Location in Enclosure, Enclosure UUID, and Manager Domain IP Address |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ServerSignatureStatus
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The current state of Server Signature. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Initial |
The server signature calculation has not run yet. |
Busy |
The server signature calculation is being run. |
Invalid |
The server signature is invalid. Re-compute action necessary. |
Complete |
The server signature calculation is complete and valid. |
Oem.Hpe.SmartStorageConfig (array)
Member of ComputerSystem.v1_17_0.ComputerSystem
SmartStorageConfig
is an array containing elements of:
SmartStorageConfig[{item}].@odata.id Member of ComputerSystem.v1_17_0.ComputerSystem
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Oem.Hpe.SystemROMAndiLOEraseComponentStatus
Oem.Hpe.SystemROMAndiLOEraseComponentStatus.BIOSSettingsEraseStatus Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Oem.Hpe.SystemROMAndiLOEraseComponentStatus.iLOSettingsEraseStatus Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Oem.Hpe.SystemROMAndiLOEraseStatus
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Oem.Hpe.SystemUsage
Oem.Hpe.SystemUsage.AvgCPU0Freq Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Current CPU0 average frequency in MHz. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SystemUsage.AvgCPU1Freq Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Current CPU1 average frequency in MHz. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SystemUsage.AvgCPU2Freq Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Current CPU2 average frequency in MHz. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SystemUsage.AvgCPU3Freq Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Current CPU3 average frequency in MHz. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SystemUsage.CPU0Power Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Current power consumed by the system CPU0 in Watts. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SystemUsage.CPU1Power Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Current power consumed by the system CPU1 in Watts. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SystemUsage.CPU2Power Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Current power consumed by the system CPU2 in Watts. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SystemUsage.CPU3Power Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Current power consumed by the system CPU3 in Watts. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SystemUsage.CPUICUtil Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Current System CPU Interconnect utilization in percentage |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SystemUsage.CPUUtil Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Current System CPU utilization in percentage |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SystemUsage.IOBusUtil Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Current System I/O bus utilization in percentage |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SystemUsage.JitterCount Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Current processor Jitter Count. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SystemUsage.MemoryBusUtil Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Current System memory bus utilization in percentage |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.UserDataEraseComponentStatus
Oem.Hpe.UserDataEraseComponentStatus.NVDIMMEraseStatus Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Oem.Hpe.UserDataEraseComponentStatus.NVMeDrivesEraseStatus Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Oem.Hpe.UserDataEraseComponentStatus.SATADrivesEraseStatus Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Oem.Hpe.UserDataEraseComponentStatus.TPMEraseStatus Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Oem.Hpe.UserDataEraseStatus
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Indicates the erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates SecureSystem Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
Oem.Hpe.VirtualProfile
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The current state of the systems virtual profile. This profile is the one that, when the server is rebooted, will set the Virtual properties. Intent is to use this state to determine whether the server needs to be rebooted so these values are set. Additional informaiton about the profile will be considered later. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Active |
Busy |
Inactive |
Unknown |
Oem.Hpe.VirtualUUID
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Used in conjunction with the UUID (Logical) value. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PartNumber
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The manufacturer’s system part number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerState
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | This is the current power state of the system |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Null |
On |
Off |
Unknown |
Reset |
PoweringOn |
PoweringOff |
ProcessorSummary
ProcessorSummary.Count Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The number of processors in the system. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorSummary.Model Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The processor model for the primary or majority of processors in this system. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorSummary.Status Member of ComputerSystem.v1_17_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Processors
The central processors in the system.
Processors is a link ("@odata.id": URI
) to another resource.
SKU
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | SKU for this system. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SecureBoot
A reference to the UEFI SecureBoot resource associated with this system.
SecureBoot is a link ("@odata.id": URI
) to another resource.
SerialNumber
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The system serial number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of ComputerSystem.v1_17_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
Storage
A reference to the collection of storage devices associated with this system.
Storage is a link ("@odata.id": URI
) to another resource.
SystemType
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The type of computer system that this resource represents. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Physical |
A computer system |
Virtual |
A virtual machine instance running on this system |
OS |
An operating system instance |
PhysicallyPartitioned |
A hardware-based partition of a computer system |
VirtuallyPartitioned |
A virtual or software-based partition of a computer system |
DPU |
SmartNIC DPU System |
TrustedModules (array)
Member of ComputerSystem.v1_17_0.ComputerSystem
TrustedModules
is an array containing elements of:
TrustedModules[{item}].FirmwareVersion Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The firmware version of this Trusted Module |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
TrustedModules[{item}].InterfaceType Member of ComputerSystem.v1_17_0.ComputerSystem
Description | This property indicates the interface type of the Trusted Module. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
TM1_0 |
Trusted Module ™ 1.0 |
TPM1_2 |
Trusted Platform Module (TPM) 1.2 |
TPM2_0 |
Trusted Platform Module (TPM) 2.0 |
TrustedModules[{item}].Oem.Hpe.VendorName Member of ComputerSystem.v1_17_0.ComputerSystem
Description | Trusted module vendor name. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
None |
STMicro |
Intel |
Nationz |
Unknown |
TrustedModules[{item}].Status Member of ComputerSystem.v1_17_0.ComputerSystem See the Redfish standard schema and specification for information on common Status object.
UUID
Member of ComputerSystem.v1_17_0.ComputerSystem
Description | The universal unique identifier for this system. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Actions
ComputerSystem.Reset Member of ComputerSystem.v1_17_0.ComputerSystem This action resets the system.
Parameters:
ResetType (string)
The type of reset.
Value | Description |
---|---|
GracefulRestart | Shut down gracefully and restart the system. |
GracefulShutdown | Shut down gracefully and power off. |
PowerCycle | Power cycle the unit. |
On | Turn on the unit. |
ForceOff | Turn off the unit immediately (non-graceful shutdown). |
PushPowerButton | Simulate the pressing of the physical power button on this unit. |
ForceOn | Turn on the unit immediately. |
ForceRestart | Shut down immediately and non-gracefully and restart the system. |
Nmi | Generate a diagnostic interrupt, which is usually an NMI on x86 systems, to stop normal operations, complete diagnostic actions, and, typically, halt the system. |
target (string)
Link to invoke action
title (string)
Friendly action name
HpeComputerSystemExt.SystemReset Member of ComputerSystem.v1_17_0.ComputerSystem
Parameters:
ResetType (string)
ResetType identifies the type of Action to be performed.
Value | Description |
---|---|
ColdBoot | |
AuxCycle |
HpeComputerSystemExt.ServerIntelligentDiagnosticsMode Member of ComputerSystem.v1_17_0.ComputerSystem There are no parameters for this action.
HpeComputerSystemExt.ServerSafeMode Member of ComputerSystem.v1_17_0.ComputerSystem There are no parameters for this action.
HpeComputerSystemExt.RestoreSystemDefaults Member of ComputerSystem.v1_17_0.ComputerSystem There are no parameters for this action.
HpeComputerSystemExt.PowerButton Member of ComputerSystem.v1_17_0.ComputerSystem
Parameters:
PushType (string)
PushType identifies the type of Action to be performed.
Value | Description |
---|---|
Press | |
PressAndHold |
HpeComputerSystemExt.SecureSystemErase Member of ComputerSystem.v1_17_0.ComputerSystem
Parameters:
UserDataErase (boolean)
Action to perform erasing all the user data on the system including TPMs, persistent memory devices, storage controller configurations, RAID settings, as well as the hard drives attached to the system. USB and other removable media will be excluded.
SystemROMAndiLOErase (boolean)
Action to perform resetting the system BIOS settings and iLO to manufacturing defaults. It also erases the user data in the NAND like Active Health System(AHS), Repository.
ComputerSystem.SetSimpleUpdateStatus Member of ComputerSystem.v1_17_0.ComputerSystem
Parameters:
Message (string)
Message to be displayed
TaskState (string)
TaskState identifies the type of Action to be performed.
Value | Description |
---|---|
New | |
Starting | |
Running | |
Suspended | |
Interrupted | |
Pending | |
Stopping | |
Completed | |
Killed | |
Exception | |
Service |
PercentComplete (integer)
Percentage of task complete
TaskStatus (string)
Current status of the ongoing task
Value | Description |
---|---|
Ok | |
Warning | |
Critical |
HpeComputerSystemExt.ServerSigRecompute Member of ComputerSystem.v1_17_0.ComputerSystem There are no parameters for this action.
HpeComputerSystemExt.RestoreManufacturingDefaults Member of ComputerSystem.v1_17_0.ComputerSystem There are no parameters for this action.
ComputerSystemCollection.ComputerSystemCollection
@odata.type: "#ComputerSystemCollection.ComputerSystemCollection"
A Collection of ComputerSystem resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
ComputerSystem |
Members (array)
Member of ComputerSystemCollection.ComputerSystemCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of ComputerSystemCollection.ComputerSystemCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of ComputerSystemCollection.ComputerSystemCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Drive.v1_14_0.Drive
@odata.type: "#Drive.v1_14_0.Drive"
The Drive resource describes a single physical disk drive for a system, including links to associated Volumes.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/storage/{item}/drives/{item} |
GET POST PATCH |
BlockSizeBytes
Member of Drive.v1_14_0.Drive
Description | The size of the smallest addressible unit (Block) of this drive in bytes |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
CapableSpeedGbs
Member of Drive.v1_14_0.Drive
Description | The speed which this drive can communicate to a storage controller in ideal conditions in Gigabits per second |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
CapacityBytes
Member of Drive.v1_14_0.Drive
Description | The size in bytes of this Drive |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
EncryptionAbility
Member of Drive.v1_14_0.Drive
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
None |
The drive is not capable of self encryption |
SelfEncryptingDrive |
The drive is capable of self encryption per the Trusted Computing Group’s Self Encrypting Drive Standard |
Other |
The drive is capable of self encryption through some other means |
EncryptionStatus
Member of Drive.v1_14_0.Drive
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Unencrypted |
|
Unlocked |
The drive is currently encrypted but the data is accessible to the user unencrypted. |
Locked |
The drive is currently encrypted and the data is not accessible to the user, however the system has the ability to unlock the drive automatically. |
Foreign |
The drive is currently encrypted, the data is not accessible to the user, and the system requires user intervention to expose the data. |
FailurePredicted
Member of Drive.v1_14_0.Drive
Description | Is this drive currently predicting a failure in the near future |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
HotspareType
Member of Drive.v1_14_0.Drive
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
None |
The drive is not currently a hotspare |
Global |
The drive is currently serving as a hotspare for all other drives in the storage system. |
Chassis |
The drive is currently serving as a hotspare for all other drives in the chassis. |
Dedicated |
The drive is currently serving as a hotspare for a user defined set of drives. |
Identifiers (array)
Member of Drive.v1_14_0.Drive
Identifiers
is an array containing elements of:
Identifiers[{item}].DurableName Member of Drive.v1_14_0.Drive
Description | The world-wide, persistent name of the resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Identifiers[{item}].DurableNameFormat Member of Drive.v1_14_0.Drive
Description | The format of the durable name property. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NAA |
The Name Address Authority (NAA) format. |
iQN |
The iSCSI Qualified Name (iQN). |
FC_WWN |
The Fibre Channel (FC) World Wide Name (WWN). |
UUID |
The Universally Unique Identifier (UUID). |
EUI |
The IEEE-defined 64-bit Extended Unique Identifier (EUI). |
NQN |
The NVMe Qualified Name (NQN). |
NGUID |
The Namespace Globally Unique Identifier (NGUID). |
Location (array)
Member of Drive.v1_14_0.Drive
Location
is an array containing elements of:
Location[{item}].Info Member of Drive.v1_14_0.Drive
Description | This indicates the location of the resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Location[{item}].InfoFormat Member of Drive.v1_14_0.Drive
Description | This represents the format of the Info property. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Box:Bay |
The Info is the box and bay number of the Drive. |
BayNumber |
The Info is the bay number of the Drive. |
Slot |
The Info is the PCIe slot of the Drive (eg: NVMe drives). |
LocationIndicatorActive
Member of Drive.v1_14_0.Drive
Description | An indicator allowing an operator to physically locate this resource. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.10 |
Manufacturer
Member of Drive.v1_14_0.Drive
Description | This is the manufacturer of this drive. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MediaType
Member of Drive.v1_14_0.Drive
Description | The type of media contained in this drive. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
HDD |
The drive media type is traditional magnetic platters |
SSD |
The drive media type is solid state or flash memory |
Model
Member of Drive.v1_14_0.Drive
Description | This is the model number for the drive. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
NegotiatedSpeedGbs
Member of Drive.v1_14_0.Drive
Description | The speed which this drive is currently communicating to the storage controller in Gigabits per second |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.CriticalWarning
Member of Drive.v1_14_0.Drive
Description | Failure information reported by the drive. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
AvailableSpareSpace |
Available spare space has fallen below the threshold. |
TemperatureTheshold |
A temperature is above an over temperature threshold or below an under temperature threshold. |
ReliabilityError |
The NVM subsystem reliability has been degraded due to significant media related errors or any internal error that degrades NVM subsystem reliability. |
ReadOnlyMode |
The media has been placed in read only mode. |
VolatileBackupFailure |
The volatile memory backup device has failed. This field is only valid if the controller has a volatile memory backup solution |
Oem.Hpe.CurrentTemperatureCelsius
Member of Drive.v1_14_0.Drive
Description | The current temperature of the drive |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DriveStatus
Oem.Hpe.DriveStatus.Health Member of Drive.v1_14_0.Drive
Description | This represents the health state of this resource in the absence of its dependent resources. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
Oem.Hpe.DriveStatus.HealthRollup Member of Drive.v1_14_0.Drive
Description | This represents the overall health state from the view of this resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
Oem.Hpe.DriveStatus.State Member of Drive.v1_14_0.Drive
Description | This indicates the known state of the resource, such as if it is enabled. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Enabled |
This function or resource has been enabled. |
Disabled |
This function or resource has been disabled. |
StandbyOffline |
This function or resource is enabled, but awaiting an external action to activate it. |
StandbySpare |
This function or resource is part of a redundancy set and is awaiting a failover or other external action to activate it. |
InTest |
This function or resource is undergoing testing. |
Starting |
This function or resource is starting. |
Absent |
This function or resource is not present or not detected. |
UnavailableOffline |
This function or resource is present but cannot be used. |
Deferring |
The element will not process any commands but will queue new requests. |
Quiesced |
The element is enabled but only processes a restricted set of commands. |
Updating |
The element is updating and may be unavailable or degraded. |
Oem.Hpe.HealthUpdated
Member of Drive.v1_14_0.Drive
Description | Describes how drive health related data (FailurePredicted, PredictedMediaLifeLeftPercent, Status, DriveStatus, CriticalWarning, WearStatus) are updated. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Boot |
The health related properties are updated when the system boot and are not updated at runtime. |
Dynamic |
The health related properties are updated periodically at runtime. |
Oem.Hpe.NVMeId
Member of Drive.v1_14_0.Drive
Description | NVMe Identifier: ModelName, SerialNumber, PCI-Vendor-ID. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PowerOnHours
Member of Drive.v1_14_0.Drive
Description | The number of lifetime hours that the drive has been powered on. The value is null if the disk power on hours cannot be determined or is not supported. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.TemperatureStatus
Oem.Hpe.TemperatureStatus.Health Member of Drive.v1_14_0.Drive
Description | This represents the health state of this resource in the absence of its dependent resources. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
Oem.Hpe.TemperatureStatus.HealthRollup Member of Drive.v1_14_0.Drive
Description | This represents the overall health state from the view of this resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
Oem.Hpe.TemperatureStatus.State Member of Drive.v1_14_0.Drive
Description | This indicates the known state of the resource, such as if it is enabled. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Enabled |
This function or resource has been enabled. |
Disabled |
This function or resource has been disabled. |
StandbyOffline |
This function or resource is enabled, but awaiting an external action to activate it. |
StandbySpare |
This function or resource is part of a redundancy set and is awaiting a failover or other external action to activate it. |
InTest |
This function or resource is undergoing testing. |
Starting |
This function or resource is starting. |
Absent |
This function or resource is not present or not detected. |
UnavailableOffline |
This function or resource is present but cannot be used. |
Deferring |
The element will not process any commands but will queue new requests. |
Quiesced |
The element is enabled but only processes a restricted set of commands. |
Updating |
The element is updating and may be unavailable or degraded. |
Oem.Hpe.WearStatus
Member of Drive.v1_14_0.Drive
Description | The wear status of the drive, an estimation of remaining life span. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
OK |
The SSD is not in any imminent danger of wear out. |
FiftySixDayThreshold |
Indicates that based upon the current workload, the solid state disk will reach the maximum usage limit for writes (wear out) within fifty-six days. You should modify your write workload or begin preparing to replace your SSD drive |
FivePercentThreshold |
Indicates that the solid state disk has passed the five percent threshold and is at or below five percent of reaching the maximum usage limit for writes (wear out). You should begin to prepare to replace your SSD drive. |
TwoPercentThreshold |
Indicates that the solid state disk has passed the two percent threshold and is at or below two percent of reaching the maximum usage limit for writes (wear out). You should begin to prepare to replace your SSD drive. |
SSDWearOut |
Indicates that a solid state drive is approaching the maximum usage limit for writes (wear out) and should be replaced as soon as possible. |
Unknown |
The SSD wear status cannot be determined. |
Operations
Operations.AssociatedTask Operations.AssociatedTask.EndTime Member of Drive.v1_14_0.Drive
Description | The date-time stamp that the task was last completed. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Operations.AssociatedTask.Messages (array)
Member of Drive.v1_14_0.Drive
Messages
is an array containing elements of:
Messages[{item}].Message Member of Drive.v1_14_0.Drive
Description | This is the human readable message, if provided. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Messages[{item}].MessageArgs (array)
Member of Drive.v1_14_0.Drive
MessageArgs
is an array containing elements of:
MessageArgs[{item}] Member of Drive.v1_14_0.Drive
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Messages[{item}].MessageId Member of Drive.v1_14_0.Drive
Description | This is the key for this message which can be used to look up the message in a message registry. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Messages[{item}].RelatedProperties (array)
Member of Drive.v1_14_0.Drive
RelatedProperties
is an array containing elements of:
RelatedProperties[{item}] Member of Drive.v1_14_0.Drive
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Messages[{item}].Resolution Member of Drive.v1_14_0.Drive
Description | Used to provide suggestions on how to resolve the situation that caused the error. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Messages[{item}].Severity Member of Drive.v1_14_0.Drive
Description | This is the severity of the event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
Operations.AssociatedTask.Payload
Operations.AssociatedTask.Payload.HttpHeaders (array)
Member of Drive.v1_14_0.Drive
HttpHeaders
is an array containing elements of:
HttpHeaders[{item}] Member of Drive.v1_14_0.Drive
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Operations.AssociatedTask.Payload.HttpOperation Member of Drive.v1_14_0.Drive
Description | The HTTP operation to perform to execute this Task. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Operations.AssociatedTask.Payload.JsonBody Member of Drive.v1_14_0.Drive
Description | This property contains the JSON payload to use in the execution of this Task. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Operations.AssociatedTask.Payload.TargetUri Member of Drive.v1_14_0.Drive
Description | The URI of the target for this task. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Operations.AssociatedTask.StartTime Member of Drive.v1_14_0.Drive
Description | The date-time stamp that the task was last started. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Operations.AssociatedTask.TaskMonitor Member of Drive.v1_14_0.Drive
Description | The URI of the Task Monitor for this task. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Operations.AssociatedTask.TaskState Member of Drive.v1_14_0.Drive
Description | The state of the task. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
New |
A new task. |
Starting |
Task is starting. |
Running |
Task is running normally. |
Suspended |
Task has been suspended. |
Interrupted |
Task has been interrupted. |
Pending |
Task is pending and has not started. |
Stopping |
Task is in the process of stopping. |
Completed |
Task has completed. |
Killed |
Task was terminated. |
Exception |
Task has stopped due to an exception condition. |
Service |
Task is running as a service. |
Operations.AssociatedTask.TaskStatus Member of Drive.v1_14_0.Drive
Description | This is the completion status of the task. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
OK |
Normal. |
Warning |
A condition exists that requires attention. |
Critical |
A critical condition exists that requires immediate attention. |
Operations.OperationName Member of Drive.v1_14_0.Drive
Description | The name of the operation. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Operations.PercentageComplete Member of Drive.v1_14_0.Drive
Description | The percentage of the operation that has been completed. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PartNumber
Member of Drive.v1_14_0.Drive
Description | The part number for this drive. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PhysicalLocation
PhysicalLocation.PartLocation PhysicalLocation.PartLocation.LocationOrdinalValue Member of Drive.v1_14_0.Drive
Description | The number that represents the location of the part. If LocationType is slot and this unit is in slot 2, the LocationOrdinalValue is 2. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PhysicalLocation.PartLocation.LocationType Member of Drive.v1_14_0.Drive
Description | The location types for PartLocation. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Slot |
The slot as the type of location. |
Bay |
The bay as the type of location. |
Connector |
The connector as the type of location. |
Socket |
The socket as the type of location. |
Embedded |
Embedded within a part. |
PhysicalLocation.PartLocation.Orientation Member of Drive.v1_14_0.Drive
Description | The orientation for the ordering of the part location ordinal value. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
FrontToBack |
The ordering for LocationOrdinalValue is front to back. |
BackToFront |
The ordering for the LocationOrdinalValue is back to front. |
TopToBottom |
The ordering for the LocationOrdinalValue is top to bottom. |
BottomToTop |
The ordering for LocationOrdinalValue is bottom to top. |
LeftToRight |
The ordering for the LocationOrdinalValue is left to right. |
RightToLeft |
The ordering for the LocationOrdinalValue is right to left. |
PhysicalLocation.PartLocation.Reference Member of Drive.v1_14_0.Drive
Description | The reference area for the location of the part. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Top |
The part is in the top of the unit. |
Bottom |
The part is in the bottom of the unit. |
Front |
The part is in the front of the unit. |
Rear |
The part is in the rear of the unit. |
Left |
The part is on the left side of of the unit. |
Right |
The part is on the right side of the unit. |
Middle |
The part is in the middle of the unit. |
PhysicalLocation.PartLocation.ServiceLabel Member of Drive.v1_14_0.Drive
Description | The label of the part location, such as a silk-screened name or a printed label. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PhysicalLocation.Placement PhysicalLocation.Placement.AdditionalInfo Member of Drive.v1_14_0.Drive
Description | Area designation or other additional info. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
PhysicalLocation.Placement.Rack Member of Drive.v1_14_0.Drive
Description | The name of a rack location within a row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
PhysicalLocation.Placement.RackOffset Member of Drive.v1_14_0.Drive
Description | The vertical location of the item, in terms of RackOffsetUnits. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
PhysicalLocation.Placement.RackOffsetUnits Member of Drive.v1_14_0.Drive
Description | The type of rack unit in use. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OpenU |
A rack unit that is equal to 48 mm (1.89 in). |
EIA_310 |
A rack unit that is equal to 1.75 in (44.45 mm). |
PhysicalLocation.Placement.Row Member of Drive.v1_14_0.Drive
Description | The name of the row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
PredictedMediaLifeLeftPercent
Member of Drive.v1_14_0.Drive
Description | The percentage of reads and writes that are predicted to still be available for the media |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Protocol
Member of Drive.v1_14_0.Drive
Description | The protocol this drive is using to communicate to the storage controller |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
SAS |
Serial Attached SCSI. |
NVMe |
Non-Volatile Memory Express |
SATA |
Serial AT Attachment |
USB |
Universal Serial Bus |
Revision
Member of Drive.v1_14_0.Drive
Description | The revision of this Drive |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
RotationSpeedRPM
Member of Drive.v1_14_0.Drive
Description | The rotation speed of this Drive in Revolutions per Minute (RPM) |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
SerialNumber
Member of Drive.v1_14_0.Drive
Description | Serial Number of the drive. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of Drive.v1_14_0.Drive See the Redfish standard schema and specification for information on common Status object.
StatusIndicator
Member of Drive.v1_14_0.Drive
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
OK |
The drive is OK. |
Fail |
The drive has failed. |
Rebuild |
The drive is being rebuilt. |
PredictiveFailureAnalysis |
The drive is still working but predicted to fail soon. |
Hotspare |
The drive is marked to be automatically rebuilt and used as a replacement for a failed drive. |
InACriticalArray |
The array that this drive is a part of is degraded. |
InAFailedArray |
The array that this drive is a part of is failed. |
WriteCacheEnabled
Member of Drive.v1_14_0.Drive
Description | An indication of whether the drive write cache is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Actions
Drive.Reset Member of Drive.v1_14_0.Drive
Parameters:
target (string)
Link to invoke action
ResetValue (string)
Reset Drive
Value | Description |
---|---|
ForceOff | Turn off the unit immediately (non-graceful shutdown). |
ForceOn | Turn on the unit immediately. |
PowerCycle | Power cycle the unit. |
EthernetInterface.v1_4_1.EthernetInterface
@odata.type: "#EthernetInterface.v1_4_1.EthernetInterface"
The EthernetInterface resource describes a single, logical ethernet interface or network interface controller (NIC).
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/ethernetinterfaces/{item} |
GET PATCH |
/redfish/v1/systems/{item}/ethernetinterfaces/{item} |
GET POST PATCH |
AutoNeg
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates if the speed and duplex are automatically negotiated and configured on this interface. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
DHCPv4
DHCPv4.DHCPEnabled Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether DHCPv4 is enabled on this interface. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
DHCPv4.UseDNSServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to use DHCPv4-supplied DNS servers. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
DHCPv4.UseDomainName Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to use a DHCPv4-supplied domain name. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
DHCPv4.UseGateway Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to use a DHCPv4-supplied gateway. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
DHCPv4.UseNTPServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to use DHCPv4-supplied NTP servers. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
DHCPv4.UseStaticRoutes Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to use DHCPv4-supplied static routes. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
DHCPv6
DHCPv6.OperatingMode Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines the DHCPv6 operating mode for this interface. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Stateful |
DHCPv6 stateful mode. |
Stateless |
DHCPv6 stateless mode. |
Disabled |
DHCPv6 is disabled. |
DHCPv6.UseDNSServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | When enabled, DNS server addresses supplied through DHCPv6 stateless mode will be used. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
DHCPv6.UseDomainName Member of EthernetInterface.v1_4_1.EthernetInterface
Description | When enabled, the domain name supplied through DHCPv6 stateless mode will be used. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
DHCPv6.UseNTPServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | When enabled, NTP server addresses supplied through DHCPv6 stateless mode will be used. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
DHCPv6.UseRapidCommit Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to use DHCPv6 rapid commit mode for stateful mode address assignments. Do not enable in networks where more than one DHCPv6 server is configured to provide address assignments. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
FQDN
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the complete, fully qualified domain name obtained by DNS for this interface. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
FullDuplex
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates if the interface is in Full Duplex mode or not. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
HostName
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The DNS Host Name, without any domain information. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
IPv4Addresses (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
IPv4Addresses
is an array containing elements of:
IPv4Addresses[{item}].Address Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv4 Address. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
IPv4Addresses[{item}].AddressOrigin Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates how the address was determined. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Static |
A static address as configured by the user. |
DHCP |
Address is provided by a DHCPv4 service. |
BOOTP |
Address is provided by a BOOTP service. |
IPv4LinkLocal |
Address is valid only for this network segment (link). |
IPv4Addresses[{item}].Gateway Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv4 gateway for this address. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
IPv4Addresses[{item}].SubnetMask Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv4 Subnet mask. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
IPv4StaticAddresses (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
IPv4StaticAddresses
is an array containing elements of:
IPv4StaticAddresses[{item}].Address Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv4 Address. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
IPv4StaticAddresses[{item}].AddressOrigin Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates how the address was determined. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Static |
A static address as configured by the user. |
DHCP |
Address is provided by a DHCPv4 service. |
BOOTP |
Address is provided by a BOOTP service. |
IPv4LinkLocal |
Address is valid only for this network segment (link). |
IPv4StaticAddresses[{item}].Gateway Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv4 gateway for this address. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
IPv4StaticAddresses[{item}].SubnetMask Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv4 Subnet mask. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
IPv6AddressPolicyTable (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
IPv6AddressPolicyTable
is an array containing elements of:
IPv6AddressPolicyTable[{item}].Label Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The IPv6 Label (as defined in RFC 6724 section 2.1). |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
IPv6AddressPolicyTable[{item}].Precedence Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The IPv6 Precedence (as defined in RFC 6724 section 2.1. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
IPv6AddressPolicyTable[{item}].Prefix Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The IPv6 Address Prefix (as defined in RFC 6724 section 2.1). |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
IPv6Addresses (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
IPv6Addresses
is an array containing elements of:
IPv6Addresses[{item}].Address Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv6 Address. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
IPv6Addresses[{item}].AddressOrigin Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates how the address was determined. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Static |
A static address as configured by the user. |
DHCPv6 |
Address is provided by a DHCPv6 service. |
LinkLocal |
Address is valid only for this network segment (link). |
SLAAC |
Address is provided by a Stateless Address AutoConfiguration (SLAAC) service. |
IPv6Addresses[{item}].AddressState Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The current state of this address as defined in RFC 4862. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Preferred |
This address is currently within both it’s valid and preferred lifetimes as defined in RFC 4862. |
Deprecated |
This address is currently within it’s valid lifetime, but is now outside of it’s preferred lifetime as defined in RFC 4862. |
Tentative |
This address is currently undergoing Duplicate Address Detection testing as defined in RFC 4862 section 5.4. |
Failed |
This address has failed Duplicate Address Detection testing as defined in RFC 4862 section 5.4 and is not currently in use. |
IPv6Addresses[{item}].PrefixLength Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv6 Address Prefix Length. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
IPv6DefaultGateway
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the IPv6 default gateway address that is currently in use on this interface. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
IPv6StaticAddresses (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
IPv6StaticAddresses
is an array containing elements of:
IPv6StaticAddresses[{item}].Address Member of EthernetInterface.v1_4_1.EthernetInterface
Description | A valid IPv6 address. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
IPv6StaticAddresses[{item}].PrefixLength Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The Prefix Length of this IPv6 address. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
IPv6StaticDefaultGateways (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
IPv6StaticDefaultGateways
is an array containing elements of:
IPv6StaticDefaultGateways[{item}].Address Member of EthernetInterface.v1_4_1.EthernetInterface
Description | A valid IPv6 address. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
IPv6StaticDefaultGateways[{item}].PrefixLength Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The Prefix Length of this IPv6 address. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
InterfaceEnabled
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates whether this interface is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
LinkStatus
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The link status of this interface (port). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
LinkUp |
The link is available for communication on this interface. |
NoLink |
There is no link or connection detected on this interface. |
LinkDown |
There is no link on this interface, but the interface is connected. |
MACAddress
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the currently configured MAC address of the (logical port) interface. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
MTUSize
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the currently configured Maximum Transmission Unit (MTU) in bytes on this interface. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
MaxIPv6StaticAddresses
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates the maximum number of Static IPv6 addresses that can be configured on this interface. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
NameServers (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
NameServers
is an array containing elements of:
NameServers[{item}] Member of EthernetInterface.v1_4_1.EthernetInterface
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ConfigurationSettings
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The state of the currently displayed configuration settings. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Current |
All configuration settings for this NIC are currently in use. |
SomePendingReset |
One or more configuration settings on this NIC are not yet in use. They require a reset of this management processor in order to take effect. |
Oem.Hpe.DHCPv4
Oem.Hpe.DHCPv4.ClientId Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The client ID to override the default used in iLO. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DHCPv4.ClientIdType Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The type of client id in use or to be selected. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Custom |
Allows user to enter any value. |
Default |
Use the default iLO5 value - MAC Address + Instance number. |
Hostname |
Use the hostname. |
MacAddress |
Use the default iLO4 value - MAC Address. |
Oem.Hpe.DHCPv4.Enabled Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv4.DHCPEnabled, and will be removed in a future release. Determines whether DHCPv4 is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DHCPv4.UseDNSServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv4.UseDNSServers, and will be removed in a future release. Determines whether to use DHCPv4-supplied DNS servers. Can only be enabled when DHCPv4 is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DHCPv4.UseDomainName Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv4.UseDomainName, and will be removed in a future release. Determines whether to use a DHCPv4-supplied domain name. Can only be enabled when DHCPv4 is also enabled; otherwis,e this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DHCPv4.UseGateway Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv4.UseGateway, and will be removed in a future release. Determines whether to use a DHCPv4-supplied gateway. Can only be enabled when DHCPv4 is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DHCPv4.UseNTPServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv4.UseNTPServers, and will be removed in a future release. Determines whether to use DHCPv4-supplied NTP servers. Can only be enabled when DHCPv4 is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DHCPv4.UseStaticRoutes Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv4.UseStaticRoutes, and will be removed in a future release. Determines whether to use DHCPv4-supplied static routes. Can only be enabled when DHCPv4 is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DHCPv4.UseWINSServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to use DHCPv4-supplied WINS servers. Can only be enabled when DHCPv4 is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DHCPv6
Oem.Hpe.DHCPv6.StatefulModeEnabled Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv6Configuration.OperatingMode, and will be removed in a future release.Determines whether DHCPv6 Stateful mode is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DHCPv6.StatelessModeEnabled Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv6Configuration.OperatingMode, and will be removed in a future release. Determines whether DHCPv6 Stateless mode is enabled. Always enabled by default whenever DHCPv6 Stateful mode is also enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DHCPv6.UseDNSServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv6Configuration.UseDNSServers, and will be removed in a future release. Determines whether to use DHCPv6-supplied DNS servers. Can only be enabled when DHCPv6 Stateless mode is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DHCPv6.UseDomainName Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv6Configuration.UseDomainName, and will be removed in a future release. Determines whether to use a DHCPv6-supplied domain name. Can only be enabled when DHCPv6 Stateless mode is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DHCPv6.UseNTPServers Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv6Configuration.UseNTPServers, and will be removed in a future release. Determines whether to use DHCPv6-supplied NTP servers. Can only be enabled when DHCPv6 Stateless mode is also enabled; otherwise, this property will be set to false and will be read-only. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DHCPv6.UseRapidCommit Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property DHCPv6Configuration.UseRapidCommit, and will be removed in a future release. Determines whether to use DHCPv6 rapid commit mode. Can only be enabled when DHCPv6 Stateful mode is also enabled; otherwise, this property will be set to false and will be read-only. Do not enable in networks where more than one DHCPv6 server is configured to provide address assignments. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DomainName
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Domain name of the network to which this management processor belongs. This property can only be modified when the management processor is not configured to use a DHCP supplied domain name; otherwise this property is read-only indicating the value is provided by DHCP. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.HostName
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property HostName, and will be removed in a future release. The management processor host name. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | hostname |
Oem.Hpe.IPv4
Oem.Hpe.IPv4.DDNSRegistration Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether DDNS registration is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.IPv4.DNSServers (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
DNSServers
is an array containing elements of:
DNSServers[{item}] Member of EthernetInterface.v1_4_1.EthernetInterface
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | ipv4 |
Oem.Hpe.IPv4.StaticRoutes (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
StaticRoutes
is an array containing elements of:
StaticRoutes[{item}].Destination Member of EthernetInterface.v1_4_1.EthernetInterface
Description | An IPv4 static route destination. Only writeable when use of DHCPv4-supplied static routes is disabled; otherwise this property is read-only indicating the value is provided by DHCPv4. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | ipv4 |
StaticRoutes[{item}].Gateway Member of EthernetInterface.v1_4_1.EthernetInterface
Description | An IPv4 static route gateway. Only writeable when use of DHCPv4-supplied static routes is disabled; otherwise this property is read-only indicating the value is provided by DHCPv4. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | ipv4 |
StaticRoutes[{item}].SubnetMask Member of EthernetInterface.v1_4_1.EthernetInterface
Description | An IPv4 static route subnet mask. Only writeable when use of DHCPv4-supplied static routes is disabled; otherwise this property is read-only indicating the value is provided by DHCPv4. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | ipv4 |
Oem.Hpe.IPv4.WINSRegistration Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether WINS registration is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.IPv4.WINSServers (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
WINSServers
is an array containing elements of:
WINSServers[{item}] Member of EthernetInterface.v1_4_1.EthernetInterface
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | ipv4 |
Oem.Hpe.IPv6
Oem.Hpe.IPv6.DDNSRegistration Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether IPv6 DDNS registration is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.IPv6.DNSServers (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
DNSServers
is an array containing elements of:
DNSServers[{item}] Member of EthernetInterface.v1_4_1.EthernetInterface
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | ipv6 |
Oem.Hpe.IPv6.SLAACEnabled Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property StatelessAddressAutoConfig.IPv6AutoConfigEnabled, and will be removed in a future release. Determines whether StateLess Address Auto-Configuration is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.IPv6.StaticDefaultGateway Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property IPv6StaticDefaultGateways[].Address, and will be removed in a future release. The IPv6 static default gateway entry. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | ipv6 |
Oem.Hpe.IPv6.StaticRoutes (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
StaticRoutes
is an array containing elements of:
StaticRoutes[{item}].Destination Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The IPv6 static route destination address. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | ipv6 |
StaticRoutes[{item}].Gateway Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The IPv6 static route gateway. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | ipv6 |
StaticRoutes[{item}].PrefixLength Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The prefix length of the IPv6 static route destination address. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
StaticRoutes[{item}].Status Member of EthernetInterface.v1_4_1.EthernetInterface See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.InterfaceType
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Describes the network interface type. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Dedicated |
Shared |
HostInterface |
Oem.Hpe.NICEnabled
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Deprecated, replaced by DMTF standard property InterfaceEnabled, and will be removed in a future release. Determines whether this NIC is enabled or disabled. Enabling one NIC will disable the others. If no NIC is enabled, this management processor is not accessible over the network. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.NICSupportsIPv6
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Indicates whether or not this NIC can support the IPv6 protocol. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PingGatewayOnStartup
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Determines whether to ping the IPv4 gateway on startup. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.SharedNetworkPortOptions
Oem.Hpe.SharedNetworkPortOptions.NIC Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Selects the system NIC that is to be shared with this management processor. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
OCP1 |
The OCP1 NIC is configured to be shared. |
OCP2 |
The OCP2 NIC is configured to be shared. |
EmbeddedNIC |
The EmbeddedNIC is configured to be shared. |
Oem.Hpe.SharedNetworkPortOptions.Port Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The network adapter port number that is used for sharing. This feature is only applicable on systems and network adapters that support it. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.SupportsEmbeddedNIC
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Indicates whether this system supports LOM. Only applies to Shared Network Port. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SupportsOCP1
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Indicates whether this system supports OCP1. Only applies to Shared Network Port. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SupportsOCP2
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Indicates whether this system supports OCP2. Only applies to Shared Network Port. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
PermanentMACAddress
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the permanent MAC address assigned to this interface (port). |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
SpeedMbps
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This is the current speed in Mbps of this interface. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
StatelessAddressAutoConfig
StatelessAddressAutoConfig.IPv4AutoConfigEnabled Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Indicates whether IPv4 SLAAC is enabled for this interface. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
StatelessAddressAutoConfig.IPv6AutoConfigEnabled Member of EthernetInterface.v1_4_1.EthernetInterface
Description | Indicates whether IPv6 SLAAC is enabled for this interface. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
StaticNameServers (array)
Member of EthernetInterface.v1_4_1.EthernetInterface
StaticNameServers
is an array containing elements of:
StaticNameServers[{item}] Member of EthernetInterface.v1_4_1.EthernetInterface
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of EthernetInterface.v1_4_1.EthernetInterface See the Redfish standard schema and specification for information on common Status object.
UefiDevicePath
Member of EthernetInterface.v1_4_1.EthernetInterface
Description | The UEFI device path for this interface. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
VLAN
VLAN.VLANEnable Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates if this VLAN is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
VLAN.VLANId Member of EthernetInterface.v1_4_1.EthernetInterface
Description | This indicates the VLAN identifier for this VLAN. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
VLANs
This is a reference to a collection of VLANs and is only used if the interface supports more than one VLANs.
VLANs is a link ("@odata.id": URI
) to another resource.
EthernetInterfaceCollection.EthernetInterfaceCollection
@odata.type: "#EthernetInterfaceCollection.EthernetInterfaceCollection"
A Collection of EthernetInterface resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/ethernetinterfaces |
GET |
/redfish/v1/systems/{item}/ethernetinterfaces |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
EthernetInterface |
Members (array)
Member of EthernetInterfaceCollection.EthernetInterfaceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of EthernetInterfaceCollection.EthernetInterfaceCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of EthernetInterfaceCollection.EthernetInterfaceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
EventDestination.v1_12_0.EventDestination
@odata.type: "#EventDestination.v1_12_0.EventDestination"
The EventDestination resource describes the target of an event subscription, including the types of events subscribed and context to provide to the target in the Event payload.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/eventservice/subscriptions/{item} |
GET PATCH DELETE |
Context
Member of EventDestination.v1_12_0.EventDestination
Description | A client-supplied string that is stored with the listener destination subscription. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Destination
Member of EventDestination.v1_12_0.EventDestination
Description | The URI of the destination listener service. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | uri-reference |
HttpHeaders (array)
Member of EventDestination.v1_12_0.EventDestination
HttpHeaders
is an array containing elements of:
HttpHeaders[{item}]
Oem.Hpe.DeliveryRetryAttempts
Member of EventDestination.v1_12_0.EventDestination
Description | This is the number of attempts an event posting is retried before the subscription is terminated. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DeliveryRetryIntervalInSeconds
Member of EventDestination.v1_12_0.EventDestination
Description | This represents the number of seconds between retry attempts for sending any given Event |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.MutualAuthenticationEnabled
Member of EventDestination.v1_12_0.EventDestination
Description | This represents if the subscriber and iLO need to perform mutual authentication when an event is sent. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.RequestedMaxEventsToQueue
Member of EventDestination.v1_12_0.EventDestination
Description | This represents the number of events the service should queue. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.RetireOldEventInMinutes
Member of EventDestination.v1_12_0.EventDestination
Description | This represents the number of minutes until an event is expired. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Protocol
Member of EventDestination.v1_12_0.EventDestination
Description | The protocol type of the event connection. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Redfish |
RegistryPrefixes (array)
Member of EventDestination.v1_12_0.EventDestination
RegistryPrefixes
is an array containing elements of:
RegistryPrefixes[{item}] Member of EventDestination.v1_12_0.EventDestination
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SubscriptionType
Member of EventDestination.v1_12_0.EventDestination
Description | The subscription type for events. |
Type | string or null |
Read Only | True |
Added | iLO6 1.20 |
The following are the supported values:
Value |
---|
RedfishEvent |
EventDestinationCollection.EventDestinationCollection
@odata.type: "#EventDestinationCollection.EventDestinationCollection"
A Collection of EventDestination resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/eventservice/subscriptions |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
EventDestination |
Members (array)
Member of EventDestinationCollection.EventDestinationCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of EventDestinationCollection.EventDestinationCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of EventDestinationCollection.EventDestinationCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
EventService.v1_7_2.EventService
@odata.type: "#EventService.v1_7_2.EventService"
The EventService resource describes the Event Service. It represents the properties for the service itself and has links to the actual list of subscriptions.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/eventservice |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Subscriptions |
Collection of EventDestination |
Oem/Hpe/CACertificates |
Collection of HpeCertificate |
DeliveryRetryAttempts
Member of EventService.v1_7_2.EventService
Description | This is the number of attempts an event posting is retried before the subscription is terminated. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
DeliveryRetryIntervalSeconds
Member of EventService.v1_7_2.EventService
Description | This represents the number of seconds between retry attempts for sending any given Event |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
EventTypesForSubscription (array)
Member of EventService.v1_7_2.EventService
EventTypesForSubscription
is an array containing elements of:
EventTypesForSubscription[{item}] Member of EventService.v1_7_2.EventService
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
StatusChange |
The status of this resource has changed |
ResourceUpdated |
The value of this resource has been updated |
ResourceAdded |
A resource has been added |
ResourceRemoved |
A resource has been removed |
Alert |
A condition exists which requires attention |
Oem.Hpe.CACertificates
The value of this property shall be a reference to a Collection of HpeCertificate resources.
CACertificates is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.RequestedMaxEventsToQueueDefault
Member of EventService.v1_7_2.EventService
Description | This represents the default number of events the service should queue. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.RetireOldEventInMinutesDefault
Member of EventService.v1_7_2.EventService
Description | This represents the default number of minutes until an event is expired. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.TTLCountDefault
Member of EventService.v1_7_2.EventService
Description | The default number of TTLUnits until this listener destination subscription expires. It may be renewed prior to expire to reset the Time to Live counter. The value 999999 is reserved to mean a perpetual subscription. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.TTLUnitsDefault
Member of EventService.v1_7_2.EventService
Description | The default time unit used to measure the subscription time of this listener destination. This is the units for TTLCount and is used to express the subscription lifetime of the listener destination. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
seconds |
Time to Live (TTL) in Seconds |
minutes |
Time to Live (TTL) in Minutes |
days |
Time to Live (TTL) in Days |
RegistryPrefixes (array)
Member of EventService.v1_7_2.EventService
RegistryPrefixes
is an array containing elements of:
RegistryPrefixes[{item}] Member of EventService.v1_7_2.EventService
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ServiceEnabled
Member of EventService.v1_7_2.EventService
Description | This indicates whether this service is enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of EventService.v1_7_2.EventService See the Redfish standard schema and specification for information on common Status object.
Subscriptions
This is a reference to a collection of ListenerDestination resources.
Subscriptions is a link ("@odata.id": URI
) to another resource.
Actions
EventService.SubmitTestEvent Member of EventService.v1_7_2.EventService
Parameters:
EventId (string)
Severity (string)
Value | Description |
---|---|
OK | |
Warning | |
Critical |
EventType (string)
Value | Description |
---|---|
StatusChange | |
ResourceUpdated | |
ResourceAdded | |
ResourceRemoved | |
Alert |
OriginOfCondition (string)
EventTimestamp (string)
MessageId (string)
Message (string)
MessageArgs (array)
HpeEventService.ImportCACertificate Member of EventService.v1_7_2.EventService Imports a Trusted CA Certificate
Parameters:
Certificate (string)
Contains PEM formatted X509 certificate or PKCS7 certificate chain (Base64 encoded).
HostInterface.v1_1_1.HostInterface
@odata.type: "#HostInterface.v1_1_1.HostInterface"
The HostInterface resource describes a Redfish Host Interface, which is a method of accessing the Redfish API from the host computer system.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/hostinterfaces/{item} |
GET PATCH |
AuthenticationModes (array)
Member of HostInterface.v1_1_1.HostInterface
AuthenticationModes
is an array containing elements of:
AuthenticationModes[{item}].AuthenticationMode Member of HostInterface.v1_1_1.HostInterface
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
AuthNone |
Requests without any sort of authentication are allowed. |
BasicAuth |
Requests using HTTP Basic Authentication are allowed. |
RedfishSessionAuth |
Requests using Redfish Session Authentication are allowed. |
OemAuth |
Requests using OEM authentication mechanisms are allowed. |
ExternallyAccessible
Member of HostInterface.v1_1_1.HostInterface
Description | This indicates whether this interface is accessible by external entities. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
FirmwareAuthEnabled
Member of HostInterface.v1_1_1.HostInterface
Description | This indicates whether this firmware authentication is enabled for this interface. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
FirmwareAuthRoleId
Member of HostInterface.v1_1_1.HostInterface
Description | This property contains the Role for firmware authentication on this interface. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
HostEthernetInterfaces
This is a reference to a collection of NICs that Computer Systems use for network communication with this Host Interface.
HostEthernetInterfaces is a link ("@odata.id": URI
) to another resource.
HostEthernetInterfaces
property is not supported in iLO5.
HostInterfaceType
Member of HostInterface.v1_1_1.HostInterface
Description | This indicates the Host Interface type for this interface. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NetworkHostInterface |
This interface is a Network Host Interface. |
InterfaceEnabled
Member of HostInterface.v1_1_1.HostInterface
Description | This indicates whether this interface is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
KernelAuthEnabled
Member of HostInterface.v1_1_1.HostInterface
Description | This indicates whether this kernel authentication is enabled for this interface. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
KernelAuthRoleId
Member of HostInterface.v1_1_1.HostInterface
Description | This property contains the Role for kernel authentication on this interface. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
ManagerEthernetInterface
This is a reference to a single NIC that this Manager uses for network communication with this Host Interface.
ManagerEthernetInterface is a link ("@odata.id": URI
) to another resource.
NetworkProtocol
This is a reference to the network services and their settings that the Manager controls. It is here that clients will find network configuration options as well as network services.
NetworkProtocol is a link ("@odata.id": URI
) to another resource.
Status
Member of HostInterface.v1_1_1.HostInterface See the Redfish standard schema and specification for information on common Status object.
HostInterfaceCollection.HostInterfaceCollection
@odata.type: "#HostInterfaceCollection.HostInterfaceCollection"
A Collection of HostInterface resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/hostinterfaces |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HostInterface |
Members (array)
Member of HostInterfaceCollection.HostInterfaceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HostInterfaceCollection.HostInterfaceCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HostInterfaceCollection.HostInterfaceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment
@odata.type: "#HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment"
The HpeAutomaticCertEnrollment resource describes the properties of automatic Certificate Enrollment feature support.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice/automaticcertificateenrollment |
GET POST PATCH |
AutomaticCertificateEnrollmentSettings
AutomaticCertificateEnrollmentSettings.CACertificateName Member of HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment
Description | This is the name of imported CA(Certificate Authority) Certificate which is used to sign the SSL certificate. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
AutomaticCertificateEnrollmentSettings.CertificateEnrollmentStatus Member of HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment
Description | Enrollment Status of SSL certificate |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
InProgress |
Enrollment request is in progress. |
Success |
Enrollment has completed successfully. |
Failed |
Enrollment request has failed. |
Disabled |
|
Unknown |
Enrollment request status is Unknown. |
AutomaticCertificateEnrollmentSettings.ChallengePassword Member of HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment
Description | Challenge Password required to complete certificate Enrollment. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
AutomaticCertificateEnrollmentSettings.ServerUrl Member of HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment
Description | Link to Certificate Enrollment Server. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | uri-reference |
AutomaticCertificateEnrollmentSettings.ServiceEnabled Member of HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment
Description | This indicates whether this Automatic Certificate Enrollment(ACE) service is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
HttpsCertCSRSubjectValue
HttpsCertCSRSubjectValue.City Member of HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment
Description | The city or locality where the company or organization that owns this iLO subsystem is located. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
HttpsCertCSRSubjectValue.CommonName Member of HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment
Description | The FQDN of this iLO subsystem. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
HttpsCertCSRSubjectValue.Country Member of HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment
Description | The two-character country code where the company or organization that owns this Manager subsystem is located. Eg: US |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
HttpsCertCSRSubjectValue.IncludeIP Member of HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment
Description | Include the IP Addresses in the CSR. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
HttpsCertCSRSubjectValue.OrgName Member of HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment
Description | The name of the company or organization that owns this iLO subsystem. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
HttpsCertCSRSubjectValue.OrgUnit Member of HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment
Description | The unit within the company or organization that owns this iLO subsystem. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
HttpsCertCSRSubjectValue.State Member of HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment
Description | The state where the company or organization that owns this iLO subsystem is located. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Actions
HpeAutomaticCertEnrollment.ImportCACertificate Member of HpeAutomaticCertEnrollment.v1_0_0.HpeAutomaticCertEnrollment Imports a CA Certificate.
Parameters:
Certificate (string)
Contains PEM formatted X509 certificate (Base64 encoded).
HpeBaseConfigs.v2_0_0.HpeBaseConfigs
@odata.type: "#HpeBaseConfigs.v2_0_0.HpeBaseConfigs"
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/Systems/{item}/Bios/Kmsconfig/Baseconfigs |
GET |
/redfish/v1/Systems/{item}/Bios/Serverconfiglock/Baseconfigs |
GET |
/redfish/v1/systems/{item}/bios/baseconfigs |
GET |
/redfish/v1/systems/{item}/bios/boot/baseconfigs |
GET |
/redfish/v1/systems/{item}/bios/iscsi/baseconfigs |
GET |
/redfish/v1/systems/{item}/bios/tlsconfig/baseconfigs |
GET |
BaseConfigs (array)
Member of HpeBaseConfigs.v2_0_0.HpeBaseConfigs
BaseConfigs
is an array containing elements of:
BaseConfigs[{item}]
Capabilities
Capabilities.BaseConfig Member of HpeBaseConfigs.v2_0_0.HpeBaseConfigs
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Capabilities.BaseConfigs Member of HpeBaseConfigs.v2_0_0.HpeBaseConfigs
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
HpeBiosMapping.v2_0_0.HpeBiosMapping
@odata.type: "#HpeBiosMapping.v2_0_0.HpeBiosMapping"
This is the schema definition for the BIOS Attributes Mappings resource.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bios/mappings |
GET |
AttributeRegistry
Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Description | The Resource ID of the Attribute Registry for the BIOS Attributes resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
BiosPciSettingsMappings (array)
Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
BiosPciSettingsMappings
is an array containing elements of:
BiosPciSettingsMappings[{item}].Associations (array)
Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Associations
is an array containing elements of:
Associations[{item}] BiosPciSettingsMappings[{item}].CorrelatableID Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Description | Contains any CorrelatableIDs that represent this PCI device. The CorrelatableID values can be JSON Pointers or UEFI identifiers. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
BiosPciSettingsMappings[{item}].Instance Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Description | The instance number of the parent PCI device for this association set. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BiosPciSettingsMappings[{item}].Subinstances (array)
Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Subinstances
is an array containing elements of:
Subinstances[{item}].Associations (array)
Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Associations
is an array containing elements of:
Associations[{item}] Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Subinstances[{item}].CorrelatableID Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Description | Contains any CorrelatableIDs that represent this PCI device. The CorrelatableID values can be JSON Pointers or UEFI identifiers. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Subinstances[{item}].Subinstance Member of HpeBiosMapping.v2_0_0.HpeBiosMapping
Description | The sub-instance number of the child PCI device for this association set. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeCertAuth.v1_1_0.HpeCertAuth
@odata.type: "#HpeCertAuth.v1_1_0.HpeCertAuth"
The HpeCertAuth resource describes the BMC certificate based authentication feature.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice/certificateauthentication |
GET POST PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
CACertificates |
Collection of HpeCertificate |
Links/UserCertificateMapping |
Collection of HpeiLOAccountCertificateMap |
CACertificates
The value of this property shall be a reference to a Collection of HpeCertificate resources.
CACertificates is a link ("@odata.id": URI
) to another resource.
CRLIssuer
Member of HpeCertAuth.v1_1_0.HpeCertAuth
Description | Issuer of the installed CRL, if present. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
CRLSerial
Member of HpeCertAuth.v1_1_0.HpeCertAuth
Description | Serial Number of the installed CRL, if present. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
CertificateLoginEnabled
Member of HpeCertAuth.v1_1_0.HpeCertAuth
Description | Specifies whether Certificate login is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
LDAPCertificateNameMapping
Member of HpeCertAuth.v1_1_0.HpeCertAuth
Description | The method used to map a certificate to its associated LDAP user account. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
SubjectCN |
The CN portion of the certificate subject will be used as the LDAP username. |
SubjectDN |
The fully qualified DN of the certificate subject will be used as the LDAP username. |
SANRFC822 |
The RFC822 name from the certificate’s subjectAlternativeName extension will be used as the LDAP username. |
SANUPN |
The UserPrincipalName from the certificate’s subjectAlternativeName extension will be used as the LDAP username. |
OCSPUri
Member of HpeCertAuth.v1_1_0.HpeCertAuth
Description | URL to use for OCSP certificate checking. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Format | uri-reference |
StrictCACModeEnabled
Member of HpeCertAuth.v1_1_0.HpeCertAuth
Description | Whether or not Strict CAC Mode is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Actions
HpeCertAuth.DeleteCRL Member of HpeCertAuth.v1_1_0.HpeCertAuth Remove an installed Certificate Revocation List (CRL).
There are no parameters for this action.
HpeCertAuth.ImportCRL Member of HpeCertAuth.v1_1_0.HpeCertAuth Imports a Certificate Revocation List (CRL).
Parameters:
ImportUri (string)
Contains URI of PEM formatted certificate revocation list (CRL) (Base64 encoded).
HpeCertAuth.ImportCACertificate Member of HpeCertAuth.v1_1_0.HpeCertAuth Imports a Trusted Certificate
Parameters:
Certificate (string)
Contains PEM formatted X509 certificate or PKCS7 certificate chain (Base64 encoded).
HpeCertificate.v1_0_0.HpeCertificate
@odata.type: "#HpeCertificate.v1_0_0.HpeCertificate"
The HpeCertificate resource describes an X509 certificate.
This resource type was added in iLO 5 1.20
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/eventservice/cacertificates/{item} |
GET DELETE |
/redfish/v1/managers/{item}/securityservice/certificateauthentication/cacertificates/{item} |
GET DELETE |
Issuer
Member of HpeCertificate.v1_0_0.HpeCertificate
Description | The Certificate Authority that issued the certificate. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
SerialNumber
Member of HpeCertificate.v1_0_0.HpeCertificate
Description | The serial number that the Certificate Authority assigned to the certificate. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Subject
Member of HpeCertificate.v1_0_0.HpeCertificate
Description | The entity to which the certificate was issued. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
ValidNotAfter
Member of HpeCertificate.v1_0_0.HpeCertificate
Description | The date on which the certificate validity period ends. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
ValidNotBefore
Member of HpeCertificate.v1_0_0.HpeCertificate
Description | The date on which the certificate validity period begins. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
HpeCertificateCollection.HpeCertificateCollection
@odata.type: "#HpeCertificateCollection.HpeCertificateCollection"
A Collection of HpeCertificate resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/eventservice/cacertificates |
GET |
/redfish/v1/managers/{item}/securityservice/certificateauthentication/cacertificates |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeCertificate |
Members (array)
Member of HpeCertificateCollection.HpeCertificateCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeCertificateCollection.HpeCertificateCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeCertificateCollection.HpeCertificateCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeComponent.v1_0_1.HpeComponent
@odata.type: "#HpeComponent.v1_0_1.HpeComponent"
The HpeComponent resource describes a software or firmware update component.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/componentrepository/{item} |
GET PATCH DELETE |
Activates
Member of HpeComponent.v1_0_1.HpeComponent
Description | Indicates when a component becomes active after being updated. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Immediately |
The update activates immediately. |
AfterReboot |
The update activates after a host server reboot. |
AfterDeviceReset |
The update activates after a device reset. |
AfterHardPowerCycle |
The update activates after a full power supply disconnect or E-Fuse reset. |
ComponentType
Member of HpeComponent.v1_0_1.HpeComponent
Description | HTTP-style content-type of binary |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
ComponentUri
Member of HpeComponent.v1_0_1.HpeComponent
Description | URI of the component binary. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Configuration
Member of HpeComponent.v1_0_1.HpeComponent
Description | string defining customized parameters for some components provided by client at upload time and given to the component at execution time (Type D only). |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Created
Member of HpeComponent.v1_0_1.HpeComponent
Description | ISO 8601 time string indicating when this component was added to the NAND. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Criticality
Member of HpeComponent.v1_0_1.HpeComponent
Criticality
Member of HpeComponent.v1_0_1.HpeComponent
Criticality
Member of HpeComponent.v1_0_1.HpeComponent
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Optional |
Recommended |
Critical |
DeviceClass
Member of HpeComponent.v1_0_1.HpeComponent
Description | Device type GUID from iLO secure flash header |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
ExecutionParameters
Member of HpeComponent.v1_0_1.HpeComponent
Description | Client supplied execution parameters. These are supplied at upload time and given to the component at execution time (Type D only). |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Filename
Member of HpeComponent.v1_0_1.HpeComponent
Description | The unique filename of the component. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Filepath
Member of HpeComponent.v1_0_1.HpeComponent
Description | Path of file on the USB LUN if you mount the repo as USB. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Locked
Member of HpeComponent.v1_0_1.HpeComponent
Description | If true, this component cannot be removed with DELETE because it is referenced by an Install Set |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
SizeBytes
Member of HpeComponent.v1_0_1.HpeComponent
Description | Size of the component file in bytes. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Targets (array)
Member of HpeComponent.v1_0_1.HpeComponent
Targets
is an array containing elements of:
Targets[{item}] Member of HpeComponent.v1_0_1.HpeComponent
Description | Target GUIDs from secure flash header or sidecar file. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
UpdatableBy (array)
Member of HpeComponent.v1_0_1.HpeComponent
UpdatableBy
is an array containing elements of:
UpdatableBy[{item}] Member of HpeComponent.v1_0_1.HpeComponent
Description | Describes which types of update agents may apply this component. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Uefi |
This component may be scheduled for update by UEFI BIOS. |
RuntimeAgent |
This component may be scheduled for update by a runtime update agent such as Smart Update Manager or Smart Update Tool. |
Bmc |
This component may be scheduled for update by iLO. |
Version
Member of HpeComponent.v1_0_1.HpeComponent
Description | Version of the component from secure flash header or sidecar file. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
HpeComponentCollection.HpeComponentCollection
@odata.type: "#HpeComponentCollection.HpeComponentCollection"
A Collection of HpeComponent resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/componentrepository |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeComponent |
Members (array)
Member of HpeComponentCollection.HpeComponentCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeComponentCollection.HpeComponentCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeComponentCollection.HpeComponentCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ComponentCount
Member of HpeComponentCollection.HpeComponentCollection
Description | The number of files reported. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.FreeSizeBytes
Member of HpeComponentCollection.HpeComponentCollection
Description | The available repository space in bytes. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.TotalSizeBytes
Member of HpeComponentCollection.HpeComponentCollection
Description | The total repository size in bytes. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
HpeComponentInstallSet.v1_2_0.HpeComponentInstallSet
@odata.type: "#HpeComponentInstallSet.v1_2_0.HpeComponentInstallSet"
The HpeComponentInstallSet resource describes an Install Set, an ordered list of installation instructions that may be invoked.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/installsets/{item} |
GET POST PATCH DELETE |
Created
Member of HpeComponentInstallSet.v1_2_0.HpeComponentInstallSet
Description | ISO-time of install set creation. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
IsRecovery
Member of HpeComponentInstallSet.v1_2_0.HpeComponentInstallSet
Description | If true, this install set is reserved to hold only critical firmware recovery updatable by iLO. Additionally the ‘Administrate Recovery Set’ iLO privilege is required to modify or remove this install set. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Modified
Member of HpeComponentInstallSet.v1_2_0.HpeComponentInstallSet
Description | ISO-time of install modification. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Sequence (array)
Member of HpeComponentInstallSet.v1_2_0.HpeComponentInstallSet
Sequence
is an array containing elements of:
Sequence[{item}].Command Member of HpeComponentInstallSet.v1_2_0.HpeComponentInstallSet
Description | Command to execute. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ApplyUpdate |
Apply an update using the specified component. |
ResetServer |
Reset the server. |
ResetBmc |
Reset the BMC. |
Wait |
Wait for the WaitTimeSeconds number of seconds. |
BootToUefi |
Boot the server to UEFI shell |
PendingReset |
Reset is pending after bundle update. |
Sequence[{item}].Component Member of HpeComponentInstallSet.v1_2_0.HpeComponentInstallSet
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Sequence[{item}].ExecutionTimeoutMinutes Member of HpeComponentInstallSet.v1_2_0.HpeComponentInstallSet
Description | The number of minutes that this update will likely take to apply. Applies if the command is ‘ApplyUpdate’. Ignored otherwise. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Sequence[{item}].Filename Member of HpeComponentInstallSet.v1_2_0.HpeComponentInstallSet
Description | The unique filename of the component. This correlates to ‘Filename’ in the HpeComponent. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Sequence[{item}].UpdatableBy (array)
Member of HpeComponentInstallSet.v1_2_0.HpeComponentInstallSet
UpdatableBy
is an array containing elements of:
UpdatableBy[{item}] Member of HpeComponentInstallSet.v1_2_0.HpeComponentInstallSet
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Bmc |
This component may be scheduled for update by iLO. |
Uefi |
This component may be scheduled for update by UEFI BIOS. |
RuntimeAgent |
This component may be scheduled for update by a runtime update agent such as Smart Update Manager or Smart Update Tool. |
Sequence[{item}].WaitTimeSeconds Member of HpeComponentInstallSet.v1_2_0.HpeComponentInstallSet
Description | The number of seconds to pause if the command is ‘Wait’. Ignored otherwise. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Actions
HpeComponentInstallSet.Invoke Member of HpeComponentInstallSet.v1_2_0.HpeComponentInstallSet
Parameters:
ClearTaskQueue (boolean)
Previous items in the task queue can be cleared before the Install Set is invoked
HpeComponentInstallSetCollection.HpeComponentInstallSetCollection
@odata.type: "#HpeComponentInstallSetCollection.HpeComponentInstallSetCollection"
A Collection of HpeComponentInstallSet resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/installsets |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeComponentInstallSet |
Members (array)
Member of HpeComponentInstallSetCollection.HpeComponentInstallSetCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeComponentInstallSetCollection.HpeComponentInstallSetCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeComponentInstallSetCollection.HpeComponentInstallSetCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
@odata.type: "#HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask"
The HpeComponentUpdateTask resource describes an Update Task, an element in the update task queue. This represents an install instruction.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/updatetaskqueue/{item} |
GET PATCH DELETE |
Command
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Description | Command to execute. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ApplyUpdate |
Apply an update using the specified component. |
ResetServer |
Reset the server. |
ResetBmc |
Reset the BMC. |
Wait |
Wait for the WaitTimeSeconds number of seconds. |
PendingReset |
Reset is pending after bundle update. |
Component
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Created
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Description | ISO-time of task creation (by whomever created this thing) |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
ExecutionTimeoutMinutes
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Description | The number of minutes that this update will likely take to apply. Applies if the command is ‘ApplyUpdate’. Ignored otherwise. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Expire
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Description | ISO 8601 Redfish-style time string after which we will automatically change state to Expired - null for no expire time |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | date-time |
Filename
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Description | The unique filename of the component. This correlates to ‘Filename’ in the HpeComponent. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
MaintenanceWindow
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Description | The maintenance window for this update task. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Modified
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Description | ISO-time of last task queue item update by updater (not client) |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
RecoveryPrivilege
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Description | This task was created by a user with Recovery Set privilege, and would allow a downgrade if ‘DowngradePolicy’ is set to ‘RecoveryDowngrade’. Applies if the command is ‘ApplyUpdate’. Ignored otherwise. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Result
Result.MessageArgs (array)
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
MessageArgs
is an array containing elements of:
MessageArgs[{item}] Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Result.MessageId Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Description | The key for this message that can be used to look up the message in a message registry. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
ResultLog
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Description | base64 encoded entry to capture component log. Estimated to be generally 1-2KB. written by updater |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
StartAfter
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Description | ISO 8601 Redfish-style time string of earliest execution - null for no start time specified |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | date-time |
State
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Description | The current state of the update task. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Pending |
The task is pending execution. |
InProgress |
The task is executing. |
Complete |
The task was completed and the results are available in the Results. |
Expired |
The task will not execute because the current time is after the ‘Expire’ time. |
Exception |
The task was unsuccessful because of an exception condition. |
Canceled |
The task is no longer scheduled to run. |
TPMOverride
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Description | If true then the TPMOverrideFlag is passed in on the associated flash operations. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
UpdatableBy (array)
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
UpdatableBy
is an array containing elements of:
UpdatableBy[{item}] Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Bmc |
This component may be scheduled for update by iLO. |
Uefi |
This component may be scheduled for update by UEFI BIOS. |
RuntimeAgent |
This component may be scheduled for update by a runtime update agent such as Smart Update Manager or Smart Update Tool. |
UpdateRecoverySet
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Description | Update Recovery Set with this component if the command is ‘ApplyUpdate’. Ignored otherwise. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
WaitTimeSeconds
Member of HpeComponentUpdateTask.v1_3_0.HpeComponentUpdateTask
Description | The number of seconds to pause if the command is ‘Wait’. Ignored otherwise. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
HpeComponentUpdateTaskQueueCollection.HpeComponentUpdateTaskQueueCollection
@odata.type: "#HpeComponentUpdateTaskQueueCollection.HpeComponentUpdateTaskQueueCollection"
A Collection of HpeComponentUpdateTaskQueue resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/updatetaskqueue |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeComponentUpdateTask |
Members (array)
Member of HpeComponentUpdateTaskQueueCollection.HpeComponentUpdateTaskQueueCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeComponentUpdateTaskQueueCollection.HpeComponentUpdateTaskQueueCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeComponentUpdateTaskQueueCollection.HpeComponentUpdateTaskQueueCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeDirectoryTest.v1_0_0.HpeDirectoryTest
@odata.type: "#HpeDirectoryTest.v1_0_0.HpeDirectoryTest"
The HpeDirectoryTest resource describes the BMC directory test.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/directorytest |
GET POST |
OverallStatus
Member of HpeDirectoryTest.v1_0_0.HpeDirectoryTest
Description | Represents the overall status of directory tests. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NotRun |
The Overall Directory Test was not run. |
InProgress |
The Overall Directory Test is in progress. |
Success |
The Overall Directory Test has completed successfully. |
Warning |
The Overall Directory Test has completed with warning. |
Failed |
The Overall Directory Test has failed. |
Error |
The Directory Test has encountered an error condition. |
TestResults (array)
Member of HpeDirectoryTest.v1_0_0.HpeDirectoryTest
TestResults
is an array containing elements of:
TestResults[{item}].Notes Member of HpeDirectoryTest.v1_0_0.HpeDirectoryTest
Description | This provides additional details on the directory test. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
TestResults[{item}].Status Member of HpeDirectoryTest.v1_0_0.HpeDirectoryTest See the Redfish standard schema and specification for information on common Status object.
TestResults[{item}].TestName Member of HpeDirectoryTest.v1_0_0.HpeDirectoryTest
Description | The name of directory test. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Actions
HpeDirectoryTest.StartTest Member of HpeDirectoryTest.v1_0_0.HpeDirectoryTest Start the directory test.
Parameters:
HpeESKM.v2_0_0.HpeESKM
@odata.type: "#HpeESKM.v2_0_0.HpeESKM"
The HpeESKM resource describes properties for managing the ESKM feature. ESKM (Enterprise Security Key Manager) enables connections to an operational key manager,change redundancy settings,view the key manager connection settings,test the connection,and view key management events.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice/eskm |
GET POST PATCH |
ESKMEvents (array)
Member of HpeESKM.v2_0_0.HpeESKM
ESKMEvents
is an array containing elements of:
ESKMEvents[{item}].Event Member of HpeESKM.v2_0_0.HpeESKM
Description | ESKM event description. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ESKMEvents[{item}].Timestamp Member of HpeESKM.v2_0_0.HpeESKM
Description | Time of ESKM event. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
KeyManagerConfig
KeyManagerConfig.AccountGroup Member of HpeESKM.v2_0_0.HpeESKM
Description | Account group on ESKM. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
KeyManagerConfig.AccountName Member of HpeESKM.v2_0_0.HpeESKM
Description | Account name on ESKM. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
KeyManagerConfig.ESKMLocalCACertificateName Member of HpeESKM.v2_0_0.HpeESKM
Description | This is the name of Local CA (Certificate Authority) in ESKM that is used to sign the ESKM server certificate. iLO will retrieve this certificate from the ESKM server. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
KeyManagerConfig.ImportedCertificateIssuer Member of HpeESKM.v2_0_0.HpeESKM
Description | Imported certificate issuer. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
KeyManagerConfig.ImportedCertificateSubject Member of HpeESKM.v2_0_0.HpeESKM
Description | Imported certificate subject. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
KeyManagerConfig.LoginName Member of HpeESKM.v2_0_0.HpeESKM
Description | ESKM administrator account login name. This property always returns null on GET. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
KeyManagerConfig.Password Member of HpeESKM.v2_0_0.HpeESKM
Description | ESKM administrator account password. This property always returns null on GET. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
KeyServerRedundancyReq
Member of HpeESKM.v2_0_0.HpeESKM
Description | If true encryption keys will be maintained on both the configured key servers. When this option is disabled, iLO will not verify that encryption keys are copied to both of the configured key servers. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
PrimaryKeyServerAddress
Member of HpeESKM.v2_0_0.HpeESKM
Description | Primary key server IP address or FQDN. Set to null to clear the value. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
PrimaryKeyServerPort
Member of HpeESKM.v2_0_0.HpeESKM
Description | Primary key server port number. Set to null to clear the value. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
SecondaryKeyServerAddress
Member of HpeESKM.v2_0_0.HpeESKM
Description | Secondary key server IP address or FQDN. Set to null to clear the value. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
SecondaryKeyServerPort
Member of HpeESKM.v2_0_0.HpeESKM
Description | Secondary key server port number. Set to null to clear the value. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Actions
HpeESKM.ClearESKMLog Member of HpeESKM.v2_0_0.HpeESKM Clears ESKM log.
There are no parameters for this action.
HpeESKM.TestESKMConnections Member of HpeESKM.v2_0_0.HpeESKM Test ESKM connections.
There are no parameters for this action.
HpeHttpsCert.v2_0_0.HpeHttpsCert
@odata.type: "#HpeHttpsCert.v2_0_0.HpeHttpsCert"
The HpeHttpsCert resource describes an X509 certificate.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice/httpscert |
GET POST DELETE |
CertificateSigningRequest
Member of HpeHttpsCert.v2_0_0.HpeHttpsCert
Description | GenerateCSR action, wait few minutes (upto 10), perform GET operation, fills CSR. Contains a public and private key pair. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
X509CertificateInformation
X509CertificateInformation.Issuer Member of HpeHttpsCert.v2_0_0.HpeHttpsCert
Description | The Certificate Authority that issued the certificate. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
X509CertificateInformation.SerialNumber Member of HpeHttpsCert.v2_0_0.HpeHttpsCert
Description | The serial number that the Certificate Authority assigned to the certificate. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
X509CertificateInformation.Subject Member of HpeHttpsCert.v2_0_0.HpeHttpsCert
Description | The entity to which the certificate was issued. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
X509CertificateInformation.ValidNotAfter Member of HpeHttpsCert.v2_0_0.HpeHttpsCert
Description | The date on which the certificate validity period ends. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
X509CertificateInformation.ValidNotBefore Member of HpeHttpsCert.v2_0_0.HpeHttpsCert
Description | The date on which the certificate validity period begins. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Actions
HpeHttpsCert.ImportCertificate Member of HpeHttpsCert.v2_0_0.HpeHttpsCert Imports a Trusted Certificate and iLO is reset.
Parameters:
Certificate (string)
Contains PEM formatted X509 certificate (Base64 encoded).
HpeHttpsCert.GenerateCSR Member of HpeHttpsCert.v2_0_0.HpeHttpsCert
Parameters:
City (string)
The city or locality where the company or organization that owns this iLO subsystem is located.
OrgName (string)
The name of the company or organization that owns this iLO subsystem.
Country (string)
The two-character country code where the company or organization that owns this Manager subsystem is located. Eg: US
CommonName (string)
The FQDN of this iLO subsystem.
IncludeIP (boolean)
Include the IP Addresses in the CSR.
OrgUnit (string)
The unit within the company or organization that owns this iLO subsystem.
State (string)
The state where the company or organization that owns this iLO subsystem is located.
HpeiLOAccountCertificateMap.v1_0_1.HpeiLOAccountCertificateMap
@odata.type: "#HpeiLOAccountCertificateMap.v1_0_1.HpeiLOAccountCertificateMap"
The HpeiLOAccountCertificateMap resource describes mapping X509 certificates to user accounts.
This resource type was added in iLO 5 1.20
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/usercertificatemapping/{item} |
GET POST DELETE |
Fingerprint
Member of HpeiLOAccountCertificateMap.v1_0_1.HpeiLOAccountCertificateMap
Description | The fingerprint which uniquely identifies the mapped certificate. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
FingerprintDigestAlgorithm
Member of HpeiLOAccountCertificateMap.v1_0_1.HpeiLOAccountCertificateMap
Description | The algorithm used to calculate the fingerprint. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
UserName
Member of HpeiLOAccountCertificateMap.v1_0_1.HpeiLOAccountCertificateMap
Description | The name used to log in to the management processor. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
HpeiLOAccountCertificateMapCollection.HpeiLOAccountCertificateMapCollection
@odata.type: "#HpeiLOAccountCertificateMapCollection.HpeiLOAccountCertificateMapCollection"
A Collection of HpeiLOAccountCertificateMap resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/usercertificatemapping |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeiLOAccountCertificateMap |
Members (array)
Member of HpeiLOAccountCertificateMapCollection.HpeiLOAccountCertificateMapCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeiLOAccountCertificateMapCollection.HpeiLOAccountCertificateMapCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeiLOAccountCertificateMapCollection.HpeiLOAccountCertificateMapCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
@odata.type: "#HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem"
The HpeiLOActiveHealthSystem resource describes the properties for managing the Active Health System.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/activehealthsystem |
GET POST PATCH |
AHSEnabled
Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Description | Determines whether HPE Active Health System logging is enabled or disabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
AHSFileEnd
Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Description | The end of the AHS log. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
AHSFileStart
Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Description | The start of the AHS log. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
AHSStatus
AHSStatus.HardwareEnabled Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Description | Determines whether HPE Active Health System logging in hardware is enabled or not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
AHSStatus.SoftwareEnabled Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Description | Determines whether HPE Active Health System logging in software is enabled or not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
AHSStatus.TemporaryHoldEnabled Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Description | Determines whether HPE Active Health System logging access is temporarily disabled. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LocationParameters
LocationParameters.case_no Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Description | This query parameter may be added to the AHS location URI to insert the case number into the AHS log header. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?downloadAll=1&&case_no=abc123. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
LocationParameters.co_name Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Description | This query parameter may be added to the AHS location URI to insert the company name into the AHS log header. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?downloadAll=1&&co_name=myCompany. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
LocationParameters.contact_name Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Description | This query parameter may be added to the AHS location URI to insert the contact name into the AHS log header. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?downloadAll=1&&contact_name=JohnDoe. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
LocationParameters.days Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Description | This query parameter should be used to download the most recent N days of the AHS log. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?days=7. Will retrive logs made within the last 7 days. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
LocationParameters.downloadAll Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Description | This query parameter should be used to download entire AHS log. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?downloadAll=1. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
LocationParameters.email Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Description | This query parameter may be added to the AHS location URI to insert the contacts email address into the AHS log header. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?downloadAll=1&&email=abc@xyz.com. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
LocationParameters.from Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Description | This query parameter must be added with the ‘to’ query parameter to the AHS location URI to limit the range of data returned. ‘downloadAll’ parameter should not be used with this query parameter. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?from=2014-03-01&&to=2014-03-30. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
LocationParameters.phone Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Description | This query parameter may be added to the AHS location URI to insert the contacts phone number into the AHS log header. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?downloadAll=1&&contact_name=JohnDoe&&phone=555-555-5555. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
LocationParameters.to Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Description | This query parameter must be added with the ‘from’ query parameter to the AHS location URI to limit the range of data returned.‘downloadAll’ parameter should not be used with this query parameter. For example, http://iloname.example.net/ahsdata/HPE_xxxxxxxxxx_20140821.ahs?from=2014-03-01&&to=2014-03-30. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Actions
HpeiLOActiveHealthSystem.LogAmplifierData Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Parameters:
iLOAmplifierName (string)
Name of the iLO Amplifier instance that manages this iLO.
iLOAmplifierManagesCount (integer)
Number of iLOs that this Amplifier instance manages.
HpeiLOActiveHealthSystem.CaptureSystemLog Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem There are no parameters for this action.
HpeiLOActiveHealthSystem.LogMilestone Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem
Parameters:
MilestoneDescription (string)
Description of milestone.
MilestoneOrigin (string)
Origin of milestone.
HpeiLOActiveHealthSystem.ClearLog Member of HpeiLOActiveHealthSystem.v2_5_0.HpeiLOActiveHealthSystem There are no parameters for this action.
HpeiLOBackupFile.v1_0_0.HpeiLOBackupFile
@odata.type: "#HpeiLOBackupFile.v1_0_0.HpeiLOBackupFile"
The HpeiLOBackupFile resource describes the properties for managing BMC backup files.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/backuprestoreservice/backupfiles/{item} |
GET POST DELETE |
Created
Member of HpeiLOBackupFile.v1_0_0.HpeiLOBackupFile
Description | ISO-time of backup file creation (by whomever created this thing) |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
FileSize
Member of HpeiLOBackupFile.v1_0_0.HpeiLOBackupFile
Description | Size of backup file. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
FirmwareVersion
Member of HpeiLOBackupFile.v1_0_0.HpeiLOBackupFile
Description | iLO firmware version running when this backup file was created. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Actions
HpeiLOBackupFile.Restore Member of HpeiLOBackupFile.v1_0_0.HpeiLOBackupFile There are no parameters for this action.
HpeiLOBackupFileCollection.HpeiLOBackupFileCollection
@odata.type: "#HpeiLOBackupFileCollection.HpeiLOBackupFileCollection"
A Collection of HpeiLOBackupFile resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/backuprestoreservice/backupfiles |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeiLOBackupFile |
Members (array)
Member of HpeiLOBackupFileCollection.HpeiLOBackupFileCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeiLOBackupFileCollection.HpeiLOBackupFileCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeiLOBackupFileCollection.HpeiLOBackupFileCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.BackupFileCount
Member of HpeiLOBackupFileCollection.HpeiLOBackupFileCollection
Description | The number of backup files reported. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.BackupFilesAllowed
Member of HpeiLOBackupFileCollection.HpeiLOBackupFileCollection
Description | The number of backup files supported. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
HpeiLOBackupRestoreService.v2_2_0.HpeiLOBackupRestoreService
@odata.type: "#HpeiLOBackupRestoreService.v2_2_0.HpeiLOBackupRestoreService"
The HpeiLOBackupRestoreService resource describes the properties for using the BMC backup and restore features.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/backuprestoreservice |
GET PATCH |
BackupFileLocation
Member of HpeiLOBackupRestoreService.v2_2_0.HpeiLOBackupRestoreService
Description | The URI to which a client may POST to create and download a file for a subsequent restore operation. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
BackupFiles
Link to backup files.
BackupFiles is a link ("@odata.id": URI
) to another resource.
CustomBackupandRestore
Member of HpeiLOBackupRestoreService.v2_2_0.HpeiLOBackupRestoreService
Description | This property indicates whether a custom backup and restore is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.10 |
HttpPushUri
Member of HpeiLOBackupRestoreService.v2_2_0.HpeiLOBackupRestoreService
Description | The URI to which a client may POST a file for a subsequent restore operation. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
HpeiLODateTime.v2_0_0.HpeiLODateTime
@odata.type: "#HpeiLODateTime.v2_0_0.HpeiLODateTime"
The HpeiLODateTime resource describes the properties for managing the BMC data and time.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/datetime |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Links/EthernetNICs |
Collection of EthernetInterface |
ConfigurationSettings
Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The state of the currently displayed configuration settings. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Current |
SomePendingReset |
DateTime
Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The date and time used by management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
NTPServers (array)
Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
NTPServers
is an array containing elements of:
NTPServers[{item}] Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The current NTP server’s IPv4 address, IPv6 address, or FQDN. The value either comes from DHCP or is static depending on the DHCP settings. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PropagateTimeToHost
Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | Determines whether the server time is synchronized with the management processor time during the first POST after AC power is applied. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
StaticNTPServers (array)
Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
StaticNTPServers
is an array containing elements of:
StaticNTPServers[{item}] Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The static NTP server’s IPv4 address, IPv6 address, or FQDN. To set this property, management processor must not be configured to use NTP servers provided by DHCPv4 or DHCPv6. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
TimeZone
TimeZone.Index Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The index of the current time zone. To set a new time zone, specify a different time zone index. This property can be set only when DHCPv4 or DHCPv6 supplied time settings are disabled. Since the time zone list might vary from one firmware version to another (which often leads to differences in time zone indices), setting the time zone by name is recommended over setting by index, for better compatibility. |
Type | number |
Read Only | False |
Added | iLO6 1.05 |
TimeZone.UtcOffset Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The UTC offset of the current time zone, in the format {+/-}hh:mm |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
TimeZone.Value Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The environment variable value. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
TimeZoneList (array)
Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
TimeZoneList
is an array containing elements of:
TimeZoneList[{item}].Index Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The time zone index. |
Type | number |
Read Only | True |
Added | iLO6 1.05 |
TimeZoneList[{item}].UtcOffset Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The UTC offset of the time zone, in the format {+/-}hh:mm |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
TimeZoneList[{item}].Value Member of HpeiLODateTime.v2_0_0.HpeiLODateTime
Description | The environment variable value. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
HpeiLOEmbeddedMedia.v2_0_0.HpeiLOEmbeddedMedia
@odata.type: "#HpeiLOEmbeddedMedia.v2_0_0.HpeiLOEmbeddedMedia"
The HpeiLOEmbeddedMedia resource describes the properties for the embedded media.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/embeddedmedia |
GET |
Controller
Controller.Firmware Controller.Firmware.Current Controller.Firmware.Current.VersionString Member of HpeiLOEmbeddedMedia.v2_0_0.HpeiLOEmbeddedMedia
Description | The current version of the embedded media controller. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Controller.Status Member of HpeiLOEmbeddedMedia.v2_0_0.HpeiLOEmbeddedMedia See the Redfish standard schema and specification for information on common Status object.
SDCard
SDCard.SizeMB Member of HpeiLOEmbeddedMedia.v2_0_0.HpeiLOEmbeddedMedia
Description | The size of the SD card present in the server, in MB. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
SDCard.Status Member of HpeiLOEmbeddedMedia.v2_0_0.HpeiLOEmbeddedMedia See the Redfish standard schema and specification for information on common Status object.
HpeiLOFederatedGroupCapping.v2_0_0.HpeiLOFederatedGroupCapping
@odata.type: "#HpeiLOFederatedGroupCapping.v2_0_0.HpeiLOFederatedGroupCapping"
The HpeiLOFederatedGroupCapping resource describes the properties for managing Federated Group Capping.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power/federatedgroupcapping |
GET PATCH |
CapWatts
Member of HpeiLOFederatedGroupCapping.v2_0_0.HpeiLOFederatedGroupCapping
Description | The configured power cap for all servers in a group. This value is 0 if the power cap is not configured. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CapacityWatts
Member of HpeiLOFederatedGroupCapping.v2_0_0.HpeiLOFederatedGroupCapping
Description | The total power supply capacity for all servers in a group. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Groups
Throttle
Member of HpeiLOFederatedGroupCapping.v2_0_0.HpeiLOFederatedGroupCapping
Description | High, Med, or Low based on the percentage of power usage. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
@odata.type: "#HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup"
The HpeiLOFederationGroup resource describes the properties for managing Federation groups.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/federationgroups/{item} |
GET PATCH DELETE |
Key
Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | The password used by the Federation Group. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Privileges
Privileges.HostBIOSConfigPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | Host BIOS configuration privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Privileges.HostNICConfigPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | Host NIC configuration privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Privileges.HostStorageConfigPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | Host Storage configuration privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Privileges.LoginPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | Login privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Privileges.RemoteConsolePriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | Remote console privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Privileges.SystemRecoveryConfigPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | System Recovery configuration privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Privileges.UserConfigPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | User configuration privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Privileges.VirtualMediaPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | Virtual media privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Privileges.VirtualPowerAndResetPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | Virtual power and reset privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Privileges.iLOConfigPriv Member of HpeiLOFederationGroup.v2_0_0.HpeiLOFederationGroup
Description | The management processor configuration privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
HpeiLOFederationGroupCollection.HpeiLOFederationGroupCollection
@odata.type: "#HpeiLOFederationGroupCollection.HpeiLOFederationGroupCollection"
A Collection of HpeiLOFederationGroup resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/federationgroups |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeiLOFederationGroup |
Members (array)
Member of HpeiLOFederationGroupCollection.HpeiLOFederationGroupCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeiLOFederationGroupCollection.HpeiLOFederationGroupCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeiLOFederationGroupCollection.HpeiLOFederationGroupCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeiLOFederationPeers.v2_0_0.HpeiLOFederationPeers
@odata.type: "#HpeiLOFederationPeers.v2_0_0.HpeiLOFederationPeers"
The HpeiLOFederationPeers resource describes the properties for viewing Federation peers.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/federationpeers/{item} |
GET |
Peers (array)
Member of HpeiLOFederationPeers.v2_0_0.HpeiLOFederationPeers
Peers
is an array containing elements of:
Peers[{item}].HttpErrorCode Member of HpeiLOFederationPeers.v2_0_0.HpeiLOFederationPeers
Description | Error code for success or failure. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Peers[{item}].ManagerIPAddress Member of HpeiLOFederationPeers.v2_0_0.HpeiLOFederationPeers
Description | Manager IP address of the federation peer. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Peers[{item}].Time Member of HpeiLOFederationPeers.v2_0_0.HpeiLOFederationPeers
Description | Time when the federation peer was added. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Peers[{item}].URL Member of HpeiLOFederationPeers.v2_0_0.HpeiLOFederationPeers
Description | URL of the federation peer. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | url |
Peers[{item}].UUID Member of HpeiLOFederationPeers.v2_0_0.HpeiLOFederationPeers
Description | UUID peers that are part of the federation group. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
HpeiLOFederationPeersCollection.HpeiLOFederationPeersCollection
@odata.type: "#HpeiLOFederationPeersCollection.HpeiLOFederationPeersCollection"
A Collection of HpeiLOFederationPeers resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/federationpeers |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeiLOFederationPeers |
Members (array)
Member of HpeiLOFederationPeersCollection.HpeiLOFederationPeersCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeiLOFederationPeersCollection.HpeiLOFederationPeersCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeiLOFederationPeersCollection.HpeiLOFederationPeersCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeiLOFrus.v2_0_0.HpeiLOFrus
@odata.type: "#HpeiLOFrus.v2_0_0.HpeiLOFrus"
The HpeiLOFrus resource describes features of add-in adapters.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/basefrus/{item} |
GET |
/redfish/v1/chassis/{item}/basefrus/{item}/details |
GET |
/redfish/v1/chassis/{item}/mezzfrus/{item} |
GET |
/redfish/v1/chassis/{item}/mezzfrus/{item}/details |
GET |
FRU
Member of HpeiLOFrus.v2_0_0.HpeiLOFrus
Description | The typename this FRU describes. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
FRULink
Member of HpeiLOFrus.v2_0_0.HpeiLOFrus
Description | The aggregation of the Link signals for all ports on the FRU card. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
FRUType
Member of HpeiLOFrus.v2_0_0.HpeiLOFrus
Description | The type of FRU that is installed, i.e. Base or Mezzanine FRU. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Base |
Mezzanine |
Interlocked
Member of HpeiLOFrus.v2_0_0.HpeiLOFrus
Description | Indicates if a PCIe card is installed in slot. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Location
Member of HpeiLOFrus.v2_0_0.HpeiLOFrus
Description | The location where the FRU resides. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
PGood
Member of HpeiLOFrus.v2_0_0.HpeiLOFrus
Description | The Power Good status. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
PhysicalSlot
Member of HpeiLOFrus.v2_0_0.HpeiLOFrus
Description | The physical slot in which this FRU resides. 0 is for Base FRU, 1-N is for Mezzanine FRUs |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Seated
Member of HpeiLOFrus.v2_0_0.HpeiLOFrus
Description | Indicates if the Base FRU is properly seated in the slot. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
SerialNumber
Member of HpeiLOFrus.v2_0_0.HpeiLOFrus
Description | The system’s serial number. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
UEFIDeviceName
Member of HpeiLOFrus.v2_0_0.HpeiLOFrus
Description | The Device Name in UTF-8 format. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
UEFIDevicePaths (array)
Member of HpeiLOFrus.v2_0_0.HpeiLOFrus
UEFIDevicePaths
is an array containing elements of:
UEFIDevicePaths[{item}] Member of HpeiLOFrus.v2_0_0.HpeiLOFrus
Type | string |
Read Only | True |
Added | iLO6 1.05 |
HpeiLOFrusCollection.HpeiLOFrusCollection
@odata.type: "#HpeiLOFrusCollection.HpeiLOFrusCollection"
A Collection of HpeiLOFrus resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/basefrus |
GET |
/redfish/v1/chassis/{item}/mezzfrus |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeiLOFrus |
Members (array)
Member of HpeiLOFrusCollection.HpeiLOFrusCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeiLOFrusCollection.HpeiLOFrusCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeiLOFrusCollection.HpeiLOFrusCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeiLOLicense.v2_3_0.HpeiLOLicense
@odata.type: "#HpeiLOLicense.v2_3_0.HpeiLOLicense"
The HpeiLOLicense resource describes the properties for managing BMC licenses.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/licenseservice/{item} |
GET DELETE |
Confirmation
Confirmation.Code Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Confirmation service response code. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Confirmation.Message Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | User-friendly confirmation information for the current managment processor license. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Confirmation.Service Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Confirmation service URI. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Confirmation.Status Member of HpeiLOLicense.v2_3_0.HpeiLOLicense See the Redfish standard schema and specification for information on common Status object.
ConfirmationRequest
ConfirmationRequest.EON ConfirmationRequest.EON.License Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The current license of this management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
ConfirmationRequest.EON.LicenseKey Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The license key installed on this management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
ConfirmationRequest.EON.Quantity Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The number of entitlements licensed. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
ConfirmationRequest.EON.State Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The current licensing state and behavior of the management processor. This is affected by license installation, activation and confirmation. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
unlicensed |
standard baseline functionality |
evaluation |
evaluation / demonstration temporary licensed functionality |
nfr |
not for resale experimental functionality |
expired |
standard baseline functionality and evaluation licenses no longer accepted |
unconfirmed |
licensed functionality that has not been confirmed |
timeout |
licensed functionality is disabled until the license is confirmed |
confirmed |
licensed functionality has been confirmed for use |
static |
system has active built-in licensed functionality that does not require confirmation |
err |
error |
ConfirmationRequest.Signer Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Source of confirmation request. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
ConfirmationRequest.System ConfirmationRequest.System.ChipId Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Management processor unique chip identifier. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
ConfirmationRequest.System.Product Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | System housing management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
ConfirmationRequest.System.SerialNumber Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | System serial number. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
License
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The current license of this management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
LicenseClass
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The class of current license on this management processor. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
FQL |
BETA |
EVALUATION |
AKA |
DL |
FFQL |
SL |
SITE |
EVAL |
MLA |
LicenseErr
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Error information from the most recent attempt to alter the installed management processor license. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
LicenseExpire
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | User-friendly expiration information of the installed management processor license. For example, for demo license, Evaluation period 2 months 5 days 6 hours remain. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures
LicenseFeatures.AutoCertEnroll Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Automatic Certificate Enrollment. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.DirectoryAuth Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Directory integrated authentication. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.DowngradePolicy Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Firmware downgrade policy setting. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.EmailAlert Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Email based alerting. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.FWScan Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Runtime FW Integrity check. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.Federation Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Distributed peer to peer management. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.Jitter Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Jitter Control. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.KD Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Kernel Debugging (VSP raw mode). |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.KeyMgr Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Store and retrieve keys from an external key manager. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.MURC Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Shared Multi-User Remote Console. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.ODIM Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Open Distributed Infrastructure Management. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.PowerReg Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Power Regulator. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.RC Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Graphical Remote Console. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.Recovery Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | OS Recovery Event. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.RemoteSyslog Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Remote Syslog. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.Scrncap Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Video Capture. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.SecureErase Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Secure Erase of embedded media. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.SmartCard Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | 2-Factor Authentication (Smart Card). |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.SuiteB Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | SuiteB/CNSA mode support. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.TextCons Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Text Console. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.VM Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Remote Console based Virtual Media. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.VMScript Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Scripted Virtual Media. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseFeatures.VSPLogging Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | Virtual Serial Port Logging and Playback. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
LicenseInstallDate
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | User-friendly installation date information of the installed management processor license. For example, 19 May 2017 |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
LicenseKey
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | User-visible license key installed on this management processor. License keys are 25 or 29 characters and contain letters, numbers and hypens. Use POST method to collection of membertype HpeiLOLicense to install / update the license. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
LicenseSeats
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The number of systems authorized to use this activation key. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
LicenseTier
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The licensed feature-set of the management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
STD |
BLSTD |
ADV |
BLADV |
ESS |
SCALEOUT |
APSE |
LicenseType
Member of HpeiLOLicense.v2_3_0.HpeiLOLicense
Description | The type of current license activation on this management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Unlicensed |
Evaluation |
Perpetual |
Subscription |
Internal |
Duration |
Expired |
HpeiLOLicenseCollection.HpeiLOLicenseCollection
@odata.type: "#HpeiLOLicenseCollection.HpeiLOLicenseCollection"
A Collection of HpeiLOLicense resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/licenseservice |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeiLOLicense |
Members (array)
Member of HpeiLOLicenseCollection.HpeiLOLicenseCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeiLOLicenseCollection.HpeiLOLicenseCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeiLOLicenseCollection.HpeiLOLicenseCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory
@odata.type: "#HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory"
The HpeiLOResourceDirectory resource describes the resource directory. The resource directory is a selected set of resources and resource types for faster access to resources.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/resourcedirectory |
GET |
Instances (array)
Member of HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory
Instances
is an array containing elements of:
Instances[{item}].@odata.id Member of HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Instances[{item}].@odata.type Member of HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Instances[{item}].ETag Member of HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory
Description | This is the last known etag of the resource. The property is omitted if not known. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Instances[{item}].HttpMethods (array)
Member of HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory
HttpMethods
is an array containing elements of:
HttpMethods[{item}] Member of HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
GET |
HEAD |
POST |
PUT |
PATCH |
DELETE |
Instances[{item}].MemberType Member of HpeiLOResourceDirectory.v2_0_0.HpeiLOResourceDirectory
Description | This property has the type of members for collection resources. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
HpeiLOSecurityDashboard.v1_0_0.HpeiLOSecurityDashboard
@odata.type: "#HpeiLOSecurityDashboard.v1_0_0.HpeiLOSecurityDashboard"
The HpeiLOSecurityDashboard resource describes the BMC security dashboard.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice/securitydashboard |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
SecurityParameters |
HpeiLOSecurityParam |
OverallSecurityStatus
Member of HpeiLOSecurityDashboard.v1_0_0.HpeiLOSecurityDashboard
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Ok |
The Overall security state of the system is OK. |
Risk |
The Overall security state of the system is Risk. |
Ignored |
The user has ignored (or suppressed) the risk on all the security parameters (whose Status value is Risk). |
SecurityParameters
This property references a resource of type Collection with a MemberType of HpeiLOSecurityParam.
SecurityParameters is a link ("@odata.id": URI
) to another resource.
ServerConfigurationLockStatus
Member of HpeiLOSecurityDashboard.v1_0_0.HpeiLOSecurityDashboard
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Server Configuration Lock is Enabled. |
Disabled |
Server Configuration Lock is Disabled. |
HpeiLOSecurityParam.v1_1_0.HpeiLOSecurityParam
@odata.type: "#HpeiLOSecurityParam.v1_1_0.HpeiLOSecurityParam"
The HpeiLOSecurityParam resource describes the properties for BMC security dashboard parameters.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice/securitydashboard/securityparams/{item} |
GET PATCH |
Ignore
Member of HpeiLOSecurityParam.v1_1_0.HpeiLOSecurityParam
Description | This indicates if the security status of the security parameter is set to ignored or not. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
IgnoredBy
Member of HpeiLOSecurityParam.v1_1_0.HpeiLOSecurityParam
Description | This represents the user who changed the value of Ignore. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
IgnoredTime
Member of HpeiLOSecurityParam.v1_1_0.HpeiLOSecurityParam
Description | This represents the time when the risk configuration was suppressed. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
RecommendedAction
Member of HpeiLOSecurityParam.v1_1_0.HpeiLOSecurityParam
Description | This represents the recommended action. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
SecurityStatus
Member of HpeiLOSecurityParam.v1_1_0.HpeiLOSecurityParam
Description | This represents if the status of the security parameter. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Risk |
This indicates a security issue associated with the security parameter. |
Ok |
This indicates no security issue associated with the security parameter. |
State
Member of HpeiLOSecurityParam.v1_1_0.HpeiLOSecurityParam
Description | This represents the state or value of the security parameter. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
On |
The state of the Security Parameter is On. |
Off |
The state of the Security Parameter is Off. |
Enabled |
The state of the Security Parameter is Enabled. |
Disabled |
The state of the Security Parameter is Disabled. |
Failed |
The status of the Security Parameter or the result of an operation represented by the Security Parameter is Failed. |
Ok |
The status of the Security Parameter or the result of an operation represented by the Security Parameter is Ok. |
Insufficient |
The value of the Security Parameter is Insufficient or less than the default value. |
Repaired |
The state of the Security Parameter is Repaired. |
True |
The state of the Security Parameter is True. |
False |
The state of the Security Parameter is False. |
HpeiLOSecurityParamCollection.HpeiLOSecurityParamCollection
@odata.type: "#HpeiLOSecurityParamCollection.HpeiLOSecurityParamCollection"
A Collection of HpeiLOSecurityParam resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice/securitydashboard/securityparams |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeiLOSecurityParam |
Members (array)
Member of HpeiLOSecurityParamCollection.HpeiLOSecurityParamCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeiLOSecurityParamCollection.HpeiLOSecurityParamCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeiLOSecurityParamCollection.HpeiLOSecurityParamCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
@odata.type: "#HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService"
The HpeiLOSnmpService resource describes the properties for managing the SNMP configuration of the BMC.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/snmpservice |
GET POST PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
SNMPUsers |
Collection of HpeSNMPUser |
SNMPAlertDestinations |
Collection of HpeSNMPAlertDestination |
AlertDestinationAssociations (array)
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
AlertDestinationAssociations
is an array containing elements of:
AlertDestinationAssociations[{item}].SNMPAlertProtocol Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | Indicate the SNMP protocol associated with the AlertDestination. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
SNMPv1Trap |
Indicate SNMPv1 trap is enabled for the destination. |
SNMPv3Trap |
Indicate SNMPv3 trap is enabled for the destination. Needs to fill the SecurityName as well. |
SNMPv3Inform |
Indicate SNMPv3 Inform is enabled for the destination. Needs to fill the SecurityName as well. |
Null |
A value is temporarily unavailable |
AlertDestinationAssociations[{item}].SecurityName Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | Provides the SNMPv3 security name associated with the destination when SNMP alert protocol is SNMPv3 trap or inform. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
AlertDestinations (array)
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
AlertDestinations
is an array containing elements of:
AlertDestinations[{item}] Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
AlertsEnabled
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | The alert conditions that the management processor detects independently of the host operating system can be sent to specified SNMP alert destinations. Indicates if the SNMPv1 Trap or SNMPv3 Trap is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Contact
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | The string of up to 49 characters that specifies the system administrator or server owner. The string can include a name, email address, or phone number. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Location
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | The string of up to 49 characters that specifies the physical location of the server. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.SNMPColdStartTrapBroadcast
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | If set to true, the Cold Start Trap will be enabled. The Cold Start Trap is broadcast to a subnet broadcast address if there are no trap destinations configured in the SNMP Alert Destination(s) boxes. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
PeriodicHSATrapConfig
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | If there are any component in health status array(HSA) Trap are in degraded or failed condition then HSA trap will be sent periodically till the component status becomes ok or fine condition. This setting is disabled by default. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Disabled |
Daily |
Weekly |
Monthly |
ReadCommunities (array)
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
ReadCommunities
is an array containing elements of:
ReadCommunities[{item}] Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Role
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | The string of up to 64 characters that describes the server role or function. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
RoleDetail
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | The string of up to 512 characters that describes specific tasks that the server might perform. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
SNMPAlertDestinations
SNMP Alert Destination details.
SNMPAlertDestinations is a link ("@odata.id": URI
) to another resource.
SNMPUsers
SNMPv3 User details.
SNMPUsers is a link ("@odata.id": URI
) to another resource.
SNMPv1Enabled
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | Indicates if the SNMPv1 Query or SNMPv1 Trap is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SNMPv1RequestsEnabled
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | Indicates if the SNMPv1 Query is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.40 |
SNMPv1TrapEnabled
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | Indicates if the SNMPv1 Trap is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.40 |
SNMPv1Traps
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | When enabled, SNMPv1 traps are sent to the remote management systems configured in the SNMP Alert Destination(s) boxes. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SNMPv3EngineID
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | The SNMPv3 Engine ID is the unique identifier of an SNMP engine that belongs to an SNMP agent entity. This value must be a hexadecimal string with an even number of 6 to 32 characters, excluding the first two characters, 0x (for example, 0x01020304abcdef). |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
SNMPv3InformRetryAttempt
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | Specifies the number of retries to be used in SNMPv3 inform. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
SNMPv3InformRetryIntervalSeconds
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | Specifies the interval in seconds between SNMPv3 inform retries. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
SNMPv3RequestsEnabled
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | Indicates if the SNMPv3 Query is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.40 |
SNMPv3TrapEnabled
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | Indicates if the SNMPv3 Trap is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.40 |
Status
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService See the Redfish standard schema and specification for information on common Status object.
TrapCommunities (array)
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
TrapCommunities
is an array containing elements of:
TrapCommunities[{item}] Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Type | string |
Read Only | True |
Added | iLO6 1.05 |
TrapSourceHostname
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | Determines the host name that is used in the SNMP-defined sysName variable when the management processor generates SNMP traps. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Manager |
System |
Users (array)
Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Users
is an array containing elements of:
Users[{item}].AuthPassphrase Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | Sets the passphrase to use for sign operations. Enter a value of 8 to 49 characters. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Users[{item}].AuthProtocol Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | Sets the message digest algorithm to use for encoding the authorization passphrase. The message digest is calculated over an appropriate portion of an SNMP message, and is included as part of the message sent to the recipient. Select MD5 (Message Digest) or SHA (Secure Hash Algorithm). |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
MD5 |
Indicate Message Digest Algorithm. |
SHA |
Indicate Secure Hash Algorithm. |
SHA256 |
Indicate SHA256 Algorithm. |
Null |
A value is temporarily unavailable |
Users[{item}].PrivacyPassphrase Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | Sets the passphrase to use for encrypt operations. Enter a value of 8 to 49 characters. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Users[{item}].PrivacyProtocol Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | Sets the encryption algorithm to use for encoding the privacy passphrase. A portion of an SNMP message is encrypted before transmission. Select AES (Advanced Encryption Standard) or DES (Data Encryption Standard). |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
AES |
Indicate Advanced Encryption Standard Algorithm. |
DES |
Indicate Data Encryption Standard Algorithm. |
Null |
A value is temporarily unavailable |
Users[{item}].SecurityName Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | The user profile name. Enter an alphanumeric string of 1 to 32 characters. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Users[{item}].UserEngineID Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService
Description | The UserEngineID is combined with the SecurityName to create a SNMPv3 user for each manager. It is only used for creating remote accounts used with INFORM messages. If this property is not set then INFORM message will be sent with default or iLO configured engine ID. This value must be a hexadecimal string with an even number of 10 to 64 characters, excluding the first two characters, 0x (for example, 0x01020304abcdef). |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Actions
HpeiLOSnmpService.SendSNMPTestAlert Member of HpeiLOSnmpService.v2_4_0.HpeiLOSnmpService There are no parameters for this action.
HpeiLOSSO.v2_0_0.HpeiLOSSO
@odata.type: "#HpeiLOSSO.v2_0_0.HpeiLOSSO"
The HpeiLOSSO resource describes the configuration of the HPE BMC single-sign-on trusted server feature.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice/sso |
GET POST PATCH |
ManagerTrustedCertificates (array)
Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
ManagerTrustedCertificates
is an array containing elements of:
ManagerTrustedCertificates[{item}].@odata.id Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
ManagerTrustedCertificates[{item}].@odata.type Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Type | string |
Read Only | True |
Added | iLO6 1.05 |
ManagerTrustedCertificates[{item}].Certificate Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Contains PEM formatted X509 certificate (Base64 encoded). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ManagerTrustedCertificates[{item}].CertificateDetails ManagerTrustedCertificates[{item}].CertificateDetails.Issuer Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | The Certificate Authority that issued the certificate. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
ManagerTrustedCertificates[{item}].CertificateDetails.Subject Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | The entity to which the certificate was issued. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
ManagerTrustedCertificates[{item}].CertificateDetails.ValidNotAfter Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | The date on which the certificate validity period ends. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
ManagerTrustedCertificates[{item}].CertificateDetails.ValidNotBefore Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | The date on which the certificate validity period begins. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
ManagerTrustedCertificates[{item}].RecordType Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Specifies the type of SSO record imported. |
Type | string |
Read Only | true |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Certificate |
It is a PEM formatted X509 certificate (Base64 encoded). |
DNSName |
It is a DNS name or an IP address of the HPE SSO-compliant application. |
ManagerTrustedCertificates[{item}].SerialNumber Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Contains the Serial number for the SSO records. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
ManagerTrustedCertificates[{item}].ServerName Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | The Server name (or certificate subject). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ManagerTrustedCertificates[{item}].Status Member of HpeiLOSSO.v2_0_0.HpeiLOSSO See the Redfish standard schema and specification for information on common Status object.
SSOsettings
SSOsettings.AdminPrivilege SSOsettings.AdminPrivilege.HostBIOSConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host BIOS Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.AdminPrivilege.HostNICConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host NIC Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.AdminPrivilege.HostStorageConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host Storage Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.AdminPrivilege.LoginPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Login Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.AdminPrivilege.RemoteConsolePriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Remote Console Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.AdminPrivilege.SystemRecoveryConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | System Recovery Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.AdminPrivilege.UserConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | User Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.AdminPrivilege.VirtualMediaPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Virtual Media Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.AdminPrivilege.VirtualPowerAndResetPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Power and Reset Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.AdminPrivilege.iLOConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | iLO Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.OperatorPrivilege SSOsettings.OperatorPrivilege.HostBIOSConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host BIOS Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.OperatorPrivilege.HostNICConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host NIC Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.OperatorPrivilege.HostStorageConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host Storage Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.OperatorPrivilege.LoginPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Login Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.OperatorPrivilege.RemoteConsolePriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Remote Console Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.OperatorPrivilege.SystemRecoveryConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | System Recovery Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.OperatorPrivilege.UserConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | User Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.OperatorPrivilege.VirtualMediaPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Virtual Media Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.OperatorPrivilege.VirtualPowerAndResetPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Power and Reset Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.OperatorPrivilege.iLOConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | iLO Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.SSOTrustMode Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Represents the SSO Trust Mode. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
TrustNone |
Rejects all SSO connection request. |
TrustAll |
Accepts any SSO connection initiated from any HPE SSO compliant application. |
TrustbyName |
Enables SSO connections from an HPE SSO compliant application by matching a directly imported IP address or DNS name. |
TrustbyCert |
Enables SSO connections from an HPE SSO compliant application by matching a certificate previously imported to iLO. |
SSOsettings.UserPrivilege SSOsettings.UserPrivilege.HostBIOSConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host BIOS Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.UserPrivilege.HostNICConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host NIC Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.UserPrivilege.HostStorageConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Host Storage Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.UserPrivilege.LoginPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Login Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.UserPrivilege.RemoteConsolePriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Remote Console Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.UserPrivilege.SystemRecoveryConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | System Recovery Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.UserPrivilege.UserConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | User Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.UserPrivilege.VirtualMediaPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Virtual Media Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.UserPrivilege.VirtualPowerAndResetPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | Power and Reset Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SSOsettings.UserPrivilege.iLOConfigPriv Member of HpeiLOSSO.v2_0_0.HpeiLOSSO
Description | iLO Configuration Privileges. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Actions
HpeiLOSSO.ImportDNSName Member of HpeiLOSSO.v2_0_0.HpeiLOSSO Add DNS Name to the record list.
Parameters:
DNSName (string)
DNS Name of the HPE SSO Trusted Server.
HpeiLOSSO.ImportCertificate Member of HpeiLOSSO.v2_0_0.HpeiLOSSO Import the HPE SSO Certificate.
Parameters:
CertInput (string)
PEM formatted X509 certificate (Base64 encoded)/DNS name or IP address to import the certificate.
CertType (string)
Specifies the type of certificate imported.
Value | Description |
---|---|
ImportCertUri | iLO imports the certificate from the HPE SSO compliant application over the network. |
DirectImportCert | iLO directly imports the Certificate. |
HpeiLOSSO.DeleteSSORecordbyNumber Member of HpeiLOSSO.v2_0_0.HpeiLOSSO Delete SSO record by record number.
Parameters:
RecordNumber (integer)
Index of the SSO record to be deleted.
HpeiLOSSO.DeleteAllSSORecords Member of HpeiLOSSO.v2_0_0.HpeiLOSSO Delete all the SSO records.
There are no parameters for this action.
HpeInvalidImage.v1_0_0.HpeInvalidImage
@odata.type: "#HpeInvalidImage.v1_0_0.HpeInvalidImage"
The HpeInvalidImage resource describes the properties of an invalid firmware image detected and preserved from a computer system.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/invalidimagerepository/{item} |
GET POST PATCH DELETE |
Created
Member of HpeInvalidImage.v1_0_0.HpeInvalidImage
Description | ISO 8601 time string indicating when this image was added to the NAND. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
DeviceClass
Member of HpeInvalidImage.v1_0_0.HpeInvalidImage
Description | Device type GUID from iLO secure flash header |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Filename
Member of HpeInvalidImage.v1_0_0.HpeInvalidImage
Description | The unique filename of the image. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Filepath
Member of HpeInvalidImage.v1_0_0.HpeInvalidImage
Description | Path of file on the USB LUN if the repo is mounted as USB. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
ImageUri
Member of HpeInvalidImage.v1_0_0.HpeInvalidImage
Description | URI of the image binary. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
SizeBytes
Member of HpeInvalidImage.v1_0_0.HpeInvalidImage
Description | Size of the image file in bytes. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
HpeInvalidImageCollection.HpeInvalidImageCollection
@odata.type: "#HpeInvalidImageCollection.HpeInvalidImageCollection"
A Collection of HpeInvalidImage resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/invalidimagerepository |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeInvalidImage |
Members (array)
Member of HpeInvalidImageCollection.HpeInvalidImageCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeInvalidImageCollection.HpeInvalidImageCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeInvalidImageCollection.HpeInvalidImageCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
@odata.type: "#HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator"
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bios/iscsi |
GET |
/redfish/v1/systems/{item}/bios/iscsi/settings |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
@Redfish.Settings/SettingsObject |
HpeiSCSISoftwareInitiator |
Oem/Hpe/Links/BaseConfigs |
HpeBaseConfigs |
@Redfish.Settings
Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator See the Redfish standard schema and specification for information on common @Redfish properties.
iSCSIInitiatorName
Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The worldwide unique iSCSI Qualified Name (IQN) of this iSCSI Initiator. Only IQN format is accepted. EUI format is not supported (for example, ‘iqn.1986-03.com.hp:init.sn-123456’). |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
iSCSINicSources (array)
Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
iSCSINicSources
is an array containing elements of:
iSCSINicSources[{item}] Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The BIOS Attribute that describes a NIC instance that can be used as a target for iSCSI configuration. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources (array)
Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
iSCSISources
is an array containing elements of:
iSCSISources[{item}].StructuredBootString Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | Identifies this iSCSI option within the server. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].UEFIDevicePath Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | Standardized text representation of the UEFI device path for this option, in UTF-8 format. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSIAttemptInstance Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | Uniquely identifies this iSCSI attempt within iSCSISources array. If set to zero, all other properties in the boot option object are ignored (which will delete an existing boot attempt). |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSIAttemptName Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | Human readable descriptive name for this iSCSI attempt configuration |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSIAuthenticationMethod Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The iSCSI connection authentication method. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
None |
No iSCSI connection security. |
CHAP |
iSCSI connection is secured using Challenge Handshake Authentication Protocol (CHAP). |
iSCSISources[{item}].iSCSIChapSecret Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The password needed for CHAP authentication. This is applicable only when the Authentication Method is set to CHAP, and the CHAP Type is set to Mutual. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSIChapType Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The CHAP authentication type. This is applicable only when the Authentication Method is set to CHAP. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
OneWay |
The target will authenticate the initiator. . |
Mutual |
both the initiator and target will authenticate each other. |
iSCSISources[{item}].iSCSIChapUsername Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The user name needed for CHAP authentication. This is applicable only when the Authentication Method is set to CHAP. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSIConnectRetry Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The number of times to retry the iSCSI connection. Zero means no retries. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSIConnectTimeoutMS Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The iSCSI connection timeout value in milliseconds. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSIConnection Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | Enables or Disables iSCSI mode for a selected iSCSI attempt. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Connecting to this iSCSI attempt is disabled. |
Enabled |
Connecting to this iSCSI attempt is enabled. |
EnabledMpio |
Connecting to this iSCSI attempt is enabled with MPIO (Multi Path I/O). |
iSCSISources[{item}].iSCSIInitiatorGateway Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The gateway address of the iSCSI Initiator, if not configured via DHCP. The address must be an IPv4 or IPv6 address, depending on the IP Address Type. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSIInitiatorInfoViaDHCP Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | If enabled, the iSCSI Initiator information is configured from DHCP. Otherwise, the iSCSI initiator information must be statically configured. When providing static values for the Initiator, ensure Target settings are also configured with static values. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSIInitiatorIpAddress Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The IP Address of the iSCSI Initiator, if not configured via DHCP. The Initiator IP Address is always auto-assigned if IP address type is IPv6. The address must be an IPv4 or IPv6 address, depending on the IP Address Type. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSIInitiatorNetmask Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The subnet mask of the iSCSI Initiator, if not configured via DHCP. The address must be an IPv4. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSIIpAddressType Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The iSCSI IP Address type. If set to Auto, IPv4 will be attempted first, followed by IPv6. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
IPv4 |
The iSCSI IP address is configured in IPv4 format. |
IPv6 |
The iSCSI IP address is configured in IPv6 format. |
Auto |
The iSCSI IP address is configured in IPv4. If an issue occurs with IPv4, then the IPv6 configuration is used. |
iSCSISources[{item}].iSCSILUN Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The iSCSI target Logical Unit Number (LUN), if not obtained from DHCP. This value must follow the SAM-2 spec. E.g. 0001-1234-5678-9ABC. If the digit number is less then 5 characters, a dash character is not required. E.g. 0001. If the lun number is 12345, input 1234-5 |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSINicSource Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | A BIOS Attribute that describes this selected NIC instance. This must match one of the possible values listed in the iSCSINicSources array. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSIReverseChapSecret Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The password needed for reverse CHAP authentication (from the target to the initiator). This is applicable only when the Authentication Method is set to CHAP, and the CHAP Type is set to Mutual. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSIReverseChapUsername Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | User Name for reverse CHAP authentication (from the target to the initiator). This is applicable only when the Authentication Method is set to CHAP, and the CHAP Type is set to Mutual. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSITargetInfoViaDHCP Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | If enabled, the iSCSI target information are configured from DHCP. Otherwise, the iSCSI target information must be statically configured. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSITargetIpAddress Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The IP Address of the iSCSI Target, if not obtained from DHCP. The address must be an IPv4 or IPv6 address, depending on the IP Address Type. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSITargetName Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The worldwide unique iSCSI Qualified Name (IQN) of this iSCSI target. Only the IQN format is accepted. EUI format is not supported (for example, ‘iqn.1991-05.com.microsoft:iscsitarget-iscsidisk-target’). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
iSCSISources[{item}].iSCSITargetTcpPort Member of HpeiSCSISoftwareInitiator.v2_0_0.HpeiSCSISoftwareInitiator
Description | The iSCSI Target TCP Port number, if not obtained from DHCP. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeKmsConfig.v1_0_0.HpeKmsConfig
@odata.type: "#HpeKmsConfig.v1_0_0.HpeKmsConfig"
The schema definition for Key Management Service configuration.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/Systems/{item}/Bios/Kmsconfig/Settings |
GET PATCH |
/redfish/v1/systems/{item}/bios/Kmsconfig |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
@Redfish.Settings/SettingsObject |
HpeKmsConfig |
Oem/Hpe/Links/BaseConfigs |
HpeBaseConfigs |
@Redfish.Settings
Member of HpeKmsConfig.v1_0_0.HpeKmsConfig See the Redfish standard schema and specification for information on common @Redfish properties.
DeleteUnusedEncryptionKeys
Member of HpeKmsConfig.v1_0_0.HpeKmsConfig
Description | Removes unused encryption keys. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Do not removed unused encryption keys. |
Enabled |
Remove unused encryption keys. |
EncryptableDevices (array)
Member of HpeKmsConfig.v1_0_0.HpeKmsConfig
EncryptableDevices
is an array containing elements of:
EncryptableDevices[{item}].DeviceName Member of HpeKmsConfig.v1_0_0.HpeKmsConfig
Description | Name of the encryptable device. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
EncryptableDevices[{item}].EncryptionAction Member of HpeKmsConfig.v1_0_0.HpeKmsConfig
Description | Devices can take two types of action for encrypting namely, enable and disable. If user would like to modify the Passphrase, then User can opt to change encryption |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enable |
Enable Encryption for the device. |
Disable |
Disable Encryption for the device. |
Change |
Modify the Encryption Passphrase. |
Unlock |
Unlock the Encrypted device. |
Undefined |
Encryption action is Undefined. |
EncryptableDevices[{item}].EncryptionPhrase Member of HpeKmsConfig.v1_0_0.HpeKmsConfig
Description | Encryption Passphrase would show up if the device is encrypted and be modified as well. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
EncryptableDevices[{item}].EncryptionStatus Member of HpeKmsConfig.v1_0_0.HpeKmsConfig
Description | Encryption status of the device. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
EncryptionStatusUnknown |
Device is encrypted, but Passphrase is unknown. |
Encrypted |
Device is Encrypted. |
Decrypted |
Device is Unencrypted. |
EncryptableDevices[{item}].PassphraseType Member of HpeKmsConfig.v1_0_0.HpeKmsConfig
Description | Passphrase can be either entered manually or auto generated |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Auto |
Passphrase is generated from the system. |
Manual |
Passphrase is entered manually. |
KeyManagementType
Member of HpeKmsConfig.v1_0_0.HpeKmsConfig
Description | Key Management Type. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Key Management is Disabled |
Local |
Key Management Type is Local |
Remote |
Key Management Type is Remote |
OpalBlockSid
Member of HpeKmsConfig.v1_0_0.HpeKmsConfig
Description | TCG Block SID. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Disable TCG Block SID feature. |
Enabled |
Enable TCG Block SID feature. |
HpeMaintenanceWindow.v1_0_1.HpeMaintenanceWindow
@odata.type: "#HpeMaintenanceWindow.v1_0_1.HpeMaintenanceWindow"
The HpeMaintenanceWindow resource describes the properties for managing the time window for a software or firmware update task or install set.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/maintenancewindows/{item} |
GET POST PATCH DELETE |
Created
Member of HpeMaintenanceWindow.v1_0_1.HpeMaintenanceWindow
Description | ISO-time of maintenance window creation (by whomever created this thing) |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Expire
Member of HpeMaintenanceWindow.v1_0_1.HpeMaintenanceWindow
Description | ISO 8601 Redfish-style time string after which we will automatically change state to Expired - null for no expire time |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | date-time |
Modified
Member of HpeMaintenanceWindow.v1_0_1.HpeMaintenanceWindow
Description | ISO-time of last maintenance window item update by updater (not client) |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
StartAfter
Member of HpeMaintenanceWindow.v1_0_1.HpeMaintenanceWindow
Description | ISO 8601 Redfish-style time string of earliest execution. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | date-time |
HpeMaintenanceWindowCollection.HpeMaintenanceWindowCollection
@odata.type: "#HpeMaintenanceWindowCollection.HpeMaintenanceWindowCollection"
A Collection of HpeMaintenanceWindow resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/maintenancewindows |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeMaintenanceWindow |
Members (array)
Member of HpeMaintenanceWindowCollection.HpeMaintenanceWindowCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeMaintenanceWindowCollection.HpeMaintenanceWindowCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeMaintenanceWindowCollection.HpeMaintenanceWindowCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpePowerMeter.v2_0_1.HpePowerMeter
@odata.type: "#HpePowerMeter.v2_0_1.HpePowerMeter"
The HpePowerMeter resource contains the computer system power history logged by the BMC.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power/fastpowermeter |
GET |
/redfish/v1/chassis/{item}/power/powermeter |
GET |
Average
Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Average power across all samples, over the last 24 hours. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Maximum
Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Maximum power across all samples, taken from the 24 hour history. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Minimum
Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Minimum power across all samples, taken from the 24 hour history. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerDetail (array)
Member of HpePowerMeter.v2_0_1.HpePowerMeter
PowerDetail
is an array containing elements of:
PowerDetail[{item}].AmbTemp Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Ambient temperature, in degrees Celsius. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerDetail[{item}].Average Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Average power in Watts over the sample time. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerDetail[{item}].Cap Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | The applicable power cap in Watts at the time of this power sample. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerDetail[{item}].CpuAvgFreq Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | CPU average frequency in MHz. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerDetail[{item}].CpuCapLim Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Measures the effect of the power cap on performance in percent. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerDetail[{item}].CpuMax Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | The percentage of time the CPU spent in its maximum power mode. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerDetail[{item}].CpuPwrSavLim Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Measures the effect of CPU Power Regulator state switching on performance in percent. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerDetail[{item}].CpuUtil Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | CPU utilization in percent. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerDetail[{item}].CpuWatts Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | The power consumed by the system CPUs in Watts. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerDetail[{item}].DimmWatts Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | The power consumed by the system memory DIMMs in Watts. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerDetail[{item}].GpuWatts Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | The power consumed by the GPU(s) in Watts. This will be 0 if no GPUs are installed or if the drivers are not loaded. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerDetail[{item}].Minimum Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Minimum power in Watts over the sample time. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerDetail[{item}].Peak Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Peak power in Watts over the sample time. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerDetail[{item}].PrMode Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Power Regulator mode, which can be OS Control, Static High, Static Low or Dynamic. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
dyn |
Dynamic Mode - CPU power regulation is managed dynamically by the firmware. |
min |
Minimum Mode - CPU power regulation is configured to save as much power as possible at the possible expense of performance. |
max |
Maximum Mode - CPU power regulation is configured for maximum performance at the possible expense of power efficiency. |
osc |
OS Control Mode - CPU power regulation is managed by the Operating System. |
PowerDetail[{item}].PunCap Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | If true, CPU performance is being penalized by the current power cap. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
PowerDetail[{item}].Time Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Time at which the power sample detail was captured. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
PowerDetail[{item}].UnachCap Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | If true, the configured power cap could not be achieved due to system power requirements. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Samples
Member of HpePowerMeter.v2_0_1.HpePowerMeter
Description | Number of samples in the array. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeRemoteSupport.v2_6_0.HpeRemoteSupport
@odata.type: "#HpeRemoteSupport.v2_6_0.HpeRemoteSupport"
The HpeRemoteSupport resource describes the properties for management of HPE Embedded Report Support.
This resource type was added in iLO 5 1.20
HpeRemoteSupport enables management of HPE Remote Support configuration on iLO 5.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/remotesupportservice |
GET POST PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
ServiceEventLogs |
Collection of LogEntry |
ConnectModel
Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | The Remote Support connect model type. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
CentralConnect |
DestinationPort
Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | The port number of the Insight Remote Support server. This is applicable for Central Connect only. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
DestinationURL
Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | The host name or IP address of the Remote Support server. This is applicable for Central Connect only. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
ExternalAgentName
Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | This indicates the name of external Remote Support agent. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
HpePassportPassword
Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | HPE Passport Account Password. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
HpePassportUserId
Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | HPE Passport Account Id. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
LastTransmissionDate
Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | The last transmission date. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
LastTransmissionError
Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | The last transmission error. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
LastTransmissionType
Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | The last transmission type. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
ActiveHealthSystemData |
L2DataCollection |
Registration |
Deregistration |
ServiceEvent |
NoTransmission |
Null |
MaintenanceModeEnabled
Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | This indicates if the server is in Maintenance Mode or not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
MaintenanceTimeLeftInMinutes
Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | This indicates the time remaining in minutes for the server to be in the maintenance mode. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
ProxySettings
ProxySettings.Password Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | Password for web proxy server authentication. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
ProxySettings.Port Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | Port number on which to communicate with the web proxy server. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
ProxySettings.Url Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | Web proxy server host name or IP address. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | url |
ProxySettings.Username Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | Username for web proxy server authentication. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
RemoteSupportEnabled
Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Description | This indicates if the Remote Support Service is available or not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
ServiceEventLogs
A reference to the collection of service event logs.
ServiceEventLogs is a link ("@odata.id": URI
) to another resource.
Actions
HpeRemoteSupport.RegisterDeviceToRemoteSupport Member of HpeRemoteSupport.v2_6_0.HpeRemoteSupport
Parameters:
DestinationUrl (string)
The host name or IP address of the Remote Support server. This is applicable for Central Connect only.
HpeSecureEraseReport.v1_1_0.HpeSecureEraseReport
@odata.type: "#HpeSecureEraseReport.v1_1_0.HpeSecureEraseReport"
The HpeSecureEraseReport resource describes the secure erase status and the other details of the devices during the secure system erase operation.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/secureerasereportservice/secureerasereportentries/{item} |
GET |
DeviceIdentifier
Member of HpeSecureEraseReport.v1_1_0.HpeSecureEraseReport
Description | This represents the unique identifier for the device in the system like it’s physical location or the exact device path etc., |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
DeviceType
Member of HpeSecureEraseReport.v1_1_0.HpeSecureEraseReport
Description | This indicates the device type being securely erased. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
SATADrives |
This indicates the device type is SATA drive |
NVMeDrives |
This indicates the device type is NVMe drive |
NVDIMM |
This indicates the device type is NVDIMM/Persistent Memory |
TPM |
This indicates the device type is TPM (Trusted Platform Module) |
UEFIStore |
This indicates the device type is UEFI Store |
NAND |
This indicates the device type is Embedded NAND Flash |
NVRAM |
This indicates the device type is NVRAM (Battery backed SRAM) |
PCIControllers |
This indicates the device type is PCI Controllers |
EraseEndTime
Member of HpeSecureEraseReport.v1_1_0.HpeSecureEraseReport
Description | The date and time of the end of secure erase operation, ISO8601 Redfish-style time |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
EraseStartTime
Member of HpeSecureEraseReport.v1_1_0.HpeSecureEraseReport
Description | The date and time of the start of secure erase operation, ISO8601 Redfish-style time |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
EraseStatus
Member of HpeSecureEraseReport.v1_1_0.HpeSecureEraseReport
Description | Indicates the secure erase status of the individual components |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Idle |
Indicates Secure System Erase is not started |
Initiated |
Indicates Secure System Erase process is started |
InProgress |
Indicates Secure System Erase process is under progress |
CompletedWithSuccess |
Indicates Secure System Erase process has been completed with no errors |
CompletedWithErrors |
Indicates Secure System Erase process has been completed with some errors |
Failed |
Indicates Secure System Erase process has failed |
EraseType
Member of HpeSecureEraseReport.v1_1_0.HpeSecureEraseReport
Description | This indicates the NIST SP800-88 Rev.1 (National Institute of Standards and Technology) approved techniques to sanitize a particular media or device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Purge |
This indicates that Purge technique is used to sanitize the device. |
Clear |
This indicates that Clear technique is used to sanitize the device. |
SerialNumber
Member of HpeSecureEraseReport.v1_1_0.HpeSecureEraseReport
Description | This represents the serial number of the device being erased. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
HpeSecureEraseReportCollection.HpeSecureEraseReportCollection
@odata.type: "#HpeSecureEraseReportCollection.HpeSecureEraseReportCollection"
A Collection of HpeSecureEraseReport resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/secureerasereportservice/secureerasereportentries |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeSecureEraseReport |
Members (array)
Member of HpeSecureEraseReportCollection.HpeSecureEraseReportCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeSecureEraseReportCollection.HpeSecureEraseReportCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeSecureEraseReportCollection.HpeSecureEraseReportCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeSecureEraseReportService.v1_0_0.HpeSecureEraseReportService
@odata.type: "#HpeSecureEraseReportService.v1_0_0.HpeSecureEraseReportService"
The HpeSecureEraseReportService resource describes the properties of the Secure Erase Report feature.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/secureerasereportservice |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Links/SecureEraseReportEntries |
Collection of HpeSecureEraseReport |
EraseInitiatedBy
Member of HpeSecureEraseReportService.v1_0_0.HpeSecureEraseReportService
Description | This indicates the user name who initiated the secure system erase process. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ServerSerialNumber
Member of HpeSecureEraseReportService.v1_0_0.HpeSecureEraseReportService
Description | This represents the server serial number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Actions
HpeSecureEraseReportService.DeleteSecureEraseReport Member of HpeSecureEraseReportService.v1_0_0.HpeSecureEraseReportService There are no parameters for this action.
HpeSecurityService.v2_4_0.HpeSecurityService
@odata.type: "#HpeSecurityService.v2_4_0.HpeSecurityService"
The HpeSecurityService resource describes the properties for management of the security configuration of the BMC.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/securityservice |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Links/SSO |
HpeiLOSSO |
Links/SecurityParams |
Collection of HpeiLOSecurityParam |
Links/AutomaticCertificateEnrollment |
HpeAutomaticCertEnrollment |
Links/HttpsCert |
HpeHttpsCert |
Links/CertAuth |
HpeCertAuth |
Links/ESKM |
HpeESKM |
Links/SecurityDashboard |
HpeiLOSecurityDashboard |
ComponentIntegrityPolicy
Member of HpeSecurityService.v2_4_0.HpeSecurityService
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
NoPolicy |
HaltBootOnSPDMFailure |
CurrentCipher
Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | Current cipher in use. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
GlobalComponentIntegrity
Member of HpeSecurityService.v2_4_0.HpeSecurityService
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Enabled |
Disabled |
LoginSecurityBanner
LoginSecurityBanner.IsEnabled Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | Login security banner is enabled or not. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
LoginSecurityBanner.SecurityMessage Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | Text message to appear on the iLO login page and iLO SSH pre-authentication banner when login security banner is enabled. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
OpenBMCTransferOfOwnership
Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | State of iLO-OpenBMC Transfer of Ownership feature. |
Type | string or null |
Read Only | True |
Added | iLO6 1.35 |
The following are the supported values:
Value | Description |
---|---|
Supported |
OpenBMC Transfer feature is supported but it is not enabled for transfer. |
Inhibited |
OpenBMC Transfer feature is inhibited for this server. |
Configured |
iLO is configured successfully for OpenBMC transfer. |
UnSupportedSecurityState |
OpenBMC Transfer feature is not supported in FIPS/CNSA security states. |
UnSupportedSecureElement |
OpenBMC Transfer feature is not supported without correct Secure Element. |
Error |
Error state. |
OpenBMCTransferStatus
Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | OpenBMC transfer status. |
Type | string or null |
Read Only | True |
Added | iLO6 1.35 |
The following are the supported values:
Value | Description |
---|---|
NotPerformed |
OpenBMC Transfer is not performed |
Performed |
OpenBMC Transfer is performed at least once |
Unknown |
Status unknown |
PlatformCert
PlatformCert.Certificates
This is a reference to a collection of certificates used for PlatformCert by this manager.
Certificates is a link ("@odata.id": URI
) to another resource.
PlatformCertUpdate
PlatformCertUpdate.Certificates
This is a reference to a collection of certificates used for PlatformCert Updates by this manager.
Certificates is a link ("@odata.id": URI
) to another resource.
SSHHostKey
Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | SSH Host Key identifying the service. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
SecurityState
Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | The operational security level of this Manager. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Wipe |
Manager is currently wiping security related content and returning to a lower security mode. This state will transition automatically when finished. |
Production |
Manager is operating in a normal security mode. Default state for new systems. |
HighSecurity |
Manager is operating in high security mode, requiring extra authentication on host interface(s), and stronger encryption on network interfaces. |
FIPS |
Similar to High Security. This mode is intended to meet the FIPS 140-2 level 1 and Common Criteria security requirements. A reset to defaults is required to exit this mode. |
CNSA |
Same as FIPS. Additionally meets the criteria for NSA Commercial National Security Algorithm suite. Must be in FIPS mode to transition to CNSA. |
SuiteB |
Same as FIPS. Additionally meets the criteria for NSA SuiteB Top Secret installations. Must be in FIPS mode to transition to SuiteB. |
SynergySecurityMode |
Synergy Security Mode is the mode supported by the Synergy Composer. |
SecurityState@Redfish.AllowableValues (array)
Member of HpeSecurityService.v2_4_0.HpeSecurityService
SecurityState@Redfish.AllowableValues
is an array containing elements of:
SecurityState@Redfish.AllowableValues[{item}] Member of HpeSecurityService.v2_4_0.HpeSecurityService
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Wipe |
Production |
HighSecurity |
FIPS |
CNSA |
SuiteB |
SystemIAK
SystemIAK.Certificates
This is a reference to a collection of certificates used for System IAK by this manager.
Certificates is a link ("@odata.id": URI
) to another resource.
SystemIDevID
SystemIDevID.Certificates
This is a reference to a collection of certificates used for System IDevId by this manager.
Certificates is a link ("@odata.id": URI
) to another resource.
TLSVersion
TLSVersion.TLS1_0 Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | This Indicate whether the TLS 1.0 is Enabled or disabled. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Enabled TLS 1.0. |
Disabled |
Disabled TLS 1.0. |
TLSVersion.TLS1_1 Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | This Indicate whether the TLS 1.1 is Enabled or disabled. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Enabled TLS 1.1. |
Disabled |
Disabled TLS 1.1. |
TLSVersion.TLS1_2 Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | This Indicate whether the TLS 1.2 is Enabled or disabled. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Enabled TLS 1.2. |
Disabled |
Disabled TLS 1.2. |
TLSVersion.TLS1_3 Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | This Indicate whether the TLS 1.3 is Enabled or disabled. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Enabled TLS 1.3. |
Disabled |
Disabled TLS 1.3. |
TrustedOSSecurity
TrustedOSSecurity.EnableBackgroundScan Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | Enables or disables background scan of host OS software. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
TrustedOSSecurity.LastScanResult Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | Health of the host after the last scan done by Trusted OS Security scan engine. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
OK |
The last Trusted OS Security scan completed without finding any issues. |
Critical |
The last Trusted OS Security scan completed finding issue(s). Refer to the SL log for details. |
Unknown |
The health is Unknown because either the scan data is unavailable or scan is not enabled or last scan failed to complete. |
TrustedOSSecurity.LastScanTime Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | The time stamp of the last Trusted OS Security scan. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
TrustedOSSecurity.OnIntegrityFailure Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | Sets the policy for how the Trusted OS Security check handles integrity failures. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NoAction |
No action will be taken when a failure is detected. |
Alert |
Generate an alert when a failure is detected. |
PowerOff |
Gracefully power system off when a failure is detected. |
PowerOffForce |
Force system power off when a failure is detected. |
Reset |
Reset system power off when a failure is detected. |
ColdBoot |
ColdBoot system power off when a failure is detected. |
ForceNMI |
ForceNMI system power off when a failure is detected. |
TrustedOSSecurity.ScanEverySeconds Member of HpeSecurityService.v2_4_0.HpeSecurityService
Description | Sets the interval between Trusted OS Security scans in second increments. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
iLOIDevID
iLOIDevID.Certificates
This is a reference to a collection of certificates used for iLO IDevId by this manager.
Certificates is a link ("@odata.id": URI
) to another resource.
iLOLDevID
iLOLDevID.Certificates
This is a reference to a collection of certificates used for iLO LDevId by this manager.
Certificates is a link ("@odata.id": URI
) to another resource.
HpeServerAccHddService.v1_0_0.HpeServerAccHddService
@odata.type: "#HpeServerAccHddService.v1_0_0.HpeServerAccHddService"
The HpeServerAccHddService resource describes the properties for management of shared power in an enclosure.
This resource type was added in iLO 5 1.20 and is available on HPE ProLiant Apollo XL systems.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/acchddservice |
GET |
BackplaneInfo
BackplaneInfo.EndBay Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Represents a ending number of the bay. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BackplaneInfo.FirmwareRevision Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Indicates the firmware revision in ASCII value. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
BackplaneInfo.HostPortsInfo (array)
Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
HostPortsInfo
is an array containing elements of:
HostPortsInfo[{item}].NodeNumber Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Represents the node number of compute node attached to host port x in SEP. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HostPortsInfo[{item}].PortNumber Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Represents the number of physical host ports in SEP. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HostPortsInfo[{item}].SlotNumber Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Represents the slot number of SAS attached to host port x in SEP. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BackplaneInfo.SEPID Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Indicates the storage enclosure processor ID. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BackplaneInfo.SEPNodeId Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | The node ID represent the node ID where the storage enclosure processor is residing. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BackplaneInfo.StartBay Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Represents a starting number of the bay. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BackplaneInfo.TotalBays Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Total bay count represents the number of bays attached to the SEP. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BackplaneInfo.TypeID Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Indicates the Backplane type ID for the identifier for backplane type. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BackplaneInfo.WWID Member of HpeServerAccHddService.v1_0_0.HpeServerAccHddService
Description | Represents a unique world wide ID defining a SEP. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
@odata.type: "#HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone"
The HpeServerAccHddZone resource describes the properties for management of shared hard drives in an enclosure.
This resource type was added in iLO 5 1.20 and is available on HPE ProLiant Apollo XL systems.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/acchddservice/zone |
GET POST |
BackupZoneConfigurationInBmc
BackupZoneConfigurationInBmc.HostPort (array)
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
HostPort
is an array containing elements of:
HostPort[{item}].BayNumber (array)
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
BayNumber
is an array containing elements of:
BayNumber[{item}] Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HostPort[{item}].PortNumber Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
Description | Represents the number of physical host ports in SEP, null represents unassigned bay group. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
CurrentZoneConfiguration
CurrentZoneConfiguration.HostPort (array)
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
HostPort
is an array containing elements of:
HostPort[{item}].BayNumber (array)
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
BayNumber
is an array containing elements of:
BayNumber[{item}] Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HostPort[{item}].PortNumber Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
Description | Represents the number of physical host ports in SEP, null represents unassigned bay group. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PendingZoneConfiguration
PendingZoneConfiguration.HostPort (array)
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
HostPort
is an array containing elements of:
HostPort[{item}].BayNumber (array)
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
BayNumber
is an array containing elements of:
BayNumber[{item}] Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HostPort[{item}].PortNumber Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
Description | Represents the number of physical host ports in SEP, null represents unassigned bay group. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
SEPNodeId
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
Description | The node ID represent the node ID where the storage enclosure processor is residing. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
TypeID
Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone
Description | Indicates the Backplane type ID for the identifier for backplane type. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Actions
HpeServerAccHddZone.BackupConfigurationToBmc Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone Backup Apollo Chassis Controller Hdd zone configuration to BMC.
There are no parameters for this action.
HpeServerAccHddZone.LoadDefault Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone Load Apollo Chassis Controller default Hdd zone configuration.
There are no parameters for this action.
HpeServerAccHddZone.ConfigureZone Member of HpeServerAccHddZone.v1_0_0.HpeServerAccHddZone Execute Apollo Chassis Controller Hdd zone configuration.
Parameters:
HostPort (array)
HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
@odata.type: "#HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration"
The HpeServerAccPowerCalibration resource describes the properties for management of shared power in an enclosure.
This resource type was added in iLO 5 1.20 and is available on HPE ProLiant Apollo XL systems.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power/accpowerservice/calibration |
GET POST |
CalibrationData
CalibrationData.EndTime Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The calibration end time stamp. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.StartTime Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The calibration start time stamp. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.State Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | Specifies whether the calibration is valid or not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower CalibrationData.ThrottlePeakPower.Percent_000 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 0 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_005 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 5 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_010 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 10 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_015 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 15 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_020 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 20 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_025 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 25 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_030 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 30 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_035 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 35 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_040 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 40 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_045 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 45 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_050 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 50 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_055 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 55 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_060 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 60 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_065 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 65 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_070 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 70 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_075 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 75 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_080 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 80 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_085 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 85 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_090 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 90 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_095 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 95 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ThrottlePeakPower.Percent_100 Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The peak power of 100 Percent throttling. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationData.ZoneNumber Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The zone number either on the entire chassis or specific zone. 0 for entire chassis, other number is for specific zone. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CalibrationInProgress
Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration
Description | The current state of the chassis power zone calibration task. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Actions
HpeServerAccPowerCalibration.Calibrate Member of HpeServerAccPowerCalibration.v1_0_0.HpeServerAccPowerCalibration Execute the Apollo Chassis Controller power calibration configuration.
Parameters:
EEPROMSaveEnabled (boolean)
AllZone (boolean)
Seconds (integer)
ZoneNumber (integer)
ActionType (string)
Value | Description |
---|---|
Start | |
Stop |
HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
@odata.type: "#HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit"
The HpeServerAccPowerLimit resource describes the properties for management of shared power in an enclosure.
This resource type was added in iLO 5 1.20 and is available on HPE ProLiant Apollo XL systems.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power/accpowerservice/powerlimit |
GET POST |
ActualPowerLimits (array)
Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
ActualPowerLimits
is an array containing elements of:
ActualPowerLimits[{item}].PowerLimitInWatts Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
Description | The actual power limit (in watts) for the zone, it will be set to null when power limit disabled. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
ActualPowerLimits[{item}].ZoneNumber Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
Description | The zone number either on the entire chassis or specific zone. 0 for entire chassis, other number is for specific zone. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerLimitRanges (array)
Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
PowerLimitRanges
is an array containing elements of:
PowerLimitRanges[{item}].MaximumPowerLimit Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
Description | The Maximum power limit (in watts) for the zone. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerLimitRanges[{item}].MinimumPowerLimit Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
Description | The Minimum power limit (in watts) for the zone. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerLimitRanges[{item}].ZoneNumber Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
Description | The zone number either on the entire chassis or specific zone. 0 for entire chassis, other number is for specific zone. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerLimits (array)
Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
PowerLimits
is an array containing elements of:
PowerLimits[{item}].PowerLimitInWatts Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
Description | The target power limit (in watts) for the zone, it will be set to null when power limit disabled. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
PowerLimits[{item}].ZoneNumber Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit
Description | The zone number either on the entire chassis or specific zone. 0 for entire chassis, other number is for specific zone. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Actions
HpeServerAccPowerLimit.ConfigurePowerLimit Member of HpeServerAccPowerLimit.v1_0_0.HpeServerAccPowerLimit Deploy the Apollo Chassis Controller power limit configuration.
Parameters:
PowerLimits (array)
HpeServerAccPowerNodesInfo.v1_0_0.HpeServerAccPowerNodesInfo
@odata.type: "#HpeServerAccPowerNodesInfo.v1_0_0.HpeServerAccPowerNodesInfo"
The HpeServerAccPowerNodesInfo resource describes the properties for management of shared power in an enclosure.
This resource type was added in iLO 5 1.20 and is available on HPE ProLiant Apollo XL systems.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power/accpowerservice/nodesinfo |
GET |
MaxSupportedNodes
Member of HpeServerAccPowerNodesInfo.v1_0_0.HpeServerAccPowerNodesInfo
Description | Total Nodes supported in Chassis. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
NodeInfoList (array)
Member of HpeServerAccPowerNodesInfo.v1_0_0.HpeServerAccPowerNodesInfo
NodeInfoList
is an array containing elements of:
NodeInfoList[{item}].NodeNumber Member of HpeServerAccPowerNodesInfo.v1_0_0.HpeServerAccPowerNodesInfo
Description | The physical node number in chassis. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
NodeInfoList[{item}].Throttle Member of HpeServerAccPowerNodesInfo.v1_0_0.HpeServerAccPowerNodesInfo
Description | It indicates the current throttle on the node. (PWM %) |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
NodeInfoList[{item}].WarningStatus Member of HpeServerAccPowerNodesInfo.v1_0_0.HpeServerAccPowerNodesInfo
Description | Specifies whether the node is in warning status or not. WarningStatus indicates a node is over loading and chassis manager force it throttle at 50% for 5 mins |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
HpeServerAccPowerService.v1_0_0.HpeServerAccPowerService
@odata.type: "#HpeServerAccPowerService.v1_0_0.HpeServerAccPowerService"
The HpeServerAccPowerService resource describes the properties for management of shared power in an enclosure.
This resource type was added in iLO 5 1.20 and is available on HPE ProLiant Apollo XL systems.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power/accpowerservice |
GET PATCH |
EEPROMSaveEnabled
Member of HpeServerAccPowerService.v1_0_0.HpeServerAccPowerService
Description | Determines whether the EEPROM save is enabled or disabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
PowerRegulationEnabled
Member of HpeServerAccPowerService.v1_0_0.HpeServerAccPowerService
Description | Determines whether power regulation is enabled or disabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
PowerRegulatorMode
Member of HpeServerAccPowerService.v1_0_0.HpeServerAccPowerService
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ACRedundancy |
AC Redundancy with Throttling Mode (Max Performance w/ Redundancy). |
UserConfig |
User Configurable Mode. |
APM |
APM Power Regulator Mode. Cannot configure by iLO. |
PowerFeedProtect |
Power Feed Protection Mode. |
HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone
@odata.type: "#HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone"
The HpeServerAccPowerZone resource describes the properties for management of shared power in an enclosure.
This resource type was added in iLO 5 1.20 and is available on HPE ProLiant Apollo XL systems.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power/accpowerservice/zone |
GET POST |
ZoneConfiguration
ZoneConfiguration.Zone (array)
Member of HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone
Zone
is an array containing elements of:
Zone[{item}].Node (array)
Member of HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone
Node
is an array containing elements of:
Node[{item}].NodeNumber Member of HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone
Description | The node number of zone configuration. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Node[{item}].NodePriority Member of HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone
Description | The power regulation node priority, the range must between 1 - 5. 5 is default and lowest priority. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Zone[{item}].ZoneNumber Member of HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone
Description | The zone number of zone configuration. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Zone[{item}].ZonePriority Member of HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone
Description | The power regulation zone priority, the range must between 1 - 5. 5 is default and lowest priority. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Actions
HpeServerAccPowerZone.ConfigureZone Member of HpeServerAccPowerZone.v1_0_0.HpeServerAccPowerZone Execute the Apollo Chassis Controller power regulation zone configuration.
Parameters:
Zone (array)
HpeServerBootSettings.v2_0_0.HpeServerBootSettings
@odata.type: "#HpeServerBootSettings.v2_0_0.HpeServerBootSettings"
The schema definition of the server UEFI Boot Order resource.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bios/boot |
GET |
/redfish/v1/systems/{item}/bios/boot/settings |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
@Redfish.Settings/SettingsObject |
HpeServerBootSettings |
Oem/Hpe/Links/BaseConfigs |
HpeBaseConfigs |
@Redfish.Settings
Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings See the Redfish standard schema and specification for information on common @Redfish properties.
BootSources (array)
Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
BootSources
is an array containing elements of:
BootSources[{item}].BootString Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | User-readable string that describes the UEFI boot option. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
BootSources[{item}].CorrelatableID Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | Contains any CorrelatableIDs that represent this boot option. The correlatableID values can be JSON Pointers or UEFI identifiers. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
BootSources[{item}].StructuredBootString Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | Uniquely identifies this boot option within the server. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
BootSources[{item}].UEFIDevicePath Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | Standardized text representation of the UEFI device path for this boot option, in UTF-8 format. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
DefaultBootOrder (array)
Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
DefaultBootOrder
is an array containing elements of:
DefaultBootOrder[{item}] Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | Default UEFI boot order device type. This is used to define the order in which UEFI boot order is reset to when a default configuration is requested. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
UefiShell |
Floppy |
Cd |
Usb |
EmbeddedStorage |
PcieSlotStorage |
EmbeddedFlexLOM |
PcieSlotNic |
DesiredBootDevices (array)
Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
DesiredBootDevices
is an array containing elements of:
DesiredBootDevices[{item}].CorrelatableID Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | Standardized text representation of the UEFI device path of the desired boot device, in UTF-8 format. For example ‘PciRoot(0x0)/Pci(0x2,0x2)/Pci(0x0,0x0)’ |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
DesiredBootDevices[{item}].Lun Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | The Logical Unit Number (LUN) of the desired boot device. This value must be a hexadecimal string with an even number of 2 to 16 characters, excluding the first two characters, 0x (for example, ‘0x01’). |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
DesiredBootDevices[{item}].Wwn Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | The Fibre Channel World Wide Name (WWN) of the desired boot device. This value must be a hexadecimal string with an even number of 2 to 16 characters, excluding the first two characters, 0x (for example, ‘0x0001020304050607’). |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
DesiredBootDevices[{item}].iScsiTargetName Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | The iSCSI node target name of the desired boot device. The value must be a string based on IETF RFC 3270, and can be up to 223 characters in length (for example, ‘iqn.1991-05.com.microsoft:iscsitarget-iscsidisk-target’). |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
PersistentBootConfigOrder (array)
Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
PersistentBootConfigOrder
is an array containing elements of:
PersistentBootConfigOrder[{item}] Member of HpeServerBootSettings.v2_0_0.HpeServerBootSettings
Description | The structured boot string that references a corresponding entry in the BootSources array. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
HpeServerConfigLock.v1_0_0.HpeServerConfigLock
@odata.type: "#HpeServerConfigLock.v1_0_0.HpeServerConfigLock"
The schema definition for Server Configuration Lock configuration.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/Systems/{item}/Bios/Serverconfiglock/Settings |
GET PATCH |
/redfish/v1/systems/{item}/bios/Serverconfiglock |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
@Redfish.Settings/SettingsObject |
HpeServerConfigLock |
Oem/Hpe/Links/BaseConfigs |
HpeBaseConfigs |
@Redfish.Settings
Member of HpeServerConfigLock.v1_0_0.HpeServerConfigLock See the Redfish standard schema and specification for information on common @Redfish properties.
NewServerConfigLockPassword
Member of HpeServerConfigLock.v1_0_0.HpeServerConfigLock
Description | The new Server Configuration Lock password. This field is used to update the current Server Configuration Lock password and force the system configuration digital fingerprint to be recalculated. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ServerConfigLockChallenge
Member of HpeServerConfigLock.v1_0_0.HpeServerConfigLock
Description | Select this option to enable or disable a Server Configuration Lock password challenge on every boot. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Disable Server Configuration Lock password challenge on every boot. |
Enabled |
Enable Server Configuration Lock password challenge on every boot. |
Null |
A value is temporarily unavailable |
ServerConfigLockDisable
Member of HpeServerConfigLock.v1_0_0.HpeServerConfigLock
Description | Select this option to disable Server Configuration Lock. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
False |
Don’t disable Server Configuration Lock. |
True |
Disable Server Configuration Lock. |
Null |
A value is temporarily unavailable |
ServerConfigLockExcludeCpus
Member of HpeServerConfigLock.v1_0_0.HpeServerConfigLock
Description | Select this option to exclude CPU information from the Digital Fingerprint. Note that this setting only takes effect when Server Configuration Lock is enabled/reenabled. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
False |
Do not exclude CPU information from the Digital Fingerprint. |
True |
Exclude CPU information from the Digital Fingerprint. |
Null |
A value is temporarily unavailable |
ServerConfigLockExcludeDimms
Member of HpeServerConfigLock.v1_0_0.HpeServerConfigLock
Description | Select this option to exclude DIMM information from the Digital Fingerprint. Note that this setting only takes effect when Server Configuration Lock is enabled/reenabled. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
False |
Do not exclude DIMM information from the Digital Fingerprint. |
True |
Exclude DIMM information from the Digital Fingerprint. |
Null |
A value is temporarily unavailable |
ServerConfigLockExcludeFwRevs
Member of HpeServerConfigLock.v1_0_0.HpeServerConfigLock
Description | Select this option to exclude system firmware revisions from the Digital Fingerprint. Note that this setting only takes effect when Server Configuration Lock is enabled/reenabled. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
False |
Do not exclude system firmware revision information from the Digital Fingerprint. |
True |
Exclude system firmware revision information from the Digital Fingerprint. |
Null |
A value is temporarily unavailable |
ServerConfigLockExcludePciSlots
Member of HpeServerConfigLock.v1_0_0.HpeServerConfigLock
Description | Select this option to exclude PCIe slot information from the Digital Fingerprint. Note that this setting only takes effect when Server Configuration Lock is enabled/reenabled. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
False |
Do not exclude PCIe slot information from the Digital Fingerprint. |
True |
Exclude PCIe slot information from the Digital Fingerprint. |
Null |
A value is temporarily unavailable |
ServerConfigLockExcludeSecurity
Member of HpeServerConfigLock.v1_0_0.HpeServerConfigLock
Description | Select this option to exclude security configuration information from the Digital Fingerprint. Note that this setting only takes effect when Server Configuration Lock is enabled/reenabled. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
False |
Do not exclude security configuration information from the Digital Fingerprint. |
True |
Exclude security configuration information from the Digital Fingerprint. |
Null |
A value is temporarily unavailable |
ServerConfigLockLogStored
Member of HpeServerConfigLock.v1_0_0.HpeServerConfigLock
Description | Has a Server Configuration Lock failure log been stored? |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
True |
A Server Configuration Lock failure has been logged. |
False |
A Server Configuration Lock failure has not been logged. |
ServerConfigLockPassword
Member of HpeServerConfigLock.v1_0_0.HpeServerConfigLock
Description | The Server Configuration Lock password. If Server Configuration Lock is currently enabled, this field is used to convey the current Server Configuration Lock password and is required to make any Server Configuration Lock configuration changes. If Server Configuration Lock is currently disabled, this field is used to set the Server Configuration Lock password, and to digitally fingerprint the system to enable Server Configuration Lock. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ServerConfigLockState
Member of HpeServerConfigLock.v1_0_0.HpeServerConfigLock
Description | Enabled/Disabled state of the Server Configuration Lock Feature. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Disabled |
The Server Configuration Lock feature is disabled. |
Enabled |
The Server Configuration Lock feature is enabled. |
ServerConfigLockTamperHalt
Member of HpeServerConfigLock.v1_0_0.HpeServerConfigLock
Description | Select this option to enable or disable the Server Configuration Lock behavior to halt on a configuration change detection. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Disable Server Configuration Lock behavior to halt on configuration changes. |
Enabled |
Enable Server Configuration Lock behavior to halt on configuration changes. |
Null |
A value is temporarily unavailable |
ServerConfigLockTransport
Member of HpeServerConfigLock.v1_0_0.HpeServerConfigLock
Description | Select this option to enable or disable Server Configuration Lock “first-boot” behaviors. This option is expected to be enabled just prior to shipping the server. When the server arrives at its destination and is first powered on, Server Configuration Lock will require the Server Configuration Lock password in order to boot. Server Configuration Lock will also indicate if someone attempted to change the system configuration during the shipment process. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Disable Server Configuration Lock “first-boot” behaviors. |
Enabled |
Enable Server Configuration Lock “first-boot” behaviors. |
Null |
A value is temporarily unavailable |
ServerConfigLockTransportAudit
Member of HpeServerConfigLock.v1_0_0.HpeServerConfigLock
Description | Select this option to enable or disable out-of-band acknowledge of Server Configuration Lock “first-boot” behaviors (see ServerConfigLockTransport). |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Disable Server Configuration Lock out-of-band acknowledge of “first-boot” audit. |
Enabled |
Enable Server Configuration Lock out-of-band acknowledge of “first-boot” audit. |
Null |
A value is temporarily unavailable |
HpeServerDevice.v2_1_0.HpeServerDevice
@odata.type: "#HpeServerDevice.v2_1_0.HpeServerDevice"
The HpeServerDevice resource describes the properties of FRU devices.
This resource type was added in iLO 5 1.20
HpeServerDevice represents physical server devices including part information. This is especially useful for system inventory.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/devices/{item} |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
DeviceInstances[] |
HpeServerPciDevice |
ComponentIntegrityStatus
Member of HpeServerDevice.v2_1_0.HpeServerDevice
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Unsupported |
Unsuccessful verification. |
Success |
Successful verification. |
Failure |
DeviceInstances (array)
Member of HpeServerDevice.v2_1_0.HpeServerDevice
DeviceInstances
is an array containing elements of:
DeviceInstances[{item}].@odata.id Member of HpeServerDevice.v2_1_0.HpeServerDevice
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
DeviceType
Member of HpeServerDevice.v2_1_0.HpeServerDevice
Description | Device type. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
GPU |
GPU |
PLX Controller |
PLX Controller (Bridge) |
Expansion Riser |
Expansion Riser |
Smart Storage |
Smart Storage |
SAS/SATA Storage Controller |
SAS/SATA Storage Controller |
IDE Storage Controller |
IDE Storage Controller |
USB Storage Controller |
USB Storage Controller |
Storage Controller |
Storage Controller |
LOM/NIC |
LOM/NIC |
Converged Network Adapter |
Converged Network Adapter |
Fibre Channel |
Fibre Channel |
Direct Attached NVMe Device |
Direct Attached NVMe Device |
Backplane PIC |
Backplane PIC |
Smart Storage Battery |
Smart Storage Battery |
USB |
Universal Serial Bus |
TPM |
Trusted Platform Module |
Communication Controller |
Communication Controller |
Unknown |
Unknown Device Type |
Embedded SATA Controller |
Embedded SATA Controller |
FirmwareVersion
FirmwareVersion.Current FirmwareVersion.Current.VersionString Member of HpeServerDevice.v2_1_0.HpeServerDevice
Description | This string represents the version of the firmware image. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
FirmwareVersion.FirmwareVersions (array)
Member of HpeServerDevice.v2_1_0.HpeServerDevice
FirmwareVersions
is an array containing elements of:
FirmwareVersions[{item}].ComponentName Member of HpeServerDevice.v2_1_0.HpeServerDevice
Description | Name of GPU cores |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
FirmwareVersions[{item}].VersionString Member of HpeServerDevice.v2_1_0.HpeServerDevice
Description | Version String of GPU cores |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Location
Member of HpeServerDevice.v2_1_0.HpeServerDevice
Description | Location of the device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MCTPProtocolDisabled
Member of HpeServerDevice.v2_1_0.HpeServerDevice
Description | Set to true to disable MCTP on this slot. Once disabled, can be enabled only through MCTP factory reset. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Manufacturer
Member of HpeServerDevice.v2_1_0.HpeServerDevice
Description | Device manufacturer. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PartNumber
Member of HpeServerDevice.v2_1_0.HpeServerDevice
Description | Board part Number which is HPE PCA Assembly Number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProductPartNumber
Member of HpeServerDevice.v2_1_0.HpeServerDevice
Description | Product Part Number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProductVersion
Member of HpeServerDevice.v2_1_0.HpeServerDevice
Description | Product Version. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SerialNumber
Member of HpeServerDevice.v2_1_0.HpeServerDevice
Description | Product Serial Number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of HpeServerDevice.v2_1_0.HpeServerDevice See the Redfish standard schema and specification for information on common Status object.
HpeServerDeviceCollection.HpeServerDeviceCollection
@odata.type: "#HpeServerDeviceCollection.HpeServerDeviceCollection"
A Collection of HpeServerDevice resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/devices |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeServerDevice |
Members (array)
Member of HpeServerDeviceCollection.HpeServerDeviceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeServerDeviceCollection.HpeServerDeviceCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeServerDeviceCollection.HpeServerDeviceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeServerPciDevice.v2_1_0.HpeServerPciDevice
@odata.type: "#HpeServerPciDevice.v2_1_0.HpeServerPciDevice"
The HpeServerPciDevice resource describes the properties of PCI devices.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/pcidevices/{item} |
GET |
BayNumber
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | Bay number value. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Bifurcated
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | Indicates if the PCIe device support bifurcation. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
BifurcationNotSupported |
This device does not support Bifurcation. |
BifurcationSupportedPrimaryDevice |
This device does support Bifurcation. |
BifurcationSupportedSecondaryDevice |
This is second bifurcated device. |
BifurcatedSecondaryDeviceLink
The link to the next bifurcated devices.
BifurcatedSecondaryDeviceLink is a link ("@odata.id": URI
) to another resource.
BusNumber
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | PCI device bus number value. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
ClassCode
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | PCI class code of the endpoint. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
DeviceID
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | PCI device ID of the device. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
DeviceInstance
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | PCI device instance value. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
DeviceLocation
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | PCI device location. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
DeviceNumber
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | PCI device number value. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
DeviceResourceId
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | PCI device resource id or hash id. |
Type | string |
Read Only | True |
Added | iLO6 1.20 |
DeviceSubInstance
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | PCI device sub-instance value. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
DeviceType
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | Device type value. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Flexible LOM |
Flexible LAN-On-Motherboard |
Embedded LOM |
Embedded LAN-On-Motherboard |
NIC |
Network Interface Controller |
HDD Not attached to a SA Controller |
Hard Disk Drive |
HDD Attached to a SA Controller |
Hard Disk Drive attached to an array controller |
Other PCI Device |
Other PCI Device |
Unknown |
Unknown PCI Device |
Other |
Other PCI Device |
Video |
Video Controller |
SCSI Controller |
SCSI Controller |
Ethernet |
Ethernet Controller |
Token Ring |
Token Ring Controller |
Sound |
Sound Controller |
PATA Controller |
Parallel ATA Controller |
SATA Controller |
Serial ATA Controller |
SAS Controller |
Serial Attached SCSI Controller |
Storage Controller |
Storage Controller (not Smart Array) |
Storage Array Controller |
Smart Array Storage Controller |
USB Hard Disk Drive |
USB Hard Disk Drive |
Firmware Volume |
Firmware Volume |
UEFI Shell |
UEFI Shell |
Generic UEFI USB Boot Entry |
Generic UEFI USB Boot Entry |
Dynamic Storage Array Controller |
Dynamic Smart Array Controller |
File |
File |
NVMe Hard Drive |
NVMe Hard Drive |
NVDIMM |
NVDIMM |
EnclosureNumber
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | Enclosure number value. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
FunctionNumber
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | PCI device function number value. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
LocationString
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | Text representation of the UEFI device location, in UTF-8 format |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
SegmentNumber
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | PCI segment group number value. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
StructuredName
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | PCI device structured name in UTF-8 format. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
SubclassCode
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | PCI sub class code of the endpoint. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
SubsystemDeviceID
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | PCI subsystem device ID of the device. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
SubsystemVendorID
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | PCI subsystem vendor ID of the device. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
UEFIDevicePath
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | Standardized text representation of the UEFI device path, in UTF-8 format. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
VendorID
Member of HpeServerPciDevice.v2_1_0.HpeServerPciDevice
Description | PCI vendor ID of the device. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeServerPciDeviceCollection.HpeServerPciDeviceCollection
@odata.type: "#HpeServerPciDeviceCollection.HpeServerPciDeviceCollection"
A Collection of HpeServerPciDevice resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/pcidevices |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeServerPciDevice |
Members (array)
Member of HpeServerPciDeviceCollection.HpeServerPciDeviceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeServerPciDeviceCollection.HpeServerPciDeviceCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeServerPciDeviceCollection.HpeServerPciDeviceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeServerPCISlot.v2_2_0.HpeServerPCISlot
@odata.type: "#HpeServerPCISlot.v2_2_0.HpeServerPCISlot"
The HpeServerPCISlot resource describes the properties of PCI slots.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/pcislots/{item} |
GET |
BusNumber
Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | PCI slot bus number. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Characteristics
Characteristics.Provides3_3Volts Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | Provides 3.3 volts. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Characteristics.Provides5Volts Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | Provides 5.0 volts. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Characteristics.SlotIsShared Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | The slot shares its opening with another slot. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Characteristics.SupportsCardBus Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | PC Card slot supports Card Bus. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Characteristics.SupportsHotPlugDevices Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | Slot supports hot-plug devices. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Characteristics.SupportsModemRingResume Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | PC Card slot supports Modem Ring Resume. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Characteristics.SupportsPCCard16 Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | PC Card slot supports PC Card-16. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Characteristics.SupportsPowerManagementEventSignal Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | PCI slot supports Power Management Event signal. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Characteristics.SupportsSMBusSignal Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | PCI slot supports SMBUS signal. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Characteristics.SupportsZoomVideo Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | PC Card slot supports Zoom Video. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
DeviceNumber
Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | PCI slot device number. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
FunctionNumber
Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | PCI slot function number. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Length
Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | PCI slot length |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Short |
Long |
Other |
LinkLanes
Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | Bandwidth capacity of the slot, measured by the number of PCI Express Lanes present. Also known as the slot width. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
8 bit |
16 bit |
32 bit |
64 bit |
128 bit |
x1 |
x2 |
x4 |
x8 |
x16 |
x32 |
Other |
SegmentNumber
Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | PCI slot segment group number value. |
Type | integer |
Read Only | True |
Added | iLO6 1.30 |
Status
Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot See the Redfish standard schema and specification for information on common Status object.
SupportsHotPlug
Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | Specifies whether the slot supports hot-plug devices. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Technology
Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | PCI technology |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Proprietary |
OCP NIC 3.0 |
PCIExpressGen5 |
PCIExpressGen4 |
PCIExpressGen3 |
PCIExpressGen2 |
PCIExpress |
UEFIDevicePath
Member of HpeServerPCISlot.v2_2_0.HpeServerPCISlot
Description | Standardized text representation of the UEFI device path, in UTF-8 format |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
HpeServerPCISlotCollection.HpeServerPCISlotCollection
@odata.type: "#HpeServerPCISlotCollection.HpeServerPCISlotCollection"
A Collection of HpeServerPCISlot resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/pcislots |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeServerPCISlot |
Members (array)
Member of HpeServerPCISlotCollection.HpeServerPCISlotCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeServerPCISlotCollection.HpeServerPCISlotCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeServerPCISlotCollection.HpeServerPCISlotCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeSNMPAlertDestination.v2_0_0.HpeSNMPAlertDestination
@odata.type: "#HpeSNMPAlertDestination.v2_0_0.HpeSNMPAlertDestination"
The HpeSNMPAlertDestination resource describes the properties for SNMP Alert Destinations. The alert destination configuration up to 8 remote management systems that receive SNMP alerts from the BMC.
This resource type was added in iLO 5 1.20
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/snmpservice/snmpalertdestinations/{item} |
GET PATCH DELETE |
AlertDestination
Member of HpeSNMPAlertDestination.v2_0_0.HpeSNMPAlertDestination
Description | The IP address or FQDN of remote management system that receive SNMP alerts. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
SNMPAlertProtocol
Member of HpeSNMPAlertDestination.v2_0_0.HpeSNMPAlertDestination
Description | Indicate the SNMP protocol associated with the AlertDestination. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
SNMPv1Trap |
Indicate SNMPv1 trap is enabled for the destination. |
SNMPv3Trap |
Indicate SNMPv3 trap is enabled for the destination. Needs to fill the SecurityName as well. |
SNMPv3Inform |
Indicate SNMPv3 Inform is enabled for the destination. Needs to fill the SecurityName as well. |
Null |
A value is temporarily unavailable |
SNMPv3User
SNMPv3 User associated with the destination when SNMP alert protocol is SNMPv3trap.
SNMPv3User is a link ("@odata.id": URI
) to another resource.
SecurityName
Member of HpeSNMPAlertDestination.v2_0_0.HpeSNMPAlertDestination
Description | Provides the SNMPv3 security name associated with SNMPv3trap or SNMPv3Inform set on SNMPAlertProtocol. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
TrapCommunity
Member of HpeSNMPAlertDestination.v2_0_0.HpeSNMPAlertDestination
Description | The configured SNMPv1 trap community string. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
HpeSNMPAlertDestinationCollection.HpeSNMPAlertDestinationCollection
@odata.type: "#HpeSNMPAlertDestinationCollection.HpeSNMPAlertDestinationCollection"
A Collection of HpeSNMPAlertDestination resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/snmpservice/snmpalertdestinations |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeSNMPAlertDestination |
Members (array)
Member of HpeSNMPAlertDestinationCollection.HpeSNMPAlertDestinationCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeSNMPAlertDestinationCollection.HpeSNMPAlertDestinationCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeSNMPAlertDestinationCollection.HpeSNMPAlertDestinationCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeSNMPUser.v2_1_0.HpeSNMPUser
@odata.type: "#HpeSNMPUser.v2_1_0.HpeSNMPUser"
The HpeSNMPUser resource describes the properties for SNMP support. SNMPv3 supports the User-based Security Model (USM). With this model,security parameters are configured at both the agent level and the manager level. Messages exchanged between the agent and the manager are subject to a data integrity check and data origin authentication. Up to 8 user profiles are supported for setting SNMPv3 USM parameters.
This resource type was added in iLO 5 1.20
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/snmpservice/snmpusers/{item} |
GET PATCH DELETE |
AuthPassphrase
Member of HpeSNMPUser.v2_1_0.HpeSNMPUser
Description | Sets the passphrase to use for sign operations. Enter a value of 8 to 49 characters. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
AuthProtocol
Member of HpeSNMPUser.v2_1_0.HpeSNMPUser
Description | Sets the message digest algorithm to use for encoding the authorization passphrase. The message digest is calculated over an appropriate portion of an SNMP message, and is included as part of the message sent to the recipient. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
MD5 |
Indicate Message Digest Algorithm. |
SHA |
Indicate Secure Hash Algorithm. |
SHA256 |
Indicate SHA256 Algorithm. |
PrivacyPassphrase
Member of HpeSNMPUser.v2_1_0.HpeSNMPUser
Description | Sets the passphrase to use for encrypt operations. Enter a value of 8 to 49 characters. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
PrivacyProtocol
Member of HpeSNMPUser.v2_1_0.HpeSNMPUser
Description | Sets the encryption algorithm to use for encoding the privacy passphrase. A portion of an SNMP message is encrypted before transmission. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
DES |
Indicate Data Encryption Standard Algorithm. |
AES |
Indicate Advanced Encryption Standard Algorithm. |
SecurityName
Member of HpeSNMPUser.v2_1_0.HpeSNMPUser
Description | The user profile name. Enter an alphanumeric string of 1 to 32 characters. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
UserEngineID
Member of HpeSNMPUser.v2_1_0.HpeSNMPUser
Description | The UserEngineID is combined with the SecurityName to create a SNMPv3 user for each manager. It is only used for creating remote accounts used with INFORM messages. If this property is not set then INFORM message will be sent with default or iLO configured engine ID. This value must be a hexadecimal string with an even number of 10 to 64 characters, excluding the first two characters, 0x (for example, 0x01020304abcdef). |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
HpeSNMPUsersCollection.HpeSNMPUsersCollection
@odata.type: "#HpeSNMPUsersCollection.HpeSNMPUsersCollection"
A Collection of HpeSNMPUsers resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/snmpservice/snmpusers |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeSNMPUser |
Members (array)
Member of HpeSNMPUsersCollection.HpeSNMPUsersCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeSNMPUsersCollection.HpeSNMPUsersCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeSNMPUsersCollection.HpeSNMPUsersCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeTlsConfig.v1_0_0.HpeTlsConfig
@odata.type: "#HpeTlsConfig.v1_0_0.HpeTlsConfig"
The schema definition for TLS configuration.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bios/tlsconfig |
GET |
/redfish/v1/systems/{item}/bios/tlsconfig/settings |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
@Redfish.Settings/SettingsObject |
HpeTlsConfig |
Oem/Hpe/Links/BaseConfigs |
HpeBaseConfigs |
@Redfish.Settings
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig See the Redfish standard schema and specification for information on common @Redfish properties.
Certificates (array)
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Certificates
is an array containing elements of:
Certificates[{item}].FingerPrint Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The fingerprint of the certificate. It is the sha256 (SHA2) of the Der format of the certificate |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Certificates[{item}].Issuer Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The Issuer of the certificate |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Certificates[{item}].SerialNumber Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The Serial Number of the certificate. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Certificates[{item}].Subject Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The Subject of the certificate. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Certificates[{item}].ValidNotAfter Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The expiration date of the certificate. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Certificates[{item}].ValidNotBefore Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The date when the certificate becomes valid. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Ciphers
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The encryption used. It can have more than one type of encryption, example: “AES128-SHA:AES256-SHA:AES128-SHA256:AES256-SHA256” |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
DeleteCertificates (array)
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
DeleteCertificates
is an array containing elements of:
DeleteCertificates[{item}].FingerPrint Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | To delete a certificate, the user should place its fingerprint here. The fingerprint would be found as a property under the single certificate object in the “Certificates” array |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
HostnameCheck
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | Use this option to enable or disable verification of the connected server’s hostname with the hostname in the certificate supplied by the server |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Disable verification of the connected server’s hostname. |
Enabled |
enable verification of the connected server’s hostname. |
NewCertificates (array)
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
NewCertificates
is an array containing elements of:
NewCertificates[{item}].X509Certificate Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | the body (PEM format) of the Certificate to be added |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
ProtocolVersion
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
AUTO |
1.0 |
1.1 |
1.2 |
1.3 |
TlsCaCertificateCount
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | The certificates count. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
VerifyMode
Member of HpeTlsConfig.v1_0_0.HpeTlsConfig
Description | It determines if/how the certificates are validated. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
NONE |
PEER |
HpeUSBDevice.v2_0_0.HpeUSBDevice
@odata.type: "#HpeUSBDevice.v2_0_0.HpeUSBDevice"
The HpeUSBDevice resource describes the properties of USB devices.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/usbdevices/{item} |
GET |
DeviceCapacityMB
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | USB device usable capacity (if applicable) in Mbytes |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
DeviceClass
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | USB device Class code as defined by the USB HID device specification. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
DeviceName
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | USB device name in UTF-8 format. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
DeviceProtocol
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | Protocol code as defined by the USB HID specification. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
DeviceSubClass
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | USB device SubClass code as defined by the USB HID device specification. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Location
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | Location of the USB device on the server |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProductID
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | USB product ID as defined by manufacturer. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
StructuredName
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | USB device structured name in UTF-8 format. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
UEFIDevicePath
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | UEFI device path of USB device. Standardized text representation of the UEFI device path, in UTF-8 format |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
VendorID
Member of HpeUSBDevice.v2_0_0.HpeUSBDevice
Description | Vendor ID of detected USB device. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeUSBDevicesCollection.HpeUSBDevicesCollection
@odata.type: "#HpeUSBDevicesCollection.HpeUSBDevicesCollection"
A Collection of HpeUSBDevices resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/usbdevices |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeUSBDevice |
Members (array)
Member of HpeUSBDevicesCollection.HpeUSBDevicesCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeUSBDevicesCollection.HpeUSBDevicesCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeUSBDevicesCollection.HpeUSBDevicesCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeUSBPort.v2_0_0.HpeUSBPort
@odata.type: "#HpeUSBPort.v2_0_0.HpeUSBPort"
The HpeUSBPort resource describes the properties of USB ports.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/usbports/{item} |
GET |
InstanceNumber
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | Instance number of the USB Port |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Location
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | Location of the USB Device on the server |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Back |
Located on the rear panel of the server. |
Front |
Located on the front bezel of the server. |
Internal |
Located internally within the server chassis. |
InternalManagement |
Internal management media. |
InternalSDCard |
The internal SD-Card slot. |
iLOManagement |
iLO virtual USB devices. |
PCIBusNumber
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | PCI Bus number of the USB controller that controls this USB port |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PCIDeviceNumber
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | PCI Device Number of the USB Controller that controls this USB Port. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PCIFunctionNumber
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | PCI Function Number of the USB Controller that controls this USB Port. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
ParentHubInstance
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | Parent Hub Instance that provides an instance number of the internal hub this USB Port is connected to. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
SharedCapability
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | Shared Capability of the USB Port |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
UnsharedManagement |
Not shared as a Management Port. |
SharedManagementPhysicalSwitch |
Shared management port w/ physical switch to control whether muxed to iLO or host. |
SharedManagementPortAutomaticControl |
SpeedCapability
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | USB speed capability of the USB port as configured by the BIOS during POST. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
USB1FullSpeed |
USB 1.0 Full Speed |
USB2HighSpeed |
USB 2.0 High Speed |
USB3SuperSpeed |
USB 3.x SuperSpeed |
UEFIDevicePath
Member of HpeUSBPort.v2_0_0.HpeUSBPort
Description | UEFI Device Path of USB Endpoint. Standardized text representation of the UEFI device path, in UTF-8 format |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
HpeUSBPortsCollection.HpeUSBPortsCollection
@odata.type: "#HpeUSBPortsCollection.HpeUSBPortsCollection"
A Collection of HpeUSBPorts resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/usbports |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeUSBPort |
Members (array)
Member of HpeUSBPortsCollection.HpeUSBPortsCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeUSBPortsCollection.HpeUSBPortsCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeUSBPortsCollection.HpeUSBPortsCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor
@odata.type: "#HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor"
The HpeWorkloadPerformanceAdvisor resource describes the properties for managing the HPE Workload Performance Advisor.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/workloadperformanceadvisor/{item} |
GET |
Duration
Member of HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor
Description | Specifies the duration over which the workload performance advisor is computed. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PerformanceTuningOption (array)
Member of HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor
PerformanceTuningOption
is an array containing elements of:
PerformanceTuningOption[{item}].BIOSAttributeName Member of HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor
Description | The attribute name of the BIOS settings. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
PerformanceTuningOption[{item}].RecommendedValue Member of HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor
Description | Recommended value for the corresponding BIOS attribute. Please refer to BIOS attribute registry schema for more information. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
WorkloadCharacteristics (array)
Member of HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor
WorkloadCharacteristics
is an array containing elements of:
WorkloadCharacteristics[{item}].MetricId Member of HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor
Description | The id of the metric. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
WorkloadCharacteristics[{item}].MetricValue Member of HpeWorkloadPerformanceAdvisor.v1_0_0.HpeWorkloadPerformanceAdvisor
Description | The workload utilization of the metric. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Low |
Utilization is low. |
Medium |
Utilization is medium. |
High |
Utilization is high. |
HpeWorkloadPerformanceAdvisorCollection.HpeWorkloadPerformanceAdvisorCollection
@odata.type: "#HpeWorkloadPerformanceAdvisorCollection.HpeWorkloadPerformanceAdvisorCollection"
A Collection of HpeWorkloadPerformanceAdvisor resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/workloadperformanceadvisor |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HpeWorkloadPerformanceAdvisor |
Members (array)
Member of HpeWorkloadPerformanceAdvisorCollection.HpeWorkloadPerformanceAdvisorCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HpeWorkloadPerformanceAdvisorCollection.HpeWorkloadPerformanceAdvisorCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HpeWorkloadPerformanceAdvisorCollection.HpeWorkloadPerformanceAdvisorCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
JsonSchemaFile.v1_0_4.JsonSchemaFile
@odata.type: "#JsonSchemaFile.v1_0_4.JsonSchemaFile"
The JSON Schema File resource describes the location (URI) of a particular Redfish schema definition being implemented or referenced by a Redfish service.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/jsonschemas/{item} |
GET |
Languages (array)
Member of JsonSchemaFile.v1_0_4.JsonSchemaFile
Languages
is an array containing elements of:
Languages[{item}] Member of JsonSchemaFile.v1_0_4.JsonSchemaFile
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Location (array)
Member of JsonSchemaFile.v1_0_4.JsonSchemaFile
Location
is an array containing elements of:
Location[{item}].Language Member of JsonSchemaFile.v1_0_4.JsonSchemaFile
Description | The RFC 5646 language code for this schema or registry item. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Location[{item}].Uri Member of JsonSchemaFile.v1_0_4.JsonSchemaFile
Description | Link to locally available URI for schema. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Schema
Member of JsonSchemaFile.v1_0_4.JsonSchemaFile
Description | The typename this schema describes. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
JsonSchemaFileCollection.JsonSchemaFileCollection
@odata.type: "#JsonSchemaFileCollection.JsonSchemaFileCollection"
A Collection of JsonSchemaFile resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/jsonschemas |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
JsonSchemaFile |
Members (array)
Member of JsonSchemaFileCollection.JsonSchemaFileCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of JsonSchemaFileCollection.JsonSchemaFileCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of JsonSchemaFileCollection.JsonSchemaFileCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
LogEntry.v1_11_0.LogEntry
@odata.type: "#LogEntry.v1_11_0.LogEntry"
This resource defines the record format for a log. It is designed to be used for SEL logs (from IPMI) as well as Event Logs and OEM-specific log formats. The EntryType field indicates the type of log and the resource includes several additional properties dependent on the EntryType.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/logservices/iel/entries/{item} |
GET |
/redfish/v1/managers/{item}/remotesupportservice/serviceeventlogs/{item} |
GET |
/redfish/v1/systems/{item}/logservices/dpu/entries/{item} |
GET PATCH |
/redfish/v1/systems/{item}/logservices/event/entries/{item} |
GET |
/redfish/v1/systems/{item}/logservices/iml/entries/{item} |
GET PATCH |
/redfish/v1/systems/{item}/logservices/sl/entries/{item} |
GET |
Created
Member of LogEntry.v1_11_0.LogEntry
Description | The date and time when the log entry was created, for example, 2014-04-15T00:38:00Z. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
EntryType
Member of LogEntry.v1_11_0.LogEntry
Description | The log entry type. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Oem |
EventId
Member of LogEntry.v1_11_0.LogEntry
Description | The unique instance identifier for an event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
EventTimestamp
Member of LogEntry.v1_11_0.LogEntry
Description | The date and time when the event occurred. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Message
Member of LogEntry.v1_11_0.LogEntry
Description | The log entry details. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
MessageArgs (array)
Member of LogEntry.v1_11_0.LogEntry
MessageArgs
is an array containing elements of:
MessageArgs[{item}] Member of LogEntry.v1_11_0.LogEntry
Type | string |
Read Only | True |
Added | iLO6 1.05 |
MessageId
Member of LogEntry.v1_11_0.LogEntry
Description | The MessageId, event data, or OEM-specific information. This property decodes from the entry type. If the entry type is Event , this property contains a Redfish Specification-defined MessageId. If the entry type is SEL , this property contains the Event Data. Otherwise, this property contains OEM-specific information. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Categories (array)
Member of LogEntry.v1_11_0.LogEntry
Categories
is an array containing elements of:
Categories[{item}] Member of LogEntry.v1_11_0.LogEntry
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Security |
Hardware |
Firmware |
Maintenance |
Administration |
Power |
Cooling |
Invalid User Input |
Other |
Configuration |
Oem.Hpe.Class
Member of LogEntry.v1_11_0.LogEntry
Description | The log entry event class. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ClassDescription
Member of LogEntry.v1_11_0.LogEntry
Description | The log entry event class description. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Code
Member of LogEntry.v1_11_0.LogEntry
Description | The log entry event code. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Count
Member of LogEntry.v1_11_0.LogEntry
Description | The occurrence count of the log entry. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Destination
Member of LogEntry.v1_11_0.LogEntry
Description | The destination host name or IP address of the remote server that recevied the service event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EventNumber
Member of LogEntry.v1_11_0.LogEntry
Description | The event log identification number. Events are numbered in the order in which they are generated. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Identifier
Member of LogEntry.v1_11_0.LogEntry
Description | The unique identifier of the service event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LearnMoreLink
Member of LogEntry.v1_11_0.LogEntry
Description | The link to troubleshooting information. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Oem.Hpe.RecommendedAction
Member of LogEntry.v1_11_0.LogEntry
Description | The recommended action for the event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Repaired
Member of LogEntry.v1_11_0.LogEntry
Description | The repaired status of the IML event. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.ServiceEvent
Member of LogEntry.v1_11_0.LogEntry
Description | This indicates a service ticket to be raised for the corresponding event log. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ServiceEventMessageID
Member of LogEntry.v1_11_0.LogEntry
Description | This property represents the Embedded Remote Support Message ID. It is applicable only for a Service Event log. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Severity
Member of LogEntry.v1_11_0.LogEntry
Description | The log entry event Severity. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Informational |
Informational event |
Caution |
Caution event |
Critical |
Critical event |
Repaired |
Critical or Caution event repaired |
Oem.Hpe.SubmitStatus
Member of LogEntry.v1_11_0.LogEntry
Description | The service event log submission status . |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Updated
Member of LogEntry.v1_11_0.LogEntry
Description | The date and time of the latest log entry update, for example, 2014-04-15T00:38:00Z. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Oem.Hpe.UserAction
Member of LogEntry.v1_11_0.LogEntry
Description | The User action for the event. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Repaired |
The event repaired by user. |
Ignored |
The event ignored by user. |
None |
No user action taken on the event. |
Not Applicable |
User action not applicable for the event. |
OemRecordFormat
Member of LogEntry.v1_11_0.LogEntry
Description | The format of an OEM record. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Hpe-IML |
Hpe-iLOEventLog |
Hpe-SL |
Hpe-Event |
Severity
Member of LogEntry.v1_11_0.LogEntry
Description | The log entry severity. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
OK |
Warning |
Critical |
LogEntryCollection.LogEntryCollection
@odata.type: "#LogEntryCollection.LogEntryCollection"
A Collection of LogEntry resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/logservices/iel/entries |
GET POST |
/redfish/v1/managers/{item}/remotesupportservice/serviceeventlogs |
GET |
/redfish/v1/systems/{item}/logservices/dpu/entries |
GET POST |
/redfish/v1/systems/{item}/logservices/event/entries |
GET POST |
/redfish/v1/systems/{item}/logservices/iml/entries |
GET POST |
/redfish/v1/systems/{item}/logservices/sl/entries |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
LogEntry |
Members (array)
Member of LogEntryCollection.LogEntryCollection
Members
is an array containing elements of:
Members[{item}].@odata.context Member of LogEntryCollection.LogEntryCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members[{item}].@odata.etag Member of LogEntryCollection.LogEntryCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].@odata.id Member of LogEntryCollection.LogEntryCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members[{item}].@odata.type Member of LogEntryCollection.LogEntryCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Created Member of LogEntryCollection.LogEntryCollection
Description | The date and time when the log entry was created, for example, 2014-04-15T00:38:00Z. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Members[{item}].EntryType Member of LogEntryCollection.LogEntryCollection
Description | The log entry type. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Oem |
Members[{item}].EventId Member of LogEntryCollection.LogEntryCollection
Description | The unique instance identifier for an event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].EventTimestamp Member of LogEntryCollection.LogEntryCollection
Description | The date and time when the event occurred. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Members[{item}].Links
Members[{item}].Links.OriginOfCondition
The link to the resource that caused the log entry.
OriginOfCondition is a link ("@odata.id": URI
) to another resource.
Members[{item}].Message Member of LogEntryCollection.LogEntryCollection
Description | The log entry details. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].MessageArgs (array)
Member of LogEntryCollection.LogEntryCollection
MessageArgs
is an array containing elements of:
MessageArgs[{item}] Member of LogEntryCollection.LogEntryCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].MessageId Member of LogEntryCollection.LogEntryCollection
Description | The MessageId, event data, or OEM-specific information. This property decodes from the entry type. If the entry type is Event , this property contains a Redfish Specification-defined MessageId. If the entry type is SEL , this property contains the Event Data. Otherwise, this property contains OEM-specific information. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Categories (array)
Member of LogEntryCollection.LogEntryCollection
Categories
is an array containing elements of:
Categories[{item}] Member of LogEntryCollection.LogEntryCollection
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Security |
Hardware |
Firmware |
Maintenance |
Administration |
Power |
Cooling |
Invalid User Input |
Other |
Configuration |
Members[{item}].Oem.Hpe.Class Member of LogEntryCollection.LogEntryCollection
Description | The log entry event class. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.ClassDescription Member of LogEntryCollection.LogEntryCollection
Description | The log entry event class description. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Code Member of LogEntryCollection.LogEntryCollection
Description | The log entry event code. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Count Member of LogEntryCollection.LogEntryCollection
Description | The occurrence count of the log entry. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Destination Member of LogEntryCollection.LogEntryCollection
Description | The destination host name or IP address of the remote server that recevied the service event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.EventNumber Member of LogEntryCollection.LogEntryCollection
Description | The event log identification number. Events are numbered in the order in which they are generated. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Identifier Member of LogEntryCollection.LogEntryCollection
Description | The unique identifier of the service event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.LearnMoreLink Member of LogEntryCollection.LogEntryCollection
Description | The link to troubleshooting information. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members[{item}].Oem.Hpe.RecommendedAction Member of LogEntryCollection.LogEntryCollection
Description | The recommended action for the event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Repaired Member of LogEntryCollection.LogEntryCollection
Description | The repaired status of the IML event. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.ServiceEvent Member of LogEntryCollection.LogEntryCollection
Description | This indicates a service ticket to be raised for the corresponding event log. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.ServiceEventMessageID Member of LogEntryCollection.LogEntryCollection
Description | This property represents the Embedded Remote Support Message ID. It is applicable only for a Service Event log. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Severity Member of LogEntryCollection.LogEntryCollection
Description | The log entry event Severity. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Informational |
Informational event |
Caution |
Caution event |
Critical |
Critical event |
Repaired |
Critical or Caution event repaired |
Members[{item}].Oem.Hpe.SubmitStatus Member of LogEntryCollection.LogEntryCollection
Description | The service event log submission status . |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Updated Member of LogEntryCollection.LogEntryCollection
Description | The date and time of the latest log entry update, for example, 2014-04-15T00:38:00Z. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Members[{item}].Oem.Hpe.UserAction Member of LogEntryCollection.LogEntryCollection
Description | The User action for the event. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Repaired |
The event repaired by user. |
Ignored |
The event ignored by user. |
None |
No user action taken on the event. |
Not Applicable |
User action not applicable for the event. |
Members[{item}].OemRecordFormat Member of LogEntryCollection.LogEntryCollection
Description | The format of an OEM record. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Hpe-IML |
Hpe-iLOEventLog |
Hpe-SL |
Hpe-Event |
Members[{item}].Severity Member of LogEntryCollection.LogEntryCollection
Description | The log entry severity. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
OK |
Warning |
Critical |
Members@odata.count
Member of LogEntryCollection.LogEntryCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
LogService.v1_1_0.LogService
@odata.type: "#LogService.v1_1_0.LogService"
This resource contains properties for monitoring and configuring an event log service for the resource or service to which it is associated.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/logservices/iel |
GET POST |
/redfish/v1/systems/{item}/logservices/dpu |
GET POST |
/redfish/v1/systems/{item}/logservices/event |
GET POST |
/redfish/v1/systems/{item}/logservices/iml |
GET POST |
/redfish/v1/systems/{item}/logservices/sl |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Entries |
Collection of LogEntry |
DateTime
Member of LogService.v1_1_0.LogService
Description | The current date and time, with UTC offset, that the Log Service uses to set or read time. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Format | date-time |
DateTimeLocalOffset
Member of LogService.v1_1_0.LogService
Description | The UTC offset that the current DateTime proeprtu value contains in the +HH:MM format. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Entries
The URI to this log entries collection resource.
Entries is a link ("@odata.id": URI
) to another resource.
MaxNumberOfRecords
Member of LogService.v1_1_0.LogService
Description | The maximum number of log entries. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
OverWritePolicy
Member of LogService.v1_1_0.LogService
Description | When the log is full, the overwrite policy is enforced. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Unknown |
The overwrite policy is not known or is undefined. |
WrapsWhenFull |
When the log is full, new entries will overwrite previous entries. |
NeverOverwrites |
When the log is full, new entries are discarded. |
ServiceEnabled
Member of LogService.v1_1_0.LogService
Description | An indication of whether this service is enabled. |
Type | boolean |
Read Only | True |
Added | iLO6 1.10 |
Status
Member of LogService.v1_1_0.LogService See the Redfish standard schema and specification for information on common Status object.
Actions
LogService.ClearLog Member of LogService.v1_1_0.LogService There are no parameters for this action.
LogServiceCollection.LogServiceCollection
@odata.type: "#LogServiceCollection.LogServiceCollection"
A Collection of LogService resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/logservices |
GET |
/redfish/v1/systems/{item}/logservices |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
LogService |
Members (array)
Member of LogServiceCollection.LogServiceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of LogServiceCollection.LogServiceCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of LogServiceCollection.LogServiceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Manager.v1_5_1.Manager
@odata.type: "#Manager.v1_5_1.Manager"
The Manager resource describes a manager. Examples of managers are BMCs, Enclosure Managers, Management Controllers and other subsystems assigned manageability functions.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item} |
GET POST PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Oem/Hpe/Links/DateTimeService |
HpeiLODateTime |
Oem/Hpe/Links/RemoteSupport |
HpeRemoteSupport |
Links/ManagerForChassis[] |
Chassis |
SerialInterfaces |
Collection of SerialInterface |
VirtualMedia |
Collection of VirtualMedia |
LogServices |
Collection of LogService |
Links/ManagerInChassis |
Chassis |
EthernetInterfaces |
Collection of EthernetInterface |
Links/ManagerForServers[] |
ComputerSystem |
Oem/Hpe/Links/ActiveHealthSystem |
HpeiLOActiveHealthSystem |
Oem/Hpe/Links/SecurityService |
HpeSecurityService |
Oem/Hpe/Links/LicenseService |
Collection of HpeiLOLicense |
NetworkProtocol |
ManagerNetworkProtocol |
Oem/Hpe/Links/FederationPeers |
Collection of HpeiLOFederationPeers |
HostInterfaces |
Collection of HostInterface |
Oem/Hpe/Links/EmbeddedMediaService |
HpeiLOEmbeddedMedia |
Oem/Hpe/Links/FederationGroups |
Collection of HpeiLOFederationGroup |
Oem/Hpe/Links/BackupRestoreService |
HpeiLOBackupRestoreService |
CommandShell
CommandShell.ConnectTypesSupported (array)
Member of Manager.v1_5_1.Manager
ConnectTypesSupported
is an array containing elements of:
ConnectTypesSupported[{item}] Member of Manager.v1_5_1.Manager
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
SSH |
The controller supports a Command Shell connection using the SSH protocol |
Telnet |
The controller supports a Command Shell connection using the Telnet protocol |
IPMI |
The controller supports a Command Shell connection using the IPMI Serial-over-LAN (SOL) protocol |
Oem |
The controller supports a Command Shell connectino using an OEM-specific protocol |
CommandShell.MaxConcurrentSessions Member of Manager.v1_5_1.Manager
Description | This is the maximum number of Command Shell sessions, regardless of protocol, that this manager supports. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CommandShell.ServiceEnabled Member of Manager.v1_5_1.Manager
Description | Indicates if the Command Shell service is enabled for this manager. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
DateTime
Member of Manager.v1_5_1.Manager
Description | The current DateTime (with offset) for the manager, used to set or read time. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
DateTimeLocalOffset
Member of Manager.v1_5_1.Manager
Description | The time offset from UTC that the DateTime property is set to in format: +06:00 . |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
EthernetInterfaces
This is a reference to a collection of NICs that this manager uses for network communication. It is here that clients will find NIC configuration options and settings.
EthernetInterfaces is a link ("@odata.id": URI
) to another resource.
FirmwareVersion
Member of Manager.v1_5_1.Manager
Description | The firmware version of this Manager |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
GraphicalConsole
GraphicalConsole.ConnectTypesSupported (array)
Member of Manager.v1_5_1.Manager
ConnectTypesSupported
is an array containing elements of:
ConnectTypesSupported[{item}] Member of Manager.v1_5_1.Manager
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
KVMIP |
The controller supports a Graphical Console connection using a KVM-IP (redirection of Keyboard, Video, Mouse over IP) protocol |
Oem |
The controller supports a Graphical Console connection using an OEM-specific protocol |
GraphicalConsole.MaxConcurrentSessions Member of Manager.v1_5_1.Manager
Description | Indicates the maximum number of Graphical Console sessions, regardless of protocol, this manager supports. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
GraphicalConsole.ServiceEnabled Member of Manager.v1_5_1.Manager
Description | Indicates if the Command Shell service is enabled for this manager. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
HostInterfaces
This is a reference to a collection of Host Interfaces that this manager uses for local host communication. It is here that clients will find Host Interface configuration options and settings.
HostInterfaces is a link ("@odata.id": URI
) to another resource.
LogServices
Reference to a resource of type Collection with a MemberType of Logs.
LogServices is a link ("@odata.id": URI
) to another resource.
ManagerType
Member of Manager.v1_5_1.Manager
Description | This property is the manager type for this resource. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ManagementController |
A controller used primarily to monitor or manage the operation of a device or system |
EnclosureManager |
A controller which provides management functions for a chassis or group of devices or systems |
BMC |
A controller which provides management functions for a single computer system |
Model
Member of Manager.v1_5_1.Manager
Description | Model name of the manager. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
NetworkProtocol
This is a reference to the network services and their settings that the manager controls. It is here that clients will find network configuration options as well as network services.
NetworkProtocol is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.ClearRestApiStatus
Member of Manager.v1_5_1.Manager
Description | Status of external provider data in NVRAM. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
DataPresent |
External Provider data is present in NVRAM. |
DataCleared |
External Provider data is not present in NVRAM. |
Oem.Hpe.CloudConnect
Oem.Hpe.CloudConnect.ActivationKey Member of Manager.v1_5_1.Manager
Description | The activation key is the customer account ID of HPE GreenLake. Obtain the account ID by visiting HPE GreenLake portal-Manage->Account Details card. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.CloudConnect.CloudConnectStatus Member of Manager.v1_5_1.Manager
Description | Indicates the current status of cloud connection. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NotEnabled |
Indicates the initial state of the system or cloud connect service is disabled. |
ConnectionInProgress |
Indicates the cloud activation or connection to the communication service is in progress |
ConnectionFailed |
Indicates the cloud activation could not be completed and and the retry attempts for activation also failed |
Connected |
Indicates the cloud connect enabled, activation successful and connection to communication service successful |
RetryInProgress |
Indicates a connection issue with the communication service and being retried for a successful communication |
NotConnected |
Indicates the connection retries to the communication service has failed and periodic retries will be attempted |
Oem.Hpe.CloudConnect.FailReason Member of Manager.v1_5_1.Manager
Description | Indicates the reason for cloud connection failure. |
Type | string |
Read Only | True |
Added | iLO6 1.30 |
The following are the supported values:
Value | Description |
---|---|
iLOTimeError |
Indicates the cloud activation failed due to incorrect iLO time. |
NetworkError |
Indicates the cloud activation failed due to network issues. |
ProxyError |
Indicates the cloud activation failed due to Proxy errors. |
ActivationKeyMissing |
Indicates the cloud activation failed due to missing activation key. |
WrongActivationKey |
Indicates the cloud activation failed due to wrong activation key errors. |
WrongiLOVersion |
Indicates the cloud activation failed due to wrong iLO version errors. |
Oem.Hpe.CloudConnect.NextRetryTime Member of Manager.v1_5_1.Manager
Description | Indicates the timestamp of next retry event. |
Type | string |
Read Only | True |
Added | iLO6 1.40 |
Oem.Hpe.ConfigurationLimitations
Member of Manager.v1_5_1.Manager
Description | Limitations on configuration change based on node type. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
None |
No user interface configuration limitations are in effect. |
ManagedNode |
This is a managed node. User interfaces that are required for management cannot be modified. |
Oem.Hpe.ConfigurationSettings
Member of Manager.v1_5_1.Manager
Description | State of the currently displayed configuration settings. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Current |
SomePendingReset |
Oem.Hpe.FederationConfig
Oem.Hpe.FederationConfig.IPv6MulticastScope Member of Manager.v1_5_1.Manager
Description | The IPv6 network scope of multicast announcements. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Link |
Site |
Organization |
Oem.Hpe.FederationConfig.MulticastAnnouncementInterval Member of Manager.v1_5_1.Manager
Description | The frequency in Seconds at which the iLO system announces itself on the network. A value of 0 disables multicast announcments. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Null |
30 |
60 |
120 |
300 |
600 |
900 |
1800 |
Oem.Hpe.FederationConfig.MulticastDiscovery Member of Manager.v1_5_1.Manager
Description | Enables or Disables Multicast Discovery for the local iLO system. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Enabled |
Disabled |
Oem.Hpe.FederationConfig.MulticastTimeToLive Member of Manager.v1_5_1.Manager
Description | The maximum number of switches a multicast announcement will traverse before being discarded. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.FederationConfig.iLOFederationManagement Member of Manager.v1_5_1.Manager
Description | Enables or Disables iLO Federation features for the local iLO system. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Enabled |
Disabled |
Oem.Hpe.Firmware
Oem.Hpe.Firmware.Backup Oem.Hpe.Firmware.Backup.BuildNumber Member of Manager.v1_5_1.Manager
Description | The build number of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Backup.BuildNumberString Member of Manager.v1_5_1.Manager
Description | The string version of the build number of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Backup.Date Member of Manager.v1_5_1.Manager
Description | The build date of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Backup.DebugBuild Member of Manager.v1_5_1.Manager
Description | True if the firmware is a debug build; False if it is not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Backup.Family Member of Manager.v1_5_1.Manager
Description | The family of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Backup.MajorVersion Member of Manager.v1_5_1.Manager
Description | The major version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Backup.MinorVersion Member of Manager.v1_5_1.Manager
Description | The minor version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Backup.Time Member of Manager.v1_5_1.Manager
Description | The build time of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Backup.VersionString Member of Manager.v1_5_1.Manager
Description | The version string of the firmware. This value might be null if VersionString is unavailable. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Bootblock Oem.Hpe.Firmware.Bootblock.BuildNumber Member of Manager.v1_5_1.Manager
Description | The build number of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Bootblock.BuildNumberString Member of Manager.v1_5_1.Manager
Description | The string version of the build number of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Bootblock.Date Member of Manager.v1_5_1.Manager
Description | The build date of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Bootblock.DebugBuild Member of Manager.v1_5_1.Manager
Description | True if the firmware is a debug build; False if it is not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Bootblock.Family Member of Manager.v1_5_1.Manager
Description | The family of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Bootblock.MajorVersion Member of Manager.v1_5_1.Manager
Description | The major version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Bootblock.MinorVersion Member of Manager.v1_5_1.Manager
Description | The minor version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Bootblock.Time Member of Manager.v1_5_1.Manager
Description | The build time of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Bootblock.VersionString Member of Manager.v1_5_1.Manager
Description | The version string of the firmware. This value might be null if VersionString is unavailable. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Current Oem.Hpe.Firmware.Current.BuildNumber Member of Manager.v1_5_1.Manager
Description | The build number of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Current.BuildNumberString Member of Manager.v1_5_1.Manager
Description | The string version of the build number of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Current.Date Member of Manager.v1_5_1.Manager
Description | The build date of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Current.DebugBuild Member of Manager.v1_5_1.Manager
Description | True if the firmware is a debug build; False if it is not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Current.Family Member of Manager.v1_5_1.Manager
Description | The family of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Current.MajorVersion Member of Manager.v1_5_1.Manager
Description | The major version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Current.MinorVersion Member of Manager.v1_5_1.Manager
Description | The minor version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Current.Time Member of Manager.v1_5_1.Manager
Description | The build time of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Current.VersionString Member of Manager.v1_5_1.Manager
Description | The version string of the firmware. This value might be null if VersionString is unavailable. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Pending Oem.Hpe.Firmware.Pending.BuildNumber Member of Manager.v1_5_1.Manager
Description | The build number of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Pending.BuildNumberString Member of Manager.v1_5_1.Manager
Description | The string version of the build number of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Pending.Date Member of Manager.v1_5_1.Manager
Description | The build date of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Pending.DebugBuild Member of Manager.v1_5_1.Manager
Description | True if the firmware is a debug build; False if it is not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Pending.Family Member of Manager.v1_5_1.Manager
Description | The family of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Pending.MajorVersion Member of Manager.v1_5_1.Manager
Description | The major version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Pending.MinorVersion Member of Manager.v1_5_1.Manager
Description | The minor version of the firmware. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Pending.Time Member of Manager.v1_5_1.Manager
Description | The build time of the firmware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Firmware.Pending.VersionString Member of Manager.v1_5_1.Manager
Description | The version string of the firmware. This value might be null if VersionString is unavailable. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.FrontPanelUSB
Oem.Hpe.FrontPanelUSB.State Member of Manager.v1_5_1.Manager
Description | The state of the front USB port device. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Ready |
iLO has not detected a front panel device. |
Busy |
iLO has detected a front panel device and is initializing or executing operations on the device. |
Complete |
iLO has successfully finished initializing or executing operations on the device. |
Error |
iLO failed to initialize or execute operations on the device. |
Disabled |
The front panel device is disabled by user configuration. |
Oem.Hpe.IdleConnectionTimeoutMinutes
Member of Manager.v1_5_1.Manager
Description | This setting specifies how long a user can be inactive before an iLO web interface ends automatically. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Null |
15 |
30 |
60 |
120 |
Oem.Hpe.IntegratedRemoteConsole
Oem.Hpe.IntegratedRemoteConsole.HotKeys (array)
Member of Manager.v1_5_1.Manager
HotKeys
is an array containing elements of:
HotKeys[{item}].KeySequence (array)
Member of Manager.v1_5_1.Manager
KeySequence
is an array containing elements of:
KeySequence[{item}] Member of Manager.v1_5_1.Manager
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NONE |
No key |
ESC |
Escape key |
L_ALT |
Left Alt key |
R_ALT |
Right Alt key |
L_SHIFT |
Left Shift key |
R_SHIFT |
Right Shift key |
L_CTRL |
Left Control key |
R_CTRL |
Right Control key |
L_GUI |
Left Windows key |
R_GUI |
Right Windows key |
INS |
Insert key |
DEL |
Delete key |
HOME |
Home key |
END |
End key |
PG_UP |
Page Up key |
PG_DN |
Page Down key |
ENTER |
Enter key |
TAB |
Tab key |
BREAK |
Break key |
BACKSPACE |
Backspace key |
NUM_PLUS |
Num Plus key |
NUM_MINUS |
Num Minus key |
SCRL_LCK |
Scroll Lock key |
SYS_RQ |
Sys Rq key |
PRINT_SCRN |
|
F1 |
F1 key |
F2 |
F2 key |
F3 |
F3 key |
F4 |
F4 key |
F5 |
F5 key |
F6 |
F6 key |
F7 |
F7 key |
F8 |
F8 key |
F9 |
F9 key |
F10 |
F10 key |
F11 |
F11 key |
F12 |
F12 key |
SPACE |
Space key |
' |
Apostrophe key |
, |
Comma key |
- |
Hyphen key |
. |
Period key |
/ |
Slash key |
; |
Semicolon key |
= |
Equals key |
[ |
Left square bracket key |
\ |
Backslash key |
] |
Right square bracket key |
“”“` | Backtick key |
0 |
0 key |
1 |
1 key |
2 |
2 key |
3 |
3 key |
4 |
4 key |
5 |
5 key |
6 |
6 key |
7 |
7 key |
8 |
8 key |
9 |
9 key |
a |
a key |
b |
b key |
c |
c key |
d |
d key |
e |
e key |
f |
f key |
g |
g key |
h |
h key |
i |
i key |
j |
j key |
k |
k key |
l |
l key |
m |
m key |
n |
n key |
o |
o key |
p |
p key |
q |
q key |
r |
r key |
s |
s key |
t |
t key |
u |
u key |
v |
v key |
w |
w key |
x |
x key |
y |
y key |
z |
z key |
Oem.Hpe.IntegratedRemoteConsole.LockKey
Oem.Hpe.IntegratedRemoteConsole.LockKey.CustomKeySequence (array)
Member of Manager.v1_5_1.Manager
CustomKeySequence
is an array containing elements of:
CustomKeySequence[{item}] Member of Manager.v1_5_1.Manager
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NONE |
No key |
ESC |
Escape key |
L_ALT |
Left Alt key |
R_ALT |
Right Alt key |
L_SHIFT |
Left Shift key |
R_SHIFT |
Right Shift key |
L_CTRL |
Left Control key |
R_CTRL |
Right Control key |
L_GUI |
Left Windows key |
R_GUI |
Right Windows key |
INS |
Insert key |
DEL |
Delete key |
HOME |
Home key |
END |
End key |
PG_UP |
Page Up key |
PG_DN |
Page Down key |
ENTER |
Enter key |
TAB |
Tab key |
BREAK |
Break key |
BACKSPACE |
Backspace key |
NUM_PLUS |
Num Plus key |
NUM_MINUS |
Num Minus key |
SCRL_LCK |
Scroll Lock key |
SYS_RQ |
Sys Rq key |
PRINT_SCRN |
|
F1 |
F1 key |
F2 |
F2 key |
F3 |
F3 key |
F4 |
F4 key |
F5 |
F5 key |
F6 |
F6 key |
F7 |
F7 key |
F8 |
F8 key |
F9 |
F9 key |
F10 |
F10 key |
F11 |
F11 key |
F12 |
F12 key |
SPACE |
Space key |
' |
Apostrophe key |
, |
Comma key |
- |
Hyphen key |
. |
Period key |
/ |
Slash key |
; |
Semicolon key |
= |
Equals key |
[ |
Left square bracket key |
\ |
Backslash key |
] |
Right square bracket key |
”“”` | Backtick key |
0 |
0 key |
1 |
1 key |
2 |
2 key |
3 |
3 key |
4 |
4 key |
5 |
5 key |
6 |
6 key |
7 |
7 key |
8 |
8 key |
9 |
9 key |
a |
a key |
b |
b key |
c |
c key |
d |
d key |
e |
e key |
f |
f key |
g |
g key |
h |
h key |
i |
i key |
j |
j key |
k |
k key |
l |
l key |
m |
m key |
n |
n key |
o |
o key |
p |
p key |
q |
q key |
r |
r key |
s |
s key |
t |
t key |
u |
u key |
v |
v key |
w |
w key |
x |
x key |
y |
y key |
z |
z key |
Oem.Hpe.IntegratedRemoteConsole.LockKey.LockOption Member of Manager.v1_5_1.Manager
Description | Lock option setting. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Windows |
This option configures iLO to lock a managed server running a Windows operating system. |
Custom |
This option configures iLO to use a custom key sequence to lock a managed server or log out a user on that server. |
Disabled |
This option disables the Remote Console Computer Lock feature. |
Oem.Hpe.IntegratedRemoteConsole.TrustedCertificateRequired Member of Manager.v1_5_1.Manager
Description | When this setting is enabled and a trusted SSL certificate has been imported into iLO, the .NET IRC is launched by using an HTTPS connection. When this setting is disabled, the .NET IRC is launched by using a non-SSL connection. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.License
Oem.Hpe.License.LicenseKey Member of Manager.v1_5_1.Manager
Description | The installed license key. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.License.LicenseString Member of Manager.v1_5_1.Manager
Description | Describes the type of license installed on management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.License.LicenseType Member of Manager.v1_5_1.Manager
Description | Indicates whether the license is Perpetual or Evaluation. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PersistentMouseKeyboardEnabled
Member of Manager.v1_5_1.Manager
Description | Persistent mouse and keyboard feature is enabled or not. When this feature is enabled, the iLO virtual mouse and keyboard are always connected to the iLO UHCI USB controller. When this feature is disabled, the iLO virtual mouse and keyboard are connected dynamically to the iLO UHCI controller only when a Remote Console application is open and connected to iLO. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.PhysicalMonitorHealthStatusEnabled
Member of Manager.v1_5_1.Manager
Description | This property enables or disables the display of Server Health Status on a physical monitor attached to the system. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.RIBCLEnabled
Member of Manager.v1_5_1.Manager
Description | This property enables or disables RIBCL for the management processor. The management processor will require reset when this field is modified. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.RemoteConsoleThumbnailEnabled
Member of Manager.v1_5_1.Manager
Description | This property enables or disables the accessibility of remote console thumbnail image in iLO. Disabling this property will not disable remote console feature. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.RequireHostAuthentication
Member of Manager.v1_5_1.Manager
Description | Determines whether authentication is required for host-based utilities which use CHIF (typically use of CHIF requires Administrator/root credentials) |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.RequiredLoginForiLORBSU
Member of Manager.v1_5_1.Manager
Description | Determines whether a user-credential prompt is displayed when a user accesses the iLO RBSU or the iLO Configuration Utility. The following settings are valid: Enabled-A login dialog box opens when a user accesses the iLO RBSU or the iLO Configuration Utility. Disabled (default)-No login is required when a user accesses the iLO RBSU or the iLO Configuration Utility. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.SerialCLISpeed
Member of Manager.v1_5_1.Manager
Description | Serial command line interface speed in bits/second. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
9600 |
19200 |
38400 |
57600 |
115200 |
Oem.Hpe.SerialCLIStatus
Member of Manager.v1_5_1.Manager
Description | Status of serial command line interface. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Disabled |
Serial command line interface is disabled. |
EnabledNoAuth |
Serial command line interface is enabled with no authentication required. |
EnabledAuthReq |
Serial command line interface is enabled with authentication required. |
Oem.Hpe.SerialCLIUART
Member of Manager.v1_5_1.Manager
Description | Indicates presence of UART hardware. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NotPresent |
UART hardware present. |
Present |
UART hardware not present. |
Oem.Hpe.VSPDlLoggingEnabled
Member of Manager.v1_5_1.Manager
Description | This property enables or disables logging to the downloadable Virtual Serial Port (VSP) log. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.VSPLogDownloadEnabled
Member of Manager.v1_5_1.Manager
Description | This property enables or disables download of the downloadable Virtual Serial Port (VSP) log. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.VideoPresenceDetectOverride
Member of Manager.v1_5_1.Manager
Description | This property controls video presence detection on the VGA port. True: firmware workaround detects some KVMs that are not automatically supported. False: hardware-based automatic video presence detection. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.VideoPresenceDetectOverrideSupported
Member of Manager.v1_5_1.Manager
Description | This indicates whether the VideoPresenceDetectOverride property is supported on this type of system. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.VirtualNICEnabled
Member of Manager.v1_5_1.Manager
Description | Indicates whether the Virtual Network Interface is enabled or not. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.WebGuiEnabled
Member of Manager.v1_5_1.Manager
Description | This property enables or disables WEB GUI access for the management processor. The management processor will require reset when this field is modified. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.iLOFunctionalityEnabled
Member of Manager.v1_5_1.Manager
Description | iLO functionality is enabled on this platform. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.iLOFunctionalityRequired
Member of Manager.v1_5_1.Manager
Description | iLO functionality is required and can’t be disabled on this platform (usually blades). |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.iLOIPduringPOSTEnabled
Member of Manager.v1_5_1.Manager
Description | Specifies whether displaying the iLO network IP address during host server POST is enabled(default) or not. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.iLORBSUEnabled
Member of Manager.v1_5_1.Manager
Description | Enables or disables the iLO Configuration Utility. The following settings are valid: Enabled (default)-On servers that support the iLO Configuration Utility, the iLO Configuration Utility is available when you access the UEFI System Utilities by pressing F9 during POST. Disabled-On servers that support the iLO Configuration Utility, the iLO Configuration Utility is not available when you access the UEFI System Utilities by pressing F9 during POST. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.iLOSelfTestResults (array)
Member of Manager.v1_5_1.Manager
iLOSelfTestResults
is an array containing elements of:
iLOSelfTestResults[{item}].Notes Member of Manager.v1_5_1.Manager
Description | Additional Information (if any) about the Self Test. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
iLOSelfTestResults[{item}].SelfTestName Member of Manager.v1_5_1.Manager
Description | iLO Self Test Name. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
UnknownSelfTest |
UnknownSelfTest self test result. |
CryptographicHardware |
CryptographicHardware self test result. |
Memory |
Memory self test result. |
WebServerCryptography |
WebServerCryptography self test result. |
MiscCryptography |
MiscCryptography self test result. |
UART |
UART self test result. |
HoodSense |
Hood Sense self test result. |
NVRAMInterface |
NVRAMInterface self test result. |
NVRAMData |
NVRAMData self test result. |
NVRAMSpace |
NVRAM space self test result. |
NIC |
NIC self test result. |
EmbeddedFlash |
EmbeddedFlash or SD Card self test result. |
StaticRAM |
StaticRAM self test result. |
EEPROM |
EEPROM self test result. |
I2C |
I2C self test result. |
BootBlock |
BootBlock self test result. |
ThreadInit |
ThreadInit self test result. |
Infrastructure |
Infrastructure self test result. |
HostRom |
|
SupportedHost |
Supported Host self test result. |
EEPROMContent |
EEPROMContent self test result. |
PowerManagementController |
Power Management Controller self test result. |
CPLDPAL0 |
CPLD PAL0 self test result. |
CPLDPAL1 |
CPLD PAL1 self test result. |
CPLDPAL2 |
CPLD PAL2 self test result. |
CPLDPAL3 |
CPLD PAL3 self test result. |
CPLDPAL4 |
CPLD PAL4 self test result. |
CPLDPAL5 |
CPLD PAL5 self test result. |
ASICFuses |
ASIC Fuses self test result. |
SecureElement |
Secure Element self test result. |
iLOSelfTestResults[{item}].Status Member of Manager.v1_5_1.Manager See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.iLOServicePort
Oem.Hpe.iLOServicePort.MassStorageAuthenticationRequired Member of Manager.v1_5_1.Manager
Description | Indicates whether mass storage authentication is required or not. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.iLOServicePort.USBEthernetAdaptersEnabled Member of Manager.v1_5_1.Manager
Description | Indicates whether the USB Ethernet Adapters are enabled or not. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.iLOServicePort.USBFlashDriveEnabled Member of Manager.v1_5_1.Manager
Description | Indicates whether the USB Flash Drive is enabled or not. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.iLOServicePort.iLOServicePortEnabled Member of Manager.v1_5_1.Manager
Description | Indicates whether the iLO Service Port is enabled or not. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Redundancy
Member of Manager.v1_5_1.Manager See the Redfish standard schema and specification for information on common Redundancy object.
SerialConsole
SerialConsole.ConnectTypesSupported (array)
Member of Manager.v1_5_1.Manager
ConnectTypesSupported
is an array containing elements of:
ConnectTypesSupported[{item}] Member of Manager.v1_5_1.Manager
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
SSH |
The controller supports a Serial Console connection using the SSH protocol |
Telnet |
The controller supports a Serial Console connection using the Telnet protocol |
IPMI |
The controller supports a Serial Console connection using the IPMI Serial-over-LAN (SOL) protocol |
Oem |
SerialConsole.MaxConcurrentSessions Member of Manager.v1_5_1.Manager
Description | This is the maximum number of Serial Console sessions, regardless of protocol, that this manager supports. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
SerialConsole.ServiceEnabled Member of Manager.v1_5_1.Manager
Description | Indicates if the Command Shell service is enabled for this manager. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SerialInterfaces
The link to a collection of serial interfaces that this manager uses for serial and console communication.
SerialInterfaces is a link ("@odata.id": URI
) to another resource.
Status
Member of Manager.v1_5_1.Manager See the Redfish standard schema and specification for information on common Status object.
UUID
Member of Manager.v1_5_1.Manager
Description | This is a universally unique identifier that supervisory software uses to uniquely identify this manager. The UUID is assigned when the system is manufactured. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
VirtualMedia
This is a reference to the virtual media services for this manager.
VirtualMedia is a link ("@odata.id": URI
) to another resource.
Actions
Manager.Reset Member of Manager.v1_5_1.Manager
Parameters:
ResetType (string)
Value | Description |
---|---|
ForceRestart | |
GracefulRestart |
HpeiLO.ClearRestApiState Member of Manager.v1_5_1.Manager Clears the persistent state of the REST API. Some portions of the API may not be available until after the server reboots.
There are no parameters for this action.
HpeiLO.ClearHotKeys Member of Manager.v1_5_1.Manager Clear hot keys which are used during Remote Console sessions.
There are no parameters for this action.
HpeiLO.ResetToFactoryDefaults Member of Manager.v1_5_1.Manager Resets the iLO to Factory Defaults.
Parameters:
ResetType (string)
Value | Description |
---|---|
Default | Reset iLO to defaults, clear logs and reboot iLO. |
HpeiLO.DisableiLOFunctionality Member of Manager.v1_5_1.Manager This action will disable the iLO network and will terminate communications with operating system drivers. To re-enable iLO functionality, use the iLO Configuration Utility (in the UEFI System Utilities) to set iLO Functionality to Enabled. For more information see the HPE UEFI System Utilities User Guide. The action resets/reboots the manager. iLO functionality cannot be disabled on server blades.
There are no parameters for this action.
HpeiLO.ClearNVRAM Member of Manager.v1_5_1.Manager Delete the files from NVRAM CFG area.
There are no parameters for this action.
HpeiLO.EnableCloudConnect Member of Manager.v1_5_1.Manager Action to enable cloud connect service.
Parameters:
ActivationKey (string)
The activation key is the customer account ID of HPE GreenLake. Obtain the account ID by visiting HPE GreenLake portal-Manage->Account Details card.
OverrideManager (boolean)
The property is used to override the existing manager (Example: HPE OneView).
HpeiLO.RequestFirmwareAndOsRecovery Member of Manager.v1_5_1.Manager Requests that the Recovery Install set be invoked, and when complete causes a OS reinstallation.
There are no parameters for this action.
HpeiLO.DisableCloudConnect Member of Manager.v1_5_1.Manager Action to disable cloud connect service.
Parameters:
FailReason (string)
Indicates the reason for cloud connection failure.
Value | Description |
---|---|
iLOTimeError | Indicates the cloud activation failed due to incorrect iLO time. |
ProxyError | Indicates the cloud activation failed due to Proxy errors. |
ActivationKeyMissing | Indicates the cloud activation failed due to missing activation key. |
NetworkError | Indicates the cloud activation failed due to network issues. |
WrongiLOVersion | Indicates the cloud activation failed due to wrong iLO version errors. |
WrongActivationKey | Indicates the cloud activation failed due to wrong activation key errors. |
ManagerAccount.v1_3_0.ManagerAccount
@odata.type: "#ManagerAccount.v1_3_0.ManagerAccount"
The user accounts, owned by a Manager, are defined in this resource. Changes to a Manager Account may affect the current Redfish service connection if this manager is responsible for the Redfish service.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/accounts/{item} |
GET PATCH DELETE |
Oem.Hpe.LoginName
Member of ManagerAccount.v1_3_0.ManagerAccount
Description | Descriptive login name that helps to easily identify the owner of each user name. The login name does not have to be the same as the user name and must use printable characters. The maximum length for a user name is 39 characters. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.Privileges
Oem.Hpe.Privileges.HostBIOSConfigPriv Member of ManagerAccount.v1_3_0.ManagerAccount
Description | This privilege enables a user to configure Host Bios Settings. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.HostNICConfigPriv Member of ManagerAccount.v1_3_0.ManagerAccount
Description | This privilege enables a user to configure Host NIC Settings. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.HostStorageConfigPriv Member of ManagerAccount.v1_3_0.ManagerAccount
Description | This privilege enables a user to configure Host Storage Settings. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.LoginPriv Member of ManagerAccount.v1_3_0.ManagerAccount
Description | This privilege enables a user to log in to management processor. All local accounts have the login privilege. This privilege is added automatically if it is not specified. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.RemoteConsolePriv Member of ManagerAccount.v1_3_0.ManagerAccount
Description | This privilege enables a user to remotely access the host system Remote Console, including video, keyboard, and mouse control. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.SystemRecoveryConfigPriv Member of ManagerAccount.v1_3_0.ManagerAccount
Description | This privilege enables a user to manage the critical recovery firmware images on the iLO Repository. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.UserConfigPriv Member of ManagerAccount.v1_3_0.ManagerAccount
Description | This privilege enables a user to add, edit, and delete local management processor user accounts. A user with this privilege can change privileges for all users. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.VirtualMediaPriv Member of ManagerAccount.v1_3_0.ManagerAccount
Description | This privilege enables a user to use the Virtual Media feature on the host system. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.VirtualPowerAndResetPriv Member of ManagerAccount.v1_3_0.ManagerAccount
Description | This privilege enables a user to power-cycle or reset the host system. These activities interrupt system availability. A user with this privilege can diagnose the system by using the Generate NMI to System button. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.iLOConfigPriv Member of ManagerAccount.v1_3_0.ManagerAccount
Description | This privilege enables a user to configure most management processor settings, including security settings, and to remotely update the management processor firmware. This privilege does not enable local user account administration. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.ServiceAccount
Member of ManagerAccount.v1_3_0.ManagerAccount
Description | Indicate that the account type is service account |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.SkipEscCharsCheck
Member of ManagerAccount.v1_3_0.ManagerAccount
Description | Indicates that the escape characters check to be skipped or not |
Type | boolean |
Read Only | False |
Added | iLO6 1.40 |
Password
Member of ManagerAccount.v1_3_0.ManagerAccount
Description | The password used to log in to the management processor. The maximum length for a password is 39 characters. The minimum length for a password is specified in the MinPasswordLength property of the AccountService schema. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
PasswordChangeRequired
Member of ManagerAccount.v1_3_0.ManagerAccount
Description | Indicates that the password for this account must be changed. The service requires the password to be changed before access is allowed. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
RoleId
Member of ManagerAccount.v1_3_0.ManagerAccount
Description | This property contains the name of the Role for this account. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
UserName
Member of ManagerAccount.v1_3_0.ManagerAccount
Description | The name used to log in to the management processor. The user name does not have to be the same as the login name. The maximum length for the user name is 39 characters. The user name must use printable characters. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
ManagerAccountCollection.ManagerAccountCollection
@odata.type: "#ManagerAccountCollection.ManagerAccountCollection"
A Collection of ManagerAccount resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/accounts |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
ManagerAccount |
Members (array)
Member of ManagerAccountCollection.ManagerAccountCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of ManagerAccountCollection.ManagerAccountCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of ManagerAccountCollection.ManagerAccountCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
ManagerCollection.ManagerCollection
@odata.type: "#ManagerCollection.ManagerCollection"
A Collection of Manager resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Manager |
Members (array)
Member of ManagerCollection.ManagerCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of ManagerCollection.ManagerCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of ManagerCollection.ManagerCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
@odata.type: "#ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol"
This resource is used to obtain or modify the network services managed by this manager.
Granularity to enable/disable HTTP(S) ports
iLO 6 supports enabling/disabling the HTTP/HTTPS ports.
Disable/Enable HTTP(S) Port:
- The HTTP port can be disabled by setting the
"Port"
property to value 0. Similarly, it can be enabled by setting it to a valid port value like 80. - This has been decoupled from the HTTPS port enable/disable status.
NOTE:
ProtocolEnabled
property under HTTP object is not related to HTTP alone. It is related to the whole webserver. Hence the ProtocolEnabled
property will remain true
unless the whole webserver is disabled.
For example, to disable HTTP port:
PATCH /redfish/v1/Managers/1/NetworkProtocol
PATCH Payload:
{
"HTTP": {
"Port": 0
}
}
NOTE:
iLO reset is required after the PATCH for the change to come into effect.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/networkprotocol |
GET POST PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Oem/Hpe/Links/SNMPService |
HpeiLOSnmpService |
Oem/Hpe/Links/EthernetInterfaces |
Collection of EthernetInterface |
FQDN
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The fully-qualified domain name of the manager that is obtained by DNS and includes the host name and top-level domain name. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
HTTP
HTTP.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The HTTP port number. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
HTTP.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether HTTP is enabled or disabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
HTTPS
HTTPS.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The HTTPS/SSL port number. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
HTTPS.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether HTTPS/SSL is enabled or disabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
HostName
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The host name of the manager that is obtained by DNS and does not include any domain information. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
IPMI
IPMI.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The IPMI over LAN port number. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
IPMI.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether IPMI over LAN is enabled for the manager. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
KVMIP
KVMIP.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The KVM-IP port number. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
KVMIP.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether KVM-IP is enabled for the manager. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.AlertMailEmail
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The destination email address for email alerts. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.AlertMailEnabled
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether AlertMail is enabled. This can be enabled only when the properties AlertMailEmail, AlertMailSenderDomain and AlertMailSMTPServer are set or not empty. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.AlertMailSMTPAuthEnabled
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether AlertMail SMTP Authentication is enabled. This can be enabled only when the properties AlertMailSMTPSecureEnabled, AlertMailSMTPAuthUser and AlertMailSMTPAuthPw are set or not empty. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.AlertMailSMTPAuthPw
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The password credential for SMTP server Authentication. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.AlertMailSMTPAuthUser
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The username credential for SMTP server Authentication. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.AlertMailSMTPPort
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The SMTP server port number. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.AlertMailSMTPSecureEnabled
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether AlertMail SMTP Secure Connection (SSL/TLS) is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.AlertMailSMTPServer
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The IP address or DNS name of the SMTP server or the Mail Submission Agent (MSA). |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.AlertMailSenderDomain
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The domain name for the sender email address. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.ConfigurationSettings
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | State of the currently displayed configuration settings. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Current |
SomePendingReset |
Oem.Hpe.EnhancedDownloadPerformanceEnabled
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether enhanced download for virtual media and firmware update is enabled or disabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.FederationEnabled
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether management processor federation management is enabled or disabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.FederationSupported
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether management processor federation is supported. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.IEEE_8021X_Support
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether 802.1X feature is enabled or not. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.KcsEnabled
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether KCS interface is enabled or disabled for the BMC. |
Type | boolean |
Read Only | False |
Added | iLO6 1.40 |
Oem.Hpe.RemoteSyslogEnabled
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether Remote Syslog is enabled. When enabled, management processor sends notification messages to the specified Syslog server. This can be enabled only when the property RemoteSyslogServer is set or not empty. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.RemoteSyslogPort
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The port number through which the Syslog servers are listening. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.RemoteSyslogServer
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The IP address, FQDN, IPv6 name, or short name of the servers running the Syslog service. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.SMTPForTFAEnabled
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether SMTP for Two Factor Authentication is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.50 |
Oem.Hpe.SNMPTrapPort
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The SNMP trap port number. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.SerialOverLanLogging
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether Serial Over LAN (SOL) or Virtual Serial Port (VSP) logging is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.VirtualMediaEncryptionEnabled
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Enables or disables encryption on virtual media connections. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.WebProxyConfiguration
Oem.Hpe.WebProxyConfiguration.ProxyPassword Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates the proxy password (optional) |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.WebProxyConfiguration.ProxyPort Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates the proxy port. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.WebProxyConfiguration.ProxyServer Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates the hostname or IP address of proxy server. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.WebProxyConfiguration.ProxyUserName Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates the proxy username (optional) |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.XMLResponseEnabled
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Determines whether management processor responds to anonymous XML discovery requests. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
SNMP
SNMP.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The SNMP port number. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
SNMP.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether SNMP is enabled for the manager. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
SSDP
SSDP.NotifyIPv6Scope Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The scope for IPv6 Notify messages for SSDP. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Link |
SSDP Notify messages are sent to addresses in the IPv6 Local Link scope |
Site |
SSDP Notify messages are sent to addresses in the IPv6 Local Site scope. |
Organization |
SSDP Notify messages are sent to addresses in the IPv6 Local Organization scope. |
SSDP.NotifyMulticastIntervalSeconds Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates how often multicast is performed for SSDP. Allowed values are 0, 30, 60, 120, 300, 600, 900 or 1800. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
SSDP.NotifyTTL Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The Time to Live (TTL) hop count for SSDP Notify messages. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
SSDP.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The SSDP port number. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
SSDP.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether SSDP is enabled for the manager. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
SSH
SSH.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The SSH port number. NOTE: When this field is modified, the Manager will reset automatically. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
SSH.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether SSH is enabled for the manager. NOTE: When this field is modified, the Manager will reset automatically. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Status
Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol See the Redfish standard schema and specification for information on common Status object.
VirtualMedia
VirtualMedia.Port Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | The Virtual Media port number. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
VirtualMedia.ProtocolEnabled Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol
Description | Indicates whether Virtual Media is enabled for the manager. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Actions
HpeiLOManagerNetworkService.SendTestAlertMail Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol There are no parameters for this action.
HpeiLOManagerNetworkService.SendTestSyslog Member of ManagerNetworkProtocol.v1_0_0.ManagerNetworkProtocol There are no parameters for this action.
Memory.v1_14_0.Memory
@odata.type: "#Memory.v1_14_0.Memory"
The Memory resource describes a memory module.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memory/{item} |
GET |
AllocationAlignmentMiB
Member of Memory.v1_14_0.Memory
Description | The boundary which memory regions are allocated on, measured in MiB. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
AllocationIncrementMiB
Member of Memory.v1_14_0.Memory
Description | The size of the smallest unit of allocation for a memory region, thus it is the multiple in which regions are actually reserved. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
BaseModuleType
Member of Memory.v1_14_0.Memory
Description | The base module type of the memory. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
RDIMM |
Registered DIMM |
UDIMM |
UDIMM |
SO_DIMM |
SO_DIMM |
LRDIMM |
Load Reduced |
Mini_RDIMM |
Mini_RDIMM |
Mini_UDIMM |
Mini_UDIMM |
SO_RDIMM_72b |
SO_RDIMM_72b |
SO_UDIMM_72b |
SO_UDIMM_72b |
SO_DIMM_16b |
SO_DIMM_16b |
SO_DIMM_32b |
SO_DIMM_32b |
Die |
A die within a package. |
BusWidthBits
Member of Memory.v1_14_0.Memory
Description | Bus Width in bits. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
CacheSizeMiB
Member of Memory.v1_14_0.Memory
Description | Total size of the cache portion memory in MiB. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
CapacityMiB
Member of Memory.v1_14_0.Memory
Description | Memory Capacity in MiB. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
ConfigurationLocked
Member of Memory.v1_14_0.Memory
Description | Indicates that the configuration of this memory has been locked |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
DataWidthBits
Member of Memory.v1_14_0.Memory
Description | Data Width in bits. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
DeviceID
Member of Memory.v1_14_0.Memory
Description | Device ID |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
DeviceLocator
Member of Memory.v1_14_0.Memory
Description | Location of the Memory in the platform |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ErrorCorrection
Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NoECC |
No ECC available |
SingleBitECC |
Single bit Data error can be corrected by ECC |
MultiBitECC |
Multi-bit Data errors can be corrected by ECC |
AddressParity |
Address Parity errors can be corrected |
FirmwareApiVersion
Member of Memory.v1_14_0.Memory
Description | Version of API supported by the firmware |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
FirmwareRevision
Member of Memory.v1_14_0.Memory
Description | The firmware revision of this device |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
LogicalSizeMiB
Member of Memory.v1_14_0.Memory
Description | Total size of the logical memory in MiB. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Manufacturer
Member of Memory.v1_14_0.Memory
Description | The Memory manufacturer |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryDeviceType
Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
DDR |
DDR |
DDR2 |
DDR2 |
DDR3 |
DDR3 |
DDR4 |
DDR4 |
DDR4_SDRAM |
DDR4 SDRAM |
DDR4E_SDRAM |
DDR4E SDRAM |
LPDDR4_SDRAM |
LPDDR4 SDRAM |
DDR3_SDRAM |
DDR3 SDRAM |
LPDDR3_SDRAM |
LPDDR3 SDRAM |
DDR2_SDRAM |
DDR2 SDRAM |
DDR2_SDRAM_FB_DIMM |
DDR2 SDRAM FB_DIMM |
DDR2_SDRAM_FB_DIMM_PROBE |
DDR2 SDRAM FB_DIMM PROBE |
DDR_SGRAM |
DDR SGRAM |
DDR_SDRAM |
DDR SDRAM |
ROM |
ROM |
SDRAM |
SDRAM |
EDO |
EDO |
FastPageMode |
Fast Page Mode |
PipelinedNibble |
Pipelined Nibble |
Logical |
Logical Non-volatile device. |
DDR5 |
DDR5 |
MemoryLocation
MemoryLocation.Channel Member of Memory.v1_14_0.Memory
Description | Channel number in which Memory is connected |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryLocation.MemoryController Member of Memory.v1_14_0.Memory
Description | Memory controller number in which Memory is connected |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryLocation.Slot Member of Memory.v1_14_0.Memory
Description | Slot number in which Memory is connected |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryLocation.Socket Member of Memory.v1_14_0.Memory
Description | Socket number in which Memory is connected |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryMedia (array)
Member of Memory.v1_14_0.Memory
MemoryMedia
is an array containing elements of:
MemoryMedia[{item}] Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
DRAM |
DRAM media |
NAND |
NAND media |
Intel3DXPoint |
Intel 3D XPoint media |
Proprietary |
Proprietary media |
MemorySubsystemControllerManufacturerID
Member of Memory.v1_14_0.Memory
Description | The manufacturer ID of the memory subsystem controller of this memory module. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MemorySubsystemControllerProductID
Member of Memory.v1_14_0.Memory
Description | The product ID of the memory subsystem controller of this memory module. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryType
Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
DRAM |
DRAM |
NVDIMM_N |
NVDIMM_N as defined by JEDEC. |
NVDIMM_F |
NVDIMM_F as defined by JEDEC. |
NVDIMM_P |
NVDIMM_P as defined by JEDEC. |
IntelOptane |
The memory module is Intel Optane DC Persistent Memory and composed of a combination of non-volatile and volatile memory. |
ModuleManufacturerID
Member of Memory.v1_14_0.Memory
Description | The manufacturer ID of this memory module. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ModuleProductID
Member of Memory.v1_14_0.Memory
Description | The product ID of this memory module. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
NonVolatileSizeMiB
Member of Memory.v1_14_0.Memory
Description | Total size of the non-volatile portion memory in MiB. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Armed
Member of Memory.v1_14_0.Memory
Description | Specifies the current backup-ready status of the NVDIMM_N if available. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Attributes (array)
Member of Memory.v1_14_0.Memory
Attributes
is an array containing elements of:
Attributes[{item}] Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
HpeSmartMemory |
This DIMM is HPE Smart Memory |
HpeStandardMemory |
This DIMM is HPE Standard Memory |
HpeLogicalNVDIMM |
This DIMM is HPE Logical Memory. |
Oem.Hpe.BaseModuleType
Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
BurstEDO |
FastPage |
Synchronous |
EDO |
LRDIMM |
RDRAM |
RDIMM |
UDIMM |
NVDIMM |
NVDIMM-N |
LRNVDIMM |
SO_RDIMM_72b |
SO_UDIMM_72b |
PMM |
Oem.Hpe.BlocksRead
Member of Memory.v1_14_0.Memory
Description | Number of blocks read for the lifetime of the Memory. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.BlocksWritten
Member of Memory.v1_14_0.Memory
Description | Number of blocks written for the lifetime of the Memory. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DIMMManufacturingDate
Member of Memory.v1_14_0.Memory
Description | Module manufacturing date in YYWW format. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DIMMStatus
Member of Memory.v1_14_0.Memory
Description | Specifies memory module status and whether the module in use. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The status of the DIMM is unknown. |
Other |
DIMM status that does not fit any of these definitions. |
NotPresent |
DIMM is not present. |
PresentUnused |
DIMM is present but unused. |
GoodInUse |
DIMM is functioning properly and currently in use. |
AddedButUnused |
DIMM is added but currently unused. |
UpgradedButUnused |
DIMM is upgraded but currently unused. |
ExpectedButMissing |
DIMM is expected but missing. |
DoesNotMatch |
DIMM type does not match. |
NotSupported |
DIMM is not supported. |
ConfigurationError |
Configuration error in DIMM. |
Degraded |
DIMM state is degraded. |
PresentSpare |
DIMM is present but used as spare. |
GoodPartiallyInUse |
DIMM is functioning properly but partially in use. |
MapOutConfiguration |
DIMM mapped out due to configuration error. |
MapOutError |
DIMM mapped out due to training failure. |
Oem.Hpe.MaxOperatingSpeedMTs
Member of Memory.v1_14_0.Memory
Description | Maximum capable speed of the device, in megatransfers per second (MT/s). |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.MinimumVoltageVoltsX10
Member of Memory.v1_14_0.Memory
Description | The minimum DIMM voltage multiplied by 10, for example, 1.2v = 12. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PartNumber
Member of Memory.v1_14_0.Memory
Description | The HPE product part number of this device |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PredictedMediaLifeLeftPercent
Member of Memory.v1_14_0.Memory
Description | The percentage of media life left. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ProductName
Member of Memory.v1_14_0.Memory
Description | friendly product name from SMBIOS 202 record |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.RelatedBackupStores (array)
Member of Memory.v1_14_0.Memory
RelatedBackupStores
is an array containing elements of:
RelatedBackupStores[{item}].@odata.id Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Oem.Hpe.RelatedPhysicalDIMMs (array)
Member of Memory.v1_14_0.Memory
RelatedPhysicalDIMMs
is an array containing elements of:
RelatedPhysicalDIMMs[{item}].@odata.id Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Oem.Hpe.RelatedPowerBackupUnitBays (array)
Member of Memory.v1_14_0.Memory
RelatedPowerBackupUnitBays
is an array containing elements of:
RelatedPowerBackupUnitBays[{item}] Member of Memory.v1_14_0.Memory
Description | Battery backup unit bay number. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SPDBytes (array)
Member of Memory.v1_14_0.Memory
SPDBytes
is an array containing elements of:
SPDBytes[{item}] Member of Memory.v1_14_0.Memory
Description | The SPD Bytes in the DIMM |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SpareBlockLeftPercent
Member of Memory.v1_14_0.Memory
Description | The percentage of the number of spare blocks remaining. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.VendorName
Member of Memory.v1_14_0.Memory
Description | Vendor Name decoded from VendorID |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
OperatingMemoryModes (array)
Member of Memory.v1_14_0.Memory
OperatingMemoryModes
is an array containing elements of:
OperatingMemoryModes[{item}] Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Volatile |
Volatile memory |
PMEM |
Persistent memory, byte accesible through system address space |
Block |
Block accessible system memory |
OperatingSpeedMhz
Member of Memory.v1_14_0.Memory
Description | Operating speed of Memory in MHz |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
PartNumber
Member of Memory.v1_14_0.Memory
Description | The product part number of this device |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PersistentRegionNumberLimit
Member of Memory.v1_14_0.Memory
Description | Total number of persistent regions this Memory can support. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
PersistentRegionSizeLimitMiB
Member of Memory.v1_14_0.Memory
Description | Total size of persistent regions in MiB |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
PersistentRegionSizeMaxMiB
Member of Memory.v1_14_0.Memory
Description | Maximum size of a single persistent region in MiB. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
RankCount
Member of Memory.v1_14_0.Memory
Description | Number of ranks available in the Memory |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Regions (array)
Member of Memory.v1_14_0.Memory
Regions
is an array containing elements of:
Regions[{item}].MemoryClassification Member of Memory.v1_14_0.Memory
Description | Classification of memory occupied by the given memory region |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Volatile |
Volatile memory |
ByteAccessiblePersistent |
Byte accessible persistent memory |
Block |
Block accesible memory |
Regions[{item}].PassphraseEnabled Member of Memory.v1_14_0.Memory
Description | State of the passphrase for this region |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Regions[{item}].RegionId Member of Memory.v1_14_0.Memory
Description | Unique region ID representing a specific region within the Memory |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Regions[{item}].SizeMiB Member of Memory.v1_14_0.Memory
Description | Size of this memory region in MiB |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
SecurityCapabilities
SecurityCapabilities.ConfigurationLockCapable Member of Memory.v1_14_0.Memory
Description | Support for configuration locking |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
SecurityCapabilities.DataLockCapable Member of Memory.v1_14_0.Memory
Description | Support for data locking |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
SecurityCapabilities.PassphraseCapable Member of Memory.v1_14_0.Memory
Description | Memory passphrase set capability |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
SecurityCapabilities.PassphraseLockLimit Member of Memory.v1_14_0.Memory
Description | Maximum number of incorrect passphrase attempts allowed before memory is locked. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
SecurityState
Member of Memory.v1_14_0.Memory
Description | The current security state of this Memory |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Secure mode is enabled and access to the data is unlocked |
Disabled |
Secure mode is disabled |
Locked |
Secure mode is enabled and access to the data is locked |
Passphraselimit |
Number of attempts to unlock the Memory exceeded limit |
SerialNumber
Member of Memory.v1_14_0.Memory
Description | The serial number of this device |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of Memory.v1_14_0.Memory See the Redfish standard schema and specification for information on common Status object.
SubsystemDeviceID
Member of Memory.v1_14_0.Memory
Description | Subsystem Device ID |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SubsystemVendorID
Member of Memory.v1_14_0.Memory
Description | SubSystem Vendor ID |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
VendorID
Member of Memory.v1_14_0.Memory
Description | Vendor ID |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
VolatileRegionNumberLimit
Member of Memory.v1_14_0.Memory
Description | Total number of volatile regions this Memory can support. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
VolatileRegionSizeLimitMiB
Member of Memory.v1_14_0.Memory
Description | Total size of volatile regions in MiB |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
VolatileRegionSizeMaxMiB
Member of Memory.v1_14_0.Memory
Description | Maximum size of a single volatile region in MiB. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
VolatileSizeMiB
Member of Memory.v1_14_0.Memory
Description | Total size of the volitile portion memory in MiB. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryChunks.v1_2_3.MemoryChunks
@odata.type: "#MemoryChunks.v1_2_3.MemoryChunks"
The MemoryChunks resource describes a Memory Chunk and its configuration.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memorydomains/{item}/memorychunks/{item} |
GET DELETE |
AddressRangeType
Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Memory type of this memory chunk |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
PMEM |
Byte accessible persistent memory |
InterleaveSets (array)
Member of MemoryChunks.v1_2_3.MemoryChunks
InterleaveSets
is an array containing elements of:
InterleaveSets[{item}].Memory
Describes a memory device of the interleave set.
Memory is a link ("@odata.id": URI
) to another resource.
InterleaveSets[{item}].MemoryLevel Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Level of the interleave set for multi-level tiered memory. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
InterleaveSets[{item}].OffsetMiB Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Offset within the DIMM that corresponds to the start of this memory region, with units in MiB |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
InterleaveSets[{item}].RegionId Member of MemoryChunks.v1_2_3.MemoryChunks
Description | DIMM region identifier |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
InterleaveSets[{item}].SizeMiB Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Size of this memory region in MiB |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
IsMirrorEnabled
Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Mirror Enabled status |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
IsSpare
Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Spare enabled status |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryChunkSizeMiB
Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Size of the memory chunk in MiB |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.MemoryChunkSizePercentage
Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Size of chunk in percent of total capacity. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Status
Member of MemoryChunks.v1_2_3.MemoryChunks See the Redfish standard schema and specification for information on common Status object.
MemoryChunksCollection.MemoryChunksCollection
@odata.type: "#MemoryChunksCollection.MemoryChunksCollection"
A Collection of MemoryChunks resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memorydomains/{item}/memorychunks |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
MemoryChunks |
Members (array)
Member of MemoryChunksCollection.MemoryChunksCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MemoryChunksCollection.MemoryChunksCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of MemoryChunksCollection.MemoryChunksCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
MemoryCollection.MemoryCollection
@odata.type: "#MemoryCollection.MemoryCollection"
A Collection of Memory resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memory |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Memory |
Members (array)
Member of MemoryCollection.MemoryCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MemoryCollection.MemoryCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of MemoryCollection.MemoryCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.AmpModeActive
Member of MemoryCollection.MemoryCollection
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Unknown |
The management software cannot determine the AMP, host OS may not have provided it yet. |
Other |
|
None |
The management software cannot determine the AMP, or the system is not configured for AMP. |
Mirroring |
The system is configured for mirrored memory protection. All memory banks are duplicated in mirrored memory, as opposed to only one for online spare memory. If enough ECC errors occur, the spare memory is activated and the memory that is experiencing the errors is disabled. |
OnlineSpare |
A single spare bank of memory is set aside at boot time. If enough ECC errors occur, the spare memory is activated and the memory that is experiencing the errors is disabled. |
RAIDXOR |
The system is configured for AMP with the XOR engine. |
AdvancedECC |
The system is configured for AMP with the Advanced ECC engine. |
Lockstep |
|
A3DC |
The system is configured for AMP with A3DC. |
DIMMECC |
The system is configured for AMP with DIMM ECC (Error Correcting Code) only. |
Oem.Hpe.AmpModeStatus
Member of MemoryCollection.MemoryCollection
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Unknown |
The management software cannot determine the status, host OS may not have provided it yet. |
Other |
The system does not support AMP, or the management software cannot determine the status. |
NotProtected |
The system supports AMP, but the feature is disabled. |
Protected |
The system supports AMP. The feature is enabled but not engaged. |
Degraded |
The system was protected, but AMP is engaged. Therefore, AMP is no longer available. |
DIMMECC |
The system is protected by DIMM ECC (Error Correcting Code) only. |
Mirroring |
The system is protected by AMP in the mirrored mode. No DIMM faults have been detected. |
DegradedMirroring |
The system is protected by AMP in the mirrored mode. One or more DIMM faults have been detected. |
OnlineSpare |
The system is protected by AMP in the hot spare mode. No DIMM faults have been detected. |
DegradedOnlineSpare |
|
RAIDXOR |
The system is protected by AMP in the XOR memory mode. No DIMM faults have been detected. |
DegradedRAIDXOR |
The system is protected by AMP in the XOR memory mode. One or more DIMM faults have been detected. |
AdvancedECC |
The system is protected by AMP in the Advanced ECC mode. |
DegradedAdvancedECC |
The system is protected by AMP in the Advanced ECC mode. One or more DIMM faults have been detected. |
Lockstep |
|
DegradedLockstep |
|
A3DC |
The system is protected by AMP in the A3DC mode. |
DegradedA3DC |
The system is protected by AMP in the A3DC mode. One or more DIMM faults have been deteced. |
Unsupported |
Oem.Hpe.AmpModeSupported (array)
Member of MemoryCollection.MemoryCollection
AmpModeSupported
is an array containing elements of:
AmpModeSupported[{item}] Member of MemoryCollection.MemoryCollection
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
RAIDXOR |
The system can be configured for AMP using the XOR engine. |
DualBoardMirroring |
The system can be configured for mirrored advanced memory protection in a dual memory board configuration. The mirrored memory can be swapped with memory on the same memory board or with memory on the second memory board. |
SingleBoardMirroring |
The system can be configured for mirrored advanced memory protection in a single memory board. |
AdvancedECC |
The system can be configured for Advanced ECC. |
Mirroring |
The system can be configured for mirrored AMP. |
OnlineSpare |
The system can be configured for online spare AMP. |
OnlineSpareRank |
The system can be configured for Online Spare Rank AMP. |
OnlineSpareChannel |
The system can be configured for Online Spare Channel AMP. |
IntersocketMirroring |
The system can be configured for mirrored intersocket AMP between the memory of two processors or boards. |
IntrasocketMirroring |
The system can be configured for mirrored intrasocket AMP between the memory of a single processor or board. |
Lockstep |
|
A3DC |
The system can be configured for A3DC. |
None |
The system cannot be configured for AMP. |
DIMMECC |
The system can be configured for DIMM ECC (Error Correcting Code) only. |
Oem.Hpe.MemoryList (array)
Member of MemoryCollection.MemoryCollection
MemoryList
is an array containing elements of:
MemoryList[{item}].BoardCpuNumber Member of MemoryCollection.MemoryCollection
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryList[{item}].BoardMemoryType Member of MemoryCollection.MemoryCollection
Description | Board Memory Type - DIMM/HBM. |
Type | string or null |
Read Only | True |
Added | iLO6 1.40 |
MemoryList[{item}].BoardNumberOfSockets Member of MemoryCollection.MemoryCollection
Description | The number of present memory module sockets. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryList[{item}].BoardOperationalFrequency Member of MemoryCollection.MemoryCollection
Description | The frequency at which memory on the board is operating in MHz. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryList[{item}].BoardOperationalVoltage Member of MemoryCollection.MemoryCollection
Description | The voltage at which memory on the board is operating in mV. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryList[{item}].BoardTotalMemorySize Member of MemoryCollection.MemoryCollection
Description | The total size of the memory populated on the board in MB. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryDomain.v1_2_1.MemoryDomain
@odata.type: "#MemoryDomain.v1_2_1.MemoryDomain"
The MemoryDomain resource describes a Memory Domain and its configuration. Memory Domains are used to indicate to the client which Memory (DIMMs) can be grouped together in Memory Chunks to form interleave sets or otherwise grouped together.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memorydomains/{item} |
GET |
AllowsBlockProvisioning
Member of MemoryDomain.v1_2_1.MemoryDomain
Description | Indicates if this Memory Domain supports the provisioning of blocks of memory. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
AllowsMemoryChunkCreation
Member of MemoryDomain.v1_2_1.MemoryDomain
Description | Indicates if this Memory Domain supports the creation of Memory Chunks. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
AllowsMirroring
Member of MemoryDomain.v1_2_1.MemoryDomain
Description | Indicates if this Memory Domain supports the creation of Memory Chunks with mirroring enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
AllowsSparing
Member of MemoryDomain.v1_2_1.MemoryDomain
Description | Indicates if this Memory Domain supports the creation of Memory Chunks with sparing enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
InterleavableMemorySets (array)
Member of MemoryDomain.v1_2_1.MemoryDomain
InterleavableMemorySets
is an array containing elements of:
InterleavableMemorySets[{item}].MemorySet (array)
Member of MemoryDomain.v1_2_1.MemoryDomain
MemorySet
is an array containing elements of:
MemorySet[{item}].@odata.id Member of MemoryDomain.v1_2_1.MemoryDomain
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
InterleavableMemorySets[{item}].MemorySet@odata.count Member of MemoryDomain.v1_2_1.MemoryDomain
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
MemoryChunks
A reference to the collection of Memory Chunks associated with this Memory Domain.
MemoryChunks is a link ("@odata.id": URI
) to another resource.
MemoryDomainCollection.MemoryDomainCollection
@odata.type: "#MemoryDomainCollection.MemoryDomainCollection"
A Collection of MemoryDomain resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memorydomains |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
MemoryDomain |
Members (array)
Member of MemoryDomainCollection.MemoryDomainCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MemoryDomainCollection.MemoryDomainCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of MemoryDomainCollection.MemoryDomainCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
MessageRegistryFile.v1_0_4.MessageRegistryFile
@odata.type: "#MessageRegistryFile.v1_0_4.MessageRegistryFile"
The MessageRegistryFile resource describes the Schema File locator resource.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/registries/{item} |
GET |
Languages (array)
Member of MessageRegistryFile.v1_0_4.MessageRegistryFile
Languages
is an array containing elements of:
Languages[{item}] Member of MessageRegistryFile.v1_0_4.MessageRegistryFile
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Location (array)
Member of MessageRegistryFile.v1_0_4.MessageRegistryFile
Location
is an array containing elements of:
Location[{item}].Language Member of MessageRegistryFile.v1_0_4.MessageRegistryFile
Description | The RFC 5646 language code for this schema or registry item. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Location[{item}].Uri Member of MessageRegistryFile.v1_0_4.MessageRegistryFile
Description | Link to locally available URI for schema. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Registry
Member of MessageRegistryFile.v1_0_4.MessageRegistryFile
Description | The Registry Name, Major and Minor version used in MessageID construction. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
MessageRegistryFileCollection.MessageRegistryFileCollection
@odata.type: "#MessageRegistryFileCollection.MessageRegistryFileCollection"
A Collection of MessageRegistryFile resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/registries |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
MessageRegistryFile |
Members (array)
Member of MessageRegistryFileCollection.MessageRegistryFileCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MessageRegistryFileCollection.MessageRegistryFileCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of MessageRegistryFileCollection.MessageRegistryFileCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
MetricDefinition.v1_0_0.MetricDefinition
@odata.type: "#MetricDefinition.v1_0_0.MetricDefinition"
The metadata information about a metric.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricdefinitions/{item} |
GET |
Calculable
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | The types of calculations which can be applied to the metric reading. This property provides information to the client on the suitability of calculatiion using the metric reading. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NonCalculatable |
No calculations should be performed on the metric reading. |
Summable |
The sum of the metric reading across multiple instances is meaningful. |
NonSummable |
The sum of the metric reading across multiple instances is not meaningful. |
CalculationAlgorithm
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | The calculation which is performed on a source metric to obtain the metric being defined. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Average |
The metric is calculated as the average of a metric reading over a sliding time interval. |
Maximum |
The metric is calculated as the maximum value of a metric reading over during a time interval. |
Minimum |
The metric is calculated as the minimum value of a metric reading over a sliding time interval. |
Implementation
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | The implementation of the metric. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
PhysicalSensor |
The metric is implemented as a physical sensor. |
Calculated |
The metric is implemented by applying a calculation on another metric property. The calculation is specified in the CalculationAlgorithm property. |
Synthesized |
The metric is implemented by applying a calculation on one or more metric properties. (The calculation is not specified. For expressing generalized formula, see MathSON). |
DigitalMeter |
The metric is implemented as digital meter. |
IsLinear
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | Indicates whether the metric values are linear (vs non-linear). |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
MaxReadingRange
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | Maximum value for metric reading. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
MetricDataType
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | The data type of the related metric values. The property provides information to the client on the nature of the metric reading. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Boolean |
The data type follows the JSON Boolean definition. |
DateTime |
The data type follows the JSON String definition with the Date-Time format applied. |
Decimal |
The data type follows the JSON Decimal definition. |
Integer |
The data type follows the JSON Integer definition. |
String |
The data type follows the JSON String definition. |
Enumeration |
The data type follows the JSON String definition with a set of enumerations defined. |
MetricProperties (array)
Member of MetricDefinition.v1_0_0.MetricDefinition
MetricProperties
is an array containing elements of:
MetricProperties[{item}] Member of MetricDefinition.v1_0_0.MetricDefinition
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MetricType
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | Specifies the type of metric provided. The property provides information to the client on how the metric can be handled. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Numeric |
The metric is a numeric metric. The metric value is any real number. |
Discrete |
The metric is a discrete metric. The metric value is discrete. The possible values are listed in the DiscreteValues property. |
Gauge |
The metric is a gauge metric. The metric value is a real number. When the metric value reaches the gauges extrema, it stays at that value, until the reading falls within the extrema. |
Counter |
The metric is a counter metric. The metric reading is a non-negative integer which increases monotonically. When a counter reaches its maximum, the value resets to 0 and resumes counting. |
Countdown |
The metric is a countdown metric. The metric reading is a non-negative integer which decreases monotonically. When a counter reaches its minimum, the value resets to preset value and resumes counting down. |
MinReadingRange
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | Minimum value for metric reading. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Units
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | The units of measure for this metric. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
MetricDefinitionCollection.MetricDefinitionCollection
@odata.type: "#MetricDefinitionCollection.MetricDefinitionCollection"
A Collection of MetricDefinition resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricdefinitions |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
MetricDefinition |
Members (array)
Member of MetricDefinitionCollection.MetricDefinitionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MetricDefinitionCollection.MetricDefinitionCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of MetricDefinitionCollection.MetricDefinitionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
MetricReport.v1_0_0.MetricReport
@odata.type: "#MetricReport.v1_0_0.MetricReport"
The metric definitions used to create a metric report.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricreports/{item} |
GET |
MetricReportDefinition
The metric definitions used to create a metric report.
MetricReportDefinition is a link ("@odata.id": URI
) to another resource.
MetricValues (array)
Member of MetricReport.v1_0_0.MetricReport
MetricValues
is an array containing elements of:
MetricValues[{item}].MetricDefinition
A link to the Metric Definition.
MetricDefinition is a link ("@odata.id": URI
) to another resource.
MetricValues[{item}].MetricId Member of MetricReport.v1_0_0.MetricReport
Description | The metric definitions identifier for this metric. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MetricValues[{item}].MetricValue Member of MetricReport.v1_0_0.MetricReport
Description | The value identifies this resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MetricValues[{item}].Timestamp Member of MetricReport.v1_0_0.MetricReport
Description | The time when the value of the metric is obtained. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
MetricReportCollection.MetricReportCollection
@odata.type: "#MetricReportCollection.MetricReportCollection"
A Collection of MetricReport resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricreports |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
MetricReport |
Members (array)
Member of MetricReportCollection.MetricReportCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MetricReportCollection.MetricReportCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of MetricReportCollection.MetricReportCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
MetricReportDefinition.v1_0_0.MetricReportDefinition
@odata.type: "#MetricReportDefinition.v1_0_0.MetricReportDefinition"
A set of metrics that are collected into a metric report.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricreportdefinitions/{item} |
GET |
MetricProperties (array)
Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
MetricProperties
is an array containing elements of:
MetricProperties[{item}] Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MetricReport
Specifies the location where the resultant metric report is placed.
MetricReport is a link ("@odata.id": URI
) to another resource.
MetricReportDefinitionType
Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
Description | Indicates when the metric report is generated. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Periodic |
The metric report is generated at a periodic time interval, specified in the Schedule property. |
OnChange |
The metric report is generated when any of the metric values change. |
OnRequest |
The metric report is generated when a HTTP GET is performed on the specified metric report. |
Metrics (array)
Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
Metrics
is an array containing elements of:
Metrics[{item}].CollectionDuration Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
Description | Specifies the duration over which the function is computed. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Metrics[{item}].CollectionFunction Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
Description | Specifies the function to apply to the list of metric properties. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Average |
The metric is calculated as the average of a metric reading over a sliding time interval. |
Maximum |
The metric is calculated as the maximum value of a metric reading over during a time interval. |
Minimum |
The metric is calculated as the minimum value of a metric reading over a sliding time interval. |
Summation |
The metric is calculated as the sum of the values over a sliding time interval. |
Metrics[{item}].CollectionTimeScope Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
Description | The time scope of the related metric values. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Point |
The corresponding metric values apply to a point in time. On the corresponding metric value instances, the value of Timestamp shall specify the point in time. |
Interval |
The corresponding metric values apply to a time interval. On the corresponding metric value instances, the value of Timestamp shall specify the end of the time interval and Duration shall specify its duration. |
StartupInterval |
The corresponding metric values apply to a time interval that began at the startup of the measured resource (i.e. the Resources associated by Links.MetricDefinitionForResources). On the corresponding metric value instances, the value of Timestamp shall specify the end of the time interval. The value of Duration shall specifies the duration between startup of the resource and TimeStamp. |
Metrics[{item}].MetricId Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
Description | Specifies the label for the metric definition which is derived by applying the CollectionFunction to the metric property. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Metrics[{item}].MetricProperties (array)
Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
MetricProperties
is an array containing elements of:
MetricProperties[{item}] Member of MetricReportDefinition.v1_0_0.MetricReportDefinition
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of MetricReportDefinition.v1_0_0.MetricReportDefinition See the Redfish standard schema and specification for information on common Status object.
MetricReportDefinitionCollection.MetricReportDefinitionCollection
@odata.type: "#MetricReportDefinitionCollection.MetricReportDefinitionCollection"
A Collection of MetricReportDefinition resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricreportdefinitions |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
MetricReportDefinition |
Members (array)
Member of MetricReportDefinitionCollection.MetricReportDefinitionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MetricReportDefinitionCollection.MetricReportDefinitionCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of MetricReportDefinitionCollection.MetricReportDefinitionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
NetworkAdapter.v1_9_0.NetworkAdapter
@odata.type: "#NetworkAdapter.v1_9_0.NetworkAdapter"
A NetworkAdapter represents the physical network adapter capable of connecting to a computer network. Examples include but are not limited to Ethernet, Fibre Channel, and converged network adapters.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters/{item} |
GET POST PATCH |
/redfish/v1/chassis/{item}/networkadapters/{item}/settings |
GET POST PATCH |
@Redfish.Settings
Member of NetworkAdapter.v1_9_0.NetworkAdapter See the Redfish standard schema and specification for information on common @Redfish properties.
Controllers (array)
Member of NetworkAdapter.v1_9_0.NetworkAdapter
Controllers
is an array containing elements of:
Controllers[{item}].ControllerCapabilities Controllers[{item}].ControllerCapabilities.DataCenterBridging Controllers[{item}].ControllerCapabilities.DataCenterBridging.Capable Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The value of this property shall be a boolean indicating whether this controller is capable of Data Center Bridging (DCB). |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].ControllerCapabilities.NPAR Controllers[{item}].ControllerCapabilities.NPAR.NparCapable Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | Indicates whether or not NIC function partitioning is supported by a controller. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].ControllerCapabilities.NPAR.NparEnabled Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | When true, NIC function partitioning is active on this controller. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Controllers[{item}].ControllerCapabilities.NPIV Controllers[{item}].ControllerCapabilities.NPIV.MaxDeviceLogins Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The maximum number of N_Port ID Virtualization (NPIV) logins allowed simultaneously from all ports on this controller. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].ControllerCapabilities.NPIV.MaxPortLogins Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The maximum number of N_Port ID Virtualization (NPIV) logins allowed per physical port on this controller. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].ControllerCapabilities.NetworkDeviceFunctionCount Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The maximum number of physical functions available on this controller. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].ControllerCapabilities.NetworkPortCount Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The number of physical ports on this controller. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].ControllerCapabilities.VirtualizationOffload Controllers[{item}].ControllerCapabilities.VirtualizationOffload.SRIOV Controllers[{item}].ControllerCapabilities.VirtualizationOffload.SRIOV.SRIOVVEPACapable Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The value of this property shall be a boolean indicating whether this controller supports Single Root Input/Output Virtualization (SR-IOV) in Virtual Ethernet Port Aggregator (VEPA) mode. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].ControllerCapabilities.VirtualizationOffload.VirtualFunction Controllers[{item}].ControllerCapabilities.VirtualizationOffload.VirtualFunction.DeviceMaxCount Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The maximum number of Virtual Functions (VFs) supported by this controller. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].ControllerCapabilities.VirtualizationOffload.VirtualFunction.MinAssignmentGroupSize Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The minimum number of Virtual Functions (VFs) that can be allocated or moved between physical functions for this controller. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].ControllerCapabilities.VirtualizationOffload.VirtualFunction.NetworkPortMaxCount Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The maximum number of Virtual Functions (VFs) supported per network port for this controller. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].FirmwarePackageVersion Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The version number of the user-facing firmware package. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].Links
Controllers[{item}].Links.NetworkDeviceFunctions (array)
Member of NetworkAdapter.v1_9_0.NetworkAdapter
NetworkDeviceFunctions
is an array containing elements of:
NetworkDeviceFunctions[{item}].@odata.id Member of NetworkAdapter.v1_9_0.NetworkAdapter
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Controllers[{item}].Links.Ports (array)
Member of NetworkAdapter.v1_9_0.NetworkAdapter
Ports
is an array containing elements of:
Ports[{item}].@odata.id Member of NetworkAdapter.v1_9_0.NetworkAdapter
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Controllers[{item}].Location Controllers[{item}].Location.PartLocation Controllers[{item}].Location.PartLocation.LocationOrdinalValue Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The number that represents the location of the part. If LocationType is slot and this unit is in slot 2, the LocationOrdinalValue is 2. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].Location.PartLocation.LocationType Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The location types for PartLocation. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Slot |
The slot as the type of location. |
Bay |
The bay as the type of location. |
Connector |
The connector as the type of location. |
Socket |
The socket as the type of location. |
Embedded |
Embedded within a part. |
Controllers[{item}].Location.PartLocation.Orientation Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The orientation for the ordering of the part location ordinal value. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
FrontToBack |
The ordering for LocationOrdinalValue is front to back. |
BackToFront |
The ordering for the LocationOrdinalValue is back to front. |
TopToBottom |
The ordering for the LocationOrdinalValue is top to bottom. |
BottomToTop |
The ordering for LocationOrdinalValue is bottom to top. |
LeftToRight |
The ordering for the LocationOrdinalValue is left to right. |
RightToLeft |
The ordering for the LocationOrdinalValue is right to left. |
Controllers[{item}].Location.PartLocation.Reference Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The reference area for the location of the part. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Top |
The part is in the top of the unit. |
Bottom |
The part is in the bottom of the unit. |
Front |
The part is in the front of the unit. |
Rear |
The part is in the rear of the unit. |
Left |
The part is on the left side of of the unit. |
Right |
The part is on the right side of the unit. |
Middle |
The part is in the middle of the unit. |
Controllers[{item}].Location.PartLocation.ServiceLabel Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The label of the part location, such as a silk-screened name or a printed label. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].Location.Placement Controllers[{item}].Location.Placement.AdditionalInfo Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | Area designation or other additional info. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Controllers[{item}].Location.Placement.Rack Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The name of a rack location within a row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Controllers[{item}].Location.Placement.RackOffset Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The vertical location of the item, in terms of RackOffsetUnits. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Controllers[{item}].Location.Placement.RackOffsetUnits Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The type of rack unit in use. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OpenU |
A rack unit that is equal to 48 mm (1.89 in). |
EIA_310 |
A rack unit that is equal to 1.75 in (44.45 mm). |
Controllers[{item}].Location.Placement.Row Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The name of the row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Location
Location.PartLocation Location.PartLocation.LocationOrdinalValue Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The number that represents the location of the part. If LocationType is slot and this unit is in slot 2, the LocationOrdinalValue is 2. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.10 |
Location.PartLocation.LocationType Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The location types for PartLocation. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Slot |
The slot as the type of location. |
Bay |
The bay as the type of location. |
Connector |
The connector as the type of location. |
Socket |
The socket as the type of location. |
Embedded |
Embedded within a part. |
Location.PartLocation.Orientation Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The orientation for the ordering of the part location ordinal value. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
FrontToBack |
The ordering for LocationOrdinalValue is front to back. |
BackToFront |
The ordering for the LocationOrdinalValue is back to front. |
TopToBottom |
The ordering for the LocationOrdinalValue is top to bottom. |
BottomToTop |
The ordering for LocationOrdinalValue is bottom to top. |
LeftToRight |
The ordering for the LocationOrdinalValue is left to right. |
RightToLeft |
The ordering for the LocationOrdinalValue is right to left. |
Location.PartLocation.Reference Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The reference area for the location of the part. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Top |
The part is in the top of the unit. |
Bottom |
The part is in the bottom of the unit. |
Front |
The part is in the front of the unit. |
Rear |
The part is in the rear of the unit. |
Left |
The part is on the left side of of the unit. |
Right |
The part is on the right side of the unit. |
Middle |
The part is in the middle of the unit. |
Location.PartLocation.ServiceLabel Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The label of the part location, such as a silk-screened name or a printed label. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Location.Placement Location.Placement.AdditionalInfo Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | Area designation or other additional info. |
Type | string or null |
Read Only | False |
Added | iLO6 1.10 |
Location.Placement.Rack Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The name of a rack location within a row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.10 |
Location.Placement.RackOffset Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The vertical location of the item, in terms of RackOffsetUnits. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.10 |
Location.Placement.RackOffsetUnits Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The type of rack unit in use. |
Type | string or null |
Read Only | False |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OpenU |
A rack unit that is equal to 48 mm (1.89 in). |
EIA_310 |
A rack unit that is equal to 1.75 in (44.45 mm). |
Location.Placement.Row Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The name of the row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.10 |
Manufacturer
Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The manufacturer or OEM of this network adapter. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Model
Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The model string used by the manufacturer to reference this network adapter. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
NetworkDeviceFunctions
A reference to the collection of physical network device functions associated with this network adapter.
NetworkDeviceFunctions is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.CLPVersion
Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | Option ROM Systems Management Architecture for Server Hardware (SMASH) Command Line Protocol (CLP) support version. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Controllers (array)
Member of NetworkAdapter.v1_9_0.NetworkAdapter
Controllers
is an array containing elements of:
Controllers[{item}].ConfigurationStatus
Controllers[{item}].ConfigurationStatus.Detail (array)
Member of NetworkAdapter.v1_9_0.NetworkAdapter
Detail
is an array containing elements of:
Detail[{item}].Group Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | Configuration group identifier. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Detail[{item}].SubGroup Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | Configuration sub-group identifier. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Detail[{item}].Summary Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | A digest value representing the current state of configuration for this group/sub-group. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].ConfigurationStatus.Summary Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | A digest value representing the current configuration state of this network adapter controller. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].DeviceLimitationsBitmap Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | Indicates any unique device limitations. A value of 0 indicates no limitations are present. When set, bit 0 indicates that the device cannot validate data received when in standby power. All other bit mappings are reserved. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].EdgeVirtualBridging Controllers[{item}].EdgeVirtualBridging.ChannelDescriptionTLVCapable Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | When true, this controller supports HPE Flex10Qbg Channel Description TLVs. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].EdgeVirtualBridging.ChannelLinkControlTLVCapable Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | When true, this controller supports HPE Flex10Qbg Channel Link Control TLVs. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].EmbeddedLLDPFunctions Controllers[{item}].EmbeddedLLDPFunctions.Enabled Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | NOTE: This is a read-only property when the adapter is installed on an HPE Synergy server. When false, globally disables device functions on this controller which utilize HPE defined embedded LLDP. When set false will also disable EVB, FCoE, RoCE, and DCBX capabilities on this controller. This property does not affect Ethernet NPAR functionality. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Controllers[{item}].EmbeddedLLDPFunctions.Optional Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | When true, indicates that this controller has the ability to globally disable all network device functions which utilize HPE defined embedded LLDP. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].FactoryDefaultsCurrentlyActive Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | When true, this controller’s configuration matches factory default settings. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].FunctionTypeLimits (array)
Member of NetworkAdapter.v1_9_0.NetworkAdapter
FunctionTypeLimits
is an array containing elements of:
FunctionTypeLimits[{item}].ConstraintDescription Member of NetworkAdapter.v1_9_0.NetworkAdapter
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
FunctionTypeLimits[{item}].EthernetResourcesConsumed Member of NetworkAdapter.v1_9_0.NetworkAdapter
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
FunctionTypeLimits[{item}].FCoEResourcesConsumed Member of NetworkAdapter.v1_9_0.NetworkAdapter
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
FunctionTypeLimits[{item}].RDMAResourcesConsumed Member of NetworkAdapter.v1_9_0.NetworkAdapter
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
FunctionTypeLimits[{item}].TotalSharedResourcesAvailable Member of NetworkAdapter.v1_9_0.NetworkAdapter
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
FunctionTypeLimits[{item}].iSCSIResourcesConsumed Member of NetworkAdapter.v1_9_0.NetworkAdapter
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Controllers[{item}].FunctionTypes (array)
Member of NetworkAdapter.v1_9_0.NetworkAdapter
FunctionTypes
is an array containing elements of:
FunctionTypes[{item}] Member of NetworkAdapter.v1_9_0.NetworkAdapter
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Ethernet |
Has Ethernet functionality. |
FibreChannel |
Has native FibreChannel functionality. |
iSCSI |
Has iSCSI functionality. |
FCoE |
Has FibreChannel over Ethernet functionality. |
InfiniBand |
Has InfiniBand functionality. |
RoCE |
Has RDMA over Converged Ethernet protocol functionality. |
iWarp |
Has internet Wide-area RDMA protocol functionality. |
Controllers[{item}].MostRecentConfigurationChangeSource Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | Type of the last client to have changed configuration on this device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
None |
No change detected. |
OS |
Operating System Driver |
VendorControl |
Vendor Control Software |
VirtualConnect |
Virtual Connect |
CNU |
Converged Network Utility |
Other |
Other configuration or diagnostic software. |
Redfish |
Redfish Client |
UEFI-HII |
UEFI Human Interface Infrastructure |
Controllers[{item}].RDMASupport (array)
Member of NetworkAdapter.v1_9_0.NetworkAdapter
RDMASupport
is an array containing elements of:
RDMASupport[{item}] Member of NetworkAdapter.v1_9_0.NetworkAdapter
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
None |
No RDMA support. |
RoCE |
RDMA over Converged Ethernet supported. |
iWARP |
iWARP supported. |
Controllers[{item}].UnderlyingDataSource Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | Protocol through which Redfish data is supplied for this adapter. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
DCi |
HPE Proprietary DCi protocol |
RDE |
DMTF RDE protocol |
Oem.Hpe.FactoryDefaultsActuationBehavior
Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | Indicates the implementation timing of a reset to factory default settings request, when made with the server in the standby power state. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Immediate |
Defaults take effect within 2 seconds of being applied. |
AtFullPower |
Defaults take effect within 5 seconds of power being applied. |
AtNextReboot |
Defaults take effect on next reboot to full power. |
Oem.Hpe.FcPorts (array)
Member of NetworkAdapter.v1_9_0.NetworkAdapter
FcPorts
is an array containing elements of:
FcPorts[{item}].PortNumber Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | Port Number. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.10 |
FcPorts[{item}].WWNN Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | World Wide Node Name. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
FcPorts[{item}].WWPN Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | World Wide Port Name. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Oem.Hpe.PCAVersion
Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | Printed Circuit Assembly number for the circuit board comprising this device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PhysicalPorts (array)
Member of NetworkAdapter.v1_9_0.NetworkAdapter
PhysicalPorts
is an array containing elements of:
PhysicalPorts[{item}].BadReceives Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | A count of frames that were received by the adapter but which had an error. This counter is the sum of mib items cpqNicIfPhysAdapterAlignmentErrors, cpqNicIfPhysAdapterFCSErrors, cpqNicIfPhysAdapterFrameTooLongs, and cpqNicIfPhysAdapterInternalMacReceiveErrors. If this counter increments frequently, check the more detailed error statistics and take appropriate action. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.10 |
PhysicalPorts[{item}].BadTransmits Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | A count of frames that were not transmitted by the adapter because of an error. This counter is the sum of MIB items cpqNicIfPhysAdapterDeferredTransmissions, cpqNicIfPhysAdapterLateCollisions, cpqNicIfPhysAdapterExcessiveCollisions, cpqNicIfPhysAdapterCarrierSenseErrors, and cpqNicIfPhysAdapterInternalMacTransmitErrors. If this counter increments frequently, check the more detailed error statistics and take appropriate action. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.10 |
PhysicalPorts[{item}].FullDuplex Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | Full-duplex data transmission means that data can be transmitted in both directions on a signal carrier at the same time. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.10 |
PhysicalPorts[{item}].GoodReceives Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | A count of frames successfully received by the physical adapter. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.10 |
PhysicalPorts[{item}].GoodTransmits Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | A count of frames successfully transmitted by the physical adapter. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.10 |
PhysicalPorts[{item}].IPv4Addresses (array)
Member of NetworkAdapter.v1_9_0.NetworkAdapter
IPv4Addresses
is an array containing elements of:
IPv4Addresses[{item}].Address Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | This is the IPv4 Address. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
PhysicalPorts[{item}].IPv6Addresses (array)
Member of NetworkAdapter.v1_9_0.NetworkAdapter
IPv6Addresses
is an array containing elements of:
IPv6Addresses[{item}].Address Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | This is the IPv6 Address. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Format | ipv6 |
PhysicalPorts[{item}].LinkStatus Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The link status of this interface (port). |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value |
---|
LinkUp |
NoLink |
LinkDown |
Null |
PhysicalPorts[{item}].MacAddress Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The port MAC address. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
PhysicalPorts[{item}].SpeedMbps Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | An estimate of the interface’s current bandwidth in Megabits per second. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.10 |
PhysicalPorts[{item}].Status Member of NetworkAdapter.v1_9_0.NetworkAdapter See the Redfish standard schema and specification for information on common Status object.
PhysicalPorts[{item}].StructuredName Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | PCI device structured name in UTF-8 format (e.g. ‘NIC.LOM.1.1’ - see PCIDevices in /rest/v1/Systems/x/PCIDevices - this comes from SMBIOS |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
PhysicalPorts[{item}].Team Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | If a port is configured for NIC teaming, the name of the configured link between the physical ports that form a logical network adapter. This value is displayed for system NICs only (embedded and stand-up). |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
PhysicalPorts[{item}].UEFIDevicePath Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | UEFIDevice Path for correlation purposes |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Oem.Hpe.RedfishConfiguration
Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | Controls Redfish configuration write access to network adapters. When present and disabled, network adapter information is read-only. Note that some HPE advanced network adapters will present a reduced level of capability when disabled. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Enabled |
The Redfish management interface is enabled to make changes on this network adapter. To return to the Disabled state, a network adapter reset to factory default operation is required. |
Disabled |
The network adapter is operating in read-only mode relative to the Redfish management interface. To transition to this state, a network adapter reset to factory default operation is required. |
Oem.Hpe.StructuredName
Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | PCI device structured name in UTF-8 format (e.g. ‘NIC.LOM.1.1’ - see PCIDevices in /rest/v1/Systems/x/PCIDevices - this comes from SMBIOS |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Oem.Hpe.UEFIDevicePath
Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | UEFIDevice Path for correlation purposes |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
PartNumber
Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | Manufacturer’s Part number for this network adapter. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Ports
A reference to the collection of physical network ports associated with this network adapter.
Ports is a link ("@odata.id": URI
) to another resource.
SKU
Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The value of this property shall contain the Stock Keeping Unit (SKU) for the network adapter. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SerialNumber
Member of NetworkAdapter.v1_9_0.NetworkAdapter
Description | The serial number for this network adapter. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of NetworkAdapter.v1_9_0.NetworkAdapter See the Redfish standard schema and specification for information on common Status object.
Actions
NetworkAdapter.ResetSettingsToDefault Member of NetworkAdapter.v1_9_0.NetworkAdapter There are no parameters for this action.
HpeNetworkAdapter.FlushConfigurationToNVM Member of NetworkAdapter.v1_9_0.NetworkAdapter There are no parameters for this action.
NetworkAdapter.FlushConfigurationToNVM Member of NetworkAdapter.v1_9_0.NetworkAdapter NOTE: Deprecated, will be removed in a future release. Replaced by HpeNetworkAdapter.FlushConfigurationToNVM.
There are no parameters for this action.
NetworkAdapterCollection.NetworkAdapterCollection
@odata.type: "#NetworkAdapterCollection.NetworkAdapterCollection"
A Collection of NetworkAdapter resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
NetworkAdapter |
Members (array)
Member of NetworkAdapterCollection.NetworkAdapterCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of NetworkAdapterCollection.NetworkAdapterCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of NetworkAdapterCollection.NetworkAdapterCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.MemberContents
Member of NetworkAdapterCollection.NetworkAdapterCollection
Description | Provides the discovery status of this collection. For some server platforms, only partial device discovery is possible under auxiliary power. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
AllDevices |
The server state allows complete device discovery. All installed devices are listed as members. |
AuxPowerDevices |
The server architecture may not support power to all installed devices in the current auxiliary power state. Only devices capable of operating in this power state are listed as members. Additional devices may be listed when the server is fully powered. |
NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
@odata.type: "#NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction"
A Network Device Function represents a logical interface exposed by the network adapter.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters/{item}/networkdevicefunctions/{item} |
GET POST PATCH |
/redfish/v1/chassis/{item}/networkadapters/{item}/networkdevicefunctions/{item}/settings |
GET POST PATCH |
/redfish/v1/systems/{item}/networkinterfaces/{item}/networkdevicefunctions/{item} |
GET POST PATCH |
/redfish/v1/systems/{item}/networkinterfaces/{item}/networkdevicefunctions/{item}/settings |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
@Redfish.Settings/SettingsObject |
NetworkDeviceFunction |
@Redfish.Settings
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction See the Redfish standard schema and specification for information on common @Redfish properties.
AssignablePhysicalNetworkPorts (array)
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
AssignablePhysicalNetworkPorts
is an array containing elements of:
AssignablePhysicalNetworkPorts[{item}].@odata.id Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
BootMode
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | Network device boot mode configuration values. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Disabled |
Do not indicate to UEFI/BIOS that this device is bootable. |
PXE |
Boot this device using the embedded PXE support. Only applicable if the NetworkDeviceFunctionType is set to Ethernet. Not supported by HPE. |
iSCSI |
Boot this device using the embedded iSCSI boot support and configuration. Only applicable if the NetworkDeviceFunctionType is set to iSCSI. |
FibreChannel |
Boot this device using the embedded Fibre Channel support and configuration. Only applicable if the NetworkDeviceFunctionType is set to FibreChannel. |
FibreChannelOverEthernet |
Boot this device using the embedded Fibre Channel over Ethernet (FCoE) boot support and configuration. Only applicable if the NetworkDeviceFunctionType is set to FibreChannelOverEthernet. |
DeviceEnabled
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | A boolean indicating whether the network device function is enabled. Disabled network device functions shall not be enumerated or seen by the operating system. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet
Ethernet.MACAddress Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The effective current MAC Address of this network device function. If an assignable MAC address is not supported, this is a read only alias of the PermanentMACAddress. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.MTUSize Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The Maximum Transmission Unit (MTU) configured for this Network Device Function. This value serves as a default for the OS driver when booting. The value only takes-effect on boot. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.PermanentMACAddress Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The Permanent MAC Address of this network device function (physical function). This value is typically programmed during the manufacturing time. This address is not assignable. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
FibreChannel
FibreChannel.AllowFIPVLANDiscovery Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | For FCoE connections, a boolean indicating whether the FIP VLAN Discovery Protocol is used to determine the FCoE VLAN ID selected by the network device function for the FCoE connection. If true, and the FIP VLAN Discovery succeeds, the FCoEActiveVLANId property shall reflect the FCoE VLAN ID to be used for all FCoE traffic. If false, or if the FIP VLAN Discovery protocol fails, the FCoELocalVLANId shall be used for all FCoE traffic and the FCoEActiveVLANId shall reflect the FCoELocalVLANId. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
FibreChannel.BootTargets (array)
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
BootTargets
is an array containing elements of:
BootTargets[{item}].BootPriority Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The relative priority for this entry in the boot targets array. Lower numbers shall represent higher priority, with zero being the highest priority. The BootPriority shall be unique for all entries of the BootTargets array. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
BootTargets[{item}].LUNID Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The Logical Unit Number (LUN) ID to boot from on the device referred to by the corresponding WWPN. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
BootTargets[{item}].WWPN Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The value of this property shall be World-Wide Port Name (WWPN) to boot from. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
FibreChannel.FCoEActiveVLANId Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | For FCoE connections, the value of this property shall be null or a VLAN ID currently being used for FCoE traffic. When the FCoE link is down this value shall be null. When the FCoE link is up this value shall be either the FCoELocalVLANId property or a VLAN discovered via the FIP protocol. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
FibreChannel.FCoELocalVLANId Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | For FCoE connections, the locally configured VLAN ID. This value shall be used for FCoE traffic to this network device function during boot unless AllowFIPVLANDiscovery is true and a valid FCoE VLAN ID is found via the FIP VLAN Discovery Protocol. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
FibreChannel.PermanentWWNN Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The permanent World-Wide Node Name (WWNN) of this network device function (physical function). This value is typically programmed during the manufacturing time. This address is not assignable. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
FibreChannel.PermanentWWPN Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
FibreChannel.WWNN Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The value of this property shall be the effective current World-Wide Node Name (WWNN) of this network device function (physical function). If an assignable WWNN is not supported, this is a read only alias of the PermanentWWNN. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
FibreChannel.WWNSource Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The configuration source of the WWNs for this connection (WWPN and WWNN). |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
ConfiguredLocally |
The set of FC/FCoE boot targets was applied locally through API or UI. |
ProvidedByFabric |
The set of FC/FCoE boot targets was applied by the Fibre Channel fabric. |
FibreChannel.WWPN Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The effective current World-Wide Port Name (WWPN) of this network device function (physical function). If an assignable WWPN is not supported, this is a read only alias of the PermanentWWPN. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
MaxVirtualFunctions
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The number of virtual functions (VFs) availbale for this network device function. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
NetDevFuncCapabilities (array)
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
NetDevFuncCapabilities
is an array containing elements of:
NetDevFuncCapabilities[{item}] Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Disabled |
Neither enumerated nor visible to the operating system. |
Ethernet |
Appears to the operating system as an Ethernet device. |
FibreChannel |
Appears to the operating system as a Fibre Channel device. |
iSCSI |
Appears to the operating system as an iSCSI device. |
FibreChannelOverEthernet |
Appears to the operating system as an FCoE device. |
NetDevFuncType
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The configured capability of this network device function. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Disabled |
Neither enumerated nor visible to the operating system. |
Ethernet |
Appears to the operating system as an Ethernet device. |
FibreChannel |
Appears to the operating system as a Fibre Channel device. |
iSCSI |
Appears to the operating system as an iSCSI device. |
FibreChannelOverEthernet |
Appears to the operating system as an FCoE device. |
Oem.Hpe.BootTargetSource
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | Controls the source of boot target parameters for this network device function. This property can only be configured when the network device function is not in the Disabled state. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
UEFI |
Boot target parameters are under control of UEFI and the device option ROM. Any target parameters configured on this network device function are ignored. |
NetworkDeviceFunction |
Boot target parameters as configured on this network device function will be used. |
None |
Boot mode is configured disabled, and no target source applies. |
Oem.Hpe.ConnectionID
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The Connection ID to be used with EVB, in IETF RFC-4122 UUID format. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.NetDevFuncCapabilities (array)
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
NetDevFuncCapabilities
is an array containing elements of:
NetDevFuncCapabilities[{item}] Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Disabled |
Neither enumerated nor visible to the operating system. |
Ethernet |
Appears to the operating system as an Ethernet device. |
FibreChannel |
Appears to the operating system as a Fibre Channel device. |
iSCSI |
Appears to the operating system as an iSCSI device. |
FCoE |
Appears to the operating system as an FCoE device. |
InfiniBand |
Appears to the operating system as an InfiniBand device. |
RoCE |
(Deprecated function type for some adapters, in iLO 1.40+) Appears to the operating system as an RDMA over converged Ethernet device. |
iWarp |
(Deprecated function type for some adapters, in iLO 1.40+) Appears to the operating system as an iWarp RDMA device. |
Oem.Hpe.NetDevFuncType
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The presently configured interconnection capability of this network device function. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Disabled |
This function is disabled, and is neither enumerated nor visible to the operating system. |
Ethernet |
This function is configured to operate as an Ethernet device. |
FibreChannel |
This function is configured to operate as a Fibre Channel device. |
iSCSI |
This function is configured to operate as an iSCSI device. |
FCoE |
This function is configured to oeprate as an FCoE device. |
InfiniBand |
|
RCoE |
|
iWarp |
(Deprecated function type for some adapters, in iLO 1.40+) This function is configured to operate as an iWarp RDMA device. |
Oem.Hpe.SupportedFCBootTargetCount
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The number of Fibre Channel boot targets supported by this network device function. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.VirtualLinkStatus
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | Current status of the EVB Virtual Link (S-Channel) supporting this function. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
NoChannel |
Port link is down, or the connected switch has not assigned an SVID. |
SwitchChannelDown |
SVID is assigned but Virtual Link status is down. |
HostDriverDown |
SVID is assigned and Virtual Link status is up, but the host OS driver is inactive. |
VirtualLinkUp |
SVID is assigned, Virual Link status is up, and the host OS driver is active. |
Oem.Hpe.WakeOnLANEnabled
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | Enables Ethernet Wake On LAN (WoL) capability for this function when true. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Status
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction See the Redfish standard schema and specification for information on common Status object.
VirtualFunctionsEnabled
Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | Indicates whether Single Root I/O Virtualization (SR-IOV) Virual Functions (VFs) are enabled for this network device function. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
iSCSIBoot
iSCSIBoot.AuthenticationMethod Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | iSCSI Boot authentication method configuration values. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
None |
No iSCSI authentication is used. |
CHAP |
iSCSI Challenge Handshake Authentication Protocol (CHAP) authentication is used. |
MutualCHAP |
iSCSI Mutual Challenge Handshake Authentication Protocol (CHAP) authentication is used. |
iSCSIBoot.CHAPSecret Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The shared secret for CHAP authentication. Must be 0, 12, or 16 characters in length. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.CHAPUsername Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The username for CHAP authentication. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.IPAddressType Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The type of IP address (IPv6 or IPv4) being populated in the iSCSIBoot IP address fields. Mixing of IPv6 and IPv4 addresses on the same network device function is not allowed. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
IPv4 |
IPv4 addressing is used for all IP-fields in this object. |
IPv6 |
IPv6 addressing is used for all IP-fields in this object. |
iSCSIBoot.IPMaskDNSViaDHCP Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | When true, the iSCSI boot initiator will use DHCP to obtain the iniator name, IP address, and netmask. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.InitiatorDefaultGateway Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The IPv6 or IPv4 iSCSI boot default gateway. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.InitiatorIPAddress Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The IPv6 or IPv4 address of the iSCSI boot initiator. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.InitiatorName Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The iSCSI initiator name. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.InitiatorNetmask Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The IPv6 or IPv4 netmask of the iSCSI boot initiator. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.MutualCHAPSecret Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The CHAP secret for 2-way CHAP authentication. Must be 0, 12, or 16 characters in length. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.MutualCHAPUsername Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The CHAP username for 2-way CHAP authentication. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.PrimaryDNS Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The IPv6 or IPv4 address of the primary DNS server for the iSCSI boot initiator. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.PrimaryLUN Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The logical unit number (LUN) for the primary iSCSI boot target. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.PrimaryTargetIPAddress Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The IP address (IPv6 or IPv4) for the primary iSCSI boot target. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.PrimaryTargetName Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The name of the primary iSCSI boot target, iSCSI Qualified Name (IQN). |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.PrimaryTargetTCPPort Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The TCP port for the primary iSCSI boot target. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.PrimaryVLANEnable Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | This indicates if the primary VLAN is enabled. Not supported by HPE. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.PrimaryVLANId Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The 802.1q VLAN ID to use for iSCSI boot for both the primary and secondary targets. Assign null value to disable. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.RouterAdvertisementEnabled Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | A boolean indicating whether IPv6 router advertisement is enabled for the iSCSI boot target. This setting shall only apply to IPv6 configurations. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.SecondaryDNS Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The value of this property shall be the IPv6 or IPv4 address of the secondary DNS server for the iSCSI boot initiator. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.SecondaryLUN Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The logical unit number (LUN) for the secondary iSCSI boot target. Not supported by HPE. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.SecondaryTargetIPAddress Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The IP address (IPv6 or IPv4) for the secondary iSCSI boot target. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.SecondaryTargetName Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The name of the iSCSI secondary boot target, iSCSI Qualified Name (IQN). Not supported by HPE. The value from PrimaryTargetName will be used for the secondary iSCSI boot target if configured. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.SecondaryTargetTCPPort Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The TCP port for the secondary iSCSI boot target. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.SecondaryVLANEnable Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | This indicates if the secondary VLAN is enabled. Not supported by HPE. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.SecondaryVLANId Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | The 802.1q VLAN ID to use for iSCSI boot from the secondary target. Not supported by HPE. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
iSCSIBoot.TargetInfoViaDHCP Member of NetworkDeviceFunction.v1_8_0.NetworkDeviceFunction
Description | When true indicates the iSCSI boot target name, LUN, IP address, and netmask should be obtained from DHCP. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
NetworkDeviceFunctionCollection.NetworkDeviceFunctionCollection
@odata.type: "#NetworkDeviceFunctionCollection.NetworkDeviceFunctionCollection"
A Collection of NetworkDeviceFunction resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters/{item}/networkdevicefunctions |
GET |
/redfish/v1/systems/{item}/networkinterfaces/{item}/networkdevicefunctions |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
NetworkDeviceFunction |
Members (array)
Member of NetworkDeviceFunctionCollection.NetworkDeviceFunctionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of NetworkDeviceFunctionCollection.NetworkDeviceFunctionCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of NetworkDeviceFunctionCollection.NetworkDeviceFunctionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
NetworkInterface.v1_2_0.NetworkInterface
@odata.type: "#NetworkInterface.v1_2_0.NetworkInterface"
A NetworkInterface contains references linking NetworkAdapter, Port, and NetworkDeviceFunction resources and represents the functionality available to the containing system.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/networkinterfaces/{item} |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
NetworkDeviceFunctions |
Collection of NetworkDeviceFunction |
NetworkDeviceFunctions
link to collection of membertype NetworkDeviceFunction. The collection of device functions avaliable on this network interface.
NetworkDeviceFunctions is a link ("@odata.id": URI
) to another resource.
Ports
Link to a collection of membertype Port. The collection of ports avaliable on this network interface.
Ports is a link ("@odata.id": URI
) to another resource.
Status
Member of NetworkInterface.v1_2_0.NetworkInterface See the Redfish standard schema and specification for information on common Status object.
NetworkInterfaceCollection.NetworkInterfaceCollection
@odata.type: "#NetworkInterfaceCollection.NetworkInterfaceCollection"
A Collection of NetworkInterface resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/networkinterfaces |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
NetworkInterface |
Members (array)
Member of NetworkInterfaceCollection.NetworkInterfaceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of NetworkInterfaceCollection.NetworkInterfaceCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of NetworkInterfaceCollection.NetworkInterfaceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.MemberContents
Member of NetworkInterfaceCollection.NetworkInterfaceCollection
Description | Provides the discovery status of this collection. For some server platforms, only partial device discovery is possible under auxiliary power. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
AllDevices |
The server state allows complete device discovery. All installed devices are listed as members. |
AuxPowerDevices |
The server is in the auxiliary power state and only devices capable of operating in this power state are listed as members. Additional devices may be listed when the server is fully powered. |
PCIeDevice.v1_5_0.PCIeDevice
@odata.type: "#PCIeDevice.v1_5_0.PCIeDevice"
This is the schema definition for the PCIeDevice resource. It represents the properties of a PCIe Device attached to a System.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/pciedevices/{item} |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
PCIeFunctions |
PCIeFunction |
AssetTag
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The user-assigned asset tag for this PCIe device. |
Type | string or null |
Read Only | False |
Added | iLO6 1.20 |
DeviceType
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The device type for this PCIe device. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
SingleFunction |
A single-function PCIe device. |
MultiFunction |
A multi-function PCIe device. |
Simulated |
A PCIe device which is not currently physically present, but is being simulated by the PCIe infrastructure. |
FirmwareVersion
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The version of firmware for this PCIe device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Manufacturer
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The manufacturer of this PCIe device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Model
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The model number for the PCIe device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.FirmwareVersion (array)
Member of PCIeDevice.v1_5_0.PCIeDevice
FirmwareVersion
is an array containing elements of:
FirmwareVersion[{item}].ComponentName Member of PCIeDevice.v1_5_0.PCIeDevice
Description | Name of GPU cores |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
FirmwareVersion[{item}].VersionString Member of PCIeDevice.v1_5_0.PCIeDevice
Description | Version string of GPU cores |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
PCIeFunctions
The link to the collection of PCIe functions associated with this PCIe device.
PCIeFunctions is a link ("@odata.id": URI
) to another resource.
PCIeInterface
PCIeInterface.LanesInUse Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The number of PCIe lanes in use by this device. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PCIeInterface.MaxLanes Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The number of PCIe lanes supported by this device. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PCIeInterface.MaxPCIeType Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The highest version of the PCIe specification supported by this device. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Gen1 |
A PCIe v1.0 slot. |
Gen2 |
A PCIe v2.0 slot. |
Gen3 |
A PCIe v3.0 slot. |
Gen4 |
A PCIe v4.0 slot. |
Gen5 |
A PCIe v5.0 slot. |
PCIeInterface.PCIeType Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The version of the PCIe specification in use by this device. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Gen1 |
A PCIe v1.0 slot. |
Gen2 |
A PCIe v2.0 slot. |
Gen3 |
A PCIe v3.0 slot. |
Gen4 |
A PCIe v4.0 slot. |
Gen5 |
A PCIe v5.0 slot. |
PartNumber
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The part number for this PCIe device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SKU
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The SKU for this PCIe device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SerialNumber
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The serial number for this PCIe device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of PCIeDevice.v1_5_0.PCIeDevice See the Redfish standard schema and specification for information on common Status object.
PCIeDeviceCollection.PCIeDeviceCollection
@odata.type: "#PCIeDeviceCollection.PCIeDeviceCollection"
The collection of PCIeDevice Resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/pciedevices |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
PCIeDevice |
Members (array)
Member of PCIeDeviceCollection.PCIeDeviceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of PCIeDeviceCollection.PCIeDeviceCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of PCIeDeviceCollection.PCIeDeviceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PCIeFunction.v1_2_3.PCIeFunction
@odata.type: "#PCIeFunction.v1_2_3.PCIeFunction"
The schema definition for the PCIeFunction Resource. It represents the properties of a PCIeFunction attached to a System.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/pciedevices/{item}/pciefunctions/{item} |
GET |
ClassCode
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The Class Code of this PCIe function. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
DeviceClass
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The class for this PCIe function. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
UnclassifiedDevice |
An unclassified device. |
MassStorageController |
A mass storage controller. |
NetworkController |
A network controller. |
DisplayController |
A display controller. |
MultimediaController |
A multimedia controller. |
MemoryController |
A memory controller. |
Bridge |
A bridge. |
CommunicationController |
A communication controller. |
GenericSystemPeripheral |
A generic system peripheral. |
InputDeviceController |
An input device controller. |
DockingStation |
A docking station. |
Processor |
A processor. |
SerialBusController |
A serial bus controller. |
WirelessController |
A wireless controller. |
IntelligentController |
An intelligent controller. |
SatelliteCommunicationsController |
A satellite communications controller. |
EncryptionController |
An encryption controller. |
SignalProcessingController |
A signal processing controller. |
ProcessingAccelerators |
A processing accelerators. |
NonEssentialInstrumentation |
A non-essential instrumentation. |
Coprocessor |
A coprocessor. |
UnassignedClass |
An unassigned class. |
Other |
A other class. The function Device Class Id needs to be verified. |
DeviceId
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The Device ID of this PCIe function. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
FunctionId
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The PCIe Function Number. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
FunctionType
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The type of the PCIe function. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Physical |
A physical PCIe function. |
Virtual |
A virtual PCIe function. |
RevisionId
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The Revision ID of this PCIe function. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of PCIeFunction.v1_2_3.PCIeFunction See the Redfish standard schema and specification for information on common Status object.
SubsystemId
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The Subsystem ID of this PCIe function. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SubsystemVendorId
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The Subsystem Vendor ID of this PCIe function. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
VendorId
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The Vendor ID of this PCIe function. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PCIeFunctionCollection.PCIeFunctionCollection
@odata.type: "#PCIeFunctionCollection.PCIeFunctionCollection"
The collection of PCIeFunction Resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/pciedevices/{item}/pciefunctions |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
PCIeFunction |
Members (array)
Member of PCIeFunctionCollection.PCIeFunctionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of PCIeFunctionCollection.PCIeFunctionCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of PCIeFunctionCollection.PCIeFunctionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PCIeSlots.v1_3_0.PCIeSlots
@odata.type: "#PCIeSlots.v1_3_0.PCIeSlots"
The PCIeSlots schema describes PCIe slot properties.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/pcieslots |
GET |
Slots (array)
Member of PCIeSlots.v1_3_0.PCIeSlots
Slots
is an array containing elements of:
Slots[{item}].HotPluggable Member of PCIeSlots.v1_3_0.PCIeSlots
Description | An indication of whether this PCIe slot supports hotplug. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Slots[{item}].Lanes Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The number of PCIe lanes supported by this slot. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Slots[{item}].Location Slots[{item}].Location.PartLocation Slots[{item}].Location.PartLocation.LocationOrdinalValue Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The number that represents the location of the part. If LocationType is slot and this unit is in slot 2, the LocationOrdinalValue is 2. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Slots[{item}].Location.PartLocation.LocationType Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The location types for PartLocation. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Slot |
The slot as the type of location. |
Bay |
The bay as the type of location. |
Connector |
The connector as the type of location. |
Socket |
The socket as the type of location. |
Embedded |
Embedded within a part. |
Slots[{item}].Location.PartLocation.Orientation Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The orientation for the ordering of the part location ordinal value. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
FrontToBack |
The ordering for LocationOrdinalValue is front to back. |
BackToFront |
The ordering for the LocationOrdinalValue is back to front. |
TopToBottom |
The ordering for the LocationOrdinalValue is top to bottom. |
BottomToTop |
The ordering for LocationOrdinalValue is bottom to top. |
LeftToRight |
The ordering for the LocationOrdinalValue is left to right. |
RightToLeft |
The ordering for the LocationOrdinalValue is right to left. |
Slots[{item}].Location.PartLocation.Reference Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The reference area for the location of the part. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Top |
The part is in the top of the unit. |
Bottom |
The part is in the bottom of the unit. |
Front |
The part is in the front of the unit. |
Rear |
The part is in the rear of the unit. |
Left |
The part is on the left side of of the unit. |
Right |
The part is on the right side of the unit. |
Middle |
The part is in the middle of the unit. |
Slots[{item}].Location.PartLocation.ServiceLabel Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The label of the part location, such as a silk-screened name or a printed label. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Slots[{item}].Location.Placement Slots[{item}].Location.Placement.AdditionalInfo Member of PCIeSlots.v1_3_0.PCIeSlots
Description | Area designation or other additional info. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Slots[{item}].Location.Placement.Rack Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The name of a rack location within a row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Slots[{item}].Location.Placement.RackOffset Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The vertical location of the item, in terms of RackOffsetUnits. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Slots[{item}].Location.Placement.RackOffsetUnits Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The type of rack unit in use. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OpenU |
A rack unit that is equal to 48 mm (1.89 in). |
EIA_310 |
A rack unit that is equal to 1.75 in (44.45 mm). |
Slots[{item}].Location.Placement.Row Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The name of the row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Slots[{item}].PCIeType Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The PCIe specification supported by this slot. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Gen1 |
A PCIe v1.0 slot. |
Gen2 |
A PCIe v2.0 slot. |
Gen3 |
A PCIe v3.0 slot. |
Gen4 |
A PCIe v4.0 slot. |
Gen5 |
A PCIe v5.0 slot. |
Slots[{item}].SlotType Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The PCIe slot type for this slot. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
FullLength |
Full-Length PCIe slot. |
HalfLength |
Half-Length PCIe slot. |
LowProfile |
Low-Profile or Slim PCIe slot. |
Mini |
Mini PCIe slot. |
M2 |
PCIe M.2 slot. |
OEM |
An OEM-specific slot. |
OCP3Small |
Open Compute Project 3.0 small form factor slot. |
OCP3Large |
Open Compute Project 3.0 large form factor slot. |
U2 |
PCIe U.2 slot or bay |
Slots[{item}].Status Member of PCIeSlots.v1_3_0.PCIeSlots See the Redfish standard schema and specification for information on common Status object.
Port.v1_6_1.Port
@odata.type: "#Port.v1_6_1.Port"
A Port represents a discrete physical port capable of connecting to a network.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters/{item}/ports/{item} |
GET POST PATCH |
/redfish/v1/chassis/{item}/networkadapters/{item}/ports/{item}/settings |
GET PATCH |
/redfish/v1/systems/{item}/networkinterfaces/{item}/ports/{item} |
GET POST PATCH |
/redfish/v1/systems/{item}/networkinterfaces/{item}/ports/{item}/settings |
GET PATCH |
/redfish/v1/systems/{item}/storage/{item}/controllers/{item}/ports/{item} |
GET PATCH |
/redfish/v1/systems/{item}/storage/{item}/storagecontrollers/{item}/ports/{item} |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Port |
@Redfish.Settings
Member of Port.v1_6_1.Port See the Redfish standard schema and specification for information on common @Redfish properties.
ActiveWidth
Member of Port.v1_6_1.Port
Description | The number of active lanes for this interface. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CapableProtocolVersions (array)
Member of Port.v1_6_1.Port
CapableProtocolVersions
is an array containing elements of:
CapableProtocolVersions[{item}] Member of Port.v1_6_1.Port
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
CurrentProtocolVersion
Member of Port.v1_6_1.Port
Description | The protocol version being sent over this port. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
CurrentSpeedGbps
Member of Port.v1_6_1.Port
Description | The current speed of this port. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Enabled
Member of Port.v1_6_1.Port
Description | An indication of whether this port is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Ethernet
Ethernet.AssociatedMACAddresses (array)
Member of Port.v1_6_1.Port
AssociatedMACAddresses
is an array containing elements of:
AssociatedMACAddresses[{item}] Member of Port.v1_6_1.Port
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Ethernet.EEEEnabled Member of Port.v1_6_1.Port
Description | Indicates whether IEEE 802.3az Energy-Efficient Ethernet (EEE) is enabled on this port. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.FlowControlConfiguration Member of Port.v1_6_1.Port
Description | The locally configured 802.3x flow control setting for this port. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
None |
No IEEE 802.3x flow control is enabled on this port. |
TX |
IEEE 802.3x flow control may be initiated by this station. |
RX |
IEEE 802.3x flow control may be initiated by the link partner. |
TX_RX |
IEEE 802.3x flow control may be initiated by this station or the link partner. |
Ethernet.FlowControlStatus Member of Port.v1_6_1.Port
Description | The 802.3x flow control behavior negotiated with the link partner for this port. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
None |
No IEEE 802.3x flow control is enabled on this port. |
TX |
IEEE 802.3x flow control may be initiated by this station. |
RX |
IEEE 802.3x flow control may be initiated by the link partner. |
TX_RX |
IEEE 802.3x flow control may be initiated by this station or the link partner. |
Ethernet.LLDPEnabled Member of Port.v1_6_1.Port
Description | Enable/disable LLDP for this port. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.LLDPReceive Ethernet.LLDPReceive.ChassisId Member of Port.v1_6_1.Port
Description | Link Layer Data Protocol (LLDP) chassis ID received from the remote partner across this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Ethernet.LLDPReceive.ChassisIdSubtype Member of Port.v1_6_1.Port
Description | The type of identifier used for the chassis ID received from the remote partner across this link. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in RFC4133. |
IfAlias |
Interface alias, based on the ifAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in RFC4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the ifName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
NotTransmitted |
No data to be sent to/received from remote partner. |
Ethernet.LLDPReceive.ManagementAddressIPv4 Member of Port.v1_6_1.Port
Description | The IPv4 management address received from the remote partner across this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Ethernet.LLDPReceive.ManagementAddressIPv6 Member of Port.v1_6_1.Port
Description | The IPv6 management address received from the remote partner across this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Ethernet.LLDPReceive.ManagementAddressMAC Member of Port.v1_6_1.Port
Description | The management MAC address received from the remote partner across this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Ethernet.LLDPReceive.ManagementVlanId Member of Port.v1_6_1.Port
Description | The management VLAN ID received from the remote partner across this link. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Ethernet.LLDPReceive.PortId Member of Port.v1_6_1.Port
Description | A colon delimited string of hexadecimal octets identifying a port. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Ethernet.LLDPReceive.PortIdSubtype Member of Port.v1_6_1.Port
Description | The port ID subtype received from the remote partner across this link. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in RFC4133. |
IfAlias |
Interface alias, based on the ifAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in RFC4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the ifName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
NotTransmitted |
No data to be sent to/received from remote partner. |
Ethernet.LLDPTransmit Ethernet.LLDPTransmit.ChassisId Member of Port.v1_6_1.Port
Description | Link Layer Data Protocol (LLDP) chassis ID. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.LLDPTransmit.ChassisIdSubtype Member of Port.v1_6_1.Port
Description | The type of identifier used for the chassis ID. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in RFC4133. |
IfAlias |
Interface alias, based on the ifAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in RFC4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the ifName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
NotTransmitted |
No data to be sent to/received from remote partner. |
Ethernet.LLDPTransmit.ManagementAddressIPv4 Member of Port.v1_6_1.Port
Description | The IPv4 management address to be transmitted from this endpoint. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.LLDPTransmit.ManagementAddressIPv6 Member of Port.v1_6_1.Port
Description | The IPv6 management address to be transmitted from this endpoint. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.LLDPTransmit.ManagementAddressMAC Member of Port.v1_6_1.Port
Description | The management MAC address to be transmitted from this endpoint. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.LLDPTransmit.ManagementVlanId Member of Port.v1_6_1.Port
Description | The management VLAN ID to be transmitted from this endpoint. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.LLDPTransmit.PortId Member of Port.v1_6_1.Port
Description | A colon delimited string of hexadecimal octets identifying a port to be transmitted from this endpoint. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.LLDPTransmit.PortIdSubtype Member of Port.v1_6_1.Port
Description | The port ID subtype to be transmitted from this endpoint. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in RFC4133. |
IfAlias |
Interface alias, based on the ifAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in RFC4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the ifName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
NotTransmitted |
No data to be sent to/received from remote partner. |
Ethernet.WakeOnLANEnabled Member of Port.v1_6_1.Port
Description | Indicates whether Wake on LAN (WoL) is enabled on this port. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
FibreChannel
FibreChannel.AssociatedWorldWideNames (array)
Member of Port.v1_6_1.Port
AssociatedWorldWideNames
is an array containing elements of:
AssociatedWorldWideNames[{item}] Member of Port.v1_6_1.Port
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
FibreChannel.FabricName Member of Port.v1_6_1.Port
Description | The Fibre Channel Fabric Name provided by the switch. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
FibreChannel.NumberDiscoveredRemotePorts Member of Port.v1_6_1.Port
Description | The number of ports not on the associated device that the associated device has discovered through this port. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
FibreChannel.PortConnectionType Member of Port.v1_6_1.Port
Description | The connection type of this port. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NotConnected |
This port is not connected. |
NPort |
This port connects through an N-Port to a switch. |
PointToPoint |
This port connects in a Point-to-point configuration. |
PrivateLoop |
This port connects in a private loop configuration. |
PublicLoop |
This port connects in a public configuration. |
Generic |
This port connection type is a generic fabric port. |
ExtenderFabric |
This port connection type is an extender fabric port. |
FPort |
This port connection type is a fabric port. |
EPort |
This port connection type is an extender fabric port. |
TEPort |
This port connection type is an trunking extender fabric port. |
NPPort |
This port connection type is a proxy N port for N-Port virtualization. |
GPort |
This port connection type is a generic fabric port. |
NLPort |
This port connects in a node loop configuration. |
FLPort |
This port connects in a fabric loop configuration. |
EXPort |
This port connection type is an external fabric port. |
UPort |
This port connection type is unassigned. |
DPort |
This port connection type is a diagnostic port. |
FunctionMaxBandwidth (array)
Member of Port.v1_6_1.Port
FunctionMaxBandwidth
is an array containing elements of:
FunctionMaxBandwidth[{item}].AllocationPercent Member of Port.v1_6_1.Port
Description | The maximum bandwidth allocation percentage allocated to the corresponding network device function instance. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
FunctionMaxBandwidth[{item}].NetworkDeviceFunction
The link to the network device function associated with this bandwidth setting of this network port.
NetworkDeviceFunction is a link ("@odata.id": URI
) to another resource.
FunctionMinBandwidth (array)
Member of Port.v1_6_1.Port
FunctionMinBandwidth
is an array containing elements of:
FunctionMinBandwidth[{item}].AllocationPercent Member of Port.v1_6_1.Port
Description | The minimum bandwidth allocation percentage allocated to the corresponding network device function instance. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
FunctionMinBandwidth[{item}].NetworkDeviceFunction
The link to the network device function associated with this bandwidth setting of this network port.
NetworkDeviceFunction is a link ("@odata.id": URI
) to another resource.
InterfaceEnabled
Member of Port.v1_6_1.Port
Description | An indication of whether the interface is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
LinkConfiguration (array)
Member of Port.v1_6_1.Port
LinkConfiguration
is an array containing elements of:
LinkConfiguration[{item}].AutoSpeedNegotiationCapable Member of Port.v1_6_1.Port
Description | An indication of whether the port is capable of autonegotiating speed. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
LinkConfiguration[{item}].AutoSpeedNegotiationEnabled Member of Port.v1_6_1.Port
Description | Controls whether this port is configured to enable autonegotiating speed. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
LinkConfiguration[{item}].CapableLinkSpeedGbps (array)
Member of Port.v1_6_1.Port
CapableLinkSpeedGbps
is an array containing elements of:
CapableLinkSpeedGbps[{item}] Member of Port.v1_6_1.Port
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
LinkConfiguration[{item}].ConfiguredNetworkLinks (array)
Member of Port.v1_6_1.Port
ConfiguredNetworkLinks
is an array containing elements of:
ConfiguredNetworkLinks[{item}].ConfiguredLinkSpeedGbps Member of Port.v1_6_1.Port
Description | The link speed per lane this port is configured to use for autonegotiation. |
Type | number or null |
Read Only | False |
Added | iLO6 1.05 |
ConfiguredNetworkLinks[{item}].ConfiguredWidth Member of Port.v1_6_1.Port
Description | The link width this port is configured to use for autonegotiation in conjunction with the link speed. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
LinkNetworkTechnology
Member of Port.v1_6_1.Port
Description | The link network technology capabilities of this port. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Ethernet |
The port is capable of connecting to an Ethernet network. |
InfiniBand |
The port is capable of connecting to an InfiniBand network. |
FibreChannel |
The port is capable of connecting to a Fibre Channel network. |
GenZ |
The port is capable of connecting to a Gen-Z fabric. |
LinkState
Member of Port.v1_6_1.Port
Description | The desired link state for this interface. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
This link is enabled. |
Disabled |
This link is disabled. |
LinkStatus
Member of Port.v1_6_1.Port
Description | The desired link status for this interface. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
LinkUp |
This link on this interface is up. |
Starting |
This link on this interface is starting. A physical link has been established, but the port is not able to transfer data. |
Training |
This physical link on this interface is training. |
LinkDown |
The link on this interface is down. |
NoLink |
No physical link detected on this interface. |
LinkTransitionIndicator
Member of Port.v1_6_1.Port
Description | The number of link state transitions for this interface. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Location
Location.PartLocation Location.PartLocation.LocationOrdinalValue Member of Port.v1_6_1.Port
Description | The number that represents the location of the part. If LocationType is slot and this unit is in slot 2, the LocationOrdinalValue is 2. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Location.PartLocation.LocationType Member of Port.v1_6_1.Port
Description | The location types for PartLocation. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Slot |
The slot as the type of location. |
Bay |
The bay as the type of location. |
Connector |
The connector as the type of location. |
Socket |
The socket as the type of location. |
Embedded |
Embedded within a part. |
Location.PartLocation.Orientation Member of Port.v1_6_1.Port
Description | The orientation for the ordering of the part location ordinal value. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
FrontToBack |
The ordering for LocationOrdinalValue is front to back. |
BackToFront |
The ordering for the LocationOrdinalValue is back to front. |
TopToBottom |
The ordering for the LocationOrdinalValue is top to bottom. |
BottomToTop |
The ordering for LocationOrdinalValue is bottom to top. |
LeftToRight |
The ordering for the LocationOrdinalValue is left to right. |
RightToLeft |
The ordering for the LocationOrdinalValue is right to left. |
Location.PartLocation.Reference Member of Port.v1_6_1.Port
Description | The reference area for the location of the part. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Top |
The part is in the top of the unit. |
Bottom |
The part is in the bottom of the unit. |
Front |
The part is in the front of the unit. |
Rear |
The part is in the rear of the unit. |
Left |
The part is on the left side of of the unit. |
Right |
The part is on the right side of the unit. |
Middle |
The part is in the middle of the unit. |
Location.PartLocation.ServiceLabel Member of Port.v1_6_1.Port
Description | The label of the part location, such as a silk-screened name or a printed label. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Location.Placement Location.Placement.AdditionalInfo Member of Port.v1_6_1.Port
Description | Area designation or other additional info. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Location.Placement.Rack Member of Port.v1_6_1.Port
Description | The name of a rack location within a row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Location.Placement.RackOffset Member of Port.v1_6_1.Port
Description | The vertical location of the item, in terms of RackOffsetUnits. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Location.Placement.RackOffsetUnits Member of Port.v1_6_1.Port
Description | The type of rack unit in use. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OpenU |
A rack unit that is equal to 48 mm (1.89 in). |
EIA_310 |
A rack unit that is equal to 1.75 in (44.45 mm). |
Location.Placement.Row Member of Port.v1_6_1.Port
Description | The name of the row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
LocationIndicatorActive
Member of Port.v1_6_1.Port
Description | An indicator allowing an operator to physically locate this resource. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
MaxFrameSize
Member of Port.v1_6_1.Port
Description | The maximum frame size supported by the port. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MaxSpeedGbps
Member of Port.v1_6_1.Port
Description | The maximum speed of this port as currently configured. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.AutoNegotiationCapable
Member of Port.v1_6_1.Port
Description | Indicates the ability of this network port to autonegotiate link speed. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ConfiguredNetworkLinks (array)
Member of Port.v1_6_1.Port
ConfiguredNetworkLinks
is an array containing elements of:
ConfiguredNetworkLinks[{item}].ConfiguredLinkSpeedGbps Member of Port.v1_6_1.Port
Description | The link speed per lane this port is configured to use for autonegotiation. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
ConfiguredNetworkLinks[{item}].ConfiguredWidth Member of Port.v1_6_1.Port
Description | The number of lanes this port is configured to use for autonegotiation. If this property is omitted, the lane count shall default to one. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.EvbData
Oem.Hpe.EvbData.Receiving Oem.Hpe.EvbData.Receiving.CdcpActive Member of Port.v1_6_1.Port
Description | True if a currently active IEEE 802.1Qbg CDCP TLV has been received from the link partner. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelActive Member of Port.v1_6_1.Port
Description | A currently unexpired HPE Channel Link Control or HPE Channel Description TLV has been received from the link partner. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelDescriptionLocalSequenceNumber Member of Port.v1_6_1.Port
Description | The link partner’s HPE Channel Description sequence number that was last successfully received and processed. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelDescriptionRemoteSequenceNumber Member of Port.v1_6_1.Port
Description | The last HPE Channel Decsription sequence number sent on this link that was successfully received and processed by the link partner. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelDescriptionSubtype Member of Port.v1_6_1.Port
Description | The header subtype field of the last received HPE Channel Description TLV. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelLinkControlLocalSequenceNumber Member of Port.v1_6_1.Port
Description | The link partner’s HPE Channel Link Control sequence number that was last successfully received and processed. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelLinkControlMCEnable Member of Port.v1_6_1.Port
Description | The Feature Indicators field, Management Controller (MC) Channel (SCID 4094) enabled state in the HPE CLC TLV being received from the link partner on this port. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelLinkControlRemoteSequenceNumber Member of Port.v1_6_1.Port
Description | The last HPE Channel Link control sequence number sent on this link that was successfully received and processed by the link partner. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelLinkControlSubtype Member of Port.v1_6_1.Port
Description | The header subtype field of the last received HPE Channel Link Control TLV. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.Role Member of Port.v1_6_1.Port
Description | The link partner’s IEEE 802.1Qbg operating role. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
bridge |
Indicates the link partner is operating as a Bridge. |
station |
Indicates the link partner is operating as a Station. |
Oem.Hpe.EvbData.Receiving.SChannelAssignments (array)
Member of Port.v1_6_1.Port
SChannelAssignments
is an array containing elements of:
SChannelAssignments[{item}].Scid Member of Port.v1_6_1.Port
Description | SCID value for this |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
SChannelAssignments[{item}].Svid Member of Port.v1_6_1.Port
Description | SVID assignment value for this |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.SChannelMaxCount Member of Port.v1_6_1.Port
Description | Indicates the number of S-Channels the link partner can support on this physical link. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.SChannelsSupported Member of Port.v1_6_1.Port
Description | When true this link supports S-Channels. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.VirtualLinkStatusVector Member of Port.v1_6_1.Port
Description | A bit vector indicating S-Channel status received from the link partner, 1=up, 0=down. S-Channel status bits are ordered by SCID from lowest numbered (first) to highest (last). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting
Oem.Hpe.EvbData.Transmitting.ChannelDescriptionData (array)
Member of Port.v1_6_1.Port
ChannelDescriptionData
is an array containing elements of:
ChannelDescriptionData[{item}].Descriptor0BandwidthCirMbps Member of Port.v1_6_1.Port
Description | The bandwidth Commited Information Rate (CIR) for this S-Channel, in Mbps. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor0BandwidthPirMbps Member of Port.v1_6_1.Port
Description | The bandwidth Peak Information Rate (PIR) for this S-Channel, in Mbps. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor0ChannelTerminationType Member of Port.v1_6_1.Port
Description | Indicates the termination provided for this S-Channel. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
primary-physical |
This S-Channel is presented to the host OS as a primary PCI physical function. |
SR-IOV-virtual |
This S-Channel is presented to the host OS as a PCI SR-IOV virtual function. |
secondary-physical |
This S-Channel is presented to the host OS as a secondary PCI physical function, i.e. a PCI physical function behind a bridge on the device. |
vSwitch-port |
This S-Channel is mapped to a Virtual Switch port. |
NCSI-port |
This S-Channel is mapped to the NCSI internal port for management. |
ChannelDescriptionData[{item}].Descriptor0EthernetSupport Member of Port.v1_6_1.Port
Description | When true, this S-Channel supports Ethernet. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor0FCoESupport Member of Port.v1_6_1.Port
Description | When true, this S-Channel supports Fibre Channel over Ethernet (FCoE). |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor0PcpSupport Member of Port.v1_6_1.Port
Description | Indicates which IEEE 802.1Q Ethernet Priority Code Point (PCP) classes are supported on this S-Channel. When no PCPs are supported, the S-Channel makes no attempt to filter or control traffic class. A string of 1/0 characters indicating 1=enabled, 0=disabled. PCP classes are ordered from highest numbered 7 (first) to lowest 0 (last). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor0RoCEESupport Member of Port.v1_6_1.Port
Description | When true, this S-Channel supports RDMA over Converged Enhanced Ethernet (RoCEE). |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor0Scid Member of Port.v1_6_1.Port
Description | The S-Channel identifier for this Descriptor0 instance. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor0iSCSISupport Member of Port.v1_6_1.Port
Description | When true, this S-Channel supports Internet SCSI (iSCSI). |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor1ConnectionID Member of Port.v1_6_1.Port
Description | A unique S-Channel identifer in UUID format. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor1Scid Member of Port.v1_6_1.Port
Description | The S-Channel identifier for this Descriptor1 instance. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.ChannelDescriptionLocalSequenceNumber Member of Port.v1_6_1.Port
Description | This station’s channel discovery local sequence number which will be transmitted to the link partner on this port. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.ChannelDescriptionRemoteSequenceNumber Member of Port.v1_6_1.Port
Description | The link partner’s channel discovery local sequence number that was last successfully received and processed. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.ChannelDescriptorCount Member of Port.v1_6_1.Port
Description | The number of channel descriptor pairs being transmitted to the link partner on this port. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.ChannelLinkControlLocalSequenceNumber Member of Port.v1_6_1.Port
Description | This station’s channel link control local sequence number which will be transmitted to the link partner on this port. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.ChannelLinkControlMCEnable Member of Port.v1_6_1.Port
Description | The Feature Indicators field, Management Controller (MC) Channel (SCID 4094) enabled state in the HPE CLC TLV being transmitted to the link partner on this port. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.ChannelLinkControlRemoteSequenceNumber Member of Port.v1_6_1.Port
Description | The link partner’s channel link control local sequence number that was last successfully received and processed. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.Role Member of Port.v1_6_1.Port
Description | This port’s IEEE 802.1Qbg role being advertised on the link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
bridge |
Indicates this link is operating locally as a Bridge. |
station |
Indicates this link is operating locally as a Station. |
Oem.Hpe.EvbData.Transmitting.SChannelAssignments (array)
Member of Port.v1_6_1.Port
SChannelAssignments
is an array containing elements of:
SChannelAssignments[{item}].Scid Member of Port.v1_6_1.Port
Description | SCID value for this |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
SChannelAssignments[{item}].Svid Member of Port.v1_6_1.Port
Description | SVID assignment value for this |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.SChannelMaxCount Member of Port.v1_6_1.Port
Description | The Channel Capacity value being advertised to the link partner. It indicates the number of S-Channels this station can support on this physical link. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.SChannelsSupported Member of Port.v1_6_1.Port
Description | When true, indicates that this physical link has S-Channel capability. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.VirtualLinkStatusVector Member of Port.v1_6_1.Port
Description | A bit vector indicating S-Channel status being transmitted on this link, 1=up, 0=down. S-Channel status bits are ordered by SCID from lowest numbered (first) to highest (last). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData
Oem.Hpe.LldpData.Receiving Oem.Hpe.LldpData.Receiving.ChassisID Member of Port.v1_6_1.Port
Description | The LLDP chassis ID received from the link partner. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.ChassisIDSubtype Member of Port.v1_6_1.Port
Description | The IEEE 802.1AB-2009 chassis ID subtype received from the link partner. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133. |
IfAlias |
Interface alias, based on the IfAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in IETF RFC 4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the IfName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
Oem.Hpe.LldpData.Receiving.Dcb Oem.Hpe.LldpData.Receiving.Dcb.ApplicationPriorityReceived Member of Port.v1_6_1.Port
Description | True when an unexpired Data Center Bridging (DCB) Application Priority Table TLV has been received. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.ApplicationPriorityTable (array)
Member of Port.v1_6_1.Port
ApplicationPriorityTable
is an array containing elements of:
ApplicationPriorityTable[{item}].ApplicationPriority Member of Port.v1_6_1.Port
Description | Indicates which priority level is assigned for this application protocol. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
ApplicationPriorityTable[{item}].ApplicationProtocol Member of Port.v1_6_1.Port
Description | An integer value indicating application protocol identity, of the type described by DCBApplicationSelect. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
ApplicationPriorityTable[{item}].ApplicationSelect Member of Port.v1_6_1.Port
Description | Indentifies the type of the DCBApplicationProtocol property. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
reserved |
Reserved select value. |
default-Ethertype |
Default priority. Use when priority not otherwise specified. |
TCP-SCTP |
DCBApplicationProtocol value is a well known port over TCP or SCTP. |
UDP-DCCP |
DCBApplicationProtocol value is a well known port over UDP or DCCP. |
TCP-SCTP-UDP-DCCP |
DCBApplicationProtocol is a well known port over TCP, SCTP, SCTP, or DCCP. |
Oem.Hpe.LldpData.Receiving.Dcb.Ets
Oem.Hpe.LldpData.Receiving.Dcb.Ets.BandwidthAssignmentTable (array)
Member of Port.v1_6_1.Port
BandwidthAssignmentTable
is an array containing elements of:
BandwidthAssignmentTable[{item}] Member of Port.v1_6_1.Port
Description | One entry in the DCB ETS Traffic Class (TC) Bandwidth Assignment Table. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Ets.CreditBasedShaper Member of Port.v1_6_1.Port
Description | True if the link partner supports the Credit-based Shaper (CBS) transmmission selection algortithm. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Ets.MaximumTrafficClassCount Member of Port.v1_6_1.Port
Description | The maximum number of traffic classes supported by the link partner. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Ets.PriorityAssignmentTable (array)
Member of Port.v1_6_1.Port
PriorityAssignmentTable
is an array containing elements of:
PriorityAssignmentTable[{item}] Member of Port.v1_6_1.Port
Description | One entry in the DCB ETS Priority Assignment Table indicating this priority’s Traffic Class assignment. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Ets.TlvReceived Member of Port.v1_6_1.Port
Description | True when an unexpired DCB Enhanced Transmission Selection (ETS) TLV has been received. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Ets.TrafficSelectionAlgorithmTable (array)
Member of Port.v1_6_1.Port
TrafficSelectionAlgorithmTable
is an array containing elements of:
TrafficSelectionAlgorithmTable[{item}] Member of Port.v1_6_1.Port
Description | An assignment of a Traffic Selection Algorithm (TSA) to a traffic class. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
strict |
Strict priority algorithm. |
CBS |
Credit-Based Shaper algorithm. |
ETS |
Enhanced Traffic Selection algorithm. |
vendor |
Vendor specific algorithm for use with DCB. |
Oem.Hpe.LldpData.Receiving.Dcb.Ets.Willing Member of Port.v1_6_1.Port
Description | True if the link partner is willing to accept ETS configurations. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.LocalEqualRemote Member of Port.v1_6_1.Port
Description | True when the transmitted and received contents match for both DCB ETS and PFC TLVs. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Pfc Oem.Hpe.LldpData.Receiving.Dcb.Pfc.EnabledTrafficClasses Member of Port.v1_6_1.Port
Description | A bit string indicating which priority levels have PFC enabled, 1=enabled. PFC levels are bit ordered from 7 (first) to 0 (last). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Pfc.MacSecurityBypassCapability Member of Port.v1_6_1.Port
Description | True when the link partner has the ability to bypass MAC security in order to improve PFC responsiveness. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Pfc.MaximumTrafficClassCount Member of Port.v1_6_1.Port
Description | Indicates the maximum number of traffic classes that the link partner can simultaneously support. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Pfc.TlvReceived Member of Port.v1_6_1.Port
Description | True when an unexpired DCB Priority Flow Control (PFC) TLV has been received. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Pfc.Willing Member of Port.v1_6_1.Port
Description | True if the LLDP link partner is willing to accept PFC configurations. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Version Member of Port.v1_6_1.Port
Description | The DCB version supported by the link partner. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
unknown |
Unknown |
CEE |
Converged Enhanced Ethernet |
IEEE |
IEEE 802.1Q |
Oem.Hpe.LldpData.Receiving.ManagementAddress Member of Port.v1_6_1.Port
Description | The management address received from the link partner. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.ManagementAddressOID Member of Port.v1_6_1.Port
Description | An object identifier for the hardware or protocol entity associated with the management address. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.ManagementAddressReceived Member of Port.v1_6_1.Port
Description | True when a currently unexpired management address TLV has been received from the link partner. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.ManagementAddressType Member of Port.v1_6_1.Port
Description | The type of management address received from the link partner. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
IPv4 |
Type 1 (IP version 4). |
IPv6 |
Type 2 (IP version 6). |
all802 |
Type 6 (All 802 media plus Ethernet ‘canonical format’). |
Oem.Hpe.LldpData.Receiving.ManagementIFNumSubtype Member of Port.v1_6_1.Port
Description | Management interface number subtype. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
unknown |
Interface number is not known. |
ifIndex |
Interface number is based on the ifIndex MIB object. |
sysPortNum |
Interface number is based on the system port numbering convention. |
Oem.Hpe.LldpData.Receiving.ManagementIFNumber Member of Port.v1_6_1.Port
Description | Management interface number received from the link partner represented as a colon delimited string of hexadecimal octets. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.ManagementVlanReceived Member of Port.v1_6_1.Port
Description | True when a currently unexpired management address VID TLV has been received from the link partner. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.NearestBridgeTtlExpired Member of Port.v1_6_1.Port
Description | True when the LLDP PDU most recently received from the link partner has expired. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.PortDescription Member of Port.v1_6_1.Port
Description | The remote link partner’s port description. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.PortID Member of Port.v1_6_1.Port
Description | A colon delimited string of hexadecimal octets received from the link partner identifying its port. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.PortIDSubtype Member of Port.v1_6_1.Port
Description | The port ID subtype enumeration from IEEE 802.1AB-2009 Table 8-3, which indicates the format for the PortID property. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133. |
IfAlias |
Interface alias, based on the IfAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in IETF RFC 4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the IfName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
Oem.Hpe.LldpData.Receiving.SystemDescription Member of Port.v1_6_1.Port
Description | The system description received from the link partner. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Transmitting Oem.Hpe.LldpData.Transmitting.ChassisID Member of Port.v1_6_1.Port
Description | The Link Layer Data Protocol (LLDP) chassis ID being transmitted on this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Transmitting.ChassisIDSubtype Member of Port.v1_6_1.Port
Description | The IEEE 802.1AB-2009 chassis ID subtype being transmitted on this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133. |
IfAlias |
Interface alias, based on the IfAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in IETF RFC 4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the IfName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
Oem.Hpe.LldpData.Transmitting.ManagementAddresses (array)
Member of Port.v1_6_1.Port
ManagementAddresses
is an array containing elements of:
ManagementAddresses[{item}].ManagementIPAddress Member of Port.v1_6_1.Port
Description | A management address. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ManagementAddresses[{item}].ManagementIPAddressType Member of Port.v1_6_1.Port
Description | The IANA type of this management address. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
IPv4 |
Type 1 (IP version 4). |
IPv6 |
Type 2 (IP version 6). |
all802 |
Type 6 (All 802 media plus Ethernet ‘canonical format’). |
Oem.Hpe.LldpData.Transmitting.ManagementCvlanIDTransmitted Member of Port.v1_6_1.Port
Description | When true, indicates that a management CVLAN ID is being transmitted on this link. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Transmitting.PortDescription Member of Port.v1_6_1.Port
Description | An alphanumeric string describing this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Transmitting.PortID Member of Port.v1_6_1.Port
Description | A colon delimited string of hexadecimal octets identifying this port. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Transmitting.PortIDSubtype Member of Port.v1_6_1.Port
Description | The port ID subtype from IEEE 802.1AB-2009 Table 8-3. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133. |
IfAlias |
Interface alias, based on the IfAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in IETF RFC 4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the IfName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
Oem.Hpe.LldpData.Transmitting.SystemDescription Member of Port.v1_6_1.Port
Description | A textual description of this system. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PortDiagnosticEnableLocalLoopback
Member of Port.v1_6_1.Port
Description | When true, local loopback is active on this port. PortDiagnosticsEnabled must first be true in order to set this property to true. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.PortDiagnosticEnableRemoteLoopback
Member of Port.v1_6_1.Port
Description | When true, remote loopback is active on this port. PortDiagnosticsEnabled must first be true in order to set this property to true. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.PortDiagnosticLocalLoopbackCapable
Member of Port.v1_6_1.Port
Description | When true, the port has local loopback capability. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PortDiagnosticRemoteLoopbackCapable
Member of Port.v1_6_1.Port
Description | When true, the port has remote loopback capability. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PortDiagnosticsEnabled
Member of Port.v1_6_1.Port
Description | When true, diagnostic features are enabled on this port. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.VirtualFunctionAllocations (array)
Member of Port.v1_6_1.Port
VirtualFunctionAllocations
is an array containing elements of:
VirtualFunctionAllocations[{item}].NetworkDeviceFunction
The logical network device function to which this virtual function allocation applies.
NetworkDeviceFunction is a link ("@odata.id": URI
) to another resource.
VirtualFunctionAllocations[{item}].VirtualFunctionsAllocated Member of Port.v1_6_1.Port
Description | The number of virtual functions allocated to this logical network device function instance. |
Type | number or null |
Read Only | False |
Added | iLO6 1.05 |
PortId
Member of Port.v1_6_1.Port
Description | The label of this port on the physical package for this port. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PortMedium
Member of Port.v1_6_1.Port
Description | The physical connection medium for this port. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Electrical |
This port has an electrical cable connection. |
Optical |
This port has an optical cable connection. |
PortProtocol
Member of Port.v1_6_1.Port
Description | The protocol being sent over this port. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Ethernet |
Ethernet. |
FC |
Fibre Channel. |
FCoE |
Fibre Channel over Ethernet (FCoE). |
GenZ |
GenZ. |
InfiniBand |
InfiniBand. |
SAS |
Serial Attached SCSI. |
MultiProtocol |
Multiple Protocols. |
PCIe |
PCI Express. |
AHCI |
Advanced Host Controller Interface (AHCI). |
UHCI |
Universal Host Controller Interface (UHCI). |
SATA |
Serial AT Attachment. |
USB |
Universal Serial Bus (USB). |
NVMe |
Non-Volatile Memory Express (NVMe). |
iSCSI |
Internet SCSI. |
FCP |
Fibre Channel Protocol for SCSI. |
FICON |
FIbre CONnection (FICON). |
NVMeOverFabrics |
NVMe over Fabrics. |
SMB |
Server Message Block (SMB). Also known as the Common Internet File System (CIFS). |
NFSv3 |
Network File System (NFS) version 3. |
NFSv4 |
Network File System (NFS) version 4. |
HTTP |
Hypertext Transport Protocol (HTTP). |
HTTPS |
Hypertext Transfer Protocol Secure (HTTPS). |
FTP |
File Transfer Protocol (FTP). |
SFTP |
SSH File Transfer Protocol (SFTP). |
iWARP |
Internet Wide Area RDMA Protocol (iWARP). |
RoCE |
RDMA over Converged Ethernet Protocol. |
RoCEv2 |
RDMA over Converged Ethernet Protocol Version 2. |
I2C |
Inter-Integrated Circuit Bus. |
TCP |
Transmission Control Protocol (TCP). |
UDP |
User Datagram Protocol (UDP). |
TFTP |
Trivial File Transfer Protocol (TFTP). |
NVLink |
NVLink. |
OEM |
OEM-specific. |
DisplayPort |
DisplayPort. |
HDMI |
HDMI. |
VGA |
VGA. |
DVI |
DVI. |
PortType
Member of Port.v1_6_1.Port
Description | The type of this port. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
UpstreamPort |
This port connects to a host device. |
DownstreamPort |
This port connects to a target device. |
InterswitchPort |
This port connects to another switch. |
ManagementPort |
This port connects to a switch manager. |
BidirectionalPort |
This port connects to any type of device. |
UnconfiguredPort |
This port has not yet been configured. |
SignalDetected
Member of Port.v1_6_1.Port
Description | An indication of whether a signal is detected on this interface. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of Port.v1_6_1.Port See the Redfish standard schema and specification for information on common Status object.
Width
Member of Port.v1_6_1.Port
Description | The number of lanes, phys, or other physical transport links that this port contains. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Actions
Port.Reset Member of Port.v1_6_1.Port
Parameters:
target (string)
Link to invoke action
ResetValue (string)
Reset Port
Value | Description |
---|---|
GracefulRestart | Shut down gracefully and restart the system. |
GracefulShutdown | Shut down gracefully and power off. |
PowerCycle | Power cycle the unit. Behaves like a full power removal, followed by a power restore to the resource. |
On | Turn on the unit. |
ForceOff | Turn off the unit immediately (non-graceful shutdown). |
PushPowerButton | Simulate the pressing of the physical power button on this unit. |
ForceOn | Turn on the unit immediately. |
ForceRestart | Shut down immediately and non-gracefully and restart the system. |
Nmi | Generate a diagnostic interrupt, which is usually an NMI on x86 systems, to stop normal operations, complete diagnostic actions, and, typically, halt the system. |
PortCollection.PortCollection
@odata.type: "#PortCollection.PortCollection"
A Collection of Port resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters/{item}/ports |
GET |
/redfish/v1/systems/{item}/networkinterfaces/{item}/ports |
GET POST PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Port |
Members (array)
Member of PortCollection.PortCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of PortCollection.PortCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of PortCollection.PortCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Power.v1_3_0.Power
@odata.type: "#Power.v1_3_0.Power"
The Power resource describes the Power Metrics. It represents the properties for Power Consumption and Power Limiting.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Oem/Hpe/Links/FederatedGroupCapping |
HpeiLOFederatedGroupCapping |
Oem/Hpe/Links/PowerMeter |
HpePowerMeter |
Redundancy[]/RedundancySet[] |
Power |
Oem/Hpe/Links/FastPowerMeter |
HpePowerMeter |
Oem.Hpe.BatteryBackedUnits (array)
Member of Power.v1_3_0.Power
BatteryBackedUnits
is an array containing elements of:
BatteryBackedUnits[{item}].BBUStatus BatteryBackedUnits[{item}].BBUStatus.Health Member of Power.v1_3_0.Power
Description | This represents the health state of this resource in the absence of its dependent resources. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
BatteryBackedUnits[{item}].BBUStatus.HealthRollup Member of Power.v1_3_0.Power
Description | This represents the overall health state from the view of this resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
BatteryBackedUnits[{item}].BBUStatus.State Member of Power.v1_3_0.Power
Description | This indicates the known state of the resource, such as if it is enabled. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Enabled |
This function or resource has been enabled. |
Disabled |
This function or resource has been disabled. |
StandbyOffline |
This function or resource is enabled, but awaiting an external action to activate it. |
StandbySpare |
This function or resource is part of a redundancy set and is awaiting a failover or other external action to activate it. |
InTest |
This function or resource is undergoing testing. |
Starting |
This function or resource is starting. |
Absent |
This function or resource is not present or not detected. |
UnavailableOffline |
This function or resource is present but cannot be used. |
Deferring |
The element will not process any commands but will queue new requests. |
Quiesced |
The element is enabled but only processes a restricted set of commands. |
Updating |
The element is updating and may be unavailable or degraded. |
BatteryBackedUnits[{item}].BayNumber Member of Power.v1_3_0.Power
Description | Bay number of the battery backed unit. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].CapacityWatts Member of Power.v1_3_0.Power
Description | Total capacity (in Watts) of the battery backed unit. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].CutOffSetPointmAh Member of Power.v1_3_0.Power
Description | Cut off threshold (mAh) where battery backed unit stops supplying power to the server. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].FirmwareVersion Member of Power.v1_3_0.Power
Description | Firmware version of the battery backed unit. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].PercentCharge Member of Power.v1_3_0.Power
Description | Percentage charge remaining for the battery backed unit. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].RemainingCapacitymAh Member of Power.v1_3_0.Power
Description | Remaining capacity (mAh) of the battery backed unit. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].SerialNumber Member of Power.v1_3_0.Power
Description | Serial number of the battery backed unit. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].TimeToCutOffSeconds Member of Power.v1_3_0.Power
Description | Run time (in seconds) available with the battery backed unit until cut off. This is detected only when battery is charging or discharging, otherwise set to 0. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].TimeToFullChargeMinutes Member of Power.v1_3_0.Power
Description | Time required (in minutes) to fully charge the battery backed unit. This is detected only when battery is charging or discharging, otherwise set to 0. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].UsableCapacitymAh Member of Power.v1_3_0.Power
Description | Usable capacity (mAh) of the battery backed unit. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.BbuPowerSupply
Member of Power.v1_3_0.Power
Description | Battery Backup Unit Power Supply action determines what will occur when a server is running on battery power. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
DoNothing |
No action will be taken when a server switches to battery power. |
MomentaryPowerButtonPress |
Momentary virtual power button press which should shutdown host operating system when pressed. |
HostShutdown |
Shutdown message sent to host operating system with installed management software to initiate a shutdown. |
Oem.Hpe.BrownoutRecoveryEnabled
Member of Power.v1_3_0.Power
Description | When a brownout condition occurs in the server, this setting will determine if the server should recover from it. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.Domains (array)
Member of Power.v1_3_0.Power
Domains
is an array containing elements of:
Domains[{item}].DomainName Member of Power.v1_3_0.Power
Description | Power Supply Domain Name. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value |
---|
System |
GPU |
Domains[{item}].HighEfficiencyMode Member of Power.v1_3_0.Power
Description | The redundant power supply mode that will be used when redundant power supplies are configured. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value |
---|
Null |
Auto |
Balanced |
Even |
Odd |
NoSupport |
Domains[{item}].PowerSupplies (array)
Member of Power.v1_3_0.Power
PowerSupplies
is an array containing elements of:
PowerSupplies[{item}].@odata.id Member of Power.v1_3_0.Power
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Domains[{item}].PowerSupplyRedundancy Member of Power.v1_3_0.Power
Description | This indicates if the Power Supply is redundant or not. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
Redundant |
The power supplies are Redundant. |
NonRedundant |
The power supplies are not Redundant. |
FailedRedundant |
The Redundant power supply has failed. |
Unknown |
The Redundant state is unknown. |
Domains[{item}].Status Member of Power.v1_3_0.Power See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.FanPowerRequirement
Member of Power.v1_3_0.Power
Description | Cooling challenge bucket definition. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.FanPowerRequirementErrors
Member of Power.v1_3_0.Power
Description | Cooling challenge errors. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.FanPowerRequirementVersion
Member of Power.v1_3_0.Power
Description | Version of the Synergy cooling table bucket definitions. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.HasCpuPowerMetering
Member of Power.v1_3_0.Power
Description | Indicates if the system has CPU power metering. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.HasDimmPowerMetering
Member of Power.v1_3_0.Power
Description | Indicates if the system has DIMM power metering. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.HasGpuPowerMetering
Member of Power.v1_3_0.Power
Description | Indicates if the system has GPU power metering. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.HasPowerMetering
Member of Power.v1_3_0.Power
Description | Indicates if the system has power metering. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.HighEfficiencyMode
Member of Power.v1_3_0.Power
Description | The redundant power supply mode that will be used when redundant power supplies are configured. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Null |
Auto |
Balanced |
Even |
Odd |
NoSupport |
Oem.Hpe.MinimumSafelyAchievableCap
Member of Power.v1_3_0.Power
Description | Minimum Safely Achievable Cap is the lowest cap value that is safe for a group power manager to apply to a particular server. It can either be identical to or slightly greater than the 0 percent cap value calculated during ROM power burn. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.MinimumSafelyAchievableCapValid
Member of Power.v1_3_0.Power
Description | Indicates if the msac is valid. msac is valid only if this is true. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SNMPPowerThresholdAlert
Oem.Hpe.SNMPPowerThresholdAlert.DurationInMin Member of Power.v1_3_0.Power
Description | Sets the length of time, in minutes, that power consumption must remain above the warning threshold before an SNMP alert is triggered. The maximum duration is 240 minutes, and the duration must be a multiple of 5. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.SNMPPowerThresholdAlert.ThresholdWatts Member of Power.v1_3_0.Power
Description | Sets the power consumption threshold (watts). If power consumption exceeds this value for the specified time duration, an SNMP alert is triggered. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.SNMPPowerThresholdAlert.Trigger Member of Power.v1_3_0.Power
Description | Trigger determines whether alerts are based on peak power consumption, average power consumption, or if they are disabled. Trigger property can only be enabled if the ThresholdWatts and DurationInMin values are specified/configured. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Disabled |
AveragePowerConsumption |
PeakPowerConsumption |
PowerControl (array)
Member of Power.v1_3_0.Power
PowerControl
is an array containing elements of:
PowerControl[{item}].@odata.id Member of Power.v1_3_0.Power
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
PowerControl[{item}].MemberId Member of Power.v1_3_0.Power
Description | This is the identifier for the member within the collection. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerAllocatedWatts Member of Power.v1_3_0.Power
Description | The total amount of power that has been allocated (or budegeted)to chassis resources. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerAvailableWatts Member of Power.v1_3_0.Power
Description | The amount of power not already budgeted and therefore available for additional allocation. (powerCapacity - powerAllocated). This indicates how much reserve power capacity is left. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerCapacityWatts Member of Power.v1_3_0.Power
Description | The total amount of power available to the chassis for allocation. This may the power supply capacity, or power budget assigned to the chassis from an up-stream chassis. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerConsumedWatts Member of Power.v1_3_0.Power
Description | The actual power being consumed by the chassis. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerLimit PowerControl[{item}].PowerLimit.CorrectionInMs Member of Power.v1_3_0.Power
Description | The time required for the limiting process to reduce power consumption to below the limit. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerLimit.LimitException Member of Power.v1_3_0.Power
Description | The action that is taken if the power cannot be maintained below the LimitInWatts. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NoAction |
Take no action when the limit is exceeded. |
HardPowerOff |
Turn the power off immediately when the limit is exceeded. |
LogEventOnly |
Log an event when the limit is exceeded, but take no further action. |
Oem |
Take an OEM-defined action. |
PowerControl[{item}].PowerLimit.LimitInWatts Member of Power.v1_3_0.Power
Description | The Power limit in watts. Set to null to disable power capping. |
Type | number or null |
Read Only | False |
Added | iLO6 1.05 |
PowerControl[{item}].PowerMetrics PowerControl[{item}].PowerMetrics.AverageConsumedWatts Member of Power.v1_3_0.Power
Description | The average power level over the measurement window (the last IntervalInMin minutes). |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerMetrics.IntervalInMin Member of Power.v1_3_0.Power
Description | The time interval (or window) in which the PowerMetrics are measured over. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerMetrics.MaxConsumedWatts Member of Power.v1_3_0.Power
Description | The highest power consumption level that has occured over the measurement window (the last IntervalInMin minutes). |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerMetrics.MinConsumedWatts Member of Power.v1_3_0.Power
Description | The lowest power consumption level over the measurement window (the last IntervalInMin minutes). |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerRequestedWatts Member of Power.v1_3_0.Power
Description | The potential power that the chassis resources are requesting which may be higher than the current level being consumed since requested power includes budget that the chassis resource wants for future use. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].RelatedItem (array)
Member of Power.v1_3_0.Power
RelatedItem
is an array containing elements of:
RelatedItem[{item}].@odata.id Member of Power.v1_3_0.Power
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
PowerControl[{item}].Status Member of Power.v1_3_0.Power See the Redfish standard schema and specification for information on common Status object.
PowerSupplies (array)
Member of Power.v1_3_0.Power
PowerSupplies
is an array containing elements of:
PowerSupplies[{item}].@odata.id Member of Power.v1_3_0.Power
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
PowerSupplies[{item}].FirmwareVersion Member of Power.v1_3_0.Power
Description | The firmware version for this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].LastPowerOutputWatts Member of Power.v1_3_0.Power
Description | The average power output of this Power Supply |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].LineInputVoltage Member of Power.v1_3_0.Power
Description | The line input voltage at which the Power Supply is operating |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].LineInputVoltageType Member of Power.v1_3_0.Power
Description | The line voltage type supported as an input to this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The power supply line input voltage type cannot be determined. |
ACLowLine |
100-127V AC input. |
ACMidLine |
200-240V AC input. |
ACHighLine |
277V AC input. |
DCNeg48V |
-48V DC input. |
HighVoltageDC |
High Voltage DC input (380V). |
PowerSupplies[{item}].Manufacturer Member of Power.v1_3_0.Power
Description | This is the manufacturer of this power supply. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].MemberId Member of Power.v1_3_0.Power
Description | This is the identifier for the member within the collection. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Model Member of Power.v1_3_0.Power
Description | The model number for this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.AveragePowerOutputWatts Member of Power.v1_3_0.Power
Description | The latest observed average power being drawn by the power supply (Watts). This is usually updated every 10 seconds but the period can vary in some circumstances. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.BayNumber Member of Power.v1_3_0.Power
Description | The power supply bay number. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.Domain Member of Power.v1_3_0.Power
Description | This indicates the domain of the specific power supply. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value |
---|
System |
GPU |
PowerSupplies[{item}].Oem.Hpe.HotplugCapable Member of Power.v1_3_0.Power
Description | If true, this power supply (and power supply bay) is capable of being hot-plugged. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.MaxPowerOutputWatts Member of Power.v1_3_0.Power
Description | The latest observed maximum output power being drawn by the power supply (Watts). This is usually updated every 10 seconds but the period can vary in some circumstances. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.Mismatched Member of Power.v1_3_0.Power
Description | If true, this power supply is mismatched with others in the system. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.PowerSupplyStatus PowerSupplies[{item}].Oem.Hpe.PowerSupplyStatus.State Member of Power.v1_3_0.Power
Description | Indicates the known state of the resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Unknown |
Ok |
Degraded |
Failed |
OverVoltage |
OverCurrent |
OverTemperature |
ACPowerLost |
FanFailure |
WarningHighInputVoltage |
WarningLowInputVoltage |
WarningHighOutputVoltage |
WarningLowOutputVoltage |
WarningInletTemperature |
WarningInternalTemperature |
WarningHighAuxiliaryVoltage |
WarningLowAuxiliaryVoltage |
PowerSupplyMismatch |
GoodInStandby |
PowerSupplies[{item}].Oem.Hpe.iPDU PowerSupplies[{item}].Oem.Hpe.iPDU.IPAddress Member of Power.v1_3_0.Power
Description | The IP address of the iPDU connected to this power supply. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.iPDU.MacAddress Member of Power.v1_3_0.Power
Description | The Ethernet MAC address of the iPDU connected to this power supply. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.iPDU.Model Member of Power.v1_3_0.Power
Description | The model number of the iPDU connected to this power supply. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.iPDU.SerialNumber Member of Power.v1_3_0.Power
Description | The serial number of the iPDU connected to this power supply. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.iPDU.iPDUStatus PowerSupplies[{item}].Oem.Hpe.iPDU.iPDUStatus.State Member of Power.v1_3_0.Power
Description | Indicates the known state of the resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Unknown |
Ok |
Degraded |
Failed |
OverVoltage |
OverCurrent |
OverTemperature |
ACPowerLost |
FanFailure |
WarningHighInputVoltage |
WarningLowInputVoltage |
WarningHighOutputVoltage |
WarningLowOutputVoltage |
WarningInletTemperature |
WarningInternalTemperature |
WarningHighAuxiliaryVoltage |
WarningLowAuxiliaryVoltage |
PowerSupplyMismatch |
GoodInStandby |
PowerSupplies[{item}].Oem.Hpe.iPDUCapable Member of Power.v1_3_0.Power
Description | If true, this power supply is capable of being connected to an iPDUs. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].PartNumber Member of Power.v1_3_0.Power
Description | The part number for this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].PowerCapacityWatts Member of Power.v1_3_0.Power
Description | The maximum capacity of this Power Supply |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].PowerSupplyType Member of Power.v1_3_0.Power
Description | The Power Supply type (AC or DC) |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The power supply type cannot be determined |
AC |
Alternating Current (AC) power supply |
DC |
Direct Current (DC) power supply |
PowerSupplies[{item}].Redundancy Member of Power.v1_3_0.Power See the Redfish standard schema and specification for information on common Redundancy object.
PowerSupplies[{item}].RelatedItem (array)
Member of Power.v1_3_0.Power
RelatedItem
is an array containing elements of:
RelatedItem[{item}].@odata.id Member of Power.v1_3_0.Power
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
PowerSupplies[{item}].SerialNumber Member of Power.v1_3_0.Power
Description | The serial number for this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].SparePartNumber Member of Power.v1_3_0.Power
Description | The spare part number for this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Status Member of Power.v1_3_0.Power See the Redfish standard schema and specification for information on common Status object.
Redundancy
Member of Power.v1_3_0.Power See the Redfish standard schema and specification for information on common Redundancy object.
Status
Member of Power.v1_3_0.Power See the Redfish standard schema and specification for information on common Status object.
Processor.v1_7_2.Processor
@odata.type: "#Processor.v1_7_2.Processor"
The Processor resource describes the Processor resource. It represents the properties of a processor attached to a System.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/processors/{item} |
GET |
InstructionSet
Member of Processor.v1_7_2.Processor
Description | The instruction set of the processor |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
x86 |
x86 32-bit |
x86-64 |
x86 64-bit |
IA-64 |
Intel IA-64 |
ARM-A32 |
ARM 32-bit |
ARM-A64 |
ARM 64-bit |
MIPS32 |
MIPS 32-bit |
MIPS64 |
MIPS 64-bit |
OEM |
OEM-defined |
Manufacturer
Member of Processor.v1_7_2.Processor
Description | The processor manufacturer |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MaxSpeedMHz
Member of Processor.v1_7_2.Processor
Description | The maximum clock speed of the processor |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Model
Member of Processor.v1_7_2.Processor
Description | The product model number of this device |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.AssetTag
Member of Processor.v1_7_2.Processor
Description | The processor asset tag. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Cache (array)
Member of Processor.v1_7_2.Processor
Cache
is an array containing elements of:
Cache[{item}].Associativity Member of Processor.v1_7_2.Processor
Description | The associativity of the cache. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
DirectMapped |
Direct Mapped |
2waySetAssociative |
2-way Set-Associative |
4waySetAssociative |
4-way Set-Associative |
FullyAssociative |
Fully Associative |
8waySetAssociative |
8-way Set-Associative |
16waySetAssociative |
16-way Set-Associative |
12waySetAssociative |
12-way Set-Associative |
24waySetAssociative |
24-way Set-Associative |
32waySetAssociative |
32-way Set-Associative |
48waySetAssociative |
48-way Set-Associative |
64waySetAssociative |
64-way Set-Associative |
20waySetAssociative |
20-way Set-Associative |
None |
Cache[{item}].CacheSpeedns Member of Processor.v1_7_2.Processor
Description | The cache speed (ns). |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Cache[{item}].CurrentSRAMType (array)
Member of Processor.v1_7_2.Processor
CurrentSRAMType
is an array containing elements of:
CurrentSRAMType[{item}] Member of Processor.v1_7_2.Processor
Description | The array of supported SRAM attributes currently used by the cache. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NonBurst |
Non-Burst |
Burst |
Burst |
PipelineBurst |
Pipeline Burst |
Synchronous |
Synchronous |
Asynchronous |
Asynchronous |
Cache[{item}].EccType Member of Processor.v1_7_2.Processor
Description | The cache memory ECC type. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
None |
None |
Parity |
Parity |
SingleBitECC |
Single-bit ECC |
MultiBitECC |
Multi-bit ECC |
Cache[{item}].InstalledSizeKB Member of Processor.v1_7_2.Processor
Description | The installed cache size (KB). |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Cache[{item}].Location Member of Processor.v1_7_2.Processor
Description | The cache location (internal or external). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Internal |
Internal |
External |
External |
Cache[{item}].MaximumSizeKB Member of Processor.v1_7_2.Processor
Description | The maximum cache size (KB). |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Cache[{item}].Policy Member of Processor.v1_7_2.Processor
Description | The caching policy. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
WriteThrough |
Write through |
WriteBack |
Write back |
Varies |
Varies with memory address |
Cache[{item}].Socketed Member of Processor.v1_7_2.Processor
Description | If true, the cache is a socketed component. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Cache[{item}].Status Member of Processor.v1_7_2.Processor See the Redfish standard schema and specification for information on common Status object.
Cache[{item}].SupportedSRAMType (array)
Member of Processor.v1_7_2.Processor
SupportedSRAMType
is an array containing elements of:
SupportedSRAMType[{item}] Member of Processor.v1_7_2.Processor
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NonBurst |
Non-Burst |
Burst |
Burst |
PipelineBurst |
Pipeline Burst |
Synchronous |
Synchronous |
Asynchronous |
Asynchronous |
Cache[{item}].SystemCacheType Member of Processor.v1_7_2.Processor
Description | The cache type (unified, instructions, or data). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Instruction |
Instruction |
Data |
Data |
Unified |
Unified |
Oem.Hpe.Characteristics (array)
Member of Processor.v1_7_2.Processor
Characteristics
is an array containing elements of:
Characteristics[{item}] Member of Processor.v1_7_2.Processor
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
64Bit |
64-bit Capable |
MultiCore |
Multi-Core |
HwThread |
Hardware Thread |
ExecuteProtection |
Execute Protection |
EnhancedVirtualization |
Enhanced Virtualization |
PowerPerfControl |
Power/Performance Control |
Oem.Hpe.ConfigStatus
Oem.Hpe.ConfigStatus.Populated Member of Processor.v1_7_2.Processor
Description | True if the processor socket is populated with a CPU. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ConfigStatus.State Member of Processor.v1_7_2.Processor
Description | The current state of the processor. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
CPU Enabled |
DisabledByUser |
CPU Disabled by User through BIOS Setup |
DisabledByBios |
CPU Disabled By BIOS (POST Error) |
Idle |
CPU is Idle, waiting to be enabled. |
Oem.Hpe.CoresEnabled
Member of Processor.v1_7_2.Processor
Description | The number of enabled cores in the processor. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ExternalClockMHz
Member of Processor.v1_7_2.Processor
Description | The processor external clock frequency (MHZ), for example, 1000 = 1 GHZ. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.MicrocodePatches (array)
Member of Processor.v1_7_2.Processor
MicrocodePatches
is an array containing elements of:
MicrocodePatches[{item}].CpuId Member of Processor.v1_7_2.Processor
Description | The microcode patch CPUID. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
MicrocodePatches[{item}].Date Member of Processor.v1_7_2.Processor
Description | The microcode patch date. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
MicrocodePatches[{item}].PatchId Member of Processor.v1_7_2.Processor
Description | The microcode patch ID. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PartNumber
Member of Processor.v1_7_2.Processor
Description | The processor part number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.RatedSpeedMHz
Member of Processor.v1_7_2.Processor
Description | The speed of the processor (in MHz) as of the last system boot, for example, 1000 = 1GHz. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SerialNumber
Member of Processor.v1_7_2.Processor
Description | The processor serial number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.VoltageVoltsX10
Member of Processor.v1_7_2.Processor
Description | The processor voltage multiplied by 10, for example, 3.3v = 33. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PartNumber
Member of Processor.v1_7_2.Processor
Description | The processor part number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorArchitecture
Member of Processor.v1_7_2.Processor
Description | The architecture of the processor |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
x86 |
x86 or x86-64 |
IA-64 |
Intel Itanium |
ARM |
ARM |
MIPS |
MIPS |
OEM |
OEM-defined |
ProcessorId
ProcessorId.EffectiveFamily Member of Processor.v1_7_2.Processor
Description | The effective Family for this processor |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorId.EffectiveModel Member of Processor.v1_7_2.Processor
Description | The effective Model for this processor |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorId.IdentificationRegisters Member of Processor.v1_7_2.Processor
Description | The contents of the Identification Registers (CPUID) for this processor |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorId.MicrocodeInfo Member of Processor.v1_7_2.Processor
Description | The Microcode Information for this processor |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorId.Step Member of Processor.v1_7_2.Processor
Description | The Step value for this processor |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorId.VendorId Member of Processor.v1_7_2.Processor
Description | The Vendor Identification for this processor |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorType
Member of Processor.v1_7_2.Processor
Description | The type of processor |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
CPU |
A Central Processing Unit |
GPU |
A Graphics Processing Unit |
FPGA |
A Field Programmable Gate Array |
DSP |
A Digital Signal Processor |
Accelerator |
An Accelerator |
OEM |
An OEM-defined Processing Unit |
SerialNumber
Member of Processor.v1_7_2.Processor
Description | The processor serial number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Socket
Member of Processor.v1_7_2.Processor
Description | The socket or location of the processor |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of Processor.v1_7_2.Processor See the Redfish standard schema and specification for information on common Status object.
TotalCores
Member of Processor.v1_7_2.Processor
Description | The total number of cores contained in this processor |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
TotalThreads
Member of Processor.v1_7_2.Processor
Description | The total number of execution threads supported by this processor |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorCollection.ProcessorCollection
@odata.type: "#ProcessorCollection.ProcessorCollection"
A Collection of Processor resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/processors |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Processor |
Members (array)
Member of ProcessorCollection.ProcessorCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of ProcessorCollection.ProcessorCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of ProcessorCollection.ProcessorCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Role.v1_2_1.Role
@odata.type: "#Role.v1_2_1.Role"
This resource defines a user role to be used in conjunction with a Manager Account.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/roles/{item} |
GET PATCH |
AssignedPrivileges (array)
Member of Role.v1_2_1.Role
AssignedPrivileges
is an array containing elements of:
AssignedPrivileges[{item}] Member of Role.v1_2_1.Role
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Login |
Able to log into the service and read resources. |
ConfigureManager |
Able to configure Manager resources. |
ConfigureUsers |
Able to configure Users and their Accounts. |
ConfigureSelf |
Able to change the password for the current user Account. |
ConfigureComponents |
Able to configure components managed by this service. |
IsPredefined
Member of Role.v1_2_1.Role
Description | This property is used to indicate if the Role is one of the Redfish Predefined Roles vs a Custom role. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.GroupDn
Member of Role.v1_2_1.Role
Description | The complete or shortened distinguished name of the directory group. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.GroupSid
Member of Role.v1_2_1.Role
Description | The security identifier of the directory group (for kerberos authentication and Active Directory integration only). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
OemPrivileges (array)
Member of Role.v1_2_1.Role
OemPrivileges
is an array containing elements of:
OemPrivileges[{item}] Member of Role.v1_2_1.Role
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
RemoteConsolePriv |
Able to remotely access the host system Remote Console, including video, keyboard, and mouse control. |
VirtualMediaPriv |
Able to use the Virtual Media feature on the host system. |
VirtualPowerAndResetPriv |
Able to power-cycle or reset the host system. These activities interrupt system availability. A user with this privilege can diagnose the system by using the Generate NMI to System button. |
HostBIOSConfigPriv |
Able to configure Host BIOS Settings. |
HostNICConfigPriv |
Able to configure Host NIC Settings. |
HostStorageConfigPriv |
Able to configure Host Storage Settings. |
SystemRecoveryConfigPriv |
Able to manage the critical recovery firmware images on the Manager’s Repository. |
RoleId
Member of Role.v1_2_1.Role
Description | This property contains the name of the Role. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
RoleCollection.RoleCollection
@odata.type: "#RoleCollection.RoleCollection"
A Collection of Role resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/roles |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Role |
Members (array)
Member of RoleCollection.RoleCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of RoleCollection.RoleCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of RoleCollection.RoleCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
SecureBoot.v1_1_0.SecureBoot
@odata.type: "#SecureBoot.v1_1_0.SecureBoot"
This resource contains UEFI Secure Boot information. It represents properties for managing the UEFI Secure Boot functionality of a system.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/secureboot |
GET POST PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
securebootdatabases |
Collection of SecureBootDatabase |
SecureBootCurrentBoot
Member of SecureBoot.v1_1_0.SecureBoot
Description | Secure Boot state during the current boot cycle. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Secure Boot is currently enabled. |
Disabled |
Secure Boot is currently disabled. |
SecureBootDatabases
A link to the collection of UEFI Secure Boot databases.
SecureBootDatabases is a link ("@odata.id": URI
) to another resource.
SecureBootEnable
Member of SecureBoot.v1_1_0.SecureBoot
Description | Enable or disable UEFI Secure Boot (takes effect on next boot). |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
SecureBootMode
Member of SecureBoot.v1_1_0.SecureBoot
Description | Current Secure Boot Mode. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
SetupMode |
Secure Boot is currently in Setup Mode. |
UserMode |
Secure Boot is currently in User Mode. |
AuditMode |
Secure Boot is currently in Audit Mode. |
DeployedMode |
Secure Boot is currently in Deployed Mode. |
Actions
SecureBoot.ResetKeys Member of SecureBoot.v1_1_0.SecureBoot Action to perform reset of the Secure Boot Keys.
Parameters:
ResetKeysType (string)
This parameter specifies what type of reset action to perform.
Value | Description |
---|---|
ResetAllKeysToDefault | Reset to default Secure Boot keys on next boot. |
DeletePK | Delete Secure Boot platform keys on next boot. |
DeleteAllKeys | Delete all Secure Boot keys on next boot. |
SecureBootDatabase.v1_0_0.SecureBootDatabase
@odata.type: "#SecureBootDatabase.v1_0_0.SecureBootDatabase"
The SecureBootDatabase schema describes a UEFI Secure Boot database used to store certificates or hashes.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/PK |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/db |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbdefault |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kek |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kekdefault |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/pkdefault |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Certificates |
Collection of Certificate |
Signatures |
Collection of Signature |
Certificates
A link to the collection of certificates contained in this UEFI Secure Boot database.
Certificates is a link ("@odata.id": URI
) to another resource.
DatabaseId
Member of SecureBootDatabase.v1_0_0.SecureBootDatabase
Description | This property contains the name of the UEFI Secure Boot database. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Signatures
A link to the collection of signatures contained in this UEFI Secure Boot database.
Signatures is a link ("@odata.id": URI
) to another resource.
Actions
SecureBootDatabase.ResetKeys Member of SecureBootDatabase.v1_0_0.SecureBootDatabase Action to perform reset of the Secure Boot Database Keys.
Parameters:
ResetKeysType (string)
This parameter specifies what type of reset action to perform.
Value | Description |
---|---|
ResetAllKeysToDefault | Reset to default Secure Boot Database keys on next boot. |
DeleteAllKeys | Delete all Secure Boot Database keys on next boot. |
SecureBootDatabaseCollection.SecureBootDatabaseCollection
@odata.type: "#SecureBootDatabaseCollection.SecureBootDatabaseCollection"
The collection of SecureBootDatabase resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/secureboot/securebootdatabases |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
SecureBootDatabase |
Members (array)
Member of SecureBootDatabaseCollection.SecureBootDatabaseCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of SecureBootDatabaseCollection.SecureBootDatabaseCollection
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Format | uri-reference |
Members@odata.count
Member of SecureBootDatabaseCollection.SecureBootDatabaseCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.10 |
SerialInterface.v1_1_7.SerialInterface
@odata.type: "#SerialInterface.v1_1_7.SerialInterface"
This is the schema definition for the Serial Interface.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/serialinterfaces/{item} |
GET PATCH |
BitRate
Member of SerialInterface.v1_1_7.SerialInterface
Description | The receive and transmit rate of data flow, typically in bits per second (bit/s), over the serial connection. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
9600 |
A bit rate of 9600 bit/s. |
19200 |
A bit rate of 19200 bit/s. |
38400 |
A bit rate of 38400 bit/s. |
57600 |
A bit rate of 57600 bit/s. |
115200 |
A bit rate of 115200 bit/s. |
InterfaceEnabled
Member of SerialInterface.v1_1_7.SerialInterface
Description | An indication of whether this interface is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
SerialInterfaceCollection.SerialInterfaceCollection
@odata.type: "#SerialInterfaceCollection.SerialInterfaceCollection"
A Collection of SerialInterface resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/serialinterfaces |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
SerialInterface |
Members (array)
Member of SerialInterfaceCollection.SerialInterfaceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of SerialInterfaceCollection.SerialInterfaceCollection
Type | string |
Read Only | True |
Added | iLO6 1.40 |
Format | uri-reference |
Members@odata.count
Member of SerialInterfaceCollection.SerialInterfaceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.40 |
ServiceRoot.v1_13_0.ServiceRoot
@odata.type: "#ServiceRoot.v1_13_0.ServiceRoot"
The ServiceRoot resource describes the Redfish API service root.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/ |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Registries |
Collection of MessageRegistryFile |
Managers |
Collection of Manager |
AccountService |
AccountService |
JsonSchemas |
Collection of JsonSchemaFile |
UpdateService |
UpdateService |
ComponentIntegrity |
Collection of ComponentIntegrity |
SessionService |
SessionService |
EventService |
EventService |
Chassis |
Collection of Chassis |
Oem/Hpe/Links/ResourceDirectory |
HpeiLOResourceDirectory |
Systems |
Collection of ComputerSystem |
Links/Sessions |
Collection of Session |
AccountService
The URI to this account service resource.
AccountService is a link ("@odata.id": URI
) to another resource.
CertificateService
The URI to the certificate service resource.
CertificateService is a link ("@odata.id": URI
) to another resource.
Chassis
The URI to this chassis resource.
Chassis is a link ("@odata.id": URI
) to another resource.
ComponentIntegrity
The URI to this collection resource.
ComponentIntegrity is a link ("@odata.id": URI
) to another resource.
EventService
The URI to the event service resource.
EventService is a link ("@odata.id": URI
) to another resource.
JsonSchemas
The URI to this registries resource.
JsonSchemas is a link ("@odata.id": URI
) to another resource.
Managers
The URI to this managers resource.
Managers is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.CACLoginUri
Member of ServiceRoot.v1_13_0.ServiceRoot
Description | URI for the CAC based authentication. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Format | uri-reference |
Oem.Hpe.DebugCode
Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Specifies whether the iLO has debug firmware flashed. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DevSystem
Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Specifies whether the test key is enabled. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Manager (array)
Member of ServiceRoot.v1_13_0.ServiceRoot
Manager
is an array containing elements of:
Manager[{item}].Blade Manager[{item}].Blade.BayNumber Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Specifies the location of the blade in the enclosure. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Manager[{item}].Blade.EnclosureName Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Specifies the name of the enclosure in which the blade is present. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Manager[{item}].Blade.RackName Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Specifies the name of the rack in which the enclosure is present. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Manager[{item}].DefaultLanguage Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Default language used for the Web interface. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Manager[{item}].ExternalManager Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Reports the current external manager of the system. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Manager[{item}].FQDN Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Fully qualified domain name of the management processor. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Manager[{item}].HostName Member of ServiceRoot.v1_13_0.ServiceRoot
Description | The name of management processor. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Manager[{item}].IPManager
Manager[{item}].Languages (array)
Member of ServiceRoot.v1_13_0.ServiceRoot
Languages
is an array containing elements of:
Languages[{item}].Language Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Specifies one of the languages supported by the management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Languages[{item}].TranslationName Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Specifies one of the languages supported by the management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Languages[{item}].Version Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Specifies the version of the management processor in the respective language. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Manager[{item}].ManagerFirmwareVersion Member of ServiceRoot.v1_13_0.ServiceRoot
Description | The major and minor management processor version numbers. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Manager[{item}].ManagerFirmwareVersionPass Member of ServiceRoot.v1_13_0.ServiceRoot
Description | The build or pass number of the management processor version. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Manager[{item}].ManagerType Member of ServiceRoot.v1_13_0.ServiceRoot
Description | The type of the service manager. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Manager[{item}].SelfTestErrors (array)
Member of ServiceRoot.v1_13_0.ServiceRoot
SelfTestErrors
is an array containing elements of:
SelfTestErrors[{item}].SelfTestName Member of ServiceRoot.v1_13_0.ServiceRoot
Description | iLO Self Test Name. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Manager[{item}].Status Member of ServiceRoot.v1_13_0.ServiceRoot See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.Moniker
Oem.Hpe.Moniker.ADVLIC Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Optional Licensed functionality tier name. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.BMC Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Generic abbreviation for the management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.BSYS Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Product category name. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.CLASS Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Management processor product category. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.FEDGRP Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Default federation group name. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.IPROV Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Product name for provisioning and deployment suite. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.PRODABR Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Abbreviated product name. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.PRODFAM Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Full product family. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.PRODGEN Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Abbreviated product name and generation. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.PRODNAM Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Full product name. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.PRODTAG Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Branded, abbreviated product name. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.STDLIC Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Base licensed functionality tier name. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.SUMABR Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Acronym for update deployment suite. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.SUMGR Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Product name for update deployment suite. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.SYSFAM Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Host system product family. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.SYSMGMT Member of ServiceRoot.v1_13_0.ServiceRoot
Description | System Management Experience. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.VENDABR Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Abbreviated vendor name (like stock ticker). |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.VENDNAM Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Full vendor name. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.VNIC Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Virtual USB network interface to BMC name. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWW Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Top level public internet vendor URI. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWWAHSV Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Public internet vendor URI for Active Health viewer. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWWBMC Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Public internet vendor URI for the management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWWDOC Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Public internet vendor URI for the management processor documentation / manuals. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWWERS Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Public internet vendor URI for Embedded Remote Support. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWWGLIS Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Public internet vendor URI for management processor licensing infrastructure. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWWINFOSIGHT Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Public internet resource for active health. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWWIOL Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Public internet vendor URI for Online Insight service. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWWLIC Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Public internet vendor URI for the management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWWLML Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Public internet vendor URI for Learn More Links. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWWPASS Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Public internet vendor URI for accessing support account. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWWPRV Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Public internet vendor URI for privacy policy statement. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWWQSPEC Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Public internet vendor URI for Quick Specs. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWWRESTDOC Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Public internet vendor URI for REST API documentation. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWWSUP Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Public internet vendor URI for management processor and product support. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Moniker.WWWSWLIC Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Public internet vendor URI for vendor software licensing. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PreProd
Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Specifies whether the system identifies as pre-production. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Sessions
Oem.Hpe.Sessions.CertCommonName Member of ServiceRoot.v1_13_0.ServiceRoot
Description | The name of the management processor as it appears in the digital certificate when a secure web GUI session is established to the management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Sessions.CertificateLoginEnabled Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Specifies whether Certificate login is enabled. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Sessions.KerberosEnabled Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Specifies whether Kerberos login is enabled. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Sessions.LDAPAuthLicenced Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Specifies whether a valid license is installed for LDAP use. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Sessions.LDAPEnabled Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Specifies whether LDAP login is enabled. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Sessions.LocalLoginEnabled Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Specifies whether local users can log in. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Sessions.LoginFailureDelay Member of ServiceRoot.v1_13_0.ServiceRoot
Description | The delay (seconds) when a management processor login attempt has failed. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Sessions.LoginHint Oem.Hpe.Sessions.LoginHint.Hint Member of ServiceRoot.v1_13_0.ServiceRoot
Description | The information on how to log in to the management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Sessions.LoginHint.HintPOSTData Oem.Hpe.Sessions.LoginHint.HintPOSTData.Password Member of ServiceRoot.v1_13_0.ServiceRoot
Description | The password for logging in to the management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Sessions.LoginHint.HintPOSTData.UserName Member of ServiceRoot.v1_13_0.ServiceRoot
Description | The user name for logging in to the management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Sessions.SecurityMessage Member of ServiceRoot.v1_13_0.ServiceRoot
Description | The login security banner message that is displayed on the management processor Login page. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Sessions.SecurityOverride Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Specifies whether the security override switch is enabled. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Sessions.ServerName Member of ServiceRoot.v1_13_0.ServiceRoot
Description | The name of the server that this management processor is managing. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.System (array)
Member of ServiceRoot.v1_13_0.ServiceRoot
System
is an array containing elements of:
System[{item}].Status Member of ServiceRoot.v1_13_0.ServiceRoot See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.Time
Member of ServiceRoot.v1_13_0.ServiceRoot
Description | The current Redfish service time. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Product
Member of ServiceRoot.v1_13_0.ServiceRoot
Description | The product associated with this Redfish service. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProtocolFeaturesSupported
ProtocolFeaturesSupported.ExpandQuery ProtocolFeaturesSupported.ExpandQuery.ExpandAll Member of ServiceRoot.v1_13_0.ServiceRoot
Description | This indicates whether the expand support of asterisk (expand all entries) is supported. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
ProtocolFeaturesSupported.ExpandQuery.Levels Member of ServiceRoot.v1_13_0.ServiceRoot
Description | This indicates whether the expand support of the $levels qualifier is supported by the service. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
ProtocolFeaturesSupported.ExpandQuery.MaxLevels Member of ServiceRoot.v1_13_0.ServiceRoot
Description | This indicates the maximum number value of the $levels qualifier in expand operations. |
Type | number |
Read Only | True |
Added | iLO6 1.05 |
ProtocolFeaturesSupported.ExpandQuery.NoLinks Member of ServiceRoot.v1_13_0.ServiceRoot
Description | This indicates whether the expand support of period (expand only entries not in the Links section) is supported. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
ProtocolFeaturesSupported.FilterQuery Member of ServiceRoot.v1_13_0.ServiceRoot
Description | This indicates whether the filter query parameter is supported. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
ProtocolFeaturesSupported.OnlyMemberQuery Member of ServiceRoot.v1_13_0.ServiceRoot
Description | This indicates whether Management Processor supports the only query option. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
ProtocolFeaturesSupported.SelectQuery Member of ServiceRoot.v1_13_0.ServiceRoot
Description | This indicates whether the select query parameter is supported. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
RedfishVersion
Member of ServiceRoot.v1_13_0.ServiceRoot
Description | The version of the Redfish service |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Registries
The URI to this registries resource.
Registries is a link ("@odata.id": URI
) to another resource.
SessionService
The URI to this sessions service resource.
SessionService is a link ("@odata.id": URI
) to another resource.
Systems
The URI to this systems resource.
Systems is a link ("@odata.id": URI
) to another resource.
Tasks
The URI to this tasks service resource.
Tasks is a link ("@odata.id": URI
) to another resource.
TelemetryService
The URI to the TelemetryService resource.
TelemetryService is a link ("@odata.id": URI
) to another resource.
UUID
Member of ServiceRoot.v1_13_0.ServiceRoot
Description | Unique identifier for a service instance. This value should be an exact match of the UUID value returned in a 200OK from an SSDP M-SEARCH request during discovery. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
UpdateService
The URI to this UpdateService resource.
UpdateService is a link ("@odata.id": URI
) to another resource.
Vendor
Member of ServiceRoot.v1_13_0.ServiceRoot
Description | The vendor of the product associated with this Redfish service. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Session.v1_0_0.Session
@odata.type: "#Session.v1_0_0.Session"
The Session resource describes a single connection (session) between a client and a Redfish service instance.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/sessionservice/sessions/{item} |
GET DELETE |
Oem.Hpe.AccessTime
Member of Session.v1_0_0.Session
Description | User session last-access time |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Oem.Hpe.LoginTime
Member of Session.v1_0_0.Session
Description | User session login time |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Oem.Hpe.MySession
Member of Session.v1_0_0.Session
Description | Indicates whether this is a session I own. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges
Oem.Hpe.Privileges.HostBIOSConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to configure Host Bios Settings. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.HostNICConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to configure Host NIC Settings. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.HostStorageConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to configure Host Storage Settings. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.LoginPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to log in to the management processor. All local accounts have the login privilege. This privilege is added automatically if it is not specified. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.RemoteConsolePriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to remotely access the host system Remote Console, including video, keyboard, and mouse control. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.SystemRecoveryConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to manage the critical recovery firmware images on the iLO Repository. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.UserConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to add, edit, and delete local management processor user accounts. A user with this privilege can change privileges for all users. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.VirtualMediaPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to use the Virtual Media feature on the host system. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.VirtualPowerAndResetPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to power-cycle or reset the host system. These activities interrupt system availability. A user with this privilege can diagnose the system by using the Generate NMI to System button. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.iLOConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to configure most management processor settings, including security settings, and to remotely update the management processor firmware. This privilege does not enable local user account administration. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.UserAccount
Member of Session.v1_0_0.Session
Description | Login details of the user |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.UserDistinguishedName
Member of Session.v1_0_0.Session
Description | LDAP user is identified by its distinguished name (DN). |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.UserExpires
Member of Session.v1_0_0.Session
Description | User session expire time |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Oem.Hpe.UserIP
Member of Session.v1_0_0.Session
Description | IP address of the user |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.UserTag
Member of Session.v1_0_0.Session
Description | Session source |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Web UI |
RBSU |
Remote Console |
SSH |
IPMI/RMCP |
SM-CLP |
RIBCL |
RESTHost |
RIBCLHost |
WSMgmt |
Telnet |
Federation |
USBFrontPort |
REST |
Unknown |
Oem.Hpe.UserType
Member of Session.v1_0_0.Session
Description | User type |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Local |
Directory |
Single Sign On |
Kerberos |
Trusted Key |
Security Override |
System |
Federation |
UserName
Member of Session.v1_0_0.Session
Description | Name to use to log in to the management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
SessionCollection.SessionCollection
@odata.type: "#SessionCollection.SessionCollection"
A Collection of Session resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/sessionservice/sessions |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Oem/Hpe/Links/MySession |
Session |
Members[] |
Session |
Members (array)
Member of SessionCollection.SessionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of SessionCollection.SessionCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of SessionCollection.SessionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
SessionService.v1_0_0.SessionService
@odata.type: "#SessionService.v1_0_0.SessionService"
The SessionService resource describes the BMC Redfish Session Service. It represents the properties for the service itself and has links to the actual list of sessions.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/sessionservice |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Sessions |
Collection of Session |
ServiceEnabled
Member of SessionService.v1_0_0.SessionService
Description | This indicates whether this service is enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
SessionTimeout
Member of SessionService.v1_0_0.SessionService
Description | This is the number of seconds of inactivity that a session may have before the session service closes the session due to inactivity. Here the value 0 means no timeout or infinite timeout. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Sessions
This property references a Collection resource of Sessions.
Sessions is a link ("@odata.id": URI
) to another resource.
Status
Member of SessionService.v1_0_0.SessionService See the Redfish standard schema and specification for information on common Status object.
Signature.v1_0_2.Signature
@odata.type: "#Signature.v1_0_2.Signature"
The Signature schema describes a signature or a hash.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/secureboot/securebootdatabases/db/signatures/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbdefault/signatures/{item} |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr/signatures/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault/signatures/{item} |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt/signatures/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault/signatures/{item} |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx/signatures/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault/signatures/{item} |
GET |
SignatureString
Member of Signature.v1_0_2.Signature
Description | The string for the signature. |
Type | string |
Read Only | False |
Added | iLO6 1.10 |
SignatureType
Member of Signature.v1_0_2.Signature
Description | The format of the signature. |
Type | string |
Read Only | False |
Added | iLO6 1.10 |
SignatureTypeRegistry
Member of Signature.v1_0_2.Signature
Type | string |
Read Only | False |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
UEFI |
A signature defined in the UEFI Specification. |
UefiSignatureOwner
Member of Signature.v1_0_2.Signature
Description | The UEFI signature owner for this signature. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
SignatureCollection.SignatureCollection
@odata.type: "#SignatureCollection.SignatureCollection"
The collection of Signature resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/secureBoot/securebootdatabases/dbdefault/signatures |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/db/signatures |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr/signatures |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault/signatures |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt/signatures |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault/signatures |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx/signatures |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault/signatures |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Signature |
Members (array)
Member of SignatureCollection.SignatureCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of SignatureCollection.SignatureCollection
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Format | uri-reference |
Members@odata.count
Member of SignatureCollection.SignatureCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.10 |
SoftwareInventory.v1_2_0.SoftwareInventory
@odata.type: "#SoftwareInventory.v1_2_0.SoftwareInventory"
The SoftwareInventory resource describes the inventory of software or firmware components.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/firmwareinventory/{item} |
GET |
/redfish/v1/updateservice/softwareinventory/{item} |
GET |
Manufacturer
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | The manufacturer or producer of this software. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DeviceClass
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | DeviceType GUID rendered by iLO for certain items iLO knows how to flash, and omitted for all other items. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DeviceContext
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | Friendly text string - same as ‘Location’ in fw inventory - omitted if not available. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DeviceInstance
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | UEFI Device Path if a PCI Device - omitted otherwise. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Targets (array)
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Targets
is an array containing elements of:
Targets[{item}] Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | A GUID indicating iLO’s knowledge of a possible correlation GUIDs vs. components. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Version
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | NVIDIA CEC Firmware version |
Type | string or null |
Read Only | True |
Added | iLO6 1.30 |
RelatedItem (array)
Member of SoftwareInventory.v1_2_0.SoftwareInventory
RelatedItem
is an array containing elements of:
RelatedItem[{item}].@odata.id Member of SoftwareInventory.v1_2_0.SoftwareInventory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
RelatedItem@odata.count
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | The number of items in a collection. |
Type | number |
Read Only | True |
Added | iLO6 1.05 |
SoftwareId
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | The implementation-specific label that identifies this software. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of SoftwareInventory.v1_2_0.SoftwareInventory See the Redfish standard schema and specification for information on common Status object.
Updateable
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | This is true if the item is updatable. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Version
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | same as ‘VersionString’ in existing FwSwVersionInventory |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SoftwareInventoryCollection.SoftwareInventoryCollection
@odata.type: "#SoftwareInventoryCollection.SoftwareInventoryCollection"
A Collection of SoftwareInventory resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/firmwareinventory |
GET |
/redfish/v1/updateservice/softwareinventory |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
SoftwareInventory |
Members (array)
Member of SoftwareInventoryCollection.SoftwareInventoryCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of SoftwareInventoryCollection.SoftwareInventoryCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of SoftwareInventoryCollection.SoftwareInventoryCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Storage.v1_12_0.Storage
@odata.type: "#Storage.v1_12_0.Storage"
Storage defines a storage subsystem and its respective properties. A storage subsystem represents a set of storage controllers (physical or virtual) and the resources such as volumes that can be accessed from that subsystem.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/storage/{item} |
GET POST PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Volumes |
Collection of Volume |
StorageControllers |
Collection of StorageController |
Links/Enclosures[] |
Chassis |
Ports |
Collection of Port |
Drives[] |
Drive |
Controllers
The set of controllers instantiated by this storage subsystem.
Controllers is a link ("@odata.id": URI
) to another resource.
Drives (array)
Member of Storage.v1_12_0.Storage
Drives
is an array containing elements of:
Drives[{item}].@odata.id Member of Storage.v1_12_0.Storage
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Drives@odata.count
Member of Storage.v1_12_0.Storage
Description | The number of items in a collection. |
Type | number |
Read Only | True |
Added | iLO6 1.20 |
Status
Member of Storage.v1_12_0.Storage See the Redfish standard schema and specification for information on common Status object.
StorageControllers (array)
Member of Storage.v1_12_0.Storage
StorageControllers
is an array containing elements of:
StorageControllers[{item}].@odata.id Member of Storage.v1_12_0.Storage
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
StorageControllers[{item}].CacheSummary StorageControllers[{item}].CacheSummary.PersistentCacheSizeMiB Member of Storage.v1_12_0.Storage
Description | The portion of the cache memory that is persistent, measured in MiB. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
StorageControllers[{item}].CacheSummary.Status Member of Storage.v1_12_0.Storage See the Redfish standard schema and specification for information on common Status object.
StorageControllers[{item}].CacheSummary.TotalCacheSizeMiB Member of Storage.v1_12_0.Storage
Description | The total configured cache memory, measured in MiB. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
StorageControllers[{item}].ControllerRates StorageControllers[{item}].ControllerRates.ConsistencyCheckRatePercent Member of Storage.v1_12_0.Storage
Description | The percentage of controller resources used for performing a data consistency check on volumes. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
StorageControllers[{item}].ControllerRates.RebuildRatePercent Member of Storage.v1_12_0.Storage
Description | The percentage of controller resources used for rebuilding/repairing volumes. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
StorageControllers[{item}].ControllerRates.TransformationRatePercent Member of Storage.v1_12_0.Storage
Description | The percentage of controller resources used for transforming volumes from one configuration to another. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
StorageControllers[{item}].FirmwareVersion Member of Storage.v1_12_0.Storage
Description | The firmware version of this storage controller. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
StorageControllers[{item}].Identifiers (array)
Member of Storage.v1_12_0.Storage
Identifiers
is an array containing elements of:
Identifiers[{item}].DurableName Member of Storage.v1_12_0.Storage
Description | The world-wide, persistent name of the resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Identifiers[{item}].DurableNameFormat Member of Storage.v1_12_0.Storage
Description | The format of the durable name property. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NAA |
The Name Address Authority (NAA) format. |
iQN |
The iSCSI Qualified Name (iQN). |
FC_WWN |
The Fibre Channel (FC) World Wide Name (WWN). |
UUID |
The Universally Unique Identifier (UUID). |
EUI |
The IEEE-defined 64-bit Extended Unique Identifier (EUI). |
NQN |
The NVMe Qualified Name (NQN). |
NGUID |
The Namespace Globally Unique Identifier (NGUID). |
StorageControllers[{item}].Location StorageControllers[{item}].Location.PartLocation StorageControllers[{item}].Location.PartLocation.LocationOrdinalValue Member of Storage.v1_12_0.Storage
Description | The number that represents the location of the part. If LocationType is slot and this unit is in slot 2, the LocationOrdinalValue is 2. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
StorageControllers[{item}].Location.PartLocation.LocationType Member of Storage.v1_12_0.Storage
Description | The location types for PartLocation. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Slot |
The slot as the type of location. |
Bay |
The bay as the type of location. |
Connector |
The connector as the type of location. |
Socket |
The socket as the type of location. |
Embedded |
Embedded within a part. |
StorageControllers[{item}].Location.PartLocation.Orientation Member of Storage.v1_12_0.Storage
Description | The orientation for the ordering of the part location ordinal value. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
FrontToBack |
The ordering for LocationOrdinalValue is front to back. |
BackToFront |
The ordering for the LocationOrdinalValue is back to front. |
TopToBottom |
The ordering for the LocationOrdinalValue is top to bottom. |
BottomToTop |
The ordering for LocationOrdinalValue is bottom to top. |
LeftToRight |
The ordering for the LocationOrdinalValue is left to right. |
RightToLeft |
The ordering for the LocationOrdinalValue is right to left. |
StorageControllers[{item}].Location.PartLocation.Reference Member of Storage.v1_12_0.Storage
Description | The reference area for the location of the part. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Top |
The part is in the top of the unit. |
Bottom |
The part is in the bottom of the unit. |
Front |
The part is in the front of the unit. |
Rear |
The part is in the rear of the unit. |
Left |
The part is on the left side of of the unit. |
Right |
The part is on the right side of the unit. |
Middle |
The part is in the middle of the unit. |
StorageControllers[{item}].Location.PartLocation.ServiceLabel Member of Storage.v1_12_0.Storage
Description | The label of the part location, such as a silk-screened name or a printed label. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
StorageControllers[{item}].Location.Placement StorageControllers[{item}].Location.Placement.AdditionalInfo Member of Storage.v1_12_0.Storage
Description | Area designation or other additional info. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
StorageControllers[{item}].Location.Placement.Rack Member of Storage.v1_12_0.Storage
Description | The name of a rack location within a row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
StorageControllers[{item}].Location.Placement.RackOffset Member of Storage.v1_12_0.Storage
Description | The vertical location of the item, in terms of RackOffsetUnits. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
StorageControllers[{item}].Location.Placement.RackOffsetUnits Member of Storage.v1_12_0.Storage
Description | The type of rack unit in use. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OpenU |
A rack unit that is equal to 48 mm (1.89 in). |
EIA_310 |
A rack unit that is equal to 1.75 in (44.45 mm). |
StorageControllers[{item}].Location.Placement.Row Member of Storage.v1_12_0.Storage
Description | The name of the row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
StorageControllers[{item}].Manufacturer Member of Storage.v1_12_0.Storage
Description | Controller Manufacturer name. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
StorageControllers[{item}].MemberId Member of Storage.v1_12_0.Storage
Description | This is the identifier for the member within the collection. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
StorageControllers[{item}].Model Member of Storage.v1_12_0.Storage
Description | Controller model name. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
StorageControllers[{item}].PCIeInterface StorageControllers[{item}].PCIeInterface.LanesInUse Member of Storage.v1_12_0.Storage
Description | This is the number of PCIe lanes in use by this device. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
StorageControllers[{item}].PCIeInterface.MaxLanes Member of Storage.v1_12_0.Storage
Description | This is the number of PCIe lanes supported by this device. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
StorageControllers[{item}].PCIeInterface.MaxPCIeType Member of Storage.v1_12_0.Storage
Description | The highest version of the PCIe specification supported by this device. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Gen1 |
A PCIe v1.0 slot. |
Gen2 |
A PCIe v2.0 slot. |
Gen3 |
A PCIe v3.0 slot. |
Gen4 |
A PCIe v4.0 slot. |
Gen5 |
A PCIe v5.0 slot. |
StorageControllers[{item}].PCIeInterface.PCIeType Member of Storage.v1_12_0.Storage
Description | The version of the PCIe specification in use by this device. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Gen1 |
A PCIe v1.0 slot. |
Gen2 |
A PCIe v2.0 slot. |
Gen3 |
A PCIe v3.0 slot. |
Gen4 |
A PCIe v4.0 slot. |
Gen5 |
A PCIe v5.0 slot. |
StorageControllers[{item}].PartNumber Member of Storage.v1_12_0.Storage
Description | The part number for this storage controller. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
StorageControllers[{item}].SKU Member of Storage.v1_12_0.Storage
Description | The SKU for this storage controller. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
StorageControllers[{item}].SerialNumber Member of Storage.v1_12_0.Storage
Description | Controller serial number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
StorageControllers[{item}].SpeedGbps Member of Storage.v1_12_0.Storage
Description | The maximum speed of the storage controller’s device interface. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
StorageControllers[{item}].Status Member of Storage.v1_12_0.Storage See the Redfish standard schema and specification for information on common Status object.
StorageControllers[{item}].SupportedControllerProtocols (array)
Member of Storage.v1_12_0.Storage
SupportedControllerProtocols
is an array containing elements of:
SupportedControllerProtocols[{item}] Member of Storage.v1_12_0.Storage
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
PCIe |
StorageControllers[{item}].SupportedDeviceProtocols (array)
Member of Storage.v1_12_0.Storage
SupportedDeviceProtocols
is an array containing elements of:
SupportedDeviceProtocols[{item}] Member of Storage.v1_12_0.Storage
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NVMe |
Non-Volatile Memory Express (NVMe). |
SAS |
Serial Attached SCSI. |
SATA |
Serial AT Attachment. |
USB |
Universal Serial Bus (USB). |
StorageControllers[{item}].SupportedRAIDTypes (array)
Member of Storage.v1_12_0.Storage
SupportedRAIDTypes
is an array containing elements of:
SupportedRAIDTypes[{item}] Member of Storage.v1_12_0.Storage
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
RAID0 |
A placement policy where consecutive logical blocks of data are uniformly distributed across a set of independent storage devices without offering any form of redundancy. |
RAID1 |
A placement policy where each logical block of data is stored on more than one independent storage device. |
RAID3 |
A placement policy using parity-based protection where logical bytes of data are uniformly distributed across a set of independent storage devices and where the parity is stored on a dedicated independent storage device. |
RAID4 |
A placement policy using parity-based protection where logical blocks of data are uniformly distributed across a set of independent storage devices and where the parity is stored on a dedicated independent storage device. |
RAID5 |
A placement policy using parity-based protection for storing stripes of ‘n’ logical blocks of data and one logical block of parity across a set of ‘n+1’ independent storage devices where the parity and data blocks are interleaved across the storage devices. |
RAID6 |
A placement policy using parity-based protection for storing stripes of ‘n’ logical blocks of data and two logical blocks of independent parity across a set of ‘n+2’ independent storage devices where the parity and data blocks are interleaved across the storage devices. |
RAID10 |
A placement policy that creates a striped device (RAID 0) over a set of mirrored devices (RAID 1). |
RAID01 |
A data placement policy that creates a mirrored device (RAID 1) over a set of striped devices (RAID 0). |
RAID6TP |
A placement policy that uses parity-based protection for storing stripes of ‘n’ logical blocks of data and three logical blocks of independent parity across a set of ‘n+3’ independent storage devices where the parity and data blocks are interleaved across the storage devices. |
RAID1E |
A placement policy that uses a form of mirroring implemented over a set of independent storage devices where logical blocks are duplicated on a pair of independent storage devices so that data is uniformly distributed across the storage devices. |
RAID50 |
A placement policy that uses a RAID 0 stripe set over two or more RAID 5 sets of independent storage devices. |
RAID60 |
A placement policy that uses a RAID 0 stripe set over two or more RAID 6 sets of independent storage devices. |
RAID00 |
A placement policy that creates a RAID 0 stripe set over two or more RAID 0 sets. |
RAID10E |
A placement policy that uses a RAID 0 stripe set over two or more RAID 10 sets. |
RAID1Triple |
A placement policy where each logical block of data is mirrored three times across a set of three independent storage devices. |
RAID10Triple |
A placement policy that uses a striped device (RAID 0) over a set of triple mirrored devices (RAID 1Triple). |
None |
A placement policy with no redundancy at the device level. |
Volumes
A reference to the Volumes associated with this storage system.
Volumes is a link ("@odata.id": URI
) to another resource.
Actions
Storage.ResetToDefaults Member of Storage.v1_12_0.Storage This action resets the system.
Parameters:
ResetType (string)
Value | Description |
---|---|
ResetAll | Reset all settings to factory defaults and remove all volumes. |
PreserveVolumes | Reset all settings to factory defaults but preserve the configured volumes on the controllers. |
target (string)
Link to invoke action
title (string)
Friendly action name
StorageCollection.StorageCollection
@odata.type: "#StorageCollection.StorageCollection"
A Collection of Storage resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/storage |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Storage |
Members (array)
Member of StorageCollection.StorageCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of StorageCollection.StorageCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of StorageCollection.StorageCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
StorageController.v1_0_0.StorageController
@odata.type: "#StorageController.v1_0_0.StorageController"
The StorageController schema describes a storage controller and its properties. A storage controller represents a physical or virtual storage device that produces volumes.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/storage/{item}/controllers/{item} |
GET |
AssetTag
Member of StorageController.v1_0_0.StorageController
Description | The user-assigned asset tag for this storage controller. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
CacheSummary
CacheSummary.PersistentCacheSizeMiB Member of StorageController.v1_0_0.StorageController
Description | The portion of the cache memory that is persistent, measured in MiB. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
CacheSummary.Status Member of StorageController.v1_0_0.StorageController See the Redfish standard schema and specification for information on common Status object.
CacheSummary.TotalCacheSizeMiB Member of StorageController.v1_0_0.StorageController
Description | The total configured cache memory, measured in MiB. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
ControllerRates
ControllerRates.ConsistencyCheckRatePercent Member of StorageController.v1_0_0.StorageController
Description | The percentage of controller resources used for performing a data consistency check on volumes. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
ControllerRates.RebuildRatePercent Member of StorageController.v1_0_0.StorageController
Description | The percentage of controller resources used for rebuilding/repairing volumes. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
ControllerRates.TransformationRatePercent Member of StorageController.v1_0_0.StorageController
Description | The percentage of controller resources used for transforming volumes from one configuration to another. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
FirmwareVersion
Member of StorageController.v1_0_0.StorageController
Description | The firmware version of this storage controller. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Identifiers (array)
Member of StorageController.v1_0_0.StorageController
Identifiers
is an array containing elements of:
Identifiers[{item}].DurableName Member of StorageController.v1_0_0.StorageController
Description | The world-wide, persistent name of the resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Identifiers[{item}].DurableNameFormat Member of StorageController.v1_0_0.StorageController
Description | The format of the durable name property. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NAA |
The Name Address Authority (NAA) format. |
iQN |
The iSCSI Qualified Name (iQN). |
FC_WWN |
The Fibre Channel (FC) World Wide Name (WWN). |
UUID |
The Universally Unique Identifier (UUID). |
EUI |
The IEEE-defined 64-bit Extended Unique Identifier (EUI). |
NQN |
The NVMe Qualified Name (NQN). |
NGUID |
The Namespace Globally Unique Identifier (NGUID). |
Location
Location.PartLocation Location.PartLocation.LocationOrdinalValue Member of StorageController.v1_0_0.StorageController
Description | The number that represents the location of the part. If LocationType is slot and this unit is in slot 2, the LocationOrdinalValue is 2. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Location.PartLocation.LocationType Member of StorageController.v1_0_0.StorageController
Description | The location types for PartLocation. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Slot |
The slot as the type of location. |
Bay |
The bay as the type of location. |
Connector |
The connector as the type of location. |
Socket |
The socket as the type of location. |
Embedded |
Embedded within a part. |
Location.PartLocation.Orientation Member of StorageController.v1_0_0.StorageController
Description | The orientation for the ordering of the part location ordinal value. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
FrontToBack |
The ordering for LocationOrdinalValue is front to back. |
BackToFront |
The ordering for the LocationOrdinalValue is back to front. |
TopToBottom |
The ordering for the LocationOrdinalValue is top to bottom. |
BottomToTop |
The ordering for LocationOrdinalValue is bottom to top. |
LeftToRight |
The ordering for the LocationOrdinalValue is left to right. |
RightToLeft |
The ordering for the LocationOrdinalValue is right to left. |
Location.PartLocation.Reference Member of StorageController.v1_0_0.StorageController
Description | The reference area for the location of the part. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Top |
The part is in the top of the unit. |
Bottom |
The part is in the bottom of the unit. |
Front |
The part is in the front of the unit. |
Rear |
The part is in the rear of the unit. |
Left |
The part is on the left side of of the unit. |
Right |
The part is on the right side of the unit. |
Middle |
The part is in the middle of the unit. |
Location.PartLocation.ServiceLabel Member of StorageController.v1_0_0.StorageController
Description | The label of the part location, such as a silk-screened name or a printed label. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Location.Placement Location.Placement.AdditionalInfo Member of StorageController.v1_0_0.StorageController
Description | Area designation or other additional info. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Location.Placement.Rack Member of StorageController.v1_0_0.StorageController
Description | The name of a rack location within a row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Location.Placement.RackOffset Member of StorageController.v1_0_0.StorageController
Description | The vertical location of the item, in terms of RackOffsetUnits. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Location.Placement.RackOffsetUnits Member of StorageController.v1_0_0.StorageController
Description | The type of rack unit in use. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OpenU |
A rack unit that is equal to 48 mm (1.89 in). |
EIA_310 |
A rack unit that is equal to 1.75 in (44.45 mm). |
Location.Placement.Row Member of StorageController.v1_0_0.StorageController
Description | The name of the row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Manufacturer
Member of StorageController.v1_0_0.StorageController
Description | The manufacturer of this storage controller. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Model
Member of StorageController.v1_0_0.StorageController
Description | The model number for the storage controller. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PCIeInterface
PCIeInterface.LanesInUse Member of StorageController.v1_0_0.StorageController
Description | This is the number of PCIe lanes in use by this device. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PCIeInterface.MaxLanes Member of StorageController.v1_0_0.StorageController
Description | This is the number of PCIe lanes supported by this device. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PCIeInterface.MaxPCIeType Member of StorageController.v1_0_0.StorageController
Description | The highest version of the PCIe specification supported by this device. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Gen1 |
A PCIe v1.0 slot. |
Gen2 |
A PCIe v2.0 slot. |
Gen3 |
A PCIe v3.0 slot. |
Gen4 |
A PCIe v4.0 slot. |
Gen5 |
A PCIe v5.0 slot. |
PCIeInterface.PCIeType Member of StorageController.v1_0_0.StorageController
Description | The version of the PCIe specification in use by this device. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Gen1 |
A PCIe v1.0 slot. |
Gen2 |
A PCIe v2.0 slot. |
Gen3 |
A PCIe v3.0 slot. |
Gen4 |
A PCIe v4.0 slot. |
Gen5 |
A PCIe v5.0 slot. |
PartNumber
Member of StorageController.v1_0_0.StorageController
Description | The part number for this storage controller. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SKU
Member of StorageController.v1_0_0.StorageController
Description | The SKU for this storage controller. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SerialNumber
Member of StorageController.v1_0_0.StorageController
Description | The serial number for this storage controller. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SpeedGbps
Member of StorageController.v1_0_0.StorageController
Description | The maximum speed of the storage controller’s device interface. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of StorageController.v1_0_0.StorageController See the Redfish standard schema and specification for information on common Status object.
SupportedControllerProtocols (array)
Member of StorageController.v1_0_0.StorageController
SupportedControllerProtocols
is an array containing elements of:
SupportedControllerProtocols[{item}] Member of StorageController.v1_0_0.StorageController
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
SAS |
Serial Attached SCSI. |
NVMe |
Non-Volatile Memory Express |
SATA |
Serial AT Attachment |
USB |
Universal Serial Bus |
PCIe |
PCI Express |
SupportedDeviceProtocols (array)
Member of StorageController.v1_0_0.StorageController
SupportedDeviceProtocols
is an array containing elements of:
SupportedDeviceProtocols[{item}] Member of StorageController.v1_0_0.StorageController
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
SAS |
Serial Attached SCSI. |
NVMe |
Non-Volatile Memory Express |
SATA |
Serial AT Attachment |
USB |
Universal Serial Bus |
PCIe |
PCI Express |
SupportedRAIDTypes (array)
Member of StorageController.v1_0_0.StorageController
SupportedRAIDTypes
is an array containing elements of:
SupportedRAIDTypes[{item}] Member of StorageController.v1_0_0.StorageController
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
RAID0 |
A placement policy where consecutive logical blocks of data are uniformly distributed across a set of independent storage devices without offering any form of redundancy. |
RAID1 |
A placement policy where each logical block of data is stored on more than one independent storage device. |
RAID3 |
A placement policy using parity-based protection where logical bytes of data are uniformly distributed across a set of independent storage devices and where the parity is stored on a dedicated independent storage device. |
RAID4 |
A placement policy using parity-based protection where logical blocks of data are uniformly distributed across a set of independent storage devices and where the parity is stored on a dedicated independent storage device. |
RAID5 |
A placement policy using parity-based protection for storing stripes of ‘n’ logical blocks of data and one logical block of parity across a set of ‘n+1’ independent storage devices where the parity and data blocks are interleaved across the storage devices. |
RAID6 |
A placement policy using parity-based protection for storing stripes of ‘n’ logical blocks of data and two logical blocks of independent parity across a set of ‘n+2’ independent storage devices where the parity and data blocks are interleaved across the storage devices. |
RAID10 |
A placement policy that creates a striped device (RAID 0) over a set of mirrored devices (RAID 1). |
RAID01 |
A data placement policy that creates a mirrored device (RAID 1) over a set of striped devices (RAID 0). |
RAID6TP |
A placement policy that uses parity-based protection for storing stripes of ‘n’ logical blocks of data and three logical blocks of independent parity across a set of ‘n+3’ independent storage devices where the parity and data blocks are interleaved across the storage devices. |
RAID1E |
A placement policy that uses a form of mirroring implemented over a set of independent storage devices where logical blocks are duplicated on a pair of independent storage devices so that data is uniformly distributed across the storage devices. |
RAID50 |
A placement policy that uses a RAID 0 stripe set over two or more RAID 5 sets of independent storage devices. |
RAID60 |
A placement policy that uses a RAID 0 stripe set over two or more RAID 6 sets of independent storage devices. |
RAID00 |
A placement policy that creates a RAID 0 stripe set over two or more RAID 0 sets. |
RAID10E |
A placement policy that uses a RAID 0 stripe set over two or more RAID 10 sets. |
RAID1Triple |
A placement policy where each logical block of data is mirrored three times across a set of three independent storage devices. |
RAID10Triple |
A placement policy that uses a striped device (RAID 0) over a set of triple mirrored devices (RAID 1Triple). |
None |
A placement policy with no redundancy at the device level. |
StorageControllerCollection.StorageControllerCollection
@odata.type: "#StorageControllerCollection.StorageControllerCollection"
A Collection of Storage resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/storage/{item}/controllers/ |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
StorageController |
Members (array)
Member of StorageControllerCollection.StorageControllerCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of StorageControllerCollection.StorageControllerCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of StorageControllerCollection.StorageControllerCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Task.v1_3_0.Task
@odata.type: "#Task.v1_3_0.Task"
The Task resource describes a specific Task scheduled by or being executed by a Redfish service’s Task Service.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/taskservice/tasks/{item} |
GET |
EndTime
Member of Task.v1_3_0.Task
Description | The date-time stamp that the task was last completed. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Messages (array)
Member of Task.v1_3_0.Task
Messages
is an array containing elements of:
Messages[{item}].Message Member of Task.v1_3_0.Task
Description | This is the human readable message, if provided. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Messages[{item}].MessageArgs (array)
Member of Task.v1_3_0.Task
MessageArgs
is an array containing elements of:
MessageArgs[{item}] Member of Task.v1_3_0.Task
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Messages[{item}].MessageId Member of Task.v1_3_0.Task
Description | This is the key for this message which can be used to look up the message in a message registry. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Messages[{item}].RelatedProperties (array)
Member of Task.v1_3_0.Task
RelatedProperties
is an array containing elements of:
RelatedProperties[{item}] Member of Task.v1_3_0.Task
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Messages[{item}].Resolution Member of Task.v1_3_0.Task
Description | Used to provide suggestions on how to resolve the situation that caused the error. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Messages[{item}].Severity Member of Task.v1_3_0.Task
Description | This is the severity of the event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
Payload
Payload.HttpHeaders (array)
Member of Task.v1_3_0.Task
HttpHeaders
is an array containing elements of:
HttpHeaders[{item}] Member of Task.v1_3_0.Task
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Payload.HttpOperation Member of Task.v1_3_0.Task
Description | The HTTP operation to perform to execute this Task. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Payload.JsonBody Member of Task.v1_3_0.Task
Description | This property contains the JSON payload to use in the execution of this Task. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Payload.TargetUri Member of Task.v1_3_0.Task
Description | The URI of the target for this task. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
StartTime
Member of Task.v1_3_0.Task
Description | The date-time stamp that the task was last started. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
TaskMonitor
Member of Task.v1_3_0.Task
Description | The URI of the Task Monitor for this task. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
TaskState
Member of Task.v1_3_0.Task
Description | The state of the task. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
New |
A new task. |
Starting |
Task is starting. |
Running |
Task is running normally. |
Suspended |
Task has been suspended. |
Interrupted |
Task has been interrupted. |
Pending |
Task is pending and has not started. |
Stopping |
Task is in the process of stopping. |
Completed |
Task has completed. |
Killed |
Task was terminated. |
Exception |
Task has stopped due to an exception condition. |
Service |
Task is running as a service. |
TaskStatus
Member of Task.v1_3_0.Task
Description | This is the completion status of the task. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
OK |
Normal. |
Warning |
A condition exists that requires attention. |
Critical |
A critical condition exists that requires immediate attention. |
TaskCollection.TaskCollection
@odata.type: "#TaskCollection.TaskCollection"
A Collection of Task resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/taskservice/tasks |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Task |
Members (array)
Member of TaskCollection.TaskCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of TaskCollection.TaskCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of TaskCollection.TaskCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
TaskService.v1_1_1.TaskService
@odata.type: "#TaskService.v1_1_1.TaskService"
The TaskService resource describes the Task service. It represents the properties for the service itself and has links to the actual list of tasks.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/taskservice |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Tasks |
Collection of Task |
CompletedTaskOverWritePolicy
Member of TaskService.v1_1_1.TaskService
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Manual |
Completed tasks are not automatically overwritten. |
Oldest |
Oldest completed tasks are overwritten. |
DateTime
Member of TaskService.v1_1_1.TaskService
Description | The current DateTime (with offset) setting that the task service is using. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
LifeCycleEventOnTaskStateChange
Member of TaskService.v1_1_1.TaskService
Description | Send an Event upon Task State Change. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
ServiceEnabled
Member of TaskService.v1_1_1.TaskService
Description | This indicates whether this service is enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of TaskService.v1_1_1.TaskService See the Redfish standard schema and specification for information on common Status object.
Tasks
This property references a resource of type Collection with a MemberType of TaskCollection.
Tasks is a link ("@odata.id": URI
) to another resource.
TelemetryService.v1_0_0.TelemetryService
@odata.type: "#TelemetryService.v1_0_0.TelemetryService"
The TelemetryService resource describes the Metrics Service.
Telemetry not supported on AMD platforms
Telemetry Service is supported only on Intel platform. On AMD systems, performing GET
on /redfish/v1/TelemetryService
will return 400 Error Operation not supported.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
MetricReports |
Collection of MetricReport |
MetricReportDefinitions |
Collection of MetricDefinition |
Triggers |
Collection of Triggers |
MaxReports
Member of TelemetryService.v1_0_0.TelemetryService
Description | The maximum number of metric reports supported by this service. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MetricDefinitions
A link to the collection of Metric Definitions.
MetricDefinitions is a link ("@odata.id": URI
) to another resource.
MetricReportDefinitions
A link to the collection of Metric Reports.
MetricReportDefinitions is a link ("@odata.id": URI
) to another resource.
MetricReports
A link to the collection of Metric Reports.
MetricReports is a link ("@odata.id": URI
) to another resource.
MinCollectionInterval
Member of TelemetryService.v1_0_0.TelemetryService
Description | The minimum time interval between collections supported by this service. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of TelemetryService.v1_0_0.TelemetryService See the Redfish standard schema and specification for information on common Status object.
SupportedCollectionFunctions (array)
Member of TelemetryService.v1_0_0.TelemetryService
SupportedCollectionFunctions
is an array containing elements of:
SupportedCollectionFunctions[{item}] Member of TelemetryService.v1_0_0.TelemetryService
Description | An operation to perform over the sample. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Average |
An averaging function. |
Maximum |
A maximum function. |
Minimum |
A minimum function. |
Summation |
A summation function. |
Triggers
A link to the collection of Triggers, which apply to metrics.
Triggers is a link ("@odata.id": URI
) to another resource.
Thermal.v1_7_1.Thermal
@odata.type: "#Thermal.v1_7_1.Thermal"
The Thermal resource describes the system thermal metrics. It represents the properties for temperature and cooling.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/thermal |
GET POST PATCH |
Fans (array)
Member of Thermal.v1_7_1.Thermal
Fans
is an array containing elements of:
Fans[{item}].@odata.id Member of Thermal.v1_7_1.Thermal
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Fans[{item}].CorrelatableID Member of Thermal.v1_7_1.Thermal
Description | The CorrelatableID for this fan. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].LowerThresholdCritical Member of Thermal.v1_7_1.Thermal
Description | Below normal range but not yet fatal. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].LowerThresholdFatal Member of Thermal.v1_7_1.Thermal
Description | Below normal range and is fatal. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].LowerThresholdNonCritical Member of Thermal.v1_7_1.Thermal
Description | Below normal range. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].MaximumValue Member of Thermal.v1_7_1.Thermal
Description | Maximum value for CurrentReading. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].MemberId Member of Thermal.v1_7_1.Thermal
Description | This is the identifier for the member within the collection. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].MinimumValue Member of Thermal.v1_7_1.Thermal
Description | Minimum value for CurrentReading. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].Oem.Hpe.HotPluggable Member of Thermal.v1_7_1.Thermal
Description | Indicates if the fan can be replaced while server is running. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].Oem.Hpe.IsLiquidCooling Member of Thermal.v1_7_1.Thermal
Description | Indicates that the device is Liquid cooling device or not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].Oem.Hpe.Location Member of Thermal.v1_7_1.Thermal
Description | Indicates the component (i.e. CPU, Memory, and Storage) that the fan is being used to cool. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
System |
System Board |
I/O Board |
CPU |
Memory |
Storage |
Removable Media |
Power Supply |
Ambient |
Chassis |
Bridge Board |
Exhaust |
Processor Bay |
IO Bay |
Blade Slot |
Virtual |
Fans[{item}].Oem.Hpe.Redundant Member of Thermal.v1_7_1.Thermal
Description | Indicates if the fan is in a redundant configuration. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].PhysicalContext Member of Thermal.v1_7_1.Thermal
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Room |
The room |
Intake |
The intake point of the chassis |
Exhaust |
The exhaust point of the chassis |
Front |
The front of the chassis |
Back |
The back of the chassis |
Upper |
The upper portion of the chassis |
Lower |
The lower portion of the chassis |
CPU |
A Processor (CPU) |
GPU |
A Graphics Processor (GPU) |
Backplane |
A backplane within the chassis |
SystemBoard |
The system board (PCB) |
PowerSupply |
A power supply |
VoltageRegulator |
A voltage regulator device |
StorageDevice |
A storage device |
NetworkingDevice |
A networking device |
ComputeBay |
Within a compute bay |
StorageBay |
Within a storage bay |
NetworkBay |
Within a networking bay |
ExpansionBay |
Within an expansion bay |
PowerSupplyBay |
Within a power supply bay |
Fans[{item}].Reading Member of Thermal.v1_7_1.Thermal
Description | The current speed of the fan. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].ReadingUnits Member of Thermal.v1_7_1.Thermal
Description | Units for the CurrentReading. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Null |
Percent |
Fans[{item}].Status Member of Thermal.v1_7_1.Thermal See the Redfish standard schema and specification for information on common Status object.
Fans[{item}].UpperThresholdCritical Member of Thermal.v1_7_1.Thermal
Description | Above normal range but not yet fatal. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].UpperThresholdFatal Member of Thermal.v1_7_1.Thermal
Description | Above normal range and is fatal. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].UpperThresholdNonCritical Member of Thermal.v1_7_1.Thermal
Description | Above normal range. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.FanPercentAdjust
Member of Thermal.v1_7_1.Thermal
Description | System-wide setting for fan +/- percentage adjustment. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.FanPercentMinimum
Member of Thermal.v1_7_1.Thermal
Description | System-wide setting for fan speed minimum percentage. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.ThermalConfiguration
Member of Thermal.v1_7_1.Thermal
Description | The value of this property selects the fan cooling method for the system. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
OptimalCooling |
|
IncreasedCooling |
|
MaximumCooling |
|
EnhancedCooling |
|
AcousticMode |
Edgeline-only option. Prioritizes minimizing noise from the enclosure. |
Status
Member of Thermal.v1_7_1.Thermal See the Redfish standard schema and specification for information on common Status object.
Temperatures (array)
Member of Thermal.v1_7_1.Thermal
Temperatures
is an array containing elements of:
Temperatures[{item}].@odata.id Member of Thermal.v1_7_1.Thermal
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Temperatures[{item}].CorrelatableID Member of Thermal.v1_7_1.Thermal
Description | The CorrelatableID for this temperature sensor. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].LowerThresholdCritical Member of Thermal.v1_7_1.Thermal
Description | Below normal range but not yet fatal. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].LowerThresholdFatal Member of Thermal.v1_7_1.Thermal
Description | Below normal range and is fatal. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].LowerThresholdNonCritical Member of Thermal.v1_7_1.Thermal
Description | Below normal range. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].MaximumValue Member of Thermal.v1_7_1.Thermal
Description | Maximum value for CurrentReading. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].MemberId Member of Thermal.v1_7_1.Thermal
Description | This is the identifier for the member within the collection. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].MinimumValue Member of Thermal.v1_7_1.Thermal
Description | Minimum value for CurrentReading. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].Oem.Hpe.CriticalTempUserThreshold Member of Thermal.v1_7_1.Thermal
Description | User provided temperature threshold value for the sensor that results in a critical alert. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].Oem.Hpe.LocationXmm Member of Thermal.v1_7_1.Thermal
Description | The location of the sensor, in millimeters, along the X axis from the logical reference point. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].Oem.Hpe.LocationYmm Member of Thermal.v1_7_1.Thermal
Description | The location of the sensor, in millimeters, along the Y axis from the logical reference point. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].Oem.Hpe.LocationZmm Member of Thermal.v1_7_1.Thermal
Description | The location of the sensor, in millimeters, along the Z axis from the logical reference point. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].Oem.Hpe.MainSensorName Member of Thermal.v1_7_1.Thermal
Description | Sensor name of main temperature sensor that has atleast one sub sensor |
Type | string |
Read Only | True |
Added | iLO6 1.20 |
Temperatures[{item}].Oem.Hpe.WarningTempUserThreshold Member of Thermal.v1_7_1.Thermal
Description | User provided temperature threshold value for the sensor that results in a warning alert. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].PhysicalContext Member of Thermal.v1_7_1.Thermal
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Room |
The room. |
Intake |
The air intake point or points or region of the chassis. |
Exhaust |
The air exhaust point or points or region of the chassis. |
LiquidInlet |
The liquid inlet point of the chassis. |
LiquidOutlet |
The liquid outlet point of the chassis. |
Front |
The front of the chassis. |
Back |
The back of the chassis. |
Upper |
The upper portion of the chassis. |
Lower |
The lower portion of the chassis. |
CPU |
A processor (CPU). |
CPUSubsystem |
The entire processor (CPU) subsystem. |
GPU |
A graphics processor (GPU). |
GPUSubsystem |
The entire graphics processor (GPU) subsystem. |
FPGA |
An FPGA. |
Accelerator |
An accelerator. |
ASIC |
An ASIC device, such as a networking chip or chipset component. |
Backplane |
A backplane within the chassis. |
SystemBoard |
The system board (PCB). |
PowerSupply |
A power supply. |
PowerSubsystem |
The entire power subsystem. |
VoltageRegulator |
A voltage regulator device. |
Rectifier |
A rectifier device. |
StorageDevice |
A storage device. |
NetworkingDevice |
A networking device. |
ComputeBay |
Within a compute bay. |
StorageBay |
Within a storage bay. |
NetworkBay |
Within a networking bay. |
ExpansionBay |
Within an expansion bay. |
PowerSupplyBay |
Within a power supply bay. |
Memory |
A memory device. |
MemorySubsystem |
The entire memory subsystem. |
Chassis |
The entire chassis. |
Fan |
A fan. |
CoolingSubsystem |
The entire cooling, or air and liquid, subsystem. |
Motor |
A motor. |
Transformer |
A transformer. |
ACUtilityInput |
An AC utility input. |
ACStaticBypassInput |
An AC static bypass input. |
ACMaintenanceBypassInput |
An AC maintenance bypass input. |
DCBus |
A DC bus. |
ACOutput |
An AC output. |
ACInput |
An AC input. |
TrustedModule |
A trusted module. |
Board |
A circuit board. |
Transceiver |
A transceiver. |
Battery |
A battery. |
Pump |
A pump. |
Temperatures[{item}].ReadingCelsius Member of Thermal.v1_7_1.Thermal
Description | The current reading of the temperature sensor. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].SensorNumber Member of Thermal.v1_7_1.Thermal
Description | A numerical identifier to represent the temperature sensor. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].Status Member of Thermal.v1_7_1.Thermal See the Redfish standard schema and specification for information on common Status object.
Temperatures[{item}].UpperThresholdCritical Member of Thermal.v1_7_1.Thermal
Description | Above normal range but not yet fatal. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].UpperThresholdFatal Member of Thermal.v1_7_1.Thermal
Description | Above normal range and is fatal. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].UpperThresholdNonCritical Member of Thermal.v1_7_1.Thermal
Description | The noncritical temperature threshold. |
Type | number or null |
Read Only | True |
Added | iLO6 1.05 |
Actions
HpeThermalExt.SetUserTempThreshold Member of Thermal.v1_7_1.Thermal The action to set a user defined threshold for a PCIe slot temperature sensor.
Parameters:
AlertType (string)
Alert type thrown when user defined temperature threshold is exceeded.
Value | Description |
---|---|
Critical | Generate a critical alert when user threshold exceeded. |
Warning | Generate a warning alert when user threshold exceeded. |
SensorNumber (integer)
Sensor number of the sensor to be monitored.
ThresholdValue (integer)
Temperature thershold that once passed will issue an alert.
Triggers.v1_0_0.Triggers
@odata.type: "#Triggers.v1_0_0.Triggers"
The Triggers resource describes the a metric trigger, which apply to metrics.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/triggers/{item} |
GET PATCH |
MetricProperties (array)
Member of Triggers.v1_0_0.Triggers
MetricProperties
is an array containing elements of:
MetricProperties[{item}] Member of Triggers.v1_0_0.Triggers
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MetricType
Member of Triggers.v1_0_0.Triggers
Description | Specifies the type of metric for which the trigger is configured. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Numeric |
The trigger is for numeric sensor. |
Discrete |
The trigger is for a discrete sensor. |
NumericThresholds
NumericThresholds.LowerCritical NumericThresholds.LowerCritical.Activation Member of Triggers.v1_0_0.Triggers
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
NumericThresholds.LowerCritical.DwellTime Member of Triggers.v1_0_0.Triggers
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
NumericThresholds.LowerCritical.Reading Member of Triggers.v1_0_0.Triggers
Description | The threshold value. |
Type | number or null |
Read Only | False |
Added | iLO6 1.05 |
NumericThresholds.LowerWarning NumericThresholds.LowerWarning.Activation Member of Triggers.v1_0_0.Triggers
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
NumericThresholds.LowerWarning.DwellTime Member of Triggers.v1_0_0.Triggers
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
NumericThresholds.LowerWarning.Reading Member of Triggers.v1_0_0.Triggers
Description | The threshold value. |
Type | number or null |
Read Only | False |
Added | iLO6 1.05 |
NumericThresholds.UpperCritical NumericThresholds.UpperCritical.Activation Member of Triggers.v1_0_0.Triggers
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
NumericThresholds.UpperCritical.DwellTime Member of Triggers.v1_0_0.Triggers
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
NumericThresholds.UpperCritical.Reading Member of Triggers.v1_0_0.Triggers
Description | The threshold value. |
Type | number or null |
Read Only | False |
Added | iLO6 1.05 |
NumericThresholds.UpperWarning NumericThresholds.UpperWarning.Activation Member of Triggers.v1_0_0.Triggers
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
NumericThresholds.UpperWarning.DwellTime Member of Triggers.v1_0_0.Triggers
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
NumericThresholds.UpperWarning.Reading Member of Triggers.v1_0_0.Triggers
Description | The threshold value. |
Type | number or null |
Read Only | False |
Added | iLO6 1.05 |
Status
Member of Triggers.v1_0_0.Triggers See the Redfish standard schema and specification for information on common Status object.
TriggerActions (array)
Member of Triggers.v1_0_0.Triggers
TriggerActions
is an array containing elements of:
TriggerActions[{item}] Member of Triggers.v1_0_0.Triggers
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
LogToLogService |
Upon a trigger, record in a log. |
RedfishEvent |
Upon a trigger, send a Redfish Event message of type MetricReport. |
TriggersCollection.TriggersCollection
@odata.type: "#TriggersCollection.TriggersCollection"
A Collection of Triggers resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/triggers |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Triggers |
Members (array)
Member of TriggersCollection.TriggersCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of TriggersCollection.TriggersCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of TriggersCollection.TriggersCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
UpdateService.v1_2_1.UpdateService
@odata.type: "#UpdateService.v1_2_1.UpdateService"
The UpdateService resource describes the Update Service. It represents the properties for the service itself and has links to collections of firmware and software inventory.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice |
GET POST PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Oem/Hpe/InstallSets |
Collection of HpeComponentInstallSet |
Oem/Hpe/ComponentRepository |
Collection of HpeComponent |
FirmwareInventory |
Collection of SoftwareInventory |
SoftwareInventory |
Collection of SoftwareInventory |
Oem/Hpe/UpdateTaskQueue |
Collection of HpeComponentUpdateTask |
FirmwareInventory
Link to Firmware Inventory.
FirmwareInventory is a link ("@odata.id": URI
) to another resource.
HttpPushUri
Member of UpdateService.v1_2_1.UpdateService
Description | The URI to which a client may POST an update image. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Oem.Hpe.Accept3rdPartyFirmware
Member of UpdateService.v1_2_1.UpdateService
Description | Enable or disable support for 3rd party firmware update packages. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.BundleUpdateReport
Link to the Bundle Update report.
BundleUpdateReport is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.Capabilities
Oem.Hpe.Capabilities.BundleDowngradeSupport Member of UpdateService.v1_2_1.UpdateService
Description | Indicates whether iLO supports downgrade capability for cloud based updates. |
Type | boolean |
Read Only | True |
Added | iLO6 1.10 |
Oem.Hpe.Capabilities.COMBootToUefiShellSupport Member of UpdateService.v1_2_1.UpdateService
Description | Indicates whether iLO supports booting to Uefi shell for cloud based updates. |
Type | boolean |
Read Only | True |
Added | iLO6 1.40 |
Oem.Hpe.Capabilities.COMVCSupport Member of UpdateService.v1_2_1.UpdateService
Description | Indicates whether iLO supports pending reset for bundle update. |
Type | boolean |
Read Only | True |
Added | iLO6 1.40 |
Oem.Hpe.Capabilities.OfflineRuntimeBundleUpdate Member of UpdateService.v1_2_1.UpdateService
Description | Indicates whether iLO supports offline type D installation. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ProductionMode |
iLO supports offline type D installation in production security state only. |
ProductionAndHighSecurityMode |
iLO supports offline type D installation in Production and High security state only. |
AllModes |
iLO supports offline type D installation in all security states viz, Production, High security, FIPS and CNSA. |
Oem.Hpe.Capabilities.PLDMFirmwareUpdate Member of UpdateService.v1_2_1.UpdateService
Description | Indicates whether iLO supports PLDM firmware updates. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Capabilities.UpdateFWPKG Member of UpdateService.v1_2_1.UpdateService
Description | Indicates whether iLO supports FWPKG 2.0 firmware images. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ComponentRepository
Link to the Component Repository.
ComponentRepository is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.CurrentTime
Member of UpdateService.v1_2_1.UpdateService
Description | ISO 8601 Redfish-style time string of the current iLO time (the reference for all scheduling) |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Oem.Hpe.DowngradePolicy
Member of UpdateService.v1_2_1.UpdateService
Description | Can be used to restrict the firmware downgrade. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
AllowDowngrade |
Downgrading firmware is allowed. |
RecoveryDowngrade |
Downgrading firmware is allowed by a user with the Recovery Set privilege. |
NoDowngrade |
Downgrading firmware is not allowed. This is a permanent setting and cannot be undone. |
Oem.Hpe.FirmwareIntegrity
Oem.Hpe.FirmwareIntegrity.EnableBackgroundScan Member of UpdateService.v1_2_1.UpdateService
Description | Enables or disables background scan of critical firmware. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.FirmwareIntegrity.LastFailedImageUri Member of UpdateService.v1_2_1.UpdateService
Description | This is a link to the binary image of the firmware that failed an integrity check and is intended for diagnostic purposes. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Oem.Hpe.FirmwareIntegrity.LastScanResult Member of UpdateService.v1_2_1.UpdateService
Description | The firmware integrity scan engine status. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
OK |
The last firmware integrity scan completed without finding any issues. |
Repaired |
The last firmware integrity scan successfully repaired an issue. Refer to the event log for details. |
Failure |
The last firmware integrity scan failed to complete or repair an issue. Refer to the event log for details. |
Stopped |
The last firmware integrity scan was stopped prior to completion. Refer to the event log for details. |
Oem.Hpe.FirmwareIntegrity.LastScanTime Member of UpdateService.v1_2_1.UpdateService
Description | The time stamp of the last firmware integrity scan. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Oem.Hpe.FirmwareIntegrity.OnIntegrityFailure Member of UpdateService.v1_2_1.UpdateService
Description | Sets the policy for how the firmware integrity check handles integrity failures. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
LogOnly |
Log failures to the iLO event log but do not automatically attempt to repair. |
LogAndRepairAutomatically |
Log failures to the iLO event log and automatically attempt to repair. |
Oem.Hpe.FirmwareIntegrity.ScanEveryDays Member of UpdateService.v1_2_1.UpdateService
Description | Sets the interval between firmware integrity scans in 24 hour increments. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.FlashProgressPercent
Member of UpdateService.v1_2_1.UpdateService
Description | This is the percent complete for an iLO flash operation. It is only valid when State is Updating. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.InstallSets
Link to the Install Sets collection.
InstallSets is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.InvalidImageRepository
Link to the Invalid Image Repository.
InvalidImageRepository is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.MaintenanceWindows
Link to the Maintenance Windows.
MaintenanceWindows is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.Result
Oem.Hpe.Result.MessageArgs (array)
Member of UpdateService.v1_2_1.UpdateService
MessageArgs
is an array containing elements of:
MessageArgs[{item}] Member of UpdateService.v1_2_1.UpdateService
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Result.MessageId Member of UpdateService.v1_2_1.UpdateService
Description | The key for this message that can be used to look up the message in a message registry. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.State
Member of UpdateService.v1_2_1.UpdateService
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Idle |
The update service is idle. |
Uploading |
The update service is receiving a new component. |
Verifying |
The update service is verifying the integrity of a new component. |
Writing |
The update service is writing a new component to the iLO Repository. |
Updating |
The update service is updating (flashing) firmware. |
Complete |
The update service has completed up upload or update operation. |
Error |
The upload service encountered an error. See Result for detail. |
Oem.Hpe.UpdateTaskQueue
Link to the Update Task Queue.
UpdateTaskQueue is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.UploadCurrentEtag
Member of UpdateService.v1_2_1.UpdateService
Description | client-supplied etag (during component upload) indicating to what UploadStatus is reporting upon. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
ServiceEnabled
Member of UpdateService.v1_2_1.UpdateService
Description | Indicates if the Update Service is enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
SoftwareInventory
Link to Software Inventory. This is only available when the Agentless Management Service is running.
SoftwareInventory is a link ("@odata.id": URI
) to another resource.
Actions
UpdateService.SimpleUpdate Member of UpdateService.v1_2_1.UpdateService
Parameters:
Username (string)
The username credential required for authentication to fetch image.
TransferProtocol (string)
Value | Description |
---|---|
HTTP | Hypertext Transfer Protocol |
HTTPS | HTTP Secure protocol |
ImageURI (string)
Password (string)
The password credential required for authentication to fetch image.
Targets (array)
Target Redfish URI
HpeiLOUpdateServiceExt.DeleteInstallSets Member of UpdateService.v1_2_1.UpdateService
Parameters:
IncludeRecoverySet (boolean)
HpeiLOUpdateServiceExt.DeleteUnlockedComponents Member of UpdateService.v1_2_1.UpdateService There are no parameters for this action.
HpeiLOUpdateServiceExt.DeleteMaintenanceWindows Member of UpdateService.v1_2_1.UpdateService There are no parameters for this action.
HpeiLOUpdateServiceExt.AddFromUri Member of UpdateService.v1_2_1.UpdateService
Parameters:
UpdateTarget (boolean)
If true the action will flash the target.
UpdateRecoverySet (boolean)
If true the action will update the system recovery set if it contains a matching target after the repository is updated.
UploadCurrentEtag (string)
client-supplied etag (during component upload) indicating to what UploadStatus is reporting upon.
VirtualMedia.v1_3_0.VirtualMedia
@odata.type: "#VirtualMedia.v1_3_0.VirtualMedia"
The VirtualMedia resource describes the BMC virtual media feature.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/virtualmedia/{item} |
GET POST PATCH |
ConnectedVia
Member of VirtualMedia.v1_3_0.VirtualMedia
Description | Specifies how the virtual media is connected to the server. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
NotConnected |
No current connection. |
URI |
Connected to a URI location. |
Applet |
Connected to a client application. |
Image
Member of VirtualMedia.v1_3_0.VirtualMedia
Description | The valid URI indicating the image that is mounted on this server. A null value indicates that no image exists. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Format | uri-reference |
ImageName
Member of VirtualMedia.v1_3_0.VirtualMedia
Description | The name of the image that is mounted on this server. This is usually provided when a URL image is mounted through scripted virtual media. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Inserted
Member of VirtualMedia.v1_3_0.VirtualMedia
Description | Indicates whether the virtual media is mounted on the server. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
MediaTypes (array)
Member of VirtualMedia.v1_3_0.VirtualMedia
MediaTypes
is an array containing elements of:
MediaTypes[{item}] Member of VirtualMedia.v1_3_0.VirtualMedia
Description | The array of supported media types for this connection. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
CD |
A CD-ROM format (ISO) image. |
Floppy |
A floppy disk image. |
USBStick |
An emulation of a USB storage device. |
DVD |
A DVD-ROM format image. |
Oem.Hpe.BootOnNextServerReset
Member of VirtualMedia.v1_3_0.VirtualMedia
Description | If set to true, the server will boot to this image on the next server reboot. The image will be ejected automatically on the second server reboot so that the server does not boot to this image twice. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
TransferProtocolType
Member of VirtualMedia.v1_3_0.VirtualMedia
Description | Network Protocol to use with the image |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
CIFS |
Common Internet File System protocol. |
FTP |
File Transfer Protocol. |
SFTP |
Secure File Transfer Protocol. |
HTTP |
Hypertext Transfer Protocol. |
HTTPS |
HTTP Secure protocol. |
NFS |
Network File System protocol. |
SCP |
Secure File Copy protocol. |
TFTP |
Trivial File Transfer Protocol. |
OEM |
A protocol defined by the manufacturer. |
WriteProtected
Member of VirtualMedia.v1_3_0.VirtualMedia
Description | Indicates whether the virtual media is protected against write operations. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Actions
VirtualMedia.InsertMedia Member of VirtualMedia.v1_3_0.VirtualMedia
Parameters:
TransferProtocolType (string)
Network Protocol to use with the image
Value | Description |
---|---|
FTP | File Transfer Protocol. |
HTTP | Hypertext Transfer Protocol. |
CIFS | Common Internet File System protocol. |
HTTPS | HTTP Secure protocol. |
SFTP | Secure File Transfer Protocol. |
NFS | Network File System protocol. |
OEM | A protocol defined by the manufacturer. |
TFTP | Trivial File Transfer Protocol. |
SCP | Secure File Copy protocol. |
Image (string)
The URI of the remote media to attach to the virtual media.
WriteProtected (boolean)
Indicates whether the virtual media is protected against write operations. If this parameter is not provided by the client, the service shall default this value to be true.
Inserted (boolean)
Indicates if the image is to be treated as inserted upon completion of the action. If this parameter is not provided by the client, the service shall default this value to be true.
VirtualMedia.EjectMedia Member of VirtualMedia.v1_3_0.VirtualMedia There are no parameters for this action.
HpeiLOVirtualMedia.InsertVirtualMedia Member of VirtualMedia.v1_3_0.VirtualMedia
Parameters:
Certificate (string)
A PEM encoded X509 certificate used to validate the https server.
Image (string)
A URL for an ISO, BIN, or IMG file locating the virtual media image.
Intent (string)
A text description of the reason for this action invocation.
Signature (string)
A RSA2048 SHA-256 signature validating the provided Intent (Base64 encoded).
WriteProtected (boolean)
Indicates whether the virtual media is protected against write operations.
HpeiLOVirtualMedia.EjectVirtualMedia Member of VirtualMedia.v1_3_0.VirtualMedia
Parameters:
Intent (string)
A text description of the reason for this action invocation.
Signature (string)
A RSA2048 SHA-256 signature validating the provided Intent (Base64 encoded).
VirtualMediaCollection.VirtualMediaCollection
@odata.type: "#VirtualMediaCollection.VirtualMediaCollection"
A Collection of VirtualMedia resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/virtualmedia |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
VirtualMedia |
Members (array)
Member of VirtualMediaCollection.VirtualMediaCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of VirtualMediaCollection.VirtualMediaCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of VirtualMediaCollection.VirtualMediaCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Volume.v1_0_0.Volume
@odata.type: "#Volume.v1_0_0.Volume"
The Volume resource describes a volume, virtual disk, LUN, or other logical storage entity for any system.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/storage/{item}/volumes/{item} |
GET POST PATCH DELETE |
Links to other Resources
Link Name | Destination type |
---|---|
Links/Drives[] |
Drive |
CapacityBytes
Member of Volume.v1_0_0.Volume
Description | The size in bytes of this Volume |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
DedicatedSpareDrives (array)
Member of Volume.v1_0_0.Volume
DedicatedSpareDrives
is an array containing elements of:
DedicatedSpareDrives[{item}].@odata.id Member of Volume.v1_0_0.Volume
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Status
Member of Volume.v1_0_0.Volume See the Redfish standard schema and specification for information on common Status object.
VolumeType
Member of Volume.v1_0_0.Volume
Description | The type of this volume. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
RawDevice |
The volume is a raw physical device without any RAID or other virtualization applied |
VolumeCollection.VolumeCollection
@odata.type: "#VolumeCollection.VolumeCollection"
A Collection of Volume resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/storage/{item}/volumes |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Volume |
Members (array)
Member of VolumeCollection.VolumeCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of VolumeCollection.VolumeCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of VolumeCollection.VolumeCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Response Message Definitions
API Responses are discussed in the section Handling Error Responses. The responses contain one or more “MessageId” properties each corresponding to an entry in a message registry. This section is a reference for the defined message registry entries.
Base.1.17.AccessDenied
While attempting to access, connect to, or transfer to/from another resource, the service was denied access.
Message Format | “While attempting to establish a connection to %1, the service was denied access.” |
Severity | Critical |
Resolution | Verify that the URI is correct and that the service has the appropriate credentials. |
Base.1.17.AccountForSessionNoLongerExists
The account for the current session is removed, and the current session is also removed.
Message Format | “The account for the current session is removed, and the current session is also removed.” |
Severity | OK |
Resolution | Attempt to connect using a valid account. |
Base.1.17.AccountModified
The account was modified successfully.
Message Format | “The account was modified successfully.” |
Severity | OK |
Resolution | None. |
Base.1.17.AccountNotModified
The request was unable to modify the account.
Message Format | “The account modification request did not complete.” |
Severity | Warning |
Resolution | If the operation did not complete, check the authorization or the request body for issues and resubmit the request. |
Base.1.17.AccountRemoved
The account was removed successfully.
Message Format | “The account was removed successfully.” |
Severity | OK |
Resolution | None. |
Base.1.17.ActionNotSupported
The action supplied in the POST operation is not supported by the resource.
Message Format | “The action %1 is not supported by the resource.” |
Severity | Critical |
Resolution | The action was invalid or the wrong resource was the target. See the implementation documentation for assistance. |
Base.1.17.ActionParameterDuplicate
The action was submitted with a duplicate parameter in the request body.
Message Format | “The action %1 was submitted with more than one value for the parameter %2.” |
Severity | Warning |
Resolution | Resubmit the action with only one instance of the parameter in the request body. |
Base.1.17.ActionParameterMissing
The requested action is missing a parameter that is required to process the action.
Message Format | “The action %1 requires that the parameter %2 be present in the request body.” |
Severity | Critical |
Resolution | Resubmit the action with the required parameter in the request body. |
Base.1.17.ActionParameterNotSupported
The action parameter is not supported on the target resource.
Message Format | “The parameter %1 for the action %2 is not supported on the target resource.” |
Severity | Warning |
Resolution | If the operation did not complete, remove the parameter and resubmit the request. |
Base.1.17.ActionParameterUnknown
An action was submitted, but a supplied parameter did not match any of the known parameters.
Message Format | “The action %1 was submitted with the invalid parameter %2.” |
Severity | Warning |
Resolution | If the operation did not complete, correct the invalid parameter and resubmit the request. |
Base.1.17.ActionParameterValueFormatError
The value type is correct, but the format is not supported or the size/length is exceeded.
Message Format | “The value %1 for the parameter %2 in the action %3 is in a format that is not supported by the parameter.” |
Severity | Warning |
Resolution | If the operation did not complete, correct the parameter value in the request body and resubmit the request. |
Base.1.17.ActionParameterValueTypeError
The parameter contains an incorrect value type. For example, a number value for a string parameter type.
Message Format | “The value %1 for the parameter %2 in the action %3 is the incorrect parameter type.” |
Severity | Warning |
Resolution | If the operation did not complete, correct the parameter value in the request body and resubmit the request. |
Base.1.17.AuthenticationTokenRequired
Indicates that the request could not be performed because an authentication token was not provided.
Message Format | “The request could not be performed because an authentication token was not provided.” |
Severity | Critical |
Resolution | Obtain an authentication token and resubmit the request. |
Base.1.17.CouldNotEstablishConnection
An attempt to access the resource, image, or file at the URI was unsuccessful because a session could not be established.
Message Format | “The service was unable to establish a connection with the URI %1.” |
Severity | Critical |
Resolution | Verify that the URI contains a valid and reachable node name, protocol information, and other URI components. |
Base.1.17.CreateFailedMissingReqProperties
A create operation was attempted on a resource, but a required property was missing from the request.
Message Format | “The create operation did not complete because the required property %1 was missing from the request.” |
Severity | Critical |
Resolution | If the operation did not complete, include the required property with a valid value in the request body and resubmit the request. |
Base.1.17.CreateLimitReachedForResource
Additional resources cannot be created.
Message Format | “Additional resources cannot be created.” |
Severity | Critical |
Resolution | If the operation did not complete, delete resources and resubmit the request. |
Base.1.17.Created
The resource has been created successfully.
Message Format | “The resource has been created successfully.” |
Severity | OK |
Resolution | None |
Base.1.17.EmptyJSON
Indicates that the request body contained an empty JSON object when one or more properties are expected in the body.
Message Format | “The request body submitted contained an empty JSON object and the service is unable to process it.” |
Severity | Warning |
Resolution | Add properties in the JSON object and resubmit the request. |
Base.1.17.EventSubscriptionLimitExceeded
The event subscription establishment has been requested, but the operation did not complete. The number of simultaneous subscriptions exceeded the maximum number allowed by the implementation.
Message Format | “The event subscription did not complete because the number of simultaneous subscriptions exceeded the maximum number allowed by the implementation.” |
Severity | Critical |
Resolution | Before attempting to establish the event subscription, reduce the number of subscriptions or increase the maximum number of simultaneous subscriptions allowed (if supported). |
Base.1.17.GeneralError
Indicates that a general error has occurred. Use in ExtendedInfo is discouraged. When used in ExtendedInfo, implementations are expected to include a Resolution property with this error to indicate how to resolve the problem.
Message Format | “A general error has occurred. See Resolution for information on how to resolve the error.” |
Severity | Critical |
Resolution | None. |
Base.1.17.InsufficientPrivilege
The account or credentials associated with the current session are not authorized to perform the requested operation.
Message Format | “The account or credentials associated with the current session are not authorized to perform the requested operation.” |
Severity | Critical |
Resolution | Retry the operation with an authorized account or credentials. |
Base.1.17.InternalError
The request did not complete due to an unknown internal error, but the service is still operational.
Message Format | “The request failed due to an internal service error, but the service is still operational.” |
Severity | Critical |
Resolution | Resubmit the request. If the problem persists, consider resetting the service. |
Base.1.17.InvalidIndex
The Index is not valid.
Message Format | “The Index %1 is not a valid offset into the array.” |
Severity | Warning |
Resolution | Verify the index value provided is within the bounds of the array. |
Base.1.17.InvalidObject
The object is not valid.
Message Format | “The object at %1 is not valid.” |
Severity | Critical |
Resolution | If the operation did not complete, the object is malformed or the URI is incorrect. Make the appropriate corrections and resubmit the request. |
Base.1.17.MalformedJSON
The request body contains malformed JSON.
Message Format | “The request body submitted is malformed JSON and cannot be parsed by the receiving service.” |
Severity | Critical |
Resolution | Verify that the request body is valid JSON and resubmit the request. |
Base.1.17.NoOperation
Indicates that the requested operation will not perform any changes on the service.
Message Format | “The request body submitted contain no data to act upon and no changes to the resource took place.” |
Severity | Warning |
Resolution | Add properties in the JSON object and resubmit the request. |
Base.1.17.NoValidSession
The operation did not complete because a valid session is required in order to access resources.
Message Format | “There is no valid session established with the implementation.” |
Severity | Critical |
Resolution | Establish a session before attempting any operations. |
Base.1.17.OneTimePasscodeSent
Indicates that a required one-time passcode has been sent to the user. The code should be provided as the Token
in the request to create a Session.
Message Format | “A one-time passcode has been sent to: %1 Supply the passcode as the Token in the request to create a Session.” |
Severity | OK |
Resolution | Obtain the one-time passcode sent to the delivery address and resubmit the request using the passcode as the Token. |
Base.1.17.PropertyDuplicate
A duplicate property is in the request body.
Message Format | “The property %1 is duplicated in the request.” |
Severity | Warning |
Resolution | If the operation did not complete, remove the duplicate property from the request body and resubmit the request. |
Base.1.17.PropertyMissing
The request does not include a required property.
Message Format | “The property %1 is a required property and must be included in the request.” |
Severity | Warning |
Resolution | If the operation did not complete, verify the property is in the request body and has a valid value. |
Base.1.17.PropertyNotWritable
The request included a value for a read-only property.
Message Format | “The property %1 is a read-only property and cannot be assigned a value.” |
Severity | Warning |
Resolution | If the operation did not complete, remove the property from the request body and resubmit the request. |
Base.1.17.PropertyUnknown
An unknown property is in the request body.
Message Format | “The property %1 is not valid for this resource.” |
Severity | Warning |
Resolution | If the operation did not complete, remove the unknown property from the request body and resubmit the request. |
Base.1.17.PropertyValueFormatError
The value type is correct, but the format is not supported or the size/length is exceeded.
Message Format | “The value %1 for the property %2 is in a format that is not supported by the property.” |
Severity | Warning |
Resolution | If the operation did not complete, correct the property value in the request body and resubmit the request. |
Base.1.17.PropertyValueModified
Indicates that a property was given the correct value type but the value of that property was modified. Examples are truncated or rounded values.
Message Format | “The property %1 was assigned the value %2 due to modification by the service.” |
Severity | Warning |
Resolution | No resolution is required. |
Base.1.17.PropertyValueNotInList
The value type is correct, but the value is not supported.
Message Format | “The value %1 for the property %2 is not valid.” |
Severity | Warning |
Resolution | If the operation did not complete, choose a value from the enumeration list and resubmit your request. |
Base.1.17.PropertyValueTypeError
The property value contains an incorrect property type. For example, a number value for a string property type.
Message Format | “The value %1 for the property %2 is the incorrect property type.” |
Severity | Warning |
Resolution | If the operation did not complete, correct the property value in the request body and resubmit the request. |
Base.1.17.QueryNotSupported
The query is not supported by the implementation.
Message Format | “Querying is not supported by the implementation.” |
Severity | Warning |
Resolution | If the operation did not complete, remove the query parameter and resubmit the request. |
Base.1.17.QueryNotSupportedOnResource
The query is not supported on the resource. For example, a start/count query is attempted on a resource that is not a collection.
Message Format | “Querying is not supported on the requested resource.” |
Severity | Warning |
Resolution | If the operation did not complete, remove the query parameters and resubmit the request. |
Base.1.17.QueryParameterOutOfRange
The query parameter value is out of range for the resource. For example, a page is requested that is outside the valid page range.
Message Format | “The value %1 for the query parameter %2 is out of range %3.” |
Severity | Warning |
Resolution | Specify a query parameter value that is within range. For example, a page that is within the valid range of pages. |
Base.1.17.QueryParameterValueError
Indicates that a query parameter was given an invalid value.
Message Format | “The value for the parameter %1 is invalid.” |
Severity | Warning |
Resolution | Correct the value for the query parameter in the request and resubmit the request if the operation failed. |
Base.1.17.QueryParameterValueFormatError
The value type is correct, but the format is not supported or the size/length was exceeded.
Message Format | “The value %1 for the parameter %2 is in a format that is not supported by the parameter.” |
Severity | Warning |
Resolution | If the operation did not complete, correct the value for the query parameter in the request body and resubmit the request. |
Base.1.17.QueryParameterValueTypeError
The query parameter contains an incorrect value type. For example, a number supplied for a query parameter that requires a string.
Message Format | “The value %1 for the query parameter %2 is the incorrect type of value for the query parameter.” |
Severity | Warning |
Resolution | If the operation did not complete, correct the value for the query parameter in the request body and resubmit the request. |
Base.1.17.ResourceAlreadyExists
Indicates that a resource change or creation was attempted but that the operation cannot proceed because the resource already exists.
Message Format | “The requested resource of type %1 with the property %2 with the value %3 already exists.” |
Severity | Critical |
Resolution | Do not repeat the create operation as the resource has already been created. |
Base.1.17.ResourceAtUriInUnknownFormat
The URI is valid, but the resource or image at that URI is in a format that is not supported by the service.
Message Format | “The resource at %1 is in a format that is not supported by the service.” |
Severity | Critical |
Resolution | Place a resource, image, or file that is supported by the service at the URI. |
Base.1.17.ResourceAtUriUnauthorized
An attempt to access the resource, image, or file at the URI is unauthorized.
Message Format | “While accessing the resource at %1, the service received an authorization error %2.” |
Severity | Critical |
Resolution | Verify that the appropriate access is provided for the service to access the URI. |
Base.1.17.ResourceCannotBeDeleted
A delete operation was attempted on a resource that cannot be deleted.
Message Format | “The delete request did not complete because the resource cannot be deleted.” |
Severity | Critical |
Resolution | Do not attempt to delete a resource that does not support the REST API DELETE operation. |
Base.1.17.ResourceExhaustion
Indicates that a resource could not satisfy the request due to some unavailability of resources. An example is that available capacity has been allocated.
Message Format | “The resource %1 was unable to satisfy the request due to unavailability of resources.” |
Severity | Critical |
Resolution | Ensure that the resources are available and resubmit the request. |
Base.1.17.ResourceInStandby
Indicates that the request could not be performed because the resource is in standby.
Message Format | “The request could not be performed because the resource is in standby.” |
Severity | Critical |
Resolution | Ensure that the resource is in the correct power state and resubmit the request. |
Base.1.17.ResourceInUse
The request to change the resource was rejected because the resource was in use or in transition.
Message Format | “The change to the resource did not complete because the resource is in use or in transition.” |
Severity | Warning |
Resolution | If the operation did not complete, wait until the resource is free and resubmit the request. |
Base.1.17.ResourceMissingAtURI
The operation expected an image or resource at the provided URI, but found none.
Message Format | “The resource at the URI %1 was not found.” |
Severity | Critical |
Resolution | Place a valid resource at the URI or correct the URI and resubmit the request. |
Base.1.17.ResourceNotFound
Indicates that the operation expected a resource identifier that corresponds to an existing resource but one was not found.
Message Format | “The requested resource of type %1 named %2 was not found.” |
Severity | Critical |
Resolution | Provide a valid resource identifier and resubmit the request. |
Base.1.17.ResourceTypeIncompatible
Indicates that the resource type of the operation does not match that for the operation destination. Examples of when this can happen include during a POST to a collection using the wrong resource type, an update where the @odata.types do not match or on a major version incompatability.
Message Format | “The @odata.type of the request body %1 is incompatible with the @odata.type of the resource which is %2.” |
Severity | Critical |
Resolution | Resubmit the request with a payload compatible with the resource’s schema. |
Base.1.17.ServiceInUnknownState
The operation did not complete because the service is in an unknown state and cannot take incoming requests.
Message Format | “The operation did not complete because the service is in an unknown state and cannot take incoming requests.” |
Severity | Critical |
Resolution | If the operation did not complete, restart the service and resubmit the request. |
Base.1.17.ServiceShuttingDown
The operation did not complete because the service is shutting down.
Message Format | “The operation did not complete because the service is shutting down and cannot take incoming requests.” |
Severity | Critical |
Resolution | If the operation did not complete, resubmit the request when the service is available. |
Base.1.17.ServiceTemporarilyUnavailable
The service is temporarily unavailable.
Message Format | “The service is temporarily unavailable. Retry in %1 seconds.” |
Severity | Critical |
Resolution | Wait for the indicated retry duration and retry the operation. |
Base.1.17.SessionLimitExceeded
Session establishment has been requested, but the operation did not complete because the number of simultaneous sessions exceeded the maximum number allowed by the implementation.
Message Format | “The session establishment did not complete because the number of simultaneous sessions exceeded the maximum number allowed by the implementation.” |
Severity | Critical |
Resolution | Before attempting to establish the session, reduce the number of sessions or increase the maximum number of simultaneous sessions allowed (if supported). |
Base.1.17.SessionTerminated
Indicates that the DELETE operation on the Session resource resulted in the successful termination of the session.
Message Format | “The session was successfully terminated.” |
Severity | OK |
Resolution | No resolution is required. |
Base.1.17.SourceDoesNotSupportProtocol
While attempting to access, connect to, or transfer from another location, the other end of the connection did not support the specified protocol.
Message Format | “The other end of the connection at %1 does not support the specified protocol %2.” |
Severity | Critical |
Resolution | Change protocols or URIs. |
Base.1.17.StringValueTooLong
Indicates that a string value passed to the given resource exceeded its length limit. An example is when a shorter limit is imposed by an implementation than that allowed by the specification.
Message Format | “The string %1 exceeds the length limit %2.” |
Severity | Warning |
Resolution | Resubmit the request with an appropriate string length. |
Base.1.17.Success
The operation completed successfully.
Message Format | “The operation completed successfully.” |
Severity | OK |
Resolution | None |
Base.1.17.UnrecognizedRequestBody
The service detected a request body with malformed JSON.
Message Format | “The service detected a request body with malformed JSON.” |
Severity | Warning |
Resolution | If the operation did not complete, correct the request body and resubmit the request. |
HpeCommon.2.1.ArrayPropertyOutOfBound
The items in the array exceed the maximum number supported.
Message Format | “An array %1 was supplied with %2 items that exceeds the maximum supported count of %3.” |
Severity | Warning |
Resolution | Retry the operation using the correct number of items for the array. |
HpeCommon.2.1.ConditionalSuccess
A property value was successfully changed but the change may be reverted upon system reset.
Message Format | “The property %1 was successfully changed to %2, but the change may be reverted upon system reset.” |
Severity | Warning |
Resolution | Check the “SettingsResult” messages after the system has reset for errors referring to the corresponding property. |
HpeCommon.2.1.InternalErrorWithParam
The operation was not successful due to an internal service error (shown), but the service is still operational.
Message Format | “The operation was not successful due to an internal service error (%1), but the service is still operational.” |
Severity | Critical |
Resolution | Retry the operation. If the problem persists, consider resetting the service. |
HpeCommon.2.1.InvalidConfigurationSpecified
The specified configuration is not valid.
Message Format | “The specified configuration is not valid.” |
Severity | Warning |
Resolution | Correct the configuration, and then retry the operation. |
HpeCommon.2.1.PropertyValueExceedsMaxLength
The value for the property exceeds the maximum length.
Message Format | “The value %1 for the property %2 exceeds the maximum length of %3.” |
Severity | Warning |
Resolution | Correct the value for the property in the request body, and then retry the operation. |
HpeCommon.2.1.PropertyValueIncompatible
The value for the property is the correct type, but this value is incompatible with the current value of another property.
Message Format | “The value %1 for the property %2 is incompatible with the value for property %3.” |
Severity | Warning |
Resolution | Correct the value for the property in the request body, and then retry the operation. |
HpeCommon.2.1.PropertyValueOutOfRange
The value for the property is out of range.
Message Format | “The value %1 for the property %2 is out of range %3.” |
Severity | Warning |
Resolution | Correct the value for the property in the request body, and then retry the operation. |
HpeCommon.2.1.ResetInProgress
A device or service reset is in progress.
Message Format | “A reset on %1 is in progress.” |
Severity | Warning |
Resolution | Wait for device or service reset to complete, and then retry the operation. |
HpeCommon.2.1.ResetRequired
One or more properties were changed, but these changes will not take effect until the device or service is reset.
Message Format | “One or more properties were changed, but these changes will not take effect until %1 is reset.” |
Severity | Warning |
Resolution | To enable the changed properties, reset the device or service. |
HpeCommon.2.1.ResourceNotReadyRetry
The resource is present but is not ready to perform operations due to an internal condition such as initialization or reset.
Message Format | “The resource is present but is not ready to perform operations. The resource will be ready in %1 seconds.” |
Severity | Warning |
Resolution | Retry the operation when the resource is ready. |
HpeCommon.2.1.SuccessFeedback
The operation completed successfully
Message Format | “The operation completed successfully” |
Severity | OK |
Resolution | None |
HpeCommon.2.1.TaskCreated
A task was created in response to the operation.
Message Format | “A task was created in response to the operation and is accessible at %1.” |
Severity | OK |
Resolution | Perform an HTTP GET request on the supplied URI for task status. |
HpeCommon.2.1.UnsupportedHwConfiguration
A previously requested property value change was reverted because the current hardware configuration does not support it.
Message Format | “The value %1 for property %2 was reverted because the current hardware configuration does not support it.” |
Severity | Warning |
Resolution | Ensure that the system’s hardware configuration supports the property value. |
iLO.2.21.AHSDisabled
Modifying AHS properties is not possible with AHS disabled.
Message Format | “Modifying AHS properties is not possible with AHS disabled.” |
Severity | Warning |
Resolution | Enable AHS, and then modify the AHS properties. |
iLO.2.21.Accepted
Indicates that one or more properties were correctly changed, but may not be in effect yet.
Message Format | “Indicates that one or more properties were correctly changed, but may not be in effect yet.” |
Severity | OK |
Resolution | None |
iLO.2.21.ActionParameterValueNotInList
Indicates that the correct value type was supplied for the action parameter, but the value is not supported. (The value is not in the enumeration list.)
Message Format | “The value %1 for the property %2 is not in the list of valid values.” |
Severity | Warning |
Resolution | Choose a value from the enumeration list and resubmit the request if the operation failed. |
iLO.2.21.AlertDestinationAssociationError
AlertDestination cannot be configured with both SNMPv1 and SNMPv3.
Message Format | “AlertDestination cannot be configured with both SNMPv1 and SNMPv3.” |
Severity | Warning |
Resolution | For SNMPv1 alert, configure SNMPAlertProtocol to SNMPv1. For SNMPv3 alert, configure SNMPAlertProtocol to SNMPv3. |
iLO.2.21.AlertMailFeatureDisabled
AlertMail feature is disabled.
Message Format | “AlertMail feature is disabled.” |
Severity | Warning |
Resolution | Enable AlertMail feature to send test alert message. |
iLO.2.21.AlreadyInProgress
An operation is already in progress.
Message Format | “An operation is already in progress.” |
Severity | Warning |
Resolution | Wait for the current operation to complete, and then retry the operation. |
iLO.2.21.AlreadyUpToDate
The update did not occur because the component was already up to date.
Message Format | “The update did not occur because the component was already up to date.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.ApmPowerCapModeInUsed
Operation is currently unavailable because the power regulator is set to APM Power Capping Mode.
Message Format | “Operation is currently unavailable because the power regulator is set to APM Power Capping Mode.” |
Severity | Warning |
Resolution | Change the power regulator to other modes rather than APM Power Capping Mode through APM interface. |
iLO.2.21.ArrayPropertyAlreadyExists
Duplicate value.
Message Format | “The property value %1 is already exists in index %2” |
Severity | Warning |
Resolution | If the operation did not complete, correct the property value in the request body and resubmit the request. |
iLO.2.21.ArrayPropertyOutOfBound
The number of items in the array exceeds the maximum number supported.
Message Format | “An array %1 was supplied with %2 items that does not meet the minimum supported count of %3 or exceeds the maximum supported count of %4.” |
Severity | Warning |
Resolution | Retry the operation using the correct number of items for the array. |
iLO.2.21.ArrayPropertyValueBadParam
The property value is not valid.
Message Format | “The property value %1 in index %2 is not valid.” |
Severity | Warning |
Resolution | Retry the operation using a corrected value. |
iLO.2.21.AuthenticationTokenExpired
Indicates that the request could not be performed because an authentication token was expired.
Message Format | “The request could not be performed because an authentication token was expired.” |
Severity | Critical |
Resolution | Obtain an authentication token and resubmit the request. |
iLO.2.21.BatteryBackupUnitSettingsDisabled
Battery Backup Unit settings are currently disabled.
Message Format | “Battery Backup Unit settings are disabled when the system is configured for Scalable Persistent Memory.” |
Severity | Warning |
Resolution | To re-enable Battery Backup Unit settings, disable Scalable Persistent Memory functionality in the system ROM RBSU. |
iLO.2.21.BiosActionTBD
The BIOS action supplied in the POST operation is not yet implemented.
Message Format | “The BIOS action %1 is not implemented yet.” |
Severity | Critical |
Resolution | The action was invalid or the wrong resource was the target. See the implementation documentation for assistance. |
iLO.2.21.BiosPasswordInfoInvalid
The stored BIOS password information is invalid. A system reboot is necessary to restore password defaults.
Message Format | “The stored BIOS password information is invalid. Reboot system.” |
Severity | Critical |
Resolution | The system will need to be rebooted to restore BIOS password information to defaults. |
iLO.2.21.BiosPasswordMismatch
The provided OldPassword does not match the stored BIOS password.
Message Format | “The provided OldPassword does not match the stored BIOS password.” |
Severity | Critical |
Resolution | Retry the action with the matching password. |
iLO.2.21.BundleUpdateAlreadyInProgress
A component upload operation is already in progress.
Message Format | “A component upload operation is already in progress.” |
Severity | Warning |
Resolution | Wait for the current upload to complete, and then retry the operation. |
iLO.2.21.BundleUpdateComponentDownloadFailed
Download of bundle update component failed.
Message Format | “Component %1 download download failed, reason %2. Bundle update aborted.” |
Severity | OK |
Resolution | None. |
iLO.2.21.BundleUpdateComponentDownloadStatus
Bundle update download status of components.
Message Format | “Component %1 download %2. %3 out of %4 downloaded” |
Severity | OK |
Resolution | None. |
iLO.2.21.BundleUpdateComponentInstallationFailed
Installation of bundle update component failed.
Message Format | “Component %1 installation failed, reason %2. Bundle update aborted.” |
Severity | OK |
Resolution | None. |
iLO.2.21.BundleUpdateComponentInstallationStatus
Bundle update component installation status.
Message Format | “Component %1 installation %2. %3 out of %4 installed.” |
Severity | OK |
Resolution | None. |
iLO.2.21.BundleUpdateInstallSetCreationFailed
Failed to create bundle update install set.
Message Format | “Install set %1 creation failed, reason %2. Bundle update aborted.” |
Severity | OK |
Resolution | None. |
iLO.2.21.BundleUpdateInstallSetCreationSuccess
Bundle update install set created successfully.
Message Format | “Install set %1 created successfully” |
Severity | OK |
Resolution | None. |
iLO.2.21.BundleUpdateInstallSetMetaDownloadFailed
Download of install set meta file failed.
Message Format | “Install set meta file %1 download failed, reason %2. Bundle update aborted.” |
Severity | OK |
Resolution | None. |
iLO.2.21.BundleUpdateInstallSetMetaDownloadStatus
Download status of install set meta file.
Message Format | “Install set meta file %1 download %2” |
Severity | OK |
Resolution | None. |
iLO.2.21.BundleUpdateInstallSetMetaProcessingFailed
Failed to process bundle update install set meta file.
Message Format | “Install set meta file %1 processing failed, reason %2. Bundle update aborted.” |
Severity | OK |
Resolution | None. |
iLO.2.21.BundleUpdateInstallSetMetaProcessingSuccess
Bundle update install set meta file processed successfully.
Message Format | “Install set meta file %1 processed successfully” |
Severity | OK |
Resolution | None. |
iLO.2.21.BundleUpdateInvalidUrl
The Url passed for bundle update is not valid.
Message Format | “The Url %1 is not valid.” |
Severity | Warning |
Resolution | URL is incorrect. Provide a valid URL and resubmit the request. |
iLO.2.21.BundleUpdateResetComplete
Server Reset complete.
Message Format | “Server Reset complete.” |
Severity | Warning |
Resolution | iLO Pending Reset is performed. |
iLO.2.21.BundleUpdateResetFailed
Pending Reset task failed.
Message Format | “Pending Reset task failed.” |
Severity | Warning |
Resolution | Bundle update Reset failed, Check the CA for more info. |
iLO.2.21.BundleUpdateResetPending
Waiting for Server Reset
Message Format | “Waiting for Server Reset” |
Severity | Warning |
Resolution | Reset the iLO to apply the changes. |
iLO.2.21.BundleUpdateSuccess
The status of bundle update installation.
Message Format | “Bundle update has completed successfully.” |
Severity | OK |
Resolution | None. |
iLO.2.21.COMActivationDenied
System already managed by an external manager.
Message Format | “System already managed by %1.” |
Severity | Warning |
Resolution | System can either be managed by HPE OneView or Compute Ops Manager. |
iLO.2.21.CalibrateInProgress
Power calibrate is in progress.
Message Format | “Power calibrate is in progress.” |
Severity | Warning |
Resolution | Wait for previous power calibrate complete or stop previous power calibrate, and then retry the operation. |
iLO.2.21.CannotRemoveDefaultLanguagePack
Cannot remove default language pack.
Message Format | “Cannot remove default language pack.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.CannotRemoveLanguagePack
Cannot remove language pack.
Message Format | “Cannot remove %1 language pack.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.CannotRemoveLicense
Cannot remove the base license.
Message Format | “The base license cannot be removed.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.ChassisPowerDataUnAvailable
Chassis power regulation data is currently unavailable.
Message Format | “Chassis power regulation data is currently unavailable.” |
Severity | Warning |
Resolution | Reset the management processor or chassis manager, and then retry the operation. |
iLO.2.21.ChassisResetRequired
The chassis properties were correctly changed, but will not take effect until the chassis is reset or all nodes in chassis remain powered off for at least 5 seconds.
Message Format | “One or more properties were changed and will not take effect until chassis is reset or all nodes in chassis remain powered off for at least 5 seconds.” |
Severity | Warning |
Resolution | Reset chassis or remain power off for all nodes in chassis for at least 5 seconds for the settings to take effect. |
iLO.2.21.ComponentUploadAlreadyInProgress
A component upload operation is already in progress.
Message Format | “A component upload operation is already in progress.” |
Severity | Warning |
Resolution | Wait for the current component upload to complete, and then retry the operation. |
iLO.2.21.ComponentUploadFailed
A component upload operation failed.
Message Format | “A component upload operation failed.” |
Severity | Warning |
Resolution | Wait for the current component upload to complete, and then retry the operation. |
iLO.2.21.DailyUpdateLimitExceeded
An update operation failed due to exceeding a daily limit.
Message Format | “An update operation failed due to exceeding a daily limit.” |
Severity | Warning |
Resolution | Retry the operation at a later date. |
iLO.2.21.DemoLicenseKeyPreviouslyInstalled
A license was previously activated and now a demo key may not be used.
Message Format | “A license was previously activated.” |
Severity | Warning |
Resolution | The system is no longer eligible for demo licenses. |
iLO.2.21.DeniedHPEOneViewUserCreation
System already managed by Compute Ops Management.
Message Format | “System already managed by %1.” |
Severity | OK |
Resolution | System can either be managed by HPE OneView or Compute Ops Management. |
iLO.2.21.DeviceIsBusy
Device was not available for communication.
Message Format | “Device communication response was busy.” |
Severity | Warning |
Resolution | Retry the attempted operation after a delay. |
iLO.2.21.DeviceResetRequired
Indicates that one or more properties were correctly changed, but will not take effect until device is reset.
Message Format | “One or more properties were changed and will not take effect until the device is reset.” |
Severity | Warning |
Resolution | Reset the device for the settings to take effect. |
iLO.2.21.DiagsTestAlreadyRunning
A diagnostics self test is already running.
Message Format | “A diagnostics self test is already running.” |
Severity | Warning |
Resolution | Stop the running test and try again. |
iLO.2.21.DowngradeNotAllowed
The task did not execute because a downgrade is not allowed by policy.
Message Format | “The task did not execute because a downgrade is not allowed by policy.” |
Severity | Warning |
Resolution | Obtain the latest available component and retry, and clear the task from the queue so processing can continue. |
iLO.2.21.DowngradePolicyAlreadySet
The downgrade policy has been set and cannot be changed.
Message Format | “The downgrade policy has been set and cannot be changed.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.ESKMServersNotConfigured
Enterprise Secure Key Manager Servers are not configured.
Message Format | “Enterprise Secure Key Manager Servers are not configured.” |
Severity | OK |
Resolution | None. |
iLO.2.21.ESXioOrTarImageDownloadAlreadyInProgress
ESXio or tar image download is already in progress.
Message Format | “ESXio or tar image download is already in progress.” |
Severity | Warning |
Resolution | Wait for the current operation to complete, and then retry the operation. |
iLO.2.21.ETagTooLong
The supplied ETag is too long. The maximum supported ETag length is 63 bytes.
Message Format | “The supplied ETag is too long. The maximum supported ETag length is 63 bytes.” |
Severity | Warning |
Resolution | Retry the operation using an ETag with a length of 63 bytes or less. |
iLO.2.21.EmptyDNSName
DNS name is empty.
Message Format | “Empty DNS name.” |
Severity | Warning |
Resolution | Retry the request with a valid DNS name. |
iLO.2.21.ErrorIntializingESKM
Failed to initialize ESKM.
Message Format | “Failed to initialize ESKM.” |
Severity | Warning |
Resolution | Check if Account Group, Local CA Certificate Name, Login Name and Password are correct and try again. |
iLO.2.21.EventLogCleared
Event log cleared successfully.
Message Format | “Event log cleared successfully.” |
Severity | OK |
Resolution | None. |
iLO.2.21.EventSubscriptionModified
The event subscription was modified successfully.
Message Format | “The event subscription was modified successfully.” |
Severity | OK |
Resolution | None. |
iLO.2.21.EventSubscriptionRemoved
The event subscription was removed successfully.
Message Format | “The event subscription was removed successfully.” |
Severity | OK |
Resolution | None. |
iLO.2.21.ExtendedInfo
Indicates that extended information is available.
Message Format | “See @Message.ExtendedInfo for more information.” |
Severity | OK |
Resolution | See @Message.ExtendedInfo for more information. |
iLO.2.21.FWFlashSuccessTPMOverrideEnabled
A Trusted Module is detected in this system. If you have not performed the proper OS encryption procedures, you will lose access to your data if recovery key is not available. Recommended procedure is to suspend encryption software prior to System ROM or Option ROM firmware flash. TPMOverrideFlag is enabled and firmware flash initiated.
Message Format | “CAUTION: A Trusted Module is detected in this system. Updating the System ROM or Option Card Firmware may have impact to measurements stored in the TM and may have impact to security functionality on the platform which depends on these measurements.” |
Severity | OK |
Resolution | None. |
iLO.2.21.FWFlashSuccessTrustedModuleOverrideEnabled
A Trusted Module (type unspecified) is installed in the system and TPMOverrideFlag is enabled. Firmware flash initiated.
Message Format | “CAUTION: A Trusted Module (type unspecified) has been detected in this system. If you have not performed the proper OS encryption procedures, you will lose access to your data if recovery key is not available. Recommended procedure for Microsoft Windows® BitLocker™ is to "suspend” BitLocker prior to System ROM or Option ROM firmware flash.“ |
Severity | OK |
Resolution | None. |
iLO.2.21.FWFlashTPMOverrideFlagRequired
A Trusted Module is detected in this system. Failure to perform proper OS encryption procedures will result in loss of access to your data if recovery key is not available. Recommended procedure is to suspend encryption software prior to System ROM or Option ROM firmware flash. If you do not have your recovery key or have not suspended encryption software, cancel this firmware upload. Failure to follow these instructions will result in loss of access to your data. To continue with firmware flash TPMOverrideFlag is required.
Message Format | "CAUTION: A Trusted Module is detected in this system. Updating the System ROM or Option Card Firmware may have impact to measurements stored in the TM and may have impact to security functionality on the platform which depends on these measurements.” |
Severity | Warning |
Resolution | Please set the TPMOverrideFlag to true and try again. |
iLO.2.21.FWFlashTrustedModuleOverrideFlagRequired
A Trusted Module (type unspecified) is installed in the system, TPMOverrideFlag is required for firmware flash to proceed.
Message Format | “CAUTION: A Trusted Module (type unspecified) has been detected in this system. Failure to perform proper OS encryption procedures will result in loss of access to your data if recovery key is not available. Recommended procedure for Microsoft Windows® BitLocker™ is to "suspend” BitLocker prior to System ROM or Option ROM firmware flash. If you do not have your recovery key or have not suspended BitLocker, exit this flash: Failure to follow these instructions will result in loss of access to your data.“ |
Severity | Warning |
Resolution | Please set the TPMOverrideFlag to true and try again. |
iLO.2.21.FirmwareFlashAlreadyInProgress
A firmware upgrade operation is already in progress.
Message Format | "A firmware flash operation is already in progress.” |
Severity | Warning |
Resolution | Wait for the current firmware flash to complete, and then retry the operation. |
iLO.2.21.GeneratingCertificate
Generating the X509 Certificate.
Message Format | “X509 Certificate is being generated and the process might take up to 10 minutes.” |
Severity | OK |
Resolution | None. |
iLO.2.21.HardDriveZoneBackupFailure
Backup hard drive zoning configuration to BMC has encountered an error.
Message Format | “Backup hard drive zoning configuration to BMC has encountered an error.” |
Severity | Warning |
Resolution | Retry the operation. If the problem persists, consider resetting the BMC or the entire chassis. |
iLO.2.21.HardDriveZoneFailure
Hard Drive Zoning was in error state.
Message Format | “Hard Drive Zoning was in error state due to %1.” |
Severity | Critical |
Resolution | Retry the operation. If the problem persists, consider resetting the entire chassis. |
iLO.2.21.HashAlgNotSupported
Hash Algorithm not supprted, please enable SHA384 on the host and try.
Message Format | “Hash Algorithm not supprted, please enable SHA384 on the host and try.” |
Severity | Warning |
Resolution | Enable SHA384 on host |
iLO.2.21.ICRUInvalidAddress
ICRU returned invalid address for translation.
Message Format | “ICRU returned invalid address for translation.” |
Severity | Warning |
Resolution | Input valid address for translation. |
iLO.2.21.ICRUNotSupported
ICRU feature or function is not supported on the system.
Message Format | “ICRU feature or function is not supported on the system.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.IPv6ConfigurationError
The specified IPv6 configuration caused an error.
Message Format | “The specified IPv6 configuration was in error due to %1.” |
Severity | Warning |
Resolution | Resolve the indicated error in the configuration data. |
iLO.2.21.ImportCertFailCSRMissing
Failed to import the Certificate because the corresponding CSR is missing.
Message Format | “Failed to import the X509 Certificate because the CSR is missing.” |
Severity | Warning |
Resolution | Retry the Certificate Import after generating the CSR on the same machine. |
iLO.2.21.ImportCertSuccessful
Import Certificate was successful.
Message Format | “Import Certificate was successful.” |
Severity | OK |
Resolution | None. |
iLO.2.21.ImportCertSuccessfuliLOResetinProgress
Import Certificate was successful and the management processor is being reset.
Message Format | “Import Certificate was successful. Management Processor reset is in progress to enable the new certificate.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.ImportCertificateFailed
Failed importing Certificate.
Message Format | “Failed importing the X509 Certificate.” |
Severity | Warning |
Resolution | Retry the operation with proper Certificate information. |
iLO.2.21.ImportSSOParamError
Not a valid parameter.
Message Format | “Invalid Parameter.” |
Severity | Warning |
Resolution | Retry the request with valid parameters. |
iLO.2.21.ImportSSOUriError
Not a valid Uri to import SSO certificate.
Message Format | “Invalid Uri.” |
Severity | Warning |
Resolution | Retry the request with valid URI. |
iLO.2.21.IndicatorLedInvalidStateChange
The request to change the state of the Indicator LED cannot be granted because the current state is either Blinking or is Unknown.
Message Format | “The Indicator LED cannot be changed when its state is Blinking or Unknown.” |
Severity | Warning |
Resolution | Please wait until the server has completed its reserved state. |
iLO.2.21.InstallSetWriteError
The InstallSet write failed.
Message Format | “The InstallSet write of %1 failed.” |
Severity | Warning |
Resolution | Ensure a valid name for the item and that space exists to hold the item. |
iLO.2.21.InterfaceDisabledResetRequired
Disabling one or more interfaces/features will cause certain functionalities to be not available. Please refer to User Guide for details on the implications. Changes will not take effect until the management processor is reset
Message Format | “CAUTION: Disabling one or more interfaces/features will cause certain functionalities to be not available. Please refer to User Guide for details on the implications. Changes will not take effect until the management processor is reset” |
Severity | OK |
Resolution | None. |
iLO.2.21.InternalErrorWithParam
The operation was not successful due to an internal service error (shown), but the service is still operational.
Message Format | “The operation was not successful due to an internal service error (%1), but the service is still operational.” |
Severity | Critical |
Resolution | Retry the operation. If the problem persists, consider resetting the service. |
iLO.2.21.InvalidConfigurationSpecified
The specified configuration is not valid.
Message Format | “The specified configuration is not valid.” |
Severity | Warning |
Resolution | Correct the configuration, and then retry the operation. |
iLO.2.21.InvalidConfigurationSpecifiedForFederation
iLO Federation Management cannot be supported in the current configuration.
Message Format | “iLO Federation Management cannot be supported in the current configuration.” |
Severity | Warning |
Resolution | Review the management processor network settings or Onboard Administrator settings and refer to the User Guide. |
iLO.2.21.InvalidDwellTime
The dwell time specified is not valid.
Message Format | “The dwell time %1 is not valid.” |
Severity | Warning |
Resolution | Adhere to the dwell time supported. |
iLO.2.21.InvalidEngineID
EngineID should be a hexadecimal number starting with 0x (for example, 0x0102030405abcdef). The string length should be an even number, greater than or equal to 6 characters (excluding the “0x”), and less than or equal to 32 characters.
Message Format | “EngineID should be a hexadecimal number starting with 0x (for example, 0x0102030405abcdef). The string length should be an even number, greater than or equal to 6 characters (excluding the "0x”), and less than or equal to 32 characters.“ |
Severity | Warning |
Resolution | Retry the operation using an EngineID within the specified parameters. |
iLO.2.21.InvalidLicenseKey
The license key is not valid.
Message Format | "The license key is not valid.” |
Severity | Warning |
Resolution | Retry the operation using a valid license key. |
iLO.2.21.InvalidNonceLength
The nonce length is not valid.
Message Format | “A valid nonce length must be between %1 to %2 characters” |
Severity | Critical |
Resolution | Retry the operation using a corrected nonce. |
iLO.2.21.InvalidOperationForAutoPowerOnState
The operation was not successful because the current auto power on mode specifies power is to remain off.
Message Format | “The auto power on delay cannot be set because power is configured to remain off.” |
Severity | Warning |
Resolution | Verify that the system auto power on mode is set to turn power on or follow the previous power setting. |
iLO.2.21.InvalidOperationForSystemState
The operation was not successful due to the current power state (for example, attempting to turn the power off when it is already off).
Message Format | “The operation was not successful due to the current power state.” |
Severity | Warning |
Resolution | Verify that the system is in the correct power state, and then retry the operation. |
iLO.2.21.InvalidPassphraseLength
The passphrase length is not valid.
Message Format | “%1 must contain from %2 to %3 characters.” |
Severity | Warning |
Resolution | Correct the passphrase, and then retry the operation. |
iLO.2.21.InvalidPasswordComplexity
The password failed the complexity enforcement.
Message Format | “A valid password must contain three of the following: uppercase, lowercase, numerals, and other.” |
Severity | Critical |
Resolution | Retry the operation using a corrected password. |
iLO.2.21.InvalidPasswordLength
The password length is not valid.
Message Format | “A valid password must contain between %1 to %2 characters.” |
Severity | Critical |
Resolution | Retry the operation using a corrected password. |
iLO.2.21.InvalidSerialNumberLength
The serial number length is not valid.
Message Format | “A valid serial number must be %1 characters of length.” |
Severity | Critical |
Resolution | Adjust the length of the serial number and retry the operation. |
iLO.2.21.InvalidUserDefAlertType
The provided alert type is not supported for this feature.
Message Format | “The provided alert type is not supported for this feature.” |
Severity | OK |
Resolution | The supported alert types are ‘Warning’ and ‘Critical.’ |
iLO.2.21.InvalidUserDefSensorNumber
The provided sensor number is not supported for this feature.
Message Format | “The provided sensor number is not supported for this feature.” |
Severity | OK |
Resolution | Verify that the provided sensor number is a supported sensor. |
iLO.2.21.InvalidUserDefTemperatureThresholdValue
The user defined temperature threshold value for a sensor cannot exceed the hardware defined cautionary temperature threshold.
Message Format | “The user defined temperature threshold value for a sensor cannot exceed the hardware defined cautionary temperature threshold.” |
Severity | OK |
Resolution | Enter a value lower than the cautionary threshold defined for the corresponding sensor. |
iLO.2.21.LicenseKeyDenied
The license key activation was refused. Includes details.
Message Format | “The license activation key cannot be installed. %1” |
Severity | Warning |
Resolution | Address the condition or use a valid license activation key. |
iLO.2.21.LicenseKeyNotSupported
The license key supplied is unsupported on this system. The key may activate a different product or unsupported tier.
Message Format | “The supplied license key is not supported on this system.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.LicenseKeyRequired
A license key is required to use this operation or feature.
Message Format | “A license key is required to use this operation or feature.” |
Severity | Warning |
Resolution | Install a license key to use this feature. |
iLO.2.21.LocationIndicatorActiveInvalidStateChange
The request to change the state of the Indicator LED cannot be granted because the current state is either Blinking or is Unknown.
Message Format | “The Indicator LED cannot be changed when its state is Blinking or Unknown.” |
Severity | Warning |
Resolution | Please wait until the server has completed its reserved state. |
iLO.2.21.LoginAttemptDelayed
The login was not successful, so the service enforces a delay before another login is allowed.
Message Format | “The login was not successful, so the service enforces a delay before another login is allowed.” |
Severity | Warning |
Resolution | Wait for the delay time to expire, and then retry the login. |
iLO.2.21.LoginAttemptDelayedSeconds
The login was not successful, so the service enforces a delay before another login is allowed.
Message Format | “The login was not successful, so the service enforces a %1 second delay before another login is allowed.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.MCTPDiscoveryDisabled
Telemetry service and Workload Performance advisor will be not available with MCTP discovery disabled.
Message Format | “Telemetry service and Workload Performance advisor will be not available with MCTP discovery disabled.” |
Severity | Warning |
Resolution | Enable MCTP discovery for Telemetry service and Workload Performance advisor. |
iLO.2.21.MailNotConfigured
E-mail not configured for two factor authetication to recieve token.
Message Format | “E-mail not configured for two factor authetication to recieve token.” |
Severity | Critical |
Resolution | Configure the E-mail to recieve token. |
iLO.2.21.MaxProviders
The maximum number of providers are already registered.
Message Format | “The maximum number of providers are already registered.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.MaxVirtualMediaConnectionEstablished
No more Virtual Media connections are available, because the maximum number of connections are already established.
Message Format | “No more Virtual Media connections are available, because the maximum number of connections are already established.” |
Severity | Warning |
Resolution | Close an established Virtual Media connection, and then retry creating or opening another connection. |
iLO.2.21.MembistVariablesNotSupported
Membist variables are not supported on the system.
Message Format | “Membist variables are not supported on the system.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.MemoryInterleaveSetError
The memory set specified in InterleaveSets is not supported.
Message Format | “The memory set specified in InterleaveSets is not supported.” |
Severity | Warning |
Resolution | Ensure the memory set specified in InterleaveSets matches one of the memory domain’s InterleavableMemrorySets. |
iLO.2.21.NandMountFailed
NAND mount failed.
Message Format | “NAND mount failed.” |
Severity | Warning |
Resolution | Retry with iLO reset. |
iLO.2.21.NewerVersionRequired
Update does not meet minimum version requirements.
Message Format | “Update does not meet minimum version requirements.” |
Severity | Warning |
Resolution | Use newer version. |
iLO.2.21.NoContent
The requested resource exists but has no content.
Message Format | “The resource exists but has no content.” |
Severity | OK |
Resolution | None |
iLO.2.21.NoEventSubscriptions
There are no event subscriptions registered.
Message Format | “The operation cannot be completed because there are no event subscribers.” |
Severity | Warning |
Resolution |
iLO.2.21.NoPowerMetering
No support for power metering available on platform.
Message Format | “No support for power metering available on platform.” |
Severity | OK |
Resolution | Enable Power Metering on platform if supported. |
iLO.2.21.NoSNMPAlertDestinationsConfigured
No SNMP alert destinations configured or none of the configured destinations are associated with SNMPv1 protocol or SNMPv3 protocol and user.
Message Format | “No SNMP alert destinations configured or none of the configured destinations are associated with SNMPv1 protocol or SNMPv3 protocol and user.” |
Severity | Warning |
Resolution | Configure at least one SNMP alert destination and associate it with SNMPv1 protocol or SNMPv3 protocol and user. |
iLO.2.21.NoSamples
No power history samples are available.
Message Format | “No power history samples are available.” |
Severity | OK |
Resolution | To accumulate power history samples, power on the server, and then wait at least 5 minutes. |
iLO.2.21.NoScriptedVirtualMediaConnectionAvailable
No scripted virtual media connections exist to perform the operation.
Message Format | “No scripted virtual media connections exist to perform the operation.” |
Severity | Warning |
Resolution | Create or open a scripted virtual media connection, and then retry the operation. |
iLO.2.21.NoSpaceforDNSName
No space to store DNS name.
Message Format | “No space to store DNS name.” |
Severity | Warning |
Resolution | Make sure SSO database has enough space to store DNS name. |
iLO.2.21.NoVirtualMediaConnectionAvailable
No Virtual Media connections exist to perform the operation.
Message Format | “No Virtual Media connections exist to perform the operation.” |
Severity | Warning |
Resolution | Create or open a Virtual Media connection, and then retry the operation. |
iLO.2.21.NodeAssignedCrossRegion
Each zone can only manage the node in the same region, cannot manage overlap region.
Message Format | “Each zone can only manage the node for range %1 or range %2, cannot manage overlap region.” |
Severity | Warning |
Resolution | Correct the out of range value, and then retry the operation. |
iLO.2.21.NodeNotPresentInZone
Operation is currently unavailable because there is no node installed in the zone.
Message Format | “Operation is currently unavailable because there is no node installed in the zone.” |
Severity | Warning |
Resolution | Install at least one node in the zone and retry the operation. |
iLO.2.21.NonPLDMUpdateableTargetURI
The Target Url passed is for non PLDM updateable device.
Message Format | “The Target Url %1 posted is for non PLDM updateable device” |
Severity | Warning |
Resolution | Targets URI is for non PLDM updateable device. Provide a valid PLDM updateable Targets URI and resubmit the request. |
iLO.2.21.NotSupportedOnNIC
This property is not supported by the indicated network port.
Message Format | “%1 is not supported on the %2 Network Port.” |
Severity | Warning |
Resolution | Do not specify this property on the indicated network port. |
iLO.2.21.NotValidIPAddrOrDNS
The value for the property is not a valid IPv4/v6 address or DNS name.
Message Format | “The value for property %1 is not a valid IPv4/v6 address or DNS name.” |
Severity | Warning |
Resolution | Correct the IPv4/v6 address or DNS name, and then retry the operation. |
iLO.2.21.NotValidIPAddress
The value for the property is not a valid IP address.
Message Format | “The value %1 is not a valid IP address for %2” |
Severity | Warning |
Resolution | Use a valid IP address. |
iLO.2.21.NotValidSubnetMask
The value for the property is not a valid subnet mask.
Message Format | “The value %1 is not a valid subnet mask for %2” |
Severity | Warning |
Resolution | Use a valid subnet mask. |
iLO.2.21.OperationAvailableAfterSystemPOST
The value for the property can not be set until System BIOS POST completes.
Message Format | “Property %1 will be settable after the System BIOS completes POST.” |
Severity | Warning |
Resolution | Wait to see the change in value until after the System BIOS completes POST. |
iLO.2.21.OperationWillCompleteAfterSystemPOST
The value for the property will be applied after System BIOS POST completes.
Message Format | “The value for property %1 will be changed after the System BIOS completes POST.” |
Severity | OK |
Resolution | Wait to see the change in value until after the System BIOS completes POST. |
iLO.2.21.PowerCapOACntrld
The enclosure Onboard Administrator is currently managing the power cap.
Message Format | “The enclosure Onboard Administrator is currently managing the power cap.” |
Severity | Warning |
Resolution | Use Onboard Administrator to Manage the PowerCap |
iLO.2.21.PowerCapROMCntrld
The System ROM is currently managing the power cap.
Message Format | “The System ROM is currently managing the power cap.” |
Severity | Warning |
Resolution | Enable RESTful API management of the power cap in System ROM |
iLO.2.21.PowerLimitMayNotTakeEffect
One of power limit setpoint may become unreachable due to power limit range is unknown. It’s not recommended configure power limit setpoint when power limit range is unknown.
Message Format | “One of power limit setpoint may become unreachable due to power limit range is unknown. It’s not recommended configure power limit setpoint when power limit range is unknown.” |
Severity | Warning |
Resolution | Please execute calibrate action to get power limit range then reconfigure power limit setpoint. |
iLO.2.21.PowerRegulationNotDisable
Operation is currently unavailable because chassis power regulation is enabled.
Message Format | “Operation is currently unavailable because chassis power regulation is enabled.” |
Severity | Warning |
Resolution | Disable chassis power regulation, and then retry the operation. |
iLO.2.21.PowerSettingAdjustRequired
Indicates that one or more power limit setting were correctly changed, but will not take effect until power regulation enable and power regulator mode switch to user configurable mode.
Message Format | “Indicates that one or more power limit setting were correctly changed, but will not take effect until power regulation enable and power regulator mode switch to user configurable mode.” |
Severity | Warning |
Resolution | Enable power regulation and switch power regulator mode to user configurable mode for the settings to take effect. |
iLO.2.21.PowerValueBadParam
The power cap value is not valid.
Message Format | “The power cap value is not valid.” |
Severity | Warning |
Resolution | Retry the operation using a corrected value. |
iLO.2.21.PowerValueInvalidCalibrationData
The request to set the power cap failed. Invalid power cap calibration data. The Power Cap feature is currently unavailable.
Message Format | “The request to set the power cap failed. Invalid power cap calibration data. The Power Cap feature is currently unavailable” |
Severity | Warning |
Resolution | Restart the server to retrieve calibration data from initial POST. |
iLO.2.21.PowerValueNotOptimal
Power caps set below the specified percentage threshold might become unreachable due to changes in the server. It is recommended to not set a cap for less than this threshold.
Message Format | “Power caps set below the specified percentage threshold might become unreachable due to changes in the server. It is recommended to not set a cap for less than %1.” |
Severity | Warning |
Resolution | Please provide an optimal value in integer considering the power cap range. |
iLO.2.21.PowerValueUnAvailable
Advanced power capping is not currently available due to the system configuration or state.
Message Format | “Advanced power capping is not currently available due to the system configuration or state.” |
Severity | Warning |
Resolution | Change the system configuration or wait for the system to become fully initialized, and then retry the operation. |
iLO.2.21.PowerValueUnSupported
Advanced power capping is not supported on this system.
Message Format | “Advanced power capping is not supported on this system.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.PrimaryESKMServerAccessible
Only the primary ESKM server is accessible.
Message Format | “No redundancy. Only the primary ESKM server is accessible.” |
Severity | OK |
Resolution | None. |
iLO.2.21.PrimarySecondaryAddressesResolveToSameServer
Primary and secondary ESKM server addresses resolve to the same server.
Message Format | “No redundancy. Primary and secondary ESKM server addresses resolve to the same server.” |
Severity | OK |
Resolution | None. |
iLO.2.21.PrimarySecondaryESKMServersAccessible
Both primary and secondary ESKM servers are accessible.
Message Format | “Redundant solution: Both primary and secondary ESKM servers are accessible.” |
Severity | OK |
Resolution | None. |
iLO.2.21.PropertyNotSupported
The property is not supported.
Message Format | “The property %1 is not supported.” |
Severity | Warning |
Resolution | Do not attempt to modify this property. |
iLO.2.21.PropertyNotWritableOrUnknown
The request included a value for a read-only or unknown property.
Message Format | “The property %1 is a read-only property and cannot be assigned a value, or not valid for this resource.” |
Severity | Warning |
Resolution | If the operation did not complete, remove the property from the request body and resubmit the request. |
iLO.2.21.PropertyValueAlreadySet
The value being set for the property is same as existing value.
Message Format | “The new value %1 is same as existing value for the property %2.” |
Severity | OK |
Resolution | None |
iLO.2.21.PropertyValueBadParam
The property value is not valid.
Message Format | “The property value is not valid.” |
Severity | Warning |
Resolution | Retry the operation using a corrected value. |
iLO.2.21.PropertyValueExceedsMaxLength
The value for the property exceeds the maximum length.
Message Format | “The value %1 for the property %2 exceeds the maximum length of %3.” |
Severity | Warning |
Resolution | Correct the value for the property in the request body, and then retry the operation. |
iLO.2.21.PropertyValueIncompatible
The value for the property is the correct type, but this value is incompatible with the current value of another property.
Message Format | “The value %1 for the property %2 is incompatible with the value for property %3.” |
Severity | Warning |
Resolution | Correct the value for the property in the request body, and then retry the operation. |
iLO.2.21.PropertyValueOutOfRange
The value for the property is out of range.
Message Format | “The value %1 for the property %2 is out of range %3.” |
Severity | Warning |
Resolution | Correct the value for the property in the request body, and then retry the operation. |
iLO.2.21.PropertyValueRequired
Indicates that a property was required but not specified.
Message Format | “%1 requires Property %2 to be specified.” |
Severity | Warning |
Resolution | Include the required property in the request body and then retry the operation. |
iLO.2.21.RecoveryInstallSetRequired
A recovery install set is required for this action.
Message Format | “No recovery install set present.” |
Severity | Critical |
Resolution | Create a recovery install set (install set with IsRecovery property set true). |
iLO.2.21.RepairNotSupported
IML event with this severity is not supported to be repaired. IML events with Critical or Warning severities can marked as repaired.
Message Format | “IML event with %1 severity is not supported to be repaired. IML events with Critical or Warning severities can marked as repaired.” |
Severity | Warning |
Resolution | Please do not try to repair IML events with severity other than Critical or Warning. |
iLO.2.21.RequiredPropertyMissing
Indicates that a required property is not specified.
Message Format | “Required Property %1 needs to be specifed.” |
Severity | Warning |
Resolution | Include the required property in the request body and then retry the operation. |
iLO.2.21.ResetInProgress
A management processor reset is in progress.
Message Format | “A management processor reset is in progress.” |
Severity | Warning |
Resolution | Wait for management processor reset to complete, and then retry the operation. |
iLO.2.21.ResetRequired
One or more properties were changed, but these changes will not take effect until the management processor is reset.
Message Format | “One or more properties were changed, but these changes will not take effect until the management processor is reset.” |
Severity | Warning |
Resolution | To enable the changed properties, reset the management processor. |
iLO.2.21.ResourceBeingFlashed
The change to the requested resource failed because the resource is being flashed.
Message Format | “The change to the requested resource failed because the resource is being flashed.” |
Severity | Warning |
Resolution | Retry the operation when the firmware upgrade has completed. |
iLO.2.21.ResourceInUseWithDetail
The change could not be made because the resource was in use or in a transitioning state.
Message Format | “The change to the resource failed because the resource is in use or in transition.” |
Severity | Warning |
Resolution | Retry the request. |
iLO.2.21.ResourceNotReadyRetry
The resource is present but is not ready to perform operations due to an internal condition such as initialization or reset.
Message Format | “The resource is present but is not ready to perform operations. The resource will be ready in %1 seconds.” |
Severity | Warning |
Resolution | Retry the operation when the resource is ready. |
iLO.2.21.ResourceTemporarilyUnavailable
The resource is temporarily unavailable because the firmware is being flashed.
Message Format | “The resource is temporarily unavailable because the firmware is being flashed.” |
Severity | Warning |
Resolution | Retry the operation when the firmware upgrade has completed. |
iLO.2.21.SMBIOSRecordNotFound
The SMBIOS record type is not found or is not supported on the system.
Message Format | “The SMBIOS record type %1 is not found or is not supported on the system.” |
Severity | Warning |
Resolution | Reset the system to update the SMBIOS records. If the problem persists then the SMBIOS record type is not supported. |
iLO.2.21.SNMPAlertDisabled
The operation could not be completed because SNMP alerts are disabled.
Message Format | “The operation could not be completed because SNMP alerts are disabled.” |
Severity | Warning |
Resolution | Enable SNMP alerts and retry the operation. |
iLO.2.21.SNMPDisabled
Modifying SNMP properties is not possible with SNMP disabled.
Message Format | “Modifying SNMP properties is not possible with SNMP disabled.” |
Severity | Warning |
Resolution | Enable SNMP, and then modify the SNMP properties. |
iLO.2.21.SNMPTestAlertFailed
The SNMP Test Alert did not send successfully.
Message Format | “The SNMP Test Alert did not send successfully.” |
Severity | Warning |
Resolution | Verify the test alert content and retry. |
iLO.2.21.SNMPv1Disabled
Modifying SNMP v1 properties is not possible with SNMP v1 protocol disabled.
Message Format | “Modifying SNMP v1 properties is not possible with SNMP v1 protocol disabled.” |
Severity | Warning |
Resolution | Enable SNMP v1, and then modify the SNMP v1 properties. |
iLO.2.21.SNMPv3Disabled
Modifying SNMP v3 properties is not possible with SNMP v3 protocol disabled.
Message Format | “Modifying SNMP v3 properties is not possible with SNMP v3 protocol disabled.” |
Severity | Warning |
Resolution | Enable SNMP v3, and then modify the SNMP v3 properties. |
iLO.2.21.SNTPConfigurationManagedByDHCPAndIsReadOnly
SNTP configuration is currently managed by DHCP and is therefore read-only.
Message Format | “%1 cannot be changed while DHCP is configured to provide SNTP settings.” |
Severity | Warning |
Resolution | Disable SNTP configuration options in both DHCPv4 and DHCPv6 (see /Managers/n/NICs), and then reconfigure SNTP as desired with static settings. |
iLO.2.21.SSOCertficateEmpty
SSO Certificate is Empty.
Message Format | “Empty SSO Certificate.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.SSOCertificateReadError
SSO Certificate Read Error.
Message Format | “Error reading SSO certificate.” |
Severity | Warning |
Resolution | Retry the request with valid SSO certificate. |
iLO.2.21.SSONoSpaceError
No space to store SSO certificate.
Message Format | “No space to store SSO certificate.” |
Severity | Warning |
Resolution | Make sure SSO database has enough space to store SSO certificate. |
iLO.2.21.SSORecordNotFound
SSO Record Not Found.
Message Format | “SSO Record Not Found.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.SamplesNotCaptured
Samples are not captured for %1 duration.
Message Format | “Samples for metrics are not captured for %1 duration.” |
Severity | OK |
Resolution | Wait for the current duration to complete, and then retry. |
iLO.2.21.SecondaryESKMServerAccessible
Only the secondary ESKM server is accessible.
Message Format | “No redundancy. Only the secondary ESKM server is accessible.” |
Severity | OK |
Resolution | None. |
iLO.2.21.ServerConfigLockStatusUnknown
The current status of Server Configuration Lock is unknown.
Message Format | “The current status of Server Configuration Lock is unknown.” |
Severity | Warning |
Resolution | Ensure if the BIOS firmware supports Server Configuration Lock. If supported, reboot the server and retry the operation |
iLO.2.21.ServerConfigurationLockEnabled
Server Configuration Lock is enabled.
Message Format | “Server Configuration Lock is enabled.” |
Severity | Warning |
Resolution | Disable Server Configuration Lock to initiate secure erase of the system |
iLO.2.21.SimpleUpdateInvalidImageOrCredentials
The ESXio Image or Username and Password to access the ESXio image URI is not valid.
Message Format | “The ESXio image or username and password credentials provided to access the ESXio Image URI : %1 posted in %2 is not valid.” |
Severity | Warning |
Resolution | ESXio image URI/Username/Password is incorrect. Please provide valid details and resubmit the request. |
iLO.2.21.SimpleUpdateInvalidImageURI
The Url passed for the simple update for firmware image download is not valid.
Message Format | “The firmware Image Url %1 posted in %2 is not valid.” |
Severity | Warning |
Resolution | FirmwareImage URL is incorrect. Provide a valid firmware Image URL and resubmit the request. |
iLO.2.21.SimpleUpdateInvalidTargetsURI
The Targets URI passed for the simple update for firmware image download is not valid.
Message Format | “The Targets URI %1 posted in %2 is not valid.” |
Severity | Warning |
Resolution | Targets URI is incorrect. Provide a valid Targets URI and resubmit the request. |
iLO.2.21.SmartNICDeviceError
SmartNIC DPU operation failed due to SmartNIC device error.
Message Format | “SmartNIC DPU operation failed due to SmartNIC device error %1.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.SmartNICNotPresent
SmartNIC DPU not present in iLO.
Message Format | “SmartNIC DPU URI %1 posted in %2 is not present.” |
Severity | Warning |
Resolution | System can either be managed by HPE OneView or Compute Ops Management. |
iLO.2.21.SuccessFeedback
The operation completed successfully.
Message Format | “The operation completed successfully.” |
Severity | OK |
Resolution | None |
iLO.2.21.SyslogFeatureDisabled
Remote Syslog feature is disabled.
Message Format | “Remote syslog feature is disabled.” |
Severity | Warning |
Resolution | Enable remote syslog feature to send test syslog message. |
iLO.2.21.SystemPowerOffRequired
To perform this operation, power off the system. AutoPowerOn must be set to achieve a power restore.
Message Format | “To perform this operation, power off the system.” |
Severity | OK |
Resolution | To perform this operation, power off the system. |
iLO.2.21.SystemPowerStateChangeFailed
System power state change failed (for example, attempting to turn the system power On/Off failed)
Message Format | “System power state change failed” |
Severity | Warning |
Resolution | Retry the request. |
iLO.2.21.SystemResetRequired
The system properties were correctly changed, but will not take effect until the system is reset.
Message Format | “One or more properties were changed and will not take effect until system is reset.” |
Severity | Warning |
Resolution | Reset system for the settings to take effect. |
iLO.2.21.TargetsLimitExceeded
The Target Url count exceeded the limit.
Message Format | “The Target Url count exceeded the limit.” |
Severity | Warning |
Resolution | Provide Targets URI’s within maximum allowable range and resubmit the request. |
iLO.2.21.TokenRequired
Proper ‘X-HPRESTFULAPI-AuthToken’ authorization token not provided.
Message Format | “Proper ‘X-HPRESTFULAPI-AuthToken’ authorization token not provided.” |
Severity | Critical |
Resolution | Create proper ‘X-HPRESTFULAPI-AuthToken’ authorization token. Send token in using the proper HTTP header. |
iLO.2.21.UnableModifyRights
Unable to modify user rights.
Message Format | “Unable to modify user rights.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.UnableToModifyAfterVirtualMediaInsert
The value for the property cannot be changed after virtual media image is inserted.
Message Format | “The value for property %1 cannot be changed after virtual media image is inserted.” |
Severity | Warning |
Resolution | Retry the operation during virtual media image insertion. |
iLO.2.21.UnableToModifyDueToMissingComponent
The value for the property cannot be changed because a related hardware component is not installed.
Message Format | “The value for property %1 cannot be changed because a related hardware component is not installed.” |
Severity | Warning |
Resolution | Install the hardware component and retry the operation. |
iLO.2.21.UnableToModifyDuringSystemPOST
The value for the property cannot be changed while the computer system BIOS is in POST.
Message Format | “The value for property %1 cannot be changed while the computer system BIOS is in POST.” |
Severity | Warning |
Resolution | After the computer system is either fully booted or powered off, retry the operation. |
iLO.2.21.UnableToModifyWhileKVMIPConnected
The value for the property cannot be changed while a KVMIP connection is in progress.
Message Format | “The value for property %1 cannot be changed while a KVMIP connection is in progress.” |
Severity | Warning |
Resolution | Retry the operation after disconnecting all KVMIP connections. |
iLO.2.21.UnauthorizedLoginAttempt
The login was not successful, because the supplied credentials could not be authorized.
Message Format | “The login was not successful, because the supplied credentials could not be authorized.” |
Severity | Warning |
Resolution | Log in with authorized user name and password credentials. |
iLO.2.21.UnsupportedCipherAlgo
Incompatible Cipher Algorithm in FIPS or CNSA Mode.
Message Format | “Incompatible Cipher Algorithm %1 in %2 Mode.” |
Severity | Warning |
Resolution | Select compatible Cipher Algorithm. |
iLO.2.21.UnsupportedOperation
This operation is not supported by RIS for the current system.
Message Format | “This operation is not supported by RIS for the current system.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.UnsupportedOperationACEEnabled
This operation is not supported when certificate enrollment service is enabled.
Message Format | “This operation is not supported when certificate enrollment service is enabled.” |
Severity | OK |
Resolution | Disable certificate enrollment Service to initiate import, delete or generate CSR of SSL certificate. |
iLO.2.21.UnsupportedOperationInChassisVersion
This operation is not supported by the current version of the XL Chassis firmware.
Message Format | “This operation is not supported by the current version of the XL Chassis firmware.” |
Severity | Warning |
Resolution | Please update the XL Chassis firmware to latest version. |
iLO.2.21.UnsupportedOperationInLegacyBootMode
This operation is not supported when the system Boot Mode is set to Legacy BIOS.
Message Format | “ This operation is not supported when the system Boot Mode is set to Legacy BIOS.” |
Severity | Warning |
Resolution | Change the Boot Mode to UEFI and retry the operation. |
iLO.2.21.UnsupportedOperationInSystemBIOS
This operation is not supported by the current version of the system BIOS.
Message Format | “This operation is not supported by the current version of the system BIOS.” |
Severity | Warning |
Resolution | None. |
iLO.2.21.UnsupportedSecurityState
The operation was not successful due to the current security state of the management processor.
Message Format | “The operation was not successful due to the current security state of the management processor.” |
Severity | Warning |
Resolution | Retry the operation with the correct security state. |
iLO.2.21.UpdateBadParameter
The update failed because a bad parameter was supplied.
Message Format | “The update failed because a bad parameter was supplied.” |
Severity | Critical |
Resolution | Supply correct parameters to the component and retry the update. |
iLO.2.21.UpdateCancelled
The update was canceled by the update process.
Message Format | “The update was canceled by the update process.” |
Severity | Critical |
Resolution | Retry the update. |
iLO.2.21.UpdateDependencyFailure
The update did not complete because the component failed a dependency check.
Message Format | “The update did not complete because the component failed a dependency check.” |
Severity | Critical |
Resolution | Install any dependent components first and then retry this update. |
iLO.2.21.UpdateFailed
The update failed with a component specific error (%1).
Message Format | “The update failed with a component specific error (%1).” |
Severity | Critical |
Resolution | Retry the update after remedying the component error. |
iLO.2.21.UpdateInPOST
System must not be booted past POST in order to perform this update
Message Format | “System must not be booted past POST in order to perform this update” |
Severity | Critical |
Resolution | Boot to UEFI and retry the update. |
iLO.2.21.UpdateInterrupted
The update was interrupted.
Message Format | “The update was interrupted.” |
Severity | Critical |
Resolution | Retry the update. |
iLO.2.21.UpdateInvalidFile
The update operation failed because the file is not valid.
Message Format | “The update operation failed because the file is not valid.” |
Severity | Critical |
Resolution | Remove and re-add the component to the repository and try the operation again. |
iLO.2.21.UpdateInvalidOS
The update did not occur because the running OS is not valid.
Message Format | “The update did not occur because the running OS is not valid.” |
Severity | Critical |
Resolution | Retry the update while running the correct OS. |
iLO.2.21.UpdateNotApplicable
The task was not completed because the component was not applicable to this system.
Message Format | “The task was not completed because the component was not applicable to this system.” |
Severity | Critical |
Resolution | None. |
iLO.2.21.UpdateRepositoryUnavailable
The update operation failed because the component repository is unavailable.
Message Format | “The update operation failed because the component repository is unavailable.” |
Severity | Critical |
Resolution | None. |
iLO.2.21.UpdateSimpleStatus
This is to update the esxio image flashing status into SmartNIC DPU systems.
Message Format | “TaskState is %1 and TaskStatus is %2 and Message is %3 and Percent Complete is %4” |
Severity | Warning |
Resolution | None |
iLO.2.21.UpdateTaskQueueFull
The Invoke action was not successful because the update task queue is full.
Message Format | “The Invoke action was not successful because the update task queue is full.” |
Severity | Critical |
Resolution | Remove completed tasks from the update task queue to retry the operation. |
iLO.2.21.UpdateTaskQueueWriteError
The UpdateTaskQueue write failed.
Message Format | “The UpdateTaskQueue write of %1 failed.” |
Severity | Warning |
Resolution | Ensure a valid name for the item and that space exists to hold the item. |
iLO.2.21.UpdateTemporarilyUnavailable
The system is temporarily unable to perform this update
Message Format | “The system is temporarily unable to perform this update” |
Severity | Critical |
Resolution | Retry the update, ensuring that power state is stable. |
iLO.2.21.UpdateWithPowerOff
System power must be off to perform this update
Message Format | “System power must be off to perform this update” |
Severity | Critical |
Resolution | Power system on and retry the update. |
iLO.2.21.UpdateWithPowerOn
System power must be on to perform this update
Message Format | “System power must be on to perform this update” |
Severity | Critical |
Resolution | Power system on and retry the update. |
iLO.2.21.UserAlreadyExist
The user or login user name already exists.
Message Format | “The user or login user name already exists.” |
Severity | Warning |
Resolution | Try a different user or login user name. |
iLO.2.21.UserNameAlreadyExists
Duplicate SNMPv3 User.
Message Format | “The username %1 already exists in the list” |
Severity | Warning |
Resolution | Enter a different name and try again. |
iLO.2.21.VirtualMediaIsDisabled
Virtual Media has been disabled.
Message Format | “Virtual Media has been disabled.” |
Severity | Warning |
Resolution | Enable Virtual Media to perform this operation. |
iLO.2.21.ZonePowerLimitExceeded
The sum of zone power limit cannot be more than chassis power limit.
Message Format | “The value %1 for the sum of %2 cannot be more than chassis power limit %3.” |
Severity | Warning |
Resolution | Correct the value avoid the sum of power limit exceeds chassis power limit, and then retry the operation. |
iLO.2.21.iLOResetAndSystemRebootRequired
Indicates that one or more properties were correctly changed, but will not take effect until device is reset and system is rebooted.
Message Format | “One or more properties were changed and will not take effect until the device is reset and system is rebooted” |
Severity | Warning |
Resolution | Reset the management processor and reboot the server. |
iLO.2.21.iLOSubnetConflict
The subnet being configured has conflicts.
Message Format | “The subnet being configured for %1 conflicts with %2.” |
Severity | Warning |
Resolution | Configure this interface with a different IP Address or Subnet Mask. |
iLO.2.21.iLOVirtualNICDisabled
The Virtual NIC is disabled.
Message Format | “The Virtual NIC is disabled.” |
Severity | Warning |
Resolution | Enable iLO Virtual NIC to perform this operation. |
iLOeRS.1.1.AuthenticationError
Authentication error.
Message Format | “Authentication error.” |
Severity | Critical |
Resolution | Please unregister and re-register the device. |
iLOeRS.1.1.CannotConnectToProxyServer
Unable to connect to the proxy server.
Message Format | “Unable to connect to the proxy server.” |
Severity | Warning |
Resolution | Please verify proxy settings and connectivity. |
iLOeRS.1.1.CannotConnectToRemoteHost
Can not connect to remote host. Transmission to the HPE Insight Remote Support receiver was unsuccessful.
Message Format | “Can not connect to remote host.” |
Severity | Critical |
Resolution | Please check connectivity between Management Processor and the Insight Remote Support receiver and retry. |
iLOeRS.1.1.CannotEstablishSSLConnection
Protocol error occurred while communicating with the HPE Insight Remote Support receiver.
Message Format | “Protocol error occurred while communicating with the HPE Insight Remote Support receiver.” |
Severity | Critical |
Resolution | Please retry. |
iLOeRS.1.1.ChangeOrResetHPEPassportPassword
The HPE Passport password must be changed or reset.
Message Format | “The HPE Passport password must be changed or reset.” |
Severity | Critical |
Resolution | Please attempt to register again after correcting the HPE Passport problem. |
iLOeRS.1.1.ClientReceiveError
Client Receive Error. Transmission to the HPE Insight Remote Support receiver was unsuccessful.
Message Format | “Client Receive Error.” |
Severity | Critical |
Resolution | Please check connectivity between Management Processor and the Insight Remote Support receiver and retry. |
iLOeRS.1.1.ClientReceiveTimeout
Client Receive Timeout. Transmission to the HPE Insight Remote Support receiver was unsuccessful.
Message Format | “Client Receive Timeout.” |
Severity | Warning |
Resolution | Please check connectivity between Management Processor and the Insight Remote Support receiver. |
iLOeRS.1.1.ClientTransmitTimeout
Client Transmit Timeout. Transmission to the HPE Insight Remote Support receiver was unsuccessful.
Message Format | “Client Transmit Timeout.” |
Severity | Warning |
Resolution | Please check connectivity between Management Processor and the Insight Remote Support receiver. |
iLOeRS.1.1.ConnectBIOerror
Connect BIO error. Transmission to the HPE Insight Remote Support receiver was unsuccessful.
Message Format | “Connect BIO error.” |
Severity | Warning |
Resolution | Please check connectivity between Management Processor and the Insight Remote Support receiver and retry. |
iLOeRS.1.1.CorruptDeviceIdentifiers
Corrupt device identifiers.
Message Format | “Corrupt device identifiers.” |
Severity | Critical |
Resolution | Please unregister and re-register the device. |
iLOeRS.1.1.CorruptGDID
The GDID was found to be corrupted.
Message Format | “Corrupt GDID.” |
Severity | Critical |
Resolution | Please unregister and re-register the device. |
iLOeRS.1.1.CorruptGUID
The GUID is found to be corrupted.
Message Format | “Corrupt GUID.” |
Severity | Critical |
Resolution | Please retry your last step. If error persists and device is currently registered, unregister and re-register device. |
iLOeRS.1.1.CorruptRegistrationInformation
The registration information was found to be corrupted.
Message Format | “Corrupt registration information.” |
Severity | Critical |
Resolution | Please unregister and re-register the device. |
iLOeRS.1.1.CorruptRegistrationToken
The registration token was found to be corrupted.
Message Format | “Corrupt registration token.” |
Severity | Critical |
Resolution | Please unregister and re-register the device. |
iLOeRS.1.1.DataPackageValidationFailed
Data Package validation failed.
Message Format | “Data Package validation failed.” |
Severity | Critical |
Resolution | Please retry your last step. If error persists and device is currently registered, unregister and re-register device. |
iLOeRS.1.1.DestinationURLParseError
Destination URL Parse Error.
Message Format | “Destination URL Parse Error.” |
Severity | Warning |
Resolution | None. |
iLOeRS.1.1.DeviceAlreadyRegistered
Device is already registered.
Message Format | “Device is already registered” |
Severity | Warning |
Resolution | Please delete the device from Insight Remote Support user interface and retry registration. |
iLOeRS.1.1.DeviceDeleted
This device has been previously deleted from the Insight Remote Support user interface.
Message Format | “This device has been previously deleted from the Insight Remote Support user interface.” |
Severity | Critical |
Resolution | Please unregister and re-register device. |
iLOeRS.1.1.DeviceIsNotRegistered
Device is not registered. Remote Support registration has been disabled locally on this device. No service events or data collections will be sent until this device has been re-registered.
Message Format | “Device is not registered.” |
Severity | Warning |
Resolution | Please register the device. |
iLOeRS.1.1.DeviceUnregistrationFailed
Unregistration request was not processed successfully by the HPE Remote Support receiver. Remote Support has been disabled locally. No service events or data collections will be sent until this device has been re-registered.
Message Format | “Unregistration request was not processed successfully by the HPE Remote Support receiver.” |
Severity | Critical |
Resolution | Please Register the Device. |
iLOeRS.1.1.ERSIsDisabled
Embedded Remote Support is disabled.
Message Format | “Embedded Remote Support is disabled.” |
Severity | Critical |
Resolution | Please retry registration. |
iLOeRS.1.1.ErrorReadingERSConfiguration
Error reading Embedded Remote Support configuration.
Message Format | “Error reading Embedded Remote Support configuration.” |
Severity | Warning |
Resolution | None. |
iLOeRS.1.1.ErrorRetrievingRegToken
Error retrieving registration token.
Message Format | “Error retrieving registration token.” |
Severity | Warning |
Resolution | None. |
iLOeRS.1.1.ExpiredHPEPassportCredentials
THe HPE Passport credentials expired.
Message Format | “The HPE Passport credentials expired.” |
Severity | Critical |
Resolution | Please attempt to register again after correcting the HPE Passport problem. |
iLOeRS.1.1.ExpiredRegistrationToken
The registration token was found to be expired.
Message Format | “Expired registration token.” |
Severity | Critical |
Resolution | Please unregister and re-register the device. |
iLOeRS.1.1.GeneralReceiverError
General Receiver Error. HPE Remote Support receiver is temporarily unavailable.
Message Format | “General Receiver Error.” |
Severity | Warning |
Resolution | Please retry later. |
iLOeRS.1.1.GenericTransmitError
Generic Transmit Error. Transmission to the HPE Insight Remote Support receiver was unsuccessful.
Message Format | “Generic Transmit Error.” |
Severity | Critical |
Resolution | Please check connectivity between Management Processor and the Insight Remote Support receiver. |
iLOeRS.1.1.HPEPassportAccountIsLockedOut
HPE Passport account is locked out.
Message Format | “HPE Passport account is locked out.” |
Severity | Warning |
Resolution | Please reset your password and retry registration. |
iLOeRS.1.1.HPEPassportAccountLockedOut
The HPE Passport account is locked out.
Message Format | “HPE Passport account locked out.” |
Severity | Critical |
Resolution | Please attempt to register again after correcting the HPE Passport problem. |
iLOeRS.1.1.HPEPassportPasswordHasExpired
HPE Passport Password has expired.
Message Format | “HPE Passport Password has expired.” |
Severity | Critical |
Resolution | Please update your password and retry registration. |
iLOeRS.1.1.HPEPassportPasswordIsRequired
HPE Passport Password is required.
Message Format | “HPE Passport Password is required.” |
Severity | Warning |
Resolution | Please retry registration. |
iLOeRS.1.1.HPEPassportSecurityQandAIsNotCompliant
HPE Passport Security Q and A is not compliant.
Message Format | “HPE Passport Security Q and A is not compliant.” |
Severity | Warning |
Resolution | Please update your HPE Passport security Q and A and retry registration. |
iLOeRS.1.1.HPEPassportSystemFailureOccurred
HPE Passport System failure occurred. A problem has been detected in the HPE Passport system.
Message Format | “HPE Passport System failure occurred.” |
Severity | Critical |
Resolution | Please retry later. |
iLOeRS.1.1.HPEPassportUserHasBeenAddedToaGroup
HPE Passport user has been added to a group.
Message Format | “HPE Passport user has been added to a group.” |
Severity | Warning |
Resolution | Please reset your password and retry registration. |
iLOeRS.1.1.HPEPassportUserIdentityElementsMissing
HPE Passport user identity elements missing.
Message Format | “HPE Passport user identity elements missing.” |
Severity | Warning |
Resolution | Please update your HPE Passport profile and retry registration. |
iLOeRS.1.1.HttpServerProtocolError
HTTP Server Protocol error occurred while communicating with the HPE Insight Remote Support receiver.
Message Format | “HTTP Server Protocol error occurred while communicating with the HPE Insight Remote Support receiver.” |
Severity | Critical |
Resolution | Please retry. |
iLOeRS.1.1.IncorrectHPEPassportPassword
HPE Passport Password is incorrect.
Message Format | “HPE Passport Password is incorrect.” |
Severity | Warning |
Resolution | Please retry registration using the correct password. |
iLOeRS.1.1.InsufficientDeviceIdentifierInformation
Insufficient device identifier information.
Message Format | “Insufficient device identifier information.” |
Severity | Critical |
Resolution | Please unregister and re-register the device. |
iLOeRS.1.1.InsufficientRegistrationData
Insufficient registration data.
Message Format | “Insufficient registration data.” |
Severity | Warning |
Resolution | Please retry registration. |
iLOeRS.1.1.InvalidCommandForConnectModel
Invalid Command For Connect Model.
Message Format | “Invalid Command For Connect Model.” |
Severity | Warning |
Resolution | None. |
iLOeRS.1.1.InvalidConfigurationForConnectModel
Configuration not supported for current connect model.
Message Format | “Configuration not supported for current connect model.” |
Severity | OK |
Resolution | None. |
iLOeRS.1.1.InvalidConnectFileDescriptor
Invalid Connect File Descriptor. Transmission to the HPE Insight Remote Support receiver was unsuccessful.
Message Format | “Invalid Connect File Descriptor.” |
Severity | Warning |
Resolution | Please retry. |
iLOeRS.1.1.InvalidDeviceIdentifierInformation
Invalid device identifier information.
Message Format | “Invalid device identifier information.” |
Severity | Critical |
Resolution | Please unregister and re-register the device. |
iLOeRS.1.1.InvalidFileDescriptor
Invalid File Descriptor. Transmission to the HPE Insight Remote Support receiver was unsuccessful.
Message Format | “Invalid File Descriptor.” |
Severity | Warning |
Resolution | Please check connectivity between Management Processor and the Insight Remote Support receiver and retry. |
iLOeRS.1.1.InvalidHPEPassportCredentials
Invalid HPE Passport credentials was provided.
Message Format | “Invalid HPE Passport credentials.” |
Severity | Warning |
Resolution | Please provide valid HPE Passport credentials. |
iLOeRS.1.1.InvalidHPEPassportUserID
HPE Passport User ID is invalid.
Message Format | “HPE Passport User ID is invalid.” |
Severity | Warning |
Resolution | Please retry registration with a valid user ID. |
iLOeRS.1.1.InvalidMessageId
Invalid Message Id.
Message Format | “Invalid Message Id.” |
Severity | Warning |
Resolution | None. |
iLOeRS.1.1.InvalidNumberOfDaysToReport
Invalid Number of Days to Report.
Message Format | “Invalid Number of Days to Report.” |
Severity | Warning |
Resolution | None. |
iLOeRS.1.1.InvalidProxyCredentials
Authentication with proxy server failed.
Message Format | “Authentication with proxy server failed.” |
Severity | Warning |
Resolution | Please provide proper credentials. |
iLOeRS.1.1.InvalidProxySettings
Invalid Proxy Settings.
Message Format | “Invalid Proxy Settings.” |
Severity | Warning |
Resolution | Please verify proxy settings. |
iLOeRS.1.1.InvalidReceiveBuffer
Invalid Receive Buffer. Transmission to the HPE Insight Remote Support receiver was unsuccessful.
Message Format | “Invalid Receive Buffer.” |
Severity | Warning |
Resolution | Please check connectivity between Management Processor and the Insight Remote Support receiver and retry. |
iLOeRS.1.1.InvalidSessiontoken
The session token is invalid.
Message Format | “The session token is invalid.” |
Severity | Critical |
Resolution | Please retry registration. |
iLOeRS.1.1.MissingAttachments
Missing Attachments.
Message Format | “Missing Attachments.” |
Severity | Critical |
Resolution | Please retry your last step. If error persists and device is currently registered, unregister and re-register device. |
iLOeRS.1.1.MissingDataPackage
The data package is missing.
Message Format | “Missing data package.” |
Severity | Critical |
Resolution | Please retry your last step. If error persists and device is currently registered, unregister and re-register device. |
iLOeRS.1.1.MissingDeviceIdentifiers
Missing device identifiers.
Message Format | “Missing device identifiers.” |
Severity | Critical |
Resolution | Please unregister and re-register the device. |
iLOeRS.1.1.MissingGDID
The GDID was found to be missing.
Message Format | “Missing GDID.” |
Severity | Critical |
Resolution | Please unregister and re-register the device. |
iLOeRS.1.1.MissingGUID
The GUID is missing.
Message Format | “Missing GUID.” |
Severity | Critical |
Resolution | Please retry your last step. If error persists and device is currently registered, unregister and re-register device. |
iLOeRS.1.1.MissingRegistrationInformation
The registration information was found to be missing.
Message Format | “Missing registration information.” |
Severity | Critical |
Resolution | Please unregister and re-register the device. |
iLOeRS.1.1.MissingRegistrationToken
The registration token was found to be missing.
Message Format | “Missing registration token.” |
Severity | Critical |
Resolution | Please unregister and re-register the device. |
iLOeRS.1.1.MissingSOAPHeader
Missing SOAP header.
Message Format | “Missing SOAP header.” |
Severity | Critical |
Resolution | Please retry your last step. If error persists and device is currently registered, unregister and re-register device. |
iLOeRS.1.1.NoActiveHealthFilestoReport
No Active Health Files to Report.
Message Format | “No Active Health Files to Report.” |
Severity | Ok |
Resolution | None. |
iLOeRS.1.1.NoServerCertificate
Certificate error occurred while communicating with the HPE Insight Remote Support receiver.
Message Format | “Certificate error occurred while communicating with the HPE Insight Remote Support receiver.” |
Severity | Critical |
Resolution | Please retry. |
iLOeRS.1.1.ReceiveBIOError
Receive BIO Error. Transmission to the HPE Insight Remote Support receiver was unsuccessful.
Message Format | “Receive BIO Error.” |
Severity | Warning |
Resolution | Please check connectivity between Management Processor and the Insight Remote Support receiver and retry. |
iLOeRS.1.1.RegistrationRequestCouldNotBeQueued
Registration request could not be queued. HPE Remote Support receiver temporarily unavailable.
Message Format | “Registration request could not be queued.” |
Severity | Warning |
Resolution | Please retry later. |
iLOeRS.1.1.SSLBioError
SSL Bio error.
Message Format | “SSL Bio error.” |
Severity | Warning |
Resolution | None. |
iLOeRS.1.1.ServiceUnavailableTemporarily
HPE Remote Support receiver is temporarily unavailable.
Message Format | “HPE Remote Support receiver temporarily unavailable.” |
Severity | Warning |
Resolution | Please retry later. |
iLOeRS.1.1.StaleDeviceIdentifiers
Stale device identifiers.
Message Format | “Stale device identifiers.” |
Severity | Critical |
Resolution | Please unregister and re-register the device. |
iLOeRS.1.1.TooManyAttachments
Too Many Attachments.
Message Format | “Too Many Attachments.” |
Severity | Critical |
Resolution | Please retry your last step. If error persists and device is currently registered, unregister and re-register device. |
iLOeRS.1.1.TooManyPendingRequests
Too Many Pending Requests.
Message Format | “Too Many Pending Requests.” |
Severity | Warning |
Resolution | None. |
iLOeRS.1.1.TransactionTypeError
Transaction type error.
Message Format | “Transaction type error.” |
Severity | Warning |
Resolution | None. |
iLOeRS.1.1.TransmitBufferTooShort
Transmit Buffer Too Short. Transmission to the HPE Insight Remote Support receiver was unsuccessful.
Message Format | “Transmit Buffer Too Short.” |
Severity | Warning |
Resolution | Please check connectivity between Management Processor and the Insight Remote Support receiver and retry. |
iLOeRS.1.1.UnknownDevice
Unknown device.
Message Format | “Unknown device.” |
Severity | Critical |
Resolution | Please unregister and re-register the device. |
iLOeRS.1.1.UnmatchGDIDAndDeviceIdentifiers
GDID and device identifiers do not match.
Message Format | “GDID and device identifiers do not match.” |
Severity | Warning |
Resolution | If error persists and device is not currently registered, unregister and re-register device. |
iLOeRS.1.1.UserHasReachedHalfTheMaximumAllowedLoginAuthenticationFailures
User has reached half the maximum allowed login authentication failures.
Message Format | “User has reached half the maximum allowed login authentication failures.” |
Severity | Critical |
Resolution | Please verify your username and password are correct and retry registration. |
iLOeRS.1.1.UserIDIsRequiredField
User ID is a required field.
Message Format | “User ID is a required field.” |
Severity | Warning |
Resolution | Please retry registration. |
iLOeRS.1.1.UserMustEnterAnHPEPassportSecurityQandAandChangePassword
User must enter an HPE Passport security Q and A and change password.
Message Format | “User must enter an HPE Passport security Q and A and change password.” |
Severity | Warning |
Resolution | Please update your security Q and A, update your password and retry registration. |
iLOeRS.1.1.UserMustHaveAnActiveAuthenticatedSession
User must have an active authenticated session.
Message Format | “User must have an active authenticated session.” |
Severity | Critical |
Resolution | Please retry registration. |
iLOeRS.1.1.XMLNULLPropertyDetected
XML NULL Property Detected.
Message Format | “XML NULL Property Detected.” |
Severity | OK |
Resolution | None. |
iLOeRS.1.1.XMLNoPrintableCharDetected
XML No Printable Char Detected.
Message Format | “XML No Printable Char Detected.” |
Severity | OK |
Resolution | None. |
iLOeRS.1.1.XMLParseError
XML Parse Error.
Message Format | “XML Parse Error.” |
Severity | Warning |
Resolution | None. |
iLOeRS.1.1.XMLParserAllocationError
XML Parser Allocation Error.
Message Format | “XML Parser Allocation Error.” |
Severity | Warning |
Resolution | None. |
iLOResourceEvents.1.3.AdapterConfigurationChange
The specified adapter has had a configuration change.
Message Format | “The adapter in slot %1 has had a configuration change.” |
Severity | OK |
Resolution | None |
iLOResourceEvents.1.3.AggregateHealthStatusChange
There has been a change in one or more subsytems aggregate health statuses.
Message Format | “AggregateServerHealth is %1, BiosOrHardwareHealth is %2, FanRedundancy is %3, Fans status is %4, LiquidCoolingRedundancy is %5, LiquidCooling status is %6, Memory status is %7, Network status is %8, PowerSupplies status is %9, PowerSuppliesMismatch state is %10, PowerSupplyRedundancy is %11, Processors status is %12, SmartStorageBattery status is %13, Storage status is %14 and Temperatures status is %15.” |
Severity | OK |
Resolution | Update the subsystem status accordingly. |
iLOResourceEvents.1.3.AutoShutdownCancelled
Management processor cancelled previously initiated automatic operating system shutdown.
Message Format | “Management processor cancelled previously initiated automatic operating system shutdown. Cause: %1.” |
Severity | OK |
Resolution | Check shutdown cause and the Integrated Management Log (IML) for additional information. |
iLOResourceEvents.1.3.AutoShutdownInitiated
Management processor initiated an automatic operating system shutdown.
Message Format | “Management processor initiated an automatic operating system shutdown. Cause: %1.” |
Severity | Critical |
Resolution | Check shutdown cause and the Integrated Management Log (IML) for additional information. |
iLOResourceEvents.1.3.BIOSSafeModeEngaged
BIOS Safe Mode is engaged. System will boot in a minimal configuration.
Message Format | “BIOS Safe Mode is engaged. System will boot in a minimal configuration.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.BIOSSafeModeExit
BIOS Safe Mode has successfully booted. System will resume boot in a minimal configuration.
Message Format | “BIOS Safe Mode has successfully booted. System will resume boot in a minimal configuration.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.ComputeOpsManagerConnected
HPE Compute Ops Manager connection status is changed to Connected.
Message Format | “HPE Compute Ops Manager connection status is Connected.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.ComputeOpsManagerConnectionFailed
HPE Compute Ops Manager connection status is changed to Failed.
Message Format | “HPE Compute Ops Manager connection is failed.” |
Severity | Warning |
Resolution | None. |
iLOResourceEvents.1.3.ComputeOpsManagerConnectionInProgress
HPE Compute Ops Manager connection status is changed to In Progress.
Message Format | “HPE Compute Ops Manager connection is in progress.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.ComputeOpsManagerConnectionInitiated
Connection to HPE Compute Ops Manager has been initiated.
Message Format | “Connection to HPE Compute Ops Manager has been initiated by: %1.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.ComputeOpsManagerConnectionNotEnabled
HPE Compute Ops Manager connection status is changed to Not Enabled.
Message Format | “HPE Compute Ops Manager is not Enabled.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.ComputeOpsManagerDisabledByFactoryDefaults
Connection to HPE Compute Ops Manager has been disabled due to Factory defaults.
Message Format | “Connection to HPE Compute Ops Manager has been disabled due to Factory defaults.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.ComputeOpsManagerDisabledBySecureErase
Connection to HPE Compute Ops Manager has been disabled due to secure erase.
Message Format | “Connection to HPE Compute Ops Manager has been disabled due to secure erase by user %1.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.ComputeOpsManagerDisabledByUser
User has disabled connection to HPE Compute Ops Manager.
Message Format | “Connection to HPE Compute Ops Manager has been disabled by User %1.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.DeviceDiscoveryStatusV2
The server device discovery status has changed.
Message Format | “Discovery status is now: AMS: %1, Device Discovery: %2, Smart Array Storage: %3” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.DriveInserted2
The ATA drive has been inserted into the specified location.
Message Format | “The ATA drive has been inserted in location %1 connected to controller in %2.” |
Severity | Warning |
Resolution | None. |
iLOResourceEvents.1.3.DriveRemoved2
The ATA drive has been removed from the specified location.
Message Format | “The ATA drive has been removed from location %1 connected to controller in %2.” |
Severity | Warning |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrLogDrvErasing
The logical drive is currently being erased.
Message Format | “The drive array logical drive %1 on controller located in %2 is currently being erased.” |
Severity | Warning |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrLogDrvExpanding
The logical drive is currently undergoing a transformation.
Message Format | “The drive array logical drive %1 on controller located in %2 is currently undergoing a transformation.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrLogDrvNewLogDrvKeyRekeyRequestReceived
The logical drive is currently encrypted and has received a request to rekey all data with a new logical drive encryption key.The logical drive is online.
Message Format | “The drive array logical drive %1 on controller located in %2 is currently encrypted and has received a request to rekey all data with a new logical drive encryption key.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrLogDrvPredictiveSpareRebuildReady
The logical drive is ready to perform a predictive spare rebuild.
Message Format | “The drive array logical drive %1 on controller located in %2 is ready to perform a predictive spare rebuild.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrLogDrvQueuedForExpansion
The logical drive is ready for transformation.
Message Format | “The drive array logical drive %1 on controller located in %2 is ready for transformation.” |
Severity | Warning |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrLogDrvRapidParityInitializationInProgress
The logical drive is currently undergoing rapid parity initialization.
Message Format | “The drive array logical drive %1 on controller located in %2 is currently undergoing rapid parity initialization.” |
Severity | Warning |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrLogDrvRapidParityInitializationPending
The logical drive is currently pending rapid parity initialization and will be unavailable.
Message Format | “The drive array logical drive %1 on controller located in %2 is currently pending rapid parity initialization and will be unavailable.” |
Severity | Warning |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrLogDrvReadyRebuild
The drive array logical drive is ready for Automatic Data Recovery.
Message Format | “The drive array logical drive %1 on controller located in %2 is ready for Automatic Data Recovery.” |
Severity | Warning |
Resolution | The failed physical drive has been replaced, but the logical drive is still operating in Interim Recovery Mode. |
iLOResourceEvents.1.3.DrvArrLogDrvRebuilding
The drive array logical drive is currently doing Automatic Data Recovery.
Message Format | “The drive array logical drive %1 on controller located in %2 is currently doing Automatic Data Recovery.” |
Severity | Warning |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrLogDrvRekeyInProgress
The logical drive is currently encrypted and all data is currently being rekeyed with a new logical drive key using the background capacity expansion transformation task.
Message Format | “The drive array logical drive %1 on controller located in %2 is currently encrypted and all data is currently being rekeyed with a new logical drive key using the background capacity expansion transformation task.” |
Severity | Warning |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrLogDrvUnconfigured
The drive array logical drive is not configured.
Message Format | “The drive array logical drive %1 on controller located in %2 is not configured.” |
Severity | Critical |
Resolution | Run HPE array configuration utility |
iLOResourceEvents.1.3.DrvArrLogDrvUnencryptedToEncryptedTransformationInProgress
The logical drive is currently being transformed from unencrypted to encrypted and the volume is online.
Message Format | “The drive array logical drive %1 on controller located in %2 is currently being transformed from unencrypted to encrypted and the volume is online.” |
Severity | Warning |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrLogDrvUnencryptedToEncryptedTransformationNotStarted
The logical drive has received a request to transform from unencrypted to encrypted but this process has not yet started.The unencrypted logical drive is currently online.
Message Format | “The drive array logical drive %1 on controller located in %2 has received a request to transform from unencrypted to encrypted but this process has not yet started.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrPhysDrvEraseDone
The drive array physical drive has been erased and is is now in an offline state.
Message Format | “The drive array physical drive at location %1 connected to controller in %2 has been erased and is now in an offline state.” |
Severity | Warning |
Resolution | None |
iLOResourceEvents.1.3.DrvArrPhysDrvEraseQueued
An erase operation is currently queued for the drive array physical drive.
Message Format | “An erase operation is currently queued for the drive array physical drive at location %1 connected to controller in %2.” |
Severity | Warning |
Resolution | None |
iLOResourceEvents.1.3.DrvArrPhysDrvErasing
The drive array physical drive is being erased.
Message Format | “The drive array physical drive at location %1 connected to controller in %2 is being erased.” |
Severity | Warning |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrSpareDriveActive
Automatic Data Recovery is complete.
Message Format | “Drive array spare drive at location %1 connected to controller in %2 has completed Automatic Data Recovery.” |
Severity | OK |
Resolution | None |
iLOResourceEvents.1.3.DrvArrSpareDriveBuilding
A physical drive has failed. Automatic Data Recovery is in progress to recover data to the on-line spare.
Message Format | “Drive array spare drive at location %1 connected to controller in %2 has Automatic Data Recovery in progress.” |
Severity | Critical |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrSpareDriveInactive
An on-line spare is configured, but is not currently in use.
Message Format | “Drive array spare drive at location %1 connected to controller in %2 is configured, but is not currently in use.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrayAccBoardTempDisabled_ExpandInProgress
Write cache operations have been temporarily disabled due to an expand of a logical drive.
Message Format | “Write cache operations for cache module board located in %1 have been temporarily disabled due to an expand of a logical drive.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.DrvArrayAccBoardTempDisabled_SnapshotInProgress
Write cache operations have been temporarily disabled due to a snapshot operation that is queued up or in progress.
Message Format | “Write cache operations for cache module board located in %1 have been temporarily disabled due to a snapshot operation that is queued up or in progress.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.FanInserted
A fault tolerant fan has been inserted into the specified fan location.
Message Format | “The fan has been inserted in fan location %1.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.FanRemoved
A fault tolerant fan has been removed from the specified fan location.
Message Format | “The fan has been removed from fan location %1.” |
Severity | Warning |
Resolution | None. |
iLOResourceEvents.1.3.FansHealthOk
The Fan sub-system is in OK state.
Message Format | “Fan sub-system is OK.” |
Severity | OK |
Resolution | None |
iLOResourceEvents.1.3.FirmwareFlashStatusChanged
The firmware flash status has changed
Message Format | “The firmware flash status is now %1” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.FirmwareIntegrityScanComplete
This event is generated when a firmware integrity issue is found during firmware scan irrespective of a recovery success or failure.
Message Format | “Management Processor completed the firmware integrity scan and detected an anomaly.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.FirmwareRecoveryRequest
This event is generated when firmware recovery is requested.
Message Format | “Firmware recovery is requested.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.IndicatorLEDStateChanged
The state of the indicator LED has changed
Message Format | “The state of the indicator LED is now %1” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.IntelligentDiagnosticsEnabled
Intelligent Diagnostics Enabled: Server will attempt automated recovery.
Message Format | “Intelligent Diagnostics Enabled: Server will attempt automated recovery.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.IntelligentDiagnosticsExit
Intelligent Diagnostics Exit: Automated server recovery has concluded.
Message Format | “Intelligent Diagnostics Exit: Automated server recovery has concluded.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.IntrusionHWInstalled
System intrusion alert hardware is installed.
Message Format | “System intrusion hardware installed.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.IntrusionHWRemoved
System intrusion alert hardware is removed.
Message Format | “System intrusion hardware removed.” |
Severity | OK |
Resolution | There is no action required if the removal of the hardware is expected. If the hardware was not intentionally removed, please verify cable connection. |
iLOResourceEvents.1.3.LiquidCoolingHealthOk
The Liquid-Cooling sub-system is in OK state.
Message Format | “Liquid-Cooling sub-system is OK.” |
Severity | OK |
Resolution | None |
iLOResourceEvents.1.3.MemoryHealthOk
The Memory sub-system is in OK state.
Message Format | “Memory sub-system is OK.” |
Severity | OK |
Resolution | None |
iLOResourceEvents.1.3.NetworkHealthOk
The Network sub-system is in OK state.
Message Format | “Network sub-system is OK.” |
Severity | OK |
Resolution | None |
iLOResourceEvents.1.3.PowerSuppliesHealthOk
The Power Supply sub-system is in OK state.
Message Format | “Power Supply sub-system is OK.” |
Severity | OK |
Resolution | None |
iLOResourceEvents.1.3.PowerSupplyInserted
A fault tolerant power supply has been inserted into the specified bay location.
Message Format | “A power supply has been inserted in bay %1.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.PowerSupplyRemoved
A fault tolerant power supply has been removed from the specified bay location.
Message Format | “A power supply has been removed from bay %1.” |
Severity | Warning |
Resolution | None. |
iLOResourceEvents.1.3.ProcessorsHealthOk
The Processor sub-system is in OK state.
Message Format | “Processor sub-system is OK.” |
Severity | OK |
Resolution | None |
iLOResourceEvents.1.3.RemoteSupportRegistrationComplete
The server was registered to Remote Support.
Message Format | “The server was registered to Remote Support using the %1 method” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.RemoteSupportUnregistrationComplete
The server was unregistered from Remote Support.
Message Format | “The server was unregistered from Remote Support.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.SecurityStateChange
Security state changed.
Message Format | “Security state changed to %1.” |
Severity | OK |
Resolution | No Action |
iLOResourceEvents.1.3.ServerPostComplete
The server has reached Power On Self Test complete.
Message Format | “The server has reached Power On Self Test complete” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.ServerPostDiscoveryComplete
The server has completed device discovery.
Message Format | “The server has completed device discovery.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.ServerPoweredOff
The server has been powered off.
Message Format | “The server has been powered off.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.ServerPoweredOn
The server has been powered on.
Message Format | “The server has been powered on.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.ServerResetDetected
Server Reset Detected. Management Processor firmware has detected a server reset.
Message Format | “Server reset detected.” |
Severity | Warning |
Resolution | Refer to the Integrated Management Log for details on the cause of the server reset. |
iLOResourceEvents.1.3.SmartStorageBatteryHealthOk
The Smart Storage Battery sub-system is in OK state.
Message Format | “Smart Storage Battery sub-system is OK.” |
Severity | OK |
Resolution | None |
iLOResourceEvents.1.3.StorageHealthOk
The Storage sub-system is in OK state.
Message Format | “Storage sub-system is OK.” |
Severity | OK |
Resolution | None |
iLOResourceEvents.1.3.TemperatureHealthOk
The Temperature sub-system is in OK state.
Message Format | “Temperature sub-system is OK.” |
Severity | OK |
Resolution | None |
iLOResourceEvents.1.3.UpdateTaskStateChanged
An update task has changed state.
Message Format | “An update task %1.” |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.iLODriveComponentAdded
A component was added to the iLO Drive.
Message Format | “The component ”%1" was added to the iLO Drive" |
Severity | OK |
Resolution | None. |
iLOResourceEvents.1.3.iLORestServicesStarted
RESTful services started.
Message Format | “RESTful services started. Management Processor Firmware Version: %1, Release date: %2” |
Severity | OK |
Resolution | None. |
NetworkDevice.1.0.CableInserted
Indicates that a network cable has been inserted.
Message Format | “A network cable has been inserted into network adapter ‘%1’ port ‘%2’.” |
Severity | OK |
Resolution | Refresh your cached version of the network port to get the updated information from the service. |
NetworkDevice.1.0.CableRemoved
Indicates that a network cable has been removed.
Message Format | “A cable has been removed from network adapter ‘%1’ port ‘%2’.” |
Severity | OK |
Resolution | Refresh your cached version of the network port to get the updated information from the service. |
NetworkDevice.1.0.ConnectionDropped
Indicates that a network connection has been dropped.
Message Format | “The connection is no longer active for network adapter ‘%1’ port ‘%2’ function ‘%3’.” |
Severity | OK |
Resolution | Refresh your cached version of the network port to get the updated information from the service. |
NetworkDevice.1.0.ConnectionEstablished
Indicates that a network connection has been established.
Message Format | “A network connection has been established for network adapter ‘%1’ port ‘%2’ function ‘%3’.” |
Severity | OK |
Resolution | Refresh your cached version of the network port to get the updated information from the service. |
NetworkDevice.1.0.DegradedConnectionEstablished
Indicates that a network connection has been established, but at an unexpectedly low link speed.
Message Format | “A degraded network connection has been established for network adapter ‘%1’ port ‘%2’ function ‘%3’.” |
Severity | Warning |
Resolution | Refresh your cached version of the network port to get the updated information from the service. |
NetworkDevice.1.0.LinkFlapDetected
Indicates that a network connection is highly unstable.
Message Format | “The network connection for network adapter ‘%1’ port ‘%2’ function ‘%3’ has been established and dropped ‘%4’ times in the last ‘%5’ minutes.” |
Severity | Warning |
Resolution | Contact the network administrator for problem resolution. |
ResourceEvent.1.2.ResourceChanged
Resource updated.
Message Format | “Resource updated.” |
Severity | OK |
Resolution | None. |
ResourceEvent.1.2.ResourceCreated
Resource added.
Message Format | “Resource added.” |
Severity | OK |
Resolution | None. |
ResourceEvent.1.2.ResourceRemoved
Resource removed.
Message Format | “Resource removed.” |
Severity | OK |
Resolution | None. |
ResourceEvent.1.2.ResourceStatusChangedCritical
Resource status changed.
Message Format | “Resource status changed.” |
Severity | OK |
Resolution | None. |
ResourceEvent.1.2.ResourceStatusChangedOK
Resource status changed.
Message Format | “Resource status changed.” |
Severity | OK |
Resolution | None. |
ResourceEvent.1.2.ResourceStatusChangedWarning
Resource status changed.
Message Format | “Resource status changed.” |
Severity | OK |
Resolution | None. |
StorageDevice.1.1.BatteryCharging
A battery charging condition has been detected.
Message Format | “A charging condition for the battery located in ‘%1’ has been detected.” |
Severity | Warning |
Resolution | No action needed. There may be reduced performance and features while the battery is charging. |
StorageDevice.1.1.BatteryFailure
A battery failure condition has been detected.
Message Format | “A failure condition for the battery located in ‘%1’ has been detected.” |
Severity | Critical |
Resolution | Ensure all cables are properly and securely connected. Replace the failed battery. |
StorageDevice.1.1.BatteryMissing
A battery missing condition has been detected.
Message Format | “The battery located in ‘%1’ is missing.” |
Severity | Critical |
Resolution | Attach the battery. Ensure all cables are properly and securely connected. |
StorageDevice.1.1.BatteryOK
The health of a battery has changed to OK.
Message Format | “The health of the battery located in ‘%1’ has changed to OK.” |
Severity | OK |
Resolution | No action needed. |
StorageDevice.1.1.ControllerDegraded
A storage controller degraded condition has been detected.
Message Format | “A degraded condition for the storage controller located in ‘%1’ has been detected due to reason ‘%2’.” |
Severity | Warning |
Resolution | Reseat the storage controller in the PCI slot. Update the controller to the latest firmware version. If the issue persists, replace the controller. |
StorageDevice.1.1.ControllerFailure
A storage controller failure has been detected.
Message Format | “A failure condition for the storage controller located in ‘%1’ has been detected.” |
Severity | Critical |
Resolution | Reseat the storage controller in the PCI slot. Update the controller to the latest firmware version. If the issue persists, replace the controller. |
StorageDevice.1.1.ControllerOK
The storage controller status has changed to OK.
Message Format | “The status of the storage controller located in ‘%1’ has changed to OK.” |
Severity | OK |
Resolution | No action required. |
StorageDevice.1.1.ControllerPasswordAccepted
The storage controller password was entered.
Message Format | “A password was entered for the storage controller located in ‘%1’.” |
Severity | OK |
Resolution | No action required. |
StorageDevice.1.1.ControllerPasswordRequired
The storage controller requires a password.
Message Format | “The storage controller located in ‘%1’ requires a password.” |
Severity | Critical |
Resolution | Enter the controller password. |
StorageDevice.1.1.ControllerPortDegraded
A controller port degraded condition has been detected.
Message Format | “A degraded condition for the controller port located in ‘%1’ has been detected due to reason ‘%2’.” |
Severity | Warning |
Resolution | Ensure all cables are properly and securly connected. Replace faulty cables. |
StorageDevice.1.1.ControllerPortFailure
A controller port failure condition has been detected.
Message Format | “A failure condition for the controller port located in ‘%1’ has been detected.” |
Severity | Critical |
Resolution | Ensure all cables are properly and securly connected. Replace faulty cables. |
StorageDevice.1.1.ControllerPortOK
The health of a controller port has changed to OK.
Message Format | “The health of the controller port located in ‘%1’ has changed to OK.” |
Severity | OK |
Resolution | No action needed. |
StorageDevice.1.1.ControllerPreviousError
A storage controller error has been detected prior to reboot.
Message Format | “A previous error condition for the storage controller located in ‘%1’ has been detected due to ‘%2’.” |
Severity | Warning |
Resolution | Update the controller to the latest firmware version. If the issue persists, replace the controller. |
StorageDevice.1.1.DriveFailure
A drive failure condition has been detected.
Message Format | “A failure condition for the drive located in ‘%1’ has been detected.” |
Severity | Critical |
Resolution | Ensure all cables are properly and securely connected. Ensure all drives are fully seated. Replace the defective cables, drive, or both. |
StorageDevice.1.1.DriveFailureCleared
A previously detected failure condition on a drive has been cleared.
Message Format | “A failure condition for the drive located in ‘%1’ has been cleared.” |
Severity | OK |
Resolution | No action needed. |
StorageDevice.1.1.DriveInserted
A drive has been inserted.
Message Format | “The drive located at ‘%1’ was inserted.” |
Severity | OK |
Resolution | If the drive is not properly displayed, attempt to refresh the cached data. |
StorageDevice.1.1.DriveMissing
A drive missing condition has been detected.
Message Format | “A missing condition for the drive located in ‘%1’ has been detected.” |
Severity | Critical |
Resolution | Ensure all cables are properly and securely connected. Ensure all drives are fully seated. Replace the defective cables, drive, or both. Delete the volume if no longer needed. |
StorageDevice.1.1.DriveMissingCleared
A previous drive missing condition has been cleared.
Message Format | “A missing condition for the drive located in ‘%1’ has been cleared.” |
Severity | OK |
Resolution | No action needed. |
StorageDevice.1.1.DriveOK
The status of a physical drive has changed to OK.
Message Format | “The status of the drive located in ‘%1’ has changed to OK.” |
Severity | OK |
Resolution | No action needed. |
StorageDevice.1.1.DriveOffline
A drive offline condition has been detected.
Message Format | “An offline condition for the the drive located in ‘%1’ has been detected.” |
Severity | Critical |
Resolution | If the drive is unconfigured or needs an import, configure the drive. If the drive operation is in progress, wait for the operation to complete. If the drive is not supported, replace it. |
StorageDevice.1.1.DriveOfflineCleared
A drive offline condition has been cleared.
Message Format | “An offline condition for the the drive located in ‘%1’ has been cleared.” |
Severity | OK |
Resolution | No action needed. |
StorageDevice.1.1.DrivePredictiveFailure
A predictive drive failure condition has been detected.
Message Format | “A predictive failure condition for the drive located in ‘%1’ has been detected.” |
Severity | Warning |
Resolution | If this drive is not part of a fault-tolerant volume, first back up all data, then replace the drive and restore all data afterward. If this drive is part of a fault-tolerant volume, replace this drive as soon as possible as long as the volume status is OK. |
StorageDevice.1.1.DrivePredictiveFailureCleared
A previously detected predictive failure condition on a drive has been cleared.
Message Format | “A predictive failure condition for the drive located in ‘%1’ has been cleared.” |
Severity | OK |
Resolution | No action needed. |
StorageDevice.1.1.DriveRemoved
A drive has been removed.
Message Format | “The drive located in ‘%1’ was removed.” |
Severity | Critical |
Resolution | If the drive is still displayed, attempt to refresh the cached data. |
StorageDevice.1.1.VolumeDegraded
The storage controller has detected a degraded volume condition.
Message Format | “The volume ‘%1’ attached to the storage controller located in ‘%2’ is in degraded state.” |
Severity | Warning |
Resolution | Ensure all cables are properly and securely connected. Replace failed drives. |
StorageDevice.1.1.VolumeFailure
The storage controller has detected a failed volume condition.
Message Format | “The volume ‘%1’ attached to the storage controller located in ‘%2’ has failed.” |
Severity | Critical |
Resolution | Ensure all cables are properly and securely connected. Ensure all drives are fully seated and operational. |
StorageDevice.1.1.VolumeOK
A volume status has changed to OK.
Message Format | “The status of volume ‘%1’ that is attached to the storage controller located in ‘%2’ has changed to OK.” |
Severity | OK |
Resolution | No action needed. |
StorageDevice.1.1.VolumeOffline
The storage controller has detected an offline volume condition.
Message Format | “The volume ‘%1’ attached to the storage controller located in ‘%2’ is offline.” |
Severity | Critical |
Resolution | Use storage sofware to enable, repair, or import the volume. You may also delete or move volume back to the original controller. |
StorageDevice.1.1.VolumeOfflineCleared
The storage controller has detected an online volume condition.
Message Format | “The volume ‘%1’ attached to the storage controller located in ‘%2’ is online.” |
Severity | OK |
Resolution | No action needed. |
StorageDevice.1.1.WriteCacheDataLoss
The write cache is reporting loss of data in posted-writes memory.
Message Format | “The write cache on the storage controller located in ‘%1’ has data loss.” |
Severity | Critical |
Resolution | Check the controller resource properties to determine cause of the write cache data loss. |
StorageDevice.1.1.WriteCacheDegraded
The write cache state is degraded.
Message Format | “The write cache state on the storage controller located in ‘%1’ is degraded.” |
Severity | Critical |
Resolution | Check the controller to determine the cause of write cache degraded state, such as a missing battery or hardware failure. |
StorageDevice.1.1.WriteCacheProtected
A storage controller write cache state is in protected mode.
Message Format | “The write cache state on the storage controller located in ‘%1’ is in protected mode.” |
Severity | OK |
Resolution | No action needed. |
StorageDevice.1.1.WriteCacheTemporarilyDegraded
The write cache state is temporarily degraded.
Message Format | “The write cache state on the storage controller located in ‘%1’ is temporarily degraded.” |
Severity | Warning |
Resolution | Check the controller to determine the cause of write cache temporarily degraded state, such as a battery is charging or a data recovery rebuild operation is pending. |
TaskEvent.1.0.TaskAborted
The task with id %1 has been aborted.
Message Format | “The task with id %1 has been aborted.” |
Severity | Critical |
Resolution | None. |
TaskEvent.1.0.TaskCancelled
The task with id %1 has been cancelled.
Message Format | “The task with id %1 has been cancelled.” |
Severity | Warning |
Resolution | None. |
TaskEvent.1.0.TaskCompletedOK
The task with id %1 has completed.
Message Format | “The task with id %1 has completed.” |
Severity | OK |
Resolution | None. |
TaskEvent.1.0.TaskCompletedWarning
The task with id %1 has completed with warnings.
Message Format | “The task with id %1 has completed with warnings.” |
Severity | Warning |
Resolution | None. |
TaskEvent.1.0.TaskPaused
The task with id %1 has been paused.
Message Format | “The task with id %1 has been paused.” |
Severity | Warning |
Resolution | None. |
TaskEvent.1.0.TaskProgessChanged
The task with id %1 has changed to progress %2 percent complete.
Message Format | “The task with id %1 has changed to progress %2 percent complete.” |
Severity | OK |
Resolution | None. |
TaskEvent.1.0.TaskRemoved
The task with id %1 has been removed.
Message Format | “The task with id %1 has been removed.” |
Severity | Warning |
Resolution | None. |
TaskEvent.1.0.TaskResumed
The task with id %1 has been resumed.
Message Format | “The task with id %1 has been resumed.” |
Severity | OK |
Resolution | None. |
TaskEvent.1.0.TaskStarted
The task with id %1 has started.
Message Format | “The task with id %1 has started.” |
Severity | OK |
Resolution | None. |